HomeMy WebLinkAboutZ-9259 Staff AnalysisFILE NO.: Z-9259
NAME: 9025 South Heights Road Short -form PD-R
LOCATION: Located at 9025 South Heights Road
DEVELOPER:
Manuel Beaz-Beaz
13743 Appleglenn Cove
Alexander, AR 72002
SURVEYOR/ENGINEER:
Laha Engineering, Inc.
6602 Baseline Road, Suite E
Little Rock, AR 72209
AREA: 0.39 acres
WARD: 2
CURRENT ZONING
ALLOWED USES:
PROPOSED ZONING
PROPOSED USE:
VARIANCE/WAIVERS
NUMBER OF LOTS: 1
PLANNING DISTRICT: 14
R-2, Single-family
Single-family residential
-m
One (1) duplex unit
None requested.
A. PROPOSAL/REQUEST/APPLICANT'S STATEMENT:
FT. NEW STREET: 0 LF
ENSUS TRACT: 41.08
The applicant is proposing a rezoning of the site from R-2, Single-family to PD-R,
Planned Development Residential, to allow the construction of one (1) duplex
building on the site. The applicant is proposing the placement of ten (10) parking
spaces along South Heights Road. The plan includes an area of open space along
the western property line.
FILE NO.: Z-9259 (Cont.
B. EXISTING CONDITIONS:
The site is located on South Heights Road, a residential street which was
developed prior to the area being annexed into the City limits of the City of Little
Rock. There is no curb, gutter or sidewalk in place along this street. The area
around this lot is developed with single-family homes. There is a large
manufactured home park located to the south of this site which is also accessed
by South Heights Road.
C. NEIGHBORHOOD COMMENTS:
All property owners located within 200-feet of the site along with the Upper
Baseline Neighborhood Association and Southwest Little Rock United for Progress
were notified of the public hearing.
D. ENGINEERING COMMENTS:
PUBLIC WORKS CONDITION
1. Due to the proposed use of the property, the Master Street Plan specifies that
South Heights Road for the frontage of this property must meet commercial
street standards. Dedicate right-of-way to 30 feet from centerline.
2. With site development, provide the design of street conforming to the Master
Street Plan. Construct one-half street improvement to South Heights Road
including 5-foot sidewalks with the planned development. The new back of
curb should be located 15.5 feet from centerline.
3. Plans of all work in right-of-way shall be submitted for approval prior to start of
work. Obtain barricade permit prior to doing any work in the right-of-way from
Traffic Engineering, Travis Herbner, 501.379.1805 or therbner(c iRtlerock.gov.
4. Provide a Sketch Grading and Drainage Plan per Section 29-186 (e).
5. A grading permit in accordance with Section 29-186 (c) and (d) will be required
prior to any land clearing or grading activities at the site. Other than residential
subdivisions, site grading and drainage plans must be submitted and approved
prior to the start of construction.
6. Stormwater detention will not apply to the proposed development.
7. Hauling of fill material on or off site over municipal streets and roads requires
approval prior to a grading permit being issued. Contact Public Works Traffic
Engineering, Travis Herbner, 501.379.1805 or therbner littlerock. ov for more
information.
8. Damage to public and private property due to hauling operations or operation
of construction related equipment from a nearby construction site shall be
repaired by the responsible party prior to issuance of a certificate of occupancy.
9. All driveways shall be concrete aprons per City Ordinance.
2
FILE NO.: Z-9259 (Cont.)
E. Utilities/Fire Department/Parks/County Planning:
Little Rock Water Reclamation Authority Sewer available to this site. Separate
service required for each building. Contact Little Rock Water Reclamation
Authority for additional information.
Entergy: Entergy does not object to this proposal. There do not appear to be any
conflicts with existing electrical utilities based on the information provided. There
is an existing single phase power line running along the east side of South Heights
Road which would be used to feed the proposed development. Contact Entergy
in advance to discuss electrical service requirements, or adjustments to existing
facilities (if any) as this project proceeds.
Centerpoint Energy: No comment received.
AT & T: No comment received.
Central Arkansas Water:
1. All Central Arkansas Water requirements in effect at the time of request for
water service must be met.
2. Please submit plans for water facilities and/or fire protection system to Central
Arkansas Water for review. Plan revisions may be required after additional
review. Contact Central Arkansas Water regarding procedures for installation
of water facilities and/or fire service. Approval of plans by the Arkansas
Department of Health Engineering Division and the Little Rock Fire Department
is required.
3. The facilities on -site will be private. When meters are planned off private lines,
private facilities shall be installed to Central Arkansas Water's materials and
construction specifications and installation will be inspected by an engineer,
licensed to practice in the State of Arkansas. Execution of a Customer Owned
Line Agreement is required.
4. Due to the nature of this facility, installation of an approved reduced pressure
zone backflow preventer assembly (RPZA) is required on the domestic water
service. This assembly must be installed prior to the first point of use. Central
Arkansas Water requires that upon installation of the RPZA, successful tests
of the assembly must be completed by a Certified Assembly Tester licensed by
the State of Arkansas and approved by Central Arkansas Water. The test
results must be sent to Central Arkansas Water's Cross Connection Section
within ten days of installation and annually thereafter. Contact the Cross
Connection Section at 501.377.1226 if you would like to discuss backflow
prevention requirements for this project.
5. Fire sprinkler systems which do not contain additives such as antifreeze shall
be isolated with a double detector check valve assembly. If additives are used,
a reduced pressure zone back flow preventer shall be required.
K
FILE NO.: Z-9259 Cont.
Fire Department:
1. Fire Hydrants. Maintain fire apparatus access roads at fire hydrant locations
as per Appendix D of the 2012 Arkansas Fire Prevention Code Vol. 1 Section
D103.1 Access road width with a hydrant. Where a fire hydrant is located on a
fire apparatus access road, the minimum road width shall be 26 feet, exclusive
of shoulders.
2. Grade. Maintain fire apparatus access roads as per Appendix D of the
2012 Arkansas Fire Prevention Code Vol. 1 Section D103.2 Grade. Fire
apparatus access roads shall not exceed 10 percent in grade except as
approved by the fire chief.
3. Loading. Maintain fire apparatus access road design as per Appendix D of the
2012 Arkansas Fire Prevention Code Vol. 1 Section D102.1 Access and
loading. Facilities, buildings or portions of buildings hereafter constructed shall
be accessible to fire department apparatus by way of an approved fire
apparatus access road with an asphalt, concrete or other approved driving
surface capable of supporting the imposed load of fire apparatus weighing at
least 75,000 pounds.
4. Dead Ends. Maintain fire apparatus access roads at dead end locations as per
Appendix D of the 2012 Arkansas Fire Prevention Code Vol. 1 Section D103.4
Dead Ends. Dead-end fire apparatus access roads in excess of
150 feet shall be provided with width and turnaround provisions in accordance
with Table D103.4. Requirements for Dead-end fire apparatus access roads.
1. Electric gate operators, where provided, shall be listed in accordance
with U L 325.
2. Gates, intended for automatic operation shall be designed, constructed
and installed to comply with requirements of ASTM F 2200.
5. One- or Two -Family Residential Developments. As per Appendix D, Section
D107.1 of the Arkansas Fire Prevention Code Vol. 1, One- or Two -Family
dwelling residential developments. Developments of one- or two-family
dwellings where the number of dwelling units exceeds 30 shall be provided with
two separate and approved fire apparatus access roads, and shall meet the
requirements of Section D104.3.
1. Exceptions: Where there are more than 30 dwelling units on a single public
or private fire apparatus access road and al dwelling units are equipped
throughout with an approved automatic sprinkler system in accordance with
Section 903.3.1.1, 903.3.1.2 or 903.3.1.3 of the Arkansas Fire Code, access
from two directions shall not be required.
2. The number of dwelling units on a single fire apparatus access road shall
not be increased unless fire apparatus access roads will connect with future
development, as determined by the fire code official.
6. Fire Hydrants. Locate Fire Hydrants as per Appendix C of the
2012 Arkansas Fire Prevention Code. Section C101 — C105, in conjunction with
Central Arkansas Water (Jason Lowder 501.377.1245) and the
FILE NO.: Z-9259 [Cont.
Little Rock Fire Marshal's Office (Capt. Tony Rhodes 501.918.3757 or
Capt. John Hogue 501.918.3754). Number and Distribution of Fire Hydrants as
per Table C105.1.
Parks and Recreation: No comment received.
CountV Planning: No comment.
F. Building Codes/Landscape-
Building Code: No comment.
Landscape:
1. Site plan must comply with the City's landscape and buffer ordinance
requirements.
2. Street buffers will be required at six (6) percent of the average depth of the lot.
The minimum dimension shall be one-half ('/2) the full width requirement but in
no case less than nine (9) feet. A minimum eighteen (18) foot wide buffer is
required adjacent to the South Heights Road right-of-way.
3. Screening requirements will need to be met for the vehicular use areas
adjacent to street right-of-ways. Provide screening shrubs with an average
linear spacing of not less at three (3) feet within the required landscape area.
Provide trees with an average linear spacing of not less than thirty (30) feet.
4. A land use buffer will be required when an adjacent property has a dissimilar
use of a more restrictive nature. Requirements for landscaping in land use
buffers shall be the same as perimeter landscaping. As a component of all land
use buffer requirements, opaque screening, whether a fence or other device, a
minimum of six (6) feet in height shall be required upon the property line side
of the buffer.
5. A perimeter planting strip is required along any side of a vehicular use area that
abuts adjoining property or the right-of-way of any street. This strip shall be at
least nine (9) feet wide. One (1) tree and three (3) shrubs or vines shall be
planted for every thirty (30) linear feet of perimeter planting strip. Perimeter
planting strips as indicated are deficient.
6. The City Beautiful Commission recommends preserving as many existing trees
as feasible on this site. Credit toward fulfilling Landscape Ordinance
requirements can be given when preserving trees of six (6) inch caliper
or larger.
G. Transportation/Planning:
Rock Region Metro: Location is served by METRO on Route 23 Baseline, a high
ridership route. We recommend providing a sidewalk for access to the transit route.
61
FILE NO.: Z-9259 Cont.)
Planning Division:_ This request is located in Geyer Springs East Planning District.
The Land Use Plan shows Residential Low Density (RL) for this property. The
Residential Low Density category provides for single family homes at densities not
to exceed six (6) units per acre. Such residential development is typically
characterized by conventional single family homes, but may include patio or
garden homes and cluster homes, provided that the density remain less than six
(6) units per acre. The applicant has applied for a rezoning from R-2 (Single Family
District) to PD-R (Planned Development Residential) to allow new construction of
a duplex at this location.
Master Street Plan: West of the property is South Heights Road and it is shown as
a Local Street on the Master Street Plan. The primary function of Local Streets is
to provide access to adjacent properties. Local Streets that are abutted by
non-residential zoning/use or more intensive zoning than duplexes are considered
as "Commercial Streets". A Collector design standard is used for Commercial
Streets. This street may require dedication of right-of-way and may require street
improvements for entrances and exits to the site.
Bicycle Plan: There are no bike routes shown in the immediate vicinity.
H. SUBDIVISION COMMITTEE COMMENT: (September 20, 2017)
The applicant was present representing the request. Staff stated there were few
outstanding technical issues in need of addressing related to the site plan. Staff
requested details concerning any proposed fences. Staff also requested details
concerning any proposed signage.
Public Works comments were addressed. Staff stated a dedication of right of way
to 30-feet from centerline was required along South Heights Road. Staff stated a
grading permit was required prior to any land development of the site. Staff stated
the City's stormwater detention ordinance would apply to the development of the
site. Staff stated all driveways were to be concrete aprons per City ordinance.
Landscaping comments were addressed. Staff stated a perimeter landscape strip
was required along the parking lot edges. Staff stated in addition a minimum street
buffer of nine (9) feet would be required. Staff stated screening was require along
the northern and southern perimeters of the site.
Staff noted the comments from the various other departments and agencies. Staff
suggested the applicant contact the departments or agencies directly with any
questions or concerns. There were no more issues for discussion. The Committee
then forwarded the item to the full Commission for final action.
ANALYSIS:
The applicant submitted a revised site plan to staff addressing the technical issues
associated with the request raised at the September 20, 2017, Subdivision
Committee meeting. The applicant has removed a previously proposed rear unit
R
FILE NO.: Z-9259
and is now proposing to place a single duplex unit on the site. This removes from
the staff comments the requirement for street widening. Right of way dedication
will still be required.
The applicant is proposing a rezoning of the site from R-2, Single-family to PD-R,
Planned Development Residential, to allow the construction of one (1) duplex
building on the site.
The applicant is proposing the placement of ten (10) parking spaces along South
Heights Road. Parking for one (1) and two (2) family developments is based on
one and one-half (1 Y2) parking spaces per unit. Three (3) parking spaces would
typically be required for the duplex. Staff does not feel the site requires the number
of parking spaces as proposed. Staff feels the parking should be reduced to no
more than six (6) parking spaces.
The plan indicates the placement of a landscape strip along the northern and
southern perimeters of 8.5-feet. The landscape ordinance would typically require
the placement of a landscape strip along these perimeters of nine (9) feet. The
ordinance does allow for a transfer of a portion of the landscape area to other parts
of the site if the area is available. The plan includes an area of open space along
the western property line.
The plan does not include the placement of the required street buffer. The plan as
presented has more than adequate parking to serve the development of a duplex
unit. Staff recommends one (1) of the parking spaces be removed along South
Heights Road to allow for the proper street buffering.
Staff is supportive of the applicant's request. Based on the current plan for
one (1) duplex building staff feels there will be adequate area of outdoor living
space and staff also feels the one (1) building is more in keeping with the character
of the neighborhood.
AFF RECOMMENDATION:
Staff recommends approval of the request subject to compliance with the
comments and conditions as outlined in paragraphs D, E and F of the agenda staff
report.
Staff recommends there be no more than six (6) parking to serve the site and to
allow for the proper street buffering.
PLANNING COMMISSION ACTION:
(OCTOBER 12, 2017)
The applicant was present. There were no registered objectors present. Staff presented
the item with a recommendation of approval of the request subject to compliance with the
comments and conditions as outlined in paragraphs D, E and F of the agenda staff report.
Staff presented a recommendation there be no more than six (6) parking spaces to serve
7
FILE NO.: Z-9259
the site and to allow for the proper street buffering. There was no further discussion. The
item was placed on the consent agenda and approved as recommended by staff by a
vote of 8 ayes, 0 noes, 2 absent and 1 recusal (Commissioner Laha).
ITEM NO.: 12.
NAME: 9025 South Heights Road Short -form PD-R
LOCATION: located at 9025 South Heights Road
Plannina Staff Comments:
Z-9259
1. Provide notification of all property owners located within 200-feet of the site including the
certified abstract list, notice form with affidavit executed and proof of mailing. The notice
must be mailed no later than September 27, 2017. The Office of Planning and
Development must receive the proof of notice no later than October 6, 2017.
2. Provide details of the proposed fencing plan. Include the location, the total height, and
construction materials proposed for fences.
3. Will the development have an identification sign? If so note the location of the proposed
sign on the site plan and include the total height and area for the proposed signage.
4. The lot is 57-feet wide which would allow the placement of 8.5-feet of landscaping along
the edges of the parking lot. The plan has indicated indicates a 6-feet landscape strip.
Staff suggest the plan be redesigned to allow 40-feet of pavement and the landscape
strips of 8.5-feet.
5. Will there be a dumpster located on the site? If so note the location and provide the days
and hours of dumpster service.
Variance/Waivers: None requested.
Engineering Comments:
Public Works Conditions:
1. Due to the proposed use of the property, the Master Street Plan specifies that South
Heights Road for the frontage of this property must meet commercial street standards.
Dedicate right-of-way to 30 feet from centerline.
2. With site development, provide the design of street conforming to the Master Street Plan.
Construct one-half street improvement to South Heights Road including 5-foot sidewalks
with the planned development. The new back of curb should be located 15.5 feet from
centerline.
3. Plans of all work in right-of-way shall be submitted for approval prior to start of work.
Obtain barricade permit prior to doing any work in the right-of-way from Traffic
Engineering, Travis Herbner, 501.379.1805 or therbner littlerock. ov.
4. Provide a Sketch Grading and Drainage Plan per Section 29-186 (e).
5. A grading permit in accordance with Section 29-186 (c) and (d) will be required prior to
any land clearing or grading activities at the site. Other than residential subdivisions, site
grading and drainage plans must be submitted and approved prior to the start of
construction.
6. Stormwater detention will not apply to the proposed development.
7. Hauling of fill material on or off site over municipal streets and roads requires approval
ITEM NO.: 12. Z-9259
prior to a grading permit being issued. Contact Public Works Traffic Engineering, Travis
Herbner, 501.379.1805 or therbner&littlerock.gov for more information.
8. Damage to public and private property due to hauling operations or operation of
construction related equipment from a nearby construction site shall be repaired by the
responsible party prior to issuance of a certificate of occupancy.
9. All driveways shall be concrete aprons per City Ordinance.
Utilities/Fire Department/Parks/County Planning:
Little Rock Water Reclamation Authority: Sewer available to this site. Separate service
required for each building. Contact Little Rock Water Reclamation Authority for additional
information.
Entergy: Entergy does not object to this proposal. There do not appear to be any conflicts
with existing electrical utilities based on the information provided. There is an existing single
phase power line running along the east side of South Heights Road which would be used to
feed the proposed development. Contact Entergy in advance to discuss electrical service
requirements, or adjustments to existing facilities (if any) as this project proceeds.
Centerpoint Energy: No comment received.
AT & T: No comment received.
Central Arkansas Water:
1. All Central Arkansas Water requirements in effect at the time of request for water service
must be met.
2. Please submit plans for water facilities and/or fire protection system to Central Arkansas
Water for review. Plan revisions may be required after additional review. Contact Central
Arkansas Water regarding procedures for installation of water facilities and/or fire service.
Approval of plans by the Arkansas Department of Health Engineering Division and the
Little Rock Fire Department is required.
3. The facilities on -site will be private. When meters are planned off private lines, private
facilities shall be installed to Central Arkansas Water's materials and construction
specifications and installation will be inspected by an engineer, licensed to practice in the
State of Arkansas. Execution of a Customer Owned Line Agreement is required.
4. Due to the nature of this facility, installation of an approved reduced pressure zone
backflow preventer assembly (RPZA) is required on the domestic water service. This
assembly must be installed prior to the first point of use. Central Arkansas Water requires
that upon installation of the RPZA, successful tests of the assembly must be completed by
a Certified Assembly Tester licensed by the State of Arkansas and approved by Central
Arkansas Water. The test results must be sent to Central Arkansas Water's Cross
Connection Section within ten days of installation and annually thereafter. Contact the
Cross Connection Section at 501.377.1226 if you would like to discuss backflow
prevention requirements for this project.
ITEM NO.: 12,
Z-9259
5. Fire sprinkler systems which do not contain additives such as antifreeze shall be isolated
with a double detector check valve assembly. If additives are used, a reduced pressure
zone back flow preventer shall be required.
Fire Department:
1. Fire Hydrants. Maintain fire apparatus access roads at fire hydrant locations as per
Appendix D of the 2012 Arkansas Fire Prevention Code Vol. 1 Section D103.1 Access
road width with a hydrant. Where a fire hydrant is located on a fire apparatus access road,
the minimum road width shall be 26 feet, exclusive of shoulders.
2. Grade. Maintain fire apparatus access roads as per Appendix D of the 2012 Arkansas
Fire Prevention Code Vol. 1 Section D103.2 Grade. Fire apparatus access roads shall not
exceed 10 percent in grade except as approved by the fire chief.
3. Loading, Maintain fire apparatus access road design as per Appendix D of the 2012
Arkansas Fire Prevention Code Vol. 1 Section D102.1 Access and loading. Facilities,
buildings or portions of buildings hereafter constructed shall be accessible to fire
department apparatus by way of an approved fire apparatus access road with an asphalt,
concrete or other approved driving surface capable of supporting the imposed load of fire
apparatus weighing at least 75,000 pounds.
4. Dead Ends. Maintain fire apparatus access roads at dead end locations as per Appendix
D of the 2012 Arkansas Fire Prevention Code Vol. 1 Section D103.4 Dead Ends. Dead-
end fire apparatus access roads in excess of 150 feet shall be provided with width and
turnaround provisions in accordance with Table D103.4. Requirements for Dead-end fire
apparatus access roads.
1. Electric gate operators, where provided, shall be listed in accordance with UL 325.
2. Gates, intended for automatic operation shall be designed, constructed and
installed to comply with requirements of ASTM F 2200.
5. One- or Two -Family Residential Developments. As per Appendix D, Section D107.1 of the
Arkansas Fire Prevention Code Vol. 1, One- or Two -Family dwelling residential
developments. Developments of one- or two-family dwellings where the number of
dwelling units exceeds 30 shall be provided with two separate and approved fire
apparatus access roads, and shall meet the requirements of Section D104.3.
1. Exceptions: Where there are more than 30 dwelling units on a single public or private
fire apparatus access road and al dwelling units are equipped throughout with an
approved automatic sprinkler system in accordance with Section 903.3.1.1, 903.3.1.2
or 903.3.1.3 of the Arkansas Fire Code, access from two directions shall not be
required.
2. The number of dwelling units on a single fire apparatus access road shall not be
increased unless fire apparatus access roads will connect with future development, as
determined by the fire code official.
6. Fire Hydrants. Locate Fire Hydrants as per Appendix C of the 2012 Arkansas Fire
Prevention Code. Section C101 — C105, in conjunction with Central Arkansas Water
3
ITEM NO.: 12.
Z-9259
(Jason Lowder 501.377.1245) and
Rhodes 501.918.3757 or Capt. John
Fire Hydrants as per Table C105.1.
the Little Rock Fire Marshal's Office (Capt. Tony
Hogue 501.918.3754). Number and Distribution of
Parks and Recreation: No comment received.
County Planning: No comment.
Building Codes/Landscape:
Building Code: No comment.
Landscape:
1. Site plan must comply with the City's landscape and buffer ordinance requirements.
2. Street buffers will be required at six (6) percent of the average depth of the lot. The
minimum dimension shall be one-half (Y2) the full width requirement but in no case less
than nine (9) feet. A minimum eighteen (18) foot wide buffer is required adjacent to the
South Heights Road right-of-way.
3. Screening requirements will need to be met for the vehicular use areas adjacent to street
right-of-ways. Provide screening shrubs with an average linear spacing of not less at three
(3) feet within the required landscape area. Provide trees with an average linear spacing
of not less than thirty (30) feet.
4. A land use buffer will be required when an adjacent property has a dissimilar use of a
more restrictive nature. Requirements for landscaping in land use buffers shall be the
same as perimeter landscaping. As a component of all land use buffer requirements,
opaque screening, whether a fence or other device, a minimum of six (6) feet in height
shall be required upon the property line side of the buffer.
5. A perimeter planting strip is required along any side of a vehicular use area that abuts
adjoining property or the right-of-way of any street. This strip shall be at least nine (9) feet
wide. One (1) tree and three (3) shrubs or vines shall be planted for every thirty (30) linear
feet of perimeter planting strip. Perimeter planting strips as indicated are deficient.
6. The City Beautiful Commission recommends preserving as many existing trees as
feasible on this site. Credit toward fulfilling Landscape Ordinance requirements can be
given when preserving trees of six (6) inch caliper or larger.
TransportationlPlan nine:
Rock Region Metro: Location is served by METRO on Route 23 Baseline, a high ridership
route. We recommend providing a sidewalk for access to the transit route.
Planninq Division: This request is located in Geyer Springs East Planning District. The Land
Use Plan shows Residential Low Density (RL) for this property. The Residential Low Density
category provides for single family homes at densities not to exceed six (6) units per acre.
Such residential development is typically characterized by conventional single family homes,
4
ITEM NO.: 12. Z-9259
but may include patio or garden homes and cluster homes, provided that the density remain
less than six (6) units per acre. The applicant has applied for a rezoning from R-2 (Single
Family District) to PD-R (Planned Development Residential) to allow new construction of two
(2) duplexes at this location.
Master Street Plan: West of the property is South Heights Road and it is shown as a Local
Street on the Master Street Plan. The primary function of Local Streets is to provide access to
adjacent properties. Local Streets that are abutted by non-residential zoning/use or more
intensive zoning than duplexes are considered as "Commercial Streets". A Collector design
standard is used for Commercial Streets. This street may require dedication of right-of-way
and may require street improvements for entrances and exits to the site.
Bicycle Plan: There are no bike routes shown in the immediate vicinity.
Revised plat/plan: Submit four (4) copies of a revised preliminary plat/plan (to include the
additional information as noted above) to staff on Wednesday, September 27, 2017.