HomeMy WebLinkAboutZ-9257 Staff AnalysisFILE NO.: Z-9257
NAME: Big Rock Plaza Long -form PCD
LOCATION: Located on the Northwest corner of Pleasant Hill Road and
Vimy Ridge Road
DEVELOPER:
Big Rock Development
12506 Vimy Ridge Road
Alexander, AR 72002
FNC;INFFR-
Big Rock Development
12506 Vimy Ridge Road
Alexander, AR 72002
AREA: 23.26 acres
CURRENT ZONING
ALLOWED USES
PROPOSED ZONING
PROPOSED USE
VARIANCEM/AIVERS
NUMBER OF LOTS: 5
PLANNING DISTRICT: 16
R-2, Single-family
Single-family residential
FT. NEW STREET: 1,400 LF
CENSUS TRACT: 41.04
PCD, Planned Commercial Development
Mixed use — Retail, Office and Elderly Housing
None requested.
A. PROPOSAL/REQUEST/APPLICANT'S STATEMENT:
The applicant is seeking approval of a rezoning from R-2, Single-family to PCD,
Planned Commercial Development, to allow the development of the site as a mixed
use development. The applicant is proposing a five (5) lot subdivision. Lot 1 is
proposed containing 2.66-acres. Lot 1 is proposed for development with a
16,000 square foot retail building utilizing C-3, General Commercial District uses.
Lot 2 is proposed containing 6.09-acres developed with a 43,600 square foot
building. The lot is proposed utilizing C-3, General Commercial District uses
FILE NO.: Z-9257 (Cont.
and/or a grocery store. Lot 3 is proposed containing 2.76-acres. The lot is
proposed with a 30,000 square foot four (4) bay retail strip center utilizing C-3,
General Commercial District uses. Lot 4 is proposed containing 4.31-acres
developed with a 46,000 square foot assistance living center. Lot 5 is proposed
containing 7.7-acres. The development plan for Lot 5 consist of 35 buildings,
100-feet by 20-feet, of mini -warehouse.
The development is proposed with a new public street. The street is proposed with
a back of curb to back of curb width of 51-feet. The street is proposed as a divided
median street.
B. EXISTING CONDITIO
The site is a tree covered site with frontage on Pleasant Hill Road and Vimy Ridge
Road. Both streets are substandard streets with no curb, gutter or sidewalk in
place and open ditches for drainage. The area to the south of this site is
predominately single-family homes located on large lots. The area to the north
is developing as an attached residential community by this developer.
C. NEIGHBORHOOD COMMENT
All property owners located within 200-feet of the site along with the Alexander
Road Neighborhood Association, the Quail Run Neighborhood Association and
Southwest Little Rock United for Progress were notified of the public hearing.
D. ENGINEERING COMMENTS:
PUBLIC WORKS CONDITIONS:
1. Vimy Ridge Road is classified on the Master Street Plan as a minor arterial.
A dedication of right-of-way 45 feet from centerline will be required.
2. Pleasant Hill Road is classified on the Master Street Plan as a collector street.
A dedication of right-of-way 30 feet from centerline will be required. (Unless
the collector street is moved to the north through this proposed development.)
3. The proposed commercial street should be constructed within a 60 foot wide
right-of-way and 36 feet width from back of curb to back of curb with sidewalks
on both sides and access ramps at intersections. The proposed median
lengths may be altered from approved plans to provide sufficient left turn lane
stack depending on estimated traffic generation from the adjacent
development.
4. A 20 foot radial dedication of right-of-way is required at the intersection of
Vimy Ridge Road and Pleasant Hill Road.
5. With site development, provide the design of street conforming to the Master
Street Plan. Construct one-half street improvement to Vimy Ridge Road
including 5-foot sidewalks with the planned development. The new back of
curb should be located 29.5 feet from centerline. The proposed sidewalk may
2
FILE NO.. Z-9257 Cont.
be required to be placed on the north side of the Centerpoint gas pipeline
station. A left turn lane should be provided on north bound Vimy Ridge Road.
6. With site development, provide the design of street conforming to the Master
Street Plan. Construct one-half street improvement to Pleasant Hill Road
including 5-foot sidewalks with the planned development. The new back of
curb should located 13 feet from centerline of the existing street. The new
sidewalk maybe required to be placed on the north and west sides of the
Centerpoint gas pipeline
7. A grading permit in accordance with Section 29-186 (c) and (d) will be
required prior to any land clearing or grading activities at the site. Other than
residential subdivisions, site grading and drainage plans must be submitted
and approved prior to the start of construction. Is a variance being requested
to advance grade the lots with the construction of the street?
8. Per Section 29-102 an evaluation should be conducted on the basis of
existing downstream development and any analysis of stormwater runoff with
and without the proposed development. If the proposed development will
cause or increase downstream flooding conditions, provision to minimize
such flooding should be included in the design of the storm management
improvements. Such provisions may include downstream improvements
and/or detention of stormwater runoff and its regulated discharge to the
downstream stream storm drainage system.
9. Stormwater detention ordinance applies to this property. Maintenance of the
detention pond and all private drainage improvements is the responsibility of
the developer and/or local property owner's association and detailed in the
bill of assurance.
10. If disturbed area is one (1) or more acres, obtain a NPDES stormwater permit
from the Arkansas Department of Environmental Quality prior to the start of
construction.
11. Street Improvement plans shall include signage and striping. Public Works
must approve completed plans prior to construction.
12. Streetlights are required by Section 31-403 of the Little Rock code. Provide
plans for approval to Traffic Engineering. Streetlights must be installed
prior to platting/certificate of occupancy. Contact Greg Simmons,
Traffic Engineering 501.379.1813 or gsimmonsa littlerock,gov for more
information.
13. Street names and street naming conventions must be approved by Public
Works. Contact Glenn Haley, 501.371.4537 or c
1haley(Mittlerock.gov.
14. A turnaround must be provided at the end of the proposed street until a
through connection is made.
15. Provide a letter prepared by a registered engineer certifying the intersection
sight distance at the intersection(s) comply with 2004 AASHTO Green Book
standards.
3
FILE NO.: Z-9257 (Cont.
16. Damage to public and private property due to hauling operations or operation
of construction related equipment from a nearby construction site shall be
repaired by the responsible party prior to issuance of a certificate of
occupancy.
17. Access to detention ponds must be provided to the public right-of-way and/or
access easement for future maintenance by the developer and/or local
property owners' association.
18. Driveway locations and widths do not meet the traffic access and circulation
requirements of Sections 30-43 and 31-210. The width of driveway must
not exceed 36 feet. Driveway spacing on commercial streets is 250 feet from
intersecting street right-of-ways and other driveways.
19. Show the location of Huff Lane on the proposed plan located the east side of
Vimy Ridge Road.
20. All driveways shall be concrete aprons per City Ordinance.
21. Provide a letter prepared by a registered engineer certifying the intersection
sight distance at the intersection(s) comply with 2004 AASHTO Green Book
standards.
22. Provide a Sketch Grading and Drainage Plan per Section 29-186 (e).
E. Utilities/Fire Department/Parks/County Planning:
Little Rock Water Reclamation Authorit : Sewer main extension required with
easements if new sewer service is required for this project. Capacity analysis
required. EAD Analysis required. Contact Little Rock Water Reclamation Authority
for additional information.
Entergy: Entergy does not object to this proposal. There do not appear to be any
conflicts with existing electrical utilities on the property based on the information
provided. However, there is an existing three phase, overhead power line running
along the west side of Vimy Ridge Road which may be in conflict with proposed
road widening related to the project. Contact Entergy in advance to discuss
electrical service requirements, or adjustments to existing facilities (if any) as this
project proceeds.
Centerpoint Energy: No comment received.
AT & T: No comment received.
Central Arkansas Water:
1. All Central Arkansas Water requirements in effect at the time of request for
water service must be met.
2. The Little Rock Fire Department needs to evaluate this site to determine
whether additional public and/or private fire hydrant(s) will be required. If
12
FILE NO.: Z-9257
additional fire hydrant(s) are required, they will be installed at the Developer's
expense.
3. Please submit plans for water facilities and/or fire protection system to Central
Arkansas Water for review. Plan revisions may be required after additional
review. Contact Central Arkansas Water regarding procedures for installation
of water facilities and/or fire service. Approval of plans by the Arkansas
Department of Health Engineering Division and the Little Rock Fire Department
is required.
4. The facilities on -site will be private. When meters are planned off private lines,
private facilities shall be installed to Central Arkansas Water's materials and
construction specifications and installation will be inspected by an engineer,
licensed to practice in the State of Arkansas. Execution of a Customer Owned
Line Agreement is required.
5. Due to the nature of this facility, installation of an approved reduced pressure
zone backflow preventer assembly (RPZA) is required on the domestic water
service. This assembly must be installed prior to the first point of use. Central
Arkansas Water requires that upon installation of the RPZA, successful tests
of the assembly must be completed by a Certified Assembly Tester licensed by
the State of Arkansas and approved by Central Arkansas Water. The test
results must be sent to Central Arkansas Water's Cross Connection Section
within ten days of installation and annually thereafter. Contact the Cross
Connection Section at 501.377.1226 if you would like to discuss backflow
prevention requirements for this project.
6. The facilities on -site will be private. When meters are planned off private lines,
private facilities shall be installed to Central Arkansas Water's materials and
construction specifications and installation will be inspected by an engineer,
licensed to practice in the State of Arkansas. Execution of a Customer Owned
Line Agreement is required.
7. Fire sprinkler systems which do not contain additives such as antifreeze shall
be isolated with a double detector check valve assembly. If additives are used,
a reduced pressure zone back flow preventer shall be required.
Fire Department:
Maintain Access:
2. Fire Hydrants. Maintain fire apparatus access roads at fire hydrant locations
as per Appendix D of the 2012 Arkansas Fire Prevention Code Vol. 1 Section
D103.1 Access road width with a hydrant. Where a fire hydrant is located on
a fire apparatus access road, the minimum road width shall be 26 feet,
exclusive of shoulders.
3. Grade. Maintain fire apparatus access roads as per Appendix D of the
2012 Arkansas Fire Prevention Code Vol. 1 Section D103.2 Grade. Fire
apparatus access roads shall not exceed 10 percent in grade except as
approved by the fire chief.
5
FILE NO.: Z-9257 (Cont.
4. Loading_ Maintain fire apparatus access road design as per Appendix
D of the 2012 Arkansas Fire Prevention Code Vol. 1 Section D102.1 Access
and loading. Facilities, buildings or portions of buildings hereafter constructed
shall be accessible to fire department apparatus by way of an approved fire
apparatus access road with an asphalt, concrete or other approved driving
surface capable of supporting the imposed load of fire apparatus weighing at
least 75,000 pounds.
5. Commercial and Industrial Developments — 2 means of access. - Maintain
fire apparatus access roads as per Appendix D of the 2012 Arkansas Fire
Prevention Code Vol. 1
a. Section D104.1 Buildings exceeding three stories or 30 feet in height.
Building or facilities exceeding 30 feet or three stories in height shall
have at least two means of fire apparatus access for each structure.
b. Section D104.2 Building exceeding 62,000 square feet in area.
Buildings or facilities having a gross building area of more than
62,000 square feet shall be provide with two separate and approved
fire apparatus access roads.
C. Exception: Projects having a gross building area of up to 124,000
square feet that have a single approved fire apparatus access road
when all building are equipped throughout with approved automatic
sprinkler systems.
d. D104.3 Remoteness. Where two fire apparatus access roads are
required, they shall be placed a distance apart equal to not less than
one half of the length of the maximum overall diagonal dimension of
the lot or area to be served, measured in a straight line between
accesses.
6. 30' Tall Buildings - Maintain aerial fire apparatus access roads as per
Appendix D of the 2012 Arkansas Fire Prevention Code Vol. 1 Section D105.1
— D 105.4
a. D105.1 Where Required. Where the vertical distance between the
grade plane and the highest roof surface exceed 30', approved aerial
fire apparatus access roads shall be provided. For the purposes of
this section the highest roof surfaces shall be determined by
measurement to the eave of a pitched roof, the intersection of a roof
to the exterior wall, or the top of the parapet walls, whichever is
greater.
b. D105.2 Width. Aerial fire apparatus access roads shall have a
minimum unobstructed with of 26', exclusive of shoulders, in the
immediate vicinity of the building or portion thereof.
c. D105.3 Proximity to building. At least one of the required access
routes meeting this condition shall be located within a minimum of 15
feet and a maximum of 30 feet from the building, and shall be
positioned parallel to one entire side of the building. The side of the
0
FILE NO.: Z-9257 (Cont.
building on which the aerial fire apparatus access road is positioned
shall be approved by the fire code official.
d. D105.4 Obstructions. Overhead utility and power lines shall not be
located over the aerial fire apparatus access road or between the
aerial fire apparatus road and the building. Other obstructions shall
be permitted to be places with the approval of the fire code official.
7. Dead Ends. Maintain fire apparatus access roads at dead end locations as
per Appendix D of the 2012 Arkansas Fire Prevention Code Vol. 1 Section
D103.4 Dead Ends. Dead-end fire apparatus access roads in excess of
150 feet shall be provided with width and turnaround provisions in accordance
with Table D103.4. Requirements for Dead-end fire apparatus access roads.
8. Gates. Maintain fire apparatus access road gates as per Appendix D of the
2012 Arkansas Fire Prevention Code Vol. 1 Section D103.5 Fire apparatus
access road gates. Gates securing the fire apparatus access roads shall
comply with all of the following criteria:
1. Minimum gate width shall be 20 feet.
2. Gates shall be of swinging or sliding type.
3. Construction of gates shall be of material that allow manual operation
by one person.
4. Gate components shall be maintained in an operable condition at all
times and replaces or repaired when defective.
5. Electric gates shall be equipped with a means of opening the gate by
fire department personnel for emergency access. Emergency opening
devices shall be approved by the fire code official.
6. Manual opening gates shall not be locked with a padlock or chain and
padlock unless they are capable of being opened by means of forcible
entry tools or when a key box containing the keys to the lock is installed
at the gate location.
7. Locking device specifications shall be submitted for approval by the
fire code official
8. Electric gate operators, where provided, shall be listed in accordance
with U L 325.
9. Gates, intended for automatic operation shall be designed,
constructed and installed to comply with requirements of ASTM F
2200.
9. Multi -family Residential Developments - As per Appendix D, Section D106.1
of the 2012 Arkansas Fire Prevention Code Vol. 1. Projects having more than
100 dwelling units. Multiple -family residential projects having more than
100 dwelling units shall be equipped throughout with two separate and
approved fire apparatus access roads.
a. Exception: Projects having up to 200 dwelling units may have a single
approved fire apparatus access road when all building, including
7
FILE NO.: Z-9257 (Cont.
nonresidential occupancies are equipped throughout with approved
automatic sprinkler systems installed in accordance with Section
903.3.1.1 or 903.3.1.2.
b. As per Appendix D, Section D106.2 of the 2012 Arkansas Fire prevention
Code Vol. 1. Projects having more than 200 dwelling units. Multiple -family
residential projects having more than 200 dwelling units shall be provided
with two separate and approved fire apparatus access roads regardless
of whether they are equipped with an approved automatic sprinkler
system.
10. Fire Hydrants. Locate Fire Hydrants as per Appendix C of the
2012 Arkansas Fire Prevention Code. Section C101 — C105, in conjunction
with Central Arkansas Water (Jason Lowder 501.377.1245) and the
Little Rock Fire Marshal's Office (Capt. Tony Rhodes 501.918.3757 or
Capt. John Hogue 501.918.3754). Number and Distribution of Fire Hydrants
as per Table C105.1.
Parks and Recreation: No comment received.
County Planning: No comment.
F. Building Codes/Landscape-,
Building Code: Project is subject to full commercial plan review and approval prior
to issuance of a building permit. For information on submittal requirements and the
review process, contact a commercial plans examiner:
Curtis Richey at 501.371.4724; crichey(&Iittlerock.gov or
Mark Alderfer at 501.371.4875; malderfer aC__littlerock.go�
Landscape-
1 . Site plan must comply with the City's landscape and buffer ordinance
requirements.
2. Street buffers will be required at six (6) percent of the average depth of the lot.
The minimum dimension shall be one-half (Y2) the full width requirement but in
no case less than nine (9) feet. The maximum dimension required shall be fifty
(50) feet. The average depth of Lot 5 is approximately 450 feet a minimum
twenty-seven (27) foot street buffer will be required adjacent to the Pleasant
Hill Road right-of-way.
3. A land use buffer six (6) percent of the average width/depth of the lot will be
required when an adjacent property has a dissimilar use of a more restrictive
nature. The properties to the north and west are zoned R-2, Single-family. The
maximum dimension required shall be fifty (50) feet. As a component of all land
use buffer requirements, opaque screening, whether a fence or other device, a
minimum of six (6) feet in height shall be required upon the property line side
of the buffer. A minimum of seventy (70) percent of the land use buffer shall be
n
FILE NO.: Z-9257 (Cont.
undisturbed. Easements cannot count toward fulfilling this requirement.
Existing and planted vegetation may be used to achieve the required screening.
In addition to the required screening, buffers are to be landscaped at the rate
of one (1) tree and three (3) shrubs for every thirty (30) linear feet. The
approximate average depth of the Lots 1, 3, 4 is approximately 360 feet.
A minimum twenty-two (22) foot buffer adjacent to the north property line will
be required. The approximate width of Lot 5 is 680 feet. A minimum forty-one
(41) foot buffer adjacent to the west property line will be required.
4. Screening requirements will need to be met for the vehicular use areas
adjacent to street right-of-ways. Provide screening shrubs with an average
linear spacing of not less at three (3) feet within the required landscape area.
Provide trees with an average linear spacing of not less than thirty (30) feet.
5. A perimeter planting strip is required along any side of a vehicular use area that
abuts adjoining property or the right-of-way of any street. This strip shall be at
least nine (9) feet wide. One (1) tree and three (3) shrubs or vines shall be
planted for every thirty (30) linear feet of perimeter planting strip.
6. An automatic irrigation system to water landscaped areas shall be required for
developments of one (1) acre or larger.
7. The development of two (2) acres or more requires the landscape plan to be
stamped with the seal of a Registered Landscape Architect.
8. The City Beautiful Commission recommends preserving as many existing trees
as feasible on this site. Credit toward fulfilling Landscape Ordinance
requirements can be given when preserving trees of six (6) inch caliper or
larger.
G. Transportation/Planni
Rock Region Metro: METRO does not currently serve this location but it is in our
long range plans. Our only concern for the plan as presented if the need to provide
sidewalks throughout the complex for access to future trail and transit routes. The
site is located near the Southwest trail which will provide a short bicycle commute
to the existing transit route. Sidewalks are included in the promotional renderings
but no the plans.
Planning Division: This request is located in Otter Creek Planning District. The
Land Use Plan shows Residential Medium (RM) and Residential Low Density (RL)
for this property. The Residential Medium Density (RM) category accommodates
a broad range of housing types including single family attached, single family
detached, duplex, town homes, multi -family and patio or garden homes. Any
combination of these and possibly other housing types may fall in this category
provided that the density is between six (6) and twelve (12) dwelling units per acre.
The Residential Low Density category provides for single family homes at densities
not to exceed six (6) units per acre. Such residential development is typically
characterized by conventional single family homes, but may include patio or
garden homes and cluster homes, provided that the density remain less than
9
FILE NO.: Z-9257 (Cont.
six (6) units per acre. The applicant has applied for a rezoning from R-2 (Single
Family District) to PCD (Planned Commercial Development) to allow C-3 uses, a
mini -warehouse and assisted living facility.
Master Street Plan: South of the property is Pleasant Hill Road and it is shown as
a Collector Street on the Master Street Plan. Plan. East of the property is Vimy
Ridge Road and it is shown as a Minor Arterial Street on the Master Street Plan.
The primary function of a Collector Road is to provide a connection from Local
Streets to Arterials. A Minor Arterial provides connections to and through an urban
area and their primary function is to provide short distance travel within the
urbanized area. Entrances and exits should be limited to minimize negative effects
of traffic and pedestrians on Vimy Ridge Road since it is a Minor Arterial. These
streets may require dedication of right-of-way and may require street
improvements for entrances and exits to the site.
Bicycle Plan: There are no bike routes shown in the immediate vicinity.
H. SUBDIVISION COMMITTEE COMMENT: (September 20, 2017)
The applicant was present. Staff presented an overview of the item stating there
were a number of outstanding technical issues in need of addressing. Staff
requested the proposed signage plan, the days and hours of operation, the hours
of dumpster service and the location, height and materials of any proposed
fencing.
Public Works comments were addressed. Staff stated Vimy Ridge Road was
classified on the Master Street Plan as a minor arterial which would require right
of way dedication to 45-feet from centerline. Staff stated the proposed commercial
street should be constructed within a 60-foot right of way and 36-feet width from
back of curb to back of curb with sidewalks on both sides and access ramps at
intersections. Staff stated the proposed median lengths may be altered from the
approved plans to provide sufficient left turn stack depending on estimated traffic
generations from the adjacent development.
Landscaping comments were addressed. Staff stated with the site development it
would be necessary to comply with the landscape and buffer ordinances. Staff
stated screening was required adjacent to less restrictive uses such as the
residential to the north and the west. Staff stated developments of two (2) or more
acres would require a landscape plan stamped with the seal of a landscape
architect.
Staff noted the comments from the various other departments and agencies. Staff
suggested the applicant contact the departments or agencies directly with any
questions or concerns. There were no more issues for discussion. The Committee
then forwarded the item to the full Commission for final action.
10
FILE NO.: Z-9257 (Cont.)
ANALYSIS:
The applicant submitted a revised site plan and cover letter to staff addressing
most of the technical issues associated with the request. The applicant has
provided the proposed signage plan, the days and hours of operation, the location
of any proposed dumpsters, the hours of dumpster service and the height and
materials of the proposed fencing
The request is a rezoning of the site from R-2, Single-family to PCD, Planned
Commercial Development, to allow the development of the site as a mixed use
development. The applicant is proposing a five (5) lot subdivision. Lots 1 - 3 will
be developed utilizing the C-3, General Commercial District uses as allowable
uses. Lot 4 is indicated as elderly housing and Lot 5 with mini -warehouse.
Lot 1 is proposed containing 2.51-acres. Lot 1 is proposed for development with
a 16,000 square foot retail building utilizing C-3, General Commercial District uses.
Lot 2 is proposed containing 6.09-acres developed with a 43,600 square foot
building. The lot is proposed utilizing C-3, General Commercial District uses
and/or a grocery store. Lot 3 is proposed containing 2.73-acres. The lot is
proposed with a 30,000 square foot four (4) bay retail strip center utilizing C-3,
General Commercial District uses. Lot 4 is proposed containing 4.31-acres
developed with a 46,000 square foot assistance living facility. Lot 5 is proposed
containing 7.56-acres. The development plan for Lot 5 consists of 35 buildings,
100-feet by 20-feet, of mini -warehouse.
The development is proposed with 1,400 linear feet of new public street. The street
is proposed with a back of curb to back of curb width of 51-feet. The street
is proposed as a divided median street. The street is proposed with a
two (2) foot curb, a five (5) foot bike lane, an eleven (11) foot driving surface,
a 15-foot median, a eleven (11) foot driving lane, a five (5) foot bike lane, a
two (2) foot curb.
The applicant indicates each of the lots will have individual signs. The signs are
proposed as monument signs with a maximum height of six (6) feet and a
maximum sign area of 36 square feet. Building signage is proposed consistent
with signage allowed in commercial zones or a maximum of ten (10) percent of the
front fagade area. Corner lots will be allowed signage on each fagade with public
street frontage.
The hours of operation for the retail portion of the development are from 6 am to
10 pm seven (7) days per week. The grocery building hours will vary from 6 am to
10 pm, depending on the building tenant. The retail/restaurant portion of the
development is proposed from 8 am to 10 pm also depending on the tenant. The
mini -warehouse portion of the development will have 24-hour key pad access.
The office hours are typical office hours, 8 am to 6 pm Monday through Friday.
The applicant indicates an on -site manager residences is included in the request.
11
FILE NO.: Z-9257 (Cont.
The plan notes each lot will have a dumpster. The dumpster hours of service are
limited to 7 am to 6 pm Monday through Friday. Each of the dumpsters will be
screened to meet the typical ordinance requirements.
The plan indicates all site lighting will be low level and directional, directed
downward and into the site. The height of the parking lot poles will be limited to
lessen the potential impact to adjacent properties. The maximum building height
proposed is 35-feet.
The applicant indicates the grocery building will begin construction in the summer
of 2018. The mini -storage is also proposed for construction in the summer of 2018.
The retail/restaurant proposed on Lot 1 is proposed for construction in the fall of
2018. The retail building located on Lot 3 is proposed for construction in the
summer of 2019 and the assisted living is proposed for construction in the summer
of 2019. The mini -warehouse portion of the development is proposed in a single
phase.
The applicant indicates screening will be provided along the northern and southern
perimeter via dense evergreen plantings and/or solid board fences or walls. The
applicant states a 50-foot undisturbed buffer will be provided along Pleasant Hill
Road to provide the proper screening for the mini -warehouse development. The
mini -warehouse portion of the development is proposed with chain link fencing a
maximum of eight (8) feet in height.
Staff is supportive of the applicant's request. The applicant is seeking approval of
a rezoning from R-2, Single-family Residential to PCD, Planned Commercial
Development to allow the development of a commercial node at the intersection of
the future collector street and Vimy Ridge Road. The commercial is proposed to
serve the newly developing townhouse community to the north as well as residents
in the area. To staff's knowledge there are no remaining outstanding technical
issues associated with the request. Staff feels the development of the site as
proposed by the applicant is appropriate.
J. STAFF RECOMMENDATION -
Staff recommends approval of the request subject to compliance with the
comments and conditions as outlined in paragraphs D, E and F of the agenda staff
report.
PLANNING COMMISSION ACTION: (OCTOBER 12, 2017)
The applicant was present. There were no registered objectors present. Staff presented
the item with a recommendation of approval of the request subject to compliance with the
comments and conditions as outlined in paragraphs D, E and F of the agenda staff report.
There was no further discussion. The item was placed on the consent agenda and
approved as recommended by staff by a vote of 9 ayes, 0 noes and 2 absent.
12
ITEM NO.: 10,
NAME: Big Rock Plaza Long -form PCD
Z-9257
LOCATION: located on the Northwest corner of Pleasant Hill Road and Vimy Ridge Road
Plannina Staff Comments:
Provide notification of all property owners located within 200-feet of the site including the
certified abstract list, notice form with affidavit executed and proof of mailing. The notice
must be mailed no later than September 27, 2017. The Office of Planning and Development
must receive the proof of notice no later than October 6, 2017.
Will comply, notifications have been sent. Affidavit to be provided to planning by Brad
Walker.
2. What commercial uses are being proposed for the use of the buildings? C-1, Neighborhood
Commercial, C-2, Shopping Center District, C-3, General Commercial.
• Mixed use commercial is being proposed as there are plans for a grocery building, a 4
building strip mall, and a retail/restaurant building.
3. Provide details of the proposed signage plan including location total height and total sign
area for ground signage. Provide details of the proposed building signage including the
location and total sign area proposed.
A signage plan will be provided at the time construction plans are submitted for approval to
the City of Little Rock. Ground signs will conform to City of Little Rock code. It is our intention
that ground monument signs be no larger than 6 x 6 with an area of 36 sf. Building signage
will also meet City of Little Rock Code, maintaining the allowable percentage of the front
fagade of each building.
4. Provide the days and hours of operation for the businesses.
The hours of operation of the 4-building strip mall would be between the hours of 7am and
9pm (depending on building tenants). The grocery building hours would vary from 6am to 8-
10pm (depending on building tenant). The retail / restaurant building will be from 8-10am to
7-9pm (depending on building tenants)
5. Will there be a dumpster located on the site? If so provide the location of the proposed
dumpster and a note indicting the screening. Staff recommends the hours of dumpster
service be limited to 7 am to 6 pm Monday through Friday.
Dumpsters shown on Preliminary Plat. Dumpster service note added to general notes stating
dumpster service will be limited to 7am to 6pm Monday through Friday.
6. Provide a site lighting plan. All site lighting must be low-level and directional, aimed
downward and into the site.
Site lighting plan to be provided at the time construction plans are submitted for approval to
the City of Little Rock. Site lighting will conform to City of Little Rock code. Site Lighting will
conform to low-level and directional, aimed downward and into the site.
ITEM NO.: 10. Z-9257
7. Provide a development schedule indicating the approximately date when construction of
the planned unit development or stages of the planned unit development can be expected
to begin and be completed.
Grocery Building — Estimated Summer 2018
Mini -Storage — Estimated Summer 2018
Retail/Restaurant — Estimated Fall 2018
w 4-Building Strip Mall — Estimated Summer 2019
a Assisted Living — Estimated Summer 2019
8. Provide the maximum building height in the general notes section of the site plan.
i. Will comply, maximum building height to not exceed 30'
9. Provide details of all and any proposed fencing. Include the location, the construction
materials, total height of the proposed fences.
+ Chain link fencing will be proposed around the mini -storage site and will be gated at the
single entryway. A minimum 50' wooded/landscaped area will remain as a buffer to mask
the mini -storage site from the proposed roadway.
10. Provide the proposed phasing plan for the mini -warehouse development.
• The mini -storage facility will be built in a single phase.
11. Provide details of the proposed development including amenities to be offered to the
residents, any medical/nursing staff to be provided, transportation.
12. Provide on the site plan any outdoor patios, areas for outdoor activities and/or areas for
outdoor gardens.
• Outdoor patios and areas for outdoor activities will be provided to the north of the
assisted living facility for the residents. Areas shown on the plat.
13. Will the elderly housing development be gated?
■ The assisted living facility will not be gated, but will be fenced in the rear (north).
14.
VarianceNVaivers: None requested.
Engineering Comments:
Public Works Conditions:
1. Vimy Ridge Road is classified on the Master Street Plan as a minor arterial. A dedication
of right-of-way 45 feet from centerline will be required.
+ Will Comply
2. Pleasant Hill Road is classified on the Master Street Plan as a collector street. A dedication
of right-of-way 30 feet from centerline will be required. (Unless the collector street is moved
to the north through this proposed development.)
• The thought is to move the collector street to the north through this development and
allow Pleasant Hill Road to remain private.
3. The proposed commercial street should be constructed within a 60 foot wide right-of-way
and 36 feet width from back of curb to back of curb with sidewalks on both sides and access
ITEM NO.: 10.
Z-9257
ramps at intersections. The proposed median lengths may be altered from approved plans
to provide sufficient left turn lane stack depending on estimated traffic generation from the
adjacent development.
• As discussed with Vince Floriani, a 60 foot ROW will be used, but a 51 street back of
curb to back of curb will be utilized to provide a 2 foot curb, a 5 foot bike lane, an 11 foot
driving surface, a 15 foot median, an 11 foot driving lane, a 5 foot bike lane, a 2 foot curb
cross section of the proposed roadway.
4. A 20 foot radial dedication of right-of-way is required at the intersection of Vimy Ridge Road
and Pleasant Hill Road.
Will comply
5. With site development, provide the design of street conforming to the Master Street Plan.
Construct one-half street improvement to Vimy Ridge Road including 5-foot sidewalks with
the planned development. The new back of curb should be located 29.5 feet from
centerline. The proposed sidewalk may be required to be placed of the north side of the
Centerpoint gas pipeline station. A left turn lane should be provided on north bound Vimy
Ridge Road.
J Will comply
6. With site development, provide the design of street conforming to the Master Street Plan.
Construct one-half street improvement to Pleasant Hill Road including 5-foot sidewalks with
the planned development. The new back of curb should located 13 feet from centerline of
the existing street. The new sidewalk maybe required to be placed on the north and west
sides of the Centerpoint gas pipeline
■ We are currently doing title work and tracing the legal descriptions that include Pledsarit
Hill Road. The current subdivision plat of Quail Run subdivision shows no ROW of
Pleasant Hill road. The survey performed by Mike Johnston shows Pleasant Hill Road
mostly contained in our property description. We would like to leave this road private as
there is no access to our development from Pleasant Hill Road.
7. A grading permit in accordance with Section 29-186 (c) and (d) will be required prior to any
land clearing or grading activities at the site. Other than residential subdivisions, site
grading and drainage plans must be submitted and approved prior to the start of
construction. Is a variance being requested to advance grade the lots with the construction
of the street?
■ Will comply. It is the intention to grade the lots as tenants have been found, not with the
construction of the road. This will allow the possibility of more existing trees to remain
should the layout of the buildings and how they sit on the lot change.
8. Per Section 29-102 an evaluation should be conducted on the basis of existing downstream
development and any analysis of stormwater runoff with and without the proposed
development. If the proposed development will cause or increase downstream flooding
conditions, provision to minimize such flooding should be included in the design of the storm
management improvements. Such provisions may include downstream improvements
and/or detention of stormwater runoff and its regulated discharge to the downstream stream
storm drainage system.
■ Will comply. Stormwater runoff analysis will performed at the time of construction plan
submittal to the City of Little Rock.
ITEM NO.: 10.
Z-9257
9. Stormwater detention ordinance applies to this property. Maintenance of the detention
pond and all private drainage improvements is the responsibility of the developer and/or
local property owner's association and detailed in the bill of assurance.
Will comply. Note provided on preliminary plat.
10. If disturbed area is one (1) or more acres, obtain a NPDES stormwater permit from the
Arkansas Department of Environmental Quality prior to the start of construction.
• Will comply. An NPDES permit for this site will be necessary and filed at the time of
submittal of roadway construction plans.
11. Street Improvement plans shall include signage and striping. Public Works must approve
completed plans prior to construction.
mj Will comply
12. Streetlights are required by Section 31-403 of the Little Rock code. Provide plans for
approval to Traffic Engineering. Streetlights must be installed prior to platting/certificate of
occupancy. Contact Greg Simmons, Traffic Engineering 501.379.1813 or
gsimmons@littlerock.gov for more information.
Will comply
13. Street names and street naming conventions must be approved by Public Works. Contact
Glenn Haley, 501.371.4537 or ghaleyCrr7�littierock.gov.
Will comply
14.A turnaround must be provided at the end of the proposed street until a through connection
is made.
41 Will comply. Circular turn around shown on the preliminary plat at the current proposed
street end.
15. Provide a letter prepared by a registered engineer certifying the intersection sight distance
at the intersection(s) comply with 2004 AASHTO Green Book standards.
Will comply. Letter will be submitted at the time of construction plan submittal to the City
of Little Rock.
16. Damage to public and private property due to hauling operations or operation of
construction related equipment from a nearby construction site shall be repaired by the
responsible party prior to issuance of a certificate of occupancy.
Will comply
17. Access to detention ponds must be provided to the public right-of-way and/or access
easement for future maintenance by the developer and/or local property owners'
association.
9 Will comply
18. Driveway locations and widths do not meet the traffic access and circulation requirements
of Sections 30-43 and 31-210. The width of driveway must not exceed 36 feet. Driveway
spacing on commercial streets is 250 feet from intersecting street right-of-ways and other
driveways.
Will comply. Driveways shown do not exceed 36 feet and are spaced greater than 250
feet from other driveways.
Il
ITEM NO.: 10, Z-9257
19. Show the location of Huff Lane on the proposed plan located the east side of Vimy Ridge
Road.
Will comply
20.All driveways shall be concrete aprons per City Ordinance.
Will comply
21. Provide a letter prepared by a registered engineer certifying the intersection sight distance
at the intersection(s) comply with 2004 AASHTO Green Book standards.
Will Comply
22. Provide a Sketch Grading and Drainage Plan per Section 29-186 (e).
Will Comply. Sketch Grading and Drainage Plan Provided.
Utilities/Fire Department/Parks/CountyDepartment/Parks/County Plannin
Little Rock Water Reclamation Authority: sewer main extension required with easements if
new sewer service is required for this project. Capacity analysis required. EAD Analysis
required. Contact Little Rock Water Reclamation Authority for additional information.
Entergy: Entergy does not object to this proposal. There do not appear to be any conflicts with
existing electrical utilities on the property based on the information provided. However, there
is an existing three phase, overhead power line running along the west side of Vimy Ridge
Road which may be in conflict with proposed road widening related to the project. Contact
Entergy in advance to discuss electrical service requirements, or adjustments to existing
facilities (if any) as this project proceeds.
Centerpoint Energy: No comment received.
AT & T: No comment received.
Central Arkansas Water:
1. All Central Arkansas Water requirements in effect at the time of request for water service
must be met.
2. The Little Rock Fire Department needs to evaluate this site to determine whether additional
public and/or private fire hydrant(s) will be required. If additional fire hydrant(s) are required,
they will be installed at the Developer's expense.
3. Please submit plans for water facilities and/or fire protection system to Central Arkansas
Water for review. Plan revisions may be required after additional review. Contact Central
Arkansas Water regarding procedures for installation of water facilities and/or fire service.
Approval of plans by the Arkansas Department of Health Engineering Division and the Little
Rock Fire Department is required.
4. The facilities on -site will be private. When meters are planned off private lines, private
facilities shall be installed to Central Arkansas Water's materials and construction
specifications and installation will be inspected by an engineer, licensed to practice in the
State of Arkansas. Execution of a Customer Owned Line Agreement is required.
ITEM NO.: 10, Z-9257
5. Due to the nature of this facility, installation of an approved reduced pressure zone backflow
preventer assembly (RPZA) is required on the domestic water service. This assembly must
be installed prior to the first point of use. Central Arkansas Water requires that upon
installation of the RPZA, successful tests of the assembly must be completed by a Certified
Assembly Tester licensed by the State of Arkansas and approved by Central Arkansas
Water. The test results must be sent to Central Arkansas Water's Cross Connection
Section within ten days of installation and annually thereafter. Contact the Cross
Connection Section at 501.377.1226 if you would like to discuss backflow prevention
requirements for this project.
6. The facilities on -site will be private. When meters are planned off private lines, private
facilities shall be installed to Central Arkansas Water's materials and construction
specifications and installation will be inspected by an engineer, licensed to practice in the
State of Arkansas. Execution of a Customer Owned Line Agreement is required.
7. Fire sprinkler systems which do not contain additives such as antifreeze shall be isolated
with a double detector check valve assembly. If additives are used, a reduced pressure
zone back flow preventer shall be required.
Fire Department:
1. Maintain Access:
2. Fire Hydrants. Maintain fire apparatus access roads at fire hydrant locations as per
Appendix D of the 2012 Arkansas Fire Prevention Code Vol. 1 Section D103.1 Access road
width with a hydrant. Where a fire hydrant is located on a fire apparatus access road, the
minimum road width shall be 26 feet, exclusive of shoulders.
3. Grade. Maintain fire apparatus access roads as per Appendix D of the 2012 Arkansas
Fire Prevention Code Vol. 1 Section D103.2 Grade. Fire apparatus access roads shall not
exceed 10 percent in grade except as approved by the fire chief.
4. Loading. Maintain fire apparatus access road design as per Appendix D of the 2012
Arkansas Fire Prevention Code Vol. 1 Section D102.1 Access and loading. Facilities,
buildings or portions of buildings hereafter constructed shall be accessible to fire
department apparatus by way of an approved fire apparatus access road with an asphalt,
concrete or other approved driving surface capable of supporting the imposed load of fire
apparatus weighing at least 75,000 pounds.
5. Commercial and Industrial Developments — 2 means of access. - Maintain fire apparatus
access roads as per Appendix D of the 2012 Arkansas Fire Prevention Code Vol. 1
a. Section D104.1 Buildings exceeding three stories or 30 feet in height. Building
or facilities exceeding 30 feet or three stories in height shall have at least two
means of fire apparatus access for each structure.
b. Section D104.2 Building exceeding 62,000 square feet in area. Buildings or
facilities having a gross building area of more than 62,000 square feet shall be
provide with two separate and approved fire apparatus access roads.
ITEM NO.: 10. Z-9257
C. Exception: Projects having a gross building area of up to 124,000 square feet
that have a single approved fire apparatus access road when all building are
equipped throughout with approved automatic sprinkler systems.
d. D104.3 Remoteness. Where two fire apparatus access roads are required, they
shall be placed a distance apart equal to not less than one half of the length of
the maximum overall diagonal dimension of the lot or area to be served,
measured in a straight line between accesses.
6. 30' Tall Buildings - Maintain aerial fire apparatus access roads as per Appendix D of the
2012 Arkansas Fire Prevention Code Vol. 1 Section D105.1 — D105.4
a. D105.1 Where Required. Where the vertical distance between the grade plane
and the highest roof surface exceed 30', approved aerial fire apparatus access
roads shall be provided. For the purposes of this section the highest roof surfaces
shall be determined by measurement to the eave of a pitched roof, the
intersection of a roof to the exterior wall, or the top of the parapet walls, whichever
is greater.
b. D105.2 Width. Aerial fire apparatus access roads shall have a minimum
unobstructed with of 26', exclusive of shoulders, in the immediate vicinity of the
building or portion thereof.
c. D105.3 Proximity to building. At least one of the required access routes meeting
this condition shall be located within a minimum of 15 feet and a maximum of 30
feet from the building, and shall be positioned parallel to one entire side of the
building. The side of the building on which the aerial fire apparatus access road
is positioned shall be approved by the fire code official.
d. D105.4 Obstructions. Overhead utility and power lines shall not be located over
the aerial fire apparatus access road or between the aerial fire apparatus road
and the building. Other obstructions shall be permitted to be places with the
approval of the fire code official.
7. Dead Ends. Maintain fire apparatus access roads at dead end locations as per Appendix
D of the 2012 Arkansas Fire Prevention Code Vol. 1 Section D103.4 Dead Ends. Dead-end
fire apparatus access roads in excess of 150 feet shall be provided with width and
turnaround provisions in accordance with Table D103.4. Requirements for Dead-end fire
apparatus access roads.
8. Gates. Maintain fire apparatus access road gates as per Appendix D of the 2012
Arkansas Fire Prevention Code Vol. 1 Section D103.5 Fire apparatus access road gates.
Gates securing the fire apparatus access roads shall comply with all of the following criteria:
1. Minimum gate width shall be 20 feet.
2. Gates shall be of swinging or sliding type.
3. Construction of gates shall be of material that allow manual operation by one person.
4. Gate components shall be maintained in an operable condition at all times and
replaces or repaired when defective.
ITEM NO.: 10,
Z-9257
5. Electric gates shall be equipped with a means of opening the gate by fire department
personnel for emergency access. Emergency opening devices shall be approved by
the fire code official.
6. Manual opening gates shall not be locked with a padlock or chain and padlock unless
they are capable of being opened by means of forcible entry tools or when a key box
containing the keys to the lock is installed at the gate location.
7. Locking device specifications shall be submitted for approval \by the fire code official
8. Electric gate operators, where provided, shall be listed in accordance with UL 325.
9. Gates, intended for automatic operation shall be designed, constructed and installed
to comply with requirements of ASTM F 2200.
9. Multi -family Residential Developments - As per Appendix D, Section D106.1 of the 2012
Arkansas Fire Prevention Code Vol. 1. Projects having more than 100 dwelling units.
Multiple -family residential projects having more than 100 dwelling units shall be equipped
throughout with two separate and approved fire apparatus access roads.
a. Exception: Projects having up to 200 dwelling units may have a single approved fire
apparatus access road when all building, including nonresidential occupancies are
equipped throughout with approved automatic sprinkler systems installed in accordance
with Section 903.3.1.1 or 903.3.1.2.
b. As per Appendix D, Section D106.2 of the 2012 Arkansas Fire prevention Code Vol. 1.
Projects having more than 200 dwelling units. Multiple -family residential projects having
more than 200 dwelling units shall be provided with two separate and approved fire
apparatus access roads regardless of whether they are equipped with an approved
automatic sprinkler system.
10. Fire Hydrants. Locate Fire Hydrants as per Appendix C of the 2012 Arkansas Fire
Prevention Code. Section C101 — C105, in conjunction with Central Arkansas Water (Jason
Lowder 501.377.1245) and the Little Rock Fire Marshal's Office (Capt. Tony Rhodes
501.918.3757 or Capt. John Hogue 501.918.3754). Number and Distribution of Fire
Hydrants as per Table C105.1.
Parks and Recreation: No comment received.
County_ Planning_ No comment.
Will comply to all Utilities/Fire Department/Parks/County Planning standard comments.
Building Codes/Landscape:
Building Code: Project is subject to full commercial plan review and approval prior to
issuance of a building permit. For information on submittal requirements and the review
process, contact a commercial plans examiner:
ITEM NO.: 10-
Z-9257
Landscape:
Curtis Richey at 501.371.4724; crichey(cD-littlerock.glo_y or
Mark Alderfer at 501.371.4875; malderfer aC__littlerock.gov
1. Site plan must comply with the City's landscape and buffer ordinance requirements.
2. Street buffers will be required at six (6) percent of the average depth of the lot. The minimum
dimension shall be one-half (Y2) the full width requirement but in no case less than nine (9)
feet. The maximum dimension required shall be fifty (50) feet. The average depth of Lot 5
is approximately 450 feet a minimum twenty-seven (27) foot street buffer will be required
adjacent to the Pleasant Hill Road right-of-way.
Will comply. A 30 foot street buffer has been shown.
3. A land use buffer six (6) percent of the average width/depth of the lot will be required when
an adjacent property has a dissimilar use of a more restrictive nature. The properties to the
north and west are zoned R-2, Single-family. The maximum dimension required shall be
fifty (50) feet. As a component of all land use buffer requirements, opaque screening,
whether a fence or other device, a minimum of six (6) feet in height shall be required upon
the property line side of the buffer. A minimum of seventy (70) percent of the land use buffer
shall be undisturbed. Easements cannot count toward fulfilling this requirement. Existing
and planted vegetation may be used to achieve the required screening. In addition to the
required screening, buffers are to be landscaped at the rate of one (1) tree and three (3)
shrubs for every thirty (30) linear feet. The approximate average depth of the Lots 1, 3, 4 is
approximately 360 feet. A minimum twenty-two (22) foot buffer adjacent to the north
property line will be required. The approximate width of Lot 5 is 680 feet. A minimum forty-
one (41) foot buffer adjacent to the west property line will be required.
A Will comply. A 60 foot buffer has been shown to the west.
4. Screening requirements will need to be met for the vehicular use areas adjacent to street
right-of-ways. Provide screening shrubs with an average linear spacing of not less at three
(3) feet within the required landscape area. Provide trees with an average linear spacing of
not less than thirty (30) feet.
0 Will comply
5. A perimeter planting strip is required along any side of a vehicular use area that abuts
adjoining property or the right-of-way of any street. This strip shall be at least nine (9) feet
wide. One (1) tree and three (3) shrubs or vines shall be planted for every thirty (30) linear
feet of perimeter planting strip.
Will comply
6. An automatic irrigation system to water landscaped areas shall be required for
developments of one (1) acre or larger.
Will comply
7. The development of two (2) acres or more requires the landscape plan to be stamped with
the seal of a Registered Landscape Architect.
- Will comply
ITEM NO.: 10. Z-9257
8. The City Beautiful Commission recommends preserving as many existing trees as feasible
on this site. Credit toward fulfilling Landscape Ordinance requirements can be given when
preserving trees of six (6) inch caliper or larger.
Will comply
Transportation/Planning:
Rock Region Metro: METRO does not currently serve this location but it is in our long range
plans. Our only concern for the plan as presented it the need to provide sidewalks throughout
the complex for access to future trail and transit routes. The site is located near the Southwest
trail which will provide a short bicycle commute to the existing transit route. Sidewalks are
included in the promotional renderings but no the plans.
Planning Division, This request is located in Otter Creek Planning District._District. The Land
Use Plan shows Residential Medium (RM) and Residential Low Density (RL) for this property.
The Residential Medium Density (RM) category accommodates a broad range of housing types
including single family attached, single family detached, duplex, town homes, multi -family and
patio or garden homes. Any combination of these and possibly other housing types may fall in
this category provided that the density is between (six) 6 and twelve (12) dwelling units per
acre. The Residential Low Density category provides for single family homes at densities not
to exceed 6 units per acre. Such residential development is typically characterized by
conventional single family homes, but may include patio or garden homes and cluster homes,
provided that the density remain less than 6 units per acre. The applicant has applied for a
rezoning from R2 (Single Family District) to PCD (Planned Commercial Development) to allow
C-3 uses, a Mini -Warehouse, and assisted living facility.
Master Street Plan: South of the property is Pleasant Hill Road and it is shown as a Collector
Street on the Master Street Plan. Plan. East of the property is Vimy Ridge Road and it is shown
as a Minor Arterial Street on the Master Street Plan. The primary function of a Collector Road
is to provide a connection from Local Streets to Arterials. A Minor Arterial provides connections
to and through an urban area and their primary function is to provide short distance travel within
the urbanized area. Entrances and exits should be limited to minimize negative effects of traffic
and pedestrians on Vimy Ridge Road since it is a Minor Arterial. These streets may require
dedication of right-of-way and may require street improvements for entrances and exits to the
site.
Bicycle Plan: There are no bike routes shown in the immediate vicinity.
Revised plat/plan: Submit four (4) copies of a revised preliminary plat/plan (to include the
additional information as noted above) to staff on Wednesday, September 27, 2017.