Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Z-9162 Map 2
/ AT&T/ 1/2° RB ED.O �— i S 89°3'0' E45.0' (Mews. &fie. , a� / ! 12G 78A / Ro'0' /i R15' 7 Z/Conc. 0 FL: 22 0 / Vicinity Map Not to Scale f r_ 5/8" R8 FD / W/ CAP ly S 89030'00" E 705.00' (Meal. & Rec.) RQ' PLANT LIST COMMON NAME/ ROOT SIZE REMARKS QTY BOTANICAL NAME BF':41APLE Aver mbrum'Rad Sun5�t- =5© -JA. PLANT AS SH'JWN 6 RF:i BUD Celcls canaNL^.csis BEP 2 SAL PLAN - AS SHOWN 4 FOSTENSHOLLY nlex attanuAta TOO W B&B 2' CAL PLANT AF; 61 OUIN 36 DWARF YAUPON HOLLY Illex uPI1VtOtia'Nene' 1 0$8 2' CAL PLAN` AS SHOWN i 301 40 Know what'sbelow. ' SCALE IN FELT Call before you dig. LEGEND EXISTING - - EAST OR ELE07RIC OVERHEAD TELEPHONE NORTH ...... OVERHEAD TV OVERHEAD - - _ - -- SOUTH OR SEWER SANITARY SEWER TELEPHONE . UNDERGROUND ELECTRIC UNDERGROUND WEST OR WATER - - UNDERGROUND ELECfR(C AND TELEFI%'.Mt _.._ PROPERTY UNE -- UNDERGROUND TELEPHONE - - - .RJGH7 OF WAY LINE -- UNDERGROUND TV -- --- STORM DRAIN WATER GAS _ TREE INFO .5 _ DIAMETER OF TRUNK IN FEET O OVERHEAD ELECTRIC 10 HEIGHT OF TREE IN FEET I = CANOPY DIAMETER IN FEET -., - --- OVERHEAD ELECTRICAND TELEPHONE 5U5 = ELEVATION AT BASE OF TREE ' (Meas. & Red.) 1/2" RB FD. BARKING DATA STANDARD PARKING 24 REQUIRED- 41 PROVIDED ACCESSIBLE PARKING 1 REQUIRED 2 PROVIDED TOTAL PARKING* 25 REQUIRED* 43 PROVIDED *GENERAL BUSINESS AND RETAIL SALES SHALL REQUIRE I.OSPACE PER THREE HUNDRED (300) SQUARE FEET OF GROSS FLOOR AREA. SITE DATA OVERALL DATA AREA 114.163 S.F. 2.62 AC EXISTING IMPERVIOUS AREA 7,480 6.55 °m' EXISTING PERVIOUS AREA 106,683 S.F. 93,45 % PROPOSED BUILDING AREA 7,382 6.47 % PROPOSED IMPERVIOUS AREA (NON-BLDG) 23.026 20.17 % TOTAL IMPERVIOUS AREA 30,408 S.F. 26,64 % PROPOSED PERVIOUS AREA 83,755 S.F. 73.36 % EXISTING ZONING R-2 PROPOSED ZONING: POD (C-3) FRONT YARD SETBACK 25-0" SIDE YARD SETBACK 15, REAR YARD SETBACK 25' MIN. SURFACE PARKING SETBACK MAX. BLDG. HEIGHT 35, PROPOSED PROPERTY UNEIRGHT OF WAY LINE CONCRETE CURB AND GUTTER. SEE DETAIL O1A/018, CURB INLET p BUILDING CONTROL POINT PROPOSED PARKING SPACES LIMITS OF SIDEWALKS AND CONCRETE APRONS (PER ARCH. PLANS) BERMUDA SOD TYPICAL PLANTING WITH QUANTITY AND KEY ' (SEE PLANT LIST) GENERAL SITE NOTES A. ALL DIMENSIONS SHOWN ARE TO THE FACE OF CURB UNLESS OTHERWISE NOTED, B. ALL CURB RETURN RADII SHALL BE S OR I O', AS SHOWN TYPICAL ON THIS PLAN, UNLESS OTHERWISE NOTED, C. UNLESS OTHERWISE SHOWN. CALLED OUT OR SPECIFIED HEREON OR WITHIN THE SPECIFICA1 IONS: ALL CURB AND GUTTER ADJACENT TO ASPHALT PAVING SHALL BE INSTALLED PER DETAIL OIA. ALL CURaING ADJACENT TCCONCRETE PAVING SHALL BE INSTALLED PER DETAIL 018. PAVEMENT SHALL BE INSTALLED IN - ACCvRDANCE WITH DETAIL 08A OVER THE ENTIRE PARKING LOT AREA AND ALL APPROACH DRIVES. ALL PARKING LOT STRIPING INCLUDING ACCESSIBLE AND VAN ACCESSIBLE SPACES SHALL BE PAINTED PER AUTOZONE DETAIL 3 (SEE SHEET C7). D. ALL PARKING LOT SIGN BASE SUPPORTS SHALL BE INSTALLED PER DETAIL 12F. E. ALL ACCESSIBLE PARKING STALLS SHALL HAVE SIGNAG£ INSTALLED PER AUTOZONE DETAIL 9 (SE SHEET C7). AUTOZONE GENERAL NOTES I. Proof roll building and all parking areas. Notify the Architect of any unacceptable areas. 2. Edge of new pavement to be flush with existing pavement. 3. All sidewalk curb and cutter street paving, curb cuts, driveway approaches,Tiandicap ramp, etc. constructed outside the property line in the right-of-wayy shall conform to all municipal and/or state speclf(catlon6 and requirements. 4. For areas outside the property lines, repair and/or replace all damage done to existing elements (sidewalks, paving, IandscapTng, etc.) as required by owner and/or governing authority. 5. For proposed utllfty locations, see the utility plan. Q SITE NOTES 12J FIRE LANE STRIPPING PER LOCAL CODES 16E MONUMENT SIGN. ❑ SITE DETAILS 01A TYPE A CONCRETE CURB AND GUTTER 02A PRECAST CONCRETE WHEEL STOP 08A STANDARD DUTY ASPHALT PAVING 50A TREE PLANTING 508 SHRUB PLANTING O AUTOZONE KEYNOTES (SEE SHEET C7 UNLESS SPECIFIED) 1 PIPE GUARD SEE DETAIL 11. 2 DUMPSTER LAYOUT SEE DETAILS 5,67,A 8. 3 SERVICE DOOR PLAN SEE DETAIL 10. 4 BOLLARD PLAN. SEE DETAIL 18 5 CONCRETE LIGHT POLE AND BASE SEE DETAILS 19 AND 20, AIM LIGHT FIXTURE IN DIRECTION INDICATED ON PHOTOMETRIC PLAN PHI. 6 NOT USED. 7 PAVING (SEE SHEET C6 FOR BOUNDARIES) -SEE DETAIL 2, 08A. 08B, OBC AND OBE. EXPANSION AND CONTROL JOINTS SEE DETAILS 13-14 MAXIMUM SPACING FOR CONTROL JOINTS IS 15' O.C. EACH WAY. 8 4' WIDE PARKING STRIPE PAINTED WHITE. 9 4' WIDE DIAGONAL STRIPES PAINTED WHITE AT 2' O.C. 10 HANDICAP PARKING SIGN SEE DETAIL 3 AND 9, G.C. TO PROVIDE ONE VAN ACCESSIBLE SIGN. 11 CONCRETE SIDEWALK SEE DETAIL 12 & 15 FOB SIDEWALKS AROUND BUILDING (NOTE DOWELING CONNECTION TO BUILDING FOR ALL SIOEWALKS/STOOPS) 12 ACCESSIBLE RAMP SEE DETAIL 1 . MAX. SLOPE 1:12 (8.33%) MAX. CROSS SLOPE 1 �60 (2%) TRUNCATED DOMES TO BE CONTRASTING COLOR. 13 LOADING AREA: SLOPE AT MAX. 2-1 /2% AWAY FROM BUILDING 14 YARD HYDRANT (SEE UTILITY PLAN) 15 INTERNATIONAL BARRIER FREE SYMBOL (SEE SHEET C7, DETAIL 4) �~ -A w N U (3) m 2 +-+ Z C) U �U o O vl N Q ¢' CS LU Z p LLI €mr ff n C0 } C0 c r R7 O Uo �7 p 0)( ��Lu V �F 6 � L 'Z L cn ro O i:OD N `[ LU ,d fQ c Q. SCALE: %i") 2. 3. 4. 5. ry6, f. DPOR: TCO PM: JPS DES: PTT ORIGINAL DATE 08-10-16 z PROTOTYPE SIZE 7N2-L 4 a �3 0 n