Loading...
HomeMy WebLinkAboutZ-9151 ApplicationPublic Works Review Comments Board of Adjustment Planning V�� 1 Agenda Date: 8/11/2016 Cad ' �1\ Z File Number Z-9150 East Village PCD 1200 - 1400 E. 6th St. 1 Due to the proposed use of the property, the Master Street Plan specifies that Shall Street for the frontage of this property must meet commercial street standards. Dedicate right-of-way to 30 feet from centerline. 2 Obtain a franchise agreement from Public Works (Bennie Nicolo, 371-4818) for the private improvements located in the right-of-way including pavers, colored concrete with score pattern, street trees, irrigation, electrical for lighting trees, etc... 3 With site development, provide design of street conforming to the Master Street Plan. Construct one-half street improvements to E. 6th St. adjacent to the subject property proposed for redevelopment including 5-foot sidewalks. The street improvements include the construction of a left turn lane or a portion of a left turn lane at Shall St. At the left turn lane, the street section should be 36 ft at its widest with 200 ft of stack and 100 ft of taper. Plans should reflect the left turn lane. 4 Property on the southside of E. 6th St, is shown to be of the same ownership and proposed to be redeveloped but no proposed street improvements are shown. Is a waiver being requested for those improvements? 5 Shall St. should be constructed with at least 20 ft curb radiuses. 6 The location of the pedestrian crossing on the west end of E. 6th St. should be moved to the Shall St. intersection due to limited sight distance from railroad bridge obstructions. 7 All driveways shall be concrete aprons per City Ordinance. 8 Repair or replace any curb and gutter or sidewalk that is damaged in the public right-of-way prior to occupancy. 9 A grading permit in accordance with section 29-186 (c) & (d) will be required prior to any land clearing or grading activities at the site. Other than residential subdivisions, site grading and drainage plans must be submitted and approved prior to the start of construction. Is the entire development proposed to be constructed in 1 phase or several phases. If constructed in several phases, is an advanced grading permit being requested? Street improvements cannot be deferred to the last phase. Show phases of construction. 10 Per Sec. 29-102 an evaluation should be conducted on the basis of existing downstream development and any analysis of stormwater runoff with and without the proposed development. If the proposed development will cause or increase downstream flooding conditions, provisions to minimize such flooding conditions should be included in the design of the storm management improvements. Such provisions may include downstream improvements and/or detention of stormwater runoff and its regulated discharge to the downstream storm drainage system. I l Storm water detention ordinance applies to this property. Maintenance of the detention pond and all private drainage improvements is the responsibility of the developer and/or property owner. Tuesday, July 19, 2016 Page 1 of 2 12 If disturbed area is 1 or more acres, obtain a NPDES storm water permit from the Arkansas Department of Environmental Quality prior to the start of construction. 13 Street Improvement plans shall include signage and striping. Public Works must approve completed plans prior to construction. 14 Street lights are required by Section 31-403 of the LR code. Provide plans for approval to Traffic Engineering. Street lights must be installed prior to platting/certificate of occupancy. Contact Traffic Engr 379-1813 (Greg Simmons) for more info. 15 Driveway locations and widths do not meet the traffic access and circulation requirements of Sections 30-43 and 31-210. The width of driveway must not exceed 36 feet. Driveway spacing on this commercial street is at least 250 ft from other driveways and intersections and 125 ft from side property lines. Variances must be requested. 16 "Stop" signage is shown on E. 6th St. Signage is not approved by this application and must meet traffic warrants and analysis requirements prior to installation. Tuesday, July 19, 2016 Page 2 of 2 Public Works Review Comments Board of Adjustment Planning Agenda Date: 8/11/2016 Z File Number 5-1777 The Parks Subdivision Pre Plat 9600 - 9700 Blk Mann Road 1 Mann Rd is classified on the Master Street Plan as a collector street. A dedication of right-of-way 30 feet from centerline will be required. 2 With site development, provide design of street conforming to the Master Street Plan. Construct one-half street improvement to Mann Rd including 5-foot sidewalks with planned development. The new back of curb should be located 18 ft from centerline. Additional widening to 24 ft from centerline, tapers, and striping should be provided for lane shifts and WB left turn lanes. Additional paving maybe required to comply with AASHTO guidelines. 3 Provide phasing plan for subdivision construction. Proposed Improvements Mann Road cannot be deferred to the last construction phase. 4 A grading permit in accordance with section 29-186 (c) & (d) will be required prior to any land clearing or grading activities at the site. Other than residential subdivisions, site grading and drainage plans must be submitted and approved prior to the start of construction. Is an advance grading variance requested to advance grade future phases of the subdivision with the issuance of a grading permit for the previous phase? If a variance is being requested, undisturbed buffers or berms should be maintained as found in the Land Alteration Regulations. 5 The proposed trail system layout will require pedestrians to walk in high traffic volume streets where sidewalks are required to be installed per the Master Street Plan per not proposed by this plan. Sidewalk should be provided adjacent to public streets and/or additional trails provided for better connectivity between homes and trails. Access considerations should be given for fenced in yards. 6 Provide a Sketch Grading and Drainage Plan per Sec. 29-186 due to the large drainage areas at the rear of lots. 7 Storm water detention ordinance applies to this property. Show the proposed location for stormwater detention facilities on the plan. Maintenance of the detention pond and all private drainage improvements is the responsibility of the developer and/or property owners association as detailed in the bill of assurance. 8 If disturbed area is 1 or more acres, obtain a NPDES storm water permit from the Arkansas Department of Environmental Quality prior to the start of construction. 9 Street lights are required by Section 31-403 of the LR code. Provide plans for approval to Traffic Engineering. Street lights must be installed prior to platting/certificate of occupancy. Contact Traffic Engr 379-1813 (Greg Simmons) for more info. 10 Provide a letter prepared by a registered engineer certifying the intersection sight distance at the intersection(s) comply with 2004 AASHTO Green Book standards. 1 I All public drainage easements must be unobstructed and access provided to the public right-of-way by constructed infrastructure and/or documented on the final plat. Monday, July 18, 2016 Page I of 2 12 All public drainage easements must contain drainage infrastructure approved by the City of Little Rock Public Works Department. 13 Access to detention ponds must be provided to the public right-of-way and/or access easement for future maintenance by the developer and/or local property owners' association. 14 Street names and street naming conventions must be approved by Public Works. Contact Glenn Haley at (501) 371-4537. Cascade Lane is a duplication and cannont be used. Big Bend Lane is too long in distance to be labeled as a lane. Consideration should be given to rename to "Drive". 14 If Big Bend Lane is constructed to a residential standard street, the minimum radius is 150 ft normal crown. 16 Additional traffic calming measures should be provided on Big Bend Lane on the east side of the development. 17 Big Bend Lane and Glacier Bay Drive should be constructed to a residential collector standard of 31 ft wide with sidewalk on 1 side or a trail system due to the expected volume of traffic. The minimum radius should be 275 ft normal crown or 235 ft super -elevated. 18 Due to the proposed configuration, there is limited sight distance at the intersection of Big Bend Lane and Sequoia Lane. 19 The secondary emergency access should be constructed to the existing pavement of Peace Valley Road. Monday, July 18, 2016 Page 2 of 2 Public Works Review Comments Planning Commission Board of Adjustment Agenda Date: 8-11-16 Z File Number LA-0071 12110 Stagecoach Road Advanced Grading Variance 12110 Stagecoach Rd 1 A grading permit in accordance with section 29-186 (c) & (d) will be required prior to any land clearing or grading activities at the site. Other than residential subdivisions, site grading and drainage plans must be submitted and approved prior to the start of construction. 2 If disturbed area is 1 or more acres, obtain a NPDES storm water permit from the Arkansas Department of Environmental Quality prior to the start of construction. 3 Storm water detention ordinance applies to this property to be provided in accordance with Chapter 29, Article IV. Design Criteria and Performance standards. 4 Per Sec. 29-197(2), the grading shall be expeditously completed in a time frame not to exceed one (1) year in duration from the time work commences to installation of all final erosion control measures and vegetation. Per Sec. 29-197(1 1), a permanent vegetative cover of suitable perennial grass shall be established over all disturbed areas. Where indicated by soil tests, pH adjustments and addition of fertilizer may be required. 6 Per Sec. 29-197(12), all erosion and stabilization controls, including permanent vegetation and plantings and stormwater detention systems are to be maintained by the responsible part for a growth. period of 2 years following completion of site grading. 7 Per Sec. 29-197(12), periodic mowing, generally 2 times per year or more often if required by CLR shall be provided to encourage perennial grass 8 Per Sec. 29-197(13), maintenance for the 2 year period shall be guaranteed through posting of cash, surety bond or letter of credit as referenced in Sec. 31-431(2) at the time of final inspection of the grading activities. 9 Per Sec. 29-197(14), all required federal, state, and local permits and approvals shall be obtained prior to commencement of land alteration activities. 10 A special Grading Permit for Flood Hazard Areas will be required per Sec. 8-283 prior to construction. 1 I Public works staff must be contacted for inspection for final approval of site stabilization prior to acceptance and relinquishment of maintenance bond. 12 Since no trees exist adjacent to Stagecoach Rd, temporary berms are required to be constructed adjacent to Stagecoach Road to obstruct views from Stagecoach Rd. Berms should also be constructed adjacent to other neighboring properties where a sufficient tree buffer to obstruct views is not established. 13 The site should be signed with a Land Alteration Variance sign acquired from Vince Floriani in Public Works Dept. Monday, July 18, 2016 Page I of 10 Z File Number S-1064-C Lot 16 Chambers Addition Replat 0 No comments Z File Number S-1424-G Sienna Lake Subdivision Blk 6 Pre Plat 18 Sheila Lane Sienna Lake Drive across from West Lake Lane 1 100 year overflow swales must be constructed and placed within public drainage easements. 2 All public drainage easements must be unobstructed and access provided to the public right-of-way by constructed infrastructure and/or documented on the final plat. 3 All public drainage easements must contain drainage infrastructure approved by the City of Little Rock Public Works Department. 4 If disturbed area is 1 or more acres, obtain a NPDES storm water permit from the Arkansas Department of Environmental Quality prior to the start of construction. 6 Repair or replace any curb and gutter or sidewalk that is damaged in the public right-of-way prior to occupancy. Z File Number S-1776 Mountain Valley Pre Plat 25616 Hwy 10 1 Hwy 10 is classified on the Master Street Plan as a principal arterial. Dedication of right-of-way to 55 feet from centerline will be required. 2 Pleasant Grove Road is classified on the Master Street Plan as a residential street. A dedication of right-of-way 34 feet from centerline will be required for a local residential street with open drainage. 3 With site development, provide design of street conforming to the Master Street Plan. Construct one-half street improvement to Hwy 10 including 5-foot sidewalks with planned development. AHTD has denied improvements to Hwy 10. A payment in -lieu of construction cannot be requested due to the property is outside the city limits. 4 With site development, provide design of street conforming to the Master Street Plan. Construct one-half street improvement to Pleasant Grove Road. Pleasant Grove Road should be constructed to a local residential street with open drainage as found in the MSP with 12 ft lanes, 6 ft pave shoulder, and open ditch. 5 The pedestrian trail system seems to promote pedestrians to walk in the streets to access the trails with very little connection or access points with fences constructed in rear yards. 6 Storm water detention ordinance applies to this property. Show the proposed location for stormwater detention facilities on the plan. Maintenance of the detention pond and all private drainage improvements is the responsibility of the developer and/or property owner association as defined in the bill of assurance. 7 If disturbed area is 1 or more acres, obtain a NPDES storm water permit from the Arkansas Department of Environmental Quality prior to the start of construction. 8 The property shows to be within the floodplain. Contact Pulaski County Planning pertaining to floodplain requirements. Monday, July 18, 2016 Page 2 of 10 9 Where is the proposed access for the treatment facility? 10 Provide a letter prepared by a registered engineer certifying the intersection sight distance at the intersection(s) comply with 2004 AASHTO Green Book standards. I 1 Since the street is proposed to be 24 ft in width, show on the plan the area of street where parking will be restricted to one side. 12 Access to detention ponds must be provided to the public right-of-way and/or access easement for future maintenance by the developer and/or local property owners' association. 13 100 year overflow swales must be constructed and placed within public drainage easements. 14 All public drainage easements must be unobstructed and access provided to the public right-of-way by constructed infrastructure and/or documented on the final plat. 15 Provide the phasing plan. Are street improvements to Pleasant Grove Road planned to be constructed with Phase 1? Z File Number 5-1777 The Parks Subdivision Pre Plat 9600 - 9700 Blk Mann Road I Mann Rd is classified on the Master Street Plan as a collector street. A dedication of right-of-way 30 feet from centerline will be required. 2 With site development, provide design of street conforming to the Master Street Plan. Construct one-half street improvement to Mann Rd including 5-foot sidewalks with planned development. The new back of curb should be located 18 ft from centerline. Additional widening to 24 ft from centerline, tapers, and striping should be provided for lane shifts and WB left turn lanes. Additional paving maybe required to comply with AASHTO guidelines. 3 Provide phasing plan for subdivision construction. Improvements to made to Mann Road cannot be deferred to the last construction phase. 4 A grading permit in accordance with section 29-186 (c) & (d) will be required prior to any land clearing or grading activities at the site. Other than residential subdivisions, site grading and drainage plans must be submitted and approved prior to the start of construction. Is an advance grading variance requested to advance grade future phases of the subdivision with the issuance of a grading permit for the previous phase. 5 The proposed trail system layout will require pedestrians to walk in high traffic volume streets where sidewalks are required to be installed per the Master Street Plan. Sidewalk should be provided adjacent to public streets and/or additional trails provided to connect pedestrians to the trail system. 6 Provide a Sketch Grading and Drainage Plan per Sec. 29-186 due to the large drainage areas at the rear of lots. 7 Storm water detention ordinance applies to this property. Show the proposed location for stormwater detention facilities on the plan. Maintenance of the detention pond and all private drainage improvements is the responsibility of the developer and/or property owners association as detailed in the bill of assurance. 8 If disturbed area is l or more acres, obtain a NPDES storm water permit from the Arkansas Department of Environmental Quality prior to the start of construction. 9 Street lights are required by Section 31-403 of the LR code. Provide plans for approval to Traffic Engineering. Street lights must be installed prior to platting/certificate of occupancy. Contact Traffic Engr 379-1813 (Greg Simmons) for more info. Monday, July 18, 2016 Page 3 of 10 10 Provide a letter prepared by a registered engineer certifying the intersection sight distance at the intersection(s) comply with 2004 AASHTO Green Book standards. I 1 All public drainage easements must be unobstructed and access provided to the public right-of-way by constructed infrastructure and/or documented on the final plat. 12 All public drainage easements must contain drainage infrastructure approved by the City of Little Rock Public Works Department. 13 Access to detention ponds must be provided to the public right-of-way and/or access easement for future maintenance by the developer and/or local property owners' association. 14 Street names and street naming conventions must be approved by Public Works. Contact Glenn Haley at (501) 371-4537. Cascade Lane is a duplication and cannont be used. Big Bend Lane is too long in distance to be labeled as a lane. Consideration should be given to rename to "Drive". Z File Number S-1778 Lots 1 and 2 Miles Add. Pre Plat 16604 Pride Valley RD 1 Pride Valley Rd is classified on the Master Street Plan as a collector street. A dedication of right-of- way 30 feet from centerline will be required. Z File Number Z-5178-D Lot I W Markham Parkway Add Rev PCD 13401 Chenal Parkway 1 Old Town Road is classified on the Master Street Plan as a collector street. A dedication of right-of- way 30 feet from centerline will be required. 2 Repair or replace any curb and gutter or sidewalk that is damaged in the public right-of-way prior to occupancy. Z File Number Z-5511-G Better Lawns and Gardens PCD 17605 Crystal Valley Road 1 Crystal Valley Rd is classified on the Master Street Plan as a principal arterial. Dedication of right-of- way to 55 feet from centerline will be required. 2 With site development, provide design of street conforming to the Master Street Plan. Construct one-half street improvement to Crystal Valley Rd with planned development. A 6 ft paved shoulder should be constructed along the property frontage. 3 All driveways shall be concrete aprons per City Ordinance. 4 Storm water detention ordinance applies to this property when additional impervious surface is constructed. Show the proposed location for stormwater detention facilities on the plan. Maintenance of the detention pond and all private drainage improvements is the responsibility of the developer and/or land owner. 5 Driveway locations and widths do not meet the traffic access and circulation requirements of Sections 30-43 and 31-210. Driveway spacing on arterial streets is at least 300 ft between driveways and 150 ft from side property line. The width of driveway must not exceed 36 feet. A variance is required to be obtained for the driveway locations. Monday, July 18, 2016 Page 4 of 10 6 Provide a letter prepared by a registered engineer certifying the intersection sight distance at the intersection(s) comply with 2004 AASHTO Green Book standards. Sight distance to the south maybe insufficient. Z File Number Z-5991-E Tract I The Village of Wellington PCD 700 Wellington Hills Rd 1 Sidewalks with appropriate handicap ramps are required to be installed adjacent to Wellington Hills Rd in accordance with Sec. 31-175 of the Little Rock Code and the Master Street Plan. 2 Repair or replace any curb and gutter or sidewalk that is damaged in the public right-of-way prior to occupancy. 3 A grading permit in accordance with section 29-186 (c) & (d) will be required prior to any land clearing or grading activities at the site. Other than residential subdivisions, site grading and drainage plans must be submitted and approved prior to the start of construction. 4 Storm water detention ordinance applies to this property. Show the proposed location for stormwater detention facilities on the plan. Maintenance of the detention pond and all private drainage improvements is the responsibility of the developer and/or 1 5 If disturbed area is 1 or more acres, obtain a NPDES storm water permit from the Arkansas Department of Environmental Quality prior to the start of construction. 6 Driveway locations and widths do not meet the traffic access and circulation requirements of Sections 30-43 and 31-210. Driveway spacing on an arterial street is 150 ft from the side property line and 300 ft from other driveways or intersections. A variance must be requested for the second driveway near the south property line. 7 Provide a letter prepared by a registered engineer certifying the intersection sight distance at the intersection(s) comply with 2004 AASHTO Green Book standards. 8 Damage to public and private property due to hauling operations or operation of construction related equipment from a nearby construction site shall be repaired by the responsible party prior to issuance of a certificate of occupancy. 9 The proposed parking on the southside of the building should be turned to either 45 or 60 degree to promote 1 directional flow from north to south. Z File Number Z-6973-G Lot 4, The Village at Col Glenn Rev PCD 13700 Block of David O Dodd Rd 1 David O Dodd Rd is classified on the Master Street Plan as a minor arterial. A dedication of right-of- way 45 feet from centerline will be required. 2 Lawson Rd Cutoff is classified on the Master Street Plan as a minor arterial. A dedication of right-of- way 45 feet from centerline will be required. 3 Due to the proposed use of the property, the Master Street Plan specifies that Lawson Road for the frontage of this property must meet commercial street standards. Dedicate right-of-way to 30 feet from centerline. 4 A 20 feet radial dedication of right-of-way is required at the intersection of Lawson Rd Cutoff and Lawson Road. 5 Due to an arteriall/arterial intersection, a 75 feet or more radial dedication of right-of-way is required at the intersection of David O Dodd Rd and Lawson Rd Cutoff. Monday, July 18, 2016 Page 5 of 10 6 With site development, provide design of street conforming to the Master Street Plan. Construct one-half street improvement to Lawson Rd including 5-foot sidewalks with planned development. The new back of curb should be located 18 ft from centerline. Staff cannot recommend approval of deferring boundary street improvements to the last phase of development. 7 With site development, provide design of street conforming to the Master Street Plan, Construct one-half street improvement to David O Dodd Rd including 5-foot sidewalks with planned development. The new back of curb should be located 29.5 ft from centerline. In addition due to the arterial/arterial intersection, a right turn turn should also be constructed on David O Dodd Road with 200 ft of stack and 100 ft of taper. The right turn lane will move the new back of curb to 40.5 ft from centerline at the intersection. Staff cannot recommend approval of deferring boundary street improvements to the last phase of a development. 8 With site development, provide design of street conforming to the Master Street Plan. Construct one-half street improvement to Lawson Road Cutoff including 5-foot sidewalks with planned development. The new back of curb should be placed 29.5 ft from centerline. Staff cannot recommend approval of deferring boundary street improvements to the last phase of development. 9 Provide access ramps at intersections. 10 A grading permit in accordance with section 29-186 (c) & (d) will be required prior to any land clearing or grading activities at the site. Other than residential subdivisions, site grading and drainage plans must be submitted and approved prior to the start of construction. Is advanced grading of future phases requested when construction is imminent on Phase 1 ? If advanced grading is proposed for future phases, berms or temporary undisturbed buffers should be maintained in conformance with Land Alteration Regulations. I I Storm water detention ordinance applies to this property. Show the proposed location for stormwater detention facilities on the plan. Maintenance of the detention pond and all private drainage improvements is the responsibility of the developer and/or property owner association. 12 If disturbed area is 1 or more acres, obtain a NPDES storm water permit from the Arkansas Department of Environmental Quality prior to the start of construction. 13 Street lights are required by Section 31-403 of the LR code. Provide plans for approval to Traffic Engineering. Street lights must be installed prior to platting/certificate of occupancy. Contact Traffic Engr 379-1813 (Greg Simmons) for more info. 14 Driveway locations and widths do not meet the traffic access and circulation requirements of Sections 30-43 and 31-210. The Lawson Road driveway is not located at least 125 ft from the side property line. The width of driveway must not exceed 36 feet. A variance must be requested. 15 Provide proposed truck route to unload vehicles within the site instead of on the public street. A couple of the turns appear to not be manueverable by a WB-60 vehicle. 16 Provide a letter prepared by a registered engineer certifying the intersection sight distance at the intersection(s) comply with 2004 AASHTO Green Book standards. 17 Damage to public and private property due to hauling operations or operation of construction related equipment from a nearby construction site shall be repaired by the responsible party prior to issuance of a certificate of occupancy. 18 Show locations of driveways on the south side of David O Dodd Road to determine any turning conflicts. Z File Number Z-8009-C Shackleford Warehouse 41 Zoning Site Plan Review South of 5310 Shackleford Rd Monday, July 18, 2016 Page 6 of 10 I Shackleford Rd is classified on the Master Street Plan as a minor arterial. A dedication of right-of- way 45 feet from centerline will be required. 2 With site development, provide design of street conforming to the Master Street Plan. Construct one-half street improvement to Shackleford Rd including 5-foot sidewalks with planned development. The new back of curb should be 29.5 ft from centerline. 3 Repair or replace any curb and gutter or sidewalk that is damaged in the public right-of-way prior to 4 A grading permit in accordance with section 29-186 (c) & (d) will be required prior to any land clearing or grading activities at the site. Other than residential subdivisions, site grading and drainage plans must be submitted and approved prior to the start of construction. 5 Are gates proposed to be installed. If so the gates can be located no closer than 20 ft from the new back of curb. 6 If disturbed area is I or more acres, obtain a NPDES storm water permit from the Arkansas Department of Environmental Quality prior to the start of construction. 7 Street lights are required by Section 31-403 of the LR code. Provide plans for approval to Traffic Engineering. Street lights must be installed prior to platting/certificate of occupancy. Contact Traffic Engr 379-1813 (Greg Simmons) for more info. 8 Hauling of fill material on or off site over municipal streets and roads requires approval prior to a grading permit being issued. Contact Public Works Traffic Engineering at 621 S. Broadway, (501) 379-1805 (Travis Herbner) for more information. 9 The proposed driveway locations create the opportunity for cut thru traffic and should be relocated or gates installed. 10 Damage to public and private property due to hauling operations or operation of construction related equipment from a nearby construction site shall be repaired by the responsible party prior to issuance of a certificate of occupancy. Z File Number Z-8233-B Longleaf Cove Lot 24 Rev PD-R 2 Longleaf Cove 0 No comments Z File Number Z-8872-A 510 - 524 Main Street Rev PCD 510 - 524 S. Main St. 0 No comments Z File Number Z-9105a Stone Crest Apartments PD-R 9700 Baseline Rd 1 A 20 feet radial dedication of right-of-way is required at the intersection of Herrick Lane and Baseline Rd. 2 Baseline Rd is classified on the Master Street Plan as a principal arterial. Dedication of right-of-way to 45 feet from centerline will be required. 3 A 20 feet radial dedication of right-of-way is required at the both sides of the intersection of Winston Drive and Baseline Rd. Monday, July 18, 2016 Page 7 of 10 of W 4 The old driveway not in use along with the culvert on Baseline Road should be removed. Contact Dan Ivy, AHTD, District 6 for permitting at 501-569-2171. 5 Repair or replace any curb and gutter or sidewalk that is damaged in the public right-of-way prior to occupancy. 6 Vehicles backing out into the public right-of-way are not permitted. Driveways exceeding 36 ft also are not permitted. By the use of wheel stops, landscape areas or fence, one (1) a one way exit driveway should be constructed near the north property line on Herrick Lane, The Herrick Lane driveway should not exceed 15 ft wide. The proposed parking should be angled on the west side the existing buildings. 7 The parking stalls on the northside of the existing building are only 7 ft wide. 8 Vehicles backing out into the public right-of-way are not permitted. Driveways exceeding 36 ft also are not permitted. By the use of wheel stops or landscape areas, a driveway should be constructed just south of the existing building at a location to provide efficient and safe vehicle movements. The driveways should be not exceed 26 ft. Due to the limit space to right-of-way, the asphalt pavement on the east side of the existing building on Winston Drive should be removed and replaced with sod and landscaping. 9 With site development on Lot 1, provide design of street conforming to the Master Street Plan. Construct curb and gutter on the west side of Winston Dr. 10 The owner and/or manager of each multi -family residence of 100 or more dwelling units shall provide recycling and encourage participation by the tenants, renters, or owners of each unit. Contact Melinda Glasgow at 371-4646 for more information. 1 1 With future site expansion or construction of new structures, provide design of street conforming to the Master Street Plan. Construct one-half street improvement to the boundary streets including foot sidewalks with planned development. 12 Obtain a franchise agreement from Public Works (Bennie Nicolo, 371-4818) for the private improvements including parking, parking aisles, fence, gates, and barriers located in the right-of- 13 Provide proposed striping plan for the parking lot on the east side of Winston Drive. 14 The call boxes should be located at least 30 ft from the back of the street curb. Z File Number Z-9149 15th and Park Lane PD-R 515 - 519 E. 15th St 1 A 20 feet radial dedication of right-of-way is required at the intersection of E. 15th St. and Park Lane. 2 The driveway apron on Park Lane should be narrowed to the width of the shared gravel driveway. Curb and gutter should be installed where driveway apron is removed. Z File Number Z-9150 East Village PCD 1200 - 1400 E. 6th St. Due to the proposed use of the property, the Master Street Plan specifies that Shall Street for the frontage of this property must meet commercial street standards. Dedicate right-of-way to 30 feet from centerline. Monday, July 18, 2016 Page 8 of 10 2 Obtain a franchise agreement from Public Works (Bennie Nicolo, 371-4818) for the private improvements located in the right-of-way including pavers, colored concrete with score pattern, street trees, irrigation, electrical for lighting trees, etc... 3 A bike lane is only shown on the south side of the street. The Master Bike Plan requires a minimum 6 ft wide bike lane measured from the back of curb on both sides of the street. 4 With construction of bike lanes, the minimum street width on 6th St. is 34 ft from back of curb to back of curb. 5 Shall St. should be at least 20 ft curb 6 Pedestrian crossing location 7 All driveways shall be concrete aprons r City Ordinance. 8 Repair or replace any curb and gutter �r sidewalk that is damaged in the public right-of-way prior to occupancy. J 9 A gr, ding permit in accordance th section 29-186 (c) & (d) will be required prior to any land cleari or grading activities at a site. Other than residential subdivisions, site grading and draina plans must be submi d and approved prior to the start of construction. Is the entire develop ent proposed to be onstructed in 1 phase or several phases. If constructed in several phases, is advanced grad g permit being requested? Street improvements cannot be deferred to the last nh . Show uh es of construction. 10 Per Sec. 29-1 2 an eva ation should be conducted on the basis of existing downstream development and any analys of st water runoff with and without the proposed development. If the proposed development wi 'ca se or increase downstream flooding conditions, provisions to minimize such flooding conditia should be included in the design of the storm management improvements. Such provisions may irAude downstream improvements and/or detention of stormwater runoff and its regulated disch� ge\to the downstream storm drainage system. 1 1 Storm water detentio ordinance applies to this property. Show the proposed location for stormwater detention F,Iilities o the plan. Maintenance of the detention pond and all private drainage improvements is the re onsibility of the developer and/or property owner. 12 If distur�bd area is 1 or more acres, obtain a NPDES storm water permit from the Arkansas Department of Environmeollal Quality prior to the start of construction. 13 Stree improvement plans shall include signage and striping. Public Works must approve completed pl s prior to construction. 14 Sheet lights are required by Section 31-403 of the LR code. Provide plans for approval to Traffic Engineering. Street lights must be installed prior to platting/certificate of occupancy. Contact Traffic Engr 379-1813 (Greg Simmons) for more info. 15 Driveway locations and widths do not meet the traffic access and circulation requirements of Sections 30-43 and 31-210. The width of driveway must not exceed 36 feet. Driveway spacing on this commercial street is at least 250 ft from other driveways and intersections and 125 ft from side property lines. Variances must be requested. Z File Number Z-9151 Porter PCD 9325 Hwy 10 1 Ferndale Cutoff is classified on the Master Street Plan as a principal arterial. Dedication of right-of- way to 55 feet from centerline will be required. At arterial -artri al intersections, an additional 10 ft of right-of-way should be dedicated for 250 ft in length for a future right turn lane. Monday, July 18, 2016 Page 9 of 10 2 Hwy 10 is classified on the Master Street Plan as a principal arterial. Dedication of right-of-way to 55 feet from centerline will be required. 3 A 100 feet radial dedication of right-of-way is required at the intersection of Ferndale Cutoff and Hwy 10. 4 Portions of the subject property shows to be within the regulatory floodplain. Contact Pulaski County Planning Dept. about specific conditions and regulations. 5 With future site development, provide design of street conforming to the Master Street Plan. Construct one-half street improvement to Hwy 10 and Ferndale Cutoff including 5-foot sidewalks with planned development. Monday, July 18, 2016 Page 10 of 10 Little Rock Wastewater Comments Project Number S-1064-C Project Name Project Type Lot 16 Chambers Addition Replat Project Number S-1424-G Project Name Project Type Sienna Lake Subdivision Preliminary Plat Block 6 Project Number S-1776 Project Name Project Type Mountain Valley Preliminary plat Project Number 5-1777 Project Name Project Type The Parks Subdivision Preliminary plat Project Number Z-1778 Project Name Project Type Lots 1 and 2 Miles Addition Preliminary plat Project Number Z-5178-D Project Name Project Type West Markham Parkway Revised PCD Addition Project Number Z-5511-G Project Name Project Type Better Lawns and Gardens Planned Development Commercial Project Number Z-5991-E Project Name Project Type Tract 1 The Villages at Planned Development Commercia Wellington Comment Made Sewer Available to this site, Comment Made Sewer main extension required with easements if new sewer service is required for this project. Capacity fee analysis required. Comment Made Outside Service Boundary - No Comment. Comment Made Sewer main extension required with easements if new sewer service is required for this project. Capacity Fee Analysis Required. Comment Made Outside Service Boundary - No Comment. Comment Made Sewer Available to this site. Comment Made Outside Service Boundary - No Comment. Comment Made Sewer Available to this site. Capacity Fee analysis required Friday, July 15, 2016 Page 1 of 2 Project Number Z-6973-G Project Name Project Type Lot 4, the Village at Col Planned Development Commercial Glenn Project Number Z-8009-C Project Name Project Type Shackleford Warehouse #1 Zoning Site plan review Project Number Z-8233-B Project Name Project Type Longleaf Cove Lot 24 Planned Development Residential Project Number Z-8872-A Project Name Project Type 510-524 Main Street Planned Development Commercial Project Number Z-9105 Project Name Project Type Stone Crest Apartments Planned Development Residential Project Number Z-9149 Project Name Project Type 15th and Park Lane Planned Development Residential Project Number Z-9150 Project Name Project Type East Village Planned Development Commercial Comment Made Sewer Available to this site. Capacity Fee analysis required Comment Made Sewer Available to this site. Comment Made Existing Sewer Easement must be retained Comment Made Sewer Available to this site. Capacity Fee analysis required Comment Made Sewer Available to this site. Comment Made Sewer main extension required with easements, in order that each separate dwelling must have its own sewer service. Comment Made Sewer Available to this site. Capacity Fee analysis required: EAD approval required if food prep is to be done on site. Project Number Z--9151 Project Name Project Type Comment Made Porter Planned Development Commercial Outside Service Boundary - No Comment. Friday, July 15, 2016 Page 2 of 2 PLANNING COMMISSION REVIEW CENTRAL ARKANSAS WATER 20 July 2016 NAME TYPE ISSUE COMMENTS TRACT 1 THE VILLAGE OF Z-5991-E All Central Arkansas Water requirements in WELLINGTON SHORT -FORM - effect at the time of request for water service PCD must be met. Please submit plans for water facilities and/or fire protection system to Central Arkansas Water for review. Plan revisions may be required after additional review. Contact Central Arkansas Water regarding procedures for installation of water facilities and/or fire service. Approval of plans by the Arkansas Department of Health Engineering Division and Little Rock Fire Department is required. A Capital Investment Charge based on the size of meter connection(s) will apply to this project in addition to normal charges. This fee will apply to all connections including metered connections off the private fire system. If there are facilities that need to be adjusted and/or relocated, contact Central Arkansas Water. That work would be done at the expense of the developer. Contact Central Arkansas Water regarding the size and location of the water meter. The facilities on -site will be private. When meters are planned off private lines, private facilities shall be installed to Central Arkansas Water's material and construction specifications and installation will be inspected by an engineer, licensed to practice in the State of Arkansas. Execution of Customer Owned Line Agreement is required. Due to the nature of this facility, installation of an approved reduced pressure zone backflow preventer assembly (RPZ) is required on the domestic water service. This assembly must be installed prior to the first point of use. Central Arkansas Water (CAW) requires that upon installation of the RPZA, successful tests of the assembly must be completed by a Certified Assembly Tester licensed by the State of Arkansas and approved by CAW. The test results must be sent to CAW's Cross Connection Section NAME TYPE ISSUE COMMENTS within ten days of installation and annually thereafter. Contact the Cross Connection Section at 377-1226 if you would like to discuss backflow prevention requirements for this project. Fire sprinkler systems which do not contain additives such as antifreeze shall be isolated with a double detector check valve assembly. If additives are used, a reduced pressure zone backflow preventer shall be required. PLANNING COMMISSION REVIEW CENTRAL ARKANSAS WATER 15 July 2016 NAME TYPE ISSUE COMMENTS SIENNA LAKE DUBDIVISION S-1424-G All Central Arkansas Water requirements in BLOCK 6 PRELIMINARY PLAT effect at the time of request for water service must be met. The Little Rock Fire Department needs to evaluate this site to determine whether additional public and/or private fire hydrant(s) will be required. If additional fire hydrant(s) are required, they will be installed at the Developer's expense. Please submit plans for water facilities and/or fire protection system to Central Arkansas Water for review. Plan revisions may be required after additional review. Contact Central Arkansas Water regarding procedures for installation of water facilities and/or fire service. Approval of plans by the Arkansas Department of Health Engineering Division and Little Rock Fire Department is required. If there are facilities that need to be adjusted and/or relocated, contact Central Arkansas Water. That work would be done at the expense of the developer. This development will have minor impact on the existing water distribution system. Proposed water facilities will be sized to provide adequate pressure and fire protection. NAME TYPE ISSUE COMMENTS BETTER LAWNS AND ARDENS SHORT -FORM PCD LOTS 1 & 2 MILES ADDITION PRELIMINARY PLAT LONGLEAF COVE LOT 24 REVISED SHORT -FORM PD-R 15TH AND PARK LANE SHORT - FORM PD-R Z-5511-G Due to the nature of this facility, installation of an approved reduced pressure zone backflow preventer assembly (RPZ) is required on the domestic water service. This assembly must be installed prior to the first point of use. Central Arkansas Water (CAW) requires that upon installation of the RPZA, successful tests of the assembly must be completed by a Certified Assembly Tester licensed by the State of Arkansas and approved by CAW. The test results must be sent to CAW's Cross Connection Section within ten days of installation and annually thereafter. Contact the Cross Connection Section at 377-1226 if you would like to discuss backflow prevention requirements for this project. NO OBJECTIONS; All Central Arkansas Water requirements in effect at the time of request for water service must be met. S-1778 NO OBJECTIONS; All Central Arkansas Water requirements in effect at the time of request for water service must be met. Z-8233-B NO OBJECTIONS; All Central Arkansas Water requirements in effect at the time of request for water service must be met. Z-9149 NO OBJECTIONS; All Central Arkansas Water requirements in effect at the time of request for water service must be met. NAME TYPE ISSUE COMMENTS 7 7- THE PARKS SUBDIVISION S-1777 All Central Arkansas Water requirements in PRELIMINARY PLAT effect at the time of request for water service must be met. A water main extension will be needed to provide water service to this property. Please submit plans for water facilities to Central Arkansas Water for review. Plan revisions may be required after additional review. Contact Central Arkansas Water regarding procedures for installation of water facilities. Approval of plans by Central Arkansas Water, the Arkansas Department of Health Engineering Division and Little Rock Fire Department is required. This development will have minor impact on the existing water distribution system. Proposed water facilities will be sized to provide adequate pressure and fire protection. If there are facilities that need to be adjusted and/or relocated, contact Central Arkansas Water. That work would be done at the expense of the developer. Additional fire hydrant(s) will be required. Contact the Little Rock Fire Department to obtain information regarding the required placement of the hydrant(s) and contact Central Arkansas Water regarding procedures for installation of the hydrant(s). A Capital Investment Charge based on the size of meter connection(s) will apply to this project in addition to normal charges NAME TYPE ISSUE COMMENTS LOT 1 R WEST MARKHAM Z-5178-D All Central Arkansas Water requirements in PARKWAY ADDITION REVISED effect at the time of request for water service SHORT -FORM PCD must be met. The Little Rock Fire Department needs to evaluate this site to determine whether additional public and/or private fire hydrant(s) will be required. If additional fire hydrant(s) are required, they will be installed at the Developer's expense. Please submit plans for water facilities and/or fire protection system to Central Arkansas Water for review. Plan revisions may be required after additional review. Contact Central Arkansas Water regarding procedures for installation of water facilities and/or fire service. Approval of plans by the Arkansas Department of Health Engineering Division and Little Rock Fire Department is required. If there are facilities that need to be adjusted and/or relocated, contact Central Arkansas Water. That work would be done at the expense of the developer. The facilities on -site will be private. When meters are planned off private lines, private facilities shall be installed to Central Arkansas Water's material and construction specifications and installation will be inspected by an engineer, licensed to practice in the State of Arkansas. Execution of Customer Owned Line Agreement is required. Due to the nature of this facility, installation of an approved reduced pressure zone backflow preventer assembly (RPZ) is required on the domestic water service. This assembly must be installed prior to the first point of use. Central Arkansas Water (CAW) requires that upon installation of the RPZA, successful tests of the assembly must be completed by a Certified Assembly Tester licensed by the State of Arkansas and approved by CAW. The test results must be sent to CAW's Cross Connection Section within ten days of installation and annually thereafter. Contact the Cross Connection Section at 377-1226 if you would like to discuss backflow prevention requirements for this project. Fire sprinkler systems which do not contain additives such as antifreeze shall be isolated NAME LOT 16 CHAMBERS ADDITION REPLAT TYPE ISSUE COMMENTS with a double detector check valve assembly. If additives are used, a reduced pressure zone backflow preventer shall be required. S-1064-C NO OBJECTIONS; All Central Arkansas Water requirements in effect at the time of request for water service must be met. F NAME TYPE ISSUE COMMENTS 510-524 MAIN STREET REVISED Z-8872-A All Central Arkansas Water requirements in SHORT -FORM PCD effect at the time of request for water service must be met. Please submit plans for water facilities and/or fire protection system to Central Arkansas Water for review. Plan revisions may be required after additional review. Contact Central Arkansas Water regarding procedures for installation of water facilities and/or fire service. Approval of plans by the Arkansas Department of Health Engineering Division and Little Rock Fire Department is required. If there are facilities that need to be adjusted and/or relocated, contact Central Arkansas Water. That work would be done at the expense of the developer. Contact Central Arkansas Water regarding the size and location of the water meter. The facilities on -site will be private. When meters are planned off private lines, private facilities shall be installed to Central Arkansas Water's material and construction specifications and installation will be inspected by an engineer, licensed to practice in the State of Arkansas. Execution of Customer Owned Line Agreement is required. Due to the nature of this facility, installation of an approved reduced pressure zone backflow preventer assembly (RPZ) is required on the domestic water service. This assembly must be installed prior to the first point of use. Central Arkansas Water (CAW) requires that upon installation of the RPZA, successful tests of the assembly must be completed by a Certified Assembly Tester licensed by the State of Arkansas and approved by CAW. The test results must be sent to CAW's Cross Connection Section within ten days of installation and annually thereafter. Contact the Cross Connection Section at 377-1226 if you would like to discuss backflow prevention requirements for this project. Fire sprinkler systems which do not contain additives such as antifreeze shall be isolated with a double detector check valve assembly. If additives are used, a reduced pressure zone backflow preventer shall be required. NAME _ W TYPE ISSUE COMMENTS STONE CREST APARTMENTS Z-9105 SHORT -FORM PD-R All Central Arkansas Water requirements in effect at the time of request for water service must be met. Please submit plans for water facilities and/or fire protection system to Central Arkansas Water for review. Plan revisions may be required after additional review. Contact Central Arkansas Water regarding procedures for installation of water facilities and/or fire service. Approval of plans by the Arkansas Department of Health Engineering Division and Little Rock Fire Department is required. If there are facilities that need to be adjusted and/or relocated, contact Central Arkansas Water. That work would be done at the expense of the developer. The facilities on -site will be private. When meters are planned off private lines, private facilities shall be installed to Central Arkansas Water's material and construction specifications and installation will be inspected by an engineer, licensed to practice in the State of Arkansas. Execution of Customer Owned Line Agreement is required. Due to the nature of this facility, installation of an approved reduced pressure zone backflow preventer assembly (RPZ) is required on the domestic water service. This assembly must be installed prior to the first point of use. Central Arkansas Water (CAW) requires that upon installation of the RPZA, successful tests of the assembly must be completed by a Certified Assembly Tester licensed by the State of Arkansas and approved by CAW. The test results must be sent to CAW's Cross Connection Section within ten days of installation and annually thereafter. Contact the Cross Connection Section at 377-1226 if you would like to discuss backflow prevention requirements for this project. Fire sprinkler systems which do not contain additives such as antifreeze shall be isolated with a double detector check valve assembly. If additives are used, a reduced pressure zone backflow preventer shall be required. NAME TYPE ISSUE COMMENTS EAST VILLAGE SHORT -FORM Z-9150 All Central Arkansas Water requirements in PCD effect at the time of request for water service must be met. The Little Rock Fire Department needs to evaluate this site to determine whether additional public and/or private fire hydrant(s) will be required. If additional fire hydrant(s) are required, they will be installed at the Developer's expense. Please submit plans for water facilities and/or fire protection system to Central Arkansas Water for review. Plan revisions may be required after additional review. Contact Central Arkansas Water regarding procedures for installation of water facilities and/or fire service. Approval of plans by the Arkansas Department of Health Engineering Division and Little Rock Fire Department is required. A Capital Investment Charge based on the size of meter connection(s) will apply to this project in addition to normal charges. This fee will apply to all connections including metered connections off the private fire system. If there are facilities that need to be adjusted and/or relocated, contact Central Arkansas Water. That work would be done at the expense of the developer. Contact Central Arkansas Water regarding the size and location of the water meter. The facilities on -site will be private. When meters are planned off private lines, private facilities shall be installed to Central Arkansas Water's material and construction specifications and installation will be inspected by an engineer, licensed to practice in the State of Arkansas. Execution of Customer Owned Line Agreement is required. Due to the nature of this facility, installation of an approved reduced pressure zone backflow preventer assembly (RPZ) is required on the domestic water service. This assembly must be installed prior to the first point of use. Central Arkansas Water (CAW) requires that upon installation of the RPZA, successful tests of the assembly must be completed by a Certified Assembly Tester licensed by the State of Arkansas and M NAME TYPE ISSUE COMMENTS f approved by CAW. The test results must be sent to CAW's Cross Connection Section within ten days of installation and annually thereafter. Contact the Cross Connection Section at 377-1226 if you would like to discuss backflow prevention requirements for this project. Fire sprinkler systems which do not contain additives such as antifreeze shall be isolated with a double detector check valve assembly. If additives are used, a reduced pressure zone backflow preventer shall be required. N NAME TYPE ISSUE COMMENTS SHACKLEFORD WAREHOUSE #1 Z-8009-C ZONING SITE PLAN REVIEW All Central Arkansas Water requirements in effect at the time of request for water service must be met. A water main extension will be needed to provide water service to this property. Please submit plans for water facilities and/or fire protection system to Central Arkansas Water for review. Plan revisions may be required after additional review. Contact Central Arkansas Water regarding procedures for installation of water facilities and/or fire service. Approval of plans by the Arkansas Department of Health Engineering Division and Little Rock Fire Department is required. A Capital Investment Charge based on the size of meter connection(s) will apply to this project in addition to normal charges. This fee will apply to all connections including metered connections off the private fire system. If there are facilities that need to be adjusted and/or relocated, contact Central Arkansas Water. That work would be done at the expense of the developer. Contact Central Arkansas Water regarding the size and location of the water meter. The facilities on -site will be private. When meters are planned off private lines, private facilities shall be installed to Central Arkansas Water's material and construction specifications and installation will be inspected by an engineer, licensed to practice in the State of Arkansas. Execution of Customer Owned Line Agreement is required. Due to the nature of this facility, installation of an approved reduced pressure zone backflow preventer assembly (RPZ) is required on the domestic water service. This assembly must be installed prior to the first point of use. Central Arkansas Water (CAW) requires that upon installation of the RPZA, successful tests of the assembly must be completed by a Certified Assembly Tester licensed by the State of Arkansas and approved by CAW. The test results must be sent to CAW's Cross Connection Section within ten days of installation and annually thereafter. Contact the Cross Connection 10 NAME PORTER SHORT -FORM PCQ TYPE ISSUE COMMENTS Section at 377-1226 if you would like to discuss backflow prevention requirements for this project. Fire sprinkler systems which do not contain additives such as antifreeze shall be isolated with a double detector check valve assembly. If additives are used, a reduced pressure zone backflow preventer shall be required. Z-9151 NO OBJECTIONS; All Central Arkansas Water requirements in effect at the time of request for water service must be met. 11 NAME TYPE ISSUE COMMENTS THE VILLAGE AT COLONEL Z-6973-G All Central Arkansas Water requirements in GLENN REVISED SHORT FORM effect at the time of request for water service PCD must be met. The Little Rock Fire Department needs to evaluate this site to determine whether additional public and/or private fire hydrant(s) will be required. If additional fire hydrant(s) are required, they will be installed at the Developer's expense. Please submit plans for water facilities and/or fire protection system to Central Arkansas Water for review. Plan revisions may be required after additional review. Contact Central Arkansas Water regarding procedures for installation of water facilities and/or fire service. Approval of plans by the Arkansas Department of Health Engineering Division and Little Rock Fire Department is required. A Capital Investment Charge based on the size of meter connection(s) will apply to this project in addition to normal charges. This fee will apply to all connections including metered connections off the private fire system. If there are facilities that need to be adjusted and/or relocated, contact Central Arkansas Water. That work would be done at the expense of the developer. Contact Central Arkansas Water regarding the size and location of the water meter. The facilities on -site will be private. When meters are planned off private lines, private facilities shall be installed to Central Arkansas Water's material and construction specifications and installation will be inspected by an engineer, licensed to practice in the State of Arkansas. Execution of Customer Owned Line Agreement is required. Due to the nature of this facility, installation of an approved reduced pressure zone backflow preventer assembly (RPZ) is required on the domestic water service. This assembly must be installed prior to the first point of use. Central Arkansas Water (CAW) requires that upon installation of the RPZA, successful tests of the assembly must be completed by a Certified Assembly Tester licensed by the State of Arkansas and 12 NAME TYPE ISSUE COMMENTS approved by CAW. The test results must be sent to CAW's Cross Connection Section within ten days of installation and annually thereafter. Contact the Cross Connection Section at 377-1226 if you would like to discuss backflow prevention requirements for this project. Fire sprinkler systems which do not contain additives such as antifreeze shall be isolated with a double detector check valve assembly. If additives are used, a reduced pressure zone backflow preventer shall be required. MOUNTAIN VALLEY S-1776 All Central Arkansas Water requirements in PRELIMINARY PLAT effect at the time of request for water service must be met. A water main extension will be needed to provide water service to this property. Please submit plans for water facilities to Central Arkansas Water for review. Plan revisions may be required after additional review. Contact Central Arkansas Water regarding procedures for installation of water facilities. Approval of plans by Central Arkansas Water, the Arkansas Department of Health Engineering Division and Little Rock Fire Department is required. This development will have minor impact on the existing water distribution system. Proposed water facilities will be sized to provide adequate pressure and fire protection. If there are facilities that need to be adjusted and/or relocated, contact Central Arkansas Water. That work would be done at the expense of the developer. Additional fire hydrant(s) will be required. Contact the Little Rock Fire Department to obtain information regarding the required placement of the hydrant(s) and contact Central Arkansas Water regarding procedures for installation of the hydrant(s) A Capital Investment Charge based on the size of meter connection(s) will apply to this project in addition to normal charges. FBI To: Donna James From: Captain Tony Rhodes / Captain John Hogue: Fire Marshal Comment for the following Locations: Z-5991-E 700 Wellington Hills Full plan review. Canopy must be 13' 6". Maintain Access: Fire Hydrants. Date: July 14, 2016 Maintain fire apparatus access roads at fire hydrant locations as per Appendix D of the 2012 Arkansas Fire Prevention Code Vol. 1 Section D103.1 Access road width with a hydrant. Where a fire hydrant is located on a fire apparatus access road, the minimum road width shall be 26 feet, exclusive of shoulders. Grade Maintain fire apparatus access roads as per Appendix D of the 2012 Arkansas Fire Prevention Code Vol. 1 Section D103.2 Grade. Fire apparatus access roads shall not exceed 10 percent in grade except as approved by the fire chief. Loading Maintain fire apparatus access road design as per Appendix D of the 2012 Arkansas Fire Prevention Code Vol. 1 Section D102.1 Access and loading. Facilities, buildings or portions of buildings hereafter constructed shall be accessible to fire department apparatus by way of an approved fire apparatus access road with an asphalt, concrete or other approved driving surface capable of supporting the imposed load of fire apparatus weighing at least 75,000 pounds. Fire Hydrants Locate Fire Hydrants as per Appendix C of the 2012 Arkansas Fire Prevention Code. Section C101— C105, in conjunction with Central Arkansas Water (Daniel Tull 501-377-1245) and the Little Rock Fire Marshals Office (Capt. Tony Rhodes 501-918-3757 or Capt. John Hogue 501-918-3754). Number and Distribution of Fire Hydrants as per Table C105.1. S-1424-G Sienna Lake Drive All houses must be sprinkled or have a second way into the subdivision. One- or Two -Family Residential Developments. As per Appendix D, Section D107.1 of the Arkansas Fire Prevention Code Vol. 1, One- or Two -Family dwelling residential developments. Developments of one- or two-family dwellings where the number of dwelling units exceeds 30 shall be provided with two separate and approved fire apparatus access roads, and shall meet the requirements of Section D104.3. Exceptions: Where there are more than 30 dwelling units on a single public or private fire apparatus access road and al dwelling units are equipped throughout with an approved automatic sprinkler system in accordance with Section 903.3.1.1, 903.3.1.2 or 903.3.1.3 of the Arkansas Fire Code, access from two directions shall not be required. The number of dwelling units on a single fire apparatus access road shall not be increased unless fire apparatus access roads will connect with future development, as determined by the fire code official. Z-5511-G 17605 Crystal Valley Road Maintain Access: Fire Hydrants. Maintain fire apparatus access roads at fire hydrant locations as per Appendix D of the 2012 Arkansas Fire Prevention Code Vol. 1 Section D103.1 Access road width with a hydrant. Where a fire hydrant is located on a fire apparatus access road, the minimum road width shall be 26 feet, exclusive of shoulders. Grade Maintain fire apparatus access roads as per Appendix D of the 2012 Arkansas Fire Prevention Code Vol. 1 Section D103.2 Grade. Fire apparatus access roads shall not exceed 10 percent in grade except as approved by the fire chief. Loading Maintain fire apparatus access road design as per Appendix D of the 2012 Arkansas Fire Prevention Code Vol. 1 Section D102.1 Access and loading. Facilities, buildings or portions of buildings hereafter constructed shall be accessible to fire department apparatus by way of an approved fire apparatus access road with an asphalt, concrete or other approved driving surface capable of supporting the imposed load of fire apparatus weighing at least 75,000 pounds. Commercial and Industrial Developments — 2 means of access. - Maintain fire apparatus access roads as per Appendix D of the 2012 Arkansas Fire Prevention Code Vol. 1 Section D104.1 Buildings exceeding three stories or 30 feet in height. Building or facilities exceeding 30 feet or three stories in height shall have at least two means of fire apparatus access for each structure. Section D104.2 Building exceeding 62,000 square feet in area. Buildings or facilities having a gross building area of more than 62,000 square feet shall be provide with two separate and approved fire apparatus access roads. Exception: Projects having a gross building area of up to 124,000 square feet that have a single approved fire apparatus access road when all building are equipped throughout with approved automatic sprinkler systems. D104.3 Remoteness. Where two fire apparatus access roads are required, they shall be placed a distance apart equal to not less than one half of the length of the maximum overall diagonal dimension of the lot or area to be served, measured in a straight line between accesses. Gates Maintain fire apparatus access road gates as per Appendix D of the 2012 Arkansas Fire Prevention Code Vol. 1 Section D103.5 Fire apparatus access road gates. Gates securing the fire apparatus access roads shall comply with all of the following criteria: 1. Minimum gate width shall be 20 feet. 2. Gates shall be of swinging or sliding type. 3. Construction of gates shall be of material that allow manual operation by one person. 4. Gate components shall be maintained in an operable condition at all times and replaces or repaired when defective. 5. Electric gates shall be equipped with a means of opening the gate by fire department personnel for emergency access. Emergency opening devices shall be approved by the fire code official. 6. Manual opening gates shall not be locked with a padlock or chain and padlock unless they are capable of being opened by means of forcible entry tools or when a key box containing the keys to the lock is installed at the gate location. 7. Locking device specifications shall be submitted for approval \by the fire code official 8. Electric gate operators, where provided, shall be listed in accordance with UL 325. 9. Gates, intended for automatic operation shall be designed, constructed and installed to comply with requirements of ASTM F 2200. Fire Hydrants Locate Fire Hydrants as per Appendix C of the 2012 Arkansas Fire Prevention Code. Section C101— C105, in conjunction with Central Arkansas Water (Daniel Tull 501-377-1245) and the Little Rock Fire Marshals Office (Capt. Tony Rhodes 501-918-3757 or Capt. John Hogue 501-918-3754). Number and Distribution of Fire Hydrants as per Table C105.1. S-1778 16604 Pride Vail No comment Z-8233-B #2 Longleaf Cove No comment Z-9149 151" and Park lane No comment S-1777 9600-9700 Mann Road Maintain Access: Fire Hydrants. Maintain fire apparatus access roads at fire hydrant locations as per Appendix D of the 2012 Arkansas Fire Prevention Code Vol. 1 Section D103.1 Access road width with a hydrant. Where a fire hydrant is located on a fire apparatus access road, the minimum road width shall be 26 feet, exclusive of shoulders. Grade Maintain fire apparatus access roads as per Appendix D of the 2012 Arkansas Fire Prevention Code Vol. 1 Section D103.2 Grade. Fire apparatus access roads shall not exceed 10 percent in grade except as approved by the fire chief. Loading Maintain fire apparatus access road design as per Appendix D of the 2012 Arkansas Fire Prevention Code Vol. 1 Section D102.1 Access and loading. Facilities, buildings or portions of buildings hereafter constructed shall be accessible to fire department apparatus by way of an approved fire apparatus access road with an asphalt, concrete or other approved driving surface capable of supporting the imposed load of fire apparatus weighing at least 75,000 pounds. Dead Ends. Maintain fire apparatus access roads at dead end locations as per Appendix D of the 2012 Arkansas Fire Prevention Code Vol. 1 Section D103.4 Dead Ends. Dead-end fire apparatus access roads in excess of 150 feet shall be provided with width and turnaround provisions in accordance with Table D103.4. Requirements for Dead-end fire apparatus access roads. Gates Maintain fire apparatus access road gates as per Appendix D of the 2012 Arkansas Fire Prevention Code Vol. 1 Section D103.5 Fire apparatus access road gates. Gates securing the fire apparatus access roads shall comply with all of the following criteria: 1. Minimum gate width shall be 20 feet. 2. Gates shall be of swinging or sliding type. 3. Construction of gates shall be of material that allow manual operation by one person. 4. Gate components shall be maintained in an operable condition at all times and replaces or repaired when defective. 5. Electric gates shall be equipped with a means of opening the gate by fire department personnel for emergency access. Emergency opening devices shall be approved by the fire code official. 6. Manual opening gates shall not be locked with a padlock or chain and padlock unless they are capable of being opened by means of forcible entry tools or when a key box containing the keys to the lock is installed at the gate location. 7. Locking device specifications shall be submitted for approval \by the fire code official 8. Electric gate operators, where provided, shall be listed in accordance with UL 325. 9. Gates, intended for automatic operation shall be designed, constructed and installed to comply with requirements of ASTM F 2200. One- or Two-Familv Residential Developments. As per Appendix D, Section D107.1 of the Arkansas Fire Prevention Code Vol. 1, One- or Two -Family dwelling residential developments. Developments of one- or two-family dwellings where the number of dwelling units exceeds 30 shall be provided with two separate and approved fire apparatus access roads, and shall meet the requirements of Section D104.3. Exceptions: 1. Where there are more than 30 dwelling units on a single public or private fire apparatus access road and al dwelling units are equipped throughout with an approved automatic sprinkler system in accordance with Section 903.3.1.1, 903.3.1.2 or 903.3.1.3 of the Arkansas Fire Code, access from two directions shall not be required. 2. The number of dwelling units on a single fire apparatus access road shall not be increased unless fire apparatus access roads will connect with future development, as determined by the fire code official. Fire Hydrants Locate Fire Hydrants as per Appendix C of the 2012 Arkansas Fire Prevention Code. Section C101— C105, in conjunction with Central Arkansas Water (Daniel Tull 501-377-1245) and the Little Rock Fire Marshals Office (Capt. Tony Rhodes 501-918-3757 or Capt. John Hogue 501-918-3754). Number and Distribution of Fire Hydrants as per Table C105.1. Z-5178-D 13401 Chenal Parkwa No comment S-1064-C Fire Hydrants. Maintain fire apparatus access roads at fire hydrant locations as per Appendix D of the 2012 Arkansas Fire Prevention Code Vol. 1 Section D103.1 Access road width with a hydrant. Where a fire hydrant is located on a fire apparatus access road, the minimum road width shall be 26 feet, exclusive of shoulders. Loading Maintain fire apparatus access road design as per Appendix D of the 2012 Arkansas Fire Prevention Code Vol. 1 Section D102.1 Access and loading. Facilities, buildings or portions of buildings hereafter constructed shall be accessible to fire department apparatus by way of an approved fire apparatus access road with an asphalt, concrete or other approved driving surface capable of supporting the imposed load of fire apparatus weighing at least 75,000 pounds. Fire Hydrants Locate Fire Hydrants as per Appendix C of the 2012 Arkansas Fire Prevention Code. Section C101— C105, in conjunction with Central Arkansas Water (Daniel Tull 501-377-1245) and the Little Rock Fire Marshals Office (Capt. Tony Rhodes 501-918-3757 or Capt. John Hogue 501-918-3754). Number and Distribution of Fire Hydrants as per Table C105.1. Z-8872-A 510-524 South Main Street Full Plan review Z-9105 9700 Baseline Road Full Plan review Z-9150 1200-1400 Blocks of East 6th Full Plan review Z-8009-C located south of 5310 Shackleford Full Plan review Z-9151 Hwy 10 and Ferndale Cutoff Road, No Comments S-1776 25616 Highway 10 Maintain Access: Fire Hydrants. Maintain fire apparatus access roads at fire hydrant locations as per Appendix D of the 2012 Arkansas Fire Prevention Code Vol. 1 Section D103.1 Access road width with a hydrant. Where a fire hydrant is located on a fire apparatus access road, the minimum road width shall be 26 feet, exclusive of shoulders. Grade Maintain fire apparatus access roads as per Appendix D of the 2012 Arkansas Fire Prevention Code Vol. 1 Section D103.2 Grade. Fire apparatus access roads shall not exceed 10 percent in grade except as approved by the fire chief. Loading Maintain fire apparatus access road design as per Appendix D of the 2012 Arkansas Fire Prevention Code Vol. 1 Section D102.1 Access and loading. Facilities, buildings or portions of buildings hereafter constructed shall be accessible to fire department apparatus by way of an approved fire apparatus access road with an asphalt, concrete or other approved driving surface capable of supporting the imposed load of fire apparatus weighing at least 75,000 pounds. One- or Two -Family Residential Developments. As per Appendix D, Section D107.1 of the Arkansas Fire Prevention Code Vol. 1, One- or Two -Family dwelling residential developments. Developments of one- or two-family dwellings where the number of dwelling units exceeds 30 shall be provided with two separate and approved fire apparatus access roads, and shall meet the requirements of Section D104.3. Exceptions: 1. Where there are more than 30 dwelling units on a single public or private fire apparatus access road and al dwelling units are equipped throughout with an approved automatic sprinkler system in accordance with Section 903.3.1.1, 903.3.1.2 or 903.3.1.3 of the Arkansas Fire Code, access from two directions shall not be required. 2. The number of dwelling units on a single fire apparatus access road shall not be increased unless fire apparatus access roads will connect with future development, as determined by the fire code official. Fire Hydrants Locate Fire Hydrants as per Appendix C of the 2012 Arkansas Fire Prevention Code. Section C101— C105, in conjunction with Central Arkansas Water (Daniel Tull 501-377-1245) and the Little Rock Fire Marshals Office (Capt. Tony Rhodes 501-918-3757 or Capt. John Hogue 501-918-3754). Number and Distribution of Fire Hydrants as per Table C105.1. Z-6973-G Full plan review Regards, Captain Rhodes and Captain Hogue Office: 918-3710 Ak 'ti■a�hr "Entergy July 8, 2016 City of Little Rock Department of Planning and Development ATTN: Ms. Donna James, AICP 723 West Markham Street Little Rock, AR 72201-1334 Entergy Arkansas Inc. #9 Entergy Court Little Rock, AR 72211 RE: Entergy comments related to Planning and Zoning items for the August 1111 Meeting Ms. James, Please find below Entergy's comments related to the items received from the Department of Planning and Development last week. The request letter said to have the comments back to you by July 18", 2016. Sienna Lake Subdiv —Block 6 —Sienna Lk Dr across from W Lake Ln: S-1424-G Entergy does not object to this proposal. An underground power line exists on the south side of Sienna Lake Road in front of this proposed development. Contact Entergy in advance to discuss future service requirements, new facilities locations and adjustments to existing facilities (if any) as this project proceeds. • Better Lawns and Gardens — 17605 Crystal Valley Rd.: Z-5511-G Entergy does not object to this proposal. A single phase power line exists on the west side Crystal Valley Rd. in front of this development and power appears to already be extended to a few of the structures on the property. Caution should be used if moving large equipment, structures, or materials underneath the overhead lines located along the road. Contact Entergy in advance to discuss future service requirements, new facilities locations and adjustments to existing facilities (if any) as this project proceeds. • Lots 1 and 2 Miles Addition —16604 Pride Valley Rd: S-1778 Entergy does not object to this proposal. A single phase power line exists along Pride Valley Road in the vicinity of this proposed lot. There do not appear to be any existing conflicts with Entergy facilities on this property. Contact Entergy in advance to discuss future service requirements, new facilities locations and adjustments to existing facilities (if any) as this project proceeds. Longleaf Cove Lot 24 — 2 Longleaf Cove: Z-8233-B Entergy does not object to this proposal. Caution should be used during the construction of this porch as an overhead power line exists to the east of this property along Katillus Road within the vicinity of this house. However, there do not appear to be any existing conflicts with Entergy facilities on this property. Contact Entergy in advance to discuss adjustments to existing facilities (if any) as this project proceeds. • 1511 and Park Lane —15" and Park Ln — 515-519 E 15th St.: Z-9149 Entergy does not object to this proposal. Service is already being provided to the existing structures at the rear of the property. Caution should be used in constructing or utilizing parking pads in the rear of these houses when near electrical power lines or poles. Contact Entergy regarding facilities locations or adjustments to existing facilities (if any) if deemed necessary. The Parks Subdivision - So. Side of Mann Rd in 9600-9700 Block: S-1777 Entergy Distribution does not object to this proposal. A three phase power line exists along the south side of Mann Road which can be utilized to provide power to this development. However, the project proposes to utilize Entergy Transmission line easements for pedestrian walking trails and a few lots appear to encroach onto the Transmission easements. Contact Entergy Transmission well in advance to discuss the future use of its easements and contact Entergy Distribution well in advance to discuss future service requirements, new Distribution facilities locations and adjustments to existing Distribution facilities (if any) as this project proceeds. • Lot I W. Markham Parkway Addition — 13401 Chenal Parkway: Z-5178-D Entergy does not object to this proposal. Service is already being provided to this structure. Contact Entergy in advance to discuss adjustments to existing facilities (if any) as this project proceeds. ■ Lot 16 Chambers Addition —18 Sheila Lane: S-1064-C Entergy does not object to this proposal. A single phase underground electrical line runs along the north side of Sheila Lane. There do not appear to be any existing conflicts with Entergy facilities on this property. Contact Entergy in advance to discuss future service requirements, new facilities locations and adjustments to existing facilities (if any) as this project proceeds. • 510-524 Main Street — 510-524 So. Main St.: Z-8872-A Entergy does not object to this proposal and has already been working with the developer. Service is being provided to the building via an on -site vault which provides power to the entire building. Contact Entergy should service requirements or loads differ significantly than what was originally requested. ■ Stone Crest Apartments — 9700 Baseline Rd.: Z-9105 Entergy does not object to this proposal. A three phase electrical line runs along the north side of Baseline Road in front of this property and a line also exists through the property. Extreme caution must be used in the construction activities in the vicinity of the power lines so that proper clearances are maintained. Electrical service may need to be reworked as the project continues. Contact Entergy in advance regarding future service requirements to the development, desired line extensions, and future facilities locations as this project proceeds. East Village —1200 thru 1400 Blocks of E. 61' St.: Z-9150 Entergy does not object to this proposal. However, power lines exist along 6th Street, Shall Street, and Thomas Street with multiple crossings and potential conflicts with the development and landscaping. Extreme caution must be used in the construction activities in the vicinity of the power lines so that proper clearances are maintained. Contact Entergy in advance to discuss future service requirements, new facilities locations and adjustments to existing facilities (if any) as this project proceeds. Shackleford Warehouse #1 — South of & adjacent to 5310 Shackleford Rd.: Z-8009-C Entergy does not object to this proposal. A three phase power line exists along the west side of Shackleford Road on the east side of the property. There do not appear to be any conflicts with existing Entergy facilities. Contact Entergy in advance regarding future service requirements to the development and future facilities locations as this project proceeds. • Porter Short form — SE corner of Hwy. 10 and Ferndale Cutoff Rd.: Z-9151 Entergy does not object to this proposal. Service is already being provided to this structure. Contact Entergy in advance to discuss adjustments to existing facilities (if any) as this project proceeds. Lot 4, the Village at Colonel Glenn — North of David O. Dodd in 13700 Blk.: Z-6973-G Entergy does not object to this proposal. Three phase power lines exist along Lawson Road to the west and along David O. Dodd to the east of the property. There do not appear to be any conflicts with existing Entergy facilities. Contact Entergy in advance regarding future service requirements to the development and future facilities locations as this project proceeds. Mountain Valley — 25616 Highway 10: S-1776 Entergy does not object to this proposal. A three phase power line exists along the north side of Highway 10 on the south side of the property. There do not appear to be any conflicts with existing Entergy facilities. Contact Entergy in advance regarding future service requirements to the development and future facilities locations as this project proceeds. If you need further assistance you may call me at 501-954-5158 or e-mail me at bneumei@entergy.com. Sincerely, Bernard Neumeier Region Engineering Supervisor Entergy Arkansas, Inc. Z-5178-A Address: 13401 Chenal Parkway Planning Division: This request is located in Ellis Mountain Planning District. The Land Use Plan shows Neighborhood Commercial (NC) for this property. The Neighborhood Commercial category includes limited small-scale commercial development in close proximity to a neighborhood, providing goods and services to that neighborhood market area. The applicant has applied for a revision of PCD (Planned Commercial District) to allow the use of a previously approved wellness center by one doctor's patients to a wellness center open for membership to the general public. The request is within the Chenal Design Overlay District. Master Street Plan: To the south of the property is Chenal Parkway and it is a Principal Arterial, east of the property is Old Town Road and it is a Local Street on the Master Street Plan. A Principal Arterial is to serve through traffic and to connect major traffic generators or activity centers within the urbanized area. Entrances and exits should be limited to minimize negative effects of traffic and pedestrians on Chenal Parkway since it is a Principal Arterial. The primary function of Local Streets is to provide access to adjacent properties. Local Streets that are abutted by non-residential zoning/use or more intensive zoning than duplexes are considered as "Commercial Streets". A Collector design standard is used for Commercial Streets. These streets may require dedication of right-of-way and may require street improvements for entrances and exits to the site. Bicycle Plan: There are no bike routes shown in the immediate vicinity. Z-5511-G Address: 17605 Crystal Valley Road Planning Division: This request is located in Crystal Valley Planning District. The Land Use Plan shows Mixed Use (MX) for this property. The Mixed Use category provides for a mixture of residential, office and commercial uses to occur. A Planned Zoning District is required if the use is entirely office or commercial or if the use is a mixture of the three. The applicant has applied for a revision of PCD (Planned Commercial District) to allow a landscape company to use the property as office and to store equipment. Master Street Plan: To the west of the property is Crystal Valley Road and it is a Principal Arterial on the Master Street Plan. A Principal Arterial is to serve through traffic and to connect major traffic generators or activity centers within the urbanized area. Entrances and exits should be limited to minimize negative effects of traffic and pedestrians on Crystal Valley Road since it is a Principal Arterial. Bic cle Plan: There is a Class I Bike Path shown along Crystal Valley Road. A Bike Path is to be a paved path physically separate for the use of bicycles. Additional right-of-way or/and easement is recommended. Nine -foot paths are recommended to allow for pedestrian use as well (replacing the sidewalk). Z-6973-G Address: North of David O Dodd Road in 13700 Block Planning Division. This request is located in 65th Street West Planning District. The Land Use Plan shows Mixed Office and Commercial (MOC) for this property. This category provides for a mixture of office and commercial uses to occur. Acceptable uses are office or mixed office and commercial. A Planned Zoning District is required if the use is mixed office and commercial. The applicant has applied for a rezoning from 0-3 (General Office District) to PCD (Planned Commercial District) to allow the development of this lot with automobile sales related activities including a sales office and parking for new and used inventory. Master Street Plan: To the south of the property is David O Dodd Road and it is a Minor Arterial, to the north-west of the property is Lawson Road and it is a Local Street on the Master Street Plan. A Minor Arterial provides connections to and through an urban area and their primary function is to provide short distance travel within the urbanized area. The primary function of Local Streets is to provide access to adjacent properties. Local Streets that are abutted by non-residential zoning/use or more intensive zoning than duplexes are considered as "Commercial Streets". A Collector design standard is used for Commercial Streets. These streets may require dedication of right-of-way and may require street improvements for entrances and exits to the site. Bicycle Plan: A Class II Bike Lanes are shown along David O Dodd Road. These Bike Lanes provide a portion of the pavement for the sole use of bicycles. Z-8105-B Address: 112 South University Avenue Planning Division: This request is located in West Little Rock Planning District. The Land Use Plan shows Mixed Use (MX) for this property. Mixed Use category provides for a mixture of residential, office and commercial uses to occur. A Planned Zoning District is required if the use is entirely office or commercial or if the use is a mixture of the three. A Planned Zoning District is required if the use is mixed office and commercial. The applicant has applied for a revision of a PCD (Planned Commercial District) to allow the placement of a 3rd sign on the south fagade of the building. This request is within the Midtown Design Overlay District. Master Street Plan: To the east of the property is South University Avenue and it is a Principal Arterial on the Master Street Plan. A Principal Arterial is to serve through traffic and to connect major traffic generators or activity centers within the urbanized area. Entrances and exits should be limited to minimize negative effects of traffic and pedestrians on South University. This street may require dedication of right-of-way and may require street improvements for entrances and exits to the site. Bicycle Plan: There are no bike routes shown in the immediate vicinity. Z-8233-B Address: 2 Longleaf Cove Planning Division- This request is located in Chenal Planning District. The Land Use Plan shows Residential Low Density (RL) for this property. Residential Low category provides for single family homes at densities not to exceed 6 dwelling units per acre. Such residential development is typically characterized by conventional single family homes, but may also include patio or garden homes and cluster homes, provided that the density remain less than 6 units per acre. The applicant has applied for a revision of a PD-R (Planned District Residential) to allow a covered porch within the rear setback. Master Street Plan: To the east of the property is South Katillus Road, to the south of the property is Longleaf Cove and they are both Local Streets on the Master Street Plan. The primary function of Local Streets is to provide access to adjacent properties. Local Streets that are abutted by non-residential zoning/use or more intensive zoning than duplexes are considered as "Commercial Streets". A Collector design standard is used for Commercial ' Streets. These streets may require dedication of right-of-way and may require street improvements for entrances and exits to the site. Bicycle Plan: There is a Class III Bike Route shown on Katillus Road. This bike route requires no additional right-of-way, but either a sign or pavement marking to identify and direct the route. Z-8872-B Address: 510-524 Main Street Planning Division: This request is located in Downtown Planning District. The Land Use Plan shows Mixed Use Urban (MXU) for this property. Mixed Use Urban provides for a mix of residential, office and commercial uses not only in the same block but also within the same structure. This category is intended for older "urban" areas to allow dissimilar uses to exist, which support each other to create a vital area. Development should reinforce the urban fabric cresting a 24-hour activity area. Using the Planned Zoning District or the Urban Use District, high and moderate density developments that result in a vital (dense) pedestrian oriented area are appropriate. The applicant has applied for a revision to a previously approved PCD (Planned Commercial Development) for the MM Cohn Building, adding the Arkansas Annex Building and the Arkansas Building to PCD to allow the use of the three (3) existing buildings for mixed uses including office, retail and residential uses. Master Street Plan: To the east of the property is Main Street and it is a Minor Arterial, to the south of the property is West 6th Street and it is Collector, to the north of the property is West Capitol and it is a Local Street on the Master Street Plan. A Minor Arterial provides connections to and through an urban area and their primary function is to provide short distance travel within the urbanized area. Entrances and exits should be limited to minimize negative effects of traffic and pedestrians on Main Street. The primary function of a Collector Road is to provide a connection from Local Streets to Arterials. The primary function of Local Streets is to provide access to adjacent properties. Local Streets that are abutted by non- residential zoning/use or more intensive zoning than duplexes are considered as "Commercial Streets". A Collector design standard is used for Commercial Streets. These streets may require dedication of right-of-way and may require street improvements for entrances and exits to the site. Bicycle Plan: There is a Class III Bike Route shown on Main Street. This bike route requires no additional right-of-way, but either a sign or pavement marking to identify and direct the route. Z-9105-A Address: 9700 Baseline Road Planning Division: This request is located in Geyer Springs West Planning District. The Land Use Plan shows Suburban Office (SO) for this property. The suburban office category shall provide for low intensity development of office or office parks in close proximity to lower density residential areas to assure compatibility. A Planned Zoning District is required. The applicant has applied for a rezoning from R-2 to PRD (Planned Residential Development) for reuse of existing buildings and paving of new parking. Master Street Plan: To the south of the property is Baseline Road and it is a Principal Arterial, to the east of the property is Winston Drive and it is a Local Street on the Master Street Plan. A Principal Arterial is to serve through traffic and to connect major traffic generators or activity centers within the urbanized area. Entrances and exits should be limited to minimize negative effects of traffic and pedestrians on Baseline Road since it is a Principal Arterial. The primary function of Local Streets is to provide access to adjacent properties. Local Streets that are abutted by non-residential zoning/use or more intensive zoning than duplexes are considered as "Commercial Streets". A Collector design standard is used for Commercial Streets. These streets may require dedication of right-of-way and may require street improvements for entrances and exits to the site. Bicycle Plan: A Class II Bike Lanes are shown along Baseline Road. This Bike Lane provides a portion of the pavement for the sole use of bicycles. Z-9149-A Address: 515-519 15th Street Planning Division: This request is located in Central City Planning District. The Land Use Plan shows Residential Low Density (RL) for this property. Residential Low category provides for single family homes at densities not to exceed 6 dwelling units per acre. Such residential development is typically characterized by conventional single family homes, but may also include patio or garden homes and cluster homes, provided that the density remain less than 6 units per acre. The applicant has applied for a rezoning from R-4 to PD-R (Planned District Residential) for replat of existing residential lots. Master Street Plan: To the north of the property is E 15th Street, to the east of the property is Park Lane and they are both Local Streets on the Master Street Plan. The primary function of Local Streets is to provide access to adjacent properties. Local Streets that are abutted by non-residential zoning/use or more intensive zoning than duplexes are considered as "Commercial Streets". A Collector design standard is used for Commercial Streets. These streets may require dedication of right-of-way and may require street improvements for entrances and exits to the site. Bicycle Plan: There are no bike routes shown in the immediate vicinity. Z-9150-A Address: 1200 through 1400 Blocks of East 6th Street Planning Division: This request is located in 1-30 Planning District. The Land Use Plan shows Mixed Use Urban (MXU) and Industrial (1) for this properties. Mixed Use Urban category provides for a mix of residential, office and commercial uses not only in the same block but also within the same structure. This category is intended for older "urban" areas to allow dissimilar uses to exist, which support each other to create a vital area. Development should reinforce the urban fabric cresting a 24-hour activity area. Using the Planned Zoning District or the Urban Use District, high and moderate density developments that result in a vital (dense) pedestrian oriented area are appropriate. The industrial category encompasses a wide variety of manufacturing, warehousing research and development, processing, and industry related office and service activities. Industrial development typically occurs on an individual tract basis rather than according to an overall development plan. The applicant has applied to rezone five (5) parcels around the intersection of 6th Street, East 6th Street and Shall Avenue from UU (Urban Use District) and 1-3 (Heavy Industrial District) to PCD (Planned Commercial Development) to allow the redevelopment of the area with'a mixed use development including residential, office and commercial uses. This request is within the Presidential Park Overlay District. Master Street Plan: The five (5) parcels are around the intersection of 6th Street and Shall Avenue which are shown as Locals Streets on the Master Street Plan. The primary function of Local Streets is to provide access to adjacent properties. Local Streets that are abutted by non-residential zoning/use or more intensive zoning than duplexes are considered as "Commercial Streets". A Collector design standard is used for Commercial Streets. These streets may require dedication of right-of-way and may require street improvements for entrances and exits to the site. Bicycle Plan: There is a Class III Bike Route shown on East 61h Street and Shall Avenue. These bike routes require no additional right-of-way, but either a sign or pavement marking to identify and direct the route. Z-9151 Address: Southeast Corner of Highway 10 and Ferndale Cutoff Road PlanningDivision: This request is located in Chenal Planning District. The Land Use Plan shows Commercial (C) and Park/Open Space (PK/OS) for this property. The Commercial category includes a broad range of retail and wholesale sales of products, personal and professional services, and general business activities. Commercial activities vary in type and scale, depending on the trade area that they serve. Park/Open Space category includes all public parks, recreation facilities, greenbelts, flood plains, and other designated open space and recreational land. The applicant has applied for a rezoning from an existing non -conforming R-2 (Single Family) use to PCD (Planned Commercial Development) to allow the site with C-3 (General Commercial District) uses as well as limited outdoor display as the existing playground equipment materials associated with a plant nursery. The request is within the Highway 10 Overlay District. Master Street Plan: To the north-east of the property is Highway 10, to the west of the property is Ferndale Cutoff Road and they are both shown as Principal Arterials on the Master Street Plan. A Principal Arterial is to serve through traffic and to connect major traffic generators or activity centers within the urbanized area. Entrances and exits should be limited to minimize negative effects of traffic and pedestrians on Highway 10 and Ferndale Cutoff Roads since they are Principal Arterials. These streets may require dedication of right-of-way and may require street improvements for entrances and exits to the site. Bicycle Plan: There is a Class I Bike Path shown along Highway 10. A Bike Path is to be a paved path physically separate for the use of bicycles. A Class 11 Bike Lanes are shown along Ferndale Cutoff Road. This Bike Lane provides a portion of the pavement for the sole use of bicycles. Rock Region �V,A METRO Rock Region METRO Planning and Subdivision Review Memo To: City of Little Rock Planning and Development, Donna James, Monte Moore, Dana Carney From: Kathleen Lambert, Sr. Transit Planner Date: July 18, 2oi6 Re: Subdivision Reviews Julyzo, 2016 hearing 1) Z-5991.-E Tract 3. the Villages of Wellington PCD a) Location is not currently served by METRO but is part of our long range plan. Because it is a senior residence facility the canopy and driveway must be design to accommodate paratransit vehicle services. This includes accessibility curb ramps, canopy height which will allow the loading of passengers at the front doors and proper curb radii for larger vehicles. z) S-1424-G Sienna Lake Subdivision Block 6 preliminary plat (single family development) a) Location is not currently served by METRO but is part of our long range plan. Include appropriate pedestrian infrastructure for future access to transit routes. 3) Z-5511-G 1.7605 Crystal Valley Road- PCD a) Location is not currently served by METRO. We have no comments regarding this PCD. 4) S-1778 3.6604 Pride Valley Road- single family lot plat a) Location is not currently served by METRO. We have no comments regarding this plat. 5) Z-8233-B z Long Leaf Cove- single family a) Location is served nearby by METRO on Route 25 Pinnacle Mtn. We have no comments regarding this plat. 6) Z-9149 15th St and Park Lane- PD-R a) Location served nearby by METRO route 6 Granit Mtn. Provide pedestrian infrastructure for access to the transit route. 7) S-1777 The Parks Subdivision Preliminary plat a) Location is currently served by METRO on routes 17 and 22. The development of this neighborhood street grid is important for residents to have access to the transit and paratransit services. Dead-end "lollipop" streets and disconnected sidewalk networks will impede resident's access to transit. We recommend along with the neighborhood exits on Mann Road that Peace Valley Road be improved and provided as an access exit out of the neighborhood. This will connect the transit route and provide efficient routing for paratransit services. 8) Z-5178-D 1.3401 Chenal Parkway a) Location is not currently served by METRO but is part of our long range plan. The pedestrian infrastructure should be continuous and improved for access to the future West little Rock express route. 9) S-1o64-C 18 Sheila Lane Lot 16 Chambers Addition a) Location is not currently served by METRO. We have no comments regarding this PCD. 10) Z-8872-A 510-524 Main Street revised- PCD a) Location is served by METRO by several routes and is in the heart of the system in downtown Little Rock. The proposed planters are numerous and block access to the cross walk and bus stops because they are located so close to the corner. We request that planters located along the sidewalk be clear 60' away from the corner radius on 6th and Main Streets to allow free pedestrian movements near traffic control signals and transit stop access. 11) Z-9105 970o Baseline Road Stone Crest Apartments a) Location is currently served by METRO on route 23. Asa property on along the transit route sidewalk infrastructure is import for access to the route. The plan as shown does not include pedestrian infrastructure. We recommend the addition of these important amenities. 12) Z-9150 1200-140o Blocks of 61h St- Planned Commercial Development Mixed Use a) Locations along 61h Street are currently served by METRO on the Presidential Center - East 6th Street Route 1z. Our current annual service changes include add service to this corridor to support expected development and employment opportunities along East 6th St. The roadway redesign as shown will not dimensionally allow for bus service along Shall St and 6th Street where the route will continue to run. The street corner radii need to beat least 25'-0" for the bus to turn. The parking spaces are too close to the intersection to allow us to position bus stops. While the "bulbed- out" crossings are helpful however they are too short to serve as a bus stop. METRO requests a meeting with relevant departments and the developer in order to discuss our concerns and make this street design truly multi -modal. 13) Z-8009-C Shackleford Warehouse #1 Zoning Site Plan a) Location is not currently served by METRO. We have no comments regarding this PID. 14) Z-9151 Porter Short form PCD Hwy 10 and Ferndale Cut-off a) Location is not currently served by METRO. We have no comments regarding this PCD. 15) Z-6973-G Lot 4 the Village at Col Glen & David O. Dodd Road, car dealer PCD a) Location is not currently served by METRO but is part of our long range plan. Provide pedestrian infrastructure for access to employment and future transit route. 16) S-1776 Mountain Valley preliminary Plat- PRD a) Location is not currently served by METRO but is part of our long range plan. As part of our future service we request the developer review the street plan to remove any dead- end situations which prevent access for efficient paratransit service. We also recommend a review and coordinated design with Hwy 10 and Pleasant Grove Road. Future development, signalized intersections and multi -modal transportation design will benefit from coordinated planning in this area. MEMORANDUM TO: DONNA JAMES, SUBDIVISION ADMINISTRATOR FROM: TRACY SPILLMAN, PLANS DEVELOPMENT ADMINISTRATOR SUBJECT: REVIEW OF THE BUFFER AND LANDSCAPE REQUIREMENTS OF THE JULY 20, 2016, SUBDIVISION COMMITTEE MEETING CC: DANA CARNEY, ZONING & SUBDIVISION MANAGER DATE: JULY 15, 2016 1. 18 Shelia Lane _ (S-1064-C) No Comment 2. Sienna Lake Drive across from West Lake Lane S-1424-G 3. 25616 Hi hwa 10 S-1776 No Comment 4. South side of Mann Road in the 9600 -9700 block S-1777 No Comment 5. 16604 Pride Valley Road SS�177_8) No Comment 6. 13401 Chenal Parkway (Z-5178-D Site plan must comply with the City's minimal landscape and buffer ordinance requirements and the Chenal Overlay District. Parking areas must be designed and paved to meet the requirements of the city codes and ordinances. The City Beautiful Commission recommends preserving as many existing trees as feasible on this site. Credit toward fulfilling Landscape Ordinance requirements can be given when preserving trees of six (6) inch caliper or larger. 7. 17605 CEystal Valley Road Z-5511-G Any new site development must comply with the City's minimal landscape and buffer ordinance requirements. A land use buffer six (6) percent of the average width / depth of the lot will be required when an adjacent property has a dissimilar use of a more restrictive nature. The adjacent properties to the south and east are zoned R-2. As a component of all land use buffer requirements, opaque screening, whether a fence or other device, a minimum of six (6) feet in height shall be required upon the property line side of the buffer. The plantings, existing and purposed, shall be provided within the landscape ordinance of the city, section 15-102. The City Beautiful Commission recommends preserving as many existing trees as feasible on this site. Credit toward fulfilling Landscape Ordinance requirements can be given when preserving trees of six (6) inch caliper or larger. 9. David Q Dodd Road 13700 Block (Z-6973-G) Site plan must comply with the City's minimal landscape and buffer ordinance requirements. Street buffers will be required at six (6) percent of the average depth of the lot. The minimum dimension shall be one-half (`/z) the full width requirement but in no case less than nine (9) feet. The maximum dimension required shall be fifty (50) feet. Screening requirements will need to be met for the vehicular use areas adjacent to street right-of-ways. Provide screening shrubs with an average linear spacing of not less at three (3) feet within the required landscape area. Provide trees with an average linear spacing of not less than thirty (30) feet. A perimeter planting strip is required along any side of a vehicular use area that abuts adjoining property or the right-of-way of any street. This strip shall be at least nine (9) feet wide. One (1) tree and three (3) shrubs or vines shall be planted for every thirty (30) linear feet of perimeter planting strip. Eight percent (8%) of the vehicular use area must be designated for green space; this green space needs to be evenly distributed throughout the parking area(s). For developments with more than one hundred fifty (150) parking spaces the minimum size of an interior landscape area shall be three hundred (300) square feet. Interior islands must be a minimum of seven and one half (7 1 /2) feet in width. Trees shall be included in the interior landscape areas at the rate of one (1) tree for every twelve (12) parking spaces. Building landscape areas shall be provided between the vehicular use area used for public parking and the general vicinity of the building. These shall be provided at the rate equivalent to planter strip three (3) feet wide along the vehicular use area. One (1) tree and four (4) shrubs shall be planted in the building landscape areas for each forty (40) linear feet of vehicular use area abutting the building A land use buffer six (6) percent of the average width / depth of the lot will be required when an adjacent property has a dissimilar use of a more restrictive nature. The minimum dimension shall be nine (9) feet. As a component of all land use buffer requirements, opaque screening, whether a fence or other device, a minimum of six (6) feet in height shall be required upon the property line side of the buffer. The plantings, existing and purposed, shall be provided within the landscape ordinance of the city, section 15-81. The adjacent property fronting Lawson Road is zoned R-2, screening will be required. An automatic irrigation system to water landscaped areas shall be required for developments of one (1) acre or larger. The development of two (2) acres or more requires the landscape plan to be stamped with the seal of a Registered Landscape Architect. The City Beautiful Commission recommends preserving as many existing trees as feasible on this site. Credit toward fulfilling Landscape Ordinance requirements can be given when preserving trees of six (6) inch caliper or larger. 11. Adjacent to 5310 Shackleford (Z-8009-B) Site plan must comply with the City's minimal landscape and buffer ordinance requirements. Street buffers will be required at six (6) percent of the average depth of the lot. The minimum dimension shall be one-half ('/z) the full width requirement but in no case less than nine (9) feet. The maximum dimension required shall be fifty (50) feet. The average depth of the lot is four hundred and thirty-seven (437) feet. A minimum twenty-six (26) foot street buffer is required adjacent to the Shackelford and Clearwater right-of-ways. The buffer adjacent to Clearwater Drive is deficient. A perimeter planting strip is required along any side of a vehicular use area that abuts adjoining property or the right-of-way of any street. One (1) tree and three (3) shrubs or vines shall be planted for every thirty (30) linear feet of perimeter planting strip. Screening requirements will need to be met for the vehicular use areas adjacent to street right-of-ways. Provide screening shrubs with an average linear spacing of not less at three (3) feet within the required landscape area. Provide trees with an average linear spacing of not less than thirty (30) feet. Existing trees and dense understory vegetation can be retained to satisfy this requirement. An irrigation system shall be required for developments of one (1) acre or larger. The development of two (2) acres or more requires the landscape plan to be stamped with the seal of a Registered Landscape Architect. The City Beautiful Commission recommends preserving as many existing trees as feasible on this site. Credit toward fulfilling Landscape Ordinance requirements can be given when preserving trees of six (6) inch caliper or larger. 10. 2 Longleaf Cove Z-8233-B No Comment 12. 510 — 524 South Main Street (Z-8872-A Site plan must comply with the City's minimal landscape and buffer ordinance requirements and the Urban Use District. Any exiting landscape or irrigation disturbed by construction shall be repaired or replaced before completion and final acceptance of the project. The City Beautiful Commission recommends preserving as many existing trees as feasible on this site. Credit toward fulfilling Landscape Ordinance requirements can be given when preserving trees of six (6) inch caliper or larger. 13. 9700 Baseline Z-9105 Any new site development must comply with the City's minimal landscape and buffer ordinance requirements. New parking areas must meet the following requirement. Eight percent (8%) of the vehicular use area must be designated for green space; this green space needs to be evenly distributed throughout the parking area(s). The minimum size of an interior landscape area shall be one hundred fifty (150) square feet for developments with one hundred fifty (150) or fewer parking spaces. Interior islands must be a minimum of seven and one half (7 1 /2) feet in width. Trees shall be included in the interior landscape areas at the rate of one (1) tree for every twelve (12) parking spaces. The City Beautiful Commission recommends preserving as many existing trees as feasible on this site. Credit toward fulfilling Landscape Ordinance requirements can be given when preserving trees of six (6) inch caliper or larger. 14. I 5th and Park Lane 515 — 519 East 15th Street Z-9149 No Comment 15. 1200 throw h 1400 Blocks of E 6th Z-9150 Site plan must comply with the City's minimal landscape and buffer ordinance requirements and the Presidential Park Overlay District. Street buffers will be required at six (6) percent of the average depth of the lot. The minimum dimension shall be one-half (`/z) the full width requirement but in no case less than nine (9) feet. The maximum dimension required shall be fifty (50) feet. The property is located in the City's designated mature area. A twenty-five (25%) percent reduction of the perimeter width requirements is acceptable. Screening requirements will need to be met for the vehicular use areas adjacent to street right-of-ways. Provide screening shrubs with an average linear spacing of not less at three (3) feet within the required landscape area. Provide trees with an average linear spacing of not less than thirty (30) feet. Building landscape areas shall be provided at the rate equivalent to planter strip three (3) feet wide along the vehicular use area. One (1) tree and four (4) shrubs shall be planted in the building landscape areas for each forty (40) linear feet of vehicular use area abutting the building. A perimeter planting strip is required along any side of a vehicular use area that abuts adjoining property or the right-of-way of any street. This strip shall be at least nine (9) feet wide. One (1) tree and three (3) shrubs or vines shall be planted for every thirty (30) linear feet of perimeter planting strip. The property is located in the City's designated mature area. A twenty-five (25%) percent reduction of the perimeter width requirements is acceptable. Eight percent (8%) of the vehicular use area must be designated for green space; this green space needs to be evenly distributed throughout the parking area(s). For developments with more than one hundred fifty (150) parking spaces the minimum size of an interior landscape area shall be three hundred (300) square feet. Interior islands must be a minimum of seven and one half (7 1/2) feet in width. Trees shall be included in the interior landscape areas at the rate of one (1) tree for every twelve (12) parking spaces. The property is located in the City's designated mature area. A 25% reduction of the interior parking requirements is acceptable. An irrigation system shall be required for developments of one (1) acre or larger. The development of two (2) acres or more requires the landscape plan to be stamped with the seal of a Registered Landscape Architect. The City Beautiful Commission recommends preserving as many existing trees as feasible on this site. Credit toward fulfilling Landscape Ordinance requirements can be given when preserving trees of six (6) inch caliper or larger. 16. Highway 10 and Ferndale Cutoff (Z-9151) No comment. 8. 700 Wellington Hills Road Z-5991-E Site plan must comply with the City's minimal landscape and buffer ordinance requirements. Street buffers will be required at six (6) percent of the average depth of the lot. The minimum dimension shall be one-half (`/z) the full width requirement but in no case less than nine (9) feet. The maximum dimension required shall be fifty (50) feet. Trees and shrubs are required adjacent to street right-of-way. Plant material is to be provided at 1 tree and 3 shrubs for every 30 linear feet. Existing trees and vegetation can be used to satisfy landscape requirements. Screening requirements will need to be met for the vehicular use areas adjacent to street right-of-ways. Provide screening shrubs with an average linear spacing of not less at three (3) feet within the required landscape area. Provide trees with an average linear spacing of not less than thirty (30) feet. A perimeter planting strip is required along any side of a vehicular use area that abuts adjoining property or the right-of-way of any street. This strip shall be at least nine (9) feet wide. One (1) tree and three (3) shrubs or vines shall be planted for every thirty (30) linear feet of perimeter planting strip. The shared dive at the south of the property must be placed on the property line or the above perimeter requirements will need to be met. Eight percent (8%) of the vehicular use area must be designated for green space; this green space needs to be evenly distributed throughout the parking area(s). The minimum size of an interior landscape area shall be one hundred fifty (150) square feet for developments with one hundred fifty (150) or fewer parking spaces. Interior islands must be a minimum of seven and one half (7 1/2) feet in width. Trees shall be included in the interior landscape areas at the rate of one (1) tree for every twelve (12) parking spaces. Building landscape areas shall be provided between the vehicular use area used for public parking and the general vicinity of the building. These shall be provided at the fate equivalent to planter strip three (3) feet wide along the vehicular use area. One (1) tree and four (4) shrubs shall be planted in the building landscape areas for each forty (40) linear feet of vehicular use area abutting the building. An automatic irrigation system to water landscaped areas shall be required for developments of one (1) acre or larger. The City Beautiful Commission recommends preserving as many existing trees as feasible on this site. Credit toward fulfilling Landscape Ordinance requirements can be given when preserving trees of six (6) inch caliper or larger. To: Dana Carney, Zoning & Subdivision Manager Date: 7-17-16 Donna James, Zoning Monte Moore, Subdivision From: Curtis Richey / Mark Alderfer: Building Codes Building Code Comments: Z-5991-E 700 Wellington Hills Road Project is subject to full commercial plan review and approval prior to issuance of a building permit. For information on submittal requirements and the review process, contact a commercial plans examiner: Awning must comply with 13'6' clearance requirement. Curtis Richey at 501.371.4724; crichey _ littlerock.or Mark Alderfer at 501.371.4875; m a Iderferft little rock.or . 5-1424-G Sienna Lake ❑ No Comment Z-5511-G 17605 Crustal Valley Road Project is subject to full commercial plan review and approval prior to issuance of a building permit. For information on submittal requirements and the review process, contact a commercial plans examiner: Curtis Richey at 501.371.4724; cricheyplittlerock.orp, or Mark Alderfer at 501.371.4875; malderfer@littlerock.grg. 5-1789 16604 Pride Valle NC Z-9149 15th & Park NC 5-1777 Mann Road 9600-9700 Black NC S-1064-C 18 Sheila NC Z-8872-A 510-524 South Main Street Project is subject to full commercial plan review and approval prior to issuance of a building permit. For information on submittal requirements and the review process, contact a commercial plans examiner: Curtis Richey at 501.371.4724; cricheyCrDlittlerock.or or Mark Alderfer at 501.371.4875; malderfer littlerock.or . Z-9105-A 9700 Baseline Project is subject to full commercial plan review and approval prior to issuance of a building permit. For information on submittal requirements and the review process, contact a commercial plans examiner: Curtis Richey at 501.371.4724; crichey@littlerock.ora or Mark Alderfer at 501.371,4875; maiderfer@littlerock.org. Z-9180 1200-1400 Blocks of East 6th Street Project is subject to full commercial plan review and approval prior to issuance of a building permit. For information on submittal requirements and the review process, contact a commercial plans examiner: Curtis Richey at 501.371.4724; crichev@littlerock.org or Mark Alderfer at 501.371.4875; malderfer@littlerock.or. Z-8009-C South/Adjacent to 5310 Shatkleford Project is subject to full commercial plan review and approval prior to issuance of a building permit. For information on submittal requirements and the review process, contact a commercial plans examiner: Curtis Richey at 501.371,4724; cricheyWittlerock.orp,or Mark Alderfer at 501.371.4875; malderfer@littlerock.org. Z-9151 SE Corner of Hwy 10 & Ferndale Cutoff NC 5-1776 25616 Hwy 10 NC Z-6973-G North of David O Dodd in 13700 Block Project is subject to full commercial plan review and approval prior to issuance of a building permit. For information on submittal requirements and the review process, contact a commercial plans examiner: Curtis Richey at 501.371.4724; crichey@littlerock.org or Mark Alderfer at 501.371.4875; malderfer@littlerock.org. Regards, Curtis Richey Commercial Plans Examiner City of Little Rock Department of Planning and Development Planning 723 West Markham Street Zoning and Little Rock, Arkansas 72201-1334 Subdivision Phone: (501) 371-4790 Fax: (501) 399-3435 or 371-6863 September 12, 2016 McGetrick Engineering P.O. Box 30441 Little Rock, AR 72260 Re: Z-9151 - Porter Short -form PCD, located on the southeast corner of Highway 10 and Ferndale Cutoff Road Dear Sirs - Enclosed please find a copy of an Ordinance adopted by the Board of Directors at their September 6, 2016, Public Hearing approving the above referenced development. If you have any questions concerning this ordinance, please feel free to call me at 371-6821. Sincerely, Donna James, AICP Subdivision Administrator City of Little Rock Department of Planning and Development Planning 723 West Markham Street Zoning and Little Rock, Arkansas 72201-1334 Subdivision Phone: (501) 371-4790 Fax: (501) 399-3435 or 371-6863 August 12, 2016 McGetrick Engineering P.O. Box 30441 Little Rock, AR 72260 Re: Z-9151 - Porter Short -form PCD, located on the southeast corner of Highway 10 and Ferndale Cutoff Road Dear Sirs: This is to advise you that in connection with your request concerning the above referenced file number the following action was taken by the Planning Commission at its meeting on August 11, 2016: Approved with conditions. X Recommended approval with conditions. Recommended approval as submitted. Denied your request as submitted. Deferred to the Other: Meeting. This item will be forwarded to the Little Rock Board of Directors for final action. You or your representative will need to be present at the Board of Directors meeting to address any questions which may arise. The meeting date has tentatively been set for September 6, 2016. The meeting begins at 6:00 pm and is held in the Board of Directors Chambers, 500 West Markham Street, 2"d floor. If you have any questions please do not hesitate to contact me at 371-6821. Respectfully, Donna James, AICP Subdivision Administrator Area Zoning City of Little Rock Planning & Development rt; ti wwtinrr�---�• Case: Z-9151 Location: Located on the Southeast Corner Highway 10 and Ferendale Cutoff Road Ward: N/A N PD: 19 CT:42.13 0 200 400 TRS: T2N R14W 8 Feet Land Use Plan City of Little Rock Planning & Development Case: Z-9151 Location: Located on the Southeast Corner Highway 10 and Ferendale Cutoff Road Ward: N/A N PD: 19 CT 42.13 0 200 400 TRS: T2N R14W 8 Feet J L1 V) T BUILDING OUTDOOR DISPLAY �110 4.22 Acres 183814 sq. ft S 87°20'48" E 629.16' SITE DATA SITE AREA 4.22 ACRES BUILDING AREA 3,026 SQ. FT. PROPOSED USE RECREATIONAL EQUIPMENT SALES WITH OUTDOOR DISPLAY EMPLOYEES HOURS OF OPERATION 6 M-S 7:00 AM - 6:00 PM ZONING (CURRENT) ZONING (PROPOSED) R-2 C-3 USES WITH OUTDOOR DISPLAY COVERAGE BUILDING / PAVING AREA -12% k etch City of Little Rock Planning g &Development Case No: Z-9151 Name: Porter Location: Located on the southeast corner of Highway 10 & Ferendale Cutoff Road '� • C I h' U�P r�J III IIII�IIIIIII IIIIIII II I II�II III II I III2016056062 PRESENTED: 09-07-2016 02:00:10 PM RECORDED: 09-07-2016 02:11:10 PM E In Official Records of Larry Crane Circuit/County Cleric 1 = c��-,','� ,ti ORDINANCE NO. 21,292PULASKI CO, AR FEE $20.00 t cOUNIN- 3 AN OY#D'INANCE TO APPROVE A PLANNED ZONING DEVELOPMENT 4 AND ESTABLISH A PLANNED COMMERCIAL DISTRICT TITLED 5 PORTER SHORT —FORM PCD, LOCATED ON THE SOUTHEAST 6 CORNER OF HIGHWAY 10 AND FERNDALE CUTOFF ROAD (Z-9151), 7 PULASKI COUNTY, ARKANSAS, AMENDING THE OFFICIAL ZONING 8 MAP OF THE CITY OF LITTLE ROCK, ARKANSAS; AND FOR OTHER 9 PURPOSES. 10 11 BE IT ORDAINED BY THE BOARD OF DIRECTORS OF THE CITY OF LITTLE ROCK, 12 ARKANSAS. 13 Section 1. That the zoning classification of the following described property be changed from R-2, 14 Single -Family District, to PCD, Planned Commercial Development District: 15 2-9151: A part of the SW % of the SE '/ of Section 8, Township 2 North, Range 14 16 West, Pulaski County, Arkansas described as follows: Commencing at the southwest 17 corner of said southwest quarter of the southeast quarter thence North 87112'58" 18 West along the South line thereof for 173.12 feet to a point in the center of Ferndale 19 Cutoff said point also being the point of beginning; thence along said centerline the 20 following course. thence North 03131'33" West 174.55 feet; thence North 05136'02" 21 East 85.70 feet; thence North 16159'34" East 134.45 feet; thence North 26051'10"E 22 156.34 feet to a point on the south right-of-way line of Highway 10; thence along said 23 South right-of-way line the following courses: South 45021'19" East 345.80 feet; 24 thence South 44038'41" West 30.0 feet; thence South 45021'19" East 416.04 feet to a 25 point on the south line of the southwest quarter of the southeast quarter; thence North 26 87020'48" West along said south line thereof 629.16 feet to the point of beginning 27 containing 4.22 acres, more or less. 28 Section 2. That the preliminary site development plan/plat be approved as recommended by the Little 29 Rock Planning Commission, 30 Section 3. That the change in zoning classification contemplated for Porter Short -Form PCD, located 31 on the southeast corner of Highway 10 and Ferndale Cutoff Road (Z-9151), is conditioned upon obtaining 32 final plan approval within the time specified by Chapter 36, Article VII, Section 36-454 (e) of the Code of 33 Ordinances. [Page I of 2] 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 Section 4. That this ordinance shall not take effect and be in full force until the final plan approval, Section 5. That the map referred to in Chapter 36 of the Code of Ordinances of the City of Little Rock, Arkansas, and designated district map be and is hereby amended to the extent and in the respects necessary to affect and designate the change provided for in Section 1 hereof. Section 6. Severability. In the event any title, section, paragraph, item, sentence, clause, phrase, or word of this ordinance is declared or adjudged to be invalid or unconstitutional, such declaration or adjudication shall not affect the remaining portions of the ordinance which shall remain in full force and effect as if the portion so declared or adjudged invalid or unconstitutional was not originally a part of the ordinance. Section 7. Repealer. All laws, ordinances, resolutions, or parts of the same that are inconsistent with the provisions of this ordinance are hereby repealed to the extent of such inconsistency. PASSED: September 6, 2016 APPROVED: , City Clerk Mark Stodola, Mayor LS TO LEGAL FORM: R �J Thomas M. Carpenter, City Attorbly // // [Page 2 of 21 Area Zoning City of Little Rock Planning & Development Case: Z-9151 Location: Located on the Southeast Corner Highway 10 and Ferendale Cutoff Road Ward: N/A N PD: 19 CT 42.13 c 200 400 TRS: T2N R14W 8 Feet RL RM vuO RL o RM� C THIS SITE PK/OS PK/OS w z z 0 RL IvI I p IJ u d j City I_Imits Land Use Flan City of Little Rock Planning & Development Case: Z-9161 Location: Located on the Southeast Corner Highway 10 and Ferendale Cutoff Road Ward: N/A N PD: 19 CT 42.13 0 200 400 TRS: T2N R14W 8 Feet City of Little Rock Planning & Development Case No: Z-9151 Name: Porter Location: Located on the southeast corner of Highway 10 & Ferendale Cutoff Road Issue: Short -form PCD N A OFFICE OF THE CITY MANAGER LITTLE ROCK, ARKANSAS BOARD OF DIRECTORS COMMUNICATION SEPTEMBER 6, 2016 AGENDA Subject An Ordinance establishing a Planned Zoning District titled Porter Short -form PCD, located on the southeast corner of Highway 10 and Ferndale Cutoff Road. (Z-9151) Submitted by: Department of Planning and Development SYNOPSIS FISCAL IMPACT RECOMMENDATION BACKGROUND Action Required Ordinance Resolution Approval Information Report Approved By Bruce T. Moore City Manager The request is to rezone the site from R-2, Single-family to PCD, Planned Commercial Development, to recognize the existing commercial uses located on the site and allow C-3, General Commercial District uses as allowable future uses of the site. I None. Staff recommends approval of the requested PCD zoning. The Planning Commission voted to recommend approval of the PCD zoning by a vote of 9 ayes, 0 noes and 2 absent. The property is located outside the City limits of Little Rock but within the City's Extraterritorial Planning Jurisdiction. The property has historically been used as a commercial use. The property was developed as a landscape nursery and is currently being used for outdoor display of playground equipment. The request is to rezone the property to PCD, Planned Commercial Development, to BACKGROUND CONTINUED allow the use of the site for future users as a use within the C-3, General Commercial District zoning classification and also to allow the placement of outdoor display of merchandise as has been used in the past such as landscaping plants and/or outdoor playground equipment. The Planning Commission reviewed the proposed PCD request at its August 11, 2016, meeting and there were no registered objectors present. All property owners located within 200 feet of the site along with the Nowlin Creek Neighborhood Association were notified of the public hearing. Please see the attached Planning Commission minute record and site plan for the applicant's specific development proposal and the staff analysis and recommendation. OA 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 ORDINANCE NO. AN ORDINANCE APPROVING A PLANNED ZONING DEVELOPMENT AND ESTABLISHING A PLANNED COMMERCIAL DISTRICT TITLED PORTER SHORT -FORM PCD, LOCATED ON THE SOUTHEAST CORNER OF HIGHWAY 10 AND FERNDALE CUTOFF ROAD (Z-9151), PULASKI COUNTY, ARKANSAS, AMENDING THE OFFICIAL ZONING MAP OF THE CITY OF LITTLE ROCK; AND FOR OTHER PURPOSES. BE IT ORDAINED BY THE BOARD OF DIRECTORS OF THE CITY OF LITTLE ROCK, ARKANSAS. SECTION 1. That the zoning classification of the following described property be changed from R-2, Single-family District to PCD, Planned Commercial Development District: Z( 9151) — A part of the SW '/4 of the SE '/4 of Section 8, Township 2 North, Range 14 West, Pulaski County, Arkansas described as follows: Commencing at the Southwest corner of said Southwest Quarter of the Southeast Quarter thence North 87112'58" West along the South line thereof for 173.12 feet to a point in the center of Ferndale Cutoff said point also being the point of beginning; thence along said centerline the following course: thence North 03°31'33" West 174.55 feet; thence North 05136'02" East 85.70 feet; thence North 16°59'34" East 134.45 feet; thence North 26°51' 10"E 156.34 feet to a point on the South right of way line of Highway 10; thence along said South right of way line the following courses: South 45121'19" East 345.80 feet; thence South 44138'41" West 30.0 feet; thence South 45121'19" East 416.04 feet to a point on the South line of Page 1 of 3 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 the Southwest Quarter of the Southeast Quarter; thence North 87°20'48" West along said South line thereof 629.16 feet to the point of beginning containing 4.22 acres more or less. SECTION 2. That the preliminary site development plan/plat be approved as recommended by the Little Rock Planning Commission. SECTION 3. That the change in zoning classification contemplated for Porter Short -form PCD, located on the southeast corner of Highway 10 and Ferndale Cutoff Road (Z-9151) is conditioned upon obtaining final plan approval within the time specified by Chapter 36, Article VII, Section 36-454 (e) of the Code of Ordinances. SECTION 4. That this Ordinance shall not take effect and be in full force until the final plan approval. SECTION 5. That the map referred to in Chapter 36 of the Code of Ordinances of the City of Little Rock, Arkansas, and designated district map be and is hereby amended to the extent and in the respects necessary to affect and designate the change provided for in Section 1 hereof. SECTION 6. Severability. In the event any title, section, paragraph, item, sentence, clause, phrase, or word of this ordinance is declared or adjudged to be invalid or unconstitutional, such declaration or adjudication shall not affect the remaining portions of the ordinance which shall remain in full force and effect as if the portion so declared or adjudged invalid or unconstitutional was not originally a part of the ordinance. SECTION 7. Repealer. All laws, ordinances, resolutions, or parts of the same that are inconsistent with the provisions of this ordinance are hereby repealed to the extent of such inconsistency. Page 2 of 3 I PASSED: 2 3 ATTEST: 4 5 6 7 8 9 10 11 12 13 14 15 City Clerk APPROVED AS TO FORM: City Attorney // APPROVED: Mayor Page 3 of 3 R2 THIS SITE C3 C'gME,4p R2 N',CQb:(N CUP Op Q y At —YR2 � J Area Zoning City of Little Rock Planning & Development �i• at AF z J W_ z z O 7 IUI u u City Limits Case: Z-9151 Location: Located on the Southeast Corner Highway 10 and Ferendale Cutoff Road Ward: N/A N PD: 19 CT:42.13 0 200 400 TRS: T2N R14W 8 Feet RL :7dd RM� ti / THIS SITE PK/OS c c V RL _ ® El ~c�M�RQNW � V PK/OS RL Land Use Plan City of Little Rock Planning & Development z J tLl z z O U RL 0 e i rum.. �..�a.r.r.. i City Limits Case: Z-9151 Location: Located on the Southeast Corner Highway 10 and Ferendale Cutoff Road Ward: NIA N PD: 19 CT:42.13 0 200 400 TRS: T2N R14W 8 Feet City of Little Rock Planning & Development Case No: Z-9151 Name: Porter Location: Located on the southeast corner of Highway 10 & Ferendale Cutoff Road Issue: Short -form PCD N A James, Donna From: Jim Cranor <jcranor@pulaskicounty.net> Sent: Thursday, July 14, 2016 7:52 AM To: James, Donna Cc: Van McClendon Subject: County Comments Z-5511-G, Z-9151, Donna, Below are Pulaski County's comments for the referenced items Z-5511-G Dedicate R.O.W. to meet City of Little Rock Master Street Plan. Z-9151 Dedicate R.O.W. to meet City of Little Rock Master Street Plan. Jim Cranor Plans Review Coordinator Pulaski County Planning and Development 3200 Brown Street Little Rock, AR 72204 501-340-8265 sfpzd.doc 03/01/10 INFORMATION SHEET FOR SUBDIVISION, PZD's ZONING OR SUBDIVISION SITE PEAN REVIEWS ITEM NO. DATE FILE NO. r 9 [ !� NAME:�� �� D LOCATION: DEVELOPER: % V/ !'O Af �� I 11 S7 STREET ADDRESS ¢ %�l4�/e w,4Ll CrrY/STATE/ZIP j. ¢ 37 TELEPHONE NO. ENGINEER: /�F r ie,*- STREET ADDRESS 11601 CITY/STATE/ZrP TELEPHONE NO. AREA [ FT. NEW STREET. ZONING PLANNING DISTRICT VARIANCES REQUESTED 1.) 2.) 3.) 4.) NUMBER OF LOTS PROPOSED USES C -3 Ai% CENSUS TRACT sfpzd.doc 03/01/10 APPLICATION FOR PLANNED ZONING DEVELOPMENT - SHORT FORM CASE FILE NO. Z-albl PL4NNING COMMISSION MEETING DOCKETED FOR 04y6-U%i 7,/ . d# SDI 6, at i, Oo p.m. Application is hereby made to the Board of Directors of Little Rock, Arkansas through the Planning Commission pursuant to Arkansas law on City planning, Act 186 of 1957, Acts of Arkansas, and Section 36 of the Little Rock Code of Ordinances as amended, petitioning for classification of the following described area as a Short Form Planned Zoning Development. Legal Description: �z -A6nE'�1 2�� Title to this property is vested in: 8910FK as— 7-- If an individual other than the title holder files this application, attachment of a letter is required authorizing this person to act on behalf of the title holder. It is desired that the boundaries shown on the District Map be amended and that this area be amended and that this area be reclassified from the present ►Y — District to oe a Z% District. Present Use of Property: �Z [ 4�m Al jazo Desired Use of Property ^ 7, ( 0 M flit EO � � � �G f�l S "0 � L� / -� It is understood that notice of the public hearing hereon before the Little Rock Planning Commission will be published at least fifteen (15) days prior to said hearing in a daily newspaper as required by Act 186 of the 1957 Acts of Arkansas and Section 23 of said Ordinance, and that notice of preliminary hearing before the Commission must be circulated by the applicant to all other parties in interest, including owners of land within 200 feet of the boundary of the area under consideration as required by the rules of the Commission, and that the cost of these notices shall be borne by the applicant. (OWNER) MAIL ADDRESS: or (AGENT) HOME PHONE: BUSINESS PHONE: %I FILING FEE: P.C. APPROVED: gill Collectors $ : paid stamp P.C. DENIED: Ct BD. OF DIR. APPROVED: c here ORDINAN NO.24 X Signature of Scc of Commission or Authorized Agent 8/2/2016 (835 unread) - mcgetrick2@sbcglobal.net- att.net Mail AT&T — Mail News Sports Finance Vveatne, _ntertainmen. ,obile LAHtG I V U-verse at; corn More En Espanol Q All Search Search Mail Search Web Home PAT Compose OA ♦ p Archive 0 Move ® Deli_ CcoIfspakli ♦ *6re Inbox (835) No Subject] (3 P-1. [� Drafts (19) Sent MCGETRICK MCGETRICK Chief Wheeler, I arr Jul 29 at 9:00 AM Archive WPFD FIRE DEPARTMENT <wpfd@sbcglobal.net> Jul 31 at 10:35 AM Spam (44) To MCGETRICK MCGETRICK Trash (8) CC Kirk Holt, Alan Hubbard, Joel DeWitt Smart Views I am familiar with your property, it Important Unread is across the street from our Starred Station #3. FYI, I have asked for a_ People fire hydrant to be laced across p :. Social Shopping Ferndale Cutoff from your property f� Travel if the proposed storage complex is Finance built. > Folders > Recent Chief Wheeler is rui!rc FREE SHIPPING + FREE RETURNS MCGETRICK MCGETRICK o mcgetrick2@sbcglobal.net Ci, Search Emails b PM To WPFD FIRE DEPARTMENT CC Kirk Holt, Alan Hubbard, Joel DeWitt Chief Wheeler, Thanks, I appreciate the information. Pat McGetrick > Show original message h Reply <4% Reply to All ♦ Forward ••• More Click to reply all Send W https://m g. m ai 1.yahoo.com /neoA aunch?. partner=s be&. rand= 9noi ncm vgn2s7#m ai l McGetrick & McGetrick, Inc. Civil Engineering June 30, 2016 Donna James, Subdivision Administrator City of Little Rock, Arkansas Planning and Development 723 West Markham Little Rock, AR 72201-1334 Re: PCD Porter Property Dear Ms. James: We are herewith submitting a PCD for the above referenced project. This project is located at the southeast corner of Highway 10 and Ferndale Cutoff. It is zoned R-2 and we are requesting a PCD zoning with C-3 uses and outdoor display. The owner has no desire to make any revisions in the current layout of the property. It is currently being used as a recreational equipment sales and display facility. The property will continue to be used as such. If you have any questions regarding the information provided, please feel free to contact me. Sincerely, cGetrick, Inc. )AatricMcGetrick, P.E. PM:cmc 116o1 Sass Pro Parkway Little Rock, AR 72210 501455-8899 501-455-0525 mcgetrick2@sbcgJobal.net QWNERSHIENZONE SEARCH Date: July 22, 2016 File Number: 16-007307-180 Prepared For: McGetrick Engineers Lenders Title Company has searched the records of the Circuit Clerk of Pulaski County, Arkansas to determine the apparent ownership of property within 200 feet of the perimeter of the following described property as of June 29, 2016 at 8:00 AM DEEDED PROPERTY DESCRIPTION: A PART OF THE SW1/4 OF THE SE1/4 OF SECTION 8, T2N, R14W OF THE 5thP.M. PULASKI COUNTY, ARKANSAS BEING MORE PARTICULARLY DESCRIBED AS FOLLOWS: COMMENCE AT THE SW CORNER OF SAID SW1/4 OF THE SE1/4 AND RUN EAST 144 FEET TO THE POINT OF BEGINNING; THENCE CONTINUE EAST 766.2 FEET; THENCE NORTH 48005' WEST 879.00 FEET; THENCE SOUTH 19°02' WEST 404.9 FEET; THENCE SOUTH 05034' EAST 205.5 FEET TO THE POINT OF BEGINNING AND CONTAINING 5.56 ACRES MORE OR LESS. NOTE: APPROX. 2 ACRES ARE IN THE RIGHT-OF-WAY. PROPERTY DESCRIPTION AS SURVEYED: A PART OF THE SW 1/4 OF THE SE 1/4 OF SECTION 8, TOWNSHIP 2 NORTH, RANGE 14 WEST, PULASKI COUNTY, ARKANSAS DESCRIBED AS FOLLOWS: COMMENCE AT THE SOUTHWEST CORNER OF SAID SOUTHWEST QUARTER OF THE SOUTHEAST QUARTER; THENCE NORTH 87°12'58" EAST ALONG THE SOUTH LINE THEREOF FOR 173.12 FEET TO A POINT IN THE CENTER OF FERNDALE CUTOFF SAID POINT ALSO BEING THE POINT OF BEGINNING; THENCE ALONG SAID CENTERLINE THE FOLLOWING COURSES: NORTH 03°31'33" WEST 174.55 FEET; THENCE NORTH 05036'02" EAST 85.70 FEET; THENCE NORTH 16°59'34" EAST 134.45 FEET; THENCE NORTH 26051'l0" EAST 156.34 FEET TO A POINT ON THE SOUTH RIGHT OF WAY LINE OF HIGHWAY NUMBER 10; THENCE ALONG SAID SOUTH RIGHT OF WAY LINE THE FOLLOWING COURSES: SOUTH 45°21'19" EAST 345.80 FEET; THENCE SOUTH 44°38'41" WEST 30.00 FEET; THENCE SOUTH 45021'19" EAST 416.04 FEET TO A POINT ON THE SOUTH LINE OF THE SOUTHWEST QUARTER OF THE SOUTHEAST QUARTER; THENCE NORTH 87020'48" WEST ALONG SAID SOUTH LINE THEREOF 629.16 FEET TO THE POINT OF BEGINNING, CONTAINING 4.22 ACRES, MORE OR LESS. Following is a list of apparent owners of property within 200 feet of the perimeter of the above described property as reflected by the records of the Circuit Clerk of Pulaski County, Arkansas: Part of the NW1/4 NE1/4, Section 17, Township 2 North, Range 14 West The Ford Family Limited Partnership dated i l/l/l995 22311 Highway 10 Little Rock, Arkansas 72223 LTC - Ownersldp Zone SearchAf 1 of 3 Part of the NW1/4 NE1/4, Section 17, Township 2 North, Range 14 West Scott T. Ford and Joan D. Ford, husband and wife 22311 Highway 10 Little Rock, Arkansas 72223 Part of the NW1/4 NE1/4 and part of the NE1/4 NW1/4 of Section 17, Township 2 North, Range 14 West; and Part of the SE1/4 SW1/4 and part of the SW1/4 SE1/4 of Section 8, Township 2 North, Range 14 West Rainwater Properties, LLC P. O. Box 3395 Little Rock, Arkansas 72203 Part of the SEl/4 SWIM and part of the SW1/4 SE1/4 of Section 8, Township 1 North, Range 14 West The Farmers & Merchants Bank by merger to Chart Bank P. O. Box 1010 Stuttgart, Arkansas 72160-1016 Part of the SW1/4 SE1/4 of Section 8, Township 2 North, Range 14 West Sam T. Hollowell, Jr. and Barbara Jane Hollowell, husband and wife, a/k/a Samuel T. Holloway, Jr. and Barbara Hollowell, husband and wife 23200 Highway 10 Little Rock, Arkansas 72223 Part of the SW1/4 SE1/4 of Section 8, Township 2 North, Range 14 West Frances H. Rowland, Trustee, of the Survivor's Trust "A" under the Herman M. Rowland and Frances H, Rowland Revocable Living Trust, and any amendments thereto, dated February 15, 2002; and Sam T. Hollowell, Jr. 23200 Highway 10 Little Rock, Arkansas 72223 This Ownership/Zone Search is intended for the exclusive use of the addressee for informational purposes only. Lenders Title Company is not expressing or attempting to express an opinion as to the validity of the title to the above described property or property noted as being within 200 feet thereof (collectively referred to as "the property"), the accuracy of the addresses, nor as to the validity of any interests or encumbrances, both recorded and unrecorded, that pertain to the property. While Lenders Title Company believes that the information stated above is accurate, no assurances are made nor is any liability assumed by Lenders Title Company for any incorrect information stated herein or omitted herefrom. For assurances as to the title to the property, addressee should obtain a title insurance commitment/policy, Sincerely, Lenders Title Company Arkansas License No.100111646 By: Title Agent License Number: 9895379 Issued at: LENDERS TITLE COMPANY One Allied Drive, Suite 1710 Little Bock, Arkansas 72202 Issuing Agent License No.100111046 sfpzd.doe 03/01 /10 NOTICE OF PUBLIC HEARING BEFORE THE LITTLE ROCK PLANNING COMMISSION ON AN APPLICATION TO ESTABLISH A SHORT -FORM PLANNED ZONING DEVELOPMENT To ALL owners of land lying within 200 feet of the boundary of the property located at: Address: ��'p j�f� d }� !C� n General Location: Owned by:��� NOTICE IS HEREBY GIVEN THAT an application for a Planned Zoning Development of the above property requesting a change of classification from District to e- — -3 POP has been filed with the Department o Planning and Development. A public hearing on said application will be held by the Little Rock Planning Commission in the Board of Directors Chamber, Second Floor, City HA on AW o S T / / 2,0 at Oft" F,4 % p.m. ALL PARTIES IN INTEREST MAY APPEAR and be heard at said time and place, or may notify the Planning Commission of their views on this matter by letter. All persons interested in this request are invited to call or visit the Department of Planning and Development, 723 W. Markham, 371-4790, and to review the application and discuss same with the Planning staff. . It 1 AFFIDAVIT I hereby certify that I have notified all the property owners of record within 200 feet of the above property that subject property is being considered for rezoning and that a Public Hearing will be held by the Little Rock Planning Commission at the time and place described above. Applicant (owner or authorized agent) G W�JL (Name) k / 1,oc6 (Date) City of Little Rock Department of Planning and Development Planning 723 West Markham Street Zoning and Little Rock, Arkansas 72201-1334 Subdivision Phone: (501) 371-4790 Fax: (501) 399-3435 or 371-6863 NOTICE OF PUBLIC HEARING BEFORE THE LITTLE ROCK PLANNING COMMISSION ON A REQUEST FOR A USE CHANGE OR DEVELOPMENT OF LAND July 11, 2016 Nowlin Creek Neighborhood Association Dan Hedges 9225 Twin Mountain Lane Roland, AR 72135 REQUEST: Porter Short -form PCD Z-9151 . a reguest to rezone the site from R-2, Single-family with a non -conforming designation to PCD Planned Commercial Development, to allow the use of the site with C-3 General Commercial District uses as well as limited outdoor display such as the existing playground equipment and/or plant materials associated with a plant nursery. GENERAL LOCATION OR ADDRESS: located on the southw stycorner of Highway 10 and Ferndale Cutoff Road OWNED BY/APPLICANT: Winifred Porter Trust Owner - Pat McGetrick En. inq eerie Agent 501.455.8899) NOTICE IS HEREBY GIVEN THAT an application for a Planned Zoning Development of the above property has been filed with the Department of Planning and Development. A public hearing will be held by the L.R. Planning Commission in the Little Rock Board of Directors Chambers, second floor, City Hall, 500 West Markham Street, on August 11, 2016 at 4:00 P.M. This notice is provided in order to assure that neighborhood associations are aware of issues that may affect their neighborhood. Information requests should be directed to the Planning staff at 371-4790. Tony Bozynski Director of Planning and Development ru Domestic Mail • nly rq •STVtt64 f AR' 7216 Ln Certified Mail Fee ru $J a 3+J �0033 I s 07. tra SarviCaS & Fees (check big odd rea - 1 ro7 El Return Receipt (hardeopy) $ - E:3 ❑ Return Receipt (electronic) S - Sri _ 00 Postmark C3 ❑ Certified Mail Restricted Delivery 6 $0.00 Here C3 []Adult Signature Required S sSrs 618 ]Adult Skjnnim Restricted Delivery $ � Postage _.-- s &13,4 07/26/20116 C:3 Total Postage and Fees „ $ $3.77 Ln ra Farmers & Merchant Bank 1 1% c/o Joann West S. ``- %D8 i11u r'h Stuttgart, AR 72160 Postal CERTIFIED !3 RECEIPT tt Domestic Mail • rTlY TT LE R[l�r A 722, 4 flu Mail Fee $3 a `0 rvices & Fees (chedrbotr,#dern 07 Receipt (hardcopy)rn Receipt (electronic S ��ified 71p Mall Restricted S �--- Here �lt Signature Required ? 5 lt Signature Restricted Oelt'ayDC3$0.47i7/26I2016 ostage and Fses $3.77 Scott Ford & Joan D. Ford ri C3 22311 Highway 10 r- Little Rock, AR 72223 co �1 CID /. Only . LITTLE ROCKI AR- 72223 .. Ill Certiffed Mail Fee- ru f+-+ S $3.30 C1C+33 FXtra $mice$ &Fees (check box, add fee stc) Q7 ❑ Return Receipt(hardcopy) $_} O ❑ Return Receipt (electronic) $ _ Postmark 0 ❑ Certified Mail Restricted Delivery $ $0. Here . `•i [-3 [-]Adult Signature Required $ — u�t---- [:]Adult Signature Restricted Osllyvty $ iU . O Postage 80+.47 0 TOW Postage and Feesit 07/ j/2Lf 6 $3.77 � Ford Family LTD Partnership N 22311 Highway 10 �rr� Little Rock, AR 72223 Er Domestic CO LITTLE ROCKi AR `7`2 +3 - Ln ru Certified Mall Fee $3. 30 003.3 07. tra Sem1pas & Fees {check bm6 add rao - ❑ Return Receipt (hardcopy) $ Sjj III I - -• - E:3 ❑ Return Receipt (electronic) $ go- Postmark E:3 ❑Certified Mail Restricted Delivery $F_ Here M ❑Adult Signature Required $-,.---. ❑ Adult Signature Restricted Delivery $ L-J Postage $i1.47 � S i l7/26/2016 Total Postage and Fees $3.77 $ I..rl "'71 Rainwater Properties, LLC C3 ram- P.O. Box 3395 Little Rock, AR 72203 y n_I I • • ro nly ro LITTLE .•? Ln .. r.. .. ru Certified !Nail Fee $3.30 ru sS Aft • Extra services & Fees (chew baX add too, AmarL7rey ❑Rutum Receipt (hardcopy) ❑ Return Receipt (electronic) $ [:3 ❑ Certified Mail Restricted Delivery $ I), no C3 []Adult Signature Required $ ❑ Adult Signature Restricted Dofivory $. O Postage $0 a 47 Total Postage and W. 77 SonTv16 4 s� 0033 07 Postmark Here 07/26/2016 PostalServiuirm CERTIFIED MAILP RECEIPT Ln Domestic Mail Only Co LITTC£ MCr �R.72223 Ln Cru ertified MaH fee 003 07 '� 5endcas &Fees (cheokboN, add red afv] ❑ Return Receipt (hardeopy) $ 0 ❑ Return Receipt (electronic) $ �---- POStmark i3 ❑ Certified Mail Restricted Delivery $ Here . C3 ❑ Adult Signature Required $ ❑ Adult Signature Restricted Delivery S. O Page 10.47 0 7 /26/2i 11 6 C3$ otal Postage and Fps $3.77 lJ7 Sant Tn _- Rowland C: Sam Hollowell/Frances C% 23200 Highway 10 Little Rock, AR 72223