Loading...
HomeMy WebLinkAboutZ-9131 Mapz a. I i ' 7' 7' 18' 18' PROPOSED CONCRETE PAD FOR DUMPSTER PROPERTY LINE — — 6' UTILITY EASEMENT ^ I PROPOSED CURB AND GUTTER (TYP.) 24' PROPOSED HANDICAP STALLS 24' PROPOSED CURB AND GUTTER (TYP.) 8Vl01NG 2A I 3! PROPOSED BUILDING 1,430 SF 28' R1p. 11' I // MENU BOARD // G/ / CP R8' G ✓// 413 / t� LEGEND (EXISTING) SYMBOLS LINEWORK o FOUND IRON PIN EASEMENT ? LIGHT POLE POWER POLE CURB m TELEPHONE PEDESTAL TV PEDESTAL INTERMEDIATE CONTOUR O MANHOLE INDEX CONTOUR 0 SANITARY SEWER CLEANOUT SS --SS 0 GAS METER SANITARY SEWER LINE DQ GAS VALVE G G GAS LINE G L--------- STORM SEWER PIPE W __ VV I DOWN GUY WATER LINE (SPECIFY SIZE & TYPE) D4 WATER VALVE U G T FIRE HYDRANT ASSEMBLY UNDERGROUND TELEPHONE C81 AIR RELEASE VALVE UGE — UNDERGROUND ELECTRIC y� 15, FIRE DEPARTMENT CONNECTION OHE "yI O WATER METER OVERHEAD ELECTRIC SPRINKLER HEAD UGTV UGTV m ELECTRIC PEDESTAL UNDERGROUND TELEVISION OHTV OHTV --- OVERHEAD TELEVISION GRATED INLET CHAIN LINK FENCE DROP INLET - L ==J WOOD FENCE BARBED WIRE FENCE ej TREE FO FIBER OPTIC TREE TO BE REMOVED RIGHT OF WAY ROAD CENTERLINE 4� SITE NOTES 1. THE DESIGN, INSPECTION, AND CERTIFICATION OF ANY RETAINING WALL SHOWN OR REFERENCED HEREIN, INCLUDING BUT NOT LIMITED TO, SEGMENTAL RETAINING WALLS, MASS GRAVITY WALLS, GABION WALLS, ETC., GREATER THAN FORTY-EIGHT INCHES IN HEIGHT, SHALL BE BY OTHERS. ANY RETAINING WALL DATA SHOWN OR REFERENCED HEREIN SHALL BE FOR COORDINATION OF THE WALL LOCATION AND ELEVATIONS ONLY. 2. ALL WORK AND MATERIALS SHALL COMPLY WITH ALL CITY/COUNTY/STATE/FEDERAL REGULATIONS AND CODES AND OSHA STANDARDS. 3. CONTRACTOR SHALL REFER TO ARCHITECTURAL PLANS FOR EXACT LOCATIONS AND DIMENSIONS OF VESTIBULES, SLOPE PAVING, SIDEWALKS, EXIT PORCHES, TRUCK DOCKS, PRECISE BUILDING DIMENSIONS AND EXACT UTILITY ENTRANCE LOCATIONS. 4. ALL DIMENSIONS AND RADII ARE TO BACK OF CURB UNLESS OTHERWISE NOTED. 5. ALL WORK SHALL BE DONE IN STRICT ACCORDANCE WITH THE PROJECT SPECIFICATIONS. 6. ALL CURB/SIDEWALK/HANDICAP RAMP DESIGNS SHALL CONFORM TO ADA STANDARDS OR LOCAL RESTRICTIVE CODES, WHICHEVER IS MORE RESTRICTIVE. 7. CONTRACTOR SHALL ENSURE ALL NECESSARY PERMITS ARE OBTAINED PRIOR TO CONSTRUCTION START. 8. CONTRACTOR SHALL MATCH PROPOSED CURB AND GUTTER, CONCRETE, AND PAVEMENT TO EXISTING IN GRADE AND ALIGNMENT. 9. CONTRACTOR SHALL MAINTAIN ALL EXISTING PARKING, SIDEWALKS, DRIVES, ETC. CLEAR AND FREE FROM ANY CONSTRUCTION ACTIVITY AND/OR MATERIAL TO ENSURE EASY AND SAFE PEDESTRIAN AND VEHICULAR TRAFFIC TO AND FROM THE SITE. VICINITY MAP NTS t� LEGEND (PROPOSED) SYMBOLS LINEWORK • SET IRON PIN LIGHT POLE )Ik POWER POLE ■ TELEPHONE PEDESTAL 0 TV PEDESTAL Q MANHOLE o SANITARY SEWER CLEANOUT ♦ GAS METER ►t GAS VALVE O STORM SEWER PIPE >-X STRUCTURE NUMBER N WATER VALVE ►� FIRE HYDRANT ASSEMBLY No AIR RELEASE VALVE FIRE DEPARTMENT CONNECTION O WATER METER B BACK FLOW PREVENTER • REDUCER ii PLUG VALVE RECTANGULAR DROP INLET, GRATED INLET OR JUNCTION BOX (SPECIFY ON PLAN SHEET) CIRCULAR DROP INLET, GRATED INLET OR JUNCTION BOX (SPECIFY ON PLAN SHEET) EASEMENT CURB 1206 INTERMEDIATE CONTOUR 120 INDEX CONTOUR SS SANITARY SEWER LINE G GAS LINE W WATER LINE UGT UNDERGROUND TELEPHONE UGE UNDERGROUND ELECTRIC OHE d OVERHEAD ELECTRIC FO FIBER OPTIC ucry UNDERGROUND TELEVISION OHTV OHTV OVERHEAD TELEVISION 0 CHAIN LINK FENCE 0 0 WOOD FENCE BARBED WIRE FENCE BUILDING SET BACK RIGHT OF WAY t GENERAL NOTES PROPERTY LINE — _ — _ — ROAD CENTERLINE 1. ENGINEER'S NOTICE TO CONTRACTOR: THE EXISTENCE AND LOCATION OF ANY UNDERGROUND UTILITY PIPES OR STRUCTURES SHOWN ON THESE DRAWINGS ARE OBTAINED BY A SEARCH OF THE AVAILABLE RECORDS. TO THE BEST OF OUR KNOWLEDGE THERE ARE NO EXISTING UTILITIES EXCEPT AS SHOWN ON THESE DRAWINGS AND WE ASSUME NO RESPONSIBILITY AS TO THE ACCURACY OF THEIR DEPICTED LOCATION ON THESE DRAWINGS. THE CONTRACTOR IS REQUIRED TO TAKE DUE PRECAUTIONARY MEASURES TO PROTECT THE UTILITY LINES SHOWN, AND ALL OTHER LINES NOT OF RECORD OR NOT SHOWN ON THESE DRAWINGS BY VERIFICATION OF THEIR LOCATION IN THE FIELD PRIOR TO THE INITIATION OF THE ACTUAL PORTION OF THEIR WORK. 2. SAFETY NOTICE TO CONTRACTOR: IN ACCORDANCE WITH GENERALLY ACCEPTED CONSTRUCTION PRACTICES, THE CONTRACTOR WILL BE SOLELY AND COMPLETELY RESPONSIBLE FOR CONDITIONS OF THE JOB SITE, INCLUDING SAFETY OF ALL PERSONS AND PROPERTY DURING PERFORMANCE OF THE WORK. THIS REQUIREMENT WILL APPLY CONTINUOUSLY AND NOT BE LIMITED TO NORMAL WORKING HOURS. THE DUTY OF THE ENGINEER TO CONDUCT CONSTRUCTION REVIEW OF THE CONTRACTOR'S PERFORMANCE ISNOT INTENDED TO INCLUDE REVIEW OF THE ADEQUACY OF THE CONTRACTOR'S SAFETY - MEASURES, IN, OR NEAR THE CONSTRUCTION SITE. 3. OWNERSHIP OF DOCUMENTS: THIS DOCUMENT, AND THE IDEAS AND DESIGNS INCORPORATED HEREIN, AS AN INSTRUMENT OF PROFESSIONAL SERVICES, IS THE PROPERTY OF CRAFTON TULL INC., AND IS NOT TO BE USED, IN WHOLE OR PART, FOR ANY OTHER PROJECT WITHOUT THE WRITTEN AUTHORIZATION OF CRAFTON TULL INC. 4. CONTRACTOR SHALL NOT CAUSE ANY INCONVENIENCE TO THE PUBLIC, ADJACENT PROPERTY OWNERS, PEDESTRIANS, ETC. DURING THE CONSTRUCTION OF THIS PROJECT, THE CONTRACTOR SHALL NOT DISRUPT ACCESS TO ADJACENT PROPERTIES AT ANY TIME DURING CONSTRUCTION. 5. THE CONTRACTOR SHALL CONTACT THE ENGINEER FOR CLARIFICATION IF A DISCREPANCY OR INCONSISTENCY IS IDENTIFIED ON THE PLANS AND/OR SPECIFICATIONS. 6. CONTRACTOR IS RESPONSIBLE FOR THE DESIGN AND IMPLEMENTATION OF ALL REQUIRED/NECESSARY SHEETING, SHORING, AND SPECIAL EXCAVATION MEASURES REQUIRED ON THE PROJECT TO MEET OSHA, FEDERAL, STATE AND LOCAL REGULATIONS. 7. CRAFTON TULL INC. (CIA) HAS NOT BEEN RETAINED BY THE OWNER FOR CONSTRUCTION ADMINISTRATION OR OBSERVATION SERVICES ON ALL OR A PORTION OF THE WORK INDICATED ON THESE DRAWINGS. THEREFORE, CTA HEREBY NOTIFIES ALL PARTIES INVOLVED THAT CTA ASSUMES NO RESPONSIBILITY FOR THE INTERPRETATION, COORDINATION AND ADMINISTRATION OF THESE DOCUMENTS AND/OR DEVIATIONS THEREFORE AND THE EFFECTS THOSE CHANGES MAY HAVE ON ANY AND ALL RELATED TRADES OR CONSTRUCTION SEQUENCES, OR OPERATION OF THE COMPLETED PROJECT, EXCEPT AS SPECIFICALLY REQUIRED IN THE CTA SERVICE AGREEMENT WITH THE OWNER. F , 0 0 00 ttl 1, LITTLE ROCK BOARD OF ADJUSTNW APPROVED SUBJECT "i O THE CONDITKIIIIIIIIII AS NOT" 1 .1 HC ..RD 4= A JUST ENF MINUTE REI,ORD DATED_. Z 2 BY: DATE: 3 / Arkansas One Call Know what's below. Cal before you dig. 10825 Financial Center Parkway, Suite 300 Little Rock, Arkansas 72211 Crafton Tull 0 engineering I surveying 501.664.3245 t 501.664.6704 f www.craftontull.com CERTIFICATE OF AUTHORIZATION: �,o0'F CRAFfON, TULL & - 1 ASSOCIATES, INC. D o! No. 109 q�MANSAS ENOIN�C0. GRAPHIC SCALE IN FEET 10' 0 10' REBSAMEN DEVELOPMENT LITTLE ROCK, ARKANSAS Key Plan No. Description Data This document, and the ideas and designs incorporated herein, as an instrument of professional service, is the property of Crafton, Tull & Associates, Inc., and is not to be used, in whole or in part, for any other project, without the written authorization of Crafton, Tull & Associates, Inc. �SIgUCTION PROJECT NO: °° RFG ISSUE DATE: 6/29/2016 �O� THIS 17- CONTACT: F. RIGGINS DOCUMENT IS N CHECKED BY: 2 PRELIMINARY IN NATURE AND IS NOT PRELIMINARY w A FINAL, SIGNED o PLANS AND SEALED DOCUMENT B 2015 Cra7ton, Tull & Associates, Inc. NOI-Lo0 SITE PLAN C-101 g0��