Loading...
HomeMy WebLinkAboutZ-9042 Staff AnalysisITEM NO.: 2. S-17 NAME: The Trails Subdivision Preliminary Plat LOCATION: located on the Southside of Kanis Road between the Chenal Downs Subdivision and Walnut Grove Road Plannina Staff Comments: 1. Provide notification of the abutting property owners of the development including the certified abstract list, notice form with affidavit executed and proof of mailing. The notice must be mailed no later than September 23, 2015. The Office of Planning and Development must receive the proof of notice no later than October 2, 2015. 2. The plat as presently submitted includes variances for lot depth to widths along the ridge lots and also Lots 117 — 118. 3. The plat indicates a reduced front building setback for Lots 41 — 45. The building setback required for a residential street is 25-feet. The lots along Natural Trail are indicated at 30-feet and 20-feet. 4. Remove all building setbacks except for the front building setback. Note on the plal the side and rear yard setbacks will comply with the zoning ordinance for R-2, Single-family zoned property. 5. If the lots abutting Kanis Road continue to have frontage on Kanis Road a restrictive access easement (10-feet) is required along the Kanis Road frontage which will prohibit drives from taking access to Kanis Road. This will allow the lots to be reverse frontage lots and not considered double frontage lots. 6. Provide the proposed phasing plan for the subdivision. Provide the proposed phasing plan for the street improvements to Kanis Road. Variance/Waivers: Public Works Conditions: 1. Kanis Road is classified on the Master Street Plan as a minor arterial. A dedication of right-of-way 45 feet from centerline will be required. 2. With site development, provide design of street conforming to the Master Street Plan. Construct one-half street improvement to Kanis Road with the planned development. Kanis Road should be improved with pavement provided to 11 feet from centerline and a 4 foot gravel shoulder. At the proposed street intersections at least 36 feet of asphalt should be provided with striping for a left turn lane. Paving should be provided for lane shifts and striping to meet AASHTO standards may extend beyond the property boundary. 3. Stormwater detention ordinance applies to this property. 4. If disturbed area is one (1) or more acres, obtain a NPDES stormwater permit from the Arkansas Department of Environmental Quality prior to the start of construction. 5. Kanis Road is on the Master Bike Plan. If bike lanes are desired per the Master Bike Plan and MUTCD standards, the bike lanes should be 6 feet wide measured from the back of curb and provided on both sides of the proposed street. The bike lanes should continue on Kanis Road east and west of the proposed intersections to the side property lines. The paved lane should be 5 feet wide with striping and takes the place of the 4 feet gravel shoulder in these areas. 6. Provide the typical street cross section for each street. 7. Provide a Sketch Grading and Drainage Plan per Section 29-186 that shows proposed street and lot grades. 8. Local streets centerline grade cannot exceed 15% without approval of a variance to the Master Street Plan. Local streets centerline grade cannot exceed 5% at the first 30 feet of an intersection. 9. Floodplain is shown on the subject property. Contact Pulaski County Road and Bridge for floodplain regulations and conditions. 10. Alteration of the water course will require approval from the Little Rock District of the US Army Corps of Engineers prior to start of work. 11. Street Improvement plans shall include signage and striping. Public Works must approve completed plans prior to construction. 12.In accordance with Section 31-176, floodway areas must be shown as floodway easements or be dedicated to the public. In addition, a 25 foot wide drainage and access easement is required adjacent to the floodway boundary. 13. Streetlights are required by Section 31-403 of the Little Rock code. Provide plans for approval to Traffic Engineering. Streetlights must be installed prior to platting/certificate of occupancy. Contact Traffic Engineering, Greg Simmons, gsimmons@littlerock.org or 501.379.1813 for more information 14. Per the Master Street Plan, parking is restricted to one side of the street on a 24 feet wide street. Show on the plan now and on the final plat and bill of assurance, the area along the street where parking is not allowed. 15. Damage to public and private property due to hauling operations or operation of construction related equipment from a nearby construction site shall be repaired by the responsible party prior to issuance of a certificate of occupancy. 16.A minimum undisturbed strip 25 foot wide except for reasonable access shall be provided along each side of streams having a 10 year storm >150 cfs. The undisturbed strip should be measured from the top of the bank. 17. The minimum finish floor elevation as required by Pulaski County is required to be shown on plat and grading plans for lots in or adjacent to the floodplain. 18. Plans of all work in right-of-way shall be submitted for approval prior to start of work. 19. Provide a letter prepared by a registered engineer certifying the sight distance at the Kanis Road intersection(s) comply with 2004 AASHTO Green Book standards. 20. Repair or replace any curb and gutter or sidewalk that is damaged in the public right- of-way prior to occupancy. 21. The proposed traffic circle should be constructed per AASHTO and FHWA standards with bike lanes and splitter islands. Contact Nat Banihatti in Traffic Engineering nbanihatti(u-)_1itt1erock,orq or 501.379.1818 for additional information. 22.Traffic calming devices are required for long straight streets to discourage speeding. Traffic circles or round-abouts are suggested at regular intervals and at main intersections. Contact Travis Herbner in Traffic Engineering therbner littlerock.or or 501.379.1805 for additional information. 23. The acceleration and deceleration lanes on Kanis Road should not be constructed. 24. Walnut Grove Road is classified on the Master Street Plan as a principal arterial. Dedication of right-of-way to 55 feet from centerline will be required. Per the Master Street Plan at the intersection of arterial/arterial intersections, an additional 10 feet of right-of-way should be dedicated for a right turn. 25. Per the Master Street Plan at arterial/arterial intersections, a 100 foot radial dedication of right-of-way is required at the intersection of Walnut Grove Road and Kanis Road. 26. Sidewalks with appropriate handicap ramps are required in accordance with Section 31-175 of the Little Rock Code and the Master Street Plan. 27. The minimum stopping sight distance of 155 feet or latest AASHTO policy on Geometric Design Manual and 150 foot minimum horizontal radius at centerline must be provided. Utilities and Fire Department/County Planning: Wastewater: Outside the service boundary. No comment. Entergy: Entergy does not object to this proposal. There are no conflicts with existing Entergy facilities. However, for a development of this magnitude a three phase line is usually required to be able to divide the electrical load to serve all the proposed lots. The nearest 3 phase line is approximately 0.75 miles to the west of this property. Contact Entergy well in advance regarding future service requirements to the development so that line extensions can be planned and an electrical layout can be developed as this project proceeds. CenterPoint Energy: No comment received. AT & T: No comment received. Central Arkansas Water: 1. All Central Arkansas Water requirements in effect at the time of request for water service must be met. 2. A water main extension will be needed to provide water service to this property. 3. Please submit plans for water facilities and/or fire protection system to Central Arkansas Water for review. Plan revisions may be required after additional review. Contact Central Arkansas Water regarding procedures for installation of water facilities and/or fire service. Approval of plans by the Arkansas Department of Health Engineering Division and the Little Rock Fire Department is required. 4. This development will have minor impact on the existing water distribution system. Proposed water facilities will be sized to provide adequate pressure and fire protection. 5. A Capital Investment Charge based on the size of meter connection(s) will apply to this project in addition to normal charges. This fee will apply to all connections including metered connections off the private fire system. 6. If there are facilities that need to be adjusted and/or relocated, contact Central Arkansas Water. That work would be done at the expense of the developer. 7. Additional fire hydrant(s) will be required. Contact the Little Rock Fire Department to obtain information regarding the required placement of the hydrant(s) and contact Central Arkansas Water regarding procedures for installation of the hydrant(s). Fire Department: Maintain Access: Fire Hydrants. Maintain fire apparatus access roads at fire hydrant locations as per Appendix D of the 2012 Arkansas Fire Prevention Code Vol. 1 Section D103.1 Access road width with a hydrant. Where a fire hydrant is located on a fire apparatus access road, the minimum road width shall be 26 feet, exclusive of shoulders. Grade - Maintain fire apparatus access roads as per Appendix D of the 2012 Arkansas Fire Prevention Code Vol. 1 Section D103.2 Grade. Fire apparatus access roads shall not exceed 10 percent in grade except as approved by the fire chief. Loading - Maintain fire apparatus access road design as per Appendix D of the 2012 Arkansas Fire Prevention Code Vol. 1 Section D102.1 Access and loading. Facilities, buildings or portions of buildings hereafter constructed shall be accessible to fire department apparatus by way of an approved fire apparatus access road with an asphalt, concrete or other approved driving surface capable of supporting the imposed load of fire apparatus weighing at least 75,000 pounds. Gates - Maintain fire apparatus access road gates as per Appendix D of the 2012 Arkansas Fire Prevention Code Vol. 1 Section D103.5 Fire apparatus access road gates. Gates securing the fire apparatus access roads shall comply with all of the following criteria: 1. Minimum gate width shall be 20 feet. 2. Gates shall be of swinging or sliding type. 3. Construction of gates shall be of material that allow manual operation by one person. 4. Gate components shall be maintained in an operable condition at all times and replaces or repaired when defective. 5. Electric gates shall be equipped with a means of opening the gate by fire department personnel for emergency access. Emergency opening devices shall be approved by the fire code official. 6. Manual opening gates shall not be locked with a padlock or chain and padlock unless they are capable of being opened by means of forcible entry tools or when a key box containing the keys to the lock is installed at the gate location. 7. Locking device specifications shall be submitted for approval \by the fire code official 8. Electric gate operators, where provided, shall be listed in accordance with UL 325. 9. Gates, intended for automatic operation shall be designed, constructed and installed to comply with requirements of ASTM F 2200. One- or Two -Family Residential Developments. As per Appendix D, Section D107.1 of the Arkansas Fire Prevention Code Vol. 1, One- or Two -Family dwelling residential developments. Developments of one- or two-family dwellings where the number of dwelling units exceeds 30 shall be provided with two separate and approved fire apparatus access roads, and shall meet the requirements of Section D104.3. Exceptions: 1. Where there are more than 30 dwelling units on a single public or private fire apparatus access road and al dwelling units are equipped throughout with an approved automatic sprinkler system in accordance with Section 903.3.1.1, 903.3.1.2 or 903.3.1.3 of the Arkansas Fire Code, access from two directions shall not be required. 2. The number of dwelling units on a single fire apparatus access road shall not be increased unless fire apparatus access roads will connect with future development, as determined by the fire code official. Fire Hydrants - Locate Fire Hydrants as per Appendix C of the 2012 Arkansas Fire Prevention Code. Section C101 — C105, in conjunction with Central Arkansas Water (Jason Lowder 501.377.1245) and the Little Rock Fire Marshal's Office (Captain Tony Rhodes 501.918.3757 or Capt. John Hogue 501-918-3754). Number and Distribution of Fire Hydrants as per Table C105.1. Parks and Recreation: No comment received. County Planning 1. Provide bill of assurance. 2. Label index contour on all plan sheets. 3. Show each lot size in acres and square feet. 4. Provide CAW approval letter for water supply. 5. Provide Health Department approval of wastewater treatment system. 6. Provide revised approval letter from Volunteer Fire Department. 7. Provide cross section of all streets. 8. Provide design profile for all streets. 9. Label all street centerlines. 10. Provide storm drainage plan. 11. Provide effective FEMA flood panel number. 12. Provide Pulaski County preliminary certificate of approval, not final. 13. Street names in proposed subdivision (Sunshine and Horizon) are identical to other streets within Pulaski County, rename streets as needed to avoid conflict. 14. Provide full set of construction plans for all streets once preliminary plat is approved by the City of Little Rock and Pulaski County. 15. Front, rear and side setbacks do not comply with Pulaski County Subdivision and Development Code standards. 25-front and rear setback required and 8-foot side yard setbacks are required (reference 15-foot building setback on large lot diagram on cover plan near north arrow.) 16. Provide SWPPP for Pulaski County Review. a. Provide water and wastewater design plans for Public Works review. b. Provide for maintenance of greenways, common areas, trails, wastewater plant and all leftover tracts in the bill of assurance and on the plat. c. Obtain appropriate road cut permits from Pulaski County Public Works for Kanis Road. d. Provide sight distance certification for all new roads connecting to Kanis Road. Include in certification verification that Walnut Grove/Natural Trail spacing complies with Master Road Plan requirements for arterial spacing with speeds of 45 MPH or greater. e. Lot 266 is out of sequence. f. Provide turnarounds at maximum 900-foot intervals for all cul-de-sac streets. g. Provide drainage easements as needed between and behind lots. h. Dedicate right of way as required to the northeast side of Walnut Grove Road to comply with City of Little Rock Master Street Plan along entire Trails Subdivision frontage. i. Right of way for Kanis Road meets Master Road Plan standards. Provide design plans for any half street improvements on Kanis Road required by the City of Little Rock and Pulaski County. ROCK REGION METRO: Building Code: No comment. Planning Division: No comment. Landscape: No comment. Revised plat/plan: Submit four (4) copies of a revised preliminary plat/plan (to include the additional information as noted above) to staff on Wednesday, September 23, 2015. January 7, 2016 ITEM NO.: E NAME: The Trails Conditional Use Permit FILE NO.: Z-9042 LOCATION: Located on the Southside of Kanis Road between the Chenal Downs Subdivision and Walnut Grove Road DEVELOPER. Wayne Richie 17200 Chenal Parkway, Suite 300 — 351 Little Rock, AR 72223 ENGINEER: Phillip Lewis Engineering 2701 Kavanaugh Boulevard, Suite 200 Little Rock, AR 72205 AREA: 154-acres NUMBER OF LOTS: 299 FT. NEW STREET: 13,820 LF PROPOSAL: The applicant is requesting approval of a Conditional Use Permit to allow for construction of a wastewater and treatment system to serve a proposed single-family subdivision. VARIANCEMAIVERS: None requested. 1. SITE LOCATION: The property is located on the South side of Kanis Road just west of the Chenal Downs Subdivision and just East of Walnut Grove Road. 2. COMPATIBILITY WITH NEIGHBORHOOD: Kanis Road is a narrow unimproved road with open ditches for drainage. The property is located outside the City limits of Little Rock but within the City's Extraterritorial Planning Jurisdiction. The area is primarily single-family with homes located on acreage. The property is undeveloped with varying degrees of slope. A portion of the property is wooded, with a portion being pastureland. The general area contains January 7, 2016 SUBDIVISION ITEM NO.: E (Cont.) FILE NO.: Z-9042 single-family residences, including manufactured homes, on large lots along Kanis and Burlingame Roads. Chenal Downs, a 5-acre subdivision, abuts the property to the east. Property zoned AF, Agriculture and Forestry bounds the properties southern boundary. As of this writing, staff has received a number of phone calls both informational and with concerns related to the request from area residents. All property owners located within 200-feet of the site were notified of the public hearing. There is not an active City recognized neighborhood association located in the area. 3. ON SITE DRIVES AND PARKING: As a separate item on this agenda the applicant is proposing a Planned Residential Development to allow the development of 154-acres with 299-single- family homes to be developed with public streets developed to County Standards per the County's Master Road Plan. The subdivision will be served by a centralized wastewater collection treatment system which necessitates the approval of a Conditional Use Permit. 4. SCREENING AND BUFFERS: Landscape: No comment. The development is proposed as a single-family subdivision homes constructed on individual lots. The wastewater collection site is located in the western portion of the property. 5. PUBLIC WORKS COMMENTS: 1. Kanis Road is classified on the Master Street Plan as a minor arterial. A dedication of right-of-way 45 feet from centerline will be required. 2. Some floodplain is identified on the subject property. Contact Pulaski County Road and Bridge about the conditions for developing in the 100 year floodplain. 6. UTILITY/FIRE DEPARTMENT/COUNTY PLANNING/CATA/BUILDING CODES: Wastewater: Outside the service boundary. No comment. Entergy: Entergy does not object to this proposal. A single phase power line exists on the western side of the property, but nowhere else. Service to the proposed lots will be installed and provided along the front lot lines along the new 2 January 7, 2016 SUBDIVISION ITEM NO.: E Cont. FILE NO.: Z-9042 streets. Contact Entergy in advance regarding future service requirements and additional facilities location(s) as this development will require extensive work to install facilities to the 299 proposed lots. Centerpoint Energy: No comment received. AT & T: No comment received. Central Arkansas Water: 1. All Central Arkansas Water requirements in effect at the time of request for water service must be met. 2. A water main extension will be needed to provide water service to this property. 3. Please submit plans for water facilities and/or fire protection system to Central Arkansas Water for review. Plan revisions may be required after additional review. Contact Central Arkansas Water regarding procedures for installation of water facilities and/or fire service. Approval of plans by the Arkansas Department of Health Engineering Division and the Little Rock Fire Department is required. 4. This development will have minor impact on the existing water distribution system. Proposed water facilities will be sized to provide adequate pressure and fire protection. 5. If there are facilities that need to be adjusted and/or relocated, contact Central Arkansas Water. That work would be done at the expense of the developer. 6. Additional fire hydrant(s) will be required. Contact the Little Rock Fire Department to obtain information regarding the required placement of the hydrant(s) and contact Central Arkansas Water regarding procedures for installation of the hydrant(s). 7. A Capital Investment Charge based on the size of meter connection(s) will apply to this project in addition to normal charges. This fee will apply to all connections including metered connections off the private fire system. West Pulaski Fire Protection District #323: The West Pulaski Fire Protection District #23 serves this area. Fire hydrants and water lines will need to meet or exceed the specifications containing in the agreement with Central Arkansas Water and the Volunteer Fire Departments in Pulaski County. Also, cul de sacs and speed round abouts will need to be of sufficient widths to allow for fire apparatus to easily maneuver. The proposed bicycle path in the subdivision will 9 January 7, 2016 SUBDIVISION ITEM NO.: E Cont.) FILE NO.: Z-9042 enhance safety for bicyclists with an alternate route to the portion of Kanis Road known as the Hollow which runs from Chenal Downs to Walnut Grove Road. This stretch of road has no shoulders with drop offs and closely lined with trees. During inclement weather many times this portion of Kanis is not passable due to debris from downed trees (motor vehicle accidents, too), and the main road in the subdivision will allow traffic to be diverted around it. Lastly, westward progression of water lines towards, Ferndale, enables the fire department to have more reliable water sources to fight fires and less reliance on water shuttle operations that are hazardous. Fire Department: Maintain Access. Fire Hydrants. Maintain fire apparatus access roads at fire hydrant locations as per Appendix D of the 2012 Arkansas Fire Prevention Code Vol. 1 Section D103.1 Access road width with a hydrant. Where a fire hydrant is located on a fire apparatus access road, the minimum road width shall be 26 feet, exclusive of shoulders. Grade. Maintain fire apparatus access roads as per Appendix D of the 2012 Arkansas Fire Prevention Code Vol. 1 Section D103.2 Grade. Fire apparatus access roads shall not exceed 10 percent in grade except as approved by the fire chief. Loading. Maintain fire apparatus access road design as per Appendix D of the 2012 Arkansas Fire Prevention Code Vol. 1 Section D102.1 Access and loading. Facilities, buildings or portions of buildings hereafter constructed shall be accessible to fire department apparatus by way of an approved fire apparatus access road with an asphalt, concrete or other approved driving surface capable of supporting the imposed load of fire apparatus weighing at least 75,000 pounds. Dead Ends. Maintain fire apparatus access roads at dead end locations as per Appendix D of the 2012 Arkansas Fire Prevention Code Vol. 1 Section D103.4 Dead Ends. Dead-end fire apparatus access roads in excess of 150 feet shall be provided with width and turnaround provisions in accordance with Table D103.4. Requirements for Dead-end fire apparatus access roads. Gates. Maintain fire apparatus access road gates as per Appendix D of the 2012 Arkansas Fire Prevention Code Vol. 1 Section D103.5 Fire apparatus access road gates. Gates securing the fire apparatus access roads shall comply with all of the following criteria: 1. Minimum gate width shall be 20 feet. 2. Gates shall be of swinging or sliding type. 0 January 7, 2016 SUBDIVISIO ITEM NO.: E Cont. FILE NO.: 7-9042 3. Construction of gates shall be of material that allow manual operation by one person. 4. Gate components shall be maintained in an operable condition at all times and replaces or repaired when defective. 5. Electric gates shall be equipped with a means of opening the gate by fire department personnel for emergency access. Emergency opening devices shall be approved by the fire code official. 6. Manual opening gates shall not be locked with a padlock or chain and padlock unless they are capable of being opened by means of forcible entry tools or when a key box containing the keys to the lock is installed at the gate location. 7. Locking device specifications shall be submitted for approval by the fire code official 8. Electric gate operators, where provided, shall be listed in accordance with UL 325. 9. Gates, intended for automatic operation shall be designed, constructed and installed to comply with requirements of ASTM F 2200. One- or Two -Family Residential Developments. There are going to be over 30 houses and code requires two separate access roads, need to connect the roads inside the housing development. As per Appendix D, Section D107.1 of the Arkansas Fire Prevention Code Vol. 1, One- or Two -Family dwelling residential developments. Developments of one- or two-family dwellings where the number of dwelling units exceeds 30 shall be provided with two separate and approved fire apparatus access roads, and shall meet the requirements of Section D104.3. Exceptions: 1. Where there are more than 30 dwelling units on a single public or private fire apparatus access road and al dwelling units are equipped throughout with an approved automatic sprinkler system in accordance with Section 903.3.1.1, 903.3.1.2 or 903.3.1.3 of the Arkansas Fire Code, access from two directions shall not be required. 2. The number of dwelling units on a single fire apparatus access road shall not be increased unless fire apparatus access roads will connect with future development, as determined by the fire code official. January 7, 2016 SUBDIVISION ITEM NO.: E Cont. FILE NO.: Z-9042 Fire Hydrants. Locate Fire Hydrants as per Appendix C of the 2012 Arkansas Fire Prevention Code. Section C101 — C105, in conjunction with Central Arkansas Water (Jason Lowder 501.377.1245) and the Little Rock Fire Marshal's Office (Capt. Tony Rhodes 501.918.3757). Number and Distribution of Fire Hydrants as per Table C105.1. Parks and Recreation: No comment received. County Planning: 1. Provide Arkansas Department of Health approval for wastewater treatment system. 2. Provide water and wastewater design plans for Public Works review. 3. Provide for maintenance of greenways, common areas, trails, wastewater plant and all leftover tracts in the bill of assurance and on the plat. CATA: The site is located in an area which is presently not served by CATA. Building Code: No Comment 7. SUBDIVISION COMMITTEE COMMENT: (May 13, 2015) Mr. Phillip Lewis and Mr. Wayne Richie were present representing the request. Staff presented an overview of the item stating there were a number of outstanding technical issues associated with the request in need of addressing. Staff stated there were two (2) applications for this development being considered. Staff stated one (1) item was related to the PD-R zoning and the creation of the preliminary plat. Staff stated the second was consideration and approval of a Conditional Use Permit to allow the construction of a wastewater treatment facility to serve the wastewater disposal needs of the new homes. Staff requested information concerning the proposed wastewater treatment system and how the system would be permitted, operation of the system and the type system to be used. For the proposed subdivision staff requested details of the proposed subdivision identification sign. Staff also requested information concerning proposed fences and outbuildings. Staff requested Mr. Lewis provide the square footages of the proposed homes. Staff also questioned the proposed phasing plan. Public Works comments were addressed. Staff stated Kanis Road was classified on the Master Street Plan as a minor arterial. Staff stated a right of way dedication to 45-feet from centerline was required. Staff stated the street 0 January 7, 2016 SUBDIVISION ITEM NO.: E Cont. FILE NO., Z-9042 construction was to be two (2) 11-foot drive lanes and a 4-foot aggregate shoulder. Staff stated per the Master Street Plan parking on residential streets indicated at 24-feet in width was limited to one (1) side. Staff stated plans for all work in the right of way was to be submitted for approval prior to the start of construction. Staff requested Mr. Lewis provide a sight distance certification for the two (2) access points of the new street with Kanis Road. Staff stated the minimum finished floor elevation as required by Pulaski County was required to be shown on the plat and the grading plans. Staff noted the comments from the various other agencies. There were no more issues for discussion. The Committee then forwarded the item to the full Commission for final action. 8. ANALYSIS: The applicant provided additional information concerning the proposed wastewater treatment system as requested at the May 13, 2015, Subdivision Committee meeting. The zoning ordinance defiles water or sewage treatment plant and related facilities to mean a facility for the systematic collection and treatment and dispersal of water and waste materials. Section 36-104 states uses exclusively conditional or otherwise restricted uses include water and wastewater treatment system plants unless located within the 1-2, Light Industrial zoning district. The applicant is proposing a plant which is a modular, fully plumbed treatment plant capable of handling flows from 5000 gpd up to 1 mgd. The system is built inside an insulated fiberglass tank. The tank can be installed above ground or below ground, singularly or in multi -tank arrays. The system will be collected via a combination of gravity collection sewer and tight line forced mains and conveyed to a package treatment plant located south of the larger of two (2) proposed ponds. The plant will utilize the biological extended aeration principle of operation, a variation of the activated sludge process. The discharge of the plant will be released into the adjacent larger pond. The flow from the spillway of the larger pond will ultimately discharge into Fletcher Creek to the west of the pond. The plant will be recessed below grade for aesthetics and noise control. The wastewater treatment plant will be designed, permitted and constructed in accordance with the requirements of the Arkansas Department of Environmental Quality (ADEQ) and the Arkansas Department of Health. Staff is not supportive of the proposed PD-R rezoning request and without approval of the zoning request the CUP for the wastewater treatment system is not necessary. 7 January 7, 2016 SUBDIVISION ITEM NO.: E Cont. FILE NO.: Z-9042 9. STAFF RECOMMENDATION: Staff recommends denial of the request. PLANNING COMMISSION ACTION: (JUNE 4, 2015) The applicant was present. There were no registered objectors present. Staff presented the item stating the applicant had submitted a request dated May 29, 2015, requesting deferral of this item to the July 16, 2015, public hearing. Staff stated they were supportive of the deferral request. There was no further discussion. The item was placed on the consent agenda and approved as recommended by staff by a vote of 8 ayes, 0 noes and 3 absent. STAFF UPDATE: The Conditional Use Permit (CUP) application request has not changed. The applicant is seeking approval of a CUP to allow a wastewater treatment system to serve the proposed single-family subdivision, The Trails Long -form PD-R. The discharge of the treatment plant will be Fletcher Creek. Prior to any activity on the site the applicant must seek approval from the Arkansas Department of Health and the Arkansas Department of Environment Quality for the placement of the treatment plant and the discharge to the adjacent creek. Once again staff is not supportive of the proposed PD-R rezoning request and without approval of the zoning request the CUP for the wastewater treatment plant is not necessary. PLANNING COMMISSION ACTION: (JULY 16, 2015) The applicant was present. There were no registered objectors present. Staff presented the item stating the applicant was requesting a deferral of the item to the October 8, 2015, public hearing. Staff stated they were supportive of the deferral request. There was no further discussion. The item was placed on the consent agenda and approved as recommended by staff by a vote of 11 ayes, 0 noes and 0 absent. STAFF UPDATE: This application is a companion application to a preliminary plat for the Trails Subdivision (S-1758) to allow the development of a single-family subdivision with 266 single-family homes. Access to the treatment plant is via an access road to the treatment plant extending from Twilight Trail to the proposed plant. In the area proposed for the treatment plant there are few homes. There is a single-family home E:3 January 7, 2016 SUBDIVISION 111:1 TA10416 i:411111510TOTi1# FILE NO.: Z-9042 located approximately 650-feet (as measured from the City's GIS) from the area proposed for the treatment plant. The wastewater from the homes will be collected via a combination of gravity collection sewer and tight line forced mains and conveyed to a packaged treatment plant located south of the larger of the two (2) ponds proposed with the plat. The plant will utilize the biological extended aeration principle of operation, a variation of the activated sludge process. The discharge of the plant will be released into the adjacent larger pond. The flow from the spillway of the larger pond will ultimately discharge into Fletcher Creek to the west of the pond. The plant will be recessed below grade for aesthetics and noise control. The wastewater treatment plant will be designed, permitted and constructed in accordance with requirements of the Arkansas Department of Health and the Arkansas Department of Environmental Quality (ADEQ). The plant will be developed in phases with the initial construction sized to accommodate the development of the first few phases. As subsequent phases are developed the treatment plant will be enlarged to accommodate the new flows. The phasing of the plant installation allows the treatment plant to be sized to accommodate the homes that that phase is serving. The staging is a benefit in that should the entire subdivision not develop or develop at a slower pace than the developer anticipates the residents living in the subdivision can pay the cost of operations and maintenance of the treatment system. The proposed Bill of Assurance outlines the "community system", the wastewater disposal system. The Bill of Assurance states the "community system" will be constructed by the developer and maintained by the developer and/or his agent as dictated by the laws of the State of Arkansas. Maintenance and operation of the "community system" will be performed by a Class II or Class III operator approved by the Arkansas Department of Environmental Quality (ADEQ). Landscaping on the site will be in accordance to Chapter 15, Article IV of the City of Little Rock's Municipal Code. A minimum 50 foot buffer will be maintained from any necessary structures to the property line around the entire perimeter. The existing vegetation in the buffer zone, as well as, future building areas will be undisturbed to the maximum extent practical. Areas that must be disturbed during construction will be reestablished. On -site lighting will be in compliance with "dark sky" guidelines. However, sufficient lighting will be used for OSHA standards as needed for maintenance and security. Staff is continuing to review the proposed wastewater treatment plant. Staff recommendation is forthcoming on the conditional use permit request. �6] January 7, 2016 SUBDIVISION ITEM NO.: E (Cont. FILE NO.: Z-9042 PLANNING COMMISSION ACTION: (OCTOBER 8, 2015) The applicant was present. There were a number of registered objectors present. Staff presented the item stating the applicant was seeking a deferral of the item. Staff stated the deferral request would require a waiver of the Commissions By-laws with regard to the number of previous deferral requests. Staff stated the Commission's By-laws allowed the applicant to request two (2) deferrals which had already been granted. Staff stated they were not supportive of the deferral request. Staff stated they felt the applicant had sufficient time to address their concerns and did not favor the deferral request. Commissioner Berry stated he felt the developer should be granted the deferral. He stated the request was a complex request and would take time to work through all the issues. Commissioner Berry stated the Commission at their discretion could defer an item to obtain additional information. Commissioner Berry stated he felt there were a number of outstanding technical issues which had not been addressed by the applicant. Commissioner Berry made a motion to defer the request to the January 7, 2016, public hearing. The motion carried by a vote of 8 ayes, 0 noes, 2 absent and 1 abstention (Commissioner May). STAFF UPDATE: The applicant submitted a request dated December 23, 2015, requesting withdrawal of this item without prejudice. Staff is supportive of the withdrawal request. PLANNING COMMISSION ACTION: (JANUARY 7, 2016) The applicant was present. There were no registered objectors present. Staff presented the item stating the applicant had submitted a request dated December 23, 2015, requesting withdrawal of this item without prejudice. Staff stated they were supportive of the withdrawal request. There was no further discussion. The item was placed on the consent agenda and approved as recommended by staff by a vote of 10 ayes, 0 noes and 1 absent. 10 ITEM NO.: 19, NAME: The Trails Conditional Use Permit Z-9042 LOCATION: located on the Southside of Kanis Road between the Chenal Downs Subdivision and Walnut Grove Road Planning Staff Comments, 1. Provide notification of the property owners located within 200-feet of the development including the certified abstract list, notice form with affidavit executed and proof of mailing. The notice must be mailed no later than May 20, 2015. The Office of Planning and Development must receive the proof of notice no later than May 29, 2015. 2. Provided details of the proposed treatment system, who will permit (State Agency), who will be responsible for maintenance (Property Owners Association/Developer), what are the required setbacks from adjacent properties, what are the discharge requirements and/or perimeters for disposal of treated effluent. 3. Has a permit request been made to the proper permitting agencies to allow for the proposed treatment system? 4. Will the system be located above or below the ground? 5. All subdivisions shall be provided with water supply and distribution systems approved by the city and meeting the requirements of the state health department. Where a public water supply is within a reasonable distance of the subdivision, the subdivider shall install or have installed a system of water mains and connect to such supply. A connection to each lot shall be installed prior to the paving of the street, if possible. 6. Section 31-400 - All subdivisions shall be provided with a sewage collection and treatment system approved by the wastewater utility and/or the state board of health. Where a public sanitary sewer is within a reasonable distance of any point of a subdivision, the subdivider shall connect with such sewer and provide a connection to each lot. Such sanitary sewage system shall be installed prior to the installation of the street pavement. The sewage collection system shall be designed to handle the anticipated flow of sewage from within the subdivision, including development of future sections of the same subdivision and adjacent areas within the same drainage basin. Recognized engineering design criteria in accordance with the state department of health shall be used to design the system. Variance/Waivers: None requested. Public Works Conditions: 1. Kanis Road is classified on the Master Street Plan as a minor arterial. A dedication of right-of-way 45 feet from centerline will be required. 2. Some floodplain is identified on the subject property. Contact Pulaski County Road and Bridge about the conditions for developing in the 100 year floodplain. Utilities and Fire Department/County Planning: Wastewater: Outside the service boundary. No comment. Entergy: Entergy does not object to this proposal. A single phase power line exists on the western side of the property, but nowhere else. Service to the proposed lots will be installed and provided along the front lot lines along the new streets. Contact Entergy in advance regarding future service requirements and additional facilities location(s) as this development will require extensive work to install facilities to the 299 proposed lots. Centerpoint Ener : No comment received. AT & T: No comment received. Central Arkansas Water: 1. All Central Arkansas Water requirements in effect at the time of request for water service must be met. 2. A water main extension will be needed to provide water service to this property. 3. Please submit plans for water facilities and/or fire protection system to Central Arkansas Water for review. Plan revisions may be required after additional review. Contact Central Arkansas Water regarding procedures for installation of water facilities and/or fire service. Approval of plans by the Arkansas Department of Health Engineering Division and the Little Rock Fire Department is required. 4. This development will have minor impact on the existing water distribution system. Proposed water facilities will be sized to provide adequate pressure and fire protection. 5. If there are facilities that need to be adjusted and/or relocated, contact Central Arkansas Water. That work would be done at the expense of the developer. 6. Additional fire hydrant(s) will be required. Contact the Little Rock Fire Department to obtain information regarding the required placement of the hydrant(s) and contact Central Arkansas Water regarding procedures for installation of the hydrant(s). 7. A Capital Investment Charge based on the size of meter connection(s) will apply to this project in addition to normal charges. This fee will apply to all connections including metered connections off the private fire system. Fire Department- Maintain Access. Fire Hydrants. Maintain fire apparatus access roads at fire hydrant locations as per Appendix D of the 2012 Arkansas Fire Prevention Code Vol. 1 Section D103.1 Access road width with a hydrant. Where a fire hydrant is located on a fire apparatus access road, the minimum road width shall be 26 feet, exclusive of shoulders. Grade. Maintain fire apparatus access roads as per Appendix D of the 2012 Arkansas Fire Prevention Code Vol. 1 Section D103.2 Grade. Fire apparatus access roads shall not exceed 10 percent in grade except as approved by the fire chief. Loading. Maintain fire apparatus access road design as per Appendix D of the 2012 Arkansas Fire Prevention Code Vol. 1 Section D102.1 Access and loading. Facilities, buildings or portions of buildings hereafter constructed shall be accessible to fire department apparatus by way of an approved fire apparatus access road with an asphalt, concrete or other approved driving surface capable of supporting the imposed load of fire apparatus weighing at least 75,000 pounds. Dead Ends. Maintain fire apparatus access roads at dead end locations as per Appendix D of the 2012 Arkansas Fire Prevention Code Vol. 1 Section D103.4 Dead Ends. Dead-end fire apparatus access roads in excess of 150 feet shall be provided with width and turnaround provisions in accordance with Table D103.4. Requirements for Dead-end fire apparatus access roads. Gates. Maintain fire apparatus access road gates as per Appendix D of the 2012 Arkansas Fire Prevention Code Vol. 1 Section D103.5 Fire apparatus access road gates. Gates securing the fire apparatus access roads shall comply with all of the following criteria: 1. Minimum gate width shall be 20 feet. 2. Gates shall be of swinging or sliding type. 3. Construction of gates shall be of material that allow manual operation by one person. 4. Gate components shall be maintained in an operable condition at all times and replaces or repaired when defective. 5. Electric gates shall be equipped with a means of opening the gate by fire department personnel for emergency access. Emergency opening devices shall be approved by the fire code official. 6. Manual opening gates shall not be locked with a padlock or chain and padlock unless they are capable of being opened by means of forcible entry tools or when a key box containing the keys to the lock is installed at the gate location. 7. Locking device specifications shall be submitted for approval by the fire code official 8. Electric gate operators, where provided, shall be listed in accordance with UL 325. 9. Gates, intended for automatic operation shall be designed, constructed and installed to comply with requirements of ASTM F 2200. One- or Two -Family Residential Developments. There are going to be over 30 houses and code requires two separate access roads, need to connect the roads inside the housing development. As per Appendix D, Section D107.1 of the Arkansas Fire Prevention Code Vol. 1, One- or Two -Family dwelling residential developments. Developments of one- or two-family dwellings where the number of dwelling units -560Z 'OZ AeW 'AL3psaupaM uo _}ejs 01(anoge pajou se uoljewiolui leuo11ippe ay1 apnloul o}) ueld/}eld fijeuiwllaid paslnaJ a jo saldoo (t,) inol IiwgnS :Ueld/jEld paslnab }uawwoo ON :a easpue-1 IuawwoO ON :apoo ulpl!n8 :Vivo -jeld aqj uo pue aoueansse jo lllq ay} ui SIMI aano}}al Ile pue }ueld jajemalsem 'slieal 'seaje uowwoo 'SAeMUaaj610aoueuaIulew JOI apinoad '£ 'MGIAaa s�jo/A ollgnd aol sueld u6lsap aajema}sem pue Ja}eM apinoad -Z wa}sAs juawjeaJ} aajennajseM COI lenadde g1IeaH jo juawpedaa sesue�JV apinad 'I, uluueld }unoo 139AIGOW }uawwoo ON :uoi}eaaoa�l pue seed l,-50l,o algelaad se slueJp/(H aiij jo uoijngpjsia pue aagwnN -(L5L£-9I,6-I.05 sapoq�j Auol -Ideo) aogo s,legsjelN aal j Noo�J 9I:41-1 ay} pue (5VZ 6-LL£-I.05 Ilnl laiued) JGIeM sesueW lealuao 4l!m uoljounfuoo ui 'S01,0 — 1,0l,o uolJoaS 'apoC) uoiJuanaJd aii.1 sesue)lad Z4OZ ayl jo 0 xipueddd aad se s4ueapAH aal=I 81s30-1 •s4ueap H aJld -leiogo apoo aig aqj Aq paulwia}ap se 'juawdolanap ajnjnj qpm joauuoo Ilp speoi ssaooe snjejedde aril ssalun paseajoul aq jou llegs pea ssaooe snjeaedde aall al6uls a uo spun buillemp jo aagwnu aul -Z •paalnbaj aq jou (legs suoijowip ON woaj ssaooe 'apoo aalJ sesueNJy ay} 10 £' I.'£-£06 Jo Z' V£-£06 T V£'£06 u0110as ql!m aouepa000e ui we4sAs aaplupds oijewolne panoidde ue y}inn Inog6nayl paddlnba aje spn 6uillamp le pue pea ssaooe snjeaedde ajil alenud ao oilgnd al6uis a uo s;lun Bulllemp p£ uey4 ajow aie aJ941 aaayM - I, :suoijdaox3 ,£,ti01.4 uoijoaS jo sjuawaalnbaa aqj jaaw llegs pue 'spec ssaooe snjeaedde W11 panadde pue ajejedas ON qj!M papinoid aq llegs O£ spaeoxe oTgva ggdep oq g4pTA -4oT mmmTxem aq-4 moat aOueTavA •S •840T 8be4u0a9-8Tgnop AOTTe 04 90ueTa2A y •ma-4GAS uoT4eTnoaio ueTaIsaped e4eua94TE uQ AOTTe 04 aoueTseA •£ •g.4bueT Des-ap-TnD mnmTxem aq4 moag aoueTavA •Z •peog STuex Sol sguameAoad= -4eaa-4s Aaepunoq jo spaepuegs peonpea Qo3 aoueTavA T Qaaismi a sdzAIKM/SSOMFiIHVA ZO • zv : s0vul SIISM30 Tz :ioraSSIa oximctIa pauoz qou/z-g :DKIMOZ 49e9 avOUTT 000'81, :ILZZHILS M3M "La SET : SZOZ a0 u2mlom 89209 V £T£ :Fi32N £ZZZL UY It XDOU OT44T7 OTOMTO buTTgeg bZ 884VTOOSSY pus sa8gva-e4Tgm IdNaNIJMS TTZZL Hy "Noo'd aT4,4T'I SO£ e4TnS •aa as-4ueo 9AT-4noexS T080T •ouI 'suoT.4veouul pagsveTun peog aeoaO 4nuTVM 30 49ea 4693 OOT'T ATegemTxoadde 'peog OmQbuiTsng 90 Opts gPQoa pue peog sTueg ;o OPTS g44OS :NOIIV007 4VTd AXVUT=Taad - (II Osega) 864e4sa 488aDuaaa :EKWH ZO£T-S 'ON Raid z : • ON HSSI TOO? 'SZ Aaenuer January 25, 2001 SUBDIVISION ITEM NO.: 2 (Cont. A. PROPOSAL: FILE NO.: S-1302 The applicant proposes to subdivide 313.37 acres along the south side of Kanis Road into 135 lots for single-family residential development. The property is located outside the Little Rock city limits, with approximately two-thirds of the property being within the City's Extraterritorial jurisdiction (zoned R-2) and the remainder in Pulaski County's jurisdiction (not zoned). - The applicant is proposing approximately 48,000 linear feet of new streets within the subdivision, which will be constructed to City standards, and maintained by the County. The applicant proposes to final plat the property in the following phases: Phase 1 - All of Ferncrest Drive - Lots 18-23, 72-82 and 121-124 Phase 2 - Lots 50-71 and 108-120 Phase 3 - Lots 1-17 Phase 4 - Lots 24-31, 83-94, 97-101 and 125-133 Phase 5 - Lots 46-49 and 106-107 Phase 6 - Lots 32-45, 95-96, 102-105 and 134-135 The applicant is requesting the following variances associated with the preliminary plat: 1. Variance for reduced standards of boundary street improvements for Kanis Road. 2. Variance from the maximum cul-de-sac length (Fletcher Creek Cove and Coldwater Canyon). 3. Variance to allow on alternate pedestrian circulation system (pedestrian paths). 4. Variance to allow double -frontage lots (Lots 1-8, 33-46 and 102-104). 5. Variance from the maximum lot width to depth ratio (Lot 22, 115-116 and 134-135). The proposed plat also shows several lakes within the subdivision. The applicant has noted that the lakes and dams will be maintained by the property owner's association. B. EXISTING CONDITIONS: The property is undeveloped with varying degrees of slope. A portion of the property is wooded, with a portion being pastureland. The general area contains single-family residences (including manufactured homes) on large lots along Kanis 2 January 25, 2001 SUBDIVISION ITEM NO.: 2 (Cont.) FILE NO.: S-1302 and Burlingame Roads. Ferncrest Estates - Phase I is located to the south across Burlingame Road. C. NEIGHBORHOOD COM MTS: As of this writing, staff has received no comment from nearby property owners. There was no established neighborhood association to notify. D. ENGINEERING COMMENTS: PUBLIC WORKS CONDITIONS: 1. Kanis Road is classified on the Master Street Plan as a minor arterial, dedication of right-of-way to 45 feet from centerline is required. 2. Burlingame Road is classified on the Master Street Plan as a principal arterial, dedication of right-of-way to 55 feet from centerline is required. 3. Construct one-half street improvements to Kanis consisting of widening of the eastbound lane to 11 feet, 4-foot paved shoulder, and open ditch. Also extend culverts. 4. Left turn lane at Ferncrest Drive intersections on Kanis and Burlingame Roads to be 150 feet stacking and 150 feet taper. 5. Investigate and engineer for safety any sight distance problems at the above mentioned intersections. Relocate entrance on Kanis Road to nearby vertical crest. 6. Lot 95 is bounded by a hairpin curve. Redesign by locating curve approximately 250 feet to the east and provide 3-way stop for connecting cul-de-sac. 7. Streets C and F exceed maximum cul-de-sac length. Redesign so that only Street C is in exceedence. Continue C along path corridor to F and terminate at Lot 116. Terminate original F at Lot 121, or request waiver. 8. The three upper lakes are not off -set from the stream and therefore violate the 25-foot stream buffer provisions on Land Alteration Ordinance, clarify tree preservation issues, and justify any variance in buffer area requested. 9. A Sketch Grading and Drainage Plan is required prior to subcommittee hearing, or no later than 5 days before Planning Commission hearing. 10. Contact the ADEQ for approval prior to start of work. 11. Contact the USACE-LRD for approval prior to start of 3 January 25, 2001 SUBDIVISION ITEM NO.: 2 (Cont. FILE NO.: S-1302 work. 12. Stormwater detention ordinance applies to this property. 13. Easements for proposed stormwater detention facilities are required. 14. Easements shown for proposed storm drainage are required. 15. Pedestrian paths must be contained within easements, must avoid trees, and be handicap accessible as much as practicable. 16. General notes incorrectly state property is within corporate city limits. 17. Sidewalk on residential streets will be required or request waiver, or expand the circulation system of paths to accommodate the equivalent usage expected of sidewalks. 18. Stipulate what responsible entity will maintain the lakes and dams. 19. Name all streets. 20. Supply horizontal curve data for all streets. E. UTILITIES AND FIRE DEPARTMENT/COUNTY PLANNING: Wastewater: Outside service boundary, no comment. Entergy: No Comment received. ARKLA: No Comment received. Southwestern Bell: No Comment received. Water: 1) This area must ultimately be served from two pressure systems due to the elevation difference (400-650 msl), 2) Service from the Colonel Glenn system will require significant off -site improvements including piping, pumping, and storage, 3) The West Markham system cannot currently serve above elevation 570 due to low pressure, 4) Service from the West Markham system will require significant off -site improvements including piping and pumping, 5) The Highland Ridge system cannot serve below elevation 490 due to high pressure, 6) Service from the Highland Ridge system will require significant off -site improvements including piping, pumping, and storage, 7) Acreage charges of $300 and $600 per acre apply, 8) All hydraulic recommendations are subject to the upcoming "Masterplan" study. 4 January 25,.2001 SUBDIVISION ITEM NO.: 2 (Cont. FILE NO.: S-1302 Fire Department: Place fire hydrants per code. Contact Dennis Free at 918-3752 for details. County Planning: See attached letter dated December 18, 2000 for Pulaski County requirements. CATA: Site is not on a dedicated bus route and has no effect on bus radius, turnout and route. F. ISSUES/TECHNICAL/DESIGN: Planning Division: No Comment. Landscape Issues: No Comment. G. SUBDIVISION COMMITTEE COMMENT: (JANUARY 4, 2001) Wayne Richie and Tim Daters were present, representing the application. Staff briefly described the proposed preliminary plat and noted several additional items which needed to be shown on the plat. The variance requests and Public Works requirements were briefly discussed. Mr. Richie noted that when he purchased the property he agreed to preserve the tree canopy along Kanis Road. Public Works staff noted that additional improvements to Kanis Road would be required, including a 4 foot paved shoulder and additional lane width. This issue was briefly discussed. Public Works staff also noted that additional pedestrian paths or sidewalks needed to be provided to improve the interior connectivity within the subdivision. Jim Narey, of Pulaski County Planning and Development, noted that street designs for all streets were needed. Jim Lawson, Director of Planning and Development, noted that all street designs should be approved by county planning. 5 January 25, t001 SUBDIVISION ITEM NO.: 2 (Cont. The Water Works requirements discussed. Julian Brown, of that he is working with the system. FILE NO.: S-1302 and water service issues were Little Rock Water Works, noted developer on the water service After the discussion, the Committee forwarded the preliminary plat to the full Commission for final action. H. ANALYSIS: The applicant submitted a revised preliminary plat drawing to staff on January 10, 2001. The revised plat addresses some of the issues as raised by staff and the Subdivision Committee. Although the applicant has submitted a phasing plan for the subdivision, a revised plat must be submitted showing the phase lines and how the temporary termination of the new streets will be dealt with. As noted in paragraph A., the applicant is requesting a variance to allow double -frontage lots (Lots 1-8, 33-46, 102-104) and a variance from the maximum lot width to depth ratio for Lot 22, 115-116 and 134-135. Staff supports these variances as requested, given the steep terrain and configuration of the property. Also noted in paragraph A. of this report, the applicant is requesting a variance for reduced standards of boundary street improvements for Ranis Road, a variance from the maximum cul-de-sac length for two (2) streets and a variance to allow an alternate pedestrian circulation system (pedestrian paths). Public Works will make recommendations or these variances at the public hearing. The maximum length allowed by ordinance for a cul-de-sac street is 750 linear feet. The variance is requested to allow the following cul-de-sac lengths: • Fletcher Creek Cove - approximately 1,700 linear feet • Coldwater Canyon - approximately 1,100 linear feet The applicant notes that the steep terrain dictates the proposed cul-de-sac lengths and locations. Given the large lot sizes proposed, the cul-de-sacs will each serve a minimal amount of lots. 2 January 25, 2001 SUBDIVISION ITEM NO.: 2 (Cont.) FILE NO.: 5-1302 As noted above, the applicant is requesting a variance to allow an alternate pedestrian circulation system. A concrete sidewalk is proposed along the entire length of Ferncrest Drive, with pedestrian paths located throughout portions of the subdivision. The applicant has noted that easements for the paths will be provided. Public Works has noted that additional paths or sidewalks are needed throughout the subdivision to provide more internal connectivity. Copies of the revised preliminary plat drawing have been forwarded to the City of Little Rock Public Works Department and the Pulaski County Department of Planning and Development. Staff anticipates that both of these agencies continue to have concerns regarding certain plat issues that need to be addressed by the applicant. The applicant has informed staff that he will work with these agencies to resolve all outstanding issues prior to the public hearing. Staff has informed these agencies to be prepared to present any outstanding issues/concerns to the Planning Commission at the public hearing. The applicant has also noted that he is continuing to work with the Little Rock Water Works Department on a definite water service plan for the property. Staff has requested that a representative from Little Rock Water Works be at the public hearing to address any questions from the Commission. According to Section 31-232(c): "Lots served by a public water system and proposed to be served by a septic tank system must submit at the time of preliminary plat filing a written certification of approval by the state department of health. The lot sizes allowed by this certification shall be indicated on the plat." The applicant wishes to wait until after preliminary plat approval for submittal of this information. Staff can support this concept with the following conditions: 1. No site work (clearing/grading) until the written certification is received by staff. 2. No final platting until the written certification is received. 7 January 29, 2001 SUBDIVISION ITEM NO.: 2 (Cont.) FILE NO.: S-1302 Although staff has no problem with the concept of a single family subdivision at this location, several outstanding issues have not been addressed by the applicant (as of this writing). The outstanding issues include (but are not limited to) the following: 1. Construction of Kanis Road 2. Radii for internal streets 3. Additional interior pedestrian paths/sidewalks 4. Waiver/variance requests S. Water service plan 6. Maintenance of traffic circle 7. Pulaski County Planning issues With resolution of all the outstanding issues, staff supports the single family preliminary plat. I. STAFF RECOMMENDATIONS: Staff recommends approval of the preliminary plat subject to the following conditions: 1.Compliance with the requirements as noted in paragraphs D and E of this report. 2.Staff recommends approval of the variances for double - frontage lots and maximum lot width to depth ratio, as noted in paragraph A. of this report. 3. Public Works will make a recommendation on the additional variances at the public hearing. 4.A revised preliminary plat must be submitted with the proposed phases shown and any additional notes as required by Public Works and Pulaski County Planning. 5.No site work (clearing/grading) or final plat until staff obtains written certification of approval for the septic tank system from the state department of health. PLANNING COMMISSION ACTION: (JANUARY 25, 2001) Tim Daters and Wayne Richie were present, representing the application. Staff briefly described the proposed preliminary plat with a recommendation of approval with conditions. There were no objectors present. Chairman Downing asked to hear from the Public Works Department. 8 January 25, 2001 SUBDIVISION ITEM NO.: 2 (Cont.) FILE NO.: S-1302 Bob Turner, Director of Public Works, described the plat and noted that Public Works supported the plat. He noted that he supported the construction of Kanis Road to reduced standards, which would include two 11-foot lanes and a 4-foot aggregate shoulder. He noted that the tree canopy over Kanis Road would be retained. He also noted that the subdivision would have only one access point from Kanis Road and one from Burlingame Road, and that the applicant would dedicate the right-of-way for Burlingame Road even though it was outside the City's jurisdiction. It was also noted that a left turn lane would be constructed on Kanis Road. Mr. Turner stated that Public Works supported the variances for cul-de-sac length, construction of Kanis Road to reduced standards and the alternate pedestrian circulation system. Julian Brown, of Little Rock Water Works, noted that he had been working with the applicant regarding this project. He noted that the water service to this development would be paid for entirely by the developer and not Little Rock Water Works. He noted that at the time this developer made improvements to water system, the Water Works would probably do additional upgrades in the system to serve future growth in the general area. Commissioner Nunnley asked about acreage charges. Mr. Brown stated that acreage charges were fees above and beyond meter charges used to reimburse the Water Works for storage tanks and pump stations and that the charges were one-time fees. Commissioner Berry asked if the acreage charges would cover all the improvements made to the water system to serve this development. Mr. Brown noted that all the improvements to serve this development would be paid for by the developer and explained that the final plan would need to be in place in order to determine the exact fees. Jim Narey, of Pulaski County Planning, noted that his department had also been working with the applicant. He stated that the applicant was well on the way to addressing the County issues. Tim Daters noted that he was present to represent the application and answer any questions. Commissioner Faust asked about sidewalks. Mr. Daters explained that there would be a five (5)-foot sidewalk along the entire length of Ferncrest Drive, with a series of pedestrian paths to 9 January 25, 2001 SUBDIVISION ITEM NO.: 2 (Cont.) FILE NO.: S-1302 provide internal circulation within the subdivision. He noted that 3,100 linear feet of pedestrian paths had been added to the plat since the Subdivision Committee meeting and pointed them out to the Commission. Commissioner Earnest asked about the five (5) acre subdivision rule and where this standard originated from. Stephen Giles, City Attorney, noted that the five (5) acre rule was a city standard. Mr. Turner noted that five (5) acre subdivisions are not subject to City Ordinance development standards. Commissioner Berry asked about the City's policy of extending water service outside the city limits. Mr. Giles responded that property owners must sign a pre -annexation agreement in order to receive city water service. Commissioner Nunnley asked if the Wildwood development had signed a pre -annexation agreement. Mr. Brown stated that they did sign an agreement. Mr. Daters noted that a pre -annexation agreement form for this property had been submitted to the City. This issue was briefly discussed. Mr. Brown noted that other property owners in this area had signed pre -annexation agreements. Commissioner Berry questioned that the city water charges for this development had not been determined. Mr. Daters stated that the developer would pay for all of the improvements for water service to this property. Commissioner Rahman commented that the Little Rock water works had a solid past history in the area of acreage charges and fees. The issue was briefly discussed. Chairman Downing made a very brief comment regarding Kanis Road. Commissioner Lowry asked if Pulaski County Planning was comfortable with the preliminary plat. Mr. Narey stated that his office had not had time to review the revised plat, but was comfortable that all the county issues would be worked out. There was a motion to approve the preliminary plat as recommended by staff to include approval of the variance requests. The motion passed by a vote of 10 ayes, 0 nays and 1 absent. 10 17 May 2015 City of Little Rock Attn: Ms. Donna James Subdivision Administrator 723 West Markham Little Rock, Arkansas 72201 Re: Annotation and Response Letter for "The Trails" Subdivision Long -Form PD-R located on the South side of Kanis Road between the Chenal Downs Subdivision and Walnut Grove Road, Little Rock, Arkansas Donna, We appreciate this opportunity to submit the following annotations and responses to the City of Little Rock's and Pulaski County's (also all utility and fire department) review comments for the above named project otherwise known as "The Trails". Please see the review comments and corresponding annotations and comments below: Planning Staff Comments: 1. Provide notification of the property owners located within 200-feet of the development including the certified abstract list, notice form with affidavit executed and proof of mailing. The notice must be mailed no later than May 20, 2015. The Office of Planning and Development must receive the proof of notice no later than May 29, 2015. Concur. Will Provide. 2. Provide details of any proposed signage. Will there be a subdivision identification sign? Provide the location, total height and total area. Concur. Will Provide. 3. Are interior fences proposed with the new construction or by the future homeowners? Include a note on the site plan including the total height and construction material to allow fencing to occur. Provide details of any perimeter fencing. Yes. Concur. WIII Provide note on site plan. 4. The plan as submitted creates streets with lots in excess of 30 homes. The streets must be looped to eliminate this conflict with the Arkansas Fire Code. Will concur with State Fire Marshal's office and West Pulaski County Fire Chief's comments pertaining to this. 5. Are accessory structures allowed, including outbuildings and swimming pools as a part of the Bill of Assurance? If these are desired include a note on the proposed site plan to allow accessory structures per the R-2, Single-family zoning district. Yes. Concur. Will provide in Bill of Assurance. 6. Provide the proposed square footages of the homes. Provide the proposed construction materials. Provide the maximum building height and the number of stories of the proposed structures. Concur. Will Provide. 7. A minimum of ten to fifteen percent of the gross planned residential district area shall be designated as common usable open space and single-family, duplex, zero -lot -line and townhouse development shall have a minimum of five hundred square feet of usable private open space per unit. Indicate the total common usable open space and the total usable private open space provided within the development. Concur. Will comply. 8. Will the development be constructed in multiple phases or in a single phase? Provide the proposed phasing plan. Multiple Phases. VarianceNVaivers: None requested. Public Works Conditions: 1. Kanis Road is classified on the Master Street Plan as a minor arterial. A dedication of right-of-way 45 feet from centerline will be required. Understood — will request waiver of ROW dedication due to the designation of this as a "Scenic Byway" via the tree cover canopy along this stretch of Kanis Road. 2. With site development, provide design of street conforming to the Master Street Plan. Construct one- half street improvement to Kanis Road with planned development. Kanis Road should be improved with pavement provided to 11 feet from centerline and a 4 feet gravel shoulder. At the proposed street intersections at least 36 feet of asphalt should be provided with striping for a left turn lane. Paving should be provided for lane shifts and striping to meet AASHTO standards could may extend beyond the property boundary. Concur. Will provide upgrades where existing grades allow without disturbing trees along Kanis Road that comprise part of the tree cover canopy along Kanis. Please see specific locations denoted (along with proposed phasing) on the plat. Also, please see the attached photos with associated notationstexplanations. 3. Storm water detention ordinance applies to this property. Show the proposed location for stormwater detention facilities on the plan. Concur. Will comply. 4. If disturbed area is 1 or more acres, obtain a NPDES storm water permit from the Arkansas Department of Environmental Quality prior to the start of construction. Concur. Will provide. 5. Kanis Road is on the Master Bike Plan. If bike lanes are desired per the Master Bike Plan and MUTCD standards, the bike lanes should be 6 feet wide measured from the back of curb and provided on both sides of the proposed street. The total street section would be 34 feet wide from back of curb to back of curb. The bike lanes should continue on Kanis Road east and west of the proposed intersections to the side property lines. The paved lane should be 5 feet wide with striping and takes the place of the 4 feet gravel shoulder in these areas. Concur. Will comply where bike lanes are provided. 6. The provided typical road cross section is not accurate and widths are confusing. Concur. Will clarify cross sections. 7. Local streets centerline grade cannot exceed 15% without approval of a variance to the Master Street Plan. Local streets centerline grade cannot exceed 5% at the first 30 feet of an intersection. Concur. Will request variance as required to exceed this maximum slope. 8. • Floodplain is shown on the subject property. Contact Pulaski County Road and Bridge for floodplain regulations and conditions. Concur. Will comply. 9. Alteration of the water course will require approval from the Little Rock District of the US Army Corps of Engineers prior to start of work. Concur. No water courses are being altered. 10. Street Improvement plans shall include signage and striping. Public Works must approve completed plans prior to construction. Concur. Will comply. 11. In accordance with Section 31-176, floodway areas must be shown as floodway easements or be dedicated to the public. In addition, a 25 foot wide drainage and access easement is required adjacent to the floodway boundary. Concur. Will provide additional drainage and access easements as noted. 12. Street lights are required by Section 31-403 of the LR code. Provide plans for approval to Traffic Engineering. Street lights must be installed prior to platting/certificate of occupancy. Contact Traffic Engineering, Greg Simmons, gsimmions@littlerock.org or 501.379.1813 for more information. Concur. Will comply and street lights are being provided as part of this project. 13. Per the Master Street Plan, parking is restricted to one side of the street on a 24 feet wide street. Show on the plan now and on the final plat and bill of assurance, the area along the street where parking is allowed. Concur. No 24 feet wide streets are included in the subdivision. 14. Damage to public and private property due to hauling operations or operation of construction related equipment from a nearby construction site shall be repaired by the responsible party prior to issuance of a certificate of occupancy. Concur. Will comply. 15. A minimum undisturbed strip 25 feet wide except for reasonable access shall be provided along each side of streams having a 10 year storm >150 cfs. The undisturbed strip should be measured from the top of the bank. Concur. Will comply. 16. The minimum finish floor elevation as required by Pulaski County is required to be shown on plat and grading plans. Concur. Will provide on lots that are affected. 17. Plans of all work in right-of-way shall be submitted for approval prior to start of work. Concur. Will comply. 18. Provide a letter prepared by a registered engineer certifying the sight distance at the Kanis Road intersection(s) comply with 2004 AASHTO Green Book standards. Concur. Will provide. 19. Repair or replace any curb and gutter or sidewalk that is damaged in the public right-of-way prior to occupancy. Concur. Will comply. 20. Street names and street naming conventions must be approved by Public Works. Contact Glenn Haley at (501) 371-4537. The street names Ridge Trail, Sunset Trail, Fern Trail, and Summit Trail are duplicates. Concur. Will coordinate and correct. 21. The proposed traffic circle should be constructed per AASHTO and FHWA standards with bike lanes and splitter islands. Contact Nat Banihatti in Traffic Engineering at 501-379-1818 for additional information. Concur. Will comply. 22. Traffic calming devices are required for long straight streets to discourage speeding. Traffic circles or round -about are suggested at regular intervals and at main intersections. Contact Travis Herbner, Traffic Engineering. at 379-1805 for additional info. Concur. Will provide as required. 23. The accel and decel lanes on Kanis Road should not be constructed. Concur. Will be deleted from project. 24. Emergency access should be provided for area of subdivisions with 30 for more homes and only 1 access. Will concur with State Fire Marshal's office and West Pulaski County Fire Chief's comments pertaining to this. 25. Walnut Grove Road is classified on the Master Street Plan as a principal arterial. Dedication of right- of-way to 55 feet from centerline will be required. Per the Master Street Plan at the intersection of arterial/arterial intersections, an additional 10 feet of right-of-way should be dedicated for a right turn lane for a length of 250 feet. The total width of dedication is 65 feet. Concur. Will dedicate additional Right -Of -Way but are requesting waiver for half street improvements as this is a long term upgrade for Walnut Grove Road. 26. Per the Master Street Plan at arterial/arterial intersections, a 100 feet radial dedication of right-of-way is required at the intersection of Walnut Grove Rd and Kanis Rd. Concur. Will dedicate Right -Of - Way as required. 27. Sidewalk should be installed along Summit Trail south of traffic circle. The sidewalk should be on the outside of the circle portion of Summit Trail. We are providing trails throughout the subdivision in lieu of sidewalks. 28. The minimum stopping sight distance of 155 feet or latest AASHTO policy on Geometric Design Manual and 150 feet minimum horizontal radius at centerline. Concur. Will comply and request variance if required regarding stopping distance and sight distance. Utilities and Fire Department/County Planning: Wastewater: Outside the service boundary, no comment. Noted. Entergy: Entergy does not object to this proposal. A single phase power line exists on the western side of the property, but nowhere else. Service to the proposed lots will be installed and provided along the front lot lines along the new streets. Contact Entergy in advance regarding future service requirements and additional facilities location(s) as this development will require extensive work to install facilities to the 299 proposed lots. Concur. Noted. Center pint Energy: No comment received. Noted. AT & T: No comment received. Noted. Central Arkansas Water: 1. All Central Arkansas Water requirements in effect at the time of request for water service must be met. Concur. Will comply. 2. A water main extension will be needed to provide water service to this property. Concur. Will provide. 3. Please submit plans for water facilities and/or fire protection system to Central Arkansas Water for review. Plan revisions may be required after additional review. Contact Central Arkansas Water regarding procedures for installation of water facilities and/or fire service. Approval of plans by the Arkansas Department of Health Engineering Division and the Little Rock Fire Department is required. Concur. Will comply. 4. This development will have minor impact on the existing water distribution system. Proposed water facilities will be sized to provide adequate pressure and fire protection. Concur. Will comply. 5. If there are facilities that need to be adjusted and/or relocated, contact Central Arkansas Water. That work would be done at the expense of the developer. Concur. Will comply. 6. Additional fire hydrant(s) will be required. Contact the Little Rock Fire Department to obtain information regarding the required placement of the hydrant(s) and contact Central Arkansas Water regarding procedures for installation of the hydrant(s). Concur. Will provide. 7. A Capital Investment Charge based on the size of meter connection(s) will apply to this project in addition to normal charges. This fee will apply to all connections including metered connections off the private fire system. Concur. Noted. Fire i?egartment: Maintain Aggess. Fire Hydrants. Maintain fire apparatus access roads at fire hydrant locations as per Appendix D of the 2012 Arkansas Fire Prevention Code Vol. 1 Section D103.1 Access road width with a hydrant. Where a fire hydrant is located on a fire apparatus access road, the minimum road width shall be 26 feet, exclusive of shoulders. Concur. Will comply. Grade. Maintain fire apparatus access roads as per Appendix D of the 2012 Arkansas Fire Prevention Code Vol. 1 Section D103.2 Grade. Fire apparatus access roads shall not exceed 10 percent in grade except as approved by the fire chief. Concur. Will comply. Loading. Maintain fire apparatus access road design as per Appendix D of the 2012 Arkansas Fire Prevention Code Vol. 1 Section D102.1 Access and loading. Facilities, buildings or portions of buildings hereafter constructed shall be accessible to fire department apparatus by way of an approved fire apparatus access road with an asphalt, concrete or other approved driving surface capable of supporting the imposed load of fire apparatus weighing at least 75,000 pounds. Concur. Will comply. Dead Ends. Maintain fire apparatus access roads at dead end locations as per Appendix D of the 2012 Arkansas Fire Prevention Code Vol. 1 Section D103.4 Dead Ends. Dead-end fire apparatus access roads in excess of 150 feet shall be provided with width and turnaround provisions in accordance with Table D103.4. Requirements for Dead-end fire apparatus access roads. Concur. Will provide. Gates. Maintain fire apparatus access road gates as per Appendix D of the 2012 Arkansas Fire Prevention Code Vol. 1 Section D103.5 Fire apparatus access road gates. Gates securing the fire apparatus access roads shall comply with all of the following criteria: 1. Minimum gate width shall be 20 feet. Concur. Will comply. 2. Gates shall be of swinging or sliding type. Concur. Will comply. 3. Construction of gates shall be of material that allow manual operation by one person. Concur. Will comply. 4. Gate components shall be maintained in an operable condition at all times and replaces or repaired when defective. Concur. Will comply. 5. Electric gates shall be equipped with a means of opening the gate by fire department personnel for emergency access. Emergency opening devices shall be approved by the fire code official. Concur. Will comply. 6. Manual opening gates shall not be locked with a padlock or chain and padlock unless they are capable of being opened by means of forcible entry tools or when a key box containing the keys to the lock is installed at the gate location. Concur. Will comply. 7. Locking device specifications shall be submitted for approval by the fire code official Concur. Will comply. 8. Electric gate operators, where provided, shall be listed in accordance with UL 325. Concur. Will comply. 9. Gates, intended for automatic operation shall be designed, constructed and installed to comply with requirements of ASTM F 2200. Concur. Will comply. One- or Two -Family Residential Deveio ments. There are going to be over 30 houses and code requires two separate access roads, need to connect the roads inside the housing development. As per Appendix D, Section 0107.1 of the Arkansas Fire Prevention Code Vol. 1, One- or Two -Family dwelling residential developments. Developments of one- or two-family dwellings where the number of dwelling units exceeds 30 shall be provided with two separate and approved fire apparatus access roads, and shall meet the requirements of Section D104.3. Will concur with State Fire Marshal's office and West Pulaski County Fire Chief's comments pertaining to this Exceptions: 1. Where there are more than 30 dwelling units on a single public or private fire apparatus access road and al dwelling units are equipped throughout with an approved automatic sprinkler system in accordance with Section 903.3.1.1, 903.3.1.2 or 903.3.1.3 of the Arkansas Fire Code, access from two directions shall not be required. 2. The number of dwelling units on a single fire apparatus access road shall not be increased unless fire apparatus access roads will connect with future development, as determined by the fire code official. Fire Hydrants. Locate Fire Hydrants as per Appendix C of the 2012 Arkansas Fire Prevention Code. Section C101 — C105, in conjunction with Central Arkansas Water (Daniel Tull 501-377-1245) and the Little Rock Fire Marshal's Office (Capt. Tony Rhodes 501-918-3757). Number and Distribution of Fire Hydrants as per Table C105.1. Concur. Will comply. Parks and Recreation: No comment received. Noted. County Plannina: 1. Provide Bill of Assurance. Concur. Will comply. 2. Show State Plane coordinates for two corners. Concur. Will comply. 3. Label index contour so contour interval can be determined. Concur. Will comply. 4. Provide zoning for existing and adjacent parcels. Concur. Will comply. 5. Lot size is smaller than 6,000 square feet allowed by Pulaski County Subdivision and Development Code. Show lot dimensions and bearings on all lots. Concur. Will comply. 6. Show each lot size in acres and square feet. Concur. Will comply. 7. Provide source of water. Concur. Will comply. 8. Provide Arkansas Department of Health approval for wastewater treatment system. Concur. Will comply. 9. Provide approval from the Volunteer Fire Department. Concur. Will comply. 10. Provide profile for all streets. Concur. Will comply. 11. Label all street centerlines. Concur. Will comply. 12. Provide storm drainage plan. Concur. Will comply. 13. Provide effective FEMA flood panel number. Concur. Will comply. 14. Provide Pulaski County preliminary certificate of approval, not final plat approval. Concur. Will comply. 15. Street names in proposed subdivision are identical to several streets within the City of Little Rock corporate limits. Rename streets as needed to avoid conflicts. Concur. Will comply. 16. Provide full set of construction plans for all streets once PD-R is approved by the City of Little Rock Board of Directors. Concur. Will comply. 17. Front, rear and side setbacks do not comply with Pulaski County Subdivision and Development Code standards. 25-foot front and rear setback is required with an 8-foot side yard setback. Please note that these are being altered as part of the PD-R. 18. Provide SWPPP for Pulaski County review. Concur. Will comply. 19. Pay $132.00 review fee. Concur. Will comply. Additional Comments — 1. Provide water and wastewater design plans for Public Works review. Concur. Will comply. 2. Provide for maintenance of greenways, common areas, trails, wastewater plant and all leftover tracts in the bill of assurance and on the plat. Concur. Will comply. 3. Obtain appropriate road cut permits from Pulaski County Public Works for Kanis Road. Concur. Will comply. 4. Large Lot #1 at east end of the subdivision should be labeled Lot 6 immediately to the west should be labeled Lot 7. Concur. Will comply. 5. Provide turnarounds at maximum 9-foot intervals for all cul-de-sac streets. Need further clarification. 6. Provide drainage easement as needed between lots. Concur. Will comply. 7. Subject to approval of the PD-R zoning by the City of Little Rock, comments related to lot sizes and setbacks are not applicable. Concur. Will comply. CATA: Building Code: No Comment Noted. Planning Division: This request is located in the Burlingame Valley Planning District. The Land Use Plan shows Residential Low Density (RL) and Agricultural (A) for this property. The Residential Low Density (RL) category provides for single family homes at densities not to exceed six (6) units per acre. Such residential development is typically characterized by conventional single family homes, but may include patio or garden homes and cluster homes, provided that the density remain less than six (6) units per acre. The Agricultural category is to encourage the continuation of agricultural uses of the land. The agricultural classification also provides for a transition between rural areas and the urban fringe, where it would be appropriate to preserve existing rural land use, prior to annexation into the city. The applicant has applied for a rezoning from R-2 (Single Family District) to PDR (Planned Commercial District) to allow for the development of a single family subdivision on this site. Noted. Master Street Plan: Walnut Grove Road is a Principal Arterial and Kanis Road is a Minor Arterial on the Master Street Plan. A Principal Arterial is to serve through traffic and to connect major traffic generators or activity centers within the urbanized area. Entrances and exits should be limited to minimize negative effects of traffic and pedestrians on Walnut Grove Road since it is a Principal Arterial. A Minor Arterial provides connections to and through an urban area and their primary function is to provide short distance travel within the urbanized area. Entrances and exits should be limited to minimize negative effects of traffic and pedestrians on Kanis Road. These streets may require dedication of right-of-way and may require street improvements for entrances and exits to the site. Noted. Bicycle Plan: A Class II Bike Lanes are shown along both Colonel Glenn Road and Lawson Road. Bike Lanes provide a portion of the pavement for the sole use of bicycles. Noted. Landscape: No comment. Noted. Revised platlplan: Submit four (4) copies of a revised preliminary plat/plan (to include the additional information as noted above) to staff on Wednesday, May 20, 2015. Concur. Will comply. ITEM NO.: 19. Z- 9042 NAME: The Trails Conditional Use Permit LOCATION: located on the Southside of Kanis Road between the Chenal Downs Subdivision and Walnut Grove Road Planpino Staff Comments: 1. Provide notification of the property owners located within 200-feet of the development including the certified abstract list, notice form with affidavit executed and proof of mailing. The notice must be mailed no later than May 20, 2015. The Office of Planning and Development must receive the proof of notice no later than May 29, 2015. 2. Provided details of the proposed treatment system, who will permit (State Agency), who will be responsible for maintenance (Property Owners Association/Developer), what are the required setbacks from adjacent properties, what are the discharge requirements and/or perimeters for disposal of treated effluent. 3. Has a permit request been made to the proper permitting agencies to allow for the proposed treatment system? 4. Will the system be located above or below the ground? 5. All subdivisions shall be provided with water supply and distribution systems approved by the city and meeting the requirements of the state health department. Where a public water supply is within a reasonable distance of the subdivision, the subdivider shall install or have installed a system of water mains and connect to such supply. A connection to each lot shall be installed prior to the paving of the street, if possible. 6. Section 31-400 - All subdivisions shall be provided with a sewage collection and treatment system approved by the wastewater utility and/or the state board of health. Where a public sanitary sewer is within a reasonable distance of any point of a subdivision, the subdivider shall connect with such sewer and provide a connection to each lot. Such sanitary sewage system shall be installed prior to the installation of the street pavement. The sewage collection system shall be designed to handle the anticipated flow of sewage from within the subdivision, including development of future sections of the same subdivision and adjacent areas within the same drainage basin. Recognized engineering design criteria in accordance with the state department of health shall be used to design the system. VarianceMaivers: None requested. Pu lic Works Conditions: 1. Kanis Road is classified on the Master Street Plan as a minor arterial. A dedication of right-of-way 45 feet from centerline will be required. 2. Some floodplain is identified on the subject property. Contact Pulaski County Road and Bridge about the conditions for developing in the 100 year floodplain. Utilities and Fire Department(County Planning: Wastewater: Outside the service boundary. No comment. Enter : Entergy does not object to this proposal. A single phase power line exists on the western side of the property, but nowhere else. Service to the proposed lots will be installed and provided along the front lot lines along the new streets. Contact Entergy in advance regarding future service requirements and additional facilities location(s) as this development will require extensive work to install facilities to the 299 proposed lots. Centerooint Energy: No comment received. AT & T: No comment received. Central Arkansas Water: 1. All Central Arkansas Water requirements in effect at the time of request for water service must be met. 2. A water main extension will be needed to provide water service to this property. 3. Please submit plans for water facilities and/or fire protection system to Central Arkansas Water for review. Plan revisions may be required after additional review. Contact Central Arkansas Water regarding procedures for installation of water facilities and/or fire service. Approval of plans by the Arkansas Department of Health Engineering Division and the Little Rock Fire Department is required. 4. This development will have minor impact on the existing water distribution system. Proposed water facilities will be sized to provide adequate pressure and fire protection. 5. If there are facilities that need to be adjusted and/or relocated, contact Central Arkansas Water. That work would be done at the expense of the developer. 6. Additional fire hydrant(s) will be required. Contact the Little Rock Fire Department to obtain information regarding the required placement of the hydrant(s) and contact Central Arkansas Water regarding procedures for installation of the hydrant(s). 7. A Capital Investment Charge based on the size of meter connection(s) will apply to this project in addition to normal charges. This fee will apply to all connections including metered connections off the private fire system. Fire Department: Mal. main Access. Fire Hydrants. Maintain fire apparatus access roads at fire hydrant locations as per Appendix D of the 2012 Arkansas Fire Prevention Code Vol. 1 Section D103.1 Access road width with a hydrant. Where a fire hydrant is located on a fire apparatus access road, the minimum road width shall be 26 feet, exclusive of shoulders. Grade. Maintain fire apparatus access roads as per Appendix D of the 2012 Arkansas Fire Prevention Code Vol. 1 Section D103.2 Grade. Fire apparatus access roads shall not exceed 10 percent in grade except as approved by the fire chief. Loadina. Maintain fire apparatus access road design as per Appendix D of the 2012 Arkansas Fire Prevention Code Vol. 1 Section D102.1 Access and loading. Facilities, buildings or portions of buildings hereafter constructed shall be accessible to fire department apparatus by way of an approved fire apparatus access road with an asphalt, concrete or other approved driving surface capable of supporting the imposed load of fire apparatus weighing at least 75,000 pounds. Dead Ends. Maintain fire apparatus access roads at dead end locations as per Appendix D of the 2012 Arkansas Fire Prevention Code Vol. 1 Section D103.4 Dead Ends. Dead-end fire apparatus access roads in excess of 150 feet shall be provided with width and turnaround provisions in accordance with Table D103.4. Requirements for Dead-end fire apparatus access roads. Gates. Maintain fire apparatus access road gates as per Appendix D of the 2012 Arkansas Fire Prevention Code Vol. 1 Section D103.5 Fire apparatus access road gates. Gates securing the fire apparatus access roads shall comply with all of the following criteria: 1. Minimum gate width shall be 20 feet. 2. Gates shall be of swinging or sliding type. 3. Construction of gates shall be of material that allow manual operation by one person. 4. Gate components shall be maintained in an operable condition at all times and replaces or repaired when defective. 5. Electric gates shall be equipped with a means of opening the gate by fire department personnel for emergency access. Emergency opening devices shall be approved by the fire code official. 6. Manual opening gates shall not be locked with a padlock or chain and padlock unless they are capable of being opened by means of forcible entry tools or when a key box containing the keys to the lock is installed at the gate location. 7. Locking device specifications shall be submitted for approval by the fire code official 8. Electric gate operators, where provided, shall be listed in accordance with UL 325. 9. Gates, intended for automatic operation shall be designed, constructed and installed to comply with requirements of ASTM F 2200. n - Or Twg-Farnily Bg.�Wqnfigl Oevelogments. There are going to be over 30 houses and code requires two separate access roads, need to connect the roads inside the housing development. As per Appendix D, Section D107.1 of the Arkansas Fire Prevention Code Vol. 1, One- or Two -Family dwelling residential developments. Developments of one- or two-family dwellings where the number of dwelling units exceeds 30 shall be provided with two separate and approved fire apparatus access roads, and shall meet the requirements of Section D104.3. Exceptions: 1. Where there are more than 30 dwelling units on a single public or private fire apparatus access road and al dwelling units are equipped throughout with an approved automatic sprinkler system in accordance with Section 903.3.1.1, 903.3.1.2 or 903.3.1.3 of the Arkansas Fire Code, access from two directions shall not be required. 2. The number of dwelling units on a single fire apparatus access road shall not be increased unless fire apparatus access roads will connect with future development, as determined by the fire code official. Fire Hydrants. Locate Fire Hydrants as per Appendix C of the 2012 Arkansas Fire Prevention Code. Section C101 — C105, in conjunction with Central Arkansas Water (Daniel Tull 501-377-1245) and the Little Rock Fire Marshal's Office (Capt. Tony Rhodes 501-918-3757). Number and Distribution of Fire Hydrants as per Table C105.1. Parks and Recreation: No comment received. County Piannin,A 1. Provide Arkansas Department of Health approval for wastewater treatment system. 2. Provide water and wastewater design plans for Public Works review. 3. Provide for maintenance of greenways, common areas, trails, wastewater plant and all leftover tracts in the bill of assurance and on the plat. CATA: Building Code: No Comment Landscape: No comment. Revised plat/plan: Submit four (4) copies of a revised preliminary plat/plan (to include the additional information as noted above) to staff on Wednesday, May 20, 2015. PHILLIP LEWIS ENGINEERING, INC. Structural/Civil Design 2701 Kavanaugh Blvd, Suite 200 Little Rock, Arkansas 72205 Again, I do appreciate the opportunity to present The Trails and look forward to working hand in hand with the City of Little Rock and Pulaski County in making this unique development a reality. Sincerely, Phillip Lewis, P.E. c.501.350.9840 17 May 2015 City of Little Rock Attn: Ms. Donna James Subdivision Administrator 723 West Markham Little Rock, Arkansas 72201 Re: Annotation and Response Letter for "The Trails" Subdivision Long -Form PD-R located on the South side of Kanis Road between the Chenal Downs Subdivision and Walnut Grove Road, Little Rock, Arkansas Donna, We appreciate this opportunity to submit the following annotations and responses to the City of Little Rock's and Pulaski County's (also all utility and fire department) review comments for the above named project otherwise known as "The Trails". Please see the review comments and corresponding annotations and comments below: Plan!lino Staff Comments: Provide notification of the property owners located within 200-feet of the development including the certified abstract list, notice form with affidavit executed and proof of mailing. The notice must be mailed no later than May 20, 2015. The Office of Planning and Development must receive the proof of notice no later than May 29, 2015. Concur. Will Provide. 2. Provide details of any proposed signage. Will there be a subdivision identification sign? Provide the location, total height and total area. Concur. Will Provide. 3. Are interior fences proposed with the new construction or by the future homeowners? Include a note on the site plan including the total height and construction material to allow fencing to occur. Provide details of any perimeter fencing. Yes. Concur. Will Provide note on site plan. 4. The plan as submitted creates streets with lots in excess of 30 homes. The streets must be looped to eliminate this conflict with the Arkansas Fire Code. Will concur with State Fire Marshal's office and West Pulaski County Fire Chief's comments pertaining to this. 5. Are accessory structures allowed, including outbuildings and swimming pools as a part of the Bill of Assurance? If these are desired include a note on the proposed site plan to allow accessory structures per the R-2, Single-family zoning district. Yes. Concur. Will provide in Bill of Assurance. 6. Provide the proposed square footages of the homes. Provide the proposed construction materials. Provide the maximum building height and the number of stories of the proposed structures. Concur. Will Provide. 7. A minimum of ten to fifteen percent of the gross planned residential district area shall be designated as common usable open space and single-family, duplex, zero -lot -line and townhouse development shall have a minimum of five hundred square feet of usable private open space per unit. Indicate the total common usable open space and the total usable private open space provided within the development. Concur. Will comply. 8. Will the development be constructed in multiple phases or in a single phase? Provide the proposed phasing plan. Multiple Phases. Variance/Waivers: None requested. Public Works Conditions: 1. Kanis Road is classified on the Master Street Plan as a minor arterial. A dedication of right-of-way 45 feet from centerline will be required. Understood — will request waiver of ROW dedication due to the designation of this as a "Scenic Byway" via the tree cover canopy along this stretch of Kanis Road. 2. With site development, provide design of street conforming to the Master Street Plan. Construct one- half street improvement to Kanis Road with planned development. Kanis Road should be improved with pavement provided to 11 feet from centerline and a 4 feet gravel shoulder. At the proposed street intersections at least 36 feet of asphalt should be provided with striping for a left turn lane. Paving should be provided for lane shifts and striping to meet AASHTO standards could may extend beyond the property boundary. Concur. Will provide upgrades where existing grades allow without disturbing trees along Kanis Road that comprise part of the tree cover canopy along Kanis. Please see specific locations denoted (along with proposed phasing) on the plat. Also, please see the attached photos with associated notationstexplanations. 3. Storm water detention ordinance applies to this property. Show the proposed location for stormwater detention facilities on the plan. Concur. Will comply. 4. If disturbed area is 1 or more acres, obtain a NPDES storm water permit from the Arkansas Department of Environmental Quality prior to the start of construction. Concur. Will provide. 5. Kanis Road is on the Master Bike Plan. If bike lanes are desired per the Master Bike Plan and MUTCD standards, the bike lanes should be 6 feet wide measured from the back of curb and provided on both sides of the proposed street. The total street section would be 34 feet wide from back of curb to back of curb. The bike lanes should continue on Kanis Road east and west of the proposed intersections to the side property lines. The paved lane should be 5 feet wide with striping and takes the place of the 4 feet gravel shoulder in these areas. Concur. Will comply where bike lanes are provided. 6. The provided typical road cross section is not accurate and widths are confusing. Concur. Will clarify cross sections. 7. Local streets centerline grade cannot exceed 15% without approval of a variance to the Master Street Plan. Local streets centerline grade cannot exceed 5% at the first 30 feet of an intersection. Concur. Will request variance as required to exceed this maximum slope. 8. Floodplain is shown on the subject property. Contact Pulaski County Road and Bridge for floodplain regulations and conditions. Concur. Will comply. 9. Alteration of the water course will require approval from the Little Rock District of the US Army Corps of Engineers prior to start of work. Concur. No water courses are being altered. 10. Street Improvement plans shall include signage and striping. Public Works must approve completed plans prior to construction. Concur. Will comply. 11. In accordance with Section 31-176, floodway areas must be shown as floodway easements or be dedicated to the public. In addition, a 25 foot wide drainage and access easement is required adjacent to the floodway boundary. Concur. Will provide additional drainage and access easements as noted. 12. Street lights are required by Section 31-403 of the LR code. Provide plans for approval to Traffic Engineering. Street lights must be installed prior to platting/certificate of occupancy. Contact Traffic Engineering, Greg Simmons, gsimmions@littlerock.org or 501.379.1813 for more information. Concur. Will comply and street lights are being provided as part of this project. 13. Per the Master Street Plan, parking is restricted to one side of the street on a 24 feet wide street. Show on the plan now and on the final plat and bill of assurance, the area along the street where parking is allowed. Concur. No 24 feet wide streets are included in the subdivision. 14. Damage to public and private property due to hauling operations or operation of construction related equipment from a nearby construction site shall be repaired by the responsible party prior to issuance of a certificate of occupancy. Concur. Will comply. 15. A minimum undisturbed strip 25 feet wide except for reasonable access shall be provided along each side of streams having a 10 year storm >150 cfs. The undisturbed strip should be measured from the top of the bank. Concur. Will comply. 16. The minimum finish floor elevation as required by Pulaski County is required to be shown on plat and grading plans. Concur. Will provide on lots that are affected. 17. Plans of all work in right-of-way shall be submitted for approval prior to start of work. Concur. Will comply. 18. Provide a letter prepared by a registered engineer certifying the sight distance at the Kanis Road intersection(s) comply with 2004 AASHTO Green Book standards. Concur. Will provide. 19. Repair or replace any curb and gutter or sidewalk that is damaged in the public right-of-way prior to occupancy. Concur. Will comply. 20. Street names and street naming conventions must be approved by Public Works. Contact Glenn Haley at (501) 371-4537. The street names Ridge Trail, Sunset Trail, Fern Trail, and Summit Trail are duplicates. Concur. Will coordinate and correct. 21. The proposed traffic circle should be constructed per AASHTO and FHWA standards with bike lanes and splitter islands. Contact Nat Banihatti in Traffic Engineering at 501-379-1818 for additional information. Concur. Will comply. 22. Traffic calming devices are required for long straight streets to discourage speeding. Traffic circles or round -about are suggested at regular intervals and at main intersections. Contact Travis Herbner, Traffic Engineering. at 379-1805 for additional info. Concur. Will provide as required. 23. The accel and decel lanes on Kanis Road should not be constructed. Concur. Will be deleted from project. 24. Emergency access should be provided for area of subdivisions with 30 for more homes and only 1 access. Will concur with State Fire Marshal's office and West Pulaski County Fire Chief's comments pertaining to this. 25. Walnut Grove Road is classified on the Master Street Plan as a principal arterial. Dedication of right- of-way to 55 feet from centerline will be required. Per the Master Street Plan at the intersection of arterial/arterial intersections, an additional 10 feet of right-of-way should be dedicated for a right turn lane for a length of 250 feet. The total width of dedication is 65 feet. Concur. Will dedicate additional Right -Of -Way but are requesting waiver for half street Improvements as this is a long term upgrade for Walnut Grove Road. 26. Per the Master Street Plan at arterial/arterial intersections, a 100 feet radial dedication of right-of-way is required at the intersection of Walnut Grove Rd and Kanis Rd. Concur. Will dedicate Right -Of - Way as required. 27. Sidewalk should be installed along Summit Trail south of traffic circle. The sidewalk should be on the outside of the circle portion of Summit Trail. We are providing trails throughout the subdivision in lieu of sidewalks. 28. The minimum stopping sight distance of 155 feet or latest AASHTO policy on Geometric Design Manual and 150 feet minimum horizontal radius at centerline. Concur. Will comply and request variance if required regarding stopping distance and sight distance. Utilities and Fire Department/County Planning: Wastewater: Outside the service boundary, no comment. Noted. EnterQv: Entergy does not object to this proposal. A single phase power line exists on the western side of the property, but nowhere else. Service to the proposed lots will be installed and provided along the front lot lines along the new streets. Contact Entergy in advance regarding future service requirements and additional facilities location(s) as this development will require extensive work to install facilities to the 299 proposed lots. Concur. Noted. Centerpoint Energy_: No comment received. Noted. AT & T: No comment received. Noted. Central Arkansas Water: 1. All Central Arkansas Water requirements in effect at the time of request for water service must be met. Concur. Will comply. 2. A water main extension will be needed to provide water service to this property. Concur. Will provide. 3. Please submit plans for water facilities and/or fire protection system to Central Arkansas Water for review. Plan revisions may be required after additional review. Contact Central Arkansas Water regarding procedures for installation of water facilities and/or fire service. Approval of plans by the Arkansas Department of Health Engineering Division and the Little Rock Fire Department is required. Concur. Will comply. 4. This development will have minor impact on the existing water distribution system. Proposed water facilities will be sized to provide adequate pressure and fire protection. Concur. Will comply. 5. If there are facilities that need to be adjusted and/or relocated, contact Central Arkansas Water. That work would be done at the expense of the developer. Concur. Will comply. 6. Additional fire hydrant(s) will be required. Contact the Little Rock Fire Department to obtain information regarding the required placement of the hydrant(s) and contact Central Arkansas Water regarding procedures for installation of the hydrant(s). Concur. Will provide. 7. A Capital Investment Charge based on the size of meter connection(s) will apply to this project in addition to normal charges. This fee will apply to all connections including metered connections off the private fire system. Concur. Noted. Fire Department: Maintain Access. Fire Hydrants. Maintain fire apparatus access roads at fire hydrant locations as per Appendix D of the 2012 Arkansas Fire Prevention Code Vol. 1 Section D103.1 Access road width with a hydrant. Where a fire hydrant is located on a fire apparatus access road, the minimum road width shall be 26 feet, exclusive of shoulders. Concur. Will comply. Grade. Maintain fire apparatus access roads as per Appendix D of the 2012 Arkansas Fire Prevention Code Vol. 1 Section D103.2 Grade. Fire apparatus access roads shall not exceed 10 percent in grade except as approved by the fire chief. Concur. Will comply. Loagling. Maintain fire apparatus access road design as per Appendix D of the 2012 Arkansas Fire Prevention Code Vol. 1 Section D102.1 Access and loading. Facilities, buildings or portions of buildings hereafter constructed shall be accessible to fire department apparatus by way of an approved fire apparatus access road with an asphalt, concrete or other approved driving surface capable of supporting the imposed load of fire apparatus weighing at least 75,000 pounds. Concur. Will comply. Dead Ends. Maintain fire apparatus access roads at dead end locations as per Appendix D of the 2012 Arkansas Fire Prevention Code Vol. 1 Section D103.4 Dead Ends. Dead-end fire apparatus access roads in excess of 150 feet shall be provided with width and turnaround provisions in accordance with Table D103.4. Requirements for Dead-end fire apparatus access roads. Concur. Will provide. Gates. Maintain fire apparatus access road gates as per Appendix D of the 2012 Arkansas Fire Prevention Code Vol. 1 Section D103.5 Fire apparatus access road gates. Gates securing the fire apparatus access roads shall comply with all of the following criteria: 1. Minimum gate width shall be 20 feet. Concur. Will comply. 2. Gates shall be of swinging or sliding type. Concur. Will comply. 3. Construction of gates shall be of material that allow manual operation by one person. Concur. Will comply. 4. Gate components shall be maintained in an operable condition at all times and replaces or repaired when defective. Concur. Will comply. 5. Electric gates shall be equipped with a means of opening the gate by fire department personnel for emergency access. Emergency opening devices shall be approved by the fire code official. Concur. Will comply. 6. Manual opening gates shall not be locked with a padlock or chain and padlock unless they are capable of being opened by means of forcible entry tools or when a key box containing the keys to the lock is installed at the gate location. Concur. Will comply. 7. Locking device specifications shall be submitted for approval by the fire code official Concur. Will comply. 8. Electric gate operators, where provided, shall be listed in accordance with UL 325. Concur. Will comply. 9. Gates, intended for automatic operation shall be designed, constructed and installed to comply with requirements of ASTM F 2200. Concur. Will comply. One- or Two -Family Residential Developments. There are going to be over 30 houses and code requires two separate access roads, need to connect the roads inside the housing development. As per Appendix D, Section D107.1 of the Arkansas Fire Prevention Code Vol. 1, One- or Two -Family dwelling residential developments. Developments of one- or two-family dwellings where the number of dwelling units exceeds 30 shall be provided with two separate and approved fire apparatus access roads, and shall meet the requirements of Section D104.3. Will concur with State Fire Marshal's office and West Pulaski County Fire Chief's comments pertaining to this Exceptions: 1. Where there are more than 30 dwelling units on a single public or private fire apparatus access road and al dwelling units are equipped throughout with an approved automatic sprinkler system in accordance with Section 903.3.1.1, 903.3.1.2 or 903.3.1.3 of the Arkansas Fire Code, access from two directions shall not be required. 2. The number of dwelling units on a single fire apparatus access road shall not be increased unless fire apparatus access roads will connect with future development, as determined by the fire code official. Fire Hydrants. Locate Fire Hydrants as per Appendix C of the 2012 Arkansas Fire Prevention Code. Section C101 — C105, in conjunction with Central Arkansas Water (Daniel Tull 501-377-1245) and the Little Rock Fire Marshal's Office (Capt. Tony Rhodes 501-918-3757). Number and Distribution of Fire Hydrants as per Table C105.1. Concur. Will comply. Parks and Recreation: No comment received. Noted. County Plannina: 1. Provide Bill of Assurance. Concur. Will comply. 2. Show State Plane coordinates for two corners. Concur. Will comply. 3. Label index contour so contour interval can be determined. Concur. Will comply. 4. Provide zoning for existing and adjacent parcels. Concur. Will comply. 5. Lot size is smaller than 6,000 square feet allowed by Pulaski County Subdivision and Development Code. Show lot dimensions and bearings on all lots. Concur. Will comply. 6. Show each lot size in acres and square feet. Concur. Will comply. 7. Provide source of water. Concur. Will comply. 8. Provide Arkansas Department of Health approval for wastewater treatment system. Concur. WIII comply. 9. Provide approval from the Volunteer Fire Department. Concur. Will comply. 10. Provide profile for all streets. Concur. Will comply. 11. Label all street centerlines. Concur. Will comply. 12. Provide storm drainage plan. Concur. Will comply. 13. Provide effective FEMA flood panel number. Concur. Will comply. 14. Provide Pulaski County preliminary certificate of approval, not final plat approval. Concur. Will comply. 15. Street names in proposed subdivision are identical to several streets within the City of Little Rock corporate limits. Rename streets as needed to avoid conflicts. Concur. Will comply. 16. Provide full set of construction plans for all streets once PD-R is approved by the City of Little Rock Board of Directors. Concur. Will comply. 17. Front, rear and side setbacks do not comply with Pulaski County Subdivision and Development Code standards. 25-foot front and rear setback is required with an 8-foot side yard setback. Please note that these are being altered as part of the PD-R. 18. Provide SWPPP for Pulaski County review. Concur. Will comply. 19. Pay $132.00 review fee. Concur. WIII comply. Additional Comments — 1. Provide water and wastewater design plans for Public Works review. Concur. Will comply. 2. Provide for maintenance of greenways, common areas, trails, wastewater plant and all leftover tracts in the bill of assurance and on the plat. Concur. Will comply. 3. Obtain appropriate road cut permits from Pulaski County Public Works for Kanis Road. Concur. Will comply. 4. Large Lot #1 at east end of the subdivision should be labeled Lot 6 immediately to the west should be labeled Lot 7. Concur. Will comply. 5. Provide turnarounds at maximum 9-foot intervals for all cul-de-sac streets. Need further clarification. 6. Provide drainage easement as needed between lots. Concur. Will comply. 7. Subject to approval of the PD-R zoning by the City of Little Rock, comments related to lot sizes and setbacks are not applicable. Concur. Will comply. CATA: Buiidinq Code: No Comment Noted. Planning Division; This request is located in the Burlingame Valley Planning District. The Land Use Plan shows Residential Low Density (RL) and Agricultural (A) for this property. The Residential Low Density (RL) category provides for single family homes at densities not to exceed six (6) units per acre. Such residential development is typically characterized by conventional single family homes, but may include patio or garden homes and cluster homes, provided that the density remain less than six (6) units per acre. The Agricultural category is to encourage the continuation of agricultural uses of the land. The agricultural classification also provides for a transition between rural areas and the urban fringe, where it would be appropriate to preserve existing rural land use, prior to annexation into the city. The applicant has applied for a rezoning from R-2 (Single Family District) to PDR (Planned Commercial District) to allow for the development of a single family subdivision on this site. Noted. Master Street ;Plan: Walnut Grove Road is a Principal Arterial and Kanis Road is a Minor Arterial on the Master Street Plan. A Principal Arterial is to serve through traffic and to connect major traffic generators or activity centers within the urbanized area. Entrances and exits should be limited to minimize negative effects of traffic and pedestrians on Walnut Grove Road since it is a Principal Arterial. A Minor Arterial provides connections to and through an urban area and their primary function is to provide short distance travel within the urbanized area. Entrances and exits should be limited to minimize negative effects of traffic and pedestrians on Kanis Road. These streets may require dedication of right-of-way and may require street improvements for entrances and exits to the site. Noted. Bicycle Plan: A Class II Bike Lanes are shown along both Colonel Glenn Road and Lawson Road. Bike Lanes provide a portion of the pavement for the sole use of bicycles. Noted. Landscape: No comment. Noted. Revised plat/Ian: Submit four (4) copies of a revised preliminary plat/plan (to include the additional information as noted above) to staff on Wednesday, May 20, 2015. Concur. Will comply. ITEM NO,: 19. �- 9042 NAME: The Trails Conditional Use Permit LOCATION: located on the Southside of Kanis Road between the Chenal Downs Subdivision and Walnut Grove Road Planning Staff Comments: 1. Provide notification of the property owners located within 200-feet of the development including the certified abstract list, notice form with affidavit executed and proof of mailing. The notice must be mailed no later than May 20, 2015. The Office of Planning and Development must receive the proof of notice no later than May 29, 2015. 2. Provided details of the proposed treatment system, who will permit (State Agency), who will be responsible for maintenance (Property Owners Association/Developer), what are the required setbacks from adjacent properties, what are the discharge requirements and/or perimeters for disposal of treated effluent. 3. Has a permit request been made to the proper permitting agencies to allow for the proposed treatment system? 4. Will the system be located above or below the ground? 5. All subdivisions shall be provided with water supply and distribution systems approved by the city and meeting the requirements of the state health department. Where a public water supply is within a reasonable distance of the subdivision, the subdivider shall install or have installed a system of water mains and connect to such supply. A connection to each lot shall be installed prior to the paving of the street, if possible. 6. Section 31-400 - All subdivisions shall be provided with a sewage collection and treatment system approved by the wastewater utility and/or the state board of health. Where a public sanitary sewer is within a reasonable distance of any point of a subdivision, the subdivider shall connect with such sewer and provide a connection to each lot. Such sanitary sewage system shall be installed prior to the installation of the street pavement. The sewage collection system shall be designed to handle the anticipated flow of sewage from within the subdivision, including development of future sections of the same subdivision and adjacent areas within the same drainage basin. Recognized engineering design criteria in accordance with the state department of health shall be used to design the system. Variance/Waivers: None requested. Public Works Conditions: 1. Kanis Road is classified on the Master Street Plan as a minor arterial. A dedication of right-of-way 45 feet from centerline will be required. 2. Some floodplain is identified on the subject property. Contact Pulaski County Road and Bridge about the conditions for developing in the 100 year floodplain. Utilities and Fire DepartmentlCounty Planning: Wastewater: Outside the service boundary. No comment. Entergy: Entergy does not object to this proposal. A single phase power line exists on the western side of the property, but nowhere else. Service to the proposed lots will be installed and provided along the front lot lines along the new streets. Contact Entergy in advance regarding future service requirements and additional facilities location(s) as this development will require extensive work to install facilities to the 299 proposed lots. Center pint Energy: No comment received. AT & T: No comment received. Central Arkansas Water: 1. All Central Arkansas Water requirements in effect at the time of request for water service must be met. 2. A water main extension will be needed to provide water service to this property. 3. Please submit plans for water facilities and/or fire protection system to Central Arkansas Water for review. Plan revisions may be required after additional review. Contact Central Arkansas Water regarding procedures for installation of water facilities and/or fire service. Approval of plans by the Arkansas Department of Health Engineering Division and the Little Rock Fire Department is required. 4. This development will have minor impact on the existing water distribution system. Proposed water facilities will be sized to provide adequate pressure and fire protection. 5. If there are facilities that need to be adjusted and/or relocated, contact Central Arkansas Water. That work would be done at the expense of the developer. 6. Additional fire hydrant(s) will be required. Contact the Little Rock Fire Department to obtain information regarding the required placement of the hydrant(s) and contact Central Arkansas Water regarding procedures for installation of the hydrant(s). 7. A Capital Investment Charge based on the size of meter connection(s) will apply to this project in addition to normal charges. This fee will apply to all connections including metered connections off the private fire system. Fire ❑e art ent: M i it ip Access. Fire Hydrants. Maintain fire apparatus access roads at fire hydrant locations as per Appendix D of the 2012 Arkansas Fire Prevention Code Vol. 1 Section D103.1 Access road width with a hydrant. Where a fire hydrant is located on a fire apparatus access road, the minimum road width shall be 26 feet, exclusive of shoulders. Grade. Maintain fire apparatus access roads as per Appendix D of the 2012 Arkansas Fire Prevention Code Vol. 1 Section D103.2 Grade. Fire apparatus access roads shall not exceed 10 percent in grade except as approved by the fire chief. Loading. Maintain fire apparatus access road design as per Appendix D of the 2012 Arkansas Fire Prevention Code Vol. 1 Section D102.1 Access and loading. Facilities, buildings or portions of buildings hereafter constructed shall be accessible to fire department apparatus by way of an approved fire apparatus access road with an asphalt, concrete or other approved driving surface capable of supporting the imposed load of fire apparatus weighing at least 75,000 pounds. Dead Ends. Maintain fire apparatus access roads at dead end locations as per Appendix D of the 2012 Arkansas Fire Prevention Code Vol. 1 Section D103.4 Dead Ends. Dead-end fire apparatus access roads in excess of 150 feet shall be provided with width and turnaround provisions in accordance with Table D103.4. Requirements for Dead-end fire apparatus access roads. Gates. Maintain fire apparatus access road gates as per Appendix D of the 2012 Arkansas Fire Prevention Code Vol. 1 Section D103.5 Fire apparatus access road gates. Gates securing the fire apparatus access roads shall comply with all of the following criteria: 1. Minimum gate width shall be 20 feet. 2. Gates shall be of swinging or sliding type. 3. Construction of gates shall be of material that allow manual operation by one person. 4. Gate components shall be maintained in an operable condition at all times and replaces or repaired when defective. 5. Electric gates shall be equipped with a means of opening the gate by fire department personnel for emergency access. Emergency opening devices shall be approved by the fire code official. 6. Manual opening gates shall not be locked with a padlock or chain and padlock unless they are capable of being opened by means of forcible entry tools or when a key box containing the keys to the lock is installed at the gate location. 7. Locking device specifications shall be submitted for approval by the fire code official 8. Electric gate operators, where provided, shall be listed in accordance with UL 325. 9. Gates, intended for automatic operation shall be designed, constructed and installed to comply with requirements of ASTM F 2200. One- or Tw2-.Farn*lv Besidential Qevel2Rm!tntp. There are going to be over 30 houses and code requires two separate access roads, need to connect the roads inside the housing development. As per Appendix D, Section D107.1 of the Arkansas Fire Prevention Code Vol. 1, One- or Two -Family dwelling residential developments. Developments of one- or two-family dwellings where the number of dwelling units exceeds 30 shall be provided with two separate and approved fire apparatus access roads, and shall meet the requirements of Section D104.3. Exceptions: 1. Where there are more than 30 dwelling units on a single public or private fire apparatus access road and al dwelling units are equipped throughout with an approved automatic sprinkler system in accordance with Section 903.3.1.1, 903.3.1.2 or 903.3.1.3 of the Arkansas Fire Code, access from two directions shall not be required. 2. The number of dwelling units on a single fire apparatus access road shall not be increased unless fire apparatus access roads will connect with future development, as determined by the fire code official. Fire Hydrants.. Locate Fire Hydrants as per Appendix C of the 2012 Arkansas Fire Prevention Code. Section C101 — C105, in conjunction with Central Arkansas Water (Daniel Tull 501-377-1245) and the Little Rock ' Fire Marshal's Office (Capt. Tony Rhodes 501-918-3757). Number and Distribution of Fire Hydrants as per Table C105.1. Parks and Recreation: No comment received. County Riannina: 1. Provide Arkansas Department of Health approval for wastewater treatment system. 2. Provide water and wastewater design plans for Public Works review. 3. Provide for maintenance of greenways, common areas, trails, wastewater plant and all leftover tracts in the bill of assurance and on the plat. CATA Building Code: No Comment Landscape: No comment. Revised plat/plan'. Submit four (4) copies of a revised preliminary plat/plan (to include the additional information as noted above) to staff on Wednesday, May 20, 2015. PHILLiP LEWIS ENGINEERING, INC. Structural/Civil Design 2701 Kavanaugh Blvd, Suite 200 Little Rock, Arkansas 72205 Again, I do appreciate the opportunity to present The Trails and look forward to working hand in hand with the City of Little Rock and Pulaski County in making this unique development a reality. Sincerely, Phillip Lewis, P.E. c.501.350.9840 17 May 2015 City of Little Rock Attn: Ms. Donna James Subdivision Administrator 723 West Markham Little Rock, Arkansas 72201 Re: Annotation and Response Letter for "The Trails" Subdivision Long -Form PD-R located on the South side of Kanis Road between the Chenal Downs Subdivision and Walnut Grove Road, Little Rock, Arkansas Donna, We appreciate this opportunity to submit the following annotations and responses to the City of Little Rock's and Pulaski County's (also all utility and fire department) review comments for the above named project otherwise known as "The Trails". Please see the review comments and corresponding annotations and comments below: Planning Staff Comments: 1. Provide notification of the property owners located within 200-feet of the development including the certified abstract list, notice form with affidavit executed and proof of mailing. The notice must be mailed no later than May 20, 2015. The Office of Planning and Development must receive the proof of notice no later than May 29, 2015, Concur. Will Provide. 2. Provide details of any proposed signage. Will there be a subdivision identification sign? Provide the location, total height and total area. Concur. Will Provide. 3. Are interior fences proposed with the new construction or by the future homeowners? Include a note on the site plan including the total height and construction material to allow fencing to occur. Provide details of any perimeter fencing. Yes. Concur. Will Provide note on site plan. 4. The plan as submitted creates streets with lots in excess of 30 homes. The streets must be looped to eliminate this conflict with the Arkansas Fire Code. Will concur with State Fire Marshal's office and West Pulaski County Fire Chief's comments pertaining to this. 5. Are accessory structures allowed, including outbuildings and swimming pools as a part of the Bill of Assurance? If these are desired include a note on the proposed site plan to allow accessory structures per the R-2, Single-family zoning district. Yes. Concur. Will provide in Bill of Assurance. 6. Provide the proposed square footages of the homes. Provide the proposed construction materials. Provide the maximum building height and the number of stories of the proposed structures. Concur. Will Provide. 7. A minimum of ten to fifteen percent of the gross planned residential district area shall be designated as common usable open space and single-family, duplex, zero -lot -line and townhouse development shall have a minimum of five hundred square feet of usable private open space per unit. Indicate the total common usable open space and the total usable private open space provided within the development. Concur. Will comply. 8. Will the development be constructed in multiple phases or in a single phase? Provide the proposed phasing plan. Multiple Phases. VarianCeANaivers: None requested. Public Works Conditions: 1. Kanis Road is classified on the Master Street Plan as a minor arterial. A dedication of right-of-way 45 feet from centerline will be required. Understood — will request waiver of ROW dedication due to the designation of this as a "Scenic Byway" via the tree cover canopy along this stretch of Kanis Road. 2. With site development, provide design of street conforming to the Master Street Plan. Construct one- half street improvement to Kanis Road with planned development. Kanis Road should be improved with pavement provided to 11 feet from centerline and a 4 feet gravel shoulder. At the proposed street intersections at least 36 feet of asphalt should be provided with striping for a left turn lane. Paving should be provided for lane shifts and striping to meet AASHTO standards could may extend beyond the property boundary. Concur. Will provide upgrades where existing grades allow without disturbing trees along Kanis Road that comprise part of the tree cover canopy along Kanis. Please see specific locations denoted (along with proposed phasing) on the plat. Also, please see the attached photos with associated notationstexplanations. 3. Storm water detention ordinance applies to this property. Show the proposed location for stormwater detention facilities on the plan. Concur. Will comply. 4. If disturbed area is 1 or more acres, obtain a NPDES storm water permit from the Arkansas Department of Environmental Quality prior to the start of construction. Concur. Will provide. 5. Kanis Road is on the Master Bike Plan. If bike lanes are desired per the Master Bike Plan and MUTCD standards, the bike lanes should be 6 feet wide measured from the back of curb and provided on both sides of the proposed street. The total street section would be 34 feet wide from back of curb to back of curb. The bike lanes should continue on Kanis Road east and west of the proposed intersections to the side property lines. The paved lane should be 5 feet wide with striping and takes the place of the 4 feet gravel shoulder in these areas. Concur. Will comply where bike lanes are provided. 6. The provided typical road cross section is not accurate and widths are confusing. Concur. Will clarify cross sections. 7. Local streets centerline grade cannot exceed 15% without approval of a variance to the Master Street Plan. Local streets centerline grade cannot exceed 5% at the first 30 feet of an intersection. Concur. Will request variance as required to exceed this maximum slope. 8. Floodplain is shown on the subject property. Contact Pulaski County Road and Bridge for floodplain regulations and conditions. Concur. Will comply. 9. Alteration of the water course will require approval from the Little Rock District of the US Army Corps of Engineers prior to start of work. Concur. No water courses are being altered. 10. Street Improvement plans shall include signage and striping. Public Works must approve completed plans prior to construction. Concur. Will comply. 11. In accordance with Section 31-176, floodway areas must be shown as floodway easements or be dedicated to the public. In addition, a 25 foot wide drainage and access easement is required adjacent to the floodway boundary. Concur. Will provide additional drainage and access easements as noted. 12. Street lights are required by Section 31-403 of the LR code. Provide plans for approval to Traffic Engineering. Street lights must be installed prior to platting/certificate of occupancy. Contact Traffic Engineering, Greg Simmons, gsimmions@littlerock.org or 501.379.1813 for more information. Concur. Will comply and street lights are being provided as part of this project. 13. Per the Master Street Plan, parking is restricted to one side of the street on a 24 feet wide street. Show on the plan now and on the final plat and bill of assurance, the area along the street where parking is allowed. Concur. No 24 feet wide streets are included in the subdivision. 14. Damage to public and private property due to hauling operations or operation of construction related equipment from a nearby construction site shall be repaired by the responsible party prior to issuance of a certificate of occupancy. Concur. Will comply. 15. A minimum undisturbed strip 25 feet wide except for reasonable access shall be provided along each side of streams having a 10 year storm >150 cfs. The undisturbed strip should be measured from the top of the bank. Concur. Will comply. 16. The minimum finish floor elevation as required by Pulaski County is required to be shown on plat and grading plans. Concur. Will provide on lots that are affected. 17. Plans of all work in right-of-way shall be submitted for approval prior to start of work. Concur. Will comply. 18. Provide a letter prepared by a registered engineer certifying the sight distance at the Kanis Road intersection(s) comply with 2004 AASHTO Green Book standards. Concur. Will provide. 19. Repair or replace any curb and gutter or sidewalk that is damaged in the public right-of-way prior to occupancy. Concur. Will comply. 20. Street names and street naming conventions must be approved by Public Works. Contact Glenn Haley at (501) 371-4537. The street names Ridge Trail, Sunset Trail, Fern Trail, and Summit Trail are duplicates. Concur. Will coordinate and correct. 21. The proposed traffic circle should be constructed per AASHTO and FHWA standards with bike lanes and splitter islands. Contact Nat Banihatti in Traffic Engineering at 501-379-1818 for additional information. Concur. Will comply. 22. Traffic calming devices are required for long straight streets to discourage speeding. Traffic circles or round -about are suggested at regular intervals and at main intersections. Contact Travis Herbner, Traffic Engineering. at 379-1805 for additional info. Concur. Will provide as required. 23. The accel and decel lanes on Kanis Road should not be constructed. Concur. Will be deleted from project. 24. Emergency access should be provided for area of subdivisions with 30 for more homes and only 1 access. Will concur with State Fire Marshal's office and West Pulaski County Fire Chief's comments pertaining to this. 25. Walnut Grove Road is classified on the Master Street Plan as a principal arterial. Dedication of right- of-way to 55 feet from centerline will be required. Per the Master Street Plan at the intersection of arterial/arterial intersections, an additional 10 feet of right-of-way should be dedicated for a right turn lane for a length of 250 feet. The total width of dedication is 65 feet. Concur. Will dedicate additional Right -Of -Way but are requesting waiver for half street improvements as this is a long term upgrade for Walnut Grove Road. 26. Per the Master Street Plan at arterial/arterial intersections, a 100 feet radial dedication of right-of-way is required at the intersection of Walnut Grove Rd and Kanis Rd. Concur. Will dedicate Right -of - Way as required. 27. Sidewalk should be installed along Summit Trail south of traffic circle. The sidewalk should be on the outside of the circle portion of Summit Trail. We are providing trails throughout the subdivision in lieu of sidewalks. 28. The minimum stopping sight distance of 155 feet or latest AASHTO policy on Geometric Design Manual and 150 feet minimum horizontal radius at centerline. Concur. Will comply and request variance if required regarding stopping distance and sight distance. Utilities and Fire Department/County Planning: Wastewater: Outside the service boundary, no comment. Noted. Entergy: Entergy does not object to this proposal. A single phase power line exists on the western side of the property, but nowhere else. Service to the proposed lots will be installed and provided along the front lot lines along the new streets. Contact Entergy in advance regarding future service requirements and additional facilities location(s) as this development will require extensive work to install facilities to the 299 proposed lots. Concur. Noted. Centerpoint Energy: No comment received. Noted. AT & T: No comment received. Noted. Central Arkansas Water: 1. All Central Arkansas Water requirements in effect at the time of request for water service must be met. Concur. Will comply. 2. A water main extension will be needed to provide water service to this property. Concur. Will provide. 3. Please submit plans for water facilities and/or fire protection system to Central Arkansas Water for review. Plan revisions may be required after additional review. Contact Central Arkansas Water regarding procedures for installation of water facilities and/or fire service. Approval of plans by the Arkansas Department of Health Engineering Division and the Little Rock Fire Department is required. Concur. Will comply. 4. This development will have minor impact on the existing water distribution system. Proposed water facilities will be sized to provide adequate pressure and fire protection. Concur. Will comply. 5. If there are facilities that need to be adjusted and/or relocated, contact Central Arkansas Water. That work would be done at the expense of the developer. Concur. Will comply. 6. Additional fire hydrant(s) will be required. Contact the Little Rock Fire Department to obtain information regarding the required placement of the hydrant(s) and contact Central Arkansas Water regarding procedures for installation of the hydrant(s). Concur. Will provide. 7. A Capital Investment Charge based on the size of meter connection(s) will apply to this project in addition to normal charges. This fee will apply to all connections including metered connections off the private fire system. Concur. Noted. Fire Department: Main1lin A Fire Hydrant& Maintain fire apparatus access roads at fire hydrant locations as per Appendix D of the 2012 Arkansas Fire Prevention Code Vol. 1 Section D103.1 Access road width with a hydrant. Where a fire hydrant is located on a fire apparatus access road, the minimum road width shall be 26 feet, exclusive of shoulders. Concur. Will comply. Grade. Maintain fire apparatus access roads as per Appendix D of the 2012 Arkansas Fire Prevention Code Vol. 1 Section D103.2 Grade. Fire apparatus access roads shall not exceed 10 percent in grade except as approved by the fire chief. Concur. Will comply. Loading. Maintain fire apparatus access road design as per Appendix D of the 2012 Arkansas Fire Prevention Code Vol. 1 Section D102.1 Access and loading. Facilities, buildings or portions of buildings hereafter constructed shall be accessible to fire department apparatus by way of an approved fire apparatus access road with an asphalt, concrete or other approved driving surface capable of supporting the imposed load of fire apparatus weighing at least 75,000 pounds. Concur. Will comply. Dead Ends. Maintain fire apparatus access roads at dead end locations as per Appendix D of the 2012 Arkansas Fire Prevention Code Vol. 1 Section D103.4 Dead Ends. Dead-end fire apparatus access roads in excess of 150 feet shall be provided with width and turnaround provisions in accordance with Table D103.4. Requirements for Dead-end fire apparatus access roads. Concur. Will provide. _Gates. Maintain fire apparatus access road gates as per Appendix D of the 2012 Arkansas Fire Prevention Code Vol. 1 Section D103.5 Fire apparatus access road gates. Gates securing the fire apparatus access roads shall comply with all of the following criteria: 1. Minimum gate width shall be 20 feet. Concur. Will comply. 2. Gates shall be of swinging or sliding type. Concur. Will comply. 3. Construction of gates shall be of material that allow manual operation by one person. Concur. Will comply. 4. Gate components shall be maintained in an operable condition at all times and replaces or repaired when defective. Concur. Will comply. 5. Electric gates shall be equipped with a means of opening the gate by fire department personnel for emergency access. Emergency opening devices shall be approved by the fire code official. Concur. Will comply. 6. Manual opening gates shall not be locked with a padlock or chain and padlock unless they are capable of being opened by means of forcible entry tools or when a key box containing the keys to the lock is installed at the gate location. Concur. Will comply. 7. Locking device specifications shall be submitted for approval by the fire code official Concur. Will comply. 8. Electric gate operators, where provided, shall be listed in accordance with UL 325. Concur. Will comply. 9. Gates, intended for automatic operation shall be designed, constructed and installed to comply with requirements of ASTM F 2200. Concur. Will comply. One- or Two -Family Residential Developments.— evelo ments. There are going to be over 30 houses and code requires two separate access roads, need to connect the roads inside the housing development. As per Appendix D, Section D107.1 of the Arkansas Fire Prevention Code Vol. 1, One- or Two -Family dwelling residential developments. Developments of one- or two-family dwellings where the number of dwelling units exceeds 30 shall be provided with two separate and approved fire apparatus access roads, and shall meet the requirements of Section D104.3. Will concur with State Fire Marshal's office and West Pulaski County Fire Chiefs comments pertaining to this Exceptions: 1. Where there are more than 30 dwelling units on a single public or private fire apparatus access road and al dwelling units are equipped throughout with an approved automatic sprinkler system in accordance with Section 903.3.1.1, 903.3.1.2 or 903.3.1.3 of the Arkansas Fire Code, access from two directions shall not be required. 2. The number of dwelling units on a single fire apparatus access road shall not be increased unless fire apparatus access roads will connect with future development, as determined by the fire code official. Fire Hydrants. Locate Fire Hydrants as per Appendix C of the 2012 Arkansas Fire Prevention Code. Section C101 — C105, in conjunction with Central Arkansas Water (Daniel Tull 501-377-1245) and the Little Rock Fire Marshal's Office (Capt. Tony Rhodes 501-918-3757). Number and Distribution of Fire Hydrants as per Table C105.1. Concur. Will comply. Parks and Recreation: No comment received. Noted. County Planning 1. Provide Bill of Assurance. Concur. Will comply. 2. Show State Plane coordinates for two corners. Concur. Will comply. 3. Label index contour so contour interval can be determined. Concur. Will comply. 4. Provide zoning for existing and adjacent parcels. Concur. Will comply. 5. Lot size is smaller than 6,000 square feet allowed by Pulaski County Subdivision and Development Code. Show lot dimensions and bearings on all lots. Concur. Will comply. 6. Show each lot size in acres and square feet. Concur. Will comply. 7. Provide source of water. Concur. Will comply. 8. Provide Arkansas Department of Health approval for wastewater treatment system. Concur. Will comply. 9. Provide approval from the Volunteer Fire Department. Concur. Will comply. 10. Provide profile for all streets. Concur. Will comply. 11. Label all street centerlines. Concur. Will comply. 12. Provide storm drainage plan. Concur. Will comply. 13. Provide effective FEMA flood panel number. Concur. Will comply. 14. Provide Pulaski County preliminary certificate of approval, not final plat approval. Concur. Will comply. 15. Street names in proposed subdivision are identical to several streets within the City of Little Rock corporate limits. Rename streets as needed to avoid conflicts. Concur. Will comply. 16. Provide full set of construction plans for all streets once PD-R is approved by the City of Little Rock Board of Directors. Concur. Will comply. 17. Front, rear and side setbacks do not comply with Pulaski County Subdivision and Development Code standards. 25-foot front and rear setback is required with an 8-foot side yard setback. Please note that these are being altered as part of the PD-R. 18. Provide SWPPP for Pulaski County review. Concur. Will comply. 19. Pay $132.00 review fee. Concur. Will comply. Additional Comments — 1. Provide water and wastewater design plans for Public Works review. Concur. Will comply. 2. Provide for maintenance of greenways, common areas, trails, wastewater plant and all leftover tracts in the bill of assurance and on the plat. Concur. Will comply. 3. Obtain appropriate road cut permits from Pulaski County Public Works for Kanis Road. Concur. Will comply. 4. Large Lot #1 at east end of the subdivision should be labeled Lot 6 immediately to the west should be labeled Lot 7. Concur. Will comply. 5. Provide turnarounds at maximum 9-foot intervals for all cul-de-sac streets. Need further clarification. 6. Provide drainage easement as needed between lots. Concur. Will comply. 7. Subject to approval of the PD-R zoning by the City of Little Rock, comments related to lot sizes and setbacks are not applicable. Concur. Will comply. CATA: Building Code: No Comment Noted. Plannina Division, This request is located in the Burlingame Valley Planning District. The Land Use Plan shows Residential Low Density (RL) and Agricultural (A) for this property. The Residential Low Density (RL) category provides for single family homes at densities not to exceed six (6) units per acre. Such residential development is typically characterized by conventional single family homes, but may include patio or garden homes and cluster homes, provided that the density remain less than six (6) units per acre. The Agricultural category is to encourage the continuation of agricultural uses of the land. The agricultural classification also provides for a transition between rural areas and the urban fringe, where it would be appropriate to preserve existing rural land use, prior to annexation into the city. The applicant has applied for a rezoning from R-2 (Single Family District) to PDR (Planned Commercial District) to allow for the development of a single family subdivision on this site. Noted. Master Street Plan: Walnut Grove Road is a Principal Arterial and Kanis Road is a Minor Arterial on the Master Street Plan. A Principal Arterial is to serve through traffic and to connect major traffic generators or activity centers within the urbanized area. Entrances and exits should be limited to minimize negative effects of traffic and pedestrians on Walnut Grove Road since it is a Principal Arterial. A Minor Arterial provides connections to and through an urban area and their primary function is to provide short distance travel within the urbanized area. Entrances and exits should be limited to minimize negative effects of traffic and pedestrians on Kanis Road. These streets may require dedication of right-of-way and may require street improvements for entrances and exits to the site. Noted. BicYf,le Plan: A Class II Bike Lanes are shown along both Colonel Glenn Road and Lawson Road. Bike Lanes provide a portion of the pavement for the sole use of bicycles. Noted. Landscape: No comment. Noted. Revised-plat/plan: Submit four (4) copies of a revised preliminary plat/plan (to include the additional information as noted above) to staff on Wednesday, May 20, 2015. Concur. Will comply. ITEM NO.: 19. Z- 9042 NAME: The Trails Conditional Use Permit LOCATION: located on the Southside of Kanis Road between the Chenal Downs Subdivision and Walnut Grove Road Planning %aff Comment: 1. Provide notification of the property owners located within 200-feet of the development including the certified abstract list, notice form with affidavit executed and proof of mailing. The notice must be mailed no later than May 20, 2015. The Office of Planning and Development must receive the proof of notice no laterthan May 29, 2015. 2. Provided details of the proposed treatment system, who will permit (State Agency), who will be responsible for maintenance (Property Owners Association/Developer), what are the required setbacks from adjacent properties, what are the discharge requirements and/or perimeters for disposal of treated effluent. 3. Has a permit request been made to the proper permitting agencies to allow for the proposed treatment system? 4. Will the system be located above or below the ground? 5. All subdivisions shall be provided with water supply and distribution systems approved by the city and meeting the requirements of the state health department. Where a public water supply is within a reasonable distance of the subdivision, the subdivider shall install or have installed a system of water mains and connect to such supply. A connection to each lot shall be installed prior to the paving of the street, if possible. 6. Section 31-400 - All subdivisions shall be provided with a sewage collection and treatment system approved by the wastewater utility and/or the state board of health. Where a public sanitary sewer is within a reasonable distance of any point of a subdivision, the subdivider shall connect with such sewer and provide a connection to each lot. Such sanitary sewage system shall be installed prior to the installation of the street pavement. The sewage collection system shall be designed to handle the anticipated flow of sewage from within the subdivision, including development of future sections of the same subdivision and adjacent areas within the same drainage basin. Recognized engineering design criteria in accordance with the state department of health shall be used to design the system. Variance/Waivers: None requested. Public Works Conditions: 1. Kanis Road is classified on the Master Street Plan as a minor arterial. A dedication of right-of-way 45 feet from centerline will be required. 2. Some floodplain is identified on the subject property. Contact Pulaski County Road and Bridge about the conditions for developing in the 100 year floodplain. Utilities and Fire Department/County Planning: Wastewater'. Outside the service boundary. No comment. Entergy: Entergy does not object to this proposal. A single phase power line exists on the western side of the property, but nowhere else. Service to the proposed lots will be installed and provided along the front lot lines along the new streets. Contact Entergy in advance regarding future service requirements and additional facilities location(s) as this development will require extensive work to install facilities to the 299 proposed lots. Centerpoint Energy: No comment received. AT & T: No comment received. Central Arkansas Water; 1. All Central Arkansas Water requirements in effect at the time of request for water service must be met. 2. A water main extension will be needed to provide water service to this property. 3. Please submit plans for water facilities and/or fire protection system to Central Arkansas Water for review. Plan revisions may be required after additional review. Contact Central Arkansas Water regarding procedures for installation of water facilities and/or fire service. Approval of plans by the Arkansas Department of Health Engineering Division and the Little Rock Fire Department is required. 4. This development will have minor impact on the existing water distribution system. Proposed water facilities will be sized to provide adequate pressure and fire protection. 5. If there are facilities that need to be adjusted and/or relocated, contact Central Arkansas Water. That work would be done at the expense of the developer. 6. Additional fire hydrant(s) will be required. Contact the Little Rock Fire Department to obtain information regarding the required placement of the hydrant(s) and contact Central Arkansas Water regarding procedures for installation of the hydrant(s). 7. A Capital Investment Charge based on the size of meter connection(s) will apply to this project in addition to normal charges. This fee will apply to all connections including metered connections off the private fire system. Fire De artment- Maintain Access. Fire Hydrants. Maintain fire apparatus access roads at fire hydrant locations as per Appendix D of the 2012 Arkansas Fire Prevention Code Vol. 1 Section D103.1 Access road width with a hydrant. Where a fire hydrant is located on a fire apparatus access road, the minimum road width shall be 26 feet, exclusive of shoulders. Grade. Maintain fire apparatus access roads as per Appendix D of the 2012 Arkansas Fire Prevention Code Vol. 1 Section D103.2 Grade. Fire apparatus access roads shall not exceed 10 percent in grade except as approved by the fire chief. Loadina. Maintain fire apparatus access road design as per Appendix D of the 2012 Arkansas Fire Prevention Code Vol. 1 Section D102.1 Access and loading. Facilities, buildings or portions of buildings hereafter constructed shall be accessible to fire department apparatus by way of an approved fire apparatus access road with an asphalt, concrete or other approved driving surface capable of supporting the imposed load of fire apparatus weighing at least 75,000 pounds. Dead Ends. Maintain fire apparatus access roads at dead end locations as per Appendix D of the 2012 Arkansas Fire Prevention Code Vol. 1 Section D103.4 Dead Ends. Dead-end fire apparatus access roads in excess of 150 feet shall be provided with width and turnaround provisions in accordance with Table D103.4. Requirements for Dead-end fire apparatus access roads. Gates. Maintain fire apparatus access road gates as per Appendix D of the 2012 Arkansis Fire Prevention Code Vol. 1 Section D103.5 Fire apparatus access road gates. Gates securing the fire apparatus access roads shall comply with all of the following criteria: 1. Minimum gate width shall be 20 feet. 2. Gates shall be of swinging or sliding type. 3. Construction of gates shall be of material that allow manual operation by one person. 4. Gate components shall be maintained in an operable condition at all times and replaces or repaired when defective. 5. Electric gates shall be equipped with a means of opening the gate by fire department personnel for emergency access. Emergency opening devices shall be approved by the fire code official. 6. Manual opening gates shall not be locked with a padlock or chain and padlock unless they are capable of being opened by means of forcible entry tools or when a key box containing the keys to the lock is installed at the gate location. 7. Locking device specifications shall be submitted for approval by the fire code official 8. Electric gate operators, where provided, shall be listed in accordance with UL 325. 9. Gates, intended for automatic operation shall be designed, constructed and installed to comply with requirements of ASTM F 2200. One- or Two -Family i nti I Developments. There are going to be over 30 houses and code requires two separate access roads, need to connect the roads inside the housing development. As per Appendix D, Section D107.1 of the Arkansas Fire Prevention Code Vol. 1, One- or Two -Family dwelling residential developments. Developments of one- or two-family dwellings where the number of dwelling units exceeds 30 shall be provided with two separate and approved fire apparatus access roads, and shall meet the requirements of Section D104.3. Exceptions: 1. Where there are more than 30 dwelling units on a single public or private fire apparatus access road and al dwelling units are equipped throughout with an approved automatic sprinkler system in accordance with Section 903.3.1.1, 903.3.1.2 or 903.3.1.3 of the Arkansas Fire Code, access from two directions shall not be required. 2. The number of dwelling units on a single fire apparatus access road shall not be increased unless fire apparatus access roads will connect with future development, as determined by the fire code official. Fire Hydrants. Locate Fire Hydrants as per Appendix C of the 2012 Arkansas Fire Prevention Code. Section C101 — C105, in conjunction with Central Arkansas Water (Daniel Tull 501-377-1245) and the Little Rock ' Fire Marshal's Office (Capt. Tony Rhodes 501-918-3757). Number and Distribution of Fire Hydrants as per Table C105.1. Parks and Recreation: No comment received. County Plannina: 1. Provide Arkansas Department of Health approval for wastewater treatment system. 2. Provide water and wastewater design plans for Public Works review. 3. Provide for maintenance of greenways, common areas, trails, wastewater plant and all leftover tracts in the bill of assurance and on the plat. CATA: Building Code: No Comment Landscape: No comment. Revised latl lan: Submit four (4) copies of a revised preliminary plat/plan (to include the additional information as noted above) to staff on Wednesday, May 20, 2015.