HomeMy WebLinkAboutZ-8978 Staff AnalysisFILE NO.:
NAME: Lucy Self Storage Long -form PD-C
LOCATION: Located at 10616 Stagecoach Road
DEVELOPER:
Walter Lucy
c/o Olan Asbury
P.O. Box 241087
Little Rock, AR 72223
ENGINEER:
Thomas Engineering
2810 Lookout
North Little Rock, AR 72216
AREA: 2.92 acres
CURRENT ZONING
ALLOWED USES:
PROPOSED ZONING
ROPOSED USE
NUMBER OF LOTS: 1
R-2, Non -conforming
Non -conforming salvage yard
P D-C
Mini -warehouse
FT. NEW STREET: 0 LF
VARIANCEANAIVERS: A variance from Sections 30-43 and 31-210 to allow the
driveways nearer the property lines and with less distance separating the drives than
typical ordinance standard
A. PROPOSAL/REQUEST/APPLICANT'S STATEMENT:
The request is a rezoning from R-2, Single-family to PD-C to allow the use of the
property as a mini -warehouse facility. The site currently contains an auto
salvage yard which will be removed upon approval of the PD-C. The
development is proposed with five (5) buildings of mini -warehouse. The site plan
indicates the placement of an on -site manager's residence included within the
office area. The applicant has stated the manager will live on -site. The office
hours of the development are from 9 am to 5 pm Monday through Friday and
9 am to noon on Saturday. The owner will not encourage 24-hour access to the
FILE NO.: Z-8978 (Cont.
property but customers will have 24-hour access to their units. The property will
include climate controlled storage units and standard storage units. The unit mix
has not been determined but the mix is expected to be 50/50.
B. EXISTING CONDITIONS:
C
The site is being used as an auto salvage yard with a number of vehicles stored
on the site. To the west is a property zoned PCD which has developed with a
strip retail center, a carwash fronting on Kanis Road and mini -warehouse units in
the rear. North of this site is a vacant C-2 zoned property. Further north is a
shopping center, mini -warehouse units, a convenience store and a drive -through
restaurant. South of the site are single-family homes located on large lots or
acreage. Within the general area there are a number of residential and
non-residential uses including multi -family apartments and an office warehouse
development.
NEIGHBORHOOD COMMENTS:
As of this writing, staff has received several informational phone calls from area
residents. All property owners located within 200-feet of the site along with the
Otter Creek Homeowners Association and Southwest Little Rock United for
Progress were notified of the public hearing.
D. ENGINEERING COMMENTS:
PUBLIC WORKS CONDITIONS:
1. Stagecoach Road is classified on the Master Street Plan as a minor arterial.
A dedication of right-of-way 45-feet from centerline will be required.
2. In accordance with Section 31-210 (h)(12), access driveways running parallel
to the street shall not create a four-way intersection within 75-feet of the
future curb line of the street.
3. A grading permit in accordance with Section 29-186 (c) and (d) will be
required prior to any land clearing or grading activities at the site. Other than
residential subdivisions, site grading and drainage plans must be submitted
and approved prior to the start of construction. Is construction of the
development proposed to be phased and a variance requested to advance
grade the entire property?
4. Obtain permits for improvements within State Highway right-of-way from
AHTD, District VI.
5. Stormwater detention ordinance applies to this property.
6. If disturbed area is one (1) or more acres, obtain a NPDES stormwater permit
from the Arkansas Department of Environmental Quality prior to the start of
construction.
2
FILE NO.: Z-8978 (Cont.
7. Driveway locations and widths do not meet the traffic access and circulation
requirements of Sections 30-43 and 31-210. Driveways on minor arterial
streets should be spaced 300-feet from other driveways and intersections and
150-feet from the side property line. The width of driveway must not exceed
36-feet. A driveway variance must be requested.
8. Show the location proposed gate controller. The controller must be located at
least 60-feet from the Stagecoach Road curb.
E. UTILITIES AND FIRE DEPARTMENT/COUNTY PLANNING;
Wastewater: Sewer available to this project.
Entergy: Entergy does not object to this proposal. A 3-phase line exists in front
of the property with CATV attachments to the poles. Care should be taken to
ensure adequate clearance exists before moving large equipment or structures
underneath the lines. Contact Entergy in advance for service requirements and
to determine locations of required facilities.
Center -Point Energy: No comment received.
AT & T: No comment received.
Central Arkansas Water:
1. All Central Arkansas Water requirements in effect at the time of request for
water service must be met.
2. A water main extension will be needed to provide water service to this
property.
3. The Little Rock Fire Department needs to evaluate this site to determine
whether additional public and/or private fire hydrant(s) will be required.
If additional fire hydrant(s) are required, they will be installed at the
Developer's expense.
4. Please submit plans for water facilities and/or fire protection system to
Central Arkansas Water for review. Plan revisions may be required after
additional review. Contact Central Arkansas Water regarding procedures
for installation of water facilities and/or fire service. Approval of plans by the
Arkansas Department of Health Engineering Division and the Little Rock
Fire Department is required.
5. If there are facilities that need to be adjusted and/or relocated, contact
Central Arkansas Water. That work would be done at the expense of the
developer.
6. Contact Central Arkansas Water if additional fire protection or metered
water service is required.
3
FILE NO.: Z-8978 �Cont_
7. Due to the nature of this facility, installation of an approved reduced
pressure zone backflow preventer assembly (RPZA) is required on the
domestic water service. This assembly must be installed prior to the first
point of use. Central Arkansas Water requires that upon installation of the
RPZA, successful tests of the assembly must be completed by a Certified
Assembly Tester licensed by the State of Arkansas and approved by
Central Arkansas Water. The test results must be sent to Central Arkansas
Water's Cross Connection Section within ten days of installation and
annually thereafter. Contact the Cross Connection Section at 501.377.1226
if you would like to discuss backflow prevention requirements for this
project.
8. The facilities on -site will be private. When meters are planned off private
lines, private facilities shall be installed to Central Arkansas Water's material
and construction specifications and installation will be inspected by an
engineer, licensed to practice in the State of Arkansas. Execution of
Customer Owned Line agreement is required.
9. Fire sprinkler systems which do not contain additives such as antifreeze
shall be isolated with a double detector check valve assembly. If additives
are used, a reduced pressure zone backflow preventer shall be required.
10. This development will have minor impact on the existing water distribution
system. Proposed water facilities will be sized to provide adequate
pressure and fire protection.
Fire Department: Fire hydrants per code, maintain access per code, drive lanes
24-feet, gates 20-feet per code. Contact the Little Rock Fire Department for
additional information.
County Planning: No comment.
CATA: The area is currently served by CATA at this location by Route #23,
Baseline Southwest. While this location is in CATA's service area, the small
single business unit should not generate significant ridership so CATA only
requests ADA compliant sidewalks are required at this location.
Parks and Recreation: No comment received.
F. ISSUES/TECHNICAUDESIGN:
Building Code: Project is subject to full commercial plan review approval prior
to issuance of a building permit. For information on submittal requirements and
the review process, contact a commercial plans examiner: Curtis Richey at
501.371.4724; criche Iittlerock. or or Mark Alderfer at 501.371.4875;
malderferEwlittlerock.org.
9
FILE NO.: Z-8978 (C
Planning Division: This request is located in the Otter Creek Planning District.
The Land Use Plan shows Service Trades District (STD) for this property. The
Service Trades District provides for a selection of office, warehousing, and
industrial park activities that primarily serve other office service or industrial
businesses. The district is intended to allow support services to these businesses
and to provide for uses with an office component. A Planned Zoning District is
required for any development not wholly office. The applicant has applied for a
rezoning from R-2 (Single Family District) to PDC (Planned District Commercial)
to allow the construction of a mini -warehouse development on this site.
Master Street Plan: Stagecoach Road is a Minor Arterial Street on the Master
Street Plan. A Minor Arterial provides connections to and through an urban area
and their primary function is to provide short distance travel within the urbanized
area. Entrances and exits should be limited to minimize negative effects of traffic
and pedestrians on Stagecoach Road. This street may require dedication of
right-of-way and may require street improvements for entrances and exits to the
site.
Bicycle Plan: A Class II Bike Lane is shown along Stagecoach Road.
Bike Lanes provide a portion of the pavement for the sole use of bicycles.
Landscape:
1. Site plan must comply with the City's landscape and buffer ordinance
requirements.
2. Street buffers will be required at six (6) percent of the average depth of the
lot. The minimum dimension shall be one-half ('/2) the full width requirement
but in no case less than nine (9) feet. Easements cannot count toward
fulfilling this requirement. The plantings, existing and purposed, shall be
provided within the City's landscape ordinance requirements.
a. The approximate average depth of the north tract is four hundred and
ninety (490) feet. An average thirty-nine foot (39) foot wide buffer is
required along Stagecoach Road.
3. A perimeter planting strip is required along any side of a vehicular use area
that abuts adjoining property. This strip shall be at least nine (9) feet wide.
Provide trees with an average linear spacing of not less than thirty (30) feet
within the perimeter planting strip. Provide three (3) shrubs or vines for every
thirty (30) linear feet of perimeter planting strip.
4. Landscape areas shall be provided between the vehicular use area used for
public parking and the general vicinity of the building, excluding truck loading
or service areas not open to public parking. These areas shall be equal to an
equivalent planter strip three (3) feet wide along the vehicular use area.
5. A landscape irrigation system shall be required for developments of
one (1) acre or larger.
5
FILE NO.: Z-8978 (Cont.
6. The City Beautiful Commission recommends preserving as many existing
trees as feasible on this site. Credit toward fulfilling Landscape Ordinance
requirements can be given when preserving trees of six (6) inch caliper or
larger.
G. SUBDIVISION COMMITTEE COMMENT: (October 8, 2014)
The applicant was present. Staff presented an overview of the item stating there
were additional items in need of addressing related to the development plan prior
to the full Commission acting on the request. Staff requested the applicant
provide the days and hours of operation, if there would be on -site management,
the location of any proposed dumpster facilities, any areas of outdoor storage
and the proposed signage plan.
Public Works comments were addressed. Staff stated the driveways did not
comply with the typical standards of the Master Street Plan and the Subdivision
Ordinance. Staff also stated the City's stormwater detention ordinance would
apply to the development of the site. Staff questioned if the development would
be phased and if the developer was requesting to grade future phases of
construction with the initial phase of dirt work. Staff stated a grading permit
would be required prior to development of the site.
Landscaping comments were addressed. Staff stated street buffers were
required along Stagecoach Road. Staff also stated an automatic irrigation
system would be required to water landscaped areas. Staff noted interior
landscaping would be required within the parking lot areas. Staff requested the
applicant provide the proposed fencing material and the location of any proposed
fencing in a note on the site plan.
Staff noted the comments from the various other agencies. There were no more
issues for discussion. The Committee then forwarded the item to the full
Commission for final action.
H. ANALYSIS:
The applicant submitted a revised site plan to staff addressing the issues raised
at the October 8, 2014, Subdivision Committee meeting. The revised plan has
provided the days and hours of operation, the dumpster facilities and the
proposed signage plan.
The request is a rezoning from R-2, Single-family to PD-C to allow the reuse of
the property with mini -warehouse units. The site currently contains an auto
salvage yard which will be removed upon approval of the PD-C. The
development is proposed with five (5) buildings of mini -warehouse. The property
will include climate controlled storage units and standard storage units. The unit
mix has not been determined but the mix is expected to be 50/50. The site plan
indicates the placement of an on -site manager's office and residence. The
A
FILE NO.: Z-8978 (Cont.
applicant has stated the manager will live on -site. Businesses will not be
allowed to operate from the individual storage units.
The office hours of the development are from 9 am to 5 pm Monday through
Friday and 9 am to noon on Saturday. The owner will not encourage 24-hour
access to the property but customers will have 24-hour access to their units.
The site plan indicates the use of the rears of the building as screening for the
site. Fencing will be placed within the areas of the site where there are breaks in
the buildings. The fencing proposed is a six (6) foot wood fence. Ornamental
metal fencing will be placed along the street frontage. The site plan does not
include areas of outdoor storage. The applicant has indicated the intent is to limit
areas of outdoor activities but in some instances boats, trailers, campers and
Rv's may be parked on the site.
The site plan indicates a single ground sign will be located along Stagecoach
Road. The sign height and area will be consistent with signage allowed in
commercial zones (maximum 36-feet in height and 160 square feet in area).
Building signage is limited to the front facade of Building C. The sign will comply
with wall signage allowed in commercial zones or a maximum of ten (10) percent
of the facade area.
The applicant has stated there will not be dumpsters located on the site. Staff
feels if dumpsters are warranted in the future the dumpsters be placed to limit
intrusion on the abutting properties and the hours of dumpster service be limited
to 7 am to 6 pm Monday through Friday.
The applicant is requesting a variance from the City's Land Alteration Ordinance
to allow advanced grading of the site. The applicant has indicated the buildings
will be constructed in multiple phases. The applicant is requesting the ability to
grade the entire site with the construction of the first building. The buildings will
be constructed based on market demand.
The request includes a variance from Sections 30-43 and 31-210. Driveways on
minor arterial streets should be spaced 300-feet from other driveways and
intersections and 150-feet from the side property line. The width of driveway
must not exceed 36-feet. One driveway is located 136-feet from the north
property line and 110-feet from the south property line. Center to center the
drives are located 270-feet apart.
Staff is supportive of the applicant's request. The site has a long history of a
non-residential use. This area of Stagecoach Road is primarily non-residential.
Although there are variances associated with the request staff feels the
developers have done an adequate job in minimizing any potential adverse
impact on the adjacent properties or the area.
7
FILE NO.: Z-8978
STAFF RECOMMENDATION:
Staff recommends approval of the request subject to compliance with the
comments and conditions as outlined in paragraphs D, E and F of the agenda
staff report.
Staff recommends approval of the variance request to allow advanced grading of
the site with the construction of the first building on the site.
Staff recommends approval of the variance from Sections 30-43 and 31-210 to
allow the placement of the drives nearer the property lines and with less distance
between the drives than typically required per City ordinance.
PLANNING COMMISSION ACTION: (OCTOBER 30, 2014)
The applicant was present. There were no registered objectors present. Staff
presented the item with a recommendation of approval of the request subject to
compliance with the comments and conditions as outlined in paragraphs D, E and F of
the agenda staff report. Staff presented a recommendation of approval of the variance
request to allow advanced grading of the site with the construction of the first building
on the site. Staff presented a recommendation of approval of the variance from
Sections 30-43 and 31-210 to allow the placement of the drives nearer the property
lines and with less distance between the drives than typically required per
City ordinance.
There was no further discussion of the item. The Chair entertained a motion for
approval of the item, as presented by staff. The motion carried by a vote of 11 ayes
0 noes and 0 absent.
0
ITEM NO.: 13.
NAME: Lucy Self Storage Long -form PD-C
LOCATION: located at 10616 Stagecoach Road
Planning Staff Comments:
1. Provide notification of property owners located within 200-feet of the site including
the certified abstract list, notice form with affidavit executed and proof of mailing.
The notice must be mailed no later than October 15, 2014, The Office of Planning
and Development must receive the proof of notice no later than October 24, 2014.
2. Provide the proposed signage plan for the development. Include the building
signage plan as well as the ground signage plan. Include the percentage of fagade
area proposed with signage for building signage and the fagade the signs are to be
located. Provide the location of any ground signage including the total height and
total sign area.
3. Provide the days and hours of operation for the facility. Will the units have 24-hour
access?
4. Will there be an on -site manager?
5. Will there be conditioned units as well as non -conditioned units located on the site?
6. Will each of the units have separate electrical and lighting?
7. Will there be areas for outdoor storage of boats, campers or RV's? If so note on the
site plan the location for outdoor activities.
8. Will there be any perimeter fencing located on the site? If so provide a note
indicating the location of any fencing and provide a note concerning the construction
material.
9. Will there be a dumpster located on the site? Provide the location of any proposed
dumpster facilities and include a note concerning the required screening.
10. Will the dumpster service hours be limited? If so note the hours of dumpster service
on the site plan.
11. There is to be no business activities conducted from the individual storage units.
12.The PZD Section of the Ordinance states -
a. Perimeter treatment. Notwithstanding any other provisions of a planned
zoning district, all uses of land or structures shall meet the open space,
buffer or green strip provisions of this chapter and Chapters 15 and 21 of
this Code.
b. Open space. Well designed open space is an important factor in providing
for innovative design and visual attractiveness. Open space shall be
evaluated utilizing the following general guidelines: A minimum of ten (10)
percent of gross planned commercial mixed use district (PCD) or planned
office district (POD) area shall be designated as landscaped open space
not to be used for streets or parking.
ITEM NO.:
Z-8978
Variance/Waivers', Driveway spacing
Public Works Conditions:
1. Stagecoach Road is classified on the Master Street Plan as a minor arterial. A
dedication of right-of-way 45-feet from centerline will be required.
2. In accordance with Section 31-210 (h)(12), access driveways running parallel to the
street shall not create a four-way intersection within 75-feet of the future curb line of
the street.
3. A grading permit in accordance with Section 29-186 (c) and (d) will be required prior
to any land clearing or grading activities at the site. Other than residential
subdivisions, site grading and drainage plans must be submitted and approved prior
to the start of construction. Is construction of the development proposed to be
phased and a variance requested to advance grade the entire property?
4. Obtain permits for improvements within State Highway right-of-way from AHTD,
District VI.
5. Stormwater detention ordinance applies to this property.
6. If disturbed area is one (1) or more acres, obtain a NPDES stormwater permit from
the Arkansas Department of Environmental Quality prior to the start of construction.
7. Driveway locations and widths do not meet the traffic access and circulation
requirements of Sections 30-43 and 31-210. Driveways on minor arterial streets
should be spaced 300-feet from other driveways and intersections and 150-feet from
the side property line. The width of driveway must not exceed 36-feet. A driveway
variance must be requested.
8. Show the location proposed gate controller. The controller must be located at least
60-feet from the Stagecoach Road curb.
Utilities and Fire Department/County Planning:
Wastewater: Sewer available to this project.
Entergy: Entergy does not object to this proposal. A 3-phase line exists in front of the
property with CATV attachments to the poles. Care should be taken to ensure
adequate clearance exists before moving large equipment or structures underneath the
lines. Contact Entergy in advance for service requirements and to determine locations
of required facilities.
Center -Point Energy: No comment received.
AT & T: No comment received.
Central Arkansas Water:
Item 4 13.
ITEM NO.: 13. Z-8978
1. All Central Arkansas Water requirements in effect at the time of request for water
service must be met.
2. A water main extension will be needed to provide water service to this property.
3. The Little Rock Fire Department needs to evaluate this site to determine whether
additional public and/or private fire hydrant(s) will be required. If additional fire
hydrant(s) are required, they will be installed at the Developer's expense.
4. Please submit plans for water facilities and/or fire protection system to Central
Arkansas Water for review. Plan revisions may be required after additional review.
Contact Central Arkansas Water regarding procedures for installation of water
facilities and/or fire service. Approval of plans by the Arkansas Department of
Health Engineering Division and the Little Rock Fire Department is required.
5. If there are facilities that need to be adjusted and/or relocated, contact Central
Arkansas Water. That work would be done at the expense of the developer.
6. Contact Central Arkansas Water if additional fire protection or metered water service
is required.
7. Due to the nature of this facility, installation of an approved reduced pressure zone
backflow preventer assembly (RPZA) is required on the domestic water service.
This assembly must be installed prior to the first point of use. Central Arkansas
Water requires that upon installation of the RPZA, successful tests of the assembly
must be completed by a Certified Assembly Tester licensed by the State of Arkansas
and approved by Central Arkansas Water. The test results must be sent to Central
Arkansas Water's Cross Connection Section within ten days of installation and
annually thereafter. Contact the Cross Connection Section at 501.377.1226 if you
would like to discuss backflow prevention requirements for this project.
8. The facilities on -site will be private. When meters are planned off private lines,
private facilities shall be installed to Central Arkansas Water's material and
construction specifications and installation will be inspected by an engineer, licensed
to practice in the State of Arkansas. Execution of Customer Owned Line agreement
is required.
9. Fire sprinkler systems which do not contain additives such as antifreeze shall be
isolated with a double detector check valve assembly. If additives are used, a
reduced pressure zone backflow preventer shall be required.
10. This development will have minor impact on the existing water distribution system.
Proposed water facilities will be sized to provide adequate pressure and fire
protection.
Fire Department: Fire hydrants per code, maintain access per code, drive lanes 24-
feet, gates 20-feet per code. Contact the Little Rock Fire Department for additional
information.
County Planning: No comment.
Item # 13.
ITEM NO.: 13. _ Z-8978
CATA: The area is currently served by CATA at this location by Route #23, Baseline
Southwest. While this location is in CATA's service area, the small single business unit
should not generate significant ridership so CATA only requests ADA compliant
sidewalks are required at this location.
Parks and Recreation: No comment received.
Building Code: Project is subject to full commercial plan review approval prior to
issuance of a building permit. For information on submittal requirements and the review
process, contact a commercial plans examiner: Curtis Richey at 501.371.4724;
crichey _littlerock.org or Mark Alderfer at 501.371.4875; malderfer _littlerock.orq.
Planninq Division: This request is located in the Otter Creek Planning District. The
Land Use Plan shows Service Trades District (STD) for this property. The Service
Trades District provides for a selection of office, warehousing, and industrial park
activities that primarily serve other office service or industrial businesses. The district is
intended to allow support services to these businesses and to provide for uses with an
office component. A Planned Zoning District is required for any development not wholly
office. The applicant has applied for a rezoning from R-2 (Single Family District) to PDC
(Planned District Commercial) to allow the construction of a mini -warehouse
development on this site.
Master Street Plan: Stagecoach Road is a Minor Arterial Street on the Master Street
Plan. A Minor Arterial provides connections to and through an urban area and their
primary function is to provide short distance travel within the urbanized area. Entrances
and exits should be limited to minimize negative effects of traffic and pedestrians on
Stagecoach Road. This street may require dedication of right-of-way and may require
street improvements for entrances and exits to the site.
Bicycle Plan: A Class II Bike Lane is shown along Stagecoach Road. Bike Lanes
provide a portion of the pavement for the sole use of bicycles.
Landscape:
1. Site plan must comply with the City's landscape and buffer ordinance requirements.
2. Street buffers will be required at six (6) percent of the average depth of the lot. The
minimum dimension shall be one-half (Y2) the full width requirement but in no case
less than nine (9) feet. Easements cannot count toward fulfilling this requirement.
The plantings, existing and purposed, shall be provided within the City's landscape
ordinance requirements.
a. The approximate average depth of the north tract is four hundred and ninety
(490) feet. An average thirty-nine foot (39) foot wide buffer is required along
Stagecoach Road.
Item # 13.
ITEM NO
WE
3. A land use buffer will be required when an adjacent property has a dissimilar use of
a more restrictive nature. As a component of all land use buffer requirements,
opaque screening, whether a fence or other device, a minimum of six (6) feet in
height shall be required upon the property line side of the buffer. A minimum of
seventy (70) percent of the land use buffer shall be undisturbed. Easements cannot
count toward fulfilling this requirement. The plantings, existing and purposed, shall
be provided within the landscape ordinance of the City, Section 15-81.
a. The property to the north is zoned C-2, Shopping Center District, the property
to the west and a portion of the property to the southwest are zoned PCD
therefore, (6% of the average lot width) a minimum seventeen (17) foot buffer
is required on the north property line, a minimum thirty-one (31) foot buffer is
required on the west property line and a minimum eleven (11) foot buffer is
required on the southwest property line.
4. A perimeter planting strip is required along any side of a vehicular use area that
abuts adjoining property. This strip shall be at least nine (9) feet wide. Provide trees
with an average linear spacing of not less than thirty (30) feet within the perimeter
planting strip. Provide three (3) shrubs or vines for every thirty (30) linear feet of
perimeter planting strip.
5. Landscape areas shall be provided between the vehicular use area used for public
parking and the general vicinity of the building, excluding truck loading or service
areas not open to public parking. These areas shall be equal to an equivalent planter
strip three (3) feet wide along the vehicular use area.
6. A landscape irrigation system shall be required for developments of one (1) acre or
larger.
7. The City Beautiful Commission recommends preserving as many existing trees as
feasible on this site. Credit toward fulfilling Landscape Ordinance requirements can
be given when preserving trees of six (6) inch caliper or larger.
Revised plat/plan: Submit four (4) copies of a revised preliminary plat/plan (to include
the additional information as noted above) to staff on Wednesday, October 15, 2014.
Item # 13.