Loading...
HomeMy WebLinkAboutZ-8871 Staff AnalysisITEM NO.: 13, Z-8871 NAME: K Lofts LLC, 315 Main Street Short -form PCD LOCATION: located at 315 Main Street Planning Staff Comments_ 1. Provide notification of the property owners located within 200-feet of the site, including the certified abstract list, notice form with affidavit executed and proof of mailing. The notice must be mailed no later than June 26, 2013. The Office of Planning and Development must receive the proof of notice no later than July 5, 2013. 2. Lighting is to be placed so as to reflect away from adjacent residential structures. Fixtures adjacent to roadways shall be of a design that minimizes glare to the motoring public. 3. All ground mounted mechanical systems and trash receptacles and pickup shall be oriented away from a primary street side of the property and screened from the public right of way. Ground mounted mechanical systems and trash receptacles shall be placed adjacent to alleys if alleys are available. 4. Street trees a minimum of three inch caliper shall be required. The trees shall be located a minimum of 2-feet off the back of curb and 30-feet on center and no closer than 30-feet to a street intersection with a water source provided. Tree canopy shall be maintained at least 8-feet above the sidewalk. 5. The ground level (street fronting) floor of nonresidential structures shall have a minimum surface area of 60 percent transparent or window display. 6. Objects shall not project from the building fagade over the public right of way except for awnings, balconies and signs as specified in Section 36-553. Awnings shall not project more than 5-feet from the building fagade and have a minimum clearance of 8-feet above the sidewalk. Balconies over the public right of way shall have a minimum clearance of 9-feet above the sidewalk. The maximum projection shall be 4-feet. 7. Building signage is allowed as permitted in institutional and office zones. On the street level, the maximum area of signage may be doubled if at least 50 percent of the street level office and retail space has direct access to the street. Ground signs are discouraged but may be permitted as a variance. 8. Will the units be maintained or will the units/suites be sold as condo units? 9. Will there be space available for a food store under 5,000 square feet which may sell beer or wine? 10. Special Events Center, Montego Cafe - a. The Zoning Board of Adjustment recently approved a request to allow outdoor dining within the right of way. b. The request includes the allowance of the basement level as a special events center. c. It appears the center will operate as a private club. The hours are indicated until 2AM seven days per week. Item # 13. d. Will the restaurant provide food service to the special events center activities? e. Will both the restaurant and the special events center be open during the same hours? 11.It appears the uses proposed are the uses allowed in the UU, Urban Use Zoning District. The request is to allow an increase in the overall density of the residential from 72 units per acre to 200 units per acre. Variance/Waivers: None requested. Public Works Conditions: 1. Repair or replace any curb and gutter or sidewalk that is damaged in the public right- of-way prior to occupancy. 2. The proposed patio has been approved by the Board of Adjustments with conditions. Staff is currently processing a franchise permit for the patio. The drawing attached to the application does not show the approved patio setbacks. Utilities and Fire Department/County Planning: Wastewater: Sewer available to this project. Capacity Contribution Fee Calculation required. Contact Little Rock Wastewater for additional information. Entergy: No comment received. Center -Point Energy: No comment received. AT & T: No comment received. Central Arkansas Water: 1. No objections. All Central Arkansas Water requirements in effect at the time of request for water service must be met. 2. Contact Central Arkansas Water regarding the size and location of the water meter. 3. If there are facilities that need to be adjusted and/or relocated, contact Central Arkansas Water. That work would be done at the expense of the developer. 4. Contact Central Arkansas Water if additional fire protection or metered water service is required. 5. The Little Rock Fire Department needs to evaluate this site to determine whether additional public or private fire hydrant(s) will be required. If additional fire hydrant(s) are required, they will be installed at the Developer's expense. 6. Due to the nature of this facility, installation of an approved reduced pressure zone backflow preventer assembly (RPZA) is required on the domestic water service. This assembly must be installed prior to the first point of use. Central Arkansas Water requires that upon installation of the RPZA, successful tests of the assembly must be completed by a Certified Assembly Tester licensed by the State of Arkansas and approved by Central Arkansas Water. The test results must be sent to Central Arkansas Water's Cross Connection Section within ten days of installation and Item # 13. annually thereafter. Contact the Cross Connection Section at 377-1226 if you would like to discuss backflow prevention requirements for this project. Fire Department: Place fire hydrant(s) per code. Maintain access. Contact the Little Rock Fire Department for additional information. County Planning: No comment. CATA: Approved as submitted Parks and Recreation: No comment. Planning Division: This request is located in the Downtown Planning District. The Land Use Plan shows Mixed Use Urban (MXU) for this property. The Mixed Use Urban category provides for a mix of residential, office and commercial uses not only in the same block but also within the same structure. This category is intended for older "urban" areas to allow dissimilar uses to exist, which support each other to create a vital area. Development should reinforce the urban fabric creating a 24-hour activity area. Using the Planned Zoning District or the Urban Use District, high and moderate density developments that result in a vital (dense) pedestrian oriented area are appropriate. The applicant has applied for a rezoning from UU (Urban Use District) to PCD (Planned Commercial District) to a higher density of residential than normally within this mixed - use development. Master Street Plan: Main Street is a Minor Arterial on the Master Street Plan. A Minor Arterial provides connections to and through an urban area and their primary function is to provide short distance travel within the urbanized area. Entrances and exits should be limited to minimize negative effects of traffic and pedestrians on Main Street since it is a Minor Arterial. This street may require dedication of right-of-way and may require street improvements for entrances and exits to the site. Bicycle Plan: There is a Class III Bike Route shown along Main Street. Bike Routes require no additional right-of-way or pavement markings, but only a sign to identify and direct the route. Landscape: 1. Site plan must comply with the City's landscape and buffer ordinance requirements. 2. The scale is not 1 "=30'; the sketch for the franchise application reflects a patio along the next lot; therefore, street trees for both lots will need to be in compliancy and included with this application. 3. Per the UU district standards street trees must be installed with this application, which will include automatic irrigation and tree grates. If there are currently trees within this area they must be in good condition or replaced as a part of this application. 4. Any additional parking must be landscaped in accordance to Chapter 15 of the Landscape Ordinance, City of Little Rock. It will require additional review and approval from the Planning Department. Item # 13. Revised_plat/plan: Submit four (4) copies of a revised preliminary plat/plan (to include the additional information as noted above) to staff on Wednesday, June 26, 2013. Item # 13. FILE NO.: Z-8871 NAME: K Lofts LLC, 315 Main Street Short -form PCD LOCATION: Located at 315 Main Street DEVELOPER: Scott Reed & K Lofts LLC 1001 SW 5th Avenue, Suite 1100 Portland, OR 97204 ENGINEER: Paul D. Fleming, PE SECB 18 Essay Drive Little Rock, AR 72223-9142 AREA: 7,024 Sq. Ft. CURRENT ZONING: ALLOWED USES: NUMBER OF LOTS: 1 zoning lot UU, Urban Use District Residential, Office, Commercial PROPOSED ZONING: PCD FT. NEW STREET: 0 LF PROPOSED USE: Allow multi -family density at a rate greater than the UU Zoning District and allow a private club VARIANCES/WAIVERS REQUESTED: None requested. A. PROPOSAL/REQUEST/APPLICANT'S STATEMENT: The owners of K Lofts LLC a registered Limited Liability Corporation in the State of Arkansas, are applying for a change in the zoning status for the property commonly known as 315 Main Street located in Little Rock, Arkansas and previously known as the Gus Blass Wholesale Company Building. Presently at the property the bottom two floors are retail containing a completely rehabbed space under the operation of Montego's Cafe. This popular site operates during the week and weekend and has become a destination for both food and live music. FILE NO.: Z-8871 (Copt. The property is presently zoned UU, Urban Use District. The current plan for the upper stories of this historic building are 32 apartments spread out over 5 floors. The property will have a completely updated and modern sprinkler and fire system, elevators, new stairs serving the entire building and modern apartment units with a host of upgraded amenities for the tenants within the property. Parking while not required under the UU zoning will be provided at the 2"d Street parking deck a block away from the property for tenants. Density limits for apartments in the UU Zoning District are 72 units per acre of land. The property land area is approximately 7,000 square feet, which would only allow the development of 12 units. The applicant is applying for a more dense multi -family development to allow 32 residential units and one commercial unit within the 5-story building. To allow the density desired the applicant is proposing a rezoning to PCD maintaining the UU, Urban Use District uses as allowable uses for the property - The request also includes the allowance of a private club within the building. Montego Cafe plans to provide a full service restaurant offering lunch, dinner and/or brunch seven days per week. The Cafe also offers live music, dance hall and an entertainment venue. The business will be open until 2:00 AM seven days per week. B. EXISTING CONDITIONS The UU zoned property at 315 Main Street is occupied by a five -story commercial building. The first floor of the building contains a restaurant, Montego Cafe. On April 29, 2013, the Zoning Board of Adjustment approved a request to allow the restaurant to create an outdoor dining area on the west (Main Street) side of the building. C. NEIGHBORHOOD COMMENTS: As of this writing, staff has not received any comment from area residents. All property owners located within 200-feet of the site along with the Downtown Neighborhood Association, the MacArthur Park Neighborhood Association and the River Market Neighborhood Association were notified of the public hearing. D. ENGINEERING COMMENTS: PUBLIC WORKS CONDITIONS: 1. Repair or replace any curb and gutter or sidewalk that is damaged in the public right-of-way prior to occupancy. 2. The proposed patio has been approved by the Board of Adjustments with conditions. Staff is currently processing a franchise permit for the patio. The drawing attached to the application does not show the approved patio setbacks. 2 FILE NO.: Z-8871 (Cont.) E. UTILITIES AND FIRE DEPARTMENT/COUNTY PLANNING: Wastewater: Sewer available to this project. Capacity Contribution Fee Calculation required. Contact Little Rock Wastewater for additional information. Entergy: No comment received. Center -Point Energy: No comment received. AT & T: No comment received. Central Arkansas Water: 1. No objections. All Central Arkansas Water requirements in effect at the time of request for water service must be met. 2. Contact Central Arkansas Water regarding the size and location of the water meter. 3. If there are facilities that need to be adjusted and/or relocated, contact Central Arkansas Water. That work would be done at the expense of the developer. 4. Contact Central Arkansas Water if additional fire protection or metered water service is required. 5. The Little Rock Fire Department needs to evaluate this site to determine whether additional public or private fire hydrant(s) will be required. If additional fire hydrant(s) are required, they will be installed at the Developer's expense. 6. Due to the nature of this facility, installation of an approved reduced pressure zone backflow preventer assembly (RPZA) is required on the domestic water service. This assembly must be installed prior to the first point of use. Central Arkansas Water requires that upon installation of the RPZA, successful tests of the assembly must be completed by a Certified Assembly Tester licensed by the State of Arkansas and approved by Central Arkansas Water. The test results must be sent to Central Arkansas Water's Cross Connection Section within ten days of installation and annually thereafter. Contact the Cross Connection Section at 377-1226 if you would like to discuss backflow prevention requirements for this project. Fire Department: Place fire hydrant(s) per code. Maintain access. Contact the Little Rock Fire Department for additional information. County Planning: No comment. CATA: Approved as submitted Parks and Recreation: No comment. 3 FILE NO.: Z-8871 (Cont.) F. ISSUES/TECHNICAL/DESIGN: Planning Division: This request is located in the Downtown Planning District. The Land Use Plan shows Mixed Use Urban (MXU) for this property. The Mixed Use Urban category provides for a mix of residential, office and commercial uses not only in the same block but also within the same structure. This category is intended for older "urban" areas to allow dissimilar uses to exist, which support each other to create a vital area. Development should reinforce the urban fabric creating a 24-hour activity area. Using the Planned Zoning District or the Urban Use District, high and moderate density developments that result in a vital (dense) pedestrian oriented area are appropriate. The applicant has applied for a rezoning from UU (Urban Use District) to PCD (Planned Commercial District) to a higher density of residential than normally within this mixed -use development. Master Street Plan: Main Street is a Minor Arterial on the Master Street Plan. A Minor Arterial provides connections to and through an urban area and their primary function is to provide short distance travel within the urbanized area. Entrances and exits should be limited to minimize negative effects of traffic and pedestrians on Main Street since it is a Minor Arterial. This street may require dedication of right-of-way and may require street improvements for entrances and exits to the site. Bicycle Plan: There is a Class III Bike Route shown along Main Street. Bike Routes require no additional right-of-way or pavement markings, but only a sign to identify and direct the route. Landscape: 1. Site plan must comply with the City's landscape and buffer ordinance requirements. 2. The scale is not 1 "=30'; the sketch for the franchise application reflects a patio along the next lot; therefore, street trees for both lots will need to be in compliancy and included with this application. 3. Per the UU district standards street trees must be installed with this application, which will include automatic irrigation and tree grates. If there are currently trees within this area they must be in good condition or replaced as a part of this application. 4. Any additional parking must be landscaped in accordance to Chapter 15 of the Landscape Ordinance, City of Little Rock. It will require additional review and approval from the Planning Department. G. SUBDIVISION COMMITTEE COMMENT: (June 20, 2013) The applicants were present. Staff presented an overview of the proposed development questioning several aspects of the development. Staff questioned if there would be a food store less than 5,000 square feet selling beer or wine. E FILE NO.: Z-8871 Staff also questioned if request was for a private club or a special events center. The applicant stated the restaurant would operate as a private club. He stated the reason for the private club license through the Alcohol Beverage Control was to allow the business to remain open until 2 am seven days per week. He stated there would be live music and dancing would be allowed on -site. He stated the restaurant and the private club would operate during the same hours. Staff noted street trees would be required with the proposed redevelopment. The applicant stated this area of Main Street was to be redeveloped with landscaping, hardscaping and rain gardens by the City with grant funds. Staff noted comments from the other reporting departments and agencies suggesting the applicant contact them individually for additional clarification. There was no further discussion of the item. The Committee then forwarded the item to the full Commission for final action. H. ANALYSIS: The applicant submitted revised comments to staff addressing concerns raised at the June 20, 2013, Subdivision Committee meeting. The applicant has indicated there will not be a food store less than 5,000 square feet selling beer or wine. The applicant has also indicated the units will be maintained as rental and will not be sold. The applicant is requesting to maintain the UU, Urban Use Zoning District uses as allowable uses for the property. The applicant has indicated the restaurant user will have outdoor dining within the public right of way as approved by the Zoning Board of Adjustment. The applicant is seeking approval of a PCD zoning for the Gus Blass Wholesale Company Building located at 315 Main Street. Presently Montego's Cafe is occupying the basement and main level of the building. The request would allow the upper floors to be rehabbed into 32 apartments spread out over 5 floors. Within the 2"d floor tenant space will be reserved for flex space to allow small office or retail users. The requested rezoning to PCD will allow for additional density in the upper floors for apartments. The property contains 7,000 square feet and is proposed for development of up to 32 unit which results in a density for the site of 200 units per acre. The UU, Urban Use Zoning District allows for development of multi -family at a density of 72 units per acre. Within the UU, Urban Use Zoning District no off-street parking is required. Parking, while not required under the UU zoning, will be provided at the 2"d Street parking deck a block away from the property for tenants. The request also includes the allowance of a private club within the building. Montego Cafe plans to provide a full service restaurant offering lunch, dinner and/or brunch seven days per week. The Cafe also offers live music, dance hall 5 FILE NO.: Z-8871 (Cant. and an entertainment venue. The approval of the private club would allow the restaurant to be open until 2:00 AM seven days per week. The applicant has indicated lighting, will be placed so as to reflect away from adjacent residential structures. The fixtures adjacent to the roadways will be designed to minimize glare to the motoring public. Signage will comply with signage allowed within the UU, Urban Use Zoning District. The applicant does not anticipate the placement of ground signage with the redevelopment of the site. Section 36-342.1 states objects shall not project from the building fagade over the public right of way except for awnings, balconies and signs as specified in Section 36-553. Awnings shall not project more than 5-feet from the building fagade and have a minimum clearance of 8-feet above the sidewalk. Balconies over the public right of way shall have a minimum clearance of 9-feet above the sidewalk. The maximum projection shall be 4-feet. The applicant has indicated no new projections or awnings will be added to the building. Section 36-342.1 states street trees a minimum of three inch caliper shall be required. The trees shall be located a minimum of 2-feet off the back of curb and 30-feet on center and no closer than 30-feet to a street intersection with a water source provided. Tree canopy shall be maintained at least 8-feet above the sidewalk. The applicant has indicated they will work with the City in developing the streetscape for this area. Staff is supportive of the request. Staff does not feel the rezoning to PCD to allow an increase in the allowable density of multi -family for this site will adversely impact the area. Staff is also supportive of the allowance of a private club to allow the restaurant user located on the site to operate until 2:00 am seven days per week. To staff's knowledge there are no remaining outstanding technical issues associated with the request. STAFF RECOMMENDATIO Staff recommends approval of the request subject to compliance with the comments and conditions as outlined in paragraphs D, E and F of the agenda staff report. PLANNING COMMISSION ACTION: (JULY 11, 2013) The applicant was present. There were no registered objectors present. Staff presented the item with a recommendation of approval of the request subject to compliance with the comments and conditions as outlined in paragraphs D, E and F of the agenda staff report. A FILE NO.: Z-8871 Cont. There was no further discussion of the item. The chair entertained a motion for approval of the item as presented by staff. The motion carried by a vote of 9 ayes, 0 noes and 2 absent. 7