HomeMy WebLinkAboutZ-8852 MapSITE NAME: AIRPORT - WILSON INN ,
Sprint
SITE NU
MBER: LR03XCO04 2 - �a-
6580 SPRINT PARKWAY
STRUCTURE TYPE: ROOFTOP OVERLAND PARK. KANSAS 86251
•
Sprin
MARKET: ARKANSAS
I, 3 ERICSSON
NETWORK VISION MMBS LAUNCH !'tNYd�i;`",`dlr : �= f E L �� 610DPARK, AIISISPARKWAY
4 OVERLAND PAR(, KANSAS 86251
Gad 11", LAN V:'�.'.:;DS _tl tl its c`ERI'J11414
PROJECT SUMMARY DRIVING DIRECTIONS VICINITY MAP LIST OF DRAWINGS ■ ssc
SHEET TITLE RESP ENGR
SITE NAME: AIRPORT - WILSON INN DEPART FROM: 9900 West 1091h Street, Suite 300
FROM THE HIGHWAY INTERCHANGE AT 1-530 & 1-440, IN T-1 TITLE SHEET MLO/TMS Ovedand Pads, Kansas 66210
SITE NUMBER: LR03XCO04 LITTLE ROCK, ARKANSAS. MERGE ONTO 1-440 E TOWARD
SITE ADDRESS: 4301 E ROOSEVELT RD L.R. NATIONAL AIRPORT/L.R. RIVER PORT/MEMPHIS (3.0 MI). � ? Phone: 913-03&7700 Fax: 91343&7777
LITTLE ROCK, ARKANSAS 72201 TAKE EXIT 3 FOR BANKHEAD OR TOWARD L.R. NATIONAL PROJECT fe�A-1 OVERALL SITE LAYOUT MLO
AIRPORT (0.2 MI). KEEP LEFT AT THE FORK, FOLLOW SIGNS LOCATION X_ A-2 EQUIPMENT LAYOUTS MLO
APNL: FOR L.R. AIRPORT (118 FT). TURN LEFT ONTO BANKHEAD A-3 EQUIPMENT
MENT LAYS MLO
DR (0.4 MI), CONTINUE ONTO AIRPORT RD (413 FT).SITELATITUDE: N 34' 43' 14.87- N (NAD 83) DESTINATION WILL BE ON THE RIGHT, E Roosewd-Rd -
A-4 ANTENNA PLANS MLO
fm MLO
LONGITUDE: W 92' 13' 36.84" (NAD 83) Littlr Rock 1A10� at. A-6 RFDS SHEET (V82, 09/26/12)
GROUND ELEVATION: 253' AMSL) ( � A-7 PLUMBING DIAGRAMS MLO
JURISDICTION: PULASKI COUNTY
� A-8 COLOR CODING DETAILS MLO
ZONING: N/A A-9 DETAILS MLO
A STATE OF ARKANSAS
-10 DETAILS MLO
CERTIFICATE OF AUTHORIZATION ffn4
A-11 DETAILS MILO RESPOMBLEE10NI CRS
4 '•'^-� �- MLO MICHAELL OWENS 13455 STRUCTURAUCML
SCOPE OF WORK- TMS TERRANCE M SUPER 9717 ELECTRICAL
E-1 UTILITY SITE PLAN TMS
1. THE WIRELESS COMMUNICATION FACILITY IS NOT INTENDED FOR ~` - -.}-eve E-2 DETAILS TMS
HUMAN OCCUPANCY _ t TL1S NOTICE THIS DRAWING HAS NOT BEEN PUBLISHED AND IS THE
E-3 DETAILS
�]. SOLE PROPERTY OF SSC, INC AND IS LENT TO THE BORROWER
2. THIS FACILITY DOES NOT REQUIRE PORTABLE WATER AND WILL �� SjMFWa E-4 GROUNDING PLAN. RISER AND NOTES TMS FOR THEIR CONFIDENTIAL USE ONLY, AND IN CONSIDERATION
OF THE LOAN OF THIS DRAWING, THE BORROWER PROMISES
NOT PRODUCE ANY SEWAGE AND AGREES TO RETURN IT UPON REQUEST AND AGREES THAT
E-5 DETAILS TMS IT
WILL NOT BE REPRODUCED, COPIED, LENT OR OTHERWISE
DISPOSED OF DIRECTLY OR INDIRECTLY, NOR USED FOR ANY
WIRELESS INSTAL
3. THE SCOPE OF WORK CONSISTS OF MODIFYINGNG THE EXISTING CONTACTS APPROVALS E-6 DETAILS TMS PURPOSE OTHER THAN FOR WHICHITISFURNINSTALLATION:
DESIGNER: TN TAYLOR
REMOVAL OF (3) EXISTING EQUIPMENT CABINETS APPLICANT: SPRINT PCS GN-1 GENERAL NOTES MLO/TMS
INSTALLATION OF (2) NEW EQUIPMENT CABINETS 6580 SPRINT PARKWAY
LEAD EE: T. SUPER
REMOVAL OF (6) EXISTING ANTENNAS OVERLAND PARK, KS 66251
INSTALLATION OF (3) NEW ANTENNAS LEAD CFJSE: M. OvvENs
INSTALLATION OF (9) NEW RRU'S (REMOTE RADIO UNITS) SPRINT REPRESENTATIVE DATE
19WER/PROPERTY OWNER; SUN GEMDEVELOPMENTCORPORATION NO. GATE SUBMITTALS
DESCRIPTION 1 BY
5701 PROGRESS ROAD
INDIANAPOLIS, IN 46241 SPRINT RF ENGINEERING DATE A 9FJTFG4IaEXix
i11d61i2 15TNf
APPLICABLE CODES ENGINEERING CONSULTANTS: SSC, INC.
ssoo w tosTH sr, SUITE 300
OVERLAND PARK, KS 66210 SITE OWNER DATE
VIN
ALL WORK SHALL BE PERFORMED AND MATERIALS INSTALLED IN ACCORDANCE HEL VAN EISLE S
WITH THE CURRENT EDITIONS OF THE FOLLOWING CODES AS ADOPTED BY THE HELTON KISLING SITE NAME
LOCAL GOVERNING AUTHORITIES. NOTHING IN THESE PLANS IS TO BE (913) 430-7700
CONSTRUED TO PERMIT WORK NOT CONFORMING TO THESE CODES. : KATHY BYRD SPRINT CONSTRUCTION MANAGER DATE AIRPORT - WILSON M
ERICSSON
1. INTERNATIONAL BUILDING CODE 6100 SPRINT PARKWAY
2. INTERNATIONAL MECHANICAL CODE OVERLAND PARK, KSA 66251 THE ABOVE PARTIES HEREBY APPROVE AND ACCEPT THESE DOCUMENTS AND
/TIA-222 STRUCTURAL STANDARD (913) 223-1206 AUTHORIZE CONTRACTOR TO PROCEED WITH THE CONSTRUCTION DESCRIBED
3. ANSI
4. ANSINFP780 -LIGHTNING PROTECTION CODE HEREIN. ALL DOCUMENTS ARE SUBJECT TO REVIEW BY THE LOCAL BUILDING SITE NUMBER
5. UNIFORM PLUMBING CODE SM: JOHNNY ATWOOD DEPARTMENT AND MAY IMPOSE CHANGES OR MODIFICATIONS. LR03XCO04
6. NATIONAL ELECTRICAL CODE (501) 574-1269 SITE ACCESS PROCEDURES ENGINEER'S LICENSE
RF ENGINEER: SAJID HAMID SPRINT MARKED WITH BLACK & YELLOW TAPE COMBINATION LOCKS: 6985 SITE ADDRESS
CALL BEFORE YOU (214) 538-9864 4301 E ROOSEVELT RD
DIG — DRILL — BLAST ALL CABINET COMBINATION LOCKS: 6985 LITTLE ROCK, ARKANSAS
1-800-482-8998 72201
(TOLL FREE) FIBER PROVIDER:
ARKANSAS ONE -CALL SYSTEM, INC. SHEETTITLE
THE UTILITIES AS SHOWN ON THIS SET OF DRAWINGS WERE DEVELOPED
TITLE SHEET
FROM THE INFORMATION AVAILABLE. THE INFORMATION PROVIDED POWER PROVIDER:
IS NOT IMPLIED NOR INTENDED TO BE THE COMPLETE INVENTORY
OF UTILITIES IN THIS AREA. IT IS THE CONTRACTOR'S RESPONSIBILITY
TO VERIFY THE LOCATION OF ,6l UTILITIES (WHETHER SHOWN OR NOT) SHEET NUMBER
AND PROTECT SAID UTILITIES FROM ANY DAMAGE CAUSED BY
CONTRACTOR'S ACTIVITIES. T _ 1
ABBREVIATIONS
AFF
ABOVE FINISHED FLOOR
AGL
ABOVE GRADE LEVEL
AMSL
ABOVE MAIN SEA LEVEL
APPROX
APPROXIMATE
AWG
AMERICAN WIRE GAUGE
BLDG
BUILDING
BTS
BASE TRANSMISSION STATION
CLR
CLEAR
COL
COLUMN
CONC
CONCRETE
CND
CONDUIT
DWG
DRAWING
FT
FOOT (FEET)
EGB
EQUIPMENT GROUND BAR
ELEC
ELECTRICAL
EMT
ELECTRICAL METALLIC TUBING
ELEV
ELEVATION
EQUIP
EQUIPMENT
(E)
EXISTING
EXT
EXTERIOR
FND
FOUNDATION
F
FIBER
GA
GAUGE
GALV
GALVANIZED
GPS
GLOBAL POSITIONING SYSTEM
GND
GROUND
LTE
LONG TERM EVOLUTION
MAX
MAXIMUM
MFR
MANUFACTURER
MGB
MASTER GROUND BAR
MIN
MINIMUM
MMBTS
MULTI -NODE BASE
TRANSMISSION STATION
N.T.S.
NOT TO SCALE
O.C.
ON CENTER
OE/OT
OVERHEAD ELECTRIC/TELCO
PPC
POWER PROTECTION CABINET
RBS
RADIO BASED STATION
RRU
REMOTE RADIO UNIT
RGS
RIGID GALVANIZED STEEL
IN
INCH(ES)
INT
INTERIOR
LB(S)
POUND(S)
SF
SQUARE FOOT
STL
STEEL
TYP
TYPICAL
UE/UT
UNDERGROUND ELECTRIC/TELCO
UNO
UNLESS NOTED OTHERWISE
VIF
VERIFY IN FIELD
W/
WITH
XFMR
TRANSFORMER
#
POUND(S)
SYMBOLS
REVISION
WORK POINT
0
UTILITY POLE
®
WALL
COMPRESSED STONE
a
CONCRETE/GRAVEL
ASPHALT
EARTH
GRATING
— - — - — - —
STEEL
CENTERLINE
--------
PROPERTY LINE
LEASE LINE
- - - - - - - - -
EASEMENT LINE
CHAIN LINK FENCE
-�--�o-
WOOD FENCE
BELOW GRADE
ELECTRIC
BELOW GRADE
TELEPHONE
-OHP—OHP—
OVERHEAD
ELECTRIC/TELEPHONE
Al
SECTION REFERENCE
EXISTING
EQUIPMENT AREA
4a
NORTH
0' 4' 8' 16, 24'
Sprint )1�
6560 SPRINT PARKWAY
OVERLAND PARK, KANSAS GM1
409
Rom
PIP
ERICSSON
6100 SPRINT PARKWAY
MLW PAW. KANSA5 6625t
14
44 SSC
9900 west 1091h Street, Suite 300
Overland Park, Kanses66210
Phone: 913-03&7700 Fan: 913-436-7T77
STATE OF ARKANSAS
CERTIFICATE OF AUTHORIZATON 0774
RESPONSIBLE ENGINEERS:
MLO MICHAELL OWENS 13450 STRUCTURAUCIVIL
TMS TERRANCE M SUPER 9717 ELECTRICAL
NOTICE: THIS DRAWING HAS NOT BEEN PUBLISHED AND IS THE
SOLE PROPERTY OF SSC, INC AND IS LENT TO THE BORROWER
FOR THEIR CONFIDENTIAL USE ONLY, AND IN CONSIDERATION
OF THE LOAN OF THIS DRAWING, THE BORROWER PROMISES
AND AGREES TO RETURN IT UPON REQUEST AND AGREES THAT
IT WILL NOT BE REPRODUCED, COPIED, LENT OR OTHERWISE
DISPOSED OF DIRECTLY OR INDIRECTLY, NOR USED FOR ANY
PURPOSE OTHER THAN FOR WHICH IT IS FURNISHED
I DESIGNER: T.N. TAYLOR II
LEAD EE: T. SUPER
LEAD CEISE: M. OWENS
SUBMITTALS
rll
SITE NAME
AIRPORT - WILSON INN
SITE NUMBER
LR03XCO04
SITE ADDRESS
4301 E ROOSEVELT RD
LITTLE ROCK, ARKANSAS
72201
SHEET TITLE
OVERALL SITE PLAN
SHEET NUMBER
A-1
OVERALL SITE PLAN
F'. EXISTING
CABLE TRAY
1 .
EXISTING
CONCRETE
PAD
EMPTY SPACE
ON SLED
PLATFORM (TYP)
EXISTING EXISTING
—6'X 2'-6 3'-6'X 2'-6'
SPRINT SPRINT
CABINET CABINET
EXISTING
3'-0"X 2'-6"
SPRINT
CABINET EXISTING
EXISTING
PPC RACK
WOOD FENCE,,
`
EXISTING
METER
EXISTING
BREAKER BOX
EXISTING
TELCO BOX —
NORTH
EXISTING EQUIPMENT LAYOUT 13
EMPTY SPACE
ON SLED
PLATFORM (ll
EXISTING
WOOD FENCE
EMPTY SPACE
ON SLED
PLATFORM (I1
EXISTING
WOOD FENCE
EXISTING
EXISTING
—6'X 2'—B"
—6"x 2'� G
SPRINT
SPRINT
CABINET
CABINET
EXISTING
PPC RACK
EXISTING
TELCO BOX
EXISTING (3) SPRINT CABINETS TO BE
REMOVED AFTER NEW CABINET INSTALLATION
HAS BEEN TESTED AND APPROVED BY
PROJECT MANAGER
EXISTING
3'-0"X 2'-6"
SPRINT
CABINET
TEMPORARY EQUIPMENT LAYOUT
FINAL EQUIPMENT LAYOUT
■
Sprint
'*
6580 SPRINT PARKWAY
OVERLAND PARK, KANSAS 662S1
409
4F.mp
ERICSSON
6100 SPRINT PARKWAY
OVQ M PARK KANSAS 66251
[4 14
SSC
9900 West 109th street, Suile 300
Ovedand Park, Kansas66210
Phone: 913436:7700 Fax: 913-030-7777
STATE OF ARKANSAS
C ERTIFICATE OF AUTHORIZATION M4
RESPONSIBLE ENGINEERS:
NORTH TMS TERRANCE M SUPER 97173456
717 ELECTRICAL L
NOTICE: THIS DRAWING HAS NOT BEEN PUBUSHEDAND IS THE
SOLE PROPERTY OF SSC, INC AND IS LENT TO THE BORROWER
FOR THEIR CONFIDENTIAL USE ONLY, AND IN CONSIDERATION
OF THE LOAN OF THIS DRAWING, THE BORROWER PROMISES
AND AGREES TO RETURN IT UPON REOUESTAND AGREES THAT
IT WILL NOT BE REPRODUCED, COPIED, LENT OR OTHERWISE
DISPOSED OF DIRECTLY OR INDIRECTLY, NOR USED FOR ANY
PURPOSE OTHER THAN FOR WHICH IT IS FURNISHED
DESIGNER: T.N- TAYLOR
LEAD EE: T. SUPER
LEAD CEISE: M. OWENS
SUBMITTALS
NORTH
NO.
I DATE
DESCRIPTION
BY
A
it
651ED FOR REPO N
TNT
SITE NAME
AIRPORT - WILSON INN
SITE NUMBER
LR03XCO04
SITE ADDRESS
4301 E ROOSEVELT RD
LITTLE ROCK, ARKANSAS
72201
SHEET TITLE
EQUIPMENT LAYOUTS
SHEET NUMBER
A-2
SSC HAS NOT PERFORMED A STRUCTURAL TOWER INa ROTES:
NOTES:
ANALYSIS AND HAS NOT BEEN PROVIDED ANY STRUCTURAL 1. THE SIZE, HEIGHT, AND DIRECTION OF THE ANTENNA
1.
CONTRACTOR TO FIELD VERIFY ANTENNA CABLE
TOWER ANALYSIS INFORMATION REGARDING THIS SITE, SHALL BE ADJUSTED TO MEET SYSTEM REQUIREMENTS.
RRIFY HEIGHT OF ANTENNA WITH
2 CONTRACTORVERIFY
2.
LENGTHS.
ALL MAIN CABLES WILL BE COLOR CODED AT THREE
Sprint
RF STGNAGEc REP REPRESENTATIVE
PENDING ANTENNA
(3) LOCATIONS.
MOUNT CE"FiCATION SITE HAS EXISTING RF SIGNAGE 3. ALL ANTENNA AZIMUTHS TO BE TAKEN FROM TRUE NORTH.
3.
COLOR CODE ALL ANTENNA AND COAX WITH 2" WIDE
6580 SPRINT PARKWAY
OVERLAND PARK, KANSAS 66251
BANDS OF COLORED TAPE WITH 1" SEPARATION
BETWEEN BANDS - SEE SHEET A-7.
4.
COLOR CODE ALL TOP AND BOTTOM GROUND KITS
WITH 1" WIDE BANDS OF COLORED TAPE WITH 1/2"
409
SEPARATION BETWEEN BANDS.
PC
SPRINT PANTED
5.
6.
START COLOR BANDS 2" BEYOND WEATHERPROOFING.
START SECTOR COLOR NEXT TO END CONNECTOR.
ERICO
L OF PROPOSE[] SPRINT ANTENNAS
'S, (3) A2 » r-
PROPOSED (9) RRUC
7.
ALL MAIN CABLES WILL BE GROUNDED W/ COAXIAL
CABLE GROUND KITS AT:
61DO SPRINT PARKWAY
OVcRLAND PARK, KANSAS 66251
MODULES 8 (3) FILTERS ELEV. fu-O
THE ANTENNA LEVEL
MOUNTED ON BUILDING WALL CL OF EXISTING SPRINT ANTENNAS
I� ELEV. 58'-O"
MID LEVEL IF TOWER IS OVER 200'
BASE OF TOWER PRIOR TO TURNING HORIZONTAL
JUMPERS
44
(6) EXISTING SPRINT ANTENNAS TO BE
TERMINATION OF COAX LINES TO
;14
RELOCATED AND THEN REMOVED WHEN
ALL NEW GROUND BAR DOWNLEADS ARE TO BE
EQUIPMENT MIGRA
(SEE DETAILS SHT
I
I
1
n
II
TION IS FINISHED 6'
A-4 & A-5) GADWELDED TO THE EISADJACENT GROUND BAR
DOWNLEADS A MINIMUMM DISTANCE OF 4' BELOW
GROUND BAR.
ssoo west msln sveel, sae ao0
9. PROVIDE BUSS BAR NEAR BTS FOR ATTACHMENT OF Overland Park, Kansas 66210
WiMAX COAX GROUND KITS. Phone:slaa38-n00 Fm:913438-7777
COAXIAL A T NNA CABLE .NOTES:
1. THE ANTENNA COAXIAL CABLE INSTALLER SHALL BE
RESPONSIBLE FOR PERFORMING AND SUPPLYING
SPRINT WITH 3 TYPEWRITTEN SWEEP TESTS (ANTENNA
RETURN LOSS TEST). THIS TEST SHALL BE
PERFORMED TO THE SPECIFICATIONS AND PARAMETERS
OUTLINED BY THE SPRINT RADIO FREQUENCY (RF)
ENGINEER. THIS TEST SHALL BE PERFORMED PRIOR
TO FINAL ACCEPTANCE OF THE SITE.
2. THE ANTENNA COAXIAL CABLE INSTALLER SHALL BE
(2j PROPOSED SPRINT
CABINETS LOCATED IN
EQUIPMENT AREA
SITE ELEVATION
(WEST)
3.
4.
5.
6.
2
RESPONSIBLE FOR PERFORMING AND SUPPLYING
SPRINT WITH 3 TYPEWRITTEN TIME DOMAIN
REFLECTOMETER (MR) TESTS TO VERIFY CABLE
LENGTH AND TO CHECK FOR WATER DAMAGE.
VAPOR WRAP WILL BE USED TO SEAL ALL
CONNECTIONS.
ALL JUMPERS TO THE ANTENNAS FROM THE MAIN
TRANSMISSION LINE WILL BE 1/2" JUMPERS AT WiMAX
BTS UNITS WILL BE W-07.
IF COAX IS BEING RE -USED FOR THIS INSTALLATION,
PRE AND POSE ANTENNA LINE SWEEPS ARE
REQUIRED.
UPON COMPLETION. PROVIDE A HEIGHT VERIFICATION
DEPICTING RAD CENTER AND TOP OF ANTENNA.
STATEOFARKANSAS
CERTIFICATE OF AUTHORIZATION II>-/4
RESPONSIBLE ENGINEERS:
MILD MICHAELL OWENS 1345E STRUCTURALICNIL
Tres TER&,NCEM SUPER wn ELECTRICAL
NOTICE: THIS DRAWING HAS NOT BEEN PUBLISHED AND IS THE
SOLE PROPERTY OF BBC, INC AND IS LENT TO THE BORROWER
FOR THEIR CONFIDENTIAL USE ONLY, AND IN CONSIDERATION
OF THE LOAN OF THIS DRAWING, THE BORROWER PROMISES
AND AGREES TO RETURN IT UPON REQUEST AND AGREES THAT
IT WILL NOT BE REPRODUCED, COPIED, LENT OR OTHERWISE
DISPOSED OF DIRECTLY OR INDIRECTLY, NOR USED FOR ANY
PURPOSE OTHER THAN FOR WHICH IT IS FURNISHED
4
DESIGNER: T. N TAYLOR
(3) PROPOSED
ANTENNA
1.
MOUNTING NOTESo
DESIGN AND CONSTRUCTION OF ANTENNA SUPPORTS
LEAD EE: T. SUPER
SPRINT
SHALL CONFORM TO CURRENT ANSI/EIA/TIA-222;
LEAD CEISE M. OWENS
ANTENNAS
APPENDIX B FOR WIND LOADING; "STRUCTURAL
STANDARDS FOR STEEL ANTENNA TOWERS AND
SUBMITTALS
ANTENNA SUPPORTING STRUCTURES" OR APPUCA13LE
N0. DpTE DESCRIPTION BY
CL OF PROPOSED SPRINT ANTENNAS
- -
LOCAL CODES.
A R1�06�12 FOR f�19EW 7Nf
EXISTING SPRINT ANTENNAS
2.
ALL STEEL MATERIALS SHALL BE GALVANIZED AFTER
g•-p -
FABRICATION IN ACCORDANCE WITH ASTM A123 "ZINC
(HOT -DIPPED GALVANIZED) COATINGS ON IRON AND
F_/E-LEV.5'-0
(6) EXISTING SPRINT ANTENNAS TO BE
STEEL PRODUCTS", UNLESS OTHERWISE NOTED.
c
RELOCATED AND THEN REMOVED WHEN
EQUIPMENT MIGRATION IS FINISHED
3.
ALL BOLTS, ANCHORS AND MISCELLANEOUS HARDWARE
c C4
(SEE DETAILS SHT A-4 & A-5)
SHALL BE GALVANIZED IN ACCORDANCE WITH ASTM
SITE NAME
_
A153 "ZINC (HOT -DIP) ON IRON AND STEEL
HARDWARE", UNLESS OTHERWISE NOTED.
AIRPORT - WILSON INN
4.
DAMAGED GALVANIZED SURFACES SHALL BE REPAIRS
BY COLD GALVANIZING IN ACCORDANCE WITH ASTM
11.8' 11.8"
A780.
SITE NUMBER
5.
ALL ANTENNA MOUNTS SHALL BE INSTALLED WITH
LR03XC004
DOUBLE NUTS AND SHALL BE INSTALLED SNUG TIGHT
6.
MINIMUM HORIZONTAL PACING SHALL BE 2"-0"
BETWEEN ALL ANTENNAS.
SITE ADDRESS
4301 E ROOSEVELT RD
LITTLE ROCK, ARKANSAS
PLAN VIEW FRONT VIEW
72201
SHEET TITLE
RFS APXVERR18 ANTENNA
(2) PROPOSED SPRINT
TRIPLE BAND DUAL POLARIZED
CABINETS LOCATED IN
EQUIPMENT AREA
SITE ELEVATION
FREQUENCY RANGE 806-869 & 1850-1995 MHz
ANTENNA W/O MOUNTING HARDWARE 55 lb
MOUNTING HARDWARE 7.5 lb
SHEET NUMBER
TOTAL WEIGHT 62.5 lb
800/1900 ANTENNA DETAIL 151
SITE ELEVATION
(NORTH)
131
NOTES
1
EXISTING
BUILDING
3 EXISTING SPRINT
()
ANTENNAS TO BE REMOVED
(3) EXISTING SPRINT �-
ANTENNAS TO BE REMOVED ��Y SECTOR: 1
AZIMUTH: 25'
SECTOR: 1
WHEN EQUIPMENT
v O
'
WHEN EQUIPMENT AZIMUTH: 25'
MIGRATION IS FINIS11E0
MIGRATION IS FINISHED
16
PROPOSED SPRINT
•
S p r� n t
4
OUNT
DEETAIL
(SEE 7
SHT A-9)
6580
OVERLAND PARK, KPANNSAASA65251
PROPOSED
SPRINT
H�/rsQO LEGACY
Lam_
CDMA
(OFNNA
CD►
I�
W
I
tTi1T
EXISTING SPRINT
ERICSSON
��G P EXISTING SPRINT
l
ANTENNA MOUNT
ANTENNA MOUNT
�,E•G rt,P
Go
SECTOR: 2
AZIMUTH: 100'
6100 SPRINT PARKWAY
OVERLAND PARK, KANW 66251
SECTOR: 2
SECTOR: 3
SECTOR: 3 AZIMUTH: 100'
AZIMUTH: 240
PROPOSED
AZIMUTH: 240'
SPRINT FILTERS
F3)
(TYPOF 3)
� �
EXISTING
EXISTING
STAIRS
pppp,,
I3'
STAIRS
PROPOSED
S S C
SPRINT A2 MODULES
(TYPICAL OF 3)
9900 West 109th Street, Suite 300
Ovedand Pads, Kansas 66210
Phone: 91=8-7700 Fat:913438-7777
EXISTING COAX
TO BE REMOVED
WHEN EQUIPMENT
PROPOSED
MIGRATION IS
SPRINT RRU'S
FINISHED (TYP)
(TYPICAL OF 9)
EXISTING COAX
TO BE REMOVED
WHEN EQUIPMENT
MIGRATION IS
FINISHED (TYP)
PROPOSED (3)
STATE OF ARKANSAS
SPRINT HYBRID
CERTIFICATE OF AUTHORIZATION N 74
EXISTING
CABLES
RESPONSIBLE ENGINEERS:
EXISTING
BUILDING
MUD MICHAELL OWENS 13450 STRUCTURAUCML
BUILDING
TMS TERRANCEM SUPER 9717 ELECTRICAL
EXISTING ANTENNA LAYOUT 3
TEMPORARY ANTENNA LAYOUT
NOTICE THIS DRAWING HAS NOT BEEN PUBLISHED AND IS THE
SOLE PROPERTY OF SSC, INC AND IS LENT TO THE BORROWER
EXISTING CABLE TRAY
SECTOR: 1 _
AZIMUTH' 25
FORTH LOAN IR IDERATION
THIS DRAWINGL USE .
THEB BORROWER PROMISES
OF THE LOAN OF THIS DRAWING, THE BORROWER PROMISES
AND AGREES TO RETURN IT UPON REQUEST AND AGREES THAT
NOTE:
NEW CABLES ROUTED UP 1. EXACT ROUTING OF CABLES TO BE
DETERMINED BY STRUCTURAL ANALYSIS
PROPOSED SPRINT
IT WILL NOT BE REPRODUCED, COPIED, LENT OR OTHERWISE
DISPOSEDOF DIRECTLY OR INDIRECTLY, NOR USED FOR ANY
PURPOSEOTHER THAN FOR WHICH IT IS FURNISHED
EXISTING CABLE TRAY
(BY OTHERS)
Q, ANTENNA MOUNT
DESIGNER: T.N.TAYLOR
ti (SEE DETAIL 7
2. NEW GPS ANTENNA TO BE AT LEAST
�� SHT A-9)
LEAD EE: T. SUPER
— EXISTING ICE BRIDGE 4' FROM EXISTING GPS ANTENNAS
PROPOSED
SPRINT ANTENNA
1900
LEAD CESE: M. OWENS
(TYPICAL OF 3)
A1i{x
SUBMITTALS
NO DATE DESCRIPTION IT
A 11�06�f2 ISSUED FOR KM TH
NEW CABINETS ON
EXISTING EQUIPMENT
I �g�
$�
PLATFORM
SECTOR: 2
AZIMUTH: 100'
SECTOR: 3
AZIMUTH: 240'
PROPOSED
SITE NAME
'114
SPRINT FILTERSEXISTING (TYPICAL OF 3)
AIRPORT - WMSON INN
STAIRS
PROPOSED
EXISTING EQUIPMENT
SPRINT A2 MODULES
SITE NUMBER
CONCRETE PAD
(TYPICAL OF 3)
LR03XCO04
4 d
rf�r r r rrr rrrr rr
PROPOSED
SITE ADDRESS
f
'<\\�f\�� r�\/
S(TYPICCAL ONT F 9)
4301 E ROOSEVELT RD
\, \�\\�f\��\\\�;\r/\\
LITTLE ROCK, ARKANSAS
(3) NEW HYBRID TOWER CABLES
72201
FROM REAR OF CABINET ROUTED
ON EXISTING CABLE BRIDGE
SHEETTITLE
(1) SHOWN FOR CLARITY
CABLES ATTACHED TO EXISTING
ANTENNA PLANS
SUPPORTS WITH ROSENBERGER
PROPOSED
GROMMET HANGER KIT
SPRINT HYBRID
PART# CS624—TH415
EXISTING CABLES
SHEET NUMBER
BUILDING
A
COAX RUN DIAGRAM 4
FINAL ANTENNA LAYOUT
2
` 1-`t