HomeMy WebLinkAboutZ-8842 Staff AnalysisITEM NO.: 3,
NAME: CARTI Zoning Site Plan Review
LOCATION: located on Riley Drive at John Barrow Road
Planning Staff Comments.-
Z-8842
1 . Provide notification of the property owners located within 200-feet of the site
including the certified abstract list, notice form with affidavit executed and proof of
mailing. The notice must be mailed no later than February 20, 2013. The Office of
Planning and Development must receive the proof of notice no later than March 1,
2013.
2. Provide the maximum height of the proposed parking deck/garage. The area to the
south is single-family homes. Provide details of how the impact of the garage will be
mitigated on these homes.
3. Will there be overnight stay associated with the proposed use of the building? If no
provide the number of rooms proposed for overnight stay.
4. Provide details of the school and residency program. Provide the total number of
students to be served.
Variance/VVaivers: None requested.
Public Works Conditions:
1. Barrow Road is classified on the Master Street Plan as a minor arterial. A dedication
of right-of-way 45 feet from centerline will be required.
2. A 20 foot radial dedication of right-of-way is required at the intersection of Barrow
Road and Riley Drive.
3. Sidewalks with appropriate handicap ramps are required to be installed along Riley
Drive in accordance with Section 31-175 of the Little Rock Code and the Master
Street Plan.
4. All driveways shall be concrete aprons per City Ordinance.
5. Driveway locations and widths do not meet the traffic access and circulation
requirements of Sections 30-43 and 31-210. The width of driveway must not exceed
36 feet. The minimum width of a driveway lane is 20 feet for fire access. A variance
should be requested for the location of the east driveway.
6. Repair or replace any curb and gutter or sidewalk that is damaged in the public right-
of-way prior to occupancy.
7. Plans of all work in right-of-way shall be submitted for approval prior to start of work.
Obtain barricade permit prior to doing any work in the right-of-way from Traffic
Engineering at (501) 379-1805 (Travis Herbner).
8. A grading permit in accordance with Section 29-186 (c) and (d) will be required prior
to any land clearing or grading activities at the site. Other than residential
subdivisions, site grading and drainage plans must be submitted and approved prior
to the start of construction. If grading is desired beyond the area to be developed, a
variance to advance grade must be requested.
Item # 3.
9. Provide a Sketch Grading and Drainage Plan per Section 29-186 (e).
10. Stormwater detention ordinance applies to this property. Show the proposed
location for stormwater detention facilities on the plan.
11.If disturbed area is one (1) or more acres, obtain a NPDES stormwater permit from
the Arkansas Department of Environmental Quality prior to the start of construction.
12.Streetlights are required by Section 31-403 of the Little Rock code. Provide plans
for approval to Traffic Engineering. Streetlights must be installed prior to
platting/certificate of occupancy. Contact Traffic Engineering 379-1813 (Greg
Simmons) for more information.
13. Provide a letter prepared by a registered engineer certifying the sight distance at the
intersections comply with 2004 AASHTO Green Book standards.
14. Damage to public and private property due to hauling operations or operation of
construction related equipment from a nearby construction site shall be repaired by
the responsible party prior to issuance of a certificate of occupancy.
15. Retaining walls designed to exceed 15 feet in height are required to seek a variance
for construction. Provide proposed wall elevations.
16. Prior to construction of retaining walls, an engineer's certification of design and plans
must be submitted to Public Works for approval. After construction, an as -built
certification is required for construction of the retaining wall.
Utilities and Fire Department/County Planning:
Wastewater: Sewer main extension required with easements for this project. Contact
Little Rock Wastewater Utility for additional information.
Enter : No comment received.
Center -Point Energy: No comment received
AT & T: No comment received.
Central Arkansas Water: All Central Arkansas water requirements in effect at the
time of request for water service must be met. A water main extension will be needed
to provide water service to this property. This development will have minor impact on
the existing water distribution system. Proposed water facilities will be sized to provide
ade3quate pressure and fire protection. The Little Rock Fire Department needs to
evaluate this site to determine whether additional public and/or private fire hydrant(s)
will be required. If additional fire hydrant(s) are required, they will be installed at the
Developer's expense. Please submit plans for water facilities and/or fire protection
system to central Arkansas Water for review. Plan revisions may be required after
additional review. Contact Central Arkansas regarding procedures for installation of
water facilities and/or fire service. Approval of plans by the Arkansas Department of
Health Engineering Division and Little Rock Fire Department is required. Contact
Central Arkansas Water regarding the size and location of the water meter. A Capital
Investment Charge based on the size of meter connection(s) will apply to this project in
addition to normal charges. This fee will apply to all connections including meter
connections off the private fire system. If there are facilities that need to be adjusted
and/or relocated, contact Central Arkansas Water. That work would be done at the
expense of the developer. Due to the nature of this facility, installation of an approved
Item 4 3.
reduced pressure zone backflow preventer assembly (RPZA) is required on the
domestic water service. This assembly must be installed prior to the first point of use.
Central Arkansas Water requires that upon installation of the RPZA, successful tests of
the assembly must be completed by a Certified Assembly Tester licensed by the State
of Arkansas and approved by Central Arkansas Water. The test results must be sent to
Central Arkansas Water's Cross Connection Section within ten days of installation and
annually thereafter. Contact the Cross Connection Section at 377-1226 if you would
like to discuss backflow prevention requirements for this project. The facilities on -site
will be private. When meters are planned off private lines, private facilities shall be
installed to Central Arkansas Water's material and construction specifications and
installation will be inspected by an engineer, licensed to practice in the State of
Arkansas. Execution of a Customer Owned Line Agreement is requires.
Fire Department: Maintain access of at least twenty (20) feet; fire hydrants per Code.
Contact Fire Marshall Tony Rhodes at 607-3560 with any questions.
County Planning: No comment.
CATA: The site is not located on a dedicated CATA Bus Route.
Parks and Recreation: No comment received.
Planning Division: No comment.
Landscape:
1. Site plan must comply with the City's landscape and buffer ordinance requirements.
2. All interior islands are to be three hundred (300) square feet in area; some -spaces
are designed at one hundred fifty (150) square feet.
3. Areas set aside appear to meet the minimal landscape and buffer ordinance
requirements.
4. An automatic irrigation system to water landscaped areas will be required.
5. Prior to the issuance of a building permit, it will be necessary to provide an approved
landscape plan stamped with the seal of a Registered Landscape Architect.
6. The City Beautiful Commission recommends preserving as many existing trees as
feasible on this site. Credit toward fulfilling Landscape Ordinance requirements can
be given when preserving trees of six (6) inch caliper or larger
Revised plat/plam Submit four (4) copies of a revised preliminary plat/plan (to include
the additional information as noted above) to staff on Wednesday, February 20, 2013.
Item # 3.
March 7, 2013
ITEM NO.: 3
NAME: CARTI Zoning Site Plan Review
LOCATION: Located on Riley Drive at John Barrow Road
DEVELOPER:
CARTI
9500 Kanis Road
Little Rock, AR 72205
FNC,INFFR-
Crafton Tull
10825 Financial Center Parkway
Little Rock, AR 72211-3554
AREA: 19.49 acres
CURRENT ZONING
PLANNING DISTRICT
CENSUS TRACT:
NUMBER OF LOTS: 1
FILE NO
FT. NEW STREET: 0 LF
0-2, Office and Institutional District
10 — Boyle Park
24.03
VARIANCES/WAIVERS REQUESTED:
1. A variance from Sections 30-43 and 31-210 to allow the eastern driveway nearer the
property line than typically allowed.
2. A deferral of the placement of the sidewalk along Riley Drive outside the area
proposed for development until development of the property abutting the sidewalk is
developed or until the property along the north side of Riley Drive occurs.
A. PROPOSAL/REQUEST/APPLICANT'S STATEMENT:
The request is a site plan review application for a 19.49 acre tract generally
located at Riley Drive and John Barrow Road. The site is currently zoned 0-2,
Office and Institutional District and is undeveloped. The proposed use is a
165,000 square foot medical facility. The building will be four floors plus a partial
basement. The highest occupied floor will be 48-feet above the ground floor
elevation and the top of the parapet will be 78-feet above the first floor elevation.
The building will consist of stone, brick curtain wall with exposed steel and
March 7, 2013
SUBDIVISION
ITEM NO.: 3 Cont. FILE NO.: Z-8842
standing seam canopies on the first floor. The second through fourth floors will
be brick, metal panels, and curtain wall with exposed steel sunscreens. The
penthouse will be louvers, metal panel and/or brick.1.
The facility will take access from Riley Drive and provide a total of 694 parking
spaces for administration, medical staff, patients and visitors/public. The plan
includes the placement of 440 parking spaces within the proposed parking deck
and 254 surface parking spaces.
The request includes a variance from Sections 30-43 and 31-210 to allow the
eastern drive nearer the property line than typically allowed. The request also
includes a deferral of a portion of the required sidewalk along Riley Drive until the
development of the western portion of the site or until the development of the
property located along the north side of Riley Drive.
B. EXISTING CONDITIONS:
The property is heavily wooded sloping from Riley Drive to the south. The
property to the north is also heavily wooded and is also owned by the applicant.
To the east are an assisted living facility and a nursing home. Uses to the south
include a church accessed from Kanis Road, single-family homes located on
Michael Drive and office uses located on Business Park Drive. Fronting John
Barrow Road at Riley Drive is a large office user, Arvest Banking Center, and
there is a Stroman's rental business located on the northeast corner of John
Barrow Road and Riley Drive.
C. NEIGHBORHOOD COMMENTS:
As of this writing, staff has not received any comment from area residents. All
property owners located within 200 feet of the site, the John Barrow
Neighborhood Association and the Brownwood Terrace Neighborhood
Association were notified of the public hearing.
D. ENGINEERING COMMENTS:
PUBLIC WORKS CONDITIONS:
1. John Barrow Road is classified on the Master Street Plan as a minor
arterial. A dedication of right-of-way 45 feet from centerline will be required.
2. A 20 foot radial dedication of right-of-way is required at the intersection of
John Barrow Road and Riley Drive.
2
March 7, 2013
SUBDIVISION
ITEM NO.: 3 Cont. FILE NO.: Z-8842
3. Sidewalks with appropriate handicap ramps are required to be installed
along Riley Drive in accordance with Section 31-175 of the Little Rock Code
and the Master Street Plan.
4. All driveways shall be concrete aprons per City Ordinance.
5. Driveway locations and widths do not meet the traffic access and circulation
requirements of Sections 30-43 and 31-210. The width of driveway must
not exceed 36 feet. The minimum width of a driveway lane is 20 feet for fire
access. A variance should be requested for the location of the east
driveway.
6. Repair or replace any curb and gutter or sidewalk that is damaged in the
public right-of-way prior to occupancy.
7. Plans of all work in right-of-way shall be submitted for approval prior to start
of work. Obtain barricade permit prior to doing any work in the right-of-way
from Traffic Engineering at (501) 379-1805 (Travis Herbner).
8. A grading permit in accordance with Section 29-186 (c) and (d) will be
required prior to any land clearing or grading activities at the site. Other
than residential subdivisions, site grading and drainage plans must be
submitted and approved prior to the start of construction. If grading is
desired beyond the area to be developed, a variance to advance grade
must be requested.
9. Provide a Sketch Grading and Drainage Plan per Section 29-186 (e).
10. Stormwater detention ordinance applies to this property. Show the
proposed location for stormwater detention facilities on the plan.
11. If disturbed area is one (1) or more acres, obtain a NPDES stormwater
permit from the Arkansas Department of Environmental Quality prior to the
start of construction.
12. Streetlights are required by Section 31-403 of the Little Rock code. Provide
plans for approval to Traffic Engineering. Streetlights must be installed prior
to platting/certificate of occupancy. Contact Traffic Engineering 379-1813
(Greg Simmons) for more information.
13. Provide a letter prepared by a registered engineer certifying the sight
distance at the intersections comply with 2004 AASHTO Green Book
standards.
14. Damage to public and private property due to hauling operations or
operation of construction related equipment from a nearby construction site
shall be repaired by the responsible party prior to issuance of a certificate of
occupancy.
15. Retaining walls designed to exceed 15 feet in height are required to seek a
variance for construction. Provide proposed wall elevations.
3
March 7, 2013
SUBDIVISION
ITEM NO.: 3 (Cont.) FILE NO.: Z-8842
16. Prior to construction of retaining walls, an engineer's certification of design
and plans must be submitted to Public Works for approval. After
construction, an as -built certification is required for construction of the
retaining wail.
E. UTILITIES AND FIRE DEPARTMENT/COUNTY PLANNING:
Wastewater: Sewer main extension required with easements for this project.
Contact Little Rock Wastewater Utility for additional information.
Entergy: No comment received.
Center -Point Ener : No comment received.
AT & T: No comment received.
Central Arkansas Water: All Central Arkansas Water requirements in effect at
the time of request for water service must be met. A water main extension will be
needed to provide water service to this property. This development will have
minor impact on the existing water distribution system. Proposed water facilities
will be sized to provide adequate pressure and fire protection. The Little Rock
Fire Department needs to evaluate this site to determine whether additional
public and/or private fire hydrant(s) will be required. If additional fire hydrant(s)
are required, they will be installed at the Developer's expense. Please submit
plans for water facilities and/or fire protection system to Central Arkansas Water
for review. Plan revisions may be required after additional review. Contact
Central Arkansas Water regarding procedures for installation of water facilities
and/or fire service. Approval of plans by the Arkansas Department of Health
Engineering Division and Little Rock Fire Department is required. Contact
Central Arkansas Water regarding the size and location of the water meter. A
Capital Investment Charge based on the size of meter connection(s) will apply to
this project in addition to normal charges. This fee will apply to all connections
including meter connections off the private fire system. If there are facilities that
need to be adjusted and/or relocated, contact Central Arkansas Water. That
work would be done at the expense of the developer. Due to the nature of this
facility, installation of an approved reduced pressure zone backflow preventer
assembly (RPZA) is required on the domestic water service. This assembly must
be installed prior to the first point of use. Central Arkansas Water requires that
upon installation of the RPZA, successful tests of the assembly must be
completed by a Certified Assembly Tester licensed by the State of Arkansas and
approved by Central Arkansas Water. The test results must be sent to Central
4
March 7, 2013
SUBDIVISION
ITEM NO.: 3 (Cont.
LE NO.: Z-8842
Arkansas Water's Cross Connection Section within ten days of installation and
annually thereafter. Contact the Cross Connection Section at 377-1226 if you
would like to discuss backflow prevention requirements for this project. The
facilities on -site will be private. When meters are planned off private lines,
private facilities shall be installed to Central Arkansas Water's material and
construction specifications and installation will be inspected by an engineer,
licensed to practice in the State of Arkansas. Execution of a Customer Owned
Line Agreement is requires.
Fire Department: Maintain access of at least twenty (20) feet; place fire
hydrants per Code. Contact Fire Marshall Tony Rhodes at 607-3560 with any
questions.
County Planning: No comment.
CATA: The site is not located on a dedicated CATA Bus Route.
Parks and Recreation: No comment received.
F. ISSUESRTECHNICAUDESIGN:
Planning Division: No comment,
Landscape:
1. Site plan must comply with the City's landscape and buffer ordinance
requirements.
2. All interior islands are to be three hundred (300) square feet in area.
3. Areas set aside appear to meet the minimal landscape and buffer ordinance
requirements.
4. An automatic irrigation system to water landscaped areas will be required.
5. Prior to the issuance of a building permit, it will be necessary to provide an
approved landscape plan stamped with the seal of a Registered Landscape
Architect.
6. The property abuts single-family residential homes to the south therefore a
land use buffer of 30-feet is required.
7. The City Beautiful Commission recommends preserving as many existing
trees as feasible on this site. Credit toward fulfilling Landscape Ordinance
requirements can be given when preserving trees of six (6) inch caliper or
larger.
5
March 7, 2013
SUBDIVISION
ITEM NO.: 3(Cont)FILE NO.: Z-8842
G. SUBDIVISION COMMITTEE COMMENT: (February 13, 2013)
Mr. Frank Riggins was present representing the request. Staff presented an
overview stating the request was for a zoning site plan review of this 0-2, Office
and Institutional zoned site. Staff questioned the height of the parking
deck/garage. Staff also questioned if there would be overnight stay associated
with the medical facility. Staff questioned if there would be a school and/or
residency program and the number of students to be served.
Public Works comments were addressed. Staff stated dedication of right of way
on John Barrow Road would be required. Staff also stated all driveways were to
be concrete aprons per City code. Staff stated the driveway locations and widths
did not meet the access and circulation requirements of Sections 30-43 and
31-210. Staff stated a variance should be requested to allow the eastern
driveway in the proposed location. Staff stated a variance would be needed for
any retaining walls designed to exceed 15-feet in height. Staff requested the
applicant provide the proposed wall elevations.
Staff noted comments from the other reporting departments and agencies
suggesting the applicant contact them individually for additional clarification.
There was no further discussion of the item. The Committee then forwarded the
item to the full Commission for final action.
H. ANALYSIS:
The applicant submitted a revised site plan addressing staffs concerns raised at
the February 13, 2013, Subdivision Committee meeting. The applicant has
indicated there will be no overnight stay associated with the medical office facility
and there is not be a residency program. The applicant has also provided the
total height of the proposed parking deck which will not exceed 37-feet above the
finished floor elevation of the structure. The applicant has indicated all retaining
walls will comply with the City's Land Alteration Ordinance.
The property is zoned 0-2, Office and Institutional which requires site plan review
prior to development. All development is reviewed on a case by case basis to
consider the particulars of the project including the provision of parking and
landscaping in accordance with appropriate ordinances, siting of buildings and
the compatibility of the proposed development with adjacent uses. All
developments are to be designed in such a way as to minimize any potential
harmful impact on the surrounding area.
The building is proposed to contain 165,000 square feet and will be used as a
medical facility. The building will be four floors plus a partial basement. The
highest occupied floor will be 48-feet above the ground floor elevation and the
0
March 7, 2013
SUBDIVISION
ITEM NO.: 3 Cont. FIDE NO.: Z-8842
top of the parapet will be 78-feet above the first floor elevation. The zoning
ordinance allows a maximum building height of 45-feet with an additional foot of
height added to the building for each foot the building is setback from the
required setback line for a maximum height of 120-feet. The required front, side
and rear yard setback for the 0-2, Office and Institutional Zoning District is
25-feet. The plan as presented more than exceeds the setback requirement.
The 0-2, Office and Institutional Zoning District states all buildings shown on the
site plan shall cover an aggregated area of not more than forty (40) percent of
the area of the site. The building, including expansion areas, has a footprint of
175-feet by 350-feet. The parking deck has a building footprint of 440-feet by
285-feet. The site contains 19.49 acres. The building coverage is well below
that allowed by the Zoning District.
The Zoning and Buffer Ordinance requires a 30-foot land use buffer along the
southern perimeter where adjacent to residentially used property. The site plan
has increased the required buffer adjacent to the parking deck from 30-feet to
50-feet. The applicant has noted evergreen trees will be planted 15-feet on
center between the parking deck and the single-family homes to protect the
integrity of the single-family residences.
The building will consist of stone, brick curtain wall with exposed steel and
standing seam canopies on the first floor. The second through fourth floors will
be brick, metal panels, and curtain wall with exposed steel sunscreens. The
penthouse will be louvers, metal panel and/or brick.
The facility will take access from Riley Drive and provide a total of 694 parking
spaces for administration, medical staff, patients and visitors/public. There are
254 surface parking spaces proposed and 440 spaces within the parking deck.
The zoning ordinance would require the placement of 412 parking spaces to
serve an office use. The applicant has indicated the facility is heavily staffed
creating a parking demand greater than the zoning ordinance typically requires.
The request includes a variance from Sections 30-43 and 31-210 to allow the
eastern most drive to be located nearer the property line than typically allowed.
The ordinance states driveways are to be located a minimum of 125-feet from the
property line. The centerline of the eastern drive is located approximately 30-feet
from the property line.
The request includes a deferral of a portion of the sidewalk along Riley Drive.
The applicant has indicated the sidewalk will be constructed adjacent to the
proposed development area of the site and is requesting a deferral of the
required sidewalk in the area proposed for detention until this portion of the site is
developed or until the area north of Riley Drive is developed.
7
March 7, 2013
SUBDIVISION
ITEM NO.: 3 Cont. FILE NO.: Z-8842
Staff is supportive of the request. To staffs knowledge there are no outstanding
technical issues associated with the request. Although there are variances
associated with the request, staff does not feel the variances and the proposed
development of a medical office will significantly impact the area.
STAFF RECOMMENDATION:
Staff recommends approval of the request subject to compliance with the
comments and conditions as outlined in paragraphs D, E and F of the agenda
staff report.
Staff recommends approval of the variance request from Sections 30-43 and
31-210 to allow the eastern drive to remain as indicated on the site plan.
Staff recommends approval of the deferral request of the placement of the
sidewalk within the western portion of the development in the area proposed for
detention until this portion of the site is developed or until the area north of Riley
Drive is developed.
PLANNING COMMISSION ACTION:
(MARCH 7, 2013)
The applicant was present. There were no registered objectors present. Staff
presented the item with a recommendation of approval of the request subject to
compliance with the comments and conditions as outlined in paragraphs D, E and F of
the agenda staff report. Staff presented a recommendation of approval of the variance
request from Sections 30-43 and 31-210 to allow the eastern drive to remain as
indicated on the site plan. Staff presented a recommendation of approval of the deferral
request of the placement of the sidewalk within the western portion of the development
in the area proposed for detention until that portion of the site was developed or until the
area north of Riley Drive was developed.
There was no further discussion of the item. The Chair entertained a motion for
approval of the item as presented by staff. The motion carried by a vote of 10 ayes,
0 noes, 0 absent and 1 open position.