Loading...
HomeMy WebLinkAboutZ-8646-A Map 1MATCH EXISTINGI CURB AND GUTTER /I LLI LLJ OCA O co I R6 Z , Z LLI A 1=1 . �I I. SIGN LOT 1A 21950 S.F. v try io M 39.7' ALK S SETBACK 5_SETBACK 10 oz- - - r ----- ------ --�� CONC. WALK ----` ----- " WATERLINE 'I EXISTING "SIGN E) CONC. SH ------ -- _ -- --- -- _______________1------ - - —/---� MATCH EXISTINGf" EXISTING CURB - CURB AND GUTTER AND GUTTER PROPOSED- -- CONIC. DRIVEWAY MATCH EXISTING - ASPHALT -i----OHE— I —OHE— 1 —OHE— t� SITE NOTES 1. ALL WORK AND MATERIALS SHALL COMPLY WITH ALL CITY/COUNTY/STATE/FEDERAL REGULATIONS AND CODES AND OSHA STANDARDS. 2. CONTRACTOR SHALL REFER TO ARCHITECTURAL PLANS FOR EXACT LOCATIONS AND DIMENSIONS OF VESTIBULES, SLOPE PAVING, SIDEWALKS, EXIT PORCHES, TRUCK DOCKS, PRECISE BUILDING DIMENSIONS AND EXACT UTILITY ENTRANCE LOCATIONS. 3. ALL DIMENSIONS AND RADII ARE TO BACK OF CURB UNLESS OTHERWISE NOTED. 4. ALL WORK SHALL BE DONE IN STRICT ACCORDANCE WITH THE PROJECT SPECIFICATIONS. 5. ALL CURB/SIDEWALK/HANDICAP RAMP DESIGNS SHALL CONFORM TO ADA STANDARDS OR LOCAL RESTRICTIVE CODES, WHICHEVER IS MORE RESTRICTIVE. 6. CONTRACTOR SHALL ENSURE ALL NECESSARY PERMITS ARE OBTAINED PRIOR TO CONSTRUCTION START. 7. CONTRACTOR SHALL MATCH PROPOSED CURB AND GUTTER, CONCRETE, AND PAVEMENT TO EXISTING IN GRADE AND ALIGNMENT. 8. CONTRACTOR SHALL MAINTAIN ALL EXISTING PARKING, SIDEWALKS, DRIVES, ETC. CLEAR AND FREE FROM ANY CONSTRUCTION ACTIVITY AND/OR MATERIAL TO ENSURE EASY AND SAFE PEDESTRIAN AND VEHICULAR TRAFFIC TO AND FROM THE SITE. 5' LOT 2A 2,950 S.F. IN OAK 5' 1C LOT 12 MATCH E ISTING CURB AND UTTER EXISTING 18" WILLOW OAK TO. BE REMOVED I 90.0' I ! _�� EXISTING TREES TO BE MATCH EXISTING REMAIN AND PRESERVED CURB AND GUTTER DURING CONSTRUCTION WEST 13TH STREET (ASPHALT/CONC. — 60' ROW) ---•-OHE--�--OHE---T—OHI�— a. _. __.. — EXISTING BUILDING — LEGEND (EXISTING) GRAPHIC SCALE IN FEET SYMBOLS LINEWORK 20' 0 20' 0 FOUND IRON PIN EASEMENT LIGHT POLE --------------------------------------------------------- 1R POWER POLE CURB m TELEPHONE PEDESTAL TV PEDESTAL INTERMEDIATE CONTOUR i O .......... MANHOLE INDEX CONTOUR a SANITARY SEWER CLEANOUT ----s =—_--s-----s_ 0 GAS METER SANITARY SEWER LINE Da GAS VALVE----�__----— GAS LINE STORM SEWER PIPE ----w-----•------ �! DOWN GUY WATER LINE (SPECIFY SIZE & TYPE) f Da WATER VALVE-----IICT------UCT FIRE HYDRANT ASSEMBLY UNDERGROUND TELEPHONE ce—um— CONC. PROPOSED � AIR RELEASE VALVE —ucE—i DRIVEWAY UNDERGROUND ELECTRIC FIRE DEPARTMENT CONNECTION MATCH EXISTING —0 �— E OT ASPHALT 0 WATER METER OVERHEAD ELECTRIC H— ® SPRINKLER HEAD ----- ry-----ury— LLJ to ELECTRIC PEDESTAL UNDERGROUND TELEVISION Cryry— I' N OVERHEAD TELEVISION GRATED INLET Y- .......... ... Q I CHAIN LINK FENCE if 11 a —I II DROP INLET WOOD FENCE 0 N BARBED WIRE FENCE N I Q TREE FIBER OPTIC RIGHT OF WAY MATCH EXISTING �\ '' TREE TO BE REMOVED CURB ND GUTIER ROAD CENTERLINE PROPO COCK. IDEWALK ENGINEER'S NOTICE TO CONTRACTOR THE EXISTENCE AND LOCATION OF ANY UNDERGROUND UTILITY PIPES OR STRUCTURES SHOWN ON 114ESE DRAWINGS ARE OBTAINED BY A SEARCH OF THE AVAILABLE RECORDS. TO THE BEST OF OUR KNOWLEDGE THERE ARE NO EXISTING UTILITIES EXCEPT AS SHOWN ON THESE DRAWINGS AND WE ASSUME NO RESPONSIBILITY AS TO THE ACOURACY OF THEIR DEPICTED LOCATION ON THESE DRAWINGS. THE CONTRACTOR IS REQUIRED TO TAKE DUE PRECAUTIONARY MEASURES TO PROTECT THE UTILITY LINES SHOWN, AND ALL OTHER LINES NOT OF RECORD OR NOT SHOWN ON THESE DRAWINGS BY VERIFICATION OF THEIR LOCATION IN THE FIELD PRIOR TO THE INITIATION OF THE ACTUAL PORTION OF THEIR WORK. SAFETY NOTICE TO CONTRACTOR IN ACCORDANCE WITH GENERALLY ACCEPTED CONSTRUCTION PRACTICES, THE CONTRACTOR WILL BE SOLELY AND COMPLETELY RESPONSIBLE FOR CONDITIONS OF THE JOB SITE, INCLUDING SAFETY OF ALL PERSONS AND PROPERTY DURING PERFORMANCE OF THE WORK. THIS REQUIREMENT WILL APPLY CONTINUOUSLY AND NOT BE LIMITED TO NORMAL WORKING HOURS. THE DUTY OF THE ENGINEER TO CONDUCT CONSTRUCTION REVIEW OF THE CONTRACTORS PERFORMANCE IS NOT INTENDED TO INCLUDE REVIEW OF THE ADEQUACY OF THE CONTRACTOR'S SAFETY MEASURES, IN, OR NEAR THE CONSTRUCTION SITE. OWNERSHIP OF DOCUMENTS THIS DOCUMENT, AND THE IDEAS AND DESIGNS INCORPORATED HEREIN, AS AN INSTRUMENT OF PROFESSIONAL SERVICES, IS THE PROPERTY OF CRAFTON, TULL & ASSOCIATES, INC., AND IS NOT TO BE USED, IN WHOLE OR PART, FOR ANY OTHER PROJECT WITH OUT THE WRITTEN AUTHORIZATION OF CRAFTON, TULL & ASSOCIATES, INC. NOTIFICATION OF LIMITED SERVICES CRAFTON, TULL & ASSOCIATES, INC., (CTA) HAS NOT BEEN RETAINED BY THE OWNER FOR CONSTRUCTION ADMINISTRATION OR OBSERVATION SERVICES ON ALL OR A PORTION OF THE WORK INDICATED ON THESE DRAWINGS. THEREFORE, THE CTA HEREBY NOTIFIES ALL PARTIES INVOLVED THAT THE CTA ASSUMES NO RESPONSIBILITY FOR THE INTERPRETATION, COORDINATION AND ADMINISTRATION Of THESE DOCUMENTS AND/OR DEVIATIONS THEREFROM AND THE EFFECTS THOSE CHANGES MAY HAVE ON ANY AND ALL RELATED TRADES OR CONSTRUCTION SEQUENCES, OR OPERATION OF THE COMPLETED PROJECT, EXCEPT AS SPEC— IFICALLY REQUIRED IN THE CTA's SERVICES AGREEMENT WITH THE OWNER. (le LEGEND (PROPOSED) SYMBOLS LINEWORK • SET IRON PIN --------'------------------- EASEMENT LIGHT POLE 1R POWER POLE CURB ■ TELEPHONE PEDESTAL 1206 Is TV PEDESTAL INTERMEDIATE CONTOUR Q MANHOLE 1205 INDEX CONTOUR 0 SANITARY SEWER CLEANOUT GAS METER SANITARY SEWER LINE N GAS VALVE , O STORM SEWER PIPE GAS LINE z-z STRUCTURE NUMBER IF WATER LINE ►t WATER VALVE ►� FIRE HYDRANT ASSEMBLY UNDERGROUND TELEPHONE NN AIR RELEASE VALVE .=r FIRE DEPARTMENT CONNECTION UNDERGROUND ELECTRIC • WATER METER OVERHEAD ELECTRIC 6 BACK FLOW PREVENTER A REDUCER FIBER OPTIC • PLUG VALVE — uon ❑ GRATED INLET UNDERGROUND TELEVISION 0mv ,,,,, OVERHEAD TELEVISION DROP INLET CHAIN LINK FENCE v gIG! ARC D �N IL O w Z m ITT WOOD FENCE X -R X BARBED WIRE FENCE BUILDING SET BACK RIGHT OF WAY PROPERTY LINE ROAD CENTERLINE JUN 0 8 2015 10825 Financial Center Parkway, Suite 300 Little Rock, Arkansas 12211 Crafton Tull ® engineering i surveying 501.664.3245 t 501 .664.6704 f www.craftontull.com CERTIFICATE OF AUTHORIZATION , " ,,,,O,F, .AU, CRAFTON, TULL & ASSOCIATES, INC. DZ No. 109 >y o= gPrAN5A5 EIK+1�E¢� VANN ADDITION (A REPLAT OF THE SOUTH 501 OF LOTS 7,819110,11 & 12 OF BLOCK 3, PARKADDITION TO THE CITY OF LITTLE ROCK, PULASKI COUNTY, ARKANSAS) 2284 WEST 13th STREET LITTLE ROCK, AR Key Plan No. Descup6on Date This document, and the ideas and designs incorporated herein, as an instrument of professional service, is the property of Crafton, Tull & Associates, Inc., and is not to be used, in whole or in part, for any other project, without the written authorization of Crafton, Tull & Associates, Inc. N`'�POCTION PROJECTNO: 118022-00 G° ISSUEDATE: 04/06/11 �O� THIS F� CONTACT: B.PETERSON DOCUMENT IS N CHECKED BY: ° PRELIMINARY IN NATURE AND IS NOT PRELIMINARY w A FINAL, SIGNED o PLANS N AND SEALED DOCUMENT a° c zoi i o-aJton, Tull & al Assoate:, Inc. 6 O° °° NOIlOOd LSN LAYOUT PLAN