HomeMy WebLinkAboutZ-8646-A Map 1MATCH EXISTINGI
CURB AND GUTTER /I
LLI
LLJ
OCA
O co I R6
Z ,
Z
LLI
A
1=1 .
�I I.
SIGN
LOT 1A
21950 S.F.
v try io
M 39.7'
ALK S SETBACK 5_SETBACK
10
oz- - - r ----- ------ --��
CONC. WALK ----` ----- "
WATERLINE 'I
EXISTING "SIGN
E)
CONC. SH
------ -- _ -- --- -- _______________1------ - - —/---�
MATCH EXISTINGf"
EXISTING CURB - CURB AND GUTTER
AND GUTTER PROPOSED-
-- CONIC. DRIVEWAY
MATCH EXISTING -
ASPHALT
-i----OHE— I —OHE— 1 —OHE—
t� SITE NOTES
1. ALL WORK AND MATERIALS SHALL COMPLY WITH ALL
CITY/COUNTY/STATE/FEDERAL REGULATIONS AND CODES AND OSHA
STANDARDS.
2. CONTRACTOR SHALL REFER TO ARCHITECTURAL PLANS FOR EXACT
LOCATIONS AND DIMENSIONS OF VESTIBULES, SLOPE PAVING,
SIDEWALKS, EXIT PORCHES, TRUCK DOCKS, PRECISE BUILDING
DIMENSIONS AND EXACT UTILITY ENTRANCE LOCATIONS.
3. ALL DIMENSIONS AND RADII ARE TO BACK OF CURB UNLESS OTHERWISE
NOTED.
4. ALL WORK SHALL BE DONE IN STRICT ACCORDANCE WITH THE PROJECT
SPECIFICATIONS.
5. ALL CURB/SIDEWALK/HANDICAP RAMP DESIGNS SHALL CONFORM TO
ADA STANDARDS OR LOCAL RESTRICTIVE CODES, WHICHEVER IS MORE
RESTRICTIVE.
6. CONTRACTOR SHALL ENSURE ALL NECESSARY PERMITS ARE OBTAINED
PRIOR TO CONSTRUCTION START.
7. CONTRACTOR SHALL MATCH PROPOSED CURB AND GUTTER, CONCRETE,
AND PAVEMENT TO EXISTING IN GRADE AND ALIGNMENT.
8. CONTRACTOR SHALL MAINTAIN ALL EXISTING PARKING, SIDEWALKS,
DRIVES, ETC. CLEAR AND FREE FROM ANY CONSTRUCTION ACTIVITY
AND/OR MATERIAL TO ENSURE EASY AND SAFE PEDESTRIAN AND
VEHICULAR TRAFFIC TO AND FROM THE SITE.
5'
LOT 2A
2,950 S.F.
IN
OAK 5'
1C
LOT 12
MATCH E ISTING
CURB AND UTTER
EXISTING 18"
WILLOW OAK
TO. BE REMOVED
I
90.0' I !
_�� EXISTING TREES TO BE
MATCH EXISTING REMAIN AND PRESERVED
CURB AND GUTTER DURING CONSTRUCTION
WEST 13TH STREET
(ASPHALT/CONC. — 60' ROW)
---•-OHE--�--OHE---T—OHI�— a. _. __.. —
EXISTING
BUILDING —
LEGEND (EXISTING)
GRAPHIC SCALE IN FEET SYMBOLS LINEWORK
20' 0 20'
0 FOUND IRON PIN EASEMENT
LIGHT POLE ---------------------------------------------------------
1R POWER POLE CURB
m TELEPHONE PEDESTAL
TV PEDESTAL INTERMEDIATE CONTOUR
i O ..........
MANHOLE
INDEX CONTOUR
a SANITARY SEWER CLEANOUT ----s =—_--s-----s_
0 GAS METER SANITARY SEWER LINE
Da GAS VALVE----�__----—
GAS LINE
STORM SEWER PIPE
----w-----•------
�! DOWN GUY WATER LINE (SPECIFY SIZE & TYPE)
f Da WATER VALVE-----IICT------UCT
FIRE HYDRANT ASSEMBLY UNDERGROUND TELEPHONE
ce—um—
CONC.
PROPOSED � AIR RELEASE VALVE —ucE—i
DRIVEWAY UNDERGROUND ELECTRIC
FIRE DEPARTMENT CONNECTION MATCH EXISTING —0 �— E OT
ASPHALT 0 WATER METER OVERHEAD ELECTRIC
H— ® SPRINKLER HEAD ----- ry-----ury—
LLJ to ELECTRIC PEDESTAL UNDERGROUND TELEVISION
Cryry—
I' N OVERHEAD TELEVISION
GRATED INLET
Y- .......... ...
Q I CHAIN LINK FENCE
if 11
a —I II DROP INLET WOOD FENCE
0 N BARBED WIRE FENCE
N I Q TREE
FIBER OPTIC
RIGHT OF WAY
MATCH EXISTING �\ '' TREE TO BE REMOVED
CURB ND GUTIER ROAD CENTERLINE
PROPO
COCK. IDEWALK
ENGINEER'S NOTICE TO CONTRACTOR
THE EXISTENCE AND LOCATION OF ANY UNDERGROUND
UTILITY PIPES OR STRUCTURES SHOWN ON 114ESE DRAWINGS
ARE OBTAINED BY A SEARCH OF THE AVAILABLE RECORDS.
TO THE BEST OF OUR KNOWLEDGE THERE ARE NO EXISTING
UTILITIES EXCEPT AS SHOWN ON THESE DRAWINGS AND WE
ASSUME NO RESPONSIBILITY AS TO THE ACOURACY OF
THEIR DEPICTED LOCATION ON THESE DRAWINGS. THE
CONTRACTOR IS REQUIRED TO TAKE DUE PRECAUTIONARY
MEASURES TO PROTECT THE UTILITY LINES SHOWN, AND
ALL OTHER LINES NOT OF RECORD OR NOT SHOWN ON THESE
DRAWINGS BY VERIFICATION OF THEIR LOCATION IN THE
FIELD PRIOR TO THE INITIATION OF THE ACTUAL PORTION
OF THEIR WORK.
SAFETY NOTICE TO CONTRACTOR
IN ACCORDANCE WITH GENERALLY ACCEPTED CONSTRUCTION
PRACTICES, THE CONTRACTOR WILL BE SOLELY AND
COMPLETELY RESPONSIBLE FOR CONDITIONS OF THE JOB
SITE, INCLUDING SAFETY OF ALL PERSONS AND PROPERTY
DURING PERFORMANCE OF THE WORK. THIS REQUIREMENT
WILL APPLY CONTINUOUSLY AND NOT BE LIMITED TO
NORMAL WORKING HOURS.
THE DUTY OF THE ENGINEER TO CONDUCT CONSTRUCTION
REVIEW OF THE CONTRACTORS PERFORMANCE IS NOT
INTENDED TO INCLUDE REVIEW OF THE ADEQUACY OF THE
CONTRACTOR'S SAFETY MEASURES, IN, OR NEAR THE
CONSTRUCTION SITE.
OWNERSHIP OF DOCUMENTS
THIS DOCUMENT, AND THE IDEAS AND DESIGNS
INCORPORATED HEREIN, AS AN INSTRUMENT OF
PROFESSIONAL SERVICES, IS THE PROPERTY OF CRAFTON,
TULL & ASSOCIATES, INC., AND IS NOT TO BE
USED, IN WHOLE OR PART, FOR ANY OTHER PROJECT WITH
OUT THE WRITTEN AUTHORIZATION OF CRAFTON, TULL
& ASSOCIATES, INC.
NOTIFICATION OF LIMITED SERVICES
CRAFTON, TULL & ASSOCIATES, INC., (CTA) HAS
NOT BEEN RETAINED BY THE OWNER FOR CONSTRUCTION
ADMINISTRATION OR OBSERVATION SERVICES ON ALL OR A
PORTION OF THE WORK INDICATED ON THESE DRAWINGS.
THEREFORE, THE CTA HEREBY NOTIFIES ALL PARTIES
INVOLVED THAT THE CTA ASSUMES NO RESPONSIBILITY FOR
THE INTERPRETATION, COORDINATION AND ADMINISTRATION Of
THESE DOCUMENTS AND/OR DEVIATIONS THEREFROM AND THE
EFFECTS THOSE CHANGES MAY HAVE ON ANY AND ALL
RELATED TRADES OR CONSTRUCTION SEQUENCES, OR
OPERATION OF THE COMPLETED PROJECT, EXCEPT AS SPEC—
IFICALLY REQUIRED IN THE CTA's SERVICES AGREEMENT WITH
THE OWNER.
(le LEGEND (PROPOSED)
SYMBOLS
LINEWORK
•
SET IRON PIN
--------'-------------------
EASEMENT
LIGHT POLE
1R
POWER POLE
CURB
■
TELEPHONE PEDESTAL
1206
Is
TV PEDESTAL
INTERMEDIATE CONTOUR
Q
MANHOLE
1205
INDEX CONTOUR
0
SANITARY SEWER CLEANOUT
GAS METER
SANITARY SEWER LINE
N
GAS VALVE
,
O
STORM SEWER PIPE
GAS LINE
z-z
STRUCTURE NUMBER
IF
WATER LINE
►t
WATER VALVE
►�
FIRE HYDRANT ASSEMBLY
UNDERGROUND TELEPHONE
NN
AIR RELEASE VALVE
.=r
FIRE DEPARTMENT CONNECTION
UNDERGROUND ELECTRIC
•
WATER METER
OVERHEAD ELECTRIC
6
BACK FLOW PREVENTER
A
REDUCER
FIBER OPTIC
•
PLUG VALVE
—
uon
❑
GRATED INLET
UNDERGROUND TELEVISION
0mv ,,,,,
OVERHEAD TELEVISION
DROP INLET
CHAIN LINK FENCE
v gIG! ARC
D
�N
IL O
w Z
m ITT
WOOD FENCE
X -R X
BARBED WIRE FENCE
BUILDING SET BACK
RIGHT OF WAY
PROPERTY LINE
ROAD CENTERLINE
JUN 0 8 2015
10825 Financial Center Parkway, Suite 300
Little Rock, Arkansas 12211
Crafton Tull
® engineering i surveying
501.664.3245 t 501 .664.6704 f
www.craftontull.com
CERTIFICATE OF AUTHORIZATION , "
,,,,O,F, .AU,
CRAFTON, TULL &
ASSOCIATES, INC.
DZ No. 109
>y o=
gPrAN5A5 EIK+1�E¢�
VANN ADDITION
(A REPLAT OF THE SOUTH 501 OF
LOTS 7,819110,11 & 12 OF BLOCK
3, PARKADDITION TO THE CITY
OF LITTLE ROCK, PULASKI
COUNTY, ARKANSAS)
2284 WEST 13th STREET
LITTLE ROCK, AR
Key Plan
No. Descup6on Date
This document, and the ideas and designs incorporated herein,
as an instrument of professional service, is the property of
Crafton, Tull & Associates, Inc., and is not to be used, in whole
or in part, for any other project, without the written
authorization of Crafton, Tull & Associates, Inc.
N`'�POCTION
PROJECTNO: 118022-00 G°
ISSUEDATE: 04/06/11 �O� THIS F�
CONTACT: B.PETERSON DOCUMENT IS N
CHECKED BY: ° PRELIMINARY IN
NATURE AND IS NOT
PRELIMINARY w A FINAL, SIGNED o
PLANS N AND SEALED
DOCUMENT a°
c zoi i o-aJton, Tull & al Assoate:, Inc. 6 O°
°° NOIlOOd LSN
LAYOUT PLAN