Loading...
HomeMy WebLinkAboutZ-8646 Map 4IF -i II TI - i 1 I BLOCK 3 III ! III ! I PARK ADDITION v1 L I III I IIII TI I it I Ill LOT 7 ./ 1 9 LOT 10 II I II " III LOT 6 i LOT 9 I III \IF IIII I f II I IIII % i i I LOT 12 III I III IIII I / I it I I III I , EXISTING III III I // I I I I I BUILD NG LOT 11 I I II j I III II I EXISTING III Z II BUILDING III � E— O III I I II i O 6' WOOD zo III OZ II 70' j 6 PRIVAFENCY III Z II I 60 55' II I III QW I I I 7.5' SETBACK I 7.5' SETBACK 7 5' SETBACK II I III 30 I / 7.5' SETBACK III S I I Y; .0 30' 30' 7.5' SETBACK I Y I III I III Q Y h c z 30 ICI Ilj III m -- III LOT I ¢ m LOT 2 ' w" ¢ Y YLJ I i II III III / b 3,500 SF Ln rw 3,000 SIF / N / LOT 3 ¢ ¢ I a a a I Y I oz II (� Tn M ' �, ¢ n - m r7 3,000 SF 2, 50 SF rn / LOT 5 ¢ I L III / II z JII IIIIn III CONCRETE I n n Tn _ U �n n 2,750 SF � , DRIVEWAY III o¢ I I II III I I� I 7.5' SETBACK,' I I / 7.5' SETBACK ' _ N 1O 1-6 ETBACK I I II I JzI---------- ---- ___ - I 7.5' SETBACK 10' 10' S' SET3AC —W �'- - - - - - - - �CONC WA K - ----- % // -- f I L411 \�L—_______ !-----_ - �2 PVC WATERL W --- I----- CONC WALK W'. -----------'---_-- - - - ----- —_--_ - ----j----------- --- -- T CONCRETE ------------------ �-ff --- \___ WALK & O / STAIRS (TYP.) / % CONCRETE CONCRETE / CONCRETE WALK & DRIVEWAY I DRIVEWAY WEST 13TH STREET STAIRS (TYP.) --�• (ASPHALT/CONC. - 60' ROW) �-_-____----- _------ ,�� -------------- -- / OHE OHE •------- / I / _ — X ------ ` I EXISTING I i Q BUILDING r--'--- j-----------T — — — — — — — — — — — — — �� EXISTING I it t�i LEGEND (EXISTING) I II III SYMBOLS LINEWORK I II III —--- --- Ill 0 FOUND IRON PIN EASEMENT I II LIGHT POLE III------------------------ � III POWER POLE CURB IN o TELEPHONE PEDESTAL — -- -- -- ----1206— — — III INTERMEDIATE CONTOUR III E TV PEDESTAL Ill O MANHOLE --- III 'INDEX CONTOUR III a SANITARY SEWER CLEANOUT ,^ S III GAS METER SANITARY SEWER LINE Ij�II I D4 GAS VALVE GAS LINE G I O _ STORM SEWER PIPE W _ Ili E C DOWN GUY WATER LINE (SPECIFY SIZE & TYPE) I II pQ WATER VALVE -- U G T III FIRE HYDRANT ASSEMBLY UNDERGROUND TELEPHONE III UGE jL --- II! C8� AIR RELEASE VALVE UNDERGROUND ELECTRIC I II 16, FIRE DEPARTMENT CONNECTIA OHE �— III O WATER METER OVERHEAD ELECTRIC II SPRINKLER HEAD UGTV III m ELECTRIC PEDESTAL UNDERGROUND TELEVISION I II OHTV' ---- GRATED INLET OVERHEAD TELEVISION � Q � CHAIN LINK FENCE I II ii ,i DROP INLET I,' -- / III �L =—JJ WOOD FENCE III x x X - III/OBARBED WIRE FENCE _ F TREE V 171 1" / FIBER OPTIC FO i I II RIGHT OF WAY i III TREE TO BE REMOVED III ROAD CENTERLINE I II LEGEND (PROPOSED) III SYMBOLS LINEWORK -_- I II O • SET IRON PIN LIGHT POLE �- EASEMENT III �l POWER POLE CURB III ■ TELEPHONE PEDESTAL III / 0 TV PEDESTAL INTERMEDIATE CONTOUR � III 1205- MANHOLE � - - `- INDEX CONTOUR j) 0 SANITARY SEWER CLEANOUT SS III ! GAS METER SANITARY SEWER LINE II N GAS VALVE I / III I O STORM SEWER PIPE GAS LINE PARKING LOT / fli I OyF III O z-x STRUCTURE NUMBER W ►t WATER VALVE WATER LINE UGT FIRE HYDRANT ASSEMBL,Y � AIR RELEASE VALVE UNDERGROUND TELEPHONE UGE- /` FIRE DEPARTMENT CONNECTION UNDERGROUND ELECTRIC _ _ - III III • WATER METER —OHE _ I - III III B BACK FLOW PREVENTER OVERHEAD ELECTRIC ( FO REDUCER FIBER OPTIC I III II PLUG VALVE UGTV ----- r UNDERGROUND TELEVISION III IBM GRATED INLET OHTY --- - - ---- nI OVERHEAD TELEVISION � 'J �1 ` DROP INLET CHAIN LINK FENCE / t��! GENERAL NOTES SITE NOTES OWNER EVELOPER: WETLANDS NOTE: 4 wooD FENCE VANN & ASSOCIATES, LLC THE AREA OF THIS PROPOSED ADDITION IS P.O. BOX 164681 NOT LOCATED ON OR NEAR ANY KNOWN 1. ALL WORK AND MATERIALS SHALL COMPLY WITH ALL x --x-x------------- LITTLE ROCK, AR 72206 DESIGNATED WETLANDS. BUILDING SETBACKS: 1. ENGINEER'S NOTICE TO CONTRACTOR: THE EXISTENCE AND LOCATION OF CITY/COUNTY/STATE/FEDERAL REGULATIONS AND CODES AND OSHA ENGINEER'S NOTICE TO CONTRACTOR BARBED WIRE FENCE 501.351.1291 REQUIRED PROVIDED ANY UNDERGROUND UTILITY PIPES OR STRUCTURES SHOWN ON THESE STANDARDS THE EXISTENCE AND LOCATION OF ANY UNDERGROUND - FLOOD STATEMENT: DRAWINGS ARE OBTAINED BY A SEARCH OF THE AVAILABLE RECORDS. TO 2. CONTRACTOR SHALL REFER TO ARCHITECTURAL PLANS FOR EXACT UTILITY PIPES OR STRUCTURES SHOWN ON THESE DRAWINGS BUILDING SET BACK FRONT 15' 7.5' THE BEST OF OUR KNOWLEDGE THERE ARE NO EXISTING UTILITIES ARE OBTAINED BY A SEARCH OF THE AVAILABLE RECORDS. THERE ARE NO PORTIONS OF THE PROPERTY EX. SIDE -- 10 LOCATIONS AND DIMENSIONS OF VESTIBULES, SLOPE PAVING, To THE BEST of OUR KNOWLEDGE THERE ARE No ExlsTrraG INT. SIDE 5' 5' EXCEPT AS SHOWN ON THESE DRAWINGS AND WE ASSUME NO SIDEWALKS, EXIT PORCHES, TRUCK DOCKS, PRECISE BUILDING UTILITIES EXCEPT AS SHOWN ON THESE DRAWINGS AND WE PLATTED HEREON LYING WITHIN A SPECIAL RIGHT OF WAY CIVIL ENGINEER! SURVEYOR: RESPONSIBILITY AS TO THE ACCURACY OF THEIR DEPICTED LOCATION ON ASSUME PI RESPONSIBILITY AS TO THE ACCURACY E FLOOD HAZARD AREA, AS SHOWN ON FLOOD REAR 25' 7.5 DIMENSIONS AND EXACT UTILITY ENTRANCE LOCATIONS. CRAFTON, TULL & ASSOCIATES, INC. THESE DRAWINGS. THE CONTRACTOR IS REQUIRED TO TAKE DUE THEIR DEPICTED LOCATION TO THESE DRAWINGS THE INSURANCE RATE MAP PANEL N0. 3. ALL DIMENSIONS AND RADII ARE TO FACE/BACK OF CURB UNLESS CONTRACTOR IS REQUIRED TO TAKE DUE PRECAUTIONAR( PROPERTY LINE 10825 FINANCIAL CENTER PARKWAY, SUITE 300 PRECAUTIONARY MEASURES TO PROTECT THE UTILITY LINES SHOWN, AND LITTLE ROCK, AR 72211 0501810106E DATED OCTOBER 19, 2001 ALL OTHER LINES NOT OF RECORD OR NOT SHOWN ON THESE DRAWINGS OTHERWISE NOTED. ALL RES OTHER R LINESONOT TOF RECORD OR NOT SHOWN ON THESE®��� ,tea= 501.664.3245 FAX: 501.664.6704 BY VERIFICATION OF THEIR LOCATION IN THE FIELD PRIOR TO THE 4. ALL WORK SHALL BE DONE IN STRICT ACCORDANCE WITH THE PROJECT DRAWINGS BY VERIFICATION OF THEIR LOCATION IN THE ROAD CENTERLINE INITIATION OF THE ACTUAL PORTION OF THEIR WORK. SPECIFICATIONS. FIELD PRIOR TO THE INITIATION OF THE ACTUAL PORTION 2. SAFETY NOTICE TO CONTRACTOR: IN ACCORDANCE WITH GENERALLY 5. ALL CURB/SIDEWALK/HANDICAP RAMP DESIGNS SHALL CONFORM TO OF THEIR WORK. ARCHITECT: BUILDING SETBACKS: ACCEPTED CONSTRUCTION PRACTICES, THE CONTRACTOR WILL BE SOLELY ADA STANDARDS OR LOCAL RESTRICTIVE CODES, WHICHEVER IS MORE REQUIRED: 5 RESTRICTIVE. RPPY ARCHITECTS AND COMPLETELY RESPONSIBLE FOR CONDITIONS OF THE JOB SITE, 713 WEST SECOND STREET PROVIDED: 6 INCLUDING SAFETY OF ALL PERSONS AND PROPERTY DURING 6. CONTRACTOR SHALL ENSURE ALL NECESSARY PERMITS ARE OBTAINED SAFETY NOTICE TO CONTRACTOR LITTLE ROCK, APRIOR TO CONSTRUCTION START. R 72202 PERFORMANCE OF THE WORK. THIS REQUIREMENT WILL APPLY IN ACCORDANCE WITH GENERALLY ACCEPTED CONSTRUCTION 7. CONTRACTOR SHALL MATCH PROPOSED CURB AND GUTTER, CONCRETE, PRACTICES, THE CONTRACTOR WILL BE SOLELY AND 50i.372.0272 CONTINUOUSLY AND NOT BE LIMITED TO NORMAL WORKING HOURS. THE AND PAVEMENT TO EXISTING IN GRADE AND ALIGNMENT. COMPLETELY RESPONSIBLE FOR CONDITIONS OF THE JOB DUTY OF THE ENGINEER TO CONDUCT CONSTRUCTION REVIEW OF THE 8. CONTRACTOR SHALL MAINTAIN ALL EXISTING PARKING, SIDEWALKS, SITE, INCLUDING SAFETY OF ALL PERSONS AND PROPEITY LEGAL DESCRIPTION: CONTRACTOR'S PERFORMANCE IS NOT INTENDED TO INCLUDE REVIEW OF DURING PERFORMANCE OF THE WORK. THIS REQUIREMENT DRIVES, ETC. CLEAR AND FREE FROM ANY CONSTRUCTION ACTIVITY WILL APPLY CONTINUOUSLY AND NOT BE LIMITED TO THE SOUTH 50 FEET OF LOTS 10, 11 AND 12, THE ADEQUACY OF THE CONTRACTORS SAFETY MEASURES, IN, OR NEAR AND/OR MATERIAL TO ENSURE EASY AND SAFE PEDESTRIAN AND BLOCK 3, PARK ADDITION TO THE CITY OF THE CONSTRUCTION SITE. VEHICULAR TRAFFIC TO AND FROM THE SITE. LITTLE ROCK, PULASKI COUNTY, ARKANSAS. 3. OWNERSHIP OF DOCUMENTS: THIS DOCUMENT, AND THE IDEAS AND THE DUTY OF THE ENGINEER TO CONDUCT CONSTRUCTDN AND, THE SOUTH 50 FEET OF LOTS 7, 8 AND 9, DESIGNS INCORPORATED HEREIN, AS AN INSTRUMENT OF PROFESSIONAL REVIEW OF THE CONTRACTOR'S PERFORMANCE IS NOT BLOCK 3, PARK ADDITION TO THE CITY OF SERVICES, IS THE PROPERTY OF CRAFTON, TULL & ASSOCIATES, INC., CONTRDACDRTOSI NCLUDE SAFETY MEA RES, NE OREVIEW THR�NEAR T EQUAY "HE i q,Q LITTLE ROCK, PULASKI COUNTY, ARKANSAS. AND IS NOT TO BE USED, IN WHOLE OR PART, FOR ANY OTHER PROJECT DIG ' ' WITHOUT THE WRITTEN AUTHORIZATION OF CRAFTON, TULL NOTIFICATION OF LIMITED SERVICES -��� (CD & ASSOCIATES, INC. CRAFTON, TULL & ASSOCIATES, INC, (CTA) HAS ,r 7 4. CONTRACTOR SHALL NOT CAUSE ANY INCONVENIENCE TO THE PUBLIC, NOT BEEN RETAINED BY THE OWNER FOR CONSTRUCTION OWNERSHIP OF DOCUMENTS 0 ADJACENT PROPERTY OWNERS, PEDESTRIANS, ETC. DURING THE ADMINISTRATION OR OBSERVATION SERVICES ON ALL OR A G CONSTRUCTION OF THIS PROJECT. THE CONTRACTOR SHALL NOT PORTION OF THE WORK INDICATED ON THESE DRAWINGS. THIS DOCUMENT, AND THE IDEAS AND DESIGNS DISRUPT ACCESS TO ADJACENT PROPERTIES AT ANY TIME DURING INCORPORATED HEREIN, AS AN INSTRUMENT OF m ® z CONSTRUCTION. THEREFORE, THE CTA HEREBY NOTIFIES ALL PARTIES PROFESSIONAL SERVICES, IS THE PROPERTY OF CRAFON, INVOLVED THAT THE CTA ASSUMES NO RESPONSIBILITY FOR TULL & ASSOCIATES, INC., AND IS NOT TO BE 5. THE CONTRACTOR SHALL CONTACT THE ENGINEER FOR CLARIFICATION IF THE INTERPRETATION, COORDINATION AND ADMINISTRATION 0 USED, IN WHOLE OR PART, FOR ANY OTHER PROJECT NTH A DISCREPANCY OR INCONSISTENCY IS IDENTIFIED ON THE PLANS THESE DOCUMENTS AND/OR DEVIATIONS THEREFROM AND THE OUT THE WRITTEN AUTHORIZATION OF CRAFTON, TULL '� Q� ; h EFFECTS THOSE CHANGES MAY HAVE ON ANY AND ALL AND/OR SPECIFICATIONS. RELATED TRADES OR CONSTRUCTION SEQUENCES, OR 6. CONTRACTOR IS RESPONSIBLE FOR THE DESIGN AND IMPLEMENTATION OF OPERATION OF THE COMPLETED PROJECT, EXCEPT AS SPEC— 7 ALL REQUIRED/NECESSARY SHEETING, SHORING, AND SPECIAL IFICALLY REQUIRED IN THE CTA's SERVICES AGREEMENT WITH �8®C,y' EXCAVATION MEASURES REQUIRED ON THE PROJECT TO MEET OSHA, THE OWNER. FEDERAL, STATE AND LOCAL REGULATIONS. �- � Lil O LiJ C% O Q I d J I= _ n O Q Cn 10825 Financial Censer Pa'rway, Suite 300 Ldtle Rack, Arkansas 72211 rafton Tull ® engineering I surveying 501 664 3245 t 501 664 6704 f www craftontull com CERTIFICATE OF AUTHORIZATION •„o"""""""„n,,, A OP Off'=: `- CRAFTON, LULL & v- ASSOCIATES, INC Na IDP �O 4sf�M5A„ EFFaINEG4 i VANN ADDITION (A RELAT OV THE SOOTS 55" OF LOTS ', ,9,l0, € i & 11 OF BLOCK PART A I I )OIL O TF � CITY OF LI U LE ROCK, P� � SKI COUNTY, AR CAM , 2 24 13tl, �-T EE! _IT T I : ROCK, AR Key Plan Mo � C'as.rlFnoo Date This document, and the Ideas and designs Incorporated herein, as an instrument of professional service, is the property of Crafton, Tull & Associates, Inc, and is not to be used, in whole or in part, for any other project, without the written authorization of Crafton, Tull & Associates, Inc. ONS.t fLUOTiON PROTECT NO 118022-00 G R�L ISSUE DATE 1t/14/11 4O� THIS F� rnuTarT n DCTCRCnAI ,_ nirin IUF:MT IS CHECKED BY z° PRELIMINARY IN NATURE AND IS NOT PRELIMINARY w A FINAL, SIGNED o PLANS 3 AND SEALED DOCUMENT �a Crofton, Tull& Asscelates, Inc �6' 400 • �' NOIlOftt3lr' SITE PLAN