HomeMy WebLinkAboutZ-8629-C Staff AnalysisSUBDIVISION COMMITTEE COMMENTS
APRIL 19, 2017
ITEM NO.: 2. 102 S. RODNEY PARHAM MINI -WAREHOUSE
REVISED CONDITIONAL USE PERMIT
102 S. RODNEY PARHAM ROAD Z-8629-C
Planning Staff Comments:
1. There is no bill of assurance for this acreage tract
2. Is there a manager's apartment
3. Provide a signage plan
4. Provide days and hours of operation (office hours and hours of access to units).
5. Locate and describe all site lighting; including the parking lot and building lighting
6. Relocate dumpster away from adjacent residential lot
7. Will there be any outside storage of boats, RV's, trailers or other vehicles?
8. Provide exterior building elevations; including materials and colors
9. Provide a commitment that no businesses will be permitted to operate within the units.
10. Is there a prohibition against storage of flammable liquids and materials?
Variance/Waivers:
■ A variance from Section 36-522 to allow a 15' street buffer
• A variance from Section 36-301 to allow a building height of 37'
■ A variance from Section 36-522 to allow grading within the northern 15'of the southern land use
buffer
Public Works:
1. Rodney Parham St. is classified on the Master Street Plan as a minor arterial. A dedication of right-
of-way 45 feet from centerline will be required.
2. Repair or replace any curb and gutter or sidewalk that is damaged in the public right-of-way prior
to occupancy.
3. Storm water detention ordinance applies to this property if detention was provided with the last
development. Show the proposed location for stormwater detention facilities on the plan.
Maintenance of the detention pond and all private drainage improvements is the responsibility of
the developer and/or property owner's association.
4. If disturbed area is 1 or more acres, obtain a NPDES storm water permit from the Arkansas
Department of Environmental Quality prior to the start of construction.
5. A City of Little Rock drainage project was recently completed on both the north and south sides of
the Sunnymeade driveway. The 12 inch RCP on the north side of the Sunnymead driveway and
pipes downstream are believed to be undersized. At the time of the building permit, a drainage
analysis should be performed to determine if existing pipe sizes are adequate. If so, the system will
be required to be upsized.
6. With the proposed signage on the north side of the Rodney Parham driveway, the sight distance to
the west must not be obstructed.
7. Damage to public and private property due to hauling operations or operation of construction related
equipment from a nearby construction site shall be repaired by the responsible party prior to issuance
of a certificate of occupancy.
8. Stormwater pipes cannot be located under a building or structure.
ITEM NO.:2. (CON'T) (Z-8629-C)
Utilities and Fire Department/County Planning_
Little Rock Wastewater: Sewer available to this site. Existing easements must be retained.
Entergy: Entergy does not object to this proposal. There do not appear to be any conflicts with existing
power lines in the area. Contact Entergy in advance to discuss future service requirements, new
facilities locations and adjustments to existing facilities (if any) as this project proceeds.
Centerpoint Energy: No comments received.
AT&T: No comments received.
Central Arkansas Water: No objection
Fire Department:
Maintain Access:
Fire Hydrants.
Maintain fire apparatus access roads at fire hydrant locations as per Appendix D of the 2012 Arkansas Fire
Prevention Code Vol. 1 Section D103.1 Access road width with a hydrant. Where a fire hydrant is located
on a fire apparatus access road, the minimum road width shall be 26 feet, exclusive of shoulders.
Grade
Maintain fire apparatus access roads as per Appendix D of the 2012 Arkansas Fire Prevention Code Vol. 1
Section D103.2 Grade. Fire apparatus access roads shall not exceed 10 percent in grade except as approved
by the fire chief.
Loading
Maintain fire apparatus access road design as per Appendix D of the 2012 Arkansas Fire Prevention Code
Vol. 1 Section D102.1 Access and loading. Facilities, buildings or portions of buildings hereafter
constructed shall be accessible to fire department apparatus by way of an approved fire apparatus access
road with an asphalt, concrete or other approved driving surface capable of supporting the imposed load of
fire apparatus weighing at least 75,000 pounds.
30' Tall Buildings - Maintain aerial fire apparatus access roads as per Appendix D of the 2012
Arkansas Fire Prevention Code Vol. 1 Section D105.1— D105.4
D105.1 Where Required. Where the vertical distance between the grade plane and the highest roof
surface exceed 30', approved aerial fire apparatus access roads shall be provided. For the purposes of this
section the highest roof surfaces shall be determined by measurement to the eave of a pitched roof, the
intersection of a roof to the exterior wall, or the top of the parapet walls, whichever is greater.
ITEM NO.:2. CON'T Z-8629-C
D105.2 Width. Aerial fire apparatus access roads shall have a minimum unobstructed with of 26',
exclusive of shoulders, in the immediate vicinity of the building or portion thereof.
D105.3 Proximity to building. At least one of the required access routes meeting this condition
shall be located within a minimum of 15 feet and a maximum of 30 feet from the building, and shall be
positioned parallel to one entire side of the building. The side of the building on which the aerial fire
apparatus access road is positioned shall be approved by the fire code official.
D105.4 Obstructions. Overhead utility and power lines shall not be located over the aerial fire
apparatus access road or between the aerial fire apparatus road and the building. Other obstructions shall be
permitted to be places with the approval of the fire code official.
Gates
Maintain fire apparatus access road gates as per Appendix D of the 2012 Arkansas Fire Prevention
Code Vol. 1 Section D103.5 Fire apparatus access road gates. Gates securing the fire apparatus access
roads shall comply with all of the following criteria:
1. Minimum gate width shall be 20 feet.
2. Gates shall be of swinging or sliding type.
3. Construction of gates shall be of material that allow manual operation by one person.
4. Gate components shall be maintained in an operable condition at all times and replaces or repaired
when defective.
5. Electric gates shall be equipped with a means of opening the gate by fire department personnel for
emergency access. Emergency opening devices shall be approved by the fire code official.
6. Manual opening gates shall not be locked with a padlock or chain and padlock unless they are
capable of being opened by means of forcible entry tools or when a key box containing the keys to
the lock is installed at the gate location.
7. Locking device specifications shall be submitted for approval \by the fire code official
8. Electric gate operators, where provided, shall be listed in accordance with UL 325.
9. Gates, intended for automatic operation shall be designed, constructed and installed to comply with
requirements of ASTM F 2200.
Fire Hydrants
Locate Fire Hydrants as per Appendix C of the 2012 Arkansas Fire Prevention Code. Section C101 —
C105, in conjunction with Central Arkansas Water (Daniel Tull 501-377-1245) and the Little Rock Fire
Marshals Office (Capt. Tony Rhodes 501-918-3757 or Capt. John Hogue 501-918-3754). Number and
Distribution of Fire Hydrants as per Table C 105.1.
Building Codes:
Project is subject to full commercial plan review and approval prior to issuance of a building permit. For
information on submittal requirements and the review process, contact a commercial plans examiner:
Curtis Richey at 501.371.4724; crichey@littlerock.gov or
Mark Alderfer at 501.371.4875; malderfer@littlerock.go .
ITEM NO.:2. CON'T Z-8629-C
County Planning: No comments
Rock Region METRO:
a) Location is not currently served by METRO on routes 5 & 8 West Markham and Rodney Parham.
b) Because the location is within an existing neighborhood and well served by transit METRO does
not recommend supporting this use. Also there is a current business adjacent to this property in the
same block, Storage World. Approximately a 3/4 mile away two other similar businesses a U-Haul
storage & rental and U-Storit.
Plann-ing_Division: No comments
Landscape:
Site plan must comply with the City's minimal landscape and buffer ordinance requirements.
Street buffers will be required at six (6) percent of the average depth of the lot. The minimum
dimension shall be one-half (1/z) the full width requirement but in no case less than nine (9) feet. The
maximum dimension required shall be fifty (50) feet.
A land use buffer six (6) percent of the average width / depth of the lot will be required when an
adjacent property has a dissimilar use of a more restrictive nature. The adjacent property to the south
is zoned R-2. As a component of all land use buffer requirements, opaque screening, whether a fence
or other device, a minimum of six (6) feet in height shall be required upon the property line side of
the buffer. The plantings, existing and purposed, shall be provided within the landscape ordinance
of the city, section 15-102.
A perimeter planting strip is required along any side of a vehicular use area that abuts adjoining
property or the right-of-way of any street. One (1) tree and three (3) shrubs or vines shall be planted
for every thirty (30) linear feet of perimeter planting strip.
Screening requirements will need to be met for the vehicular use areas adjacent to street right-of-
ways. Provide screening shrubs with an average linear spacing of not less at three (3) feet within the
required landscape area. Provide trees with an average linear spacing of not less than thirty (30) feet.
Landscape areas shall be provided between the vehicular use area used for public parking and the
general vicinity of the building, excluding truck loading or service areas not open to public parking.
These areas shall be equal to an equivalent planter strip three (3) feet wide along the vehicular use
area.
An irrigation system shall be required for developments of one (1) acre or larger.
The City Beautiful Commission recommends preserving as many existing trees as feasible on this
site. Credit toward fulfilling Landscape Ordinance requirements can be given when preserving trees
of six (6) inch caliper or larger.
Other: Submit responses to staff issues and four (4) copies of a revised site plan (if required) no later than
Wednesday April 26, 2017. Required notices are to be sent via certified mail to all owners of properties
located within two hundred (200) feet of the site no later than Wednesday April 26, 2017. The City -provided
notice form must be used. Proof of notice is to be provided to staff no later than May 5, 2017.
May 11, 2017
ITEM NO.: 2 FILE NO.: Z-8629-C
NAME: 102 South Rodney Parham Mini -Warehouse —
Revised Conditional Use Permit
LOCATION: 102 South Rodney Parham Road
OWNER/APPLICANT: SS Rodney Parham, LLC/Marlar Engineering
PROPOSAL: A revision to a previously approved conditional use
permit is requested to allow for the construction of a
three-story, enclosed, mini -warehouse building on this
C-3 zoned 1.87± acre tract.
ITE LOCATION:
The property is located on the south (west) side of S. Rodney Parham
Road; one lot south of West Markham Street.
2. COMPATIBILITY WITH NEIGHBORHOOD:
The property is located within the commercial district at the West
Markham/Rodney Parham intersection. A Kroger store, Red Lobster and
Burger King are adjacent to the west. Additional commercial uses,
including an older, more traditional mini -warehouse development are
located beyond Kroger. A mixture of office and commercial uses are
located to the east and north. A single family neighborhood is adjacent to
the south. A restaurant previously occupied this site, with parking
extending to within a few feet of the southern boundary. In staff's opinion,
the nature of this proposed development and the specifics of the site
improvements are such that there could be a negative impact on the
adjacent single family neighborhood.
Notice of the public hearing was sent to all owners of properties located
within 200 feet of the site and the Sunnymeade and Briarwood
Neighborhood Associations.
3. ON SITE DRIVES AND PARKIN
Entrance to the site will be from a driveway onto Rodney Parham Road.
Exit from the site will be from that same driveway as well as from a
driveway onto Sunnymeade Drive. Twelve (12) parking spaces are
indicated outside of the gated area at the front of the property. Nine
(9) spaces are indicated within the access -controlled gated area of the site.
Two (2) spaces are located in the internal loading bay where customers
May 11, 2017
ITEM NO.: 2 (Cont.) _ FILE NO.: Z-8629-C
park to access the units. The facility is proposed to contain 750+ units of
mini -warehouse space.
4. SCREENING AND BUFFERS:
Site plan must comply with the City's minimal landscape and buffer
ordinance requirements.
Street buffers will be required at six (6) percent of the average depth of
the lot. The minimum dimension shall be one-half ('/2) the full width
requirement but in no case less than nine (9) feet. The maximum
dimension required shall be fifty (50) feet.
A land use buffer six (6) percent of the average width / depth of the lot
will be required when an adjacent property has a dissimilar use of a more
restrictive nature. The adjacent property to the south is zoned R-2. As a
component of all land use buffer requirements, opaque screening, whether
a fence or other device, a minimum of six (6) feet in height shall be
required upon the property line side of the buffer. The plantings, existing
and purposed, shall be provided within the landscape ordinance of the
city, section 15-102.
A perimeter planting strip is required along any side of a vehicular use area
that abuts adjoining property or the right-of-way of any street. One (1) tree
and three (3) shrubs or vines shall be planted for every thirty (30) linear feet
of perimeter planting strip.
Screening requirements will need to be met for the vehicular use areas
adjacent to street right-of-ways. Provide screening shrubs with an average
linear spacing of not less at three (3) feet within the required landscape
area. Provide trees with an average linear spacing of not less than thirty
(30) feet.
Landscape areas shall be provided between the vehicular use area used
for public parking and the general vicinity of the building, excluding truck
loading or service areas not open to public parking. These areas shall be
equal to an equivalent planter strip three (3) feet wide along the vehicular
use area.
An irrigation system shall be required for developments of one (1) acre or
larger.
The City Beautiful Commission recommends preserving as many existing
trees as feasible on this site. Credit toward fulfilling Landscape Ordinance
2
May 11, 2017
ITEM NO.: 2 (Cont.) FILE NO.: Z-8629-C
requirements can be given when preserving trees of six (6) inch caliper
or larger.
5. PUBLIC WORKS:
Rodney Parham St. is classified on the Master Street Plan as a minor
arterial. A dedication of right-of-way 45 feet from centerline will be
required.
2. Repair or replace any curb and gutter or sidewalk that is damaged in
the public right-of-way prior to occupancy.
3. Storm water detention ordinance applies to this property if detention
was provided with the last development. Show the proposed location
for stormwater detention facilities on the plan. Maintenance of the
detention pond and all private drainage improvements is the
responsibility of the developer and/or property owner's association.
4. If disturbed area is 1 or more acres, obtain a NPDES storm water
permit from the Arkansas Department of Environmental Quality prior
to the start of construction.
5. A City of Little Rock drainage project was recently completed on both
the north and south sides of the Sunnymeade driveway. The 12 inch
RCP on the north side of the Sunnymeade driveway and pipes
downstream are believed to be undersized. At the time of the building
permit, a drainage analysis should be performed to determine if existing
pipe sizes are adequate. If so, the system will be required to be upsized.
6. With the proposed signage on the north side of the Rodney Parham
driveway, the sight distance to the west must not be obstructed.
7. Damage to public and private property due to hauling operations or
operation of construction related equipment from a nearby construction
site shall be repaired by the responsible party prior to issuance of a
certificate of occupancy.
8. Stormwater pipes cannot be located under a building or structure.
6. UTILITY, FIRE DEPT. AND CATA COMMENTS:
Little Rock Wastewater: Sewer available to this site. Existing easements
must be retained.
Entergy: Entergy does not object to this proposal. There do not appear to
be any conflicts with existing power lines in the area. Contact Entergy in
advance to discuss future service requirements, new facilities locations
and adjustments to existing facilities (if any) as this project proceeds.
M
May 11, 2017
ITEM NO.: 2 (Cont.) FILE NO_ Z-8629-C
Centerpoint Energy: No comments received.
AT&T: No comments received.
Central Arkansas Water: No objection
Fire Department:
Maintain Access:
Fire Hydrants.
Maintain fire apparatus access roads at fire hydrant locations as per
Appendix D of the 2012 Arkansas Fire Prevention Code Vol. 1 Section
D103.1 Access road width with a hydrant. Where a fire hydrant is
located on a fire apparatus access road, the minimum road width shall be
26 feet, exclusive of shoulders.
Grade
Maintain fire apparatus access roads as per Appendix D of the 2012
Arkansas Fire Prevention Code Vol. 1 Section D103.2 Grade. Fire
apparatus access roads shall not exceed 10 percent in grade except as
approved by the fire chief.
Loading
Maintain fire apparatus access road design as per Appendix D of the
2012 Arkansas Fire Prevention Code Vol. 1 Section D102.1 Access and
loading. Facilities, buildings or portions of buildings hereafter constructed
shall be accessible to fire department apparatus by way of an approved
fire apparatus access road with an asphalt, concrete or other approved
driving surface capable of supporting the imposed load of fire apparatus
weighing at least 75,000 pounds.
30' Tall Buildings - Maintain aerial fire apparatus access roads as per
Appendix D of the 2012 Arkansas Fire Prevention Code Vol. 1
Section D105.1 — D105.4
D105.1 Where Required. Where the vertical distance between the grade
plane and the highest roof surface exceed 30', approved aerial fire
apparatus access roads shall be provided. For the purposes of this section
the highest roof surfaces shall be determined by measurement to the eave
of a pitched roof, the intersection of a roof to the exterior wall, or the top of
the parapet walls, whichever is greater.
D105.2 Width. Aerial fire apparatus access roads shall have a minimum
unobstructed with of 26', exclusive of shoulders, in the immediate vicinity
of the building or portion thereof.
2
May 11, 2017
ITEM NO.: 2 (Cont.
FILE NO.: Z-8629-C
D105.3 Proximity to building. At least one of the required access routes
meeting this condition shall be located within a minimum of 15 feet and a
maximum of 30 feet from the building, and shall be positioned parallel to
one entire side of the building. The side of the building on which the aerial
fire apparatus access road is positioned shall be approved by the fire code
official.
D105.4 Obstructions. Overhead utility and power lines shall not be
located over the aerial fire apparatus access road or between the aerial
fire apparatus road and the building. Other obstructions shall be permitted
to be places with the approval of the fire code official.
Gates
Maintain fire apparatus access road gates as per Appendix D of the
2012 Arkansas Fire Prevention Code Vol. 1 Section D103.5 Fire
apparatus access road gates. Gates securing the fire apparatus
access roads shall comply with all of the following criteria:
1. Minimum gate width shall be 20 feet.
2. Gates shall be of swinging or sliding type.
3. Construction of gates shall be of material that allow manual operation
by one person.
4. Gate components shall be maintained in an operable condition at all
times and replaces or repaired when defective.
5. Electric gates shall be equipped with a means of opening the gate by
fire department personnel for emergency access. Emergency opening
devices shall be approved by the fire code official.
6. Manual opening gates shall not be locked with a padlock or chain and
padlock unless they are capable of being opened by means of forcible
entry tools or when a key box containing the keys to the lock is
installed at the gate location.
7. Locking device specifications shall be submitted for approval \by the
fire code official
8. Electric gate operators, where provided, shall be listed in accordance
with UL 325.
9. Gates, intended for automatic operation shall be designed, constructed
and installed to comply with requirements of ASTM F 2200.
Fire Hydrants
Locate Fire Hydrants as per Appendix C of the 2012 Arkansas Fire
Prevention Code. Section C101 — C105, in conjunction with Central
Arkansas Water (Daniel Tull 501-377-1245) and the Little Rock Fire
Marshal's Office (Capt. Tony Rhodes 501-918-3757 or Capt. John Hogue
5
May 11, 2017
ITEM NO.: 2 (Cont.) FILE NO.: Z-8629-C
501-918-3754). Number and Distribution of Fire Hydrants as per Table
C105.1.
Building Codes
Project is subject to full commercial plan review and approval prior to
issuance of a building permit. For information on submittal requirements
and the review process, contact a commercial plans examiner:
a
Curtis Richey at 501.371.4724; cricheyCaDlittlerock.gov or
Mark Alderfer at 501.371.4875; malderfer littlerock. qov .
County Planning: No comments
Rock Region METRO:
a) Location is not currently served by METRO on routes 5 & 8 West
Markham and Rodney Parham.
b) Because the location is within an existing neighborhood and well served
by transit METRO does not recommend supporting this use. Also there
is a current business adjacent to this property in the same block, Storage
World. Approximately a % mile away two other similar businesses a
U-Haul storage & rental and U-Storit.
SUBDIVISION COMMITTEE COMMENT: (APRIL19, 2017)
The applicants were present. Staff presented the item. Staff noted the
requested buffer and building height variances. The applicant had been provided
a copy of staff comments and prepared the following responses.
1. There is no resident manager.
2. A signage plan will be prepared.
3. Office hours are 8.00 a.m. — 6:00 p.m., Monday through Saturday and tenant
access is 6:00 a.m. — 10:00 p.m. daily.
4. Building wall mounted lighting will be placed 9± feet above the finished floor
and wall pack lighting will be used near the loading dock area.
5. The dumpster is to be placed as indicated.
6. There will be outside storage of boats, RV's, trailers, watercraft or
automobiles.
7. The building exterior will be finished with architectural block, brick masonry,
decorative metal panels and EFTS.
8. No businesses will be permitted to be operated in the units.
0
May 11, 2017
ITEM NO.. 2 (Cont.) _ FILE NO,: Z-8629-C
9. No explosive, flammable, hazardous or other inherently dangerous materials
will be permitted to be stored in the facility.
Public Works Comments were discussed. Other Agency, Utility and Fire
Department Comments were presented. Landscape Comments were noted.
The applicants stated they were discussing the project with interested neighbors.
The Committee forwarded the item to the full Commission.
STAFF ANALYSIS:
The C-3 zoned, 1.8+ acre property located at 102 S. Rodney Parham Road was
previously occupied by a restaurant. The building was removed several years
ago. The site contains the vestiges of the parking lot.
On August 25, 2016, the Commission approved a conditional use permit to allow
for the construction of a three (3) story, conditioned, mini -warehouse facility on
the site. The facility was to contain approximately 750 units of mini -warehouse
space. The Commission's approval was appealed to the Board of Directors and,
on November 15, 2016, the Board upheld the Commission's action. The three
(3) story building had an exterior finish of split -faced block, brick and EIFS with
steel decorative panels. The colors were earth -toned. Access to the facility was
through a single garage door on the north (Rodney Parham) side of the building.
Customers would park in the building and after conducting their business, would
exit out of the south side. The "driveway" through the building was thirty (30) feet
wide and had enough room to park 30± vehicles. All access to the units was
from the interior of the building. Any units that had outside access were
eliminated. There were no windows on the south side of the building, facing the
adjacent single family residences. There was no access to Sunnymeade. That
driveway was gated and only served as Fire Department access. All customer
traffic exited the site directly onto Rodney Parham Road. The building itself had
a setback of sixty-five (65) feet from the south property line, adjacent to the
single family residences and fifty-three (53) feet from the east property line,
adjacent to two, C-3 zoned residences. Office hours were to be 9:00 a.m. to
6:00 p.m. Monday through Friday, 9:00 a.m. to 5:00 p.m. Saturday and noon to
5:00 p.m. on Sunday. Tenant access was to be 6:00 a.m. to 9:00 p.m. seven
days a week. The existing dumpster location on the north side of the
Sunnymeade Drive access drive was to be reused. There was to be no outside
storage of boats, RV's or trailers. No businesses were permitted to operate in
the facility and no storage of flammable materials was allowed. That facility has
not been constructed.
7
May 11, 2017
ITEM NO.: 2 (Cont.) FILE NO.: Z-8629-C
A different applicant is now requesting approval of a conditional use permit to
allow for construction of a somewhat different, three (3) story mini -warehouse
facility. The facility is also proposed to contain 750± units of mini -warehouse
space.
The proposed building is to have a setback of twenty-five (25) feet on the south
and east. The previous approval has setbacks of sixty-five (65) and fifty-three
(53) respectively. Access to the units is to be primarily from a two -space internal
loading bay. Nine (9) parking spaces are provided to allow some tenants to park
and carry their items in/out of the facility. No units will have direct outside
q/ access. The facility will be gated to control access. Tenants can exit the site
onto Sunnymeade Drive. The applicant intends to make modifications to the
Sunnymeade driveway to encourage tenants to make a left turn towards Rodney
Parham rather than a right turn into the neighborhood.
As under the previous proposal, the building is to be constructed of architectural
block and brick masonry, EIFS and decorative metal panels. The building will
have an earth tone finish and there will be no windows on the south side and
east side nearest the neighborhood.
Office hours are proposed as 8:00 a.m. to 6:00 p.m. Monday through Saturday
and tenant access is 6:00 a.m. to 10:00 p.m. daily. Lighting is proposed to
consist of wall mounted lighting placed nine (9) feet above the finished floor and
wall packs near the loading dock area. There will be no storage of boats, RV's,
trailers, watercraft or automobiles. No businesses will be permitted to operate in
the units and no explosive, flammable or inherently dangerous materials may be
stored in the facility.
The same three variances or similar approved under the previous application are
also requested under this new application. The first is a two feet height variance
to allow a building height of thirty-seven (37) feet. The prior approval allowed a
height of thirty-six (36) feet. C-3 has a height limit of thirty-five (35) feet. The
second variance is to allow a reduction in the Rodney Parham Road perimeter
street buffer from twenty-five (25) feet to fifteen (15) feet. The reduction is
caused, in part, by a requirement to dedicate additional right-of-way. The third
variance is to allow grading within the northern 15 feet of the southern land use
buffer. The Code allows an encroachment of up to 30% in a buffer. The
proposed 15 foot encroachment represents 60% of the buffer. That area
currently contains the vestiges of a paved parking lot.
While staff has previously stated support for placement of this type of facility on
this property, we do have concerns about aspects of this specific proposal.
May 11, 2017
ITEM NO.: 2 (Cont.) FILE NO.: Z-8629-C
This current proposal expands the building to the south and east to the minimum
building setback. The site is adjacent to single family residential and staff feels
the massing of the structure is such that it could negatively impact the adjacent
residences. The applicant proposes to utilize the driveway onto Sunnymeade as
a primary exit from the site. The issue of access to and from the site onto
Sunnymeade was a matter of great concern to the neighborhood under the prior
application. The dumpster has now been moved closer to the neighborhood by
placing it on the south side of the Sunnymeade access drive rather than on
the north side. This 750+ unit mini -warehouse facility is proposed to utilize a
two -space internal loading bay. Under the prior approval, the thirty (30) foot wide
driveway through the building provided a much greater number of internal
parking spaces for access to the units. Staff is concerned that under this
proposal, there is a greater likelihood of tenants having to park outside the facility
to access the units.
For these reasons, staff cannot support the current application
STAFF RECOMMENDATION. -
Staff recommends denial.
PLANNING COMMISSION ACTION: (MAY 11, 2017)
The applicants were present. There was one objector present. Staff presented
the item and a recommendation of denial.
Bear Davidson, of Marlar Engineering, addressed the Commission. He stated
this was a different applicant from the one who filed the first CUP application.
He stated this applicant was prepared to develop under the previously
approved plan but made the revisions to be more sensitive to concerns of the
neighborhood. Mr. Davidson said they had discussions with the neighborhood
and had reached out to individual neighbors. He said they were dropping the
building height variance request and would comply with the C-3 height limit.
Mr. Davidson addressed the changes from the previously approved plan. He
stated the drive through the building, exiting to the south, had been eliminated;
eliminating lights shining into the neighborhood and eliminating vehicle activity
in the area closest to the neighborhood. Mr. Davidson stated there were no site
security measures under the previous plan and this new plan had gates and
fencing to secure the site. He made note of the reduction in tenant parking and
stated the site would not generate more than 13-15 vehicles per day. He made
note of the vehicle access bay on the east side of the building. Lastly, he noted
the change in building massing and stated the height variance request was
being eliminated.
�7
May 11, 2017
ITEM NO-: Cont. FILE ND.- Z-8629-C
Michael Hall addressed the commission. He stated he had spoken directly with
Tracy Crain, President of the Sunnymeade Neighborhood, and had tried to
address her concerns. He said the neighborhood had expressed concern about
cut -through pedestrian traffic. He said a security fence would be installed to
prevent persons cutting through the site into the neighborhood. He said on -site
lighting would be reduced. Mr. Hall said he had spoken with another resident who
had requested more column -type evergreen trees at the rear of the site. He said
they would comply with this request as much as the City's landscape ordinance
would allow. Mr. Hall stated Ms. Crain had made it clear that the neighborhood
did not object to traffic from the site exiting onto Sunnymeade Drive as long as
the driveway was designed to encourage traffic to make a left turn towards
Rodney Parham rather than a right turn into the neighborhood. He said the
Sunnymeade exit was a secondary exit, not the primary exit and there would be
no signage on that driveway. Mr. Hall stated the dumpster had been placed
where indicated for ease of access for the garbage truck. He stated the
dumpster could be moved back to its previously approved location. Mr. Hall
stated he had tried on several occasions to make contact with the resident at
220 Sunnymeade but had been unable to do so. He said it appeared that the
C-3 zoned property was not being used as a residence as there were office
elements visible through the front window.
Ruth Bell, of the League of Women Voters of Pulaski County, spoke in opposition,
She stated the League had supported the previous plan but had concerns with
some aspects of this revised plan. She said the exit onto Sunnymeade should be
designed to be left turn only. She asked if the parking on the site would be
adequate for a 750 unit complex.
Mr. Hall stated this plan reduced noise and activity at the rear of the site, nearest
the neighborhood. He said they would install curbing, signs and bollards to
make vehicles exiting onto Sunnymeade turn left towards Rodney Parham. He
presented photos of the proposed interior loading/unloading bay and stated they
could accommodate four vehicles at a time.
In response to a question from Commissioner Dillon, staff stated the number of
units was the same under either plan, approximately 750.
Commissioner Bubbus commented that this proposed use would generate much
less traffic than a number of uses that could be developed on the C-3 zoned
property. He voiced his support for the item.
In response to questions from Commissioner May, Mr. Hall stated traffic has
never been an issue with this type of use.
It was clarified that the applicant had eliminated the height variance request, had
agreed to move the dumpster back to previously approved location on the north
side of the driveway and had agreed to make the necessary changes to the
10
May 11, 2017
ITEM NO.- 2 (Cont.) FILE NO.:_ Z=8629-C
Sunnymeade driveway to force vehicles exiting the site to turn left towards
Rodney Parham.
Chairman Berry noted there were only 8 commissioners present and, as a matter
of practice, offered the applicant an opportunity to defer to a later hearing. The
applicant stated he wished to go forward.
A motion was made to approve the application, as amended, including all staff
comments and conditions (except the recommendation of denial). The motion
was approved by a vote of 7 ayes, 1 noe and 3 absent.
11
May 11, 2017
ITEM NO.: 2 (Cont.) FILE NO.: Z-8629-C
A different applicant is now requesting approval of a conditional use permit to
allow for construction of a somewhat different, three (3) story mini -warehouse
facility. The facility is also proposed to contain 750± units of mini -warehouse
space.
The proposed building is to have a setback of twenty-five (25) feet on the south
and east. The previous approval has setbacks of sixty-five (65) and fifty-three
(53) respectively. Access to the units is to be primarily from a two -space internal
loading bay. Nine (9) parking spaces are provided to allow some tenants to park
and carry their items in/out of the facility. No units will have direct outside
access. The facility will be gated to control access. Tenants can exit the site
onto Sunnymeade Drive. The applicant intends to make modifications to the
Sunnymeade driveway to encourage tenants to make a left turn towards Rodney
Parham rather than a right turn into the neighborhood.
As under the previous proposal, the building is to be constructed of architectural
block and brick masonry, EIFS and decorative metal panels. The building will
have an earth tone finish and there will be no windows on the south side and
east side nearest the neighborhood.
Office hours are proposed as 8:00 a.m. to 6:00 p.m. Monday through Saturday
and tenant access is 6:00 a.m. to 10:00 p.m. daily. Lighting is proposed to
consist of wall mounted lighting placed nine (9) feet above the finished floor and
wall packs near the loading dock area. There will be no storage of boats, RV's,
trailers, watercraft or automobiles. No businesses will be permitted to operate in
the units and no explosive, flammable or inherently dangerous materials may be
stored in the facility.
t l 1 The same three variances 4r -similar approved under the previous application are
LL �1 also requested under this new application. The first is a two feet height variance
to allow a building height of thirty-seven (37) fe -approval-liow
7et,hy-six (36) feet. as gh I' it of thirty-five (35) feet. _T e (2
nce is to allow a reduction in the Rodney Parham Road perimet
from twenty-five (25) feet to fifteen (15) feet. The reductio
art, by a requirement to dedicate additional right-of-way. he thir
ar ow�gradrrYg-within the northern 1feetcf-tlie sou ern land us
bb ff`er The Code allows an encroachment of up to 30% in a buffer. The
proposed 15 foot encroachment represents 60% of the buffer. That area
currently contains the vestiges of a paved parking lot.
While staff has previously stated support for placement of this type of facility on
this property, we do have concerns about aspects of this specific proposal.
May 11, 2017
ITEM NO.: 2 (Cont.) FILE NO.: Z-8E29-CC
This current proposal expands the building to the south and east to the minimum
building setback. The site is adjacent to single family residential and staff feels
the massing of the structure is such that it could negatively impact the adjacent
residences. The applicant proposes to utilize the driveway onto Sunnymeade as
a primary exit from the site. The issue of access to and from the site onto
Sunnymeade was a matter of great concern to the neighborhood under the prior
application. The dumpster has now been moved closer to the neighborhood by
placing it on the south side of the Sunnymeade access drive rather than on
the north side. This 750+ unit mini -warehouse facility is proposed to utilize a
two -space internal loading bay. Under the prior approval, the thirty (30) foot wide
driveway through the building provided a much greater number of internal
parking spaces for access to the units. Staff is concerned that under this
proposal, there is a greater likelihood of tenants having to park outside the facility
to access the units.
For these reasons, staff cannot support the current application
STAFF RECOMMENDATION:
Staff recommends denial.
PLANNING COMMISSION ACTION: (MAY 11, 2017)
The applicants were present. There was one objector present. Staff presented
the item and a recommendation of denial.
Bear Davidson, of Marlar Engineering, addressed the Commission. He stated
this was a different applicant from the one who filed the first CUP application.
He stated this applicant was prepared to develop under the previously
approved plan but made the revisions to be more sensitive to concerns of the
neighborhood. Mr. Davidson said they had discussions with the neighborhood
and had reached out to individual neighbors. He said they were dropping the
building height variance request and would comply with the C-3 height limit.
Mr. Davidson addressed the changes from the previously approved plan. He
stated the drive through the building, exiting to the south, had been eliminated;
eliminating lights shining into the neighborhood and eliminating vehicle activity
in the area closest to the neighborhood. Mr. Davidson stated there were no site
security measures under the previous plan and this new plan had gates and
fencing to secure the site. He made note of the reduction in tenant parking and
stated the site would not generate more than 13-15 vehicles per day. He made
note of the vehicle access bay on the east side of the building. Lastly, he noted
the change in building massing and stated the height variance request was
being eliminated.