HomeMy WebLinkAboutZ-8559-C Staff Analysis.: Z-8559-C
NAME: Wildwood Place Revised Long -form PD-R
LOCATION: Located South of Denny Road on Wildcreek Circle
DEVELOPER:
Deltic Timber Corporation
7 Chenal Club
Little Rock, AR 72223
ENGINEER:
White-Daters and Associates
#24 Rahling Circle
Little Rock, AR 72223
AREA: 18.13 acres NUMBER OF LOTS: 82 FT. NEW STREET: 6,705 LF
WARD: 5 PLANNING DISTRICT: 21 —Burlingame Valley CENSUS TRACT: 42.02
CURRENT ZONING PD-R
ALLOWED USES: Single-family residential — Average 5,500 square foot lots
PROPOSED ZONING: Revised PD-R
PROPOSED USE: Add additional land area to the previously approved plat area
VARIAN C EMAIVERS: A variance from the Land Alteration Ordinance to allow grading
of the entire development area with the development of Phase VI.
BACKGROUND:
The Wildwood Park Subdivision is being developed under two (2) separate zoning case
files; File No. Z-8559 and File No. Z-8559-A. One phase of the subdivision is located on
the east side of an Entergy transmission line and the other phase is located on the west
side of the transmission line. The eastern development contains a total of 16.32 acres
and 67 lots and the western portion of the subdivision contains 43.41 acres and
184 lots. The total of the two (2) projects contains 59.73 acres and 251 lots. The
developments proposed the placement of pedestrian paths within the open space areas
to allow connection between two (2) phases of the subdivisions.
FILE NO.: Z-8559-C (Cont.
Ordinance 20,340 adopted by the Little Rock Board of Directors on October 19, 2010,
rezoned the eastern property from R-2, Single-family to PD-R, Planned Development
Residential. Ordinance No. 20,341 also adopted by the Little Rock Board of Directors on
October 19, 2010, rezoned this site, the western portion of the development, from
R-2, Single-family to PD-R, Planned Development Residential. The area to the east was
identified as Blocks 1 and 2 of the Wildwood Place Subdivision. This area was identified
as Blocks 3 through 7 Wildwood Place Subdivision.
All Corp. of Engineer's approvals, grading activity, the extension of water and sewer into
portions of this phase were completed with the initial phase of the subdivision. Street
construction, additional grading and drainage are currently under way within this portion
of the development. Blocks 1 and 2 have been fully developed and final platted.
Ordinance No. 21,312 adopted by the Little Rock Board of Directors on October 18, 2016,
allowed a revision to the previously approved PD-R, Planned Development Residential,
to allow the construction of a community/neighborhood park for the subdivision. The
neighborhood park was proposed with parking, pool house, two (2) pools, shade
structure, picnic area and playground area.
A. PROPOSAL/REQUEST/APPLICANT'S STATEMENT:
The applicant is now proposing to amend the previously approved PD-R, Planned
Development Residential for Phases 6 and 7 of the Wildwood Place Subdivision
to add additional land area and additional lots to the previously approved plat area.
The applicant is proposing to increase the number of lots for this development from
184 to 206. The lots are proposed with an average lot size of 50-feet by 110-feet.
The development is proposed with 4.75-acres of common open space within tracts.
The development is indicated with 20-foot front setbacks and 5-foot side yard
setbacks. The rear yard is proposed with a 25-foot setback.
B. EXISTING CONDITIONS:
Several phases of the subdivision have been final platted a new homes are being
constructed. To the west of the development area is Wildwood Center for the
Performing Arts. South of the site is undeveloped property owned by the current
applicant. There is a large transmission line, owned by Entergy located along the
western boundary of this development site.
C. NEIGHBORHOOD COMMENTS:
All property owners located within 200-feet of the site were notified of the public
hearing. There is not a neighborhood association registered with the City located
within this area.
K
FILE NO.: Z-8559-C Cont.)
D. ENGINEERING COMMENT
PUBLIC WORKS CONDITIONS:
A grading permit in accordance with Section 29-186 (c) and (d) will be
required prior to any land clearing or grading activities at the site. Other than
residential subdivisions, site grading and drainage plans must be submitted
and approved prior to the start of construction. Is an advanced grading permit
being requested to advance grade the lots with the construction of streets,
drainage, and utilities? Is an advanced grading permit being requested to
advance grade future phases with Phase VI?
2. Provide a Sketch Grading and Drainage Plan per Section 29-186 (e).
3. Stormwater detention ordinance applies to this property. Show the proposed
location for stormwater detention facilities on the plan. Maintenance of the
detention pond and all private drainage improvements is the responsibility of
the developer and/or local property owners association.
4. If disturbed area is one (1) or more acres, obtain a NPDES stormwater permit
from the Arkansas Department of Environmental Quality prior to the start of
construction.
5. Streetlights are required by Section 31-403 of the Little Rock code. Provide
plans for approval to Traffic Engineering. Streetlights must be installed
prior to platting/certificate of occupancy. Contact Traffic Engineering,
Greg Simmons, �simmonsCa littlerock.gav or 501.379.1813 for more
information.
6. Due to the number of lots being greater than 80, the Master Street Plan states
Wildcreek Circle should be constructed to a residential street standard within
a 50 foot right-of-way and sidewalk.
7. All public drainage easements must be unobstructed and access provided to
the public right-of-way by constructed infrastructure and/or documented on
the final plat.
8. All public drainage easements must contain drainage infrastructure approved
by the City of Little Rock Public Works Department.
9. 100 year overflow swales must be constructed and placed within public
drainage easements.
10. Traffic calming devices are required for long straight streets to discourage
speeding. Traffic circles or round-abouts are suggested at regular intervals
and at main intersections. Contact Traffic Engineering, Nat Banihatti,
nbanihatti(U),littllerock.gov or 501.379.1818 for additional information.
11. Pedestrian access is not shown to be provided to the revised phases of
development.
3
FILE NO.: Z-8559-C [Cont.
E. Utilities/Fire Department/Parks/County Planning:
Little Rock Water Reclamation Authority: Sewer main extension required with
easements if new sewer service is required for this project. Capacity fee analysis
required. Contact Little Rock Water Reclamation Authority for additional
information.
Entergy: Entergy Distribution does not object to this proposal. There do not
appear to be any conflicts with existing electrical Distribution lines based on the
information provided. There is an existing underground power line running along
Wildcreek Boulevard adjacent to this property in anticipation of this development.
The concern for this project may be with the 20 foot wide gravel path and
emergency access road which crosses under an Entergy Transmission line on the
northeast edge of the property. Contact the Transmission Department with
Entergy to determine if there are any issues related to this road to discuss
and resolve. Contact Entergy Distribution in advance to discuss electrical
service requirements, or adjustments to existing facilities (if any) as this project
proceeds.
Centerpoint Ener : No comment received.
AT & T: No comment received.
Central Arkansas Water:
1. All Central Arkansas Water requirements in effect at the time of request for
water service must be met.
2. Please submit plans for water facilities to Central Arkansas Water for review.
Plan revisions may be required after additional review. Contact Central
Arkansas Water regarding procedures for installation of water facilities.
Approval of plans by the Arkansas Department of Health Engineering Division
and the Little Rock Fire Department is required.
3. This development will have minor impact on the existing water distribution
system. Proposed water facilities will be sized to provide adequate pressure
and fire protection.
4. Additional fire hydrant(s) will be required. Contact the Little Rock Fire
Department to obtain information regarding the required placement of the
hydrant(s) and contact Central Arkansas Water regarding procedures for
installation of the hydrant(s).
5. If there are facilities that need to be adjusted and/or relocated, contact Central
Arkansas Water. That work would be done at the expense of the developer.
6. A Capital Investment Charge based on the size of meter connection(s) will
apply to this project in addition to normal charges.
CI
FILE NO.: Z-8559-C (Cont.l
Fire Department:
1. Fire Hydrants. Maintain fire apparatus access roads at fire hydrant locations
as per Appendix D of the 2012 Arkansas Fire Prevention Code Vol. 1 Section
D103.1 Access road width with a hydrant. Where a fire hydrant is located on a
fire apparatus access road, the minimum road width shall be 26 feet, exclusive
of shoulders.
2. Grade. Maintain fire apparatus access roads as per Appendix D of the 2012
Arkansas Fire Prevention Code Vol. 1 Section D103.2 Grade. Fire apparatus
access roads shall not exceed 10 percent in grade except as approved by the
fire chief.
3. Loading. Maintain fire apparatus access road design as per Appendix D of the
2012 Arkansas Fire Prevention Code Vol. 1 Section D102.1 Access and
loading. Facilities, buildings or portions of buildings hereafter constructed shall
be accessible to fire department apparatus by way of an approved fire
apparatus access road with an asphalt, concrete or other approved driving
surface capable of supporting the imposed load of fire apparatus weighing at
least 75,000 pounds.
4. Dead Ends. Maintain fire apparatus access roads at dead end locations as per
Appendix D of the 2012 Arkansas Fire Prevention Code Vol. 1 Section D103.4
Dead Ends. Dead-end fire apparatus access roads in excess of
150 feet shall be provided with width and turnaround provisions in accordance
with Table D103.4. Requirements for Dead-end fire apparatus access roads.
5. Electric gate operators, where provided, shall be listed in accordance with
UL 325.
6. Gates, intended for automatic operation shall be designed, constructed and
installed to comply with requirements of ASTM F 2200.
7. One- or Two -Family Residential Developments. As per Appendix D, Section
D107.1 of the Arkansas Fire Prevention Code Vol. 1, One- or Two -Family
dwelling residential developments. Developments of one- or two-family
dwellings where the number of dwelling units exceeds 30 shall be provided with
two separate and approved fire apparatus access roads, and shall meet the
requirements of Section D104.3.
1. Exceptions: Where there are more than 30 dwelling units on a single public
or private fire apparatus access road and al dwelling units are equipped
throughout with an approved automatic sprinkler system in accordance with
Section 903.3.1.1, 903.3.1.2 or 903.3.1.3 of the Arkansas Fire Code, access
from two directions shall not be required.
2. The number of dwelling units on a single fire apparatus access road shall
not be increased unless fire apparatus access roads will connect with future
development, as determined by the fire code official.
6. Fire Hydrants. Locate Fire Hydrants as per Appendix C of the
2012 Arkansas Fire Prevention Code. Section C101 — C105, in conjunction with
5
FILE NO.: Z-8559-C (Cont.
Central Arkansas Water (Jason Lowder 501.377.1245) and the
Little Rock Fire Marshal's Office (Capt. Tony Rhodes 501.918.3757 or
Capt. John Hogue 501.918.3754). Number and Distribution of Fire Hydrants as
per Table C105.1.
Parks and Recreation: No comment received.
County Planning: No comment.
F. Building Codes/Landscape-
Building Code: The 2012 AR Fire Prevention Code Vol. III for one (1) and
two (2) family dwellings requires foundations meet the following Sections of the
Code. If the foundation cannot be verified by the building official at the time of the
footing inspection the building official may require verification the foundation meets
the required elevation by a licensed engineer.
R403.1.7.3 Foundation elevation. On grade sites, the top of any exterior
foundation shall extend above the elevation of the street gutter at point of
discharge or the inlet of an approved drainage device a minimum of 12-inches (305
mm) plus two (2) percent.
R403.1.7.4 Alternate setback and clearances. Alternate setbacks and clearances
are permitted, subject to the approval of the building official. The building official is
permitted to require an investigation and recommendation of a qualified engineer
to demonstrate that the intent of this Section has been satisfied. Such an
investigation shall include consideration of materials, height of slope, slope
gradient, load intensity and erosion characteristics of slope material.
Please address any questions to the building inspectors at 501.371.4833 or
501.371.4834.
Note: Does not appear to meet fire access. One entrance to more than
30 residential properties.
Landscape: No comment-
G. Transportation/Planning:
Rock Region Metro: The site is not located on a dedicated Rock Region Metro
Route.
Planning Division: This request is located in Burlingame Valley Planning District.
The Land Use Plan shows Residential Low Density (RL) for this property. The
Residential Low Density is for single-family homes at densities no greater than six
(6) dwelling units per acre. The applicant has applied for a revised PD-R (Planned
9
FILE NO.: Z-8559-C (C
Development Resident) adding additional area (zoned R-2, Single-family) for
additional lots.
Master Street Plan: North of the property is Wildcreek Circle and it is a Local Street
on the Master Street Plan. The primary function of a Local Street is to provide
access to adjacent properties. Local Streets that are abutted by
non-residential zoning/use or more intensive zoning than duplexes are considered
as "Commercial Streets". A Collector design standard is used for Commercial
Streets. This street may require dedication of right-of-way and may require street
improvements for entrances and exits to the site.
Bicycle Plan: There are no bike routes shown in the immediate vicinity.
H. SUBDIVISION COMMITTEE COMMENT: (November 1, 2017)
Mr. Joe White of White-Daters and Associates was present representing the
request. Staff presented an overview of the item stating there were few
outstanding technical issues in need of addressing related to the proposed plat.
Staff requested Mr. White provide a plat which included the first five (5) phases of
the development.
Public Works comments were addressed. Staff stated a grading permit was
required prior to any site grading or land clearing. Staff requested the applicant
provide a sketch grading and drainage plan. Staff also stated if the disturbed area
was in excess of one (1) acres a NPDES stormwater permit was required. Staff
stated all public drainage easements were to contain drainage infrastructure
approved by the City. Staff stated due to the number of lots exceeding 80, the
Master Street Plan required Wildcreek Circle to be constructed as a residential
street standard with a 50-foot right of way and sidewalks.
Staff noted the comments from the various other departments and agencies. Staff
suggested the applicant contact the departments or agencies directly with any
questions or concerns. There were no more issues for discussion. The Committee
then forwarded the item to the full Commission for final action.
ANALYSIS:
The applicant submitted a revised preliminary plat/site plan to staff addressing the
technical issues associated with the request raised at the November 1, 2017,
Subdivision Committee meeting. The applicant has provided a plat/layout which
includes all phases of the proposed subdivision.
The request is to amend the previously approved PD-R, Planned Development
Residential for Phases 6 and 7 of the Wildwood Place Subdivision to add additional
land area and additional lots to the previously approved development area. The
applicant is proposing to increase the number of lots for this development from
184 to 206. The lots are proposed with an average lot size of 50-feet by 110-feet.
7
FILE NO.: Z-8559-C (Cont.
The development is indicated with 20-foot front setbacks and 5-foot side yard
setbacks. The rear yard is proposed with a 25-foot setback. The request includes
the allowance of accessory structures as typically allowed within the R-2, Single-
family Zoning District. The applicant is also indicating fences will be allowed as
per the R-2, Single-family Zoning District.
The Master Street Plan states Wildcreek Circle should be constructed to a
residential street standard within a 50 foot right-of-way and sidewalk. The Master
Street Plan states a Minor Residential Street is: (a) a cul-de-sac street not
exceeding 40 lots, or (b) a loop street not exceeding 80 lots, and (c) and in no case
generating more than 400 vehicle trips per day with the assumption of ten (10)
vehicle trips per day per lot. Typically the Minor Residential Street has a right-of-
way of 45 feet. The applicant is proposing to construct Wildcreek Circle to a
residential street standards with 26-feet between the curb faces. A sidewalk has
been extended southeasterly from Wildcreek Boulevard to a point where the
sidewalk connects to the pedestrian walk and path system. The applicant is
requesting a variance from the Master Street Plan to allow Wildcreek Circle to be
constructed as a minor residential street.
The request includes a variance from the Land Alteration Ordinance to allow
grading of the entire development area with the development of Phase VI. The
applicant indicates the variance request is necessary to allow the site to balance
and limit the need to haul materials from the site.
Staff is supportive of the applicant's request. The applicant is seeking approval to
revise the previously approved PD-R, Planned Development Residential, to allow
the creation of additional lots within the currently developing subdivision. The
development is proposed with 4.75-acres of common open space within tracts.
The density proposed for the subdivision is 4.53 units per acre. To staff's
knowledge there are no remaining outstanding technical issues associated with
the request. Staff feels the development as proposed is appropriate.
J. STAFF RECOMMENDATION:
Staff recommends approval of the request subject to compliance with the
comments and conditions as outlined in paragraphs D, E and F of the agenda staff
report.
Staff recommends approval of the variance request from the Land Alteration
Ordinance to allow grading of the entire development area with the development
of Phase VI.
Staff recommends approval of the variance request from the Master Street Plan to
allow Wildcreek Circle to develop as a minor residential street.
0
Z-8559-C (Cont.
PLANNING COMMISSION ACTION: (NOVEMBER 30, 2017)
The applicant was present. There were no registered objectors present. Staff presented
the with a recommendation of approval of the request subject to compliance with the
comments and conditions as outlined in paragraphs D, E and F of the agenda staff report.
Staff presented a recommendation of approval for the variance request from the Land
Alteration Ordinance to allow grading of the entire development area with the
development of Phase VI. Staff presented a recommendation of approval of the variance
request from the Master Street Plan to allow Wildcreek Circle to develop as a minor
residential street. There was no further discussion. The item was placed on the consent
agenda and approved as recommended by staff by a vote of 8 ayes, 0 noes and 3 absent.
ITEM NO.: 14.
NAME: Wildwood Place Revised Long -form PD-R
LOCATION: located South of Denny Road on Wildcreek Circle
Planning Staff Comments:
Z-8559-C
1. Provide notification of the property owners located within 200-feet of the site including the
certified abstract list, notice form with affidavit executed and proof of mailing. The notice
must be mailed no later than November 15, 2017. The Office of Planning and
Development must receive the proof of notice no later than November 24, 2017.
2. Provide an updated preliminary plat for this portion of the entire Chenal South
Subdivision.
Variance/Waivers: None requested.
Engineering Comments:
Public Works Conditions:
1. A grading permit in accordance with Section 29-186 (c) and (d) will be required prior to
any land clearing or grading activities at the site. Other than residential subdivisions, site
grading and drainage plans must be submitted and approved prior to the start of
construction. Is an advanced grading permit being requested to advance grade the lots
with the construction of streets, drainage, and utilities? Is an advanced grading permit
being requested to advance grade future phases with Phase VI?
2. Provide a Sketch Grading and Drainage Plan per Section 29-186 (e).
3. Stormwater detention ordinance applies to this property. Show the proposed location for
stormwater detention facilities on the plan. Maintenance of the detention pond and all
private drainage improvements is the responsibility of the developer and/or local property
owners association.
4. If disturbed area is one (1) or more acres, obtain a NPDES stormwater permit from the
Arkansas Department of Environmental Quality prior to the start of construction.
5. Streetlights are required by Section 31-403 of the Little Rock code. Provide plans for
approval to Traffic Engineering. Streetlights must be installed prior to platting/certificate of
occupancy. Contact Traffic Engineering, Greg Simmons, gsimmons cr�littlerock.gov or
501.379.1813 for more information.
6. Due to the number of lots being greater than 80, the Master Street Plan states Wildcreek
Circle should be constructed to a residential street standard within a 50 foot right-of-way
and sidewalk.
7. All public drainage easements must be unobstructed and access provided to the public
right-of-way by constructed infrastructure and/or documented on the final plat.
8. All public drainage easements must contain drainage infrastructure approved by the City
of Little Rock Public Works Department.
9. 100 year overflow swales must be constructed and placed within public drainage
ITEM NO.: 14.
Z-8559-C
easements.
10. Traffic calming devices are required for long straight streets to discourage speeding.
Traffic circles or round-abouts are suggested at regular intervals and at main
intersections. Contact Traffic Engineering, Nat Banihatti, nbanihatti@'littllerock.goy or
501.379.1818 for additional information.
11. Pedestrian access is not shown to be provided to the revised phases of development.
Utilities/Fire DepartmenVParks/County Planning:
Little Rock Water Reclamation Authority: Sewer main extension required with easements if
new sewer service is required for this project. Capacity fee analysis required. Contact Little
Rock Water Reclamation Authority for additional information.
Entergy: Entergy Distribution does not object to this proposal. There do not appear to be
any conflicts with existing electrical Distribution lines based on the information provided.
There is an existing underground power line running along Wildcreek Boulevard adjacent to
this property in anticipation of this development. The concern for this project may be with the
20 foot wide gravel path and emergency access road which crosses under an Entergy
Transmission line on the northeast edge of the property. Contact the Transmission
Department with Entergy to determine if there are any issues related to this road to discuss
and resolve. Contact Entergy Distribution in advance to discuss electrical service
requirements, or adjustments to existing facilities (if any) as this project proceeds.
Centerpoint Energy: No comment received.
AT & T: No comment received.
Central Arkansas Water:
1. All Central Arkansas Water requirements in effect at the time of request for water service
must be met.
2. Please submit plans for water facilities to Central Arkansas Water for review. Plan
revisions may be required after additional review. Contact Central Arkansas Water
regarding procedures for installation of water facilities. Approval of plans by the Arkansas
Department of Health Engineering Division and the Little Rock Fire Department is
required.
3. This development will have minor impact on the existing water distribution system.
Proposed water facilities will be sized to provide adequate pressure and fire protection.
4. Additional fire hydrant(s) will be required. Contact the Little Rock Fire Department to
obtain information regarding the required placement of the hydrant(s) and contact Central
Arkansas Water regarding procedures for installation of the hydrant(s).
5. If there are facilities that need to be adjusted and/or relocated, contact Central Arkansas
Water. That work would be done at the expense of the developer.
6. A Capital Investment Charge based on the size of meter connection(s) will apply to this
project in addition to normal charges.
ITEM NO.: 14. Z-8559-C
Fire Department:
1. Fire Hydrants. Maintain fire apparatus access roads at fire hydrant locations as per
Appendix D of the 2012 Arkansas Fire Prevention Code Vol. 1 Section D103.1 Access
road width with a hydrant. Where a fire hydrant is located on a fire apparatus access road,
the minimum road width shall be 26 feet, exclusive of shoulders.
2. Grade. Maintain fire apparatus access roads as per Appendix D of the 2012 Arkansas
Fire Prevention Code Vol. 1 Section D103.2 Grade. Fire apparatus access roads shall not
exceed 10 percent in grade except as approved by the fire chief.
3. Loading. Maintain fire apparatus access road design as per Appendix D of the 2012
Arkansas Fire Prevention Code Vol. 1 Section D102.1 Access and loading. Facilities,
buildings or portions of buildings hereafter constructed shall be accessible to fire
department apparatus by way of an approved fire apparatus access road with an asphalt,
concrete or other approved driving surface capable of supporting the imposed load of fire
apparatus weighing at least 75,000 pounds.
4. Dead Ends. Maintain fire apparatus access roads at dead end locations as per Appendix
D of the 2012 Arkansas Fire Prevention Code Vol. 1 Section D103.4 Dead Ends. Dead-
end fire apparatus access roads in excess of 150 feet shall be provided with width and
turnaround provisions in accordance with Table D103.4. Requirements for Dead-end fire
apparatus access roads.
5. Electric gate operators, where provided, shall be listed in accordance with UL 325.
6. Gates, intended for automatic operation shall be designed, constructed and installed to
comply with requirements of ASTM F 2200.
7. One- or Two -Family Residential Developments. As per Appendix D, Section D107.1 of the
Arkansas Fire Prevention Code Vol. 1, One- or Two -Family dwelling residential
developments. Developments of one- or two-family dwellings where the number of
dwelling units exceeds 30 shall be provided with two separate and approved fire
apparatus access roads, and shall meet the requirements of Section D104.3.
1. Exceptions: Where there are more than 30 dwelling units on a single public or private
fire apparatus access road and al dwelling units are equipped throughout with an
approved automatic sprinkler system in accordance with Section 903.3.1.1, 903.3.1.2
or 903.3.1.3 of the Arkansas Fire Code, access from two directions shall not be
required.
2. The number of dwelling units on a single fire apparatus access road shall not be
increased unless fire apparatus access roads will connect with future development, as
determined by the fire code official.
8. Fire Hydrants. Locate Fire Hydrants as per Appendix C of the 2012 Arkansas Fire
Prevention Code. Section C101 — C105, in conjunction with Central Arkansas Water
(Jason Lowder 501.377.1245) and the Little Rock Fire Marshal's Office (Capt. Tony
Rhodes 501.918.3757 or Capt. John Hogue 501.918.3754). Number and Distribution of
Fire Hydrants as per Table C105.1.
ITEM NO.: 14.
Z-8559-C
Parks and Recreation: No comment received.
County Planning_ No comment.
Building Codes/Landscape:
Building Code: The 2012 AR Fire Prevention Code Vol. III for one (1) and two (2) family
dwellings requires foundations meet the following Sections of the Code. If the foundation
cannot be verified by the building official at the time of the footing inspection the building
official may require verification the foundation meets the required elevation by a licensed
engineer.
R403.1.7.3 Foundation elevation. On grade sites, the top of any exterior foundation shall
extend above the elevation of the street gutter at point of discharge or the inlet of an
approved drainage device a minimum of 12-inches (305 mm) plus two (2) percent.
R403.1.7.4 Alternate setback and clearances. Alternate setbacks and clearances are
permitted, subject to the approval of the building official. The building official is permitted to
require an investigation and recommendation of a qualified engineer to demonstrate that the
intent of this Section has been satisfied. Such an investigation shall include consideration of
materials, height of slope, slope gradient, load intensity and erosion characteristics of slope
material.
Please address any questions to the building inspectors at 501.371.4833 or 501.371.4834.
Note: Does not appear to meet fire access
properties.
Landscape: No comment.
Transportation/Planning:
One entrance to more than 30 residential
Rock Region Metro: The site is not located on a dedicated Rock Region Metro Route.
Planning Division: This request is located in Burlingame Valley Planning District. The Land
Use Plan shows Residential Low Density (RL) for this property. The Residential Low Density
is for single-family homes at densities no greater than six (6) dwelling units per acre. The
applicant has applied for a revised PD-R (Planned Development Resident) adding additional
area (zoned R-2, Single-family) for additional lots.
Master Street Plan: North of the property is Wildcreek Circle and it is a Local Street on the
Master Street Plan. The primary function of a Local Street is to provide access to adjacent
ITEM NO.: 14. Z-8559-C
properties. Local Streets that are abutted by non-residential zoning/use or more intensive
zoning than duplexes are considered as "Commercial Streets". A Collector design standard is
used for Commercial Streets. This street may require dedication of right-of-way and may
require street improvements for entrances and exits to the site.
Bicycle Plan: There are no bike routes shown in the immediate vicinity.
Revised plat/plan: Submit four (4) copies of a revised preliminary plat/plan (to include the
additional information as noted above) to staff on Wednesday, November 8, 2017.