Loading...
HomeMy WebLinkAboutZ-8554 Map 2nnr� irnr nrnri in. N UA CL .z n GONGEPTUAL S 1 TE PLAN SCALE: I" = 20'-0" GRAPHIC SCALE 0 20 40 10 PARKIN& REQUIREMENTS: PROP05ED INDEPENDENT HOTEL LOT AREA 1.15 t ACRE TOTAL BLD6. AREA 1-1,100.00 S.F. PARKING REQUIRED 1.1 5PACE/ROOM UNIT= 55 SPACES PARKING FURNISHED 57 SPACES HC PARKIN& REQUIRED 1.2 SPACES (I VAN) HC PARKING PROVIDED 1 2 5PACE5 (2 VAN5) GENERAL NOTES: I. CONTRACTOR SHALL VERIFY ALL CONDITIONS AND DIMENSIONS AT THE JOB SITE AND NOTIFY THE ARCHITECT OF ANY DIMENSION ERRORS, OM15510N5 BEFORE FABRICATING ANY WORK. DO NOT SCALE DRAWIN65. 2. ALL CONSTRUCTION SHALL CONFORM TO THE REQUIREMENTS OF THE STANDARD SPECIFICATIONS OF THE CITY OF LITTLE ROCK, ARKANSAS. 5. CONTRACTOR SHALL PROVIDE "AS BUILT" PLANS TO THE ENGINEER 50 THAT THE REPRODUCIBLES OF THE EN6INEERIN& PLANS MAY BE CORRECTED TO REFLECT "AS BUILT" CONDITIONS. 4. THE CONTRACTOR SHALL BE REQUIRED TO PROVIDE AND MAINTAIN ALL NECESSARY WARNING AND SAFETY DEVICES (FLA5HIN6 LIGHTS, BARRICADE5, SIGNS, ETC) TO PROTECT THE PUBLIC SAFETY AND HEALTH UNTIL THE WORK HAS BEEN COMPLETED AND ACCEPTED BY THE CITY. 5. THE LOCATIONS OF EXI57IN6 UTILITIES SHOWN ON THESE PLANS ARE APPROXIMATE. IT 15 THE RESPONSIBILITY OF THE CONTRACTOR TO LOCATE AND VERIFY IN THE FIELD ANY UTILITIES THAT MAY CONFLICT WITH THIS CONSTRUCTION. AT LEAST 24 HOURS PRIOR TO 5E6INNIN6 CONSTRUCTION IN THE VICINITY OF UNDERGROUND UTILITIES, NOTIFY THE FOLLOWING APPLICABLE: \/ I C. IN I TY MAP SCALE : NONE LEGEND SANITARY SEWER MANHOLE STORM SEWER MANHOLE CLEAN OUT FIRE HYDRANT POWER POLE TELEPHONE BOX WATER METER GATE VALVE LIGHT POLE IRR16ATION SPRINKLER HEAD LOCATION VAN ACCE551BLE HANDICAP PARKING 516N LOCATION RIGHT OF WAY SET IRON ROD EXIST. L16HTPOLE DRAINAGE 8 UTILITY EASEMENT DRAINAGE FLOW ARROW TRAFFIC FLOW ARROW FOUND IRON ROD GAS METER EXIST. WATER VALVE PROPOSED SANITARY SEWER PIPE EX15TINO SANITARY SEWER PIPE PROPOSED WATER LINE EXISTING WATER LINE PROPOSED POWER LINE EX15TINO POWER LINE PROPOSED TELEPHONE LINE EXISTING TELEPHONE LINE PROPOSED 6A5 LINE EXI5TIN& 6A5 LINE PROP05ED STORM SEWER PIPE EXISTING STORM SEWER PIPE PROPOSED GUY WIRE EXI5TIN5 GUY WIRE OVERHEAD ELECTRICAL LINE EXISTING FIBER OPTICS CABLE 55 Q MH OO CO O FH PP 0/ TB ❑ NM &v E E_E T E_T GAS E_OAS — ST5 E_STS GW E_OA OHEL - TOO 11\VJLVI V,' ,VV, PROGRESSS PROJECT MANAGER: DAYNE RAM DESIGN MANAGER: RCM PROJECT DATE: XXX REVISION DATE: 031910 o G7 CD o Lo LLJ �co uP m y Q N c Z r-- m �� ago � N � Z Zrn Q N g � LL V / yy� gg AlA V c cm w 00oa) of -o Q Z N a It B !�/ a J W N N l U) w � Qa �-- o 0 J O Z w N Zoe � J U) Z zF-Z W vi W 0 1 0 Z CD ROCK PLANNING COMMISS10 S'JL :,CT TO Ty E CO'v^;TION .� by Ti� !_ Prf:P[P:�ii�G CO!u;MI5S10 F'UhD D k'ED " / �/d ' ':7 //0 — e��G-�yw,ps !�✓�-/ n U/ ZJ / `� —> 5 c� O u CD co c r' E s L 0) O X U W co �p0LoLLE U cl 0ja Lo Z Lo f i. L �cc) ILI � v E c'4 Y ^Y rn z_ a, E LL FL0 co p z `. Q 0) -1 = r.- 0- CL JOB NUMBER: XXX SHEET NUMBER CSP