Loading...
HomeMy WebLinkAboutZ-8554 Map 1N CONCEPTUAL S 1 TE PLAN SCALE: I" = 20'-0" GRAPHIC SCALE 0 20 40 10 PARKING REQUIREMENTS: PROPOSED INDEPENDENT HOTEL LOT AREA 1.15 t ACRE TOTAL BLDG. AREA 17,100.00 S.F. PARKING REQUIRED 1.1 5PACE/ROOM UNIT= 55 SPACES PARKING FURNISHED 57 SPACES HC PARKING REQUIRED 2 SPACES (I VAN) HC PARKING PROVIDED 2 SPACES (2 VANS) VICINITY MAF 51TE GENERAL NOTES: I. CONTRACTOR SHALL VERIFY ALL CONDITIONS AND DIMENSIONS AT THE JOB SITE AND NOTIFY THE ARCHITECT OF ANY DIMENSION ERRORS, OMISSIONS BEFORE FABRICATING ANY WORK. DO NOT 50ALE PRAWIN65. 2. ALL CONSTRUCTION SHALL CONFORM TO THE REQUIREMENTS OF THE STANDARD SPECIFICATIONS OF THE CITY OF LITTLE ROCK, ARKANSAS. 5. CONTRACTOR SHALL PROVIDE "AS BUILT" PLANS TO THE ENGINEER 50 THAT THE REPRODUCIBLES OF THE ENGINEERING PLANS MAY BE CORRECTED TO REFLECT "AS BUILT" CONDITIONS. 4. THE CONTRACTOR SHALL BE REQUIRED TO PROVIDE AND MAINTAIN ALL NECESSARY WARNING AND SAFETY DEVICES (FLASHING LIGHTS, BARRICADES, SIGNS, ETC,.) TO PROTECT THE PUBLIC SAFETY AND HEALTH UNTIL THE WORK HAS BEEN COMPLETED AND ACCEPTED BY THE CITY. 5. THE LOCATIONS OF EXISTING UTILITIES SHOWN ON THESE PLANS ARE APPROXIMATE. IT 15 THE RESPONSIBILITY OF THE CONTRACTOR TO LOCATE AND VERIFY IN THE FIELD ANY UTILITIES THAT MAY CONFLICT WITH THIS CONSTRUCTION. AT LEAST 24 HOURS PRIOR TO BEGINNING CONSTRUCTION IN THE VICINITY OF UNDERGROUND UTILITIES, NOTIFY THE FOLLOWING APPLICABLE: T 5CALE : NONE LEGEND SANITARY SEWER MANHOLE 55 Q STORM SERER MANHOLE MH pO GLEAN OUT GO O FIRE HYDRANT FH -♦- POWER POLE PP 0 TELEPHONE BOX TB WATER METER WM GATE VAL`/r GV v LIGHT POLE IRRIGATION SPRINKLER O HEAD LOCATION VAN ACCESSIBLE HANDICAP PARKING SIGN LOCATION RIGHT OF WAY R.O.W. SET IRON ROD S.I.R. EXIST. LIGHTPOLE DRAINAGE 8 UTILITY DE/UE EASEMENT DRAINAGE FLOW ARROW TRAFFIC FLOW ARROW m* FOUND IRON ROD F.I.R. GAS METER GM ❑ EXIST. WATER VALVE O PROPOSED 55 SANITARY SEWER PIPE EXISTING E_55 SANITARY 5EWER PIPE PROPOSED w WATER LINE EXISTING E-.a WATER LINE PPIOP05ED E POWER LINE EXISTING E-E POWER LINE PROPOSED T TELEPHONE LINE EXISTING E-T — TELEPHONE LINE PROPOSED GAs GAS LINE EXISTING E-OA3 GAS LINE PROPOSED ST5 STORM SEWER PIPE EXISTING E_STS STORM SEWER PIPE PROPOSED GUY WIRE 6w EXISTING GUY WIRE E_ew OVERHEAD ELECTRICAL OHEL LINE EXISTING FIBER FOG OPTICS CABLE rl\VJLVI VIIIIVV. PROGRESS PROJECT MANAGER: DAYNE RAM DESIGN MANAGER: RCM PROJECT DATE: XXX REVISION DATE: 031910 o G7 C) o Lo Lu (� L m Q E2 N N c� v g z N0 O V � N L) z LL N LA� co m 1^`p W O LL I 9� zC'4co G J ¢ co (j rn O ¢=w a o 0 J 5 O z w Q Y N Z 65O� � J (¢/J Z Z F z Lu Q W o Q Z �... /V�:n✓4[.1. M u, u p o M -CC; s .-. N s. E O J � tje L I ? oo LL E CC, L - ;f Z � O T- i, � fn o0 m N S 'G E w w Lo Z~�E1i s c' FL (oJ 1 << M Z Ind �WLL JOB NUMBER: xXx SHEET NUMBER CSP