HomeMy WebLinkAboutZ-8445 Staff AnalysisFILE NO.: Z-8445
NAME: C Street Surgery Center Short -form PD-O
LOCATION: Located at 5910 C Street
DEVELOPER:
University Properties
409 North University Avenue
Little Rock, AR 72205
ENGINEER/SURVEYOR:
White-Daters and Associates
24 Rahling Circle
Little Rock, AR 72223
AREA: 0.45 acres NUMBER OF LOTS: 1 Zoning Lot
CURRENT ZONING: R-3, Single-family
ALLOWED USES: Single-family Residential
PROPOSED ZONING: PD-O
PROPOSED USE: Surgery Center
OVERLAY DISTRICT: Mid -Town Design Overlay District
VARIANCESM/AIVERS REQUESTED: None requested.
A. PROPOSAL/REQUEST:
FT. NEW STREET: 0 LF
The property is located near the intersection of C Street and University Avenue.
The property currently contains two occupied single-family residences. The
developers are seeking a rezoning of the property to allow the removal of the
homes and the construction of a new 8,780 square foot survey center. The
center will contain four (4) operating rooms and ten (10) prep and recovery
rooms. Two (2) doctors will operate from the facility.
The proposal includes an existing parking lot located immediately west of this
property. The doctors currently own this parking lot and intend to utilize this
parking area as the required parking for the surgery center. The parking lot
contains 35 parking spaces. The applicant is proposing to only include one-half
FILE NO.: Z-8445 (Cont.
of the parking lot with the application request resulting in 19 on -site parking
spaces. A parking lot located to the south of the site is proposed to provide
parking for staff. The off -site parking provided is 40 spaces.
B. EXISTING CONDITIONS:
There are occupied single-family homes located on the two lots proposed for
rezoning. The parking lot area located to the west of the two homes is currently
zoned R-3, Single-family and is also proposed for rezoning as a part of this
PD-O. To the north are single-family homes and to the east are two additional
homes. An area zoned PD-O located north of the parking lot has been
developed as parking to serve the doctors offices to the west. South of the site is
the Mid-towne Shopping Center and southeast are single-family homes and
multi -family housing. West of the site is a parking area serving the medical
offices fronting North University Avenue.
NEIGHBORHOOD COMMENTS:
As of this writing, staff has received several informational phone calls from area
residents. All property owners located within 200 feet of the site, all residents,
who could be identified, located within 300 feet of the site and the Hillcrest
Residents Association were notified of the public hearing.
D. ENGINEERING COMMENTS:
PUBLIC WORKS CONDITIONS:
1. Due to the proposed use of the property, the Master Street Plan specifies
that C Street for the frontage of this property must meet commercial street
standards. Dedicate right-of-way to 30 feet from centerline.
2. With site development, provide the design of street conforming to the
Master Street Plan. Construct one-half street improvement to C Street
including
5-foot sidewalk with the planned development. The new back of curb
should be located 18 feet from the centerline of the street and match the
curb of the property to the west.
3. Repair or replace any curb and gutter or sidewalk that is damaged in the
public right-of-way prior to occupancy.
4. Plans of all work in right-of-way shall be submitted for approval prior to start
of work. Obtain barricade permit prior to doing any work in the right-of-way
from Traffic Engineering at (501) 379-1805 (Travis Herbner).
5. A grading permit in accordance with Section 29-186 (c) and (d) will be
required prior to any land clearing or grading activities at the site. Other
than residential subdivisions, site grading and drainage plans must be
submitted and approved prior to the start of construction.
P"
FILE NO.: Z-8445
6. A Sketch Grading and Drainage Plan should be provided per Section
29-186 (e).
7. Measures to control an increase in stormwater drainage should be
implemented to not cause damage onto adjacent property from the
increased impervious area.
8. Provide the direction of flow and all stormwater flows (Q) entering and
leaving the property.
9. Street improvement plans shall include signage and striping. Traffic
Engineering must approve completed plans prior to construction.
10. The circle drive should be one way. Enter from the east driveway and exit
on the west driveway.
E. UTILITIES AND FIRE DEPARTMENT/COUNTY PLANNING:
Wastewater: Sewer available to this project.
Entergy: Approved as submitted.
Center -Point Energy: No comment received.
AT & T: No comment received.
Central Arkansas Water: All Central Arkansas Water requirements in effect at
the time of request for water service must be met. A water main extension and
additional fire hydrant(s) will be required to provide adequate fire protection to
this facility. Due to the nature of this facility, installation of an approved reduced
pressure zone backflow preventer assembly (RPZ) is required on the domestic
water service. This assembly must be installed prior to the first point of use.
Central Arkansas Water (CAW) requires that upon installation of the RPZA,
successful tests of the assembly must be completed by a Certified Assembly
Tester licensed by the State of Arkansas and approved by CAW. The test results
must be sent to CAW's Cross Connection Section within ten days of installation
and annually thereafter. Contact the Cross Connection Section at 377-1226 if
you would like to discuss backflow prevention requirements for this project.
Fire Department: Additional fire hydrants maybe required. Contact Little Rock
Fire Department for additional information.
County Planning: No comment.
CATA: The site is not located on a dedicated CATA Bus Route.
3
FILE NO.: Z-8445 Cont.
F. ISSUES/TECHNICAL/DESIGN:
Planning Division: This request is located in the Heights Hillcrest Planning
District. The Land Use Plan shows Multi Family for this property. The applicant
has applied for a rezoning from R-3, Single-family to Planned Development
Office to allow the construction of a medical office/surgery center.
A Land Use Plan amendment (LU09-04-01) a change from Multi Family to Office
is a separate item on this agenda.
Master Street Plan: C Street is shown as a Local Street. The primary function of
a Local Street is to provide access to adjacent properties. Local Streets which
are abutted by non-residential zoning/use or more intensive zoning than
duplexes are considered as "Commercial Streets". These streets have a design
standard the same as a Collector. These streets may require dedication of
right-of-way and may require street improvements for entrances and exits to the
site.
Bicycle Plan: There are no bike routes in the immediate vicinity.
Neighborhood Action Plan- This area is covered by the Hillcrest Neighborhood
Plan. Their Zoning and Land Use goal states: "Adopt a plan of action to stop the
degradation, to reverse its course, and to recreate a neighborhood that is once
again a pleasant place to work and live. This includes no net loss of residential
units by demolition or conversion to other uses."
Landscape:
1. An eleven foot seven inch (117') foot land use buffer is required along the
northern perimeter of the site. A six foot nine inch (69") land use buffer is
required along the sites eastern perimeter. Easements cannot count toward
full -filling this requirement. Seventy percent (70%) of the buffer area is to
remain undisturbed.
2. The landscape ordinance requires a minimum of eight percent (8%) of the
paved areas be landscaped with interior islands of at least seven and one-half
(7 '/2) feet in width. Interior islands must be a minimum of one hundred and
fifty (150) square feet in area to qualify towards the minimum landscape
ordinance requirements.
3. Street trees are required per the Mid -town DOD. Street trees shall be a
minimum of three-inch caliper and shall be two (2) feet off the back of curb,
thirty (30) feet on center. The canopy shall be maintained with an eight -foot
clearance. A four -foot planter strip shall be maintained.
4. A street buffer of six feet nine inches (6'9") is required adjacent to the
proposed building construction site in accordance with the Landscape
Ordinance.
►I
FILE NO.: Z-8445 (Cont.
5. The landscape ordinance requires a minimum landscape strip of three feet (3)
to be located between the parking lot and the building.
6. A six (6) foot high opaque screen, either a wooden fence with its face side
directed outward, a wall, or dense evergreen plantings, is required along the
northern and eastern perimeters of the site. Credit towards fulfilling this
requirement can be given for existing trees and undergrowth that satisfies this
year -around requirement.
G. SUBDIVISION COMMITTEE COMMENT- (April 9, 2009)
Mr. Joe White of White-Daters and Associates was present representing the
request. Staff presented an overview of the request stating there were additional
items necessary to complete the review process. Staff stated the site was
located within the Mid -Town Design Overlay District. Staff requested
development information related to the DOD standards to establish the areas of
compliance with the DOD. Staff noted any variation from the DOD was to be
approved by the Planning Commission and the Board of Directors through the
adoption of the ordinance and the site plan for the development. Staff noted the
parking lot located to the east of the surgery center was to also be included in the
overall review. Staff requested the legal description of the parking lot be added
to the site plan and survey.
Public Works comments were addressed. Staff stated there were drainage
concerns from the existing parking lot and the sheet flow of water onto the
adjacent property owners. Staff requested Mr. White provide the direction of flow
and all storm water flows entering and leaving the property. Staff also requested
Mr. White provide a sketch grading and drainage plan. Staff stated the circle
drive indicated on the site plan be a one-way drive. Staff stated the drive should
enter from the east and exit on the west.
Landscaping comments were addressed. Staff stated screening was required
along the northern and eastern perimeters of the site. Staff stated a small
amount of building landscaping would be required. Staff noted street trees would
be required per the Mid -Town DOD.
Staff stated the generator was shown on the north side of the building adjacent to
the single-family zoned and used property. Staff requested limits be placed on
the hours of testing the generator similar to the limits placed on the dumpster
hours of service.
Staff noted comments from the other reporting departments and agencies
suggesting the applicant contact them individually for additional clarification.
There was no further discussion of the item. The Committee then forwarded the
item to the full Commission for final action.
5
FILE NO.: Z-8445 (Cont.
R ANALYSIS:
The applicant submitted a revised cover letter and site plan to staff addressing a
number of the issues raised at the April 9, 2009, Subdivision Committee meeting.
The revise plan indicates the east one-half of the parking lot located on the west
side of the proposed surgery center to be included in the proposed rezoning
request. Staff feels the entire parking lot should be included in the rezoning
request. The drive is a two-way drive and it will be difficult to separate patient
and staff parking. The parking lot is zoned R-3, Single-family and was approved
by the Board of Adjustment for construction of the parking lot a number of years
ago. The parking lot was not constructed until three years ago. The rezoning of
the entire parking lot along with this request will bring continuity to the zoning of
this area.
The applicant has provided a sketch grading and drainage plan. The plan
indicates predevelopment and post -development water flows. On the north side
of the property the Q25 Undeveloped is 2.9 cfs and the Q25 Developed is 1.9 cfs.
On C Street the Q25 Undeveloped is 1.2 cfs and the Q25 Developed is 3.0 cfs.
The developer has indicated all roof drains will be routed to C Street. The site
plan indicates the flume located on the western parking lot will be redirected to
allow the water to flow eastward and be swaled in order to disperse the water in
an even manner rather than a single point of discharge.
The drive in front of the building is indicated as a one-way drive as requested by
Public Works staff. The drive width will allow for two lanes to allow passing and
not require automobiles to stack in the driveway.
The revised site plan has not relocated the generator from the north face of the
building. The hours of generator service have been limited to daylight hours and
most likely be on Wednesday at noon. Staff feels the limits of generator service
should be limited to the hours indicated by the applicant.
The development is proposed with construction of a new surgery center
containing 8,870 square feet. The total landscaped area proposed is
12,225 square feet or 38.2 percent of the site. The paved area proposed is
11,035 square feet or 34.4 percent of the site. Two doctors will operate from the
facility. There are two operating rooms proposed and ten prep and recovery
rooms. The applicant has indicated the east one-half of an existing parking lot
containing 19 parking spaces to serve the surgery center. The hours of operation
are from 7 am to 5 pm daily.
The property being considered for rezoning is located within the Mid -town Design
Overlay District. The ordinance has various development standards related to
building setbacks, heights, construction materials and building appearances.
The facade treatment for new construction requires a minimum of 60 percent of
the ground floor level facing internal pedestrian public circulation areas or streets
l
FILE NO.: Z-8445 (Cont.
be glass -windows, entry features or displays. The applicant has indicated
40 percent of the front of the building will be glassed. The intent of the developer
is to construct an office building with a residential flair. According to the
developers to meet this goal it is difficult to provide 60 percent of the facade with
glass features. The primary fagade of the building will be oriented parallel to the
street. The building is proposed as a singe story building. No wall projections or
recesses are proposed on the structure along the sides or rear wall. The front of
the building will have a projection extending to a covered canopy to be used for
patient drop-off and pick-up. The sides of the building is proposed 108 liner feet.
The building is not proposed with breaks in the building to visually break the
mass since the structure is so close to the 100-foot standard established by the
ordinance. The roof is proposed with a pitched roof and architectural shingles,
once again to provide a residential character to the structures.
The exterior construction material proposed is a brick fagade. Additional
materials include materials as allowed per the Mid -town DOD or wood, stone,
tinted stucco and will be neutral tones. The maximum building height proposed
is 35 feet. The canopy is proposed 12.7 feet from the right of way on C Street.
The eastern side and rear yard setbacks, where abutting single-family zoned and
used property, are 22 feet and 30 feet respectively. The DOD allows for a side
yard setback of four (4) feet and a rear yard setback of twenty-five (25) feet. A
six-foot screening fence is proposed along these two property lines to provide the
required screening in this area.
A sidewalk has been provided along the eastern edge of the existing parking lot.
A sidewalk will be constructed on C Street in the right of way in front of the new
building. A right of way dedication of 30 feet from centerline will be provided to
the City along the frontage proposed for the new surgery center.
A single monument sign is proposed within the front landscaped area of the new
surgery center. The sign is proposed six feet in height and twenty-four square
feet in area.
The development is proposing landscaping for the new construction consistent
with landscaping required per the Mid -town DOD. A landscape strip of 12.9 feet
is proposed on C Street. The applicant is not proposing any modification or
addition of landscaping within the existing parking lot area.
The site contains a number of trees greater than 14 inches in diameter as
measured by the ordinance. The developer desires to save a number of these
trees but anticipates removal of three to four of the trees above 14 inches.
These trees are located within the building footprint and are impossible to save
and still allow the new construction.
Lighting will conform to the lighting standards as established in the Mid -town
DOD.
7
FILE NO.: Z-8445 (Cont.
Below list the requirements of the Mid -Town DOD and the applicant's proposal
related to each of the items:
Midtown Overlay District Applicant's Proposal
i
planned zoning district process all
be required for a new development,
redevelopment exceeding 50 percent of
the structure's current replacement
value based on its configuration at the
time of the DOD's adoption, and for
expansion of existing developments
exceeding 50 percent of the structure's
current square footage at the time of
the DOD's adoption. Routine repairs,
maintenance and interior alterations to
accommodate existing, expanding or
new tenants within the existing building
envelope shall not require compliance
with Chapter 36, Article 10 (Midtown
Design Overlay District). The proposed
planned zoning development shall be
reviewed to realize a development plan
that is consistent with the purpose and
intent of the Midtown Design Overlay
District.
For a new development or structure of
over 100.000 square feet (excluding
structured parking), a mix of uses must
be provided. This mix may occur either
under the same roof or in adjacent
structures as part of a common
development. In order to be considered
a mix, the new development must
either:
Devote the majority of its leasable
ground floor space to a secondary use
i.e. retail in a multi -story office building;
or
Devote ten percent of the gross
leasable area of a single building to the
secondary use i.e. residential on the
upper levels of a multi -story office, retail
or institutional building, or
A planned zoning development
being requested.
pplicable.
E:
FILE NO.: Z-8445 (Cont.
Devote fifteen percent of —the —gross
leasable area to a secondary use in a
separate building constructed and
occupied at the same time as the
primary structure i.e. a restaurant on a
pad adjacent to an office building.
he ---Mid - wn Design Overlay District
requires developments in excess of
200,000 square feet to contain a
residential component. The residential
may be in the same structure or a
separate structure, as long as the
separate structure is part of the overall
development and the overall
development is built simultaneously.
For any development constructed in
phases, a portion of the secondary
uses shall be included in the initial
phases.
Not Applicable.
Fagade treatment — for new The development is indicated with 40%
construction at least 60 percent of the of the front facade as glass -windows
ground floor level facing internal and entry features.
pedestrian public circulation areas or
streets shall be glass -windows, entry Variation from the DOD.
features or displays.
The primary fagade of a building shall
be oriented parallel with the street, or to
the principal vehicular or pedestrian
routes of travel whether public or
private.
The primary facade of the building is
oriented to the street.
Buildings shall maintain a distinction The building is a single story building.
between upper and lower levels; an
elevation greater than 18 feet in height
shall contain an architectural treatment,
which visually divides the structure into
stories.
Wall projections or recesses a minimum
of three feet deep and a minimum of 20
continuous feet not to extend over 20
percent of the fagade shall be required.
Arches, display windows, entry areas or
awnings shall exist along at least 60
percent of the facade.
No wall projections are proposed.
Arches, display windows, entry areas
or awnings are not proposed to exist
along at least 60 percent of the fagade.
9
FILE NO.: Z-8445 (Cont.
E.ntryway - Primary entrances shall be
oriented to the street or to the principal
vehicular or pedestrian routes of travel
within a development.
Buildings shall have clearly defined and
visible customer entrances featuring
elements such as overhangs, arcades,
arches, canopies, peaked roof forms,
display windows.
NII sides of buildings that face abutting
)ublic or private rights of way, except
alleys, shall feature at least one
,ustomer entrance.
levations - No elevation facing an
arterial or greater street shall be
crimarily used as a service entry or
)therwise be treated as the rear of the
Structures.
Vew construction wider than 100 linear
feet shall be visually massed so as to
creak the structure visually.
Rooflines shall be varied with changes
n height every 100 liner feet in building
ength. Parapets, mansard roofs, gable
roofs, high roofs, shall be used to
conceal flat roofs and roof top
equipment.
Exterior building materials and colors
shall be aesthetically pleasing and
compatible with materials and colors
used in neighboring developments.
Predominant exterior building materials
shall be of high quality materials; such
as but not limited to: brick, wood, stone,
tinted, stucco, EIFS (Exterior Insulation
Finish System) concreted masonry
units. Fagade colors - shall be low
reflectant, subtle, neutral or earth tone
with trim and accents brighter colors.
The primary entrance is p
fronting C Street.
The front entrance is clearly defined
and a canopy is proposed as a feature
to allow covered drop-off and pick-up
of patients.
Not applicable.
Not applicable.
The sides of the building exceed this
typical requirement; 108 feet. The
developer is not proposing any breaks
in the building or variation in the
roofline. A pitched roof is proposed
with architectural shingles to maintain
a residential character of the building.
The development is proposed to
compliment near by developments.
The primary construction materials will
be brick.
Predominant exterior building materials The predominate exterior building
shall not be smooth -faced concrete materials will not be concrete block,
10
FILE NO.: Z-8445 (Cont.
block, tilt -up concrete
prefabricated steel panels.
Projection
s
Awnings shall not project more than Live
(5) feet from the building facade and
have a minimum clearance of nine (9)
feet above pedestrian areas and
thirteen (13) feet above vehicular areas.
Balconies over the public right-of-way
shall have a minimum clearance of nine
(9) feet above the sidewalk. One (1)
inch of projection is permitted for each
additional inch of clearance above eight
(8) feet, provided that no such
projection shall exceed a distance of
four (4) feet. Balconies shall not be
supported with posts extending to the
sidewalk. Mounting heights for balcony
brackets shall conform to minimum
clearance standards.
applica
of applicable.
Building height — No building hereafter Not applicable.
erected or structural altered shall
exceed a height of 60 feet, except as
provided below. Structures may have a
greater height as follows, and these
bonuses may be cumulative:
Any structure that is certified by CATA Not applicable.
as provide a portion of the structure for
mass transit is entitled to add 15-feet.
Structures with a mix of uses with the Not applicable.
street -level primarily devoted to retail
uses and at lease 50 percent of these
uses having direct access to the street,
is entitled to add 25 feet to the
structure; alternately a development
with an integrated parking facility
substantially located within the footprint
of the primary structure, is entitled to
add 25 feet to the structure.
11
FILE NO.: Z-8445 (Cont.
Notwithstandin ithe foregoing, any The maximum building height
structure located north of West proposed is 35 feet.
Markham Street and east of University
shall be limited to a hei ht of 35 feet.
Building setbacks from property lines
and street rights of way shall be:
Front yard setbacks may be zero but
will not be more than 20-feet excepting
The canopy has a front setback of 12.7
feet.
in those cases where grade changes
make such setbacks impractical.
Side yard setbacks may be zero except The east side yard is adjacent to
where adjacent to lots containing single-family zoned and used property.
single-family detached structures. In The rear yard setback is proposed at
this case the side yard setback shall be 22 feet.
a setback of not less than four (4) feet.
Rear yard setback may be zero, except The rear yard is
where adjacent to lots containing family zoned and
single-family detached structures. In rear yard setback
this case the rear yard setback shall feet.
have a setback of not less than 25-feet.
Driveways. Sidewalks and Alleys — Not
Driveways and internal circulation
streets must have lanes at least ten feet
in width, but not more than 12 feet
excepting that width needed for bike
lanes or special pedestrian
accommodations.
Intersections of internal arives or
streets will be minimally controlled by
stop signs, and will feature special
crossway paving or treated surfaces.
Access driveways running parallel with
the street shall not create a four-way
intersection within 125 feet of the
ultimate curb line of the public street.
No more than one curb cut per block
face shall be permitted. Driveways and
parking lot entrances -exit shall be
combined and where appropriate
located in alleys.
Sidewalks and Pedestrian walkways —
AII driveways and internal streets shall
0
e
icable.
e.
adjacent to single -
used property. The
is proposed at 30
The site plan indicates a circular drive
to serve the surgery center. The drive
will be one way entering from the east
and exiting to the west.
of amlicable.
12
FILE NO.: Z-8445 (Cont.
have minimum five foot sidewalks on
both sides located away from the back
of curb.
All sidewalks fronting buildings with
ground floor retail shall be at least 10
feet in width.
Protected pedestrian walkways sha
provided through parking lots.
All developments shall include as part
of their site plan pedestrian linkages
through parking areas and to adjacent
buildings or developments.
Alleys -- shall not be more than 20-feet
wide unless needed for emergency
access. Where an alley runs along a
property line, it shall be screened from
the adjacent property by a permanent
wall of high quality materials compatible
with neighboring buildings.
All new utilities for developments within
the District shall be buried. All new
developments shall underground all
Utilities ❑nsite or within adjacent public
right of way wherever determined by
the utility agency to be feasible.
Trash enclosures shall be located in
alleys wherever available or in common
service areas for multiple
developments.
In all areas, service and waste removal
areas shall be screened and located
away from public outdoor spaces and
pedestrian. Dumpster screening shall
comply with Section 36-523.
M-
ot app
e.
applicable.
All utilizes on the site will be
underground. The existing overhead
utilities will not be placed underground
with this development.
Not applicable. There is no dumpster
located on this site.
Parking facilities — wherever feasible, Not applicable.
multilevel parking structures shall be
encouraged. Surface parking shall be
limited to the side and rear of
structures, unless grouped in quantities
13
FILE NO.: Z-8445 (Cont.
of 50 spaces or less separated by a
landscaping strip no less than the
perimeter landscape strip as required
for the property by Chapter 15 of the
code or a structure from other vehicular
areas and having no more than one
vehicular connection to another surface
parking area. Surface parking areas
should be broken up or distributed
around large structures so as to shorten
the distance to other buildings and
public sidewalks. For corner lots,
parking is allowed along the side street
frontage.
Parking requirements within the District
shall be 50 percent of that required by
Article VII of Chapter 36. The
maximum allowed parking shall be the
minimum standard established in Article
VII of Chapter 36.
Shared parking. As an alternative to
subsection (f)(2) above, mixed -use
developments may utilize the shared
parking methodologies developed by
the Urban Land Institute and published
in Shared Parking (Second Edition,
2005) by Mary S. Smith, et al. A project
may elect this means of determining the
total parking requirement by submitting
a parking demand analysis prepared by
a qualified parking or traffic consultant,
a licensed architect, city planner, or
urban planner or civil engineer.
On -street parking. On -street parking on
internal streets or circulation routes
shall be allowed and may count
towards the parking requirement. On -
street parking is permitted either
parallel, in areas in front of, or adjacent
to, retail or commercial entries. Angled
street (drive) parking shall not be
permitted on streets (drives) that
provide the development majority
access. Such parking may count
towards the overall project parking
requirements. No on -street parking
shall be allowed on University Avenue
or Markham Street.
Parking provided by an existing
parking lot located to the west.
Joe White- White-Daters and
Associates states - The surgery center
is being relocated from the existing
GAPA buildings to this new facility.
This will allow space for two more
physicians. As a civil engineer,
planner and parking demand analyst
the existing parking should be
adequate for the use. The surgeries
will be done in the moming with patient
visits in the afternoon. This will
eliminate the need for additional
parking. The parking on the south side
of C Street is also used for this facility.
Staff parks south of C Street and
patients and physicians park on the
north side of C Street.
Not applicable.
14
FILE NO.: Z-8445 Cont.
No parking shall be allowed in the front Not applicable.
yard setback area.
Parking garage design — Parking Not applicable.
facilities should be designed consistent
with the overall project design. Where
possible, other uses, residential or
commercial should be used to wrap or
otherwise block the view of a parking
garage.
Signage — Signage shall comply with
Article X except as follows — No off -site
advertising signs are permitted. No
pole mounted signs are permitted.
Monument signs are to identify the
development and be limited to 72
square feet in area and 6 feet in height
for developments greater than one
acre. For sites less than one acre
monument signs may be up to twenty-
four square feet in area and six feet in
height and must be located as a part of
the required landscape area of the
parking lot. Signage integrated into
free-standing vertical structures whose
design theme and materials are directly
related to the primary development may
be submitted for approval under the
PZD process if located along University
southerly of Lee. No single elevation or
face of such a structure shall be more
than 400 square feet.
No street buffer or landscaping is
required along streets classified less
than an arterial. When the structure is
not built to the property line,
landscaping is required in the area
between the building and property line
up to that required in Chapter 15 of the
Code.
A sign six feet in height and 24 square
feet in area is proposed to serve the
office use. Building signage will
comply with signage allowed in office
zones or a maximum of ten percent of
the fagade area.
Landscaping Tor me ouiiaing
construction will comply with the typical
ordinance standards. No new
landscaping is proposed for the
existing parking lot.
Land use buffers shall only be provided
Land use
where single-family and duplex use or
consistent
zoning is the abutting use. In those
standards o
cases where a land use buffer is
perimeters.
required, buffers shall be the same as
those for multi -family uses in Section
36-522(b)(1). In areas where terrain
variation is great or other features result
in the loss of privacy, alternative
buffers are provided
with the typical ordinance
n the northern and eastern
15
NO.: Z-8445 (Cont.
designs and massing shall be
considered.
Common use areas and plazas shall be Not applicable.
a minimum of 300 square feet for
30,000 square foot structures. For
each additional 5,000 square feet or
portion thereof, a minimum of an
additional 50 square feet of plaza area
is required.
Surface parking lots shall meet all No new parking areas are proposed.
current landscape requirements. The parking to serve the development
exists.
Street trees shall be a minimum of Street trees will be installed as
3-inch caliper and shall be 2 feet off the required.
back of curb, 30 feet on center. The
canopy shall be maintained with an
8 foot clearance. A four foot planter
strip shall be maintained.
Common use areas and plazas shall be
maintained by a common authority.
Attempts shall be made to maintain
vegetation, trees, bushes, in
undisturbed conditions to serve the
aesthetic, recreational and ecological
needs of the district. Trees planted in
these areas shall be a minimum of two
inches in caliper and ten feet in height.
Trees greater than 14 inches in
diameter, measured at 4 '/2 feet above
the ground, shall be protected from
removal and damages in future
development of the district. Any
development within 50 feet of such tree
shall be reviewed prior to development
to assure protective measures are
included and in place.
applicable.
Three to four trees greater tl
diameter will be removed to
building construction.
an14"in
allow the
Lighting shall conform to the design Lighting will conform to the standards
overlay district standards. The intent is established in the DOD.
to prevent light from commercial
developments from excessively
illuminating the property in question,
other properties or the night sky. Only
light fixtures, which are categorized as
full cut-off fixtures shall be permitted.
16
FILE NO.: Z-8445 (Cont.
The use of fully shielded floodlig
permitted but not encouraged.
are
The ordinance provides far the
following specific standards for lighting
intensity based upon the activities
performed involved. Values are
presented in allowable foot candles (fc)
maintained (measured horizontally) at
grade and are to be averaged
throughout the site to avoid hot spots,
i.e. areas of extreme light intensity
relative to the remainder of the site.
Pedestrian areas/sidewalks
Minimum 0.2 fc Maximum 1.0 fc
Building entries
Minimum 1.0 fc Maximum 10.0 fc
Street lighting
Minimum 0.2 fc Maximum 1.0 fc
Parking area
Minimum 2.0 fc Maximum 4.0 fc
Playgrounds
Maximum 5.0 fc
Sports grounds
Maximum 20.2 fc
Site perimeter
Maximum 0.5 fc
Lighting will conform to the standards
established in the DOD where
applicable.
Gas station canopies shall be Not app
illuminated at a maximum luminance of
thirty (30) fc and individual fixtures shall
be flush mounted or have the canopy
edge below the lowest light -emitting
point on the fixtures. All existing gas
station canopies that exceed this
standard shall be made compliant
within seven (7) years of the date of
adoption of this article.
Up lighting may be used to illuminate a I L
building, landscaping element or I e
architectural feature, provided the
liahtina design has a maximum 1
e.
Ling will conform to the standards
blished in the DOD.
17
FILE NO.: Z-8445 (Cont.
luminance of twelve (12) fc, measured
in a vertical plane. Down lighting is
preferred.
A lighting plan shall be suommea Tor
staff review and approval prior to
issuance of building permits. The plan
shall contain the following information:
An area lighting plan, drawn to scale,
indicating all structures, parking lots,
building entrances, vehicular and
pedestrian traffic areas, vegetation that
may interfere with lighting, and adjacent
land uses that may be adversely
impacted by the lighting. The plan shall
contain a layout of all proposed fixtures
by location, orientation, aiming
direction, mounting height and type.
The submission shall include, in
addition to proposed area lighting, all
other exterior lighting, e.g.,
architectural, building entrance,
landscape, flagpole, sign, etc.
A ten -foot by ten -foot luminance grid
(point -by -point) of maintained foot-
candles overlaid on the site plan plotted
out to 0.0 foot-candles, which
demonstrates compliance with light
intensity standards.
Property, if for any reason, that cannot
be developed without violating the
standards of this article shall be
reviewed through the planned zoning
district (PZD) section of the zoning
ordinance, with the intent to devise a
workable development plan which is
consistent with the purpose and intent
of the overlay standards.
Lighting will conform to the standards
established in the DOD.
The property is being considered as a
PZD.
Staff is supportive of the request. The site is located adjacent to office uses to
the west and the Mid -town Shopping Center to. the south. Southeast of this site,
at the intersection of C. and Pierce Streets, is an area currently zoned 0-3,
General Office District. Staff feels the office use allows for a stepping down of
intensity. The building is proposed constructed residential in character to allow a
transition from the office and commercial uses located along North University
Avenue to the single-family uses located east of this site. The building has been
It.]
FILE NO.: Z-8445 Cont.
placed to allow an increased buffer along the eastern perimeter to offer
protection to the single-family homes. The developers are not proposing the
addition of any new parking to serve the surgery center but are planning to utilize
an existing parking lot.
Although the site plan indicates the development inconsistent with the
development criteria established in the Mid -Town Design Overlay District, the site
is complying with a number of typical standards established. The primary
variations are to allow less than 60% of the front of the building to be glassed and
to remove trees in excess of 14-inches in diameter. Although staff feels these
are important considerations, staff does not feel these variations will significantly
impact the area if developed as proposed.
The developer have indicated a commitment to reduce the water run-off on the
properties located to the north by developing the site in such a manner that all
drainage from the proposed building and circular driveway are directed to
C Street. The developers have also agreed the flume at the north end of the
existing parking lot will be re -directed to the east and into a vegetated swale
running east -west along the north side of the proposed building. At the time of
development the developer will supply a new culvert to replace the existing
damaged culvert located along C Street. The City will install the culvert with City
work forces and equipment. When construction is ready to begin, the developer
will request the City clean the existing ditches along C Street and Pierce Street.
Staff feels the drainage as proposed will lessen the impact of the existing water
run-off on the properties located to the north.
The only issue remaining is the applicant's request to only include the east
one-half of an existing parking lot located west of the proposed surgery center in
the rezoning request. Staff feels the entire parking lot should be included in the
rezoning request. As noted above the rezoning of the parking area through this
PD-O request will recognize the existing use and allow continuity in the zoning
pattern. To staff's knowledge there are no other outstanding technical issues
associated with the request.
I. STAFF RECOMMENDATION -
Staff recommends approval of the request subject to compliance with the
comments and conditions as outlined in paragraphs D, E, F and as noted in
paragraph H of the above agenda staff report.
Staff recommends the entire parking lot and not just the east one-half of the
parking lot be included in the rezoning request.
Staff recommends the hours of service for the generator be limited to noon on
Wednesdays as proposed by the applicant.
PLANNING COMMISSION ACTION: (APRIL 30, 2009)
The applicant was present. There were no registered objectors present. Staff
presented the item with a recommendation of approval of the request subject to
compliance with the comments and conditions as outlined in paragraphs D, E, F and as
Wel
FILE NO.: Z-8445 (Cont.
noted in paragraph H of the agenda staff report. Staff presented a recommendation the
entire parking lot and not just the east one-half of the parking lot be included in the
rezoning request. Staff presented a recommendation the hours of service for the
generator be limited to noon on Wednesdays as proposed by the applicant.
There was no further discussion of the item. The chair entertained a motion for
placement of the item on the consent agenda for approval as recommended by staff.
The motion carried by a vote of 9 ayes, 0 noes and 2 absent.
Qi7
April 30, 2009
ITEM NO.: 5 FILE NO.: LU09-04-01
Name: Land Use Plan Amendment — Heights Hillcrest Planning District
Location: the north side of C Street, just east of University Avenue
Reacesi Multi Family to Office
Source: University Properties
PROPOSAL / REQUEST:
A Land Use Plan amendment in the Heights Hillcrest Planning District from Multi
Family to Office. Office represents services provided directly to consumers as
well as general offices which support more basic economic activities. The
applicant is proposing to remove the two houses on this property in order to build
a medical office.
EXISTING LAND USE AND ZONING:
The property is currently zoned R-3 Single Family District. Two single family
houses and an existing parking lot are located on this property. The property
immediately west of this site is zoned 0-3 Office and is occupied by several
different medical offices and their adjoining parking lots. North of this
amendment site is zoned R-3 Single Family District for single family residences,
which are occupied and in good repair. To the northeast is zoned Planned
Residential Development for a group of condominiums. South of the amendment
site is zoned Planned Commercial Development for the Midtown Mall shopping
center. To the southeast of this site is zoned R-5 Urban Residence District, but
the land is developed with three single family houses.
FUTURE LAND USE PLAN AND RECENT AMENDMENTS:
This area is currently shown as Multi Family on the Plan and has been shown as
this since 1999. It was amended as part of a large package in 1999 from Office
to Multi Family in an effort to keep the Office facing University and not C Street.
The Multi Family extends north and east of this site. The property to the west is
currently shown as Office. The property on the south side of C Street is shown
as Mixed Use and Multi Family.
On May 18, 2004, another change was approved for this area. The property
known as the Midtown Mall at the northeast corner of University and Markham
Street was amended from Office and Multi Family to Community Shopping for
the new shopping center.
April 30, 2009
SUBDIVISION
ITEM NO.: 5 (Cont.)_ FILE NO.: LU09-04-01
MASTER STREET PLAN:
C Street is shown as a Local Street. The primary function of a Local Street is
to provide access to adjacent properties. Local Streets which are abutted by
non-residential zoning/use or more intensive zoning than duplexes are
considered as "Commercial Streets". These streets have a design standard
the same as a Collector. These streets may require dedication of right-of-way
and may require street improvements for entrances and exits to the site.
BICYCLE PLAN:
There are no bike routes in the immediate vicinity.
PARKS:
The site is within eight blocks of a park area according the Master Parks Plan.
The War Memorial park complex is located to the southeast of this site.
HISTORIC ❑#STRICTS:
There are no city recognized historic districts that would be affected by this
amendment.
CITY RECOGNIZED NEIGHBORHOOD ACTION PLAN:
This area is covered by the Hillcrest Neighborhood Plan. Their Zoning and Land
Use goal states: "Adopt a plan of action to stop the degradation, to reverse its
course, and to recreate a neighborhood that is one again a pleasant place to
work and live. This includes no net loss of residential units by demolition or
conversion to other uses."
ANALYSIS:
This area has been shown as Multi Family on the Land Use Plan since 1999.
The western portion of this amendment site, which is currently a parking lot, was
amended from Office to Multi Family in 1999. Since that time, this area has seen
new development by way of the Midtown Mall just south of this application area.
The addition of the Midtown Mall to the area has brought much more traffic to
C Street with it being one of the main entrances into the shopping center.
Midtown Mall also changed the scale of the buildings in this vicinity. Where there
used to be single family residences there are now large scale commercial
buildings and a large parking lot. The massing of the buildings in the Midtown
2
April 30, 2009
SUBDIVISION
ITEM NO.: 5 (Cont.
FILE NO.: LU09-04-01
Mall are significantly larger than either the medical offices on University or of the
single family residences on C Street. The residences remaining on C Street are
now surrounded on the west with Office uses and the south with Commercial
uses. While some new condos have been built in this area, the majority of
C Street between University and Pierce Street has been changed to office or
commercial use. Medical offices have been in place just west of this application
area for many years. This application reflects an extension of these office uses.
Southeast of this location at the corner of Pierce and C Streets is vacant and
zoned 0-3, but it is still shown on the Future Land Use Plan as Multi Family.
There is not much undeveloped land in this vicinity that is shown as Office on the
Plan. University Avenue has had new offices built just north of this site and is
home to many medical offices. This application would bring this trend of medical
offices further east off of University onto C Street. This portion of C Street is in
transition and has a variety of uses. There is a condominium development at the
southwest corner of Lee Avenue and Pierce Street. It is a relatively new
development and appears to be fully occupied. Across University Avenue is a
high rise apartment complex that seems to be in good condition.
This area is also covered by the Midtown Design Overlay District. The purpose
of this DOD is to "create a quality vital atmosphere for businesses (commercial or
office) and residents. Buildings, parking areas, signage, landscaping and street
furnishings should all be designed to complement and encourage pedestrian use
both day and evening:' The ULI Redevelopment Plan for Midtown done in 2006
addresses redevelopment for the Midtown area and states: "Many basic retail and
service needs of the adjacent neighborhoods are underserved or entirely unmet.
Further, institutional users in Midtown —primarily hospitals and higher education --
need office space and other facilities for the professionals who want to be located
near them"
NEIGHBORHOOD COMMENTS:
Notices were sent to the following neighborhood association: Hillcrest. Staff has
received no comments from area residents.
STAFF RECOMMENDATIONS.
Approval.
PLANNING COMMISSION ACTION: (APRIL 30, 2009)
This item was placed on the consent agenda for approval. By a vote of 9 for
0 against the consent agenda was approved.
3
April 30, 2009
ITEM NO.: 5.1 FILE NO.: Z-8445
NAME: C Street Surgery Center Short -form PD-O
LOCATION: Located at 5910 C Street
DEVELOPER:
University Properties
409 North University Avenue
Little Rock, AR 72205
ENGINEERISURVEYOR:
White-Daters and Associates
24 Rahling Circle
Little Rock, AR 72223
AREA: 0.45 acres NUMBER OF LOTS: 1 Zoning Lot FT. NEW STREET: 0 LF
CURRENT ZONING: R-3, Single-family
ALLOWED USES
PROPOSED ZONING
PROPOSED USE
Single-family Residential
-m
Surgery Center
OVERLAY DISTRICT: Mid -Town Design Overlay District
VARIANCES/WAIVERS REQUESTED: None requested.
A. PROPOSAL/REQUEST:
The property is located near the intersection of C Street and University Avenue.
The property currently contains two occupied single-family residences. The
developers are seeking a rezoning of the property to allow the removal of the
homes and the construction of a new 8,780 square foot survey center. The
center will contain four (4) operating rooms and ten (10) prep and recovery
rooms. Two (2) doctors will operate from the facility.
The proposal includes an existing parking lot located immediately west of this
property. The doctors currently own this parking lot and intend to utilize this
parking area as the required parking for the surgery center. The parking lot
April 30, 2009
SUBDIVISION
ITEM NO.: 5.1 (Cont.
FILE NO.: Z-8445
contains 35 parking spaces. The applicant is proposing to only include one-half
of the parking lot with the application request resulting in 19 on -site parking
spaces. A parking lot located to the south of the site is proposed to provide
parking for staff. The off -site parking provided is 40 spaces.
B. EXISTING CONDITIONS:
There are occupied single-family homes located on the two lots proposed for
rezoning. The parking lot area located to the west of the two homes is currently
zoned R-3, Single-family and is also proposed for rezoning as a part of this
PD-O. To the north are single-family homes and to the east are two additional
homes. An area zoned PD-O located north of the parking lot has been
developed as parking to serve the doctors offices to the west. South of the site is
the Mid-towne Shopping Center and southeast are single-family homes and
multi -family housing. West of the site is a parking area serving the medical
offices fronting North University Avenue.
C. NEIGHBORHOOD COMMENTS:
As of this writing, staff has received several informational phone calls from area
residents. All property owners located within 200 feet of the site, all residents,
who could be identified, located within 300 feet of the site and the Hillcrest
Residents Association were notified of the public hearing.
D. ENGINEERING COMMENTS:
PUBLIC WORKS CONDITIONS
1. Due to the proposed use of the property, the Master Street Plan specifies
that C Street for the frontage of this property must meet commercial street
standards. Dedicate right-of-way to 30 feet from centerline.
2. With site development, provide the design of street conforming to the
Master Street Plan. Construct one-half street improvement to C Street
including
5-foot sidewalk with the planned development. The new back of curb
should be located 18 feet from the centerline of the street and match the
curb of the property to the west.
3. Repair or replace any curb and gutter or sidewalk that is damaged in the
public right-of-way prior to occupancy.
4. Plans of all work in right-of-way shall be submitted for approval prior to start
of work. Obtain barricade permit prior to doing any work in the right-of-way
from Traffic Engineering at (501) 379-1805 (Travis Herbner).
2
April 30, 2009
SUBDIVISION
ITEM NO.: 5.1 Cont. FILE NO.: Z-8445
E
5. A grading permit in accordance with Section 29-186 (c) and (d) will be
required prior to any land clearing or grading activities at the site. Other
than residential subdivisions, site grading and drainage plans must be
submitted and approved prior to the start of construction.
6. A Sketch Grading and Drainage Plan should be provided per Section
29-186 (e).
7. Measures to control an increase in stormwater drainage should be
implemented to not cause damage onto adjacent property from the
increased impervious area.
8. Provide the direction of flow and all stormwater flows (Q) entering and
leaving the property.
9. Street improvement plans shall include signage and striping. Traffic
Engineering must approve completed plans prior to construction.
10. The circle drive should be one way. Enter from the east driveway and exit
on the west driveway.
UTILITIES AND FIRE DEPARTMENT/COUNTY PLANNING:
Wastewater: Sewer available to this project.
Enter : Approved as submitted.
Center -Point Ener : No comment received.
AT & T: No comment received.
Central Arkansas Water: All Central Arkansas Water requirements in effect at
the time of request for water service must be met. A water main extension and
additional fire hydrant(s) will be required to provide adequate fire protection to
this facility. Due to the nature of this facility, installation of an approved reduced
pressure zone backflow preventer assembly (RPZ) is required on the domestic
water service. This assembly must be installed prior to the first point of use.
Central Arkansas Water (CAW) requires that upon installation of the RPZA,
successful tests of the assembly must be completed by a Certified Assembly
Tester licensed by the State of Arkansas and approved by CAW. The test results
must be sent to CAW's Cross Connection Section within ten days of installation
and annually thereafter. Contact the Cross Connection Section at 377-1226 if
you would like to discuss backflow prevention requirements for this project.
Fire Department: Additional fire hydrants maybe required. Contact Little Rock
Fire Department for additional information.
K,
April 30, 2009
SUBDIVISION
ITEM NO.: 5.1 (Cont.) FILE NO.: Z-8445
County Planning: No comment.
CATA: The site is not located on a dedicated CATA Bus Route.
F. ISSUES/TECHNICAL/DESIGN:
Plannina Division: This request is located in the Heights Hillcrest Planning
District. The Land Use Plan shows Multi Family for this property. The applicant
has applied for a rezoning from R-3, Single-family to Planned Development
Office to allow the construction of a medical office/surgery center.
A Land Use Plan amendment (LU09-04-01) a change from Multi Family to Office
is a separate item on this agenda.
Master Street Plan: C Street is shown as a Local Street. The primary function of
a Local Street is to provide access to adjacent properties. Local Streets which
are abutted by non-residential zoning/use or more intensive zoning than
duplexes are considered as "Commercial Street'. These streets have a design
standard the same as a Collector. These streets may require dedication of
right-of-way and may require street improvements for entrances and exits to the
site.
Bicycle Plan: There are no bike routes in the immediate vicinity.
Neighborhood Action Plan: This area is covered by the Hillcrest Neighborhood
Plan. Their Zoning and Land Use goal states: 'Adopt a plan of action to stop the
degradation, to reverse its course, and to recreate a neighborhood that is once
again a pleasant place to work and live. This includes no net loss of residential
units by demolition or conversion to other uses."
Landscape:
1. An eleven foot seven inch (117) foot land use buffer is required along the
northern perimeter of the site. A six foot nine inch (69) land use buffer is
required along the sites eastern perimeter. Easements cannot count toward
full -filling this requirement. Seventy percent (70%) of the buffer area is to
remain undisturbed.
2. The landscape ordinance requires a minimum of eight percent (8%) of the
paved areas be landscaped with interior islands of at least seven and one-half
(7 '/2) feet in width. Interior islands must be a minimum of one hundred and
fifty (150) square feet in area to qualify towards the minimum landscape
ordinance requirements.
Il
April 30, 2009
SUBDIVISION
ITEM NO.: 5.1 (Cont.
FILE NO.: Z-8445
3. Street trees are required per the Mid -town DOD. Street trees shall be a
minimum of three-inch caliper and shall be two (2) feet off the back of curb,
thirty (30) feet on center. The canopy shall be maintained with an eight -foot
clearance. A four -foot planter strip shall be maintained.
4. A street buffer of six feet nine inches (69) is required adjacent to the proposed
building construction site in accordance with the Landscape Ordinance.
5. The landscape ordinance requires a minimum landscape strip of three feet (3)
to be located between the parking lot and the building.
6. A six (6) foot high opaque screen, either a wooden fence with its face side
directed outward, a wall, or dense evergreen plantings, is required along the
northern and eastern perimeters of the site. Credit towards fulfilling this
requirement can be given for existing trees and undergrowth that satisfies this
year -around requirement.
G. SUBDIVISION COMMITTEE COMMENT: (April 9, 2009)
Mr. Joe White of White-Daters and Associates was present representing the
request. Staff presented an overview of the request stating there were additional
items necessary to complete the review process. Staff stated the site was
located within the Mid -Town Design Overlay District. Staff requested
development information related to the DOD standards to establish the areas of
compliance with the DOD. Staff noted any variation from the DOD was to be
approved by the Planning Commission and the Board of Directors through the
adoption of the ordinance and the site plan for the development. Staff noted the
parking lot located to the east of the surgery center was to also be included in the
overall review. Staff requested the legal description of the parking lot be added
to the site plan and survey.
Public Works comments were addressed. Staff stated there were drainage
concerns from the existing parking lot and the sheet flow of water onto the
adjacent property owners. Staff requested Mr. White provide the direction of flow
and all storm water flows entering and leaving the property. Staff also requested
Mr. White provide a sketch grading and drainage plan. Staff stated the circle
drive indicated on the site plan be a one-way drive. Staff stated the drive should
enter from the east and exit on the west.
Landscaping comments were addressed. Staff stated screening was required
along the northern and eastern perimeters of the site. Staff stated a small
amount of building landscaping would be required. Staff noted street trees would
be required per the Mid -Town DOD.
Staff stated the generator was shown on the north side of the building adjacent to
the single-family zoned and used property. Staff requested limits be placed on
5
April 30, 2009
SUBDIVISION
ITEM NO.: 5.1 (Cont) FILE NO.: Z-8445
the hours of testing the generator similar to the limits placed on the dumpster
hours of service.
Staff noted comments from the other reporting departments and agencies
suggesting the applicant contact them individually for additional clarification.
There was no further discussion of the item. The Committee then forwarded the
item to the full Commission for final action.
H. ANALYSIS:
The applicant submitted a revised cover letter and site plan to staff addressing a
number of the issues raised at the April 9, 2009, Subdivision Committee meeting.
The revise plan indicates the east one-half of the parking lot located on the west
side of the proposed surgery center to be included in the proposed rezoning
request. Staff feels the entire parking lot should be included in the rezoning
request. The drive is a two-way drive and it will be difficult to separate patient
and staff parking. The parking lot is zoned R-3, Single-family and was approved
by the Board of Adjustment for construction of the parking lot a number of years
ago. The parking lot was not constructed until three years ago. The rezoning of
the entire parking lot along with this request will bring continuity to the zoning of
this area.
The applicant has provided a sketch grading and drainage plan. The plan
indicates predevelopment and post -development water flows. On the north side
of the property the Q25 Undeveloped is 2.9 cfs and the Q25 Developed is 1.9 cfs.
On C Street the Q25 Undeveloped is 1.2 cfs and the Q25 Developed is 3.0 cfs.
The developer has indicated all roof drains will be routed to C Street. The site
plan indicates the flume located on the western parking lot will be redirected to
allow the water to flow eastward and be swaled in order to disperse the water in
an even manner rather than a single point of discharge.
The drive in front of the building is indicated as a one-way drive as requested by
Public Works staff. The drive width will allow for two lanes to allow passing and
not require automobiles to stack in the driveway.
The revised site plan has not relocated the generator from the north face of the
building. The hours of generator service have been limited to daylight hours and
most likely be on Wednesday at noon. Staff feels the limits of generator service
should be limited to the hours indicated by the applicant.
The development is proposed with construction of a new surgery center
containing 8,870 square feet. The total landscaped area proposed is
12,225 square feet or 38.2 percent of the site. The paved area proposed is
11,035 square feet or 34.4 percent of the site. Two doctors will operate from the
0
April 30, 2009
SUBDIVISION
ITEM NO.: 5.1 (Cont.
FILE NO.: Z-8445
facility. There are two operating rooms proposed and ten prep and recovery
rooms. The applicant has indicated the east one-half of an existing parking lot
containing 19 parking spaces to serve the surgery center. The hours of operation
are from 7 am to 5 pm daily.
The property being considered for rezoning is located within the Mid -town Design
Overlay District. The ordinance has various development standards related to
building setbacks, heights, construction materials and building appearances.
The fagade treatment for new construction requires a minimum of 60 percent of
the ground floor level facing internal pedestrian public circulation areas or streets
be glass -windows, entry features or displays. The applicant has indicated
40 percent of the front of the building will be glassed. The intent of the developer
is to construct an office building with a residential flair. According to the
developers to meet this goal it is difficult to provide 60 percent of the fagade with
glass features. The primary fagade of the building will be oriented parallel to the
street. The building is proposed as a singe story building. No wall projections or
recesses are proposed on the structure along the sides or rear wall. The front of
the building will have a projection extending to a covered canopy to be used for
patient drop-off and pick-up. The sides of the building is proposed 108 liner feet.
The building is not proposed with breaks in the building to visually break the
mass since the structure is so close to the 100-foot standard established by the
ordinance. The roof is proposed with a pitched roof and architectural shingles,
once again to provide a residential character to the structures.
The exterior construction material proposed is a brick fagade. Additional
materials include materials as allowed per the Mid -town DOD or wood, stone,
tinted stucco and will be neutral tones. The maximum building height proposed
is 35 feet. The canopy is proposed 12.7 feet from the right of way on C Street.
The eastern side and rear yard setbacks, where abutting single-family zoned and
used property, are 22 feet and 30 feet respectively. The DOD allows for a side
yard setback of four (4) feet and a rear yard setback of twenty-five (25) feet. A
six-foot screening fence is proposed along these two property lines to provide the
required screening in this area.
A sidewalk has been provided along the eastern edge of the existing parking lot.
A sidewalk will be constructed on C Street in the right of way in front of the new
building. A right of way dedication of 30 feet from centerline will be provided to
the City along the frontage proposed for the new surgery center.
A single monument sign is proposed within the front landscaped area of the new
surgery center. The sign is proposed six feet in height and twenty-four square
feet in area.
7
April 30, 2009
SUBDIVISION
ITEM NO.: 5.1 Cont. FILE NO.: Z-8445
The development is proposing landscaping for the new construction consistent
with landscaping required per the Mid -town DOD. A landscape strip of 12.9 feet
is proposed on C Street. The applicant is not proposing any modification or
addition of landscaping within the existing parking lot area.
The site contains a number of trees greater than 14 inches in diameter as
measured by the ordinance. The developer desires to save a number of these
trees but anticipates removal of three to four of the trees above 14 inches.
These trees are located within the building footprint and are impossible to save
and still allow the new construction.
Lighting will conform to the lighting standards as established in the Mid -town
DOD.
Below list the requirements of the Mid -Town DOD and the applicants proposal
related to each of the items:
Midtown Overlay District Applicant's Proposal
A planned zoning district process snail
be required for a new development,
redevelopment exceeding 50 percent of
the structure's current replacement
value based on its configuration at the
time of the DOD's adoption, and for
expansion of existing developments
exceeding 50 percent of the structure's
current square footage at the time of
the DOD's adoption. Routine repairs,
maintenance and interior alterations to
accommodate existing, expanding or
new tenants within the existing building
envelope shall not require compliance
with Chapter 36, Article 10 (Midtown
Design Overlay District). The proposed
planned zoning development shall be
reviewed to realize a development plan
that is consistent with the purpose and
intent of the Midtown Design Overlay
District.
A planned zoning development is
being requested.
For a new development or structure of Not Applicable.
over 100,000 square feet (excluding
structured parking), a mix of uses must
be provided. This mix may occur either
0
April 30, 2009
SUBDIVISION
ITEM NO.: 5.1 (Cont.)
under the same roof or in adjacent
structures as part of a common
development. In order to be considered
a mix, the new development must
either:
Devote the majority of its leasable
ground floor space to a secondary use
i.e. retail in a multi -story office building;
or
Devote ten percent of the gross
leasable area of a single building to the
secondary use i.e. residential on the
upper levels of a multi -story office, retail
or institutional building; or
Devote fifteen percent of the gross
leasable area to a secondary use in a
separate building constructed and
occupied at the same time as the
primary structure i.e. a restaurant on a
pad adjacent to an office building.
The Midtown Design Overlay District
requires developments in excess of
200,000 square feet to contain a
residential component. The residential
may be in the same structure or a
separate structure, as long as the
separate structure is part of the overall
development and the overall
development is built simultaneously.
For any development constructed in
phases, a portion of the secondary
uses shall be included in the initial
phases.
Facade treatment —tor new construction
at least 60 percent of the ground floor
level facing internal pedestrian public
circulation areas or streets shall be
glass -windows, entry features or
displays.
FILE NO.: Z-8445
The development is
of the front facade
and entry features.
ndicated with 40%
as glass -windows
Variation from the DOD.
01
April 30, 2009
SUBDIVISION
ITEM NO.: 5.1 (Co
The primary facade of a building shall
be oriented parallel with the street, or to
the principal vehicular or pedestrian
routes of travel whether public or
private.
Buildings shall maintain a distinction
between upper and lower levels; an
elevation greater than 18 feet in height
shall contain an architectural treatment,
which visually divides the structure into
stories.
Wall projections or recesses a minimum
of three feet deep and a minimum of 20
continuous feet not to extend over 20
percent of the facade shall be required.
Arches, display windows, entry areas or
awnings shall exist along at least 60
percent of the facade.
Entryway — Primary entrances shall be
oriented to the street or to the principal
vehicular or pedestrian routes of travel
within a development.
Buildings shall have clearly defined and
visible customer entrances featuring
elements such as overhangs, arcades,
arches, canopies, peaked roof forms,
display windows.
All sides of buildings that face abutting
public or private rights of way, except
alleys, shall feature at least one
customer entrance.
Elevations - No elevation facing an
arterial or greater street shall be
primarily used as a service entry or
otherwise be treated as the rear of the
structures.
FILE NO.: Z-8445
The primary facade of the building is
oriented to the street.
The building is a single story building.
No wall projections are proposed.
Arches, display windows, entry areas
or awnings are not proposed to exist
along at least 60 percent of the facade.
I he primary ei
fronting C Street.
nce is proposed
The front entrance is clearly defined
and a canopy is proposed as a feature
to allow covered drop-off and pick-up
of patients.
Not applicable.
Not applicable.
New construction wider than 100 linear The sides of the building exceed this
feet shall be visually massed so as to typical requirement; 108 feet. The
break the structure visually. developer is not proposing any breaks
in the building or variation in the
roofline. A pitched roof is proposed
`n
April 30, 2009
SUBDIVISION
ITEM NO.: 5.1(Cont.)FILE NO.: Z-8445
Rooflines shall be varied with changes
in height every 100 liner feet in building
length. Parapets, mansard roofs, gable
roofs, high roofs, shall be used to
conceal flat roofs and roof top
equipment.
Exterior building materials and colors
shall be aesthetically pleasing and
compatible with materials and colors
used in neighboring developments.
Predominant exterior building materials
shall be of high quality materials; such
as but not limited to: brick, wood, stone,
tinted, stucco, EIFS (Exterior Insulation
Finish System) concreted masonry
units. Facade colors — shall be low
reflectant, subtle, neutral or earth tone
with trim and accents brighter colors.
Predominant exterior building materials
shall not be smooth -faced concrete
block, tilt -up concrete panels or
prefabricated steel panels.
Projections (all requirements for a
franchise remain in place). Objects
shall not project from the building
facade over the public right of way
except for awnings, signs, and
balconies.
with architectural shingles to maintain
a residential character of the building.
The development is propo5uu
compliment near by developments.
to
The primary construction materials will
be brick.
The predominate e
materials will not be
tilt -up concrete panels
steel panels.
t applicable.
Awnings shall not project more than five Not a
(5) feet from the building facade and
have a minimum clearance of nine (9)
feet above pedestrian areas and
thirteen (13) feet above vehicular areas.
Baiconies over the public right-of-way Not app
shall have a minimum clearance of nine
(9) feet above the sidewalk. One (1)
inch of projection is permitted for each
additional inch of clearance above eight
(8) feet, provided that no such
projection shall exceed a distance of
four (4) feet. Balconies shall not be
suDDorted with posts extending to the
e.
;terior building
concrete block,
or prefabricated
11
April 30, 2009
SUBDIVISION
ITEM NO.: 5.1 (Cont.) FILE NO.: Z-8445
sidewalk. Mounting heights for balcony
brackets shall conform to minimum
clearance standards.
Building height — No building hereafter
erected or structural altered shall
exceed a height of 50 feet, except as
provided below. Structures may have a
greater height as follows, and these
bonuses may be cumulative:
Any structure that is certified by CATA
as provide a portion of the structure for
mass transit is entitled to add 15-feet.
Structures with a mix of uses with the
street -level primarily devoted to retail
uses and at lease 50 percent of these
uses having direct access to the street,
is entitled to add 25 feet to the
structure; alternately a development
with an integrated parking facility
substantially located within the footprint
of the primary structure, is entitled to
add 25 feet to the structure.
Notwithstanding the foregoing, any
structure located north of West
Markham Street and east of University
shall be limited to a height of 35 feet.
Building setbacks trom property lines
and street rights of way shall be:
of appiicable.
Not applicable.
Not applicable.
The maximum
proposed is 35 feel
Front yard setbacks may be zero but The canopy has a front setback of 12.7
will not be more than 20-feet excepting , feet.
in those cases where grade changes
make such setbacks impractical.
Side yard setbacks may be zero except The east side yarn 1
where adjacent to lots containing single-family zoned and
single-family detached structures. In The rear yard setback
this case the side yard setback shall be 22 feet.
a setback of not less than four (4) feet.
s adjacent to
used property.
is proposed at
Rear yard setback may be zero, except The rear yard is adjacent to single -
where adjacent to lots containin famil zoned and used property. The
12
April 30, 2009
SUBDIVISION
TEM NO.. 5.1 (Cont.
single-family detached structures. in
this case the rear yard setback shall
have a setback of not less than 25-feet.
Driveways, Sidewalks and Alleys —
Driveways and internal circulation
streets must have lanes at least ten feet
in width, but not more than 12 feet
excepting that width needed for bike
lanes or special pedestrian
accommodations.
Intersections of internal drives or
streets will be minimally controlled by
stop signs, and will feature special
crossway paving or treated surfaces.
Access driveways running parallel with
the street shall not create a four-way
intersection within 125 feet of the
ultimate curb line of the public street.
No more than one curb cut per hlocK
face shall be permitted. Driveways and
parking lot entrances -exit shall be
combined and where appropriate
located in alleys.
Sidewalks and Pedestrian walkways —
AII driveways and internal streets shall
have minimum five foot sidewalks on
both sides located away from the back
of curb.
All sidewalks fronting buildings wan
ground floor retail shall be at least 10
feet in width.
Protected pedestrian walkways shall be
provided through parking lots.
All developments shall include as part
of their site plan pedestrian linkages
through parking areas and to adjacent
buildings or developments.
FILE NO.: Z-8445
Fear yard setback is proposed at
feet.
Not applicable.
applica
Not app icame.
The site plan indicates a circular drive
to serve the surgery center. The drive
will be one way entering from the east
and exiting to the west.
applica
Not applicable.
applica
13
April 30, 2009
SUBDIVISION
ITEM NO.: 5.1 Cont. FILE NO.: Z-8445
Alleys —shall not be more than 20-feet Notapp
wide unless needed for emergency
access. Where an alley runs along a
property line, it shall be screened from
the adjacent property by a permanent
wall of high quality materials compatible
with neighboring buildings.
All new utilities for developments within
the District shall be buried. All new
developments shall underground all
utilities onsite or within adjacent public
right of way wherever determined by
the utility agency to be feasible.
FTr—ashenclosur—esshall be located in
alleys wherever available or in common
service areas for multiple
developments.
In all areas, service and waste removal
areas shall be screened and located
away from public outdoor spaces and
pedestrian. Dumpster screening shall
comply with Section 36-523.
Narking taclnties -- wnerever reasime,
multilevel parking structures shall be
encouraged. Surface parking shall be
limited to the side and rear of
structures, unless grouped in quantities
of 50 spaces or less separated by a
landscaping strip no less than the
perimeter landscape strip as required
for the property by Chapter 15 of the
code or a structure from other vehicular
areas and having no more than one
vehicular connection to another surface
parking area. Surface parking areas
should be broken up or distributed
around large structures so as to shorten
the distance to other buildings and
public sidewalks. For corner lots,
r)arkina is allowed alonq the side street
All utilizes on the site will be
underground. The existing overhead
utilities will not be placed underground
with this development.
Not applicable. There is no dumpster
located on this site.
applica
14
April 30, 2009
SUBDIVISION
ITEM NO.: 5.1 Cont. FILE NO.: Z-8445
Parking requirements within the District
shall be 50 percent of that required by
Article VII of Chapter 36. The
maximum allowed parking shall be the
minimum standard established in Article
VI I of Chapter 36.
Shared parking. As an alternative to
subsection (f)(2) above, mixed -use
developments may utilize the shared
parking methodologies developed by
the Urban Land Institute and published
in Shared Parking (Second Edition,
2005) by Mary S. Smith, et al. A project
may elect this means of determining the
total parking requirement by submitting
a parking demand analysis prepared by
a qualified parking or traffic consultant,
a licensed architect, city planner, or
urban planner or civil engineer.
On -street parking. On -street parking on
internal streets or circulation routes
shall be allowed and may count
towards the parking requirement. On -
street parking is permitted either
parallel, in areas in front of, or adjacent
to, retail or commercial entries. Angled
street (drive) parking shall not be
permitted on streets (drives) that
provide the development majority
access. Such parking may count
towards the overall project parking
requirements. No on -street parking
shall be allowed on University Avenue
or Markham Street.
No parking shall be allowed in the front
yard setback area.
Parking provided by an existing
parking lot located to the west.
Joe White- White-uaters ana
Associates states - The surgery center
is being relocated from the existing
GAPA buildings to this new facility.
This will allow space for two more
physicians. As a civil engineer,
planner and parking demand analyst
the existing parking should be
adequate for the use. The surgeries
will be done in the morning with patient
visits in the afternoon. This will
eliminate the need for additional
parking. The parking on the south side
of C Street is also used for this facility.
Staff parks south of C Street and
patients and physicians park on the
north side of C Street.
appiic
applicable.
Parking garage design — Parking Not applicable.
facilities should be designed consistent
with the overall project design. Where
possible, other uses, residential or
15
April 30, 2009
SUBDIVISION
ITEM NO.: 5.1 (Cont.
commercial should be used to wrap or
otherwise block the view of a parking
garage.
Signage — Signage shall comply with
Article X except as follows — No off -site
advertising signs are permitted. No
pole mounted signs are permitted.
Monument signs are to identify the
development and be limited to 72
square feet in area and 6 feet in height
for developments greater than one
acre. For sites less than one acre
monument signs may be up to twenty-
four square feet in area and six feet in
height and must be located as a part of
the required landscape area of the
parking lot. Signage integrated into
free-standing vertical structures whose
design theme and materials are directly
related to the primary development may
be submitted for approval under the
PZD process if located along University
southerly of Lee. No single elevation or
face of such a structure shall be more
than 400 square feet.
No street [Duffer or landscaping is
required along streets classified less
than an arterial. When the structure is
not built to the property line,
landscaping is required in the area
between the building and property line
up to that required in Chapter 15 of the
Code.
Land use burners snap only ue pruv3ut-u
where single-family and duplex use or
zoning is the abutting use. In those
cases where a land use buffer is
required, buffers shall be the same as
those for multi -family uses in Section
36-522(b)(1 ). In areas where terrain
variation is great or other features result
in the loss of privacy, alternative
designs and massing shall be
considered.
FILE NO.: Z-8445
A sign six feet in neignt ana z4 square
feet in area is proposed to serve the
office use. Building signage will
comply with signage allowed in office
zones or a maximum of ten percent of
the facade area.
Landscaping for the building
construction will comply with the typical
ordinance standards. No new
landscaping is proposed for the
existing parking lot.
Land use buffers are provided
consistent with the typical ordinance
standards on the northern and eastern
perimeters.
16
April 30, 2009
SUBDIVISION
ITEM NO.: 5.1 Cont. FILE NO.: Z-8445
Common use areas and plazas shall be
Not applicable.
a minimum of 300 square feet for
30,000 square foot structures. For
each additional 5,000 square feet or
portion thereof, a minimum of an
additional 50 square feet of plaza area
is required.
Surface parking lots shall meet all
No new parking areas are proposed.
current landscape requirements.
The parking to serve the development
exists.
Street trees shall be a minimum of
3-inch caliper and shall be 2 feet off the
back of curb, 30 feet on center. The
canopy shall be maintained with an
8 foot clearance. A four foot planter
strip shall be maintained.
Common use areas and plazas shall be
maintained by a common authority.
Attempts shall be made to maintain
vegetation, trees, bushes, in
undisturbed conditions to serve the
aesthetic, recreational and ecological
needs of the district. Trees planted in
these areas shall be a minimum of two
inches in caliper and ten feet in height.
Trees greater than 14 inches in
diameter, measured at 4 '/2 feet above
the ground, shall be protected from
removal and damages in future
development of the district. Any
development within 50 feet of such tree
shall be reviewed prior to development
to assure protective measures are
included and in place.
Street trees will be installed as
required.
appiicaoie.
Three to four trees greater than 14' in
diameter will be removed to allow the
building construction.
Lighting shall conform to the design Lighting will conform to the standards
overlay district standards. The intent is established in the DOD.
to prevent light from commercial
developments from excessively
illuminating the property in question,
other properties or the night sky. Only
light fixtures, which are categorized as
full cut-off fixtures shall be permitted.
17
April 30, 2009
SUBDIVISION
ITEM NO.: 5.1 Cont. FILE NO.: Z-8445
The use of fully shielded tloodlignts are
permitted but not encouraged.
The ordinance provides for the
following specific standards for lighting
intensity based upon the activities
performed involved. Values are
presented in allowable foot candles (fc)
maintained (measured horizontally) at
grade and are to be averaged
throughout the site to avoid hot spots,
i.e. areas of extreme light intensity
relative to the remainder of the site:
Pedestrian areas/sidewalks
Minimum 0.2 fc Maximum 1.0 fc
Building entries
Minimum 1.0 fc Maximum 10.0 fc
Street lighting
Minimum 0.2 fc Maximum 1.0 fc
Parking area
Minimum 2.0 fc Maximum 4.0 fc
Playgrounds
Maximum 5.0 fc
Sports grounds
Maximum 20.2 fc
Site perimeter
Maximum 0.5 fc
Gas station canopies shall oe
illuminated at a maximum luminance of
thirty (30) fc and individual fixtures shall
be flush mounted or have the canopy
edge below the lowest light -emitting
point on the fixtures. All existing gas
station canopies that exceed this
standard shall be made compliant
within seven (7) years of the date of
adoption of this article.
lighting will conform to the standards
established in the DOD where
applicable.
of applicable.
in
April 30, 2009
SUBDIVISION
ITEM NO.: 5.1 (Cont.
Up lighting may be used to illuminate a
building, landscaping element or
architectural feature, provided the
lighting design has a maximum
luminance of twelve (12) fc, measured
in a vertical plane. Down lighting is
preferred.
A lighting plan snail pe sucmmea Tor
staff review and approval prior to
issuance of building permits. The plan
shall contain the following information:
An area lighting plan, drawn to scale,
indicating all structures, parking lots,
building entrances, vehicular and
pedestrian traffic areas, vegetation that
may interfere with lighting, and adjacent
land uses that may be adversely
impacted by the lighting. The plan shall
contain a layout of all proposed fixtures
by location, orientation, aiming
direction, mounting height and type.
The submission shall include, in
addition to proposed area lighting, all
other exterior lighting, e.g.,
architectural, building entrance,
landscape, flagpole, sign, etc.
A ten -foot by ten -foot luminance grid
(point -by -point) of maintained foot-
candles overlaid on the site plan plotted
out to 0.0 foot-candles, which
demonstrates compliance with light
intensity standards.
Property, if for any reason, that cannot
be developed without violating the
standards of this article shall be
reviewed through the planned zoning
district (PZD) section of the zoning
ordinance, with the intent to devise a
workable development plan which is
consistent with the purpose and intent
of the overlay standards.
FILE NO.: Z-8445
hting will conform to the stanaaras
ablished in the DOD.
Lighting will conform to the standards
established in the DOD.
The property is being considered as a
PZD.
19
April 30, 2009
SUBDIVISION
ITEM NO.: 5.1 (Cont.
FILE NO.: Z-8445
Staff is supportive of the request. The site is located adjacent to office uses to
the west and the Mid -town Shopping Center to the south. Southeast of this site,
at the intersection of C and Pierce Streets, is an area currently zoned 0-3,
General Office District. Staff feels the office use allows for a stepping down of
intensity. The building is proposed constructed residential in character to allow a
transition from the office and commercial uses located along North University
Avenue to the single-family uses located east of this site. The building has been
placed to allow an increased buffer along the eastern perimeter to offer
protection to the single-family homes. The developers are not proposing the
addition of any new parking to serve the surgery center but are planning to utilize
an existing parking lot.
Although the site plan indicates the development inconsistent with the
development criteria established in the Mid -Town Design Overlay District, the site
is complying with a number of typical standards established. The primary
variations are to allow less than 60% of the front of the building to be glassed and
to remove trees in excess of 14-inches in diameter. Although staff feels these
are important considerations, staff does not feel these variations will significantly
impact the area if developed as proposed.
The developer have indicated a commitment to reduce the water run-off on the
properties located to the north by developing the site in such a manner that all
drainage from the proposed building and circular driveway are directed to
C Street. The developers have also agreed the flume at the north end of the
existing parking lot will be re -directed to the east and into a vegetated Swale
running east -west along the north side of the proposed building. At the time of
development the developer will supply a new culvert to replace the existing
damaged culvert located along C Street. The City will install the culvert with City
work forces and equipment. When construction is ready to begin, the developer
will request the City clean the existing ditches along C Street and Pierce Street.
Staff feels the drainage as proposed will lessen the impact of the existing water
run-off on the properties located to the north.
The only issue remaining is the applicants request to only include the east
one-half of an existing parking lot located west of the proposed surgery center in
the rezoning request. Staff feels the entire parking lot should be included in the
rezoning request. As noted above the rezoning of the parking area through this
PD-O request will recognize the existing use and allow continuity in the zoning
pattern. To staffs knowledge there are no other outstanding technical issues
associated with the request.
1. STAFF RECOMMENDATION:
Staff recommends approval of the request subject to compliance with the
comments and conditions as outlined in paragraphs D, E, F and as noted in
paragraph H of the above agenda staff report.
Staff recommends the entire parking lot and not just the east one-half of the
parking lot be included in the rezoning request.
20
April 30, 2009
SUBDIVISION
ITEM NO.: 5.1 (Cont.
FILE NO.: Z
Staff recommends the entire parking lot and not just the east one-half of the
parking lot be included in the rezoning request.
Staff recommends the hours of service for the generator be limited to noon on
Wednesdays as proposed by the applicant.
PLANNING COMMISSION ACTION: (APRIL 30, 2009)
The applicant was present. There were no registered objectors present. Staff
presented the item with a recommendation of approval of the request subject to
compliance with the comments and conditions as outlined in paragraphs D, E, F and as
noted in paragraph H of the agenda staff report. Staff presented a recommendation the
entire parking lot and not just the east one-half of the parking lot be included in the
rezoning request. Staff presented a recommendation the hours of service for the
generator be limited to noon on Wednesdays as proposed by the applicant.
There was no further discussion of the item. The chair entertained a motion for
placement of the item on the consent agenda for approval as recommended by staff.
The motion carried by a vote of 9 ayes, 0 noes and 2 absent.
21
ITEM NO.: 5.1. Z-8445
NAME: C Street Surgery Center Short -form PD-O
LOCATION: located at 5910 C Street
Planning Staff Comments:
1. Provide notification of all property owners located within 200 feet of the site,
complete with the certified abstract list, notice form with affidavit executed and proof
of mailing. The notice must be mailed no later than April 15, 2009. The Office of
Planning and Development must receive the proof of notice no later than April 24,
2009.
2. Does University Properties currently own the area proposed for rezoning? If not
provide a copy of the offer and acceptance or affidavits from the current owners.
3. The Site Plan indicates the hours of dumpster service from 7 am to 6 pm.
4. Provide the dimension of the landscape strip along the western parking area.
5. Provide the building setback dimension for the canopy along C Street.
6. Provide the location of any ground mounted signage, the total sign height and total
sign area. Provide details of proposed building signage.
7. Provide details of any proposed fencing including construction material and total
height.
8. Provide the percentage of landscape area and paved area in the general notes
section of the site plan.
9. The parking lot proposed as parking for the building should be included in the
request for rezoning. Provide the legal description to include this area.
10. Is the building proposed as a single story or multi -story building?
11. Provide the additional information noted below to allow review of the Mid -town DOD
requirements.
Mid -Town DOD Reauirements:
The site is located within the Mid -Town DOD area. Information for review of the Overlay
requirements is listed below:
1. For new construction, at least sixty (60) percent of the ground floor level facing
internal pedestrian public circulation areas or streets shall be glass -windows, entry
features, or displays. The primary facade of a building shall be oriented parallel
with the street, or to the principal vehicular or pedestrian routes of travel whether
public or private. Buildings shall maintain a distinction between upper and lower
levels; any elevation greater than eighteen (18) feet in height shall contain an
architectural treatment, which visually divides the structure into "stories". Wall
projections or recesses a minimum of three (3) feet depth and a minimum of twenty
(20) contiguous feet not to extend over twenty (20) percent of the facade shall be
required. Arcades, display windows, entry areas or awnings shall exist along at least
sixty (60) percent of the facade. Provide details of the proposed building
Item # 5.1.
construction. Will the building contain a minimum of 60% glass -windows,
entry features or displays? Will arcades, display windows, entry areas or
awnings exist along at least 60% of the facade?
2. Primary entrances shall be oriented to the street or to the principal vehicular or
pedestrian routes of travel within a development. Buildings shall have clearly
defined and visible customer entrances featuring elements such as overhangs,
arcades, arches, canopies, peaked roof forms, display windows. All sides of building
that face abutting public or private rights -of -way, except alleys, shall feature at least
one customer entrance. The development is proposed with a canopy and drive
on the street side of the building.
3. No elevation facing an arterial or greater street shall be primarily used as a service
entry or otherwise be treated as the rear of the structure. New construction wider
than the one hundred (100) linear feet shall be visually massed so as to break the
structure visually. Rooflines shall be varied with a change in height every one
hundred (100) linear feet in building length. Parapets, mansard roofs, gable roofs,
high roofs shall be used to conceal flat roofs and roof top equipment. Exterior
building materials and colors shall be aesthetically pleasing and compatible with
materials and colors used in neighboring developments. Predominant exterior
building materials shall be of high quality materials; such as, but not limited to: brick,
wood, stone, tinted, stucco, EIFS (exterior insulation finish system) concreted
masonry units. Facade colors shall be low reflectant, subtle, neutral or earth tone
with trim and accents brighter colors. Predominant exterior building materials shall
not be smooth -faced concrete block, tilt -up concrete panels or prefabricated steel
panels. Provide details of proposed building construction materials.
4. Objects shall not project from the building facade over the public right of way except
for awnings, signs, and balconies. Awnings shall not project more than five (5) feet
from the building facade and have a minimum clearance of nine (9) feet above
pedestrian areas and thirteen (13) feet above vehicular areas. Balconies over the
public right-of-way shall have a minimum clearance of nine (9) feet above the
sidewalk. One (1) inch of projection is permitted for each additional inch of clearance
above eight (8) feet, provided that no such projection shall exceed a distance of four
(4) feet. Balconies shall not be supported with posts extending to the sidewalk.
Mounting heights for balcony brackets shall conform to minimum clearance
standards.
5. Small building requirement. The following criteria shall apply to any building under
five thousand (5,000) square feet. Parking shall not wrap the building, but be limited
to the side and rear areas. Building height shall be limited to thirty-five (35) feet.
6. Building height. No building hereafter erected or structurally altered shall exceed a
height of sixty (60) feet, except as provided within the ordinance to allow cumulative
bonuses. Provide the maximum building height proposed.
7. Building setbacks from adjacent property lines and street rights -of -way shall be:
(1) Front yard setbacks may be zero (0) feet, but will not be more than twenty (20)
feet, excepting in those cases where grade changes make such setbacks
impractical. (2) Side yard setbacks may be zero (0), except where adjacent to lots
containing single-family detached structures. In this case the side yards shall have a
setback of not less than four (4) feet. (3) Rear yard setback may be zero (0), except
where adjacent to lots containing single-family detached structures. In this case the
rear yard shall have a setback of not less than twenty-five (25) feet. Provide the
Item # 5.1.
front building setback and the setback of the canopy from the right of way on
the site plan.
8. Driveways and internal circulation streets must have lanes at least ten (10) feet in
width, but not more than twelve (12) feet, excepting that width needed for bike lanes
or special pedestrian accommodations. Intersections of internal driveways or streets
will be minimally controlled by stop signs, and will feature special crossway paving or
treated surfaces. Access driveways running parallel to the street shall not create a
four-way intersection within one hundred twenty-five (125) feet of the ultimate curb
line of the public street. No more than one (1) curb cut per block face shall be
permitted. Driveways and parking lot entrance -exits shall be combined and where
appropriate located in alleys.
9. All driveways and internal streets shall have minimum five-foot sidewalks on both
sides located away from the back of curb. All sidewalks fronting buildings with
ground floor retail shall be at least ten (10) feet in width. Protected pedestrian
walkways shall be provided through parking lots. All developments shall include as
part of their site plan pedestrian linkages through parking areas and to adjacent
buildings or developments. The site plan does not include pedestrian linkages
from the adjacent buildings through the parking areas.
10.All new utilities for developments within the district shall be buried. All new
developments shall underground all utilities on site or within adjacent public right-of-
way whenever determined by the affected utility agency to be feasible. Trash
enclosures shall be located in alleys whenever available or in common service areas
for multiple developments. In all areas, service and waste removal areas shall be
screened and located away from public outdoor spaces and pedestrian. Dumpster
screening shall be as per 36-253. Dumpster facilities have not been included on
the site plan.
11. Parking facilities. Wherever feasible, multilevel parking structures shall be
encouraged. Surface parking shall be limited to the side and rear of structures,
unless grouped in quantities of fifty (50) spaces or less separated by a landscape
strip no less than the minimum perimeter landscape strip as required for the property
by chapter 15 of the Code [of Ordinances] or a structure from other vehicular areas
and having no more than one vehicular connection to another surfacing parking
area. Surface parking areas should be "broken up" or distributed around larger
structures so as to shorten the distance to other buildings and public sidewalks. For
corner lots, parking is allowed along the side street frontage. Parking requirements.
Parking requirements within the district shall be at least fifty (50) percent of that
required by article VIII. The maximum allowed parking shall be the minimum
standard established in article VII. Shared parking. As an alternative to subsection
(f)(2) above, mixed -use developments may utilize the shared parking methodologies
developed by the Urban Land Institute and published in Shared Parking (Second
Edition, 2005) by Mary S. Smith, et al. A project may elect this means of determining
the total parking requirement by submitting a parking demand analysis prepared by
a qualified parking or traffic consultant, a licensed architect, city planner, or urban
planner or civil engineer. On -street parking. On -street parking on internal streets or
circulation routes shall be allowed and may count towards the parking requirement.
On -street parking is permitted either parallel, in areas in front of, or adjacent to, retail
or commercial entries. Angled street (drive) parking shall not be permitted on streets
(drives) that provide the development majority access. Such parking may count
towards the overall project parking requirements. No on -street parking shall be
Item # 5.1.
allowed on University Avenue or Markham Street. Parking in setback. No parking
shall be allowed in the "front yard setback" area. Parking garage design. Parking
facilities should be designed consistent with the overall project design. Where
possible, other uses --residential or commercial --should be used to "wrap" or
otherwise block the view of a parking garage. Provide a parking demand
analysis prepared by a qualified parking or traffic consultant, a licensed
architect, city planner, or urban planner or civil engineer to determine the total
parking requirement.
12. Signage. Signage shall comply with provisions of article X of except as follows:
(1) No off -site advertising signs are permitted. (2) No pole -mounted signs are
permitted. (3) Monument signs are to identify the development and be limited to
seventy-two (72) square feet in area and six (6) feet in height for developments of
greater than one (1) acre. For developments less than one (1) acre monument signs
may be up to twenty-four (24) square feet in area and six (6) feet in height and must
be as located as part of the required landscape area of the parking lot. (4) Signage
integrated into freestanding vertical structures whose design theme and materials
are directly related to the primary development may be submitted for approval under
the planned zoning district process if located along University southerly of Lee. No
single elevation or face of such a structure shall be more than four hundred (400)
square feet. Provide details of the proposed signage. The DOD allows one
monument signs up to twenty-four (24) square feet in area and six (6) feet in
height. The sign must be located as part of the required landscape area.
13. Landscaping and public spaces. (1) No street buffer or landscaping shall be
required along streets classified less than an arterial. When the structure is not built
to the property line, landscaping is required in the area between the building and
property line up to that required in Chapter 15 of the Code [of Ordinances]. (2) Land
use buffers shall only be provided where single-family and duplex use or zoning is
the abutting use. In those cases where a land use buffer is required, buffers shall be
the same as those for multifamily uses in subsection 36-522(b)(1). In areas where
terrain variation is great or other features result in the loss of privacy, alternative
designs and massing shall be considered. (3) Common use areas and plazas shall
be a minimum of three hundred (300) square feet for thirty thousand (30,000)
square -foot structures. For each additional five thousand (5,000) square feet or
portion thereof, a minimum of an additional fifty (50) square feet of plaza area is
required. (4) Surface parking lots shall meet all current landscape requirements
(Chapter 15, article IV). (5) Street trees shall be a minimum of three-inch caliper and
shall be two (2) feet off the back of curb, thirty (30) feet on center. The canopy shall
be maintained with an eight -foot clearance. A four -foot planter strip shall be
maintained. (6) Common use areas and plazas shall be maintained by a common
authority. Attempts shall be made to maintain vegetation, trees, and bushes in
undisturbed conditions to serve the aesthetic, recreational and ecological needs of
the district. Trees planted in these areas shall be a minimum of two (2) inches in
caliper and ten (10) feet in height. (7) Trees greater than fourteen (14) inches in
diameter, measured at four and one-half (4.5) feet above the ground, shall be
protected from removal and damages in future development of the district. Any
development within fifty (50) feet of any such tree shall be reviewed prior to
development to assure protective measures are included and in place. When the
structure is not built to the property line, landscaping is required in the area
between the building and property line up to that required in Chapter 15 of the
Item # 5.1.
Code [of Ordinances]. Buffers along the north and east shall be the
those for multifamily uses in subsection 36-522(b)(1). Identify all tree
than 14" in diameter and provide the measures which will be taken t
Variance[Waivers: None requested.
Public Works Conditions:
o
intensity of exterior lighting. The intent is
nents from excessively illuminating the
night sky. (2) Only light fixtures which
es shall be permitted. The use of fully
encouraged. The Ordinance defines
r activities. Please see the table insert
1. Due to the proposed use of the property, the Master Street Plan specifies that C
Street for the frontage of this property must meet commercial street standards.
Dedicate right-of-way to 30 feet from centerline.
2. With site development, provide the design of street conforming to the Master Street
Plan. Construct one-half street improvement to C Street including 5-foot sidewalk
with the planned development. The new back of curb should be located 18 feet from
the centerline of the street and match the curb of the property to the west.
3. Repair or replace any curb and gutter or sidewalk that is damaged in the public right-
of-way prior to occupancy.
4. Plans of all work in right-of-way shall be submitted for approval prior to start of work.
Obtain barricade permit prior to doing any work in the right-of-way from Traffic
Engineering at (501) 379-1805 (Travis Herbner).
5. A grading permit in accordance with Section 29-186 (c) and (d) will be required prior
to any land clearing or grading activities at the site. Other than residential
subdivisions, site grading and drainage plans must be submitted and approved prior
to the start of construction.
6. A Sketch Grading and Drainage Plan should be provided per Section 29-186 (e).
7. Measures to control an increase in stormwater drainage should be implemented to
not cause damage onto adjacent property from the increased impervious area.
8. Provide the direction of flow and all storm water flows (Q) entering and leaving the
property.
9. Street Improvement plans shall include signage and striping. Traffic Engineering
must approve completed plans prior to construction.
10.The circle drive should be one way. Enter from the east driveway and exit on the
west driveway.
Utilities and Fire Department/County Planning:
Wastewater: Sewer available to this project.
Entergy: Approved as submitted.
Center -Point Ener : No comment received.
Item # 5.1.
AT & T: No comment received.
Central Arkansas Water: All Central Arkansas Water requirements in effect at the
time of request for water service must be met. A water main extension and additional
fire hydrant(s) will be required to provide adequate fire protection to this facility. Due to
the nature of this facility, installation of an approved reduced pressure zone backflow
preventer assembly (RPZ) is required on the domestic water service. This assembly
must be installed prior to the first point of use. Central Arkansas Water (CAW) requires
that upon installation of the RPZA, successful tests of the assembly must be completed
by a Certified Assembly Tester licensed by the State of Arkansas and approved by
CAW. The test results must be sent to CAW's Cross Connection Section within ten days
of installation and annually thereafter. Contact the Cross Connection Section at 377-
1226 if you would like to discuss backflow prevention requirements for this project.
Fire Department: Additional fire hydrants maybe required. Contact Little Rock Fire
Department for additional information.
County Planning: No comment.
CATA: The site is not located on a CATA Bus Route.
Planning Division: This request is located in the Heights Hillcrest Planning District. The
Land Use Plan shows Multi Family for this property. The applicant has applied for a
rezoning from R-3 Single Family to Planned Development Office to allow the
construction of a medical office/surgery center.
A Land Use Plan amendment (LU09-04-01) is a separate item on this agenda.
Master Street Plan: C Street is shown as a Local Street. The primary function of a
Local Street is to provide access to adjacent properties. Local Streets which are
abutted by non-residential zoning/use or more intensive zoning than duplexes are
considered as "Commercial Streets". These streets have a design standard the same
as a Collector. These streets may require dedication of right-of-way and may require
street improvements for entrances and exits to the site.
Bicycle Plan: There are no bike routes in the immediate vicinity.
Neiahborhood Action Plan: This area is covered by the Hillcrest Neighborhood Plan.
Their Zoning and Land Use goal states: "Adopt a plan of action to stop the degradation,
to reverse its course, and to recreate a neighborhood that is one again a pleasant place
to work and live. This includes no net loss of residential units by demolition or
conversion to other uses."
Landscape:
1. The site plan must comply with the City's landscape and buffer ordinance
requirements. The site plan must also comply with the Mid -Town DOD
requirements.
Item # 5.1.
2. An 117' foot land use buffer is required along the northern perimeter of the site. A
6'9" land use buffer is required along the sites eastern perimeter. Easements cannot
count toward full -filling this requirement. Seventy percent (70%) of the buffer area is
to remain undisturbed.
3. The landscape ordinance requires a minimum of 8% of the paved areas be
landscaped with interior islands of at least 7'/2 feet in width. Interior islands must be
a minimum of one hundred and fifty (150) square feet in area to qualify towards the
minimum landscape ordinance requirements. The existing parking lot must come
into compliance with the requirement.
4. A street buffer of 117' is required along C Street adjacent to the existing parking lot.
5. Street trees are required per the Mid -town DOD. Street trees shall be a minimum of
three-inch caliper and shall be two (2) feet off the back of curb, thirty (30) feet on
center. The canopy shall be maintained with an eight -foot clearance. A four -foot
planter strip shall be maintained.
6. Identify trees greater than 14 inches in diameter. Per the DOD trees greater than
fourteen (14) inches in diameter, measured at four and one-half (4.5) feet above the
ground, shall be protected from removal and damages in future development of the
district. Any development within fifty (50) feet of any such tree shall be reviewed
prior to development to assure protective measures are included and in place.
7. The street buffer adjacent to the building is required in accordance with Chapter 15
of the Code of Ordinances. The buffer required is six feet nine inches (69").
8. The landscape ordinance requires a minimum landscape strip of three feet (3) to be
located between the parking lot and the building.
9. A six (6) foot high opaque screen, either a wooden fence with its face side directed
outward, a wall, or dense evergreen plantings, is required along the northern and
eastern perimeters of the site. Credit towards fulfilling this requirement can be given
for existing trees and undergrowth that satisfies this year -around requirement.
Revised plat/plan: Submit four (4) copies of a revised preliminary plat/plan (to include
the additional information as noted above) to staff on Wednesday, April 15, 2009.
Item # 5.1.