Loading...
HomeMy WebLinkAboutZ-8383 Staff AnalysisAUGUST 25, 2008 ITEM NO.: 6 File No.: Owner: Applicant: Address: Description: Zoned: Z-8383 Ron and Kathy Blasingame Garrett Bosley/Bosley Construction, Inc. 4305 N. Lookout Lot 2, Block 14, Hillcrest Addition R-2 Variance Requested: A variance is requested from the height provisions of Section 36-254 to allow a single-family residence, which exceeds the maximum height allowed. Justification: The applicant's justification is presented in an attached letter. Present Use of Property: Single Family Residential Proposed Use of Property: Single Family Residential STAFF REPORT A. Public Works Issues: No Comments. B. Staff Analysis: The R-2 zoned property at 4305 N. Lookout is occupied by a two-story masonry single-family residence, which is in the process of being constructed. The new residence is flat roof -type construction. The single family lot slopes downward from back to front (south to north). Vehicular access to the property is by way of a paved alley along the south property line. The alley runs east from Walnut Street, which is west of the site. There is no vehicular access from N. Lookout. The height of the main portion of the new residence is 31.5 feet as measured from the lowest finished floor to the roof deck. A knee wall around the perimeter of the roof deck is 35 feet above the lowest finished floor. As part of the new home construction, a roof -top mechanical room was constructed to AUGUST 25, 2008 ITEM NO.: 6 (CON' house an elevator and stairway for access to the roof of the residence. The roof -top mechanical room is 12 feet by 16 feet in size and located along the west wall of the home. The mechanical room is 41' — 1" in height, as measured from the lowest finished floor to the roof deck. Section 36-254(c) of the City's Zoning Ordinance allows a maximum building height of 35 feet for R-2 zoned property. Section 36-2 defines building height as the vertical distance as measured through the central axis of the building from the elevation of the lowest finished floor level to the highest point of ceiling of the top story in the case of a flat roof. Therefore, the applicant is requesting a variance from this ordinance standard to allow the roof top mechanical room with a height of approximately 41' — 1 ". This property is within the Hillcrest Design Overlay District, which allows a building height of up to 39 feet, as measured from the "grade plane" to the ridge -line of the highest roof surface. However, the building permit was reviewed and issued prior to the approved Hillcrest DOD ordinance. Therefore, those standards do not apply to this particular development. Staff is supportive of the requested height variance. Staff views the request as reasonable. Although the new residence is taller than the adjacent homes, the height of the main portion of the structure complies with ordinance standards. Only a small portion of the overall building footprint (192 square feet) exceeds the maximum allowed height. Staff views the new residence as a quality in -fill project, and believes the building height of the roof -top mechanical room will have no adverse impact on the adjacent properties or the general area. C. Staff Recommendation: Staff recommends approval of the requested building height variance, subject to the variance being approved only for the roof -top mechanical room element of the residential structure. BOARD OF ADJUSTMENT: (AUGUST 25, 2008) The applicant was present. There were no objectors present. Staff presented the item and a recommendation of approval. The applicant offered no additional comments. The item was placed on the Consent Agenda and approved as recommended by staff by a vote of 4 ayes, 0 nays and 1 absent.