HomeMy WebLinkAboutPC Minutes for Z-9795-A 111523November 9, 2023
ITEM NO.: 12 FILE NO.: Z-9795-A
NAME: Queen Beans – PD-C
LOCATION: Northwest corner of Hermitage Road and Autumn Road
DEVELOPER:
Katie Mac (Queen Beans)
5400 Chenonceau Blvd. #920
Little Rock, AR 72223
OWNER/AUTHORIZED AGENT:
Jeremiah Russell (Agent)
Rogue Architecture
300 S. Spring Street
Little Rock, AR 72201
SURVEYOR/ENGINEER:
Koda Engineering
P.O. Box 26634
Bryant, AR 72022
AREA: 0.134 acre NUMBER OF LOTS: 1 FT. NEW STREET: 0 LF
WARD: 6 PLANNING DISTRICT: 4 CENSUS TRACT: 24.07
CURRENT ZONING: R-2
VARIANCE/WAIVERS:
Variance to allow reduced driveway spacing.
A. PROPOSAL/REQUEST/APPLICANT’S STATEMENT:
The applicant is requesting to rezone the property from R-2 to PD-C to allow for
the construction of Queen Beans (drive-thru only) Coffee Shop on a 0.24 acre tract
of land located adjacent to Chenal Parkway at the northwest corner of Hermitage
Road and Autumn Road. The site is located within the Chenal Overlay Design
District.
November 9, 2023
ITEM NO.: 12 (Cont.) FILE NO.: Z-9795-A
2
B. EXISTING CONDITIONS:
The property is in a primarily commercial area. The parcel is a triangular lot at the
corner of Hermitage Road and Chenal Parkway approximately 0.24 acre in area.
The surrounding zoning designations include C-3 Commercial as well as PUD and
PCD parcels.
C. NEIGHBORHOOD NOTIFICATIONS:
All owners of property located within 300 feet of the site and all neighborhood
associations registered with the City of Little Rock were notified of the public
hearing.
D. ENGINEERING COMMENTS:
1. Department engineering staff did not give approval for the traffic engineering
consultant who performed the traffic impact study submitted to use an
existing Queen Beans development in another city to estimate the volumes
of vehicular trips this proposed development will generate. Traffic
engineering consultant needs to use ITE Trip Gen. Category 938
(Coffee/Donut Shop with Drive-through and No Indoor Seating) for trip
generation calculations. This is the closest official land use category that
the consultant can use for this proposed development for analysis per ITE
Trip Generation Manual. When Department engineering staff use ITE Code
938 for trip generation calculations (360 sq.ft.), staff outputs 124 trips for AM
Peak hour (IN & OUT combined), instead of 26 trips combined per the
submitted traffic impact study. The expected queuing for this many trips will
block Hermitage Road & Autumn Road intersection as well as Chenal Pkwy.
& Autumn Road intersection. This anticipated queueing will shut down both
intersections creating adverse traffic operations for the traveling public and
business owners in the area. Traffic impact study shall be revised, re-
evaluated, and resubmitted for Department engineering staff’s review.
2. Future building permits will be required through the Department of Planning
and Development for any new buildings on site and be required to meet all
state building codes and land alteration codes and ordinances adopted by
the City of Little Rock.
3. Contact Planning and Development Dept., Engineering Division at
501-371-4817 or at 501-918-5348 for inspections of any work in the public
right-of-way prior to placement of concrete or asphalt or for on-site
clarification of requirements prior to commencing work. Failure to do so can
result in removal of any improperly placed concrete or asphalt at the
expense of the owner or contractor.
November 9, 2023
ITEM NO.: 12 (Cont.) FILE NO.: Z-9795-A
3
4. Any infrastructure within public right of way that is currently damaged or
damaged during construction will be repaired or replaced at developer’s
expense before a final certificate of occupancy can be released for the
building. This includes but not limited to the following: noncompliant curb and
gutter, asphalt, sidewalk, accessible ramps, storm drainage infrastructure,
or concrete driveway aprons. All work within the public right-of- way shall
conform to City of Little Rock Public Works Standard Details and ADA
accessibility requirements.
5. The Department requires three (3) phase sediment and erosion control
(SEC) plans to be submitted for all construction projects showing best
management practices (BMPs) for mitigating sediment runoff and erosion
along with vegetation specifications for temporary and permanent soil
stabilization. Phase 1 SEC plans shall show SEC BMPs during the
stripping, clearing, grubbing, and rough grading of the site. Phase 2 SEC
plans shall show SEC BMPs during construction of utilities, buildings,
roadway infrastructure and drainage infrastructure. Phase 3 SEC Plans
shall show SEC BMPs for final grading, seeding, and landscaping of the
site.
6. Sediment and Erosion Control plans shall also show the pertinent
information as outlined in ADEQ ARR150000 Permit Part II section A-4-H
(1-14) and Part II section A-4-I-2 (A-B).
7. A drainage study showing all hydrologic calculations for the site and all
hydraulic calculations for the proposed storm sewer pipe system, swales
and ditches, detention ponds, outlet structures, and inlets is required per
City’s stormwater management and drainage manual. For final drainage
report, sign, date, and seal the report per AR State Board of Professional
Engineers and Professional Surveyors rules Article 12, Section B (1) (a).
Provide engineer's certification statement saying this drainage report was
conducted by yourself or directly under your supervision and attesting to the
accuracy of the information within this report.
8. Per City Code 31-210 (e) (2) for collector streets, driveway spacing shall be
two- hundred fifty (250) feet. Driveway spacing shall be centerline to
centerline or centerline to right of way of an intersecting collector street or
street of higher classification. Minimum spacing from the property line shall
be one hundred twenty-five (125) feet. Revise driveway on site plan to meet
above requirements accordingly or request a variance from this City Code
requirement from the Planning Commission on the planned zoning
development application.
9. If a grading permit is not required for the proposed site work, all construction
work must include appropriate drainage and erosion control measures (i.e.,
silt fencing, mulching hydro-seeding, etc.) to protect the municipal storm
November 9, 2023
ITEM NO.: 12 (Cont.) FILE NO.: Z-9795-A
4
water drainage system and neighboring properties from sediment runoff.
New development may be subject to inspections for compliance.
E. UTILITIES/FIRE DEPARTMENT/PARKS/COUNTY PLANNING:
Little Rock Water Reclamation Authority: A sewer extension may be required.
Please submit wastewater plans to LRWRA for review and approval.
Entergy: No comments received.
Summit Utilities: No comments.
AT & T: No comments received.
Central Arkansas Water: No comments received.
Fire Department:
Maintain Access:
Fire Hydrants.
Maintain fire apparatus access roads at fire hydrant locations as per Appendix D
of the 2012 Arkansas Fire Prevention Code Vol. 1 Section D103.1 Access road
width with a hydrant. Where a fire hydrant is located on a fire apparatus access
road, the minimum road width shall be 26 feet, exclusive of shoulders.
Grade
Maintain fire apparatus access roads as per Appendix D of the 2012 Arkansas Fire
Prevention Code Vol. 1 Section D103.2 Grade. Fire apparatus access roads
shall not exceed 10 percent in grade except as approved by the fire chief. If
the grade exceeds 10 percent, approval will be denied and the applicant must
submit request to be reviewed by Fire Chief for Approval.
Loading
Maintain fire apparatus access road design as per Appendix D of the 2012
Arkansas Fire Prevention Code Vol. 1 Section D102.1 Access and loading.
Facilities, buildings or portions of buildings hereafter constructed shall be
accessible to fire department apparatus by way of an approved fire apparatus
access road with an asphalt, concrete or other approved driving surface capable
of supporting the imposed load of fire apparatus weighing at least 75,000 pounds.
November 9, 2023
ITEM NO.: 12 (Cont.) FILE NO.: Z-9795-A
5
Commercial and Industrial Developments – 2 means of access. - Maintain fire
apparatus access roads as per Appendix D of the 2012 Arkansas Fire Prevention
Code Vol. 1.
Section D104.1 Buildings exceeding three stories or 30 feet in height.
Building or facilities exceeding 30 feet or three stories in height shall have at least
two means of fire apparatus access for each structure.
Section D104.2 Building exceeding 62,000 square feet in area. Buildings or
facilities having a gross building area of more than 62,000 square feet shall be
provide with two separate and approved fire apparatus access roads.
Exception: Projects having a gross building area of up to 124,000 square feet
that have a single approved fire apparatus access road when all building are
equipped throughout with approved automatic sprinkler systems.
D104.3 Remoteness. Where two fire apparatus access roads are required, they
shall be placed a distance apart equal to not less than one half of the length of the
maximum overall diagonal dimension of the lot or area to be served, measured in
a straight line between accesses.
30’ Tall Buildings - Maintain aerial fire apparatus access roads as per
Appendix D of the 2012 Arkansas Fire Prevention Code Vol. 1 Section D105.1
– D105.4
D105.1 Where Required. Where the vertical distance between the grade
plane and the highest roof surface exceed 30’, approved aerial fire apparatus
access roads shall be provided. For the purposes of this section the highest roof
surfaces shall be determined by measurement to the eave of a pitched roof, the
intersection of a roof to the exterior wall, or the top of the parapet walls, whichever
is greater.
D105.2 Width. Aerial fire apparatus access roads shall have a minimum
unobstructed with of 26’, exclusive of shoulders, in the immediate vicinity of the
building or portion thereof.
D105.3 Proximity to building. At least one of the required access routes
meeting this condition shall be located within a minimum of 15 feet and a maximum
of 30 feet from the building, and shall be positioned parallel to one entire side of
the building. The side of the building on which the aerial fire apparatus access
road is positioned shall be approved by the fire code official.
D105.4 Obstructions. Overhead utility and power lines shall not be located
over the aerial fire apparatus access road or between the aerial fire apparatus road
and the building. Other obstructions shall be permitted to be places with the
approval of the fire code official.
November 9, 2023
ITEM NO.: 12 (Cont.) FILE NO.: Z-9795-A
6
Parks and Recreation: No comments received.
County Planning: No comments.
F. BUILDING CODES/LANDSCAPE:
Building Codes: No comments received.
Landscape:
1. Any new site development must comply with the City’s minimal landscape
and buffer ordinance requirements. Refer to the Code of Ordinances, Chapter
15 Landscaping and Tree Protection, and Chapter 36, Article IX – Buffers and
Screening.
2. A land use buffer equivalent to six (6) percent of the average width / depth of
the lot will be required when an adjacent property has a dissimilar use of a
more restrictive nature. As a component of all land use buffer requirements,
opaque screening, whether a fence or other device, a minimum of six (6) feet
in height shall be required upon the property line side of the buffer. A
minimum of seventy (70) percent of the land use buffer shall be undisturbed.
In addition to the required screening, buffers are to be landscaped at the rate
of one (1) tree and three (3) shrubs for every thirty (30) linear feet. Easements
cannot count toward fulfilling this requirement. The required screening shall
extend the full length of a property where any outside activity is located for
ten (10) feet on either side of such activity. The activities to be screened
include, but are not limited to, parking lots, drives, sanitation areas,
commercial static display of merchandise, loading docks, utility service
facilities and heating and air conditioning equipment. Where development
which requires screening abuts land use of a more restrictive nature at least
eighty (80) percent of the view of the vehicular use area and parked vehicles
shall be screened to not be visible when viewed from the adjacent property.
A wooden fence may satisfy sixty-five (65) percent of the requirement and
evergreen trees may be used to satisfy the balance. Screening standards
are intended to apply during all seasons of the year. A minimum of fifty (50)
percent of the trees and a minimum of seventy-five (75) percent of the shrubs
to be used for screening purposes shall be evergreen varieties. Maximum
spacings of fifteen (15) feet for trees and three (3) feet for shrubs should
normally be utilized in order to provide continuous full screening of the view.
3. Street buffers will be required at six (6) percent of the average depth of the
lot. The minimum dimension shall be one-half (½) the full width requirement
but in no case be less than nine (9) feet.
4. A perimeter planting strip is required along any side of a vehicular use area
that abuts adjoining property, or the right-of-way of any street. This strip shall
November 9, 2023
ITEM NO.: 12 (Cont.) FILE NO.: Z-9795-A
7
be at least nine (9) feet wide. One (1) tree and three (3) shrubs or vines shall
be planted for every thirty (30) linear feet of perimeter planting strip.
5. Building landscape areas shall be provided at the rate equivalent to planter
strip three (3) feet wide along the vehicular use area. One (1) tree and four
(4) shrubs shall be planted in the building landscape areas for each forty (40)
linear feet of vehicular use area abutting the building.
6. The interior landscape area of the vehicular use area shall, at a minimum,
equal eight percent (8%) of the vehicular use area and must be designated
for green space; this green space needs to be evenly distributed throughout
the parking area(s). The minimum size of an interior landscape area shall be
one hundred fifty (150) square feet for developments with one hundred fifty
(150) or fewer parking spaces. Interior islands must be a minimum seven
and one half (7 1/2) feet in width. Trees shall be included in the interior
landscape areas at the rate of one (1) tree for every twelve (12) parking
spaces. Please indicate the square footage of the areas considered for the
interior landscape area.
7. An automatic irrigation system to water landscaped areas shall be required
for developments of one (1) acre or larger. Developments of less than one
(1) acre shall have a water source within seventy-five (75) feet of the plants
to be irrigated.
8. All lawn areas shall be sodded with a regionally appropriate turfgrass species.
There should be no hydroseeding.
9. Evergreen shrubs should be containerized. All shrubs are to be a minimum
of 18 inches in height at installation.
10. At least fifty (50) percent of landscape areas shall be covered by live plant
material at the time of plant maturity.
11. The development of two (2) acres or more requires the landscape plan to be
stamped with the seal of a Registered Landscape Architect.
12. The City Beautiful Commission recommends preserving as many existing
trees as feasible on this site. Credit toward fulfilling Landscape Ordinance
requirements can be given when preserving trees of six (6) inch caliper
or larger.
G. TRANSPORTATION/PLANNING:
Rock Region Metro: No comments received.
Planning Division:
The request is in the I-430 Planning District. The Land Use Plan shows
Commercial (C) for the requested area. The Commercial (C) category includes a
broad range of retail and wholesale sales of products, personal and professional
November 9, 2023
ITEM NO.: 12 (Cont.) FILE NO.: Z-9795-A
8
services, and general business activities. Commercial activities vary in type and
scale, depending on the trade area that they serve. The application is to rezone
from R-2 to PD-C for a drive-thru coffee shop.
Surrounding the application area, west of Autumn Road on both sides of Chenal
Parkway is an area of Commercial (C). The Commercial (C) category includes a
broad range of retail and wholesale sales of products, personal and professional
services, and general business activities. Commercial activities vary in type and
scale, depending on the trade area that they serve. This area has restaurants,
home furnishing retail, electronics retail, mini-storage and strip commercial uses.
East of Autumn Road on both sides of Financial Center Parkway is an area of
Mixed Office Commercial (MOC). The Mixed Office and Commercial (MOC)
category provides for a mixture of office and commercial uses to occur. Acceptable
uses are office or mixed office and commercial. A Planned Zoning District is
required if the use is mixed office and commercial. Within this area are strip
commercial centers, offices, banking, and medical offices and institutions. The
area of MOC was amended by Ordinance 20847 in 2014 from Public/Institutional
(PI) and Commercial areas. Public/Institutional (PI) uses are public and quasi-
public facilities that provide a variety of services to the community such as schools,
libraries, fire stations, churches, utility substations, and hospitals.
This site is in the Chenal Parkway Overlay District.
Master Street Plan:
Chenal Parkway is a Principal Arterial with alternate design on the Master Street
Plan Map. Principal Arterials are roads designed to serve through traffic and to
connect major traffic generators or activity centers within urbanized areas. Right-
of-Way (ROW) of 100 feet is required. Sidewalks are required on both sides.
Access may need to be limited to ensure traffic flow and pedestrian safety.
Autumn Road is a Collector on the Master Street Plan Map. The primary function
of a Collector Road is to provide a connection from Local Streets to Arterials or
activity centers with the secondary function of providing access to adjoining
property. Standard Right-of-Way is 60 feet. Sidewalks are required on one side.
Hermitage Road is a local street on the Master Street Plan. A Local Street which
abuts non-residential or residential use which is more intense than duplex or two-
unit residential is a Commercial Street. Commercial Streets have the same design
standard as a Collector. Right-of-way is 60’. Sidewalks are required on both sides.
These streets may require dedication of additional right-of-way and may require
street improvements.
November 9, 2023
ITEM NO.: 12 (Cont.) FILE NO.: Z-9795-A
9
Bicycle Plan:
There are no existing or proposed bike routes adjacent to or through this land.
Historic Preservation Plan:
There are no Historic Sites or Districts in the vicinity.
H. ANALYSIS:
The applicant is requesting to rezone the property from R-2 to PD-C to allow for
the construction of Queen Beans (drive-thru only) Coffee Shop on a 0.24 acre tract
of land located adjacent to Chenal Parkway at the northwest corner of Hermitage
Road and Autumn Road. The site is located within the Chenal Overlay Design
District.
The property is in a primarily commercial area. The parcel is a triangular lot at the
corner of Hermitage Road and Autumn Road. The surrounding property
designations include C-3 Commercial as well as PUD and PCD parcels.
Access is provided by a twenty-four (24) foot wide drive extending from Hermitage
Road. Based on the design, ingress/egress will be right in, right out only, entering
from and exiting to Hermitage Road.
The applicant proposes to construct a 12’x30’ (360 square foot) building in the
northeast portion of the site with and elevation of eighteen (18) feet in height. The
menu board is located on the northeast corner of the building. The traffic design
shows lot circulation flowing from east to west as you enter from Hermitage Road
leading to the pick-up window northwest corner of the building.
Operating hours will be Monday-Friday from 5:00am to 7:00pm, Saturday and
Sunday from 7:00am to 4:00pm with a maximum number of four (4) employees at
any given time.
The site plan shows three (3) parking spaces located in the western portion of the
site and includes one (1) ADA compliant parking space. A five (5) foot walk way
extends from the parking area to building entrance on the south side of the building.
A dumpster enclosure is shown in the southwest portion of the site. The dumpster
shall be screened as per Section 36523 of the City’s Zoning Ordinance.
No signage is proposed at this time. All signage must comply with Section 36-349
of the Chenal/Financial Center Overlay District.
All site lighting must be low-level and directed away from adjacent properties.
November 9, 2023
ITEM NO.: 12 (Cont.) FILE NO.: Z-9795-A
10
Per City Code 31-210(e)(2) for collector streets, driveway spacing shall be two-
hundred fifty (250) feet. Driveway spacing shall be centerline to centerline or
centerline to right-of-way of an intersecting collector street or street of higher
classification. Minimum spacing from the property line shall be one hundred
twenty-five (125) feet. The applicant is requesting a variance to allow reduced
driveway spacing for the proposed driveway. Staff supports the variance request,
as the proposed driveway location is the best possible drive location for this site.
Staff is supportive of the PD-C rezoning. To staff’s knowledge, there are no
outstanding issues with this application. Staff feels the proposed use is consistent
with existing commercial developments in the area and should have no adverse
impact on the surrounding properties.
I. STAFF RECOMMENDATION:
Staff recommends approval of the requested PD-C rezoning including the variance
request, subject to compliance with the comments and conditions in paragraphs
D, E and F, and the staff analysis, of the agenda staff report.
PLANNING COMMISSION ACTION: (NOVEMBER 9, 2023)
This item is being deferred to the December 14, 2023 agenda due to lack of notification.
No vote was taken.