HomeMy WebLinkAboutZ-8367 Map 3STANDARD PARKING SPACES - 50
HANDICAP PARKING SPACES - 3
TOTAL PARKING SPACES - 53
YY. I L I I -I J I Ktt I
60'$R.O.W. (B-B=45')
n.b
SITE PLAN
GRAPHIC SCALE IN FEET
20' 0 20'
NOTIFICATION OF LIMITED SERVICES
CRAFTON, TULL, SPARKS & ASSOCIATES, INC., (CTSA) HAS
NOT BEEN RETAINED BY THE OWNER FOR CONSTRUCTION
ADMINISTRATION OR OBSERVATION SERVICES ON ALL OR A
(PORTION OF THE WORK INDICATED ON THESE DRAWINGS.
THEREFORE, THE CTSA HEREBY NOTIFIES ALL PARTIES
INVOLVED THAT THE CTSA ASSUMES NO RESPONSIBILITY FOR
THE INTERPRETATION, COORDINATION AND ADMINISTRATION OF
THESE DOCUMENTS AND/OR DEVIATIONS THEREFROM AND THE
EFFECTS THOSE CHANGES MAY HAVE ON ANY AND ALL
RELATED TRADES OR CONSTRUCTION SEQUENCES, OR
OPERATION OF THE COMPLETED PROJECT, EXCEPT AS SPEC-
IFICALLY REQUIRED IN THE CTSA's SERVICES AGREEMENT WITH
THE OWNER.
ENGINEER'S NOTICE TO CONTRACTOR
THE EXISTENCE AND LOCATION OF ANY UNDERGROUND
UTILITY PIPES OR STRUCTURES SHOWN ON THESE DRAWINGS
ARE OBTAINED BY A SEARCH OF THE AVAILABLE RECORDS.
TO THE BEST OF OUR KNOWLEDGE THERE ARE NO EXISTING
UTILITIES EXCEPT AS SHOWN ON THESE DRAWINGS AND WE
ASSUME NO RESPONSIBILITY AS TO THE ACCURACY OF
THEIR DEPICTED LOCATION ON THESE DRAWINGS. THE
CONTRACTOR IS REQUIRED TO TAKE DUE PRECAUTIONARY
MEASURES TO PROTECT THE UTILITY LINES SHOWN, AND
ALL OTHER LINES NOT OF RECORD OR NOT SHOWN ON THESE
DRAWINGS BY VERIFICATION OF THEIR LOCATION IN THE
FIELD PRIOR TO THE INITIATION OF THE ACTUAL PORTION
OF THEIR WORK.
SAFETY NOTICE TO CONTRACTOR
IN ACCORDANCE WITH GENERALLY ACCEPTED CONSTRUCTION
PRACTICES, THE CONTRACTOR WILL BE SOLELY AND
COMPLETELY RESPONSIBLE FOR CONDITIONS OF THE JOB
SITE, INCLUDING SAFETY OF ALL PERSONS AND PROPERTY
DURING PERFORMANCE OF THE WORK. THIS REQUIREMENT
WILL APPLY CONTINUOUSLY AND NOT BE LIMITED TO
NORMAL WORKING HOURS.
THE DUTY OF THE ENGINEER TO CONDUCT CONSTRUCTION
REVIEW OF THE CONTRACTOR'S PERFORMANCE IS NOT
INTENDED TO INCLUDE REVIEW OF THE ADEQUACY OF THE
CONTRACTOR'S SAFETY MEASURES, IN, OR NEAR THE
CONSTRUCTION SITE.
OWNERSHIP OF DOCUMENTS
THIS DOCUMENT, AND THE IDEAS AND DESIGNS
INCORPORATED HEREIN, AS AN INSTRUMENT OF
PROFESSIONAL SERVICES, IS THE PROPERTY OF CRAFTON,
TULL, SPARKS & ASSOCIATES, INC., AND IS NOT TO BE
USED, IN WHOLE OR PART, FOR ANY OTHER PROJECT WITH
OUT THE WRITTEN AUTHORIZATION OF CRAFTON, TULL.
SPARKS & ASSOCIATES, INC.
SITE NOTES
1. ALL WORK AND MATERIALS SHALL COMPLY WITH ALL
CITY/COUNTY/STATE/FEDERAL REGULATIONS AND CODES AND OSHA
STANDARDS.
2. CONTRACTOR SHALL REFER TO ARCHITECTURAL PLANS FOR EXACT
LOCATIONS AND DIMENSIONS OF VESTIBULES, SLOPE PAVING,
SIDEWALKS, EXIT PORCHES, TRUCK DOCKS, PRECISE BUILDING
DIMENSIONS AND EXACT UTILITY ENTRANCE LOCATIONS.
3. ALL DIMENSIONS AND RADII ARE TO BACK OF CURB UNLESS OTHERWI
NOTED.
4. ALL WORK SHALL BE DONE IN STRICT ACCORDANCE WITH THE PROJEC
SPECIFICATIONS.
5. ALL CURB/SIDEWALK/HANDICAP RAMP DESIGNS SHALL CONFORM TO
ADA STANDARDS OR LOCAL RESTRICTIVE CODES, WHICHEVER IS MORE
RESTRICTIVE.
6. CONTRACTOR SHALL ENSURE ALL NECESSARY PERMITS ARE OBTAINED
PRIOR TO CONSTRUCTION START.
7. CONTRACTOR SHALL MATCH PROPOSED CURB AND GUTTER, CONCRETE,
AND PAVEMENT TO EXISTING IN GRADE AND ALIGNMENT.
8, CONTRACTOR SHALL MAINTAIN ALL EXISTING PARKING, SIDEWALKS,
DRIVES, ETC, CLEAR AND FREE FROM ANY CONSTRUCTION ACTIVITY
AND/OR MATERIAL TO ENSURE EASY AND SAFE PEDESTRIAN AND
VEHICULAR TRAFFIC TO AND FROM THE SITE.
SET IRON PIN
LIGHT POLE
POWER POLE
TELEPHONE PEDESTAL
TV PEDESTAL
MANHOLE
SANITARY SEWER CLEANOUT
GAS METER
GAS VALVE
STORM SEWER PIPE
STRUCTURE NUMBER
WATER VALVE
FIRE HYDRANT ASSEMBLY
AIR RELEASE VALVE
FIRE DEPARTMENT CONNECTION
WATER METER
BACK FLOW PREVENTER
REDUCER
PLUG VALVE
1►1�1'1 i
EASEMENT
CURB
INTERMEDIATE CONTOUR
INDEX CONTOUR
SANITARY SEWER LINE
GAS LINE
WATER LINE
UNDERGROUND TELEPHONE
UNDERGROUND ELECTRIC
OVERHEAD ELECTRIC
FIBER OPTIC
GRATED INLET UNDERGROUND TELEVISION
OVERHEAD TELEVISION
DROP INLET
CHAIN LINK FENCE
WOOD FENCE
BARBED WIRE FENCE
BUILDING SET BACK
RIGHT OF WAY
PROPERTY LINE
FOUND IRON PIN
LIGHT POLE
POWER POLE
TELEPHONE PEDESTAL
TV PEDESTAL
MANHOLE
SANITARY SEWER CLEANOUT
GAS METER
GAS VALVE
STORM SEWER PIPE
DOWN GUY
WATER VALVE
FIRE HYDRANT ASSEMBLY
AIR RELEASE VALVE
FIRE DEPARTMENT CONNECTION
WATER METER
SPRINKLER HEAD
ELECTRIC PEDESTAL
GRATED INLET
DROP INLET
WWII
TREE TO BE REMOVED
GENERAL NOTES
1. ENGINEER'S NOTICE TO CONTRACTOR: THE EXISTENCE AND LOCATION OF ANY UNDERGROUND UTILITY PIPES OR
STRUCTURES SHOWN ON THESE DRAWINGS ARE OBTAINED BY A SEARCH OF THE AVAILABLE RECORDS. TO THE
BEST OF OUR KNOWLEDGE THERE ARE NO EXISTING UTILITIES EXCEPT AS SHOWN ON THESE DRAWINGS AND
WE ASSUME NO RESPONSIBILITY AS TO THE ACCURACY OF THEIR DEPICTED LOCATION ON THESE DRAWINGS.
THE CONTRACTOR IS REQUIRED TO TAKE DUE PRECAUTIONARY MEASURES TO PROTECT THE UTILITY LINES
SHOWN, AND ALL OTHER LINES NOT OF RECORD OR NOT SHOWN ON THESE DRAWINGS BY VERIFICATION OF
THEIR LOCATION IN THE FIELD PRIOR TO THE INITIATION OF THE ACTUAL PORTION OF THEIR WORK.
2. SAFETY NOTICE TO CONTRACTOR: IN ACCORDANCE WITH GENERALLY ACCEPTED CONSTRUCTION PRACTICES, THE
CONTRACTOR WILL BE SOLELY AND COMPLETELY RESPONSIBLE FOR CONDITIONS OF THE JOB SITE, INCLUDING
SAFETY OF ALL PERSONS AND PROPERTY DURING PERFORMANCE OF THE WORK. THIS REQUIREMENT WILL
APPLY CONTINUOUSLY AND NOT BE LIMITED TO NORMAL WORKING HOURS. THE DUTY OF THE ENGINEER TO
CONDUCT CONSTRUCTION REVIEW OF THE CONTRACTOR'S PERFORMANCE IS NOT INTENDED TO INCLUDE REVIEW
OF THE ADEQUACY OF THE CONTRACTOR'S SAFETY MEASURES, IN, OR NEAR THE CONSTRUCTION SITE.
3. OWNERSHIP OF DOCUMENTS: THIS DOCUMENT, AND THE IDEAS AND DESIGNS INCORPORATED HEREIN, AS AN
INSTRUMENT OF PROFESSIONAL SERVICES, IS THE PROPERTY OF CRAFTON, TULL, SPARKS & ASSOCIATES, INC.,
AND IS NOT TO BE USED, IN WHOLE OR PART, FOR ANY OTHER PROJECT WITHOUT THE WRITTEN
AUTHORIZATION OF CRAFTON, TULL, SPARKS & ASSOCIATES, INC.
4. CONTRACTOR SHALL NOT CAUSE ANY INCONVENIENCE TO THE PUBLIC, ADJACENT PROPERTY OWNERS,
PEDESTRIANS, ETC. DURING THE CONSTRUCTION OF THIS PROJECT. THE CONTRACTOR SHALL NOT DISRUPT
ACCESS TO ADJACENT PROPERTIES AT ANY TIME DURING CONSTRUCTION.
5. THE CONTRACTOR SHALL CONTACT THE ENGINEER FOR CLARIFICATION IF A DISCREPANCY OR INCONSISTENCY
IS IDENTIFIED ON THE PLANS AND/OR SPECIFICATIONS.
6. CONTRACTOR IS RESPONSIBLE FOR THE DESIGN AND IMPLEMENTATION OF ALL REQUIRED/NECESSARY
SHEETING, SHORING, AND SPECIAL EXCAVATION MEASURES REQUIRED ON THE PROJECT TO MEET OSHA,
FEDERAL, STATE AND LOCAL REGULATIONS.
LINEWORK
EASEMENT-_-----
5W0
-1206
INTERMEDIATE CONTOUR
1205 ....
IN CONTOUR
SANITARY SEWER LINE
GAS LINE
WATER LINE (SPECIFY SIZE & TYPE)
UNDERGROUND TELEPHONE
(11�1►]�:iel:i►11L`I►hl#X+111:[[�7
OVERHEAD ELECTRIC
UNDERGROUND TELEVISION
OVERHEAD TELEVISION
CHAIN LINK FENCE
WOOD FENCE
BARBED WIRE FENCE
FIBER OPTIC
RIGHT OF WAY
DRAWINGS, WRITTEN MATERIAL, AND DESIGN CONCEPTS SHALL
NOT BE USED OR REPRODUCED IN WHOLE OR PART IN ANY FORM
WITHOUT PRIOR CONSENT OF ROARK PERKINS PERRY
YELVINGTON ARCHITECTS. DO NOT SCALE DRAWINGS. USE
GIVEN DIMENSIONS ONLY. IF NOT SHOWN, VERIFY DIMENSIONS
WITH THE ARCHITECT. CONTRACTOR SHALL CHECK AND VERIFY
ALL DIMENSIONS AND CONDITIONS AT JOB SITE.
z
N
W
N
N�
o
N
O�
OC
o
z
®z�
Fes-
w
<
J
L
z�1-z
I.-
~3
LU
o
Lu
0
w
w
w
03�
�z
W
Z
W
U
U)
[n
LLIIr
Y
Wi-Q
U
Y
=
U
O
U.T
N
fr
Lu
J
LL
Lu
REVISIONS DATE
a
4
=4 sue
NO
', •! •
SHEET OF