Loading...
HomeMy WebLinkAboutZ-8367 Map 3STANDARD PARKING SPACES - 50 HANDICAP PARKING SPACES - 3 TOTAL PARKING SPACES - 53 YY. I L I I -I J I Ktt I 60'$R.O.W. (B-B=45') n.b SITE PLAN GRAPHIC SCALE IN FEET 20' 0 20' NOTIFICATION OF LIMITED SERVICES CRAFTON, TULL, SPARKS & ASSOCIATES, INC., (CTSA) HAS NOT BEEN RETAINED BY THE OWNER FOR CONSTRUCTION ADMINISTRATION OR OBSERVATION SERVICES ON ALL OR A (PORTION OF THE WORK INDICATED ON THESE DRAWINGS. THEREFORE, THE CTSA HEREBY NOTIFIES ALL PARTIES INVOLVED THAT THE CTSA ASSUMES NO RESPONSIBILITY FOR THE INTERPRETATION, COORDINATION AND ADMINISTRATION OF THESE DOCUMENTS AND/OR DEVIATIONS THEREFROM AND THE EFFECTS THOSE CHANGES MAY HAVE ON ANY AND ALL RELATED TRADES OR CONSTRUCTION SEQUENCES, OR OPERATION OF THE COMPLETED PROJECT, EXCEPT AS SPEC- IFICALLY REQUIRED IN THE CTSA's SERVICES AGREEMENT WITH THE OWNER. ENGINEER'S NOTICE TO CONTRACTOR THE EXISTENCE AND LOCATION OF ANY UNDERGROUND UTILITY PIPES OR STRUCTURES SHOWN ON THESE DRAWINGS ARE OBTAINED BY A SEARCH OF THE AVAILABLE RECORDS. TO THE BEST OF OUR KNOWLEDGE THERE ARE NO EXISTING UTILITIES EXCEPT AS SHOWN ON THESE DRAWINGS AND WE ASSUME NO RESPONSIBILITY AS TO THE ACCURACY OF THEIR DEPICTED LOCATION ON THESE DRAWINGS. THE CONTRACTOR IS REQUIRED TO TAKE DUE PRECAUTIONARY MEASURES TO PROTECT THE UTILITY LINES SHOWN, AND ALL OTHER LINES NOT OF RECORD OR NOT SHOWN ON THESE DRAWINGS BY VERIFICATION OF THEIR LOCATION IN THE FIELD PRIOR TO THE INITIATION OF THE ACTUAL PORTION OF THEIR WORK. SAFETY NOTICE TO CONTRACTOR IN ACCORDANCE WITH GENERALLY ACCEPTED CONSTRUCTION PRACTICES, THE CONTRACTOR WILL BE SOLELY AND COMPLETELY RESPONSIBLE FOR CONDITIONS OF THE JOB SITE, INCLUDING SAFETY OF ALL PERSONS AND PROPERTY DURING PERFORMANCE OF THE WORK. THIS REQUIREMENT WILL APPLY CONTINUOUSLY AND NOT BE LIMITED TO NORMAL WORKING HOURS. THE DUTY OF THE ENGINEER TO CONDUCT CONSTRUCTION REVIEW OF THE CONTRACTOR'S PERFORMANCE IS NOT INTENDED TO INCLUDE REVIEW OF THE ADEQUACY OF THE CONTRACTOR'S SAFETY MEASURES, IN, OR NEAR THE CONSTRUCTION SITE. OWNERSHIP OF DOCUMENTS THIS DOCUMENT, AND THE IDEAS AND DESIGNS INCORPORATED HEREIN, AS AN INSTRUMENT OF PROFESSIONAL SERVICES, IS THE PROPERTY OF CRAFTON, TULL, SPARKS & ASSOCIATES, INC., AND IS NOT TO BE USED, IN WHOLE OR PART, FOR ANY OTHER PROJECT WITH OUT THE WRITTEN AUTHORIZATION OF CRAFTON, TULL. SPARKS & ASSOCIATES, INC. SITE NOTES 1. ALL WORK AND MATERIALS SHALL COMPLY WITH ALL CITY/COUNTY/STATE/FEDERAL REGULATIONS AND CODES AND OSHA STANDARDS. 2. CONTRACTOR SHALL REFER TO ARCHITECTURAL PLANS FOR EXACT LOCATIONS AND DIMENSIONS OF VESTIBULES, SLOPE PAVING, SIDEWALKS, EXIT PORCHES, TRUCK DOCKS, PRECISE BUILDING DIMENSIONS AND EXACT UTILITY ENTRANCE LOCATIONS. 3. ALL DIMENSIONS AND RADII ARE TO BACK OF CURB UNLESS OTHERWI NOTED. 4. ALL WORK SHALL BE DONE IN STRICT ACCORDANCE WITH THE PROJEC SPECIFICATIONS. 5. ALL CURB/SIDEWALK/HANDICAP RAMP DESIGNS SHALL CONFORM TO ADA STANDARDS OR LOCAL RESTRICTIVE CODES, WHICHEVER IS MORE RESTRICTIVE. 6. CONTRACTOR SHALL ENSURE ALL NECESSARY PERMITS ARE OBTAINED PRIOR TO CONSTRUCTION START. 7. CONTRACTOR SHALL MATCH PROPOSED CURB AND GUTTER, CONCRETE, AND PAVEMENT TO EXISTING IN GRADE AND ALIGNMENT. 8, CONTRACTOR SHALL MAINTAIN ALL EXISTING PARKING, SIDEWALKS, DRIVES, ETC, CLEAR AND FREE FROM ANY CONSTRUCTION ACTIVITY AND/OR MATERIAL TO ENSURE EASY AND SAFE PEDESTRIAN AND VEHICULAR TRAFFIC TO AND FROM THE SITE. SET IRON PIN LIGHT POLE POWER POLE TELEPHONE PEDESTAL TV PEDESTAL MANHOLE SANITARY SEWER CLEANOUT GAS METER GAS VALVE STORM SEWER PIPE STRUCTURE NUMBER WATER VALVE FIRE HYDRANT ASSEMBLY AIR RELEASE VALVE FIRE DEPARTMENT CONNECTION WATER METER BACK FLOW PREVENTER REDUCER PLUG VALVE 1►1�1'1 i EASEMENT CURB INTERMEDIATE CONTOUR INDEX CONTOUR SANITARY SEWER LINE GAS LINE WATER LINE UNDERGROUND TELEPHONE UNDERGROUND ELECTRIC OVERHEAD ELECTRIC FIBER OPTIC GRATED INLET UNDERGROUND TELEVISION OVERHEAD TELEVISION DROP INLET CHAIN LINK FENCE WOOD FENCE BARBED WIRE FENCE BUILDING SET BACK RIGHT OF WAY PROPERTY LINE FOUND IRON PIN LIGHT POLE POWER POLE TELEPHONE PEDESTAL TV PEDESTAL MANHOLE SANITARY SEWER CLEANOUT GAS METER GAS VALVE STORM SEWER PIPE DOWN GUY WATER VALVE FIRE HYDRANT ASSEMBLY AIR RELEASE VALVE FIRE DEPARTMENT CONNECTION WATER METER SPRINKLER HEAD ELECTRIC PEDESTAL GRATED INLET DROP INLET WWII TREE TO BE REMOVED GENERAL NOTES 1. ENGINEER'S NOTICE TO CONTRACTOR: THE EXISTENCE AND LOCATION OF ANY UNDERGROUND UTILITY PIPES OR STRUCTURES SHOWN ON THESE DRAWINGS ARE OBTAINED BY A SEARCH OF THE AVAILABLE RECORDS. TO THE BEST OF OUR KNOWLEDGE THERE ARE NO EXISTING UTILITIES EXCEPT AS SHOWN ON THESE DRAWINGS AND WE ASSUME NO RESPONSIBILITY AS TO THE ACCURACY OF THEIR DEPICTED LOCATION ON THESE DRAWINGS. THE CONTRACTOR IS REQUIRED TO TAKE DUE PRECAUTIONARY MEASURES TO PROTECT THE UTILITY LINES SHOWN, AND ALL OTHER LINES NOT OF RECORD OR NOT SHOWN ON THESE DRAWINGS BY VERIFICATION OF THEIR LOCATION IN THE FIELD PRIOR TO THE INITIATION OF THE ACTUAL PORTION OF THEIR WORK. 2. SAFETY NOTICE TO CONTRACTOR: IN ACCORDANCE WITH GENERALLY ACCEPTED CONSTRUCTION PRACTICES, THE CONTRACTOR WILL BE SOLELY AND COMPLETELY RESPONSIBLE FOR CONDITIONS OF THE JOB SITE, INCLUDING SAFETY OF ALL PERSONS AND PROPERTY DURING PERFORMANCE OF THE WORK. THIS REQUIREMENT WILL APPLY CONTINUOUSLY AND NOT BE LIMITED TO NORMAL WORKING HOURS. THE DUTY OF THE ENGINEER TO CONDUCT CONSTRUCTION REVIEW OF THE CONTRACTOR'S PERFORMANCE IS NOT INTENDED TO INCLUDE REVIEW OF THE ADEQUACY OF THE CONTRACTOR'S SAFETY MEASURES, IN, OR NEAR THE CONSTRUCTION SITE. 3. OWNERSHIP OF DOCUMENTS: THIS DOCUMENT, AND THE IDEAS AND DESIGNS INCORPORATED HEREIN, AS AN INSTRUMENT OF PROFESSIONAL SERVICES, IS THE PROPERTY OF CRAFTON, TULL, SPARKS & ASSOCIATES, INC., AND IS NOT TO BE USED, IN WHOLE OR PART, FOR ANY OTHER PROJECT WITHOUT THE WRITTEN AUTHORIZATION OF CRAFTON, TULL, SPARKS & ASSOCIATES, INC. 4. CONTRACTOR SHALL NOT CAUSE ANY INCONVENIENCE TO THE PUBLIC, ADJACENT PROPERTY OWNERS, PEDESTRIANS, ETC. DURING THE CONSTRUCTION OF THIS PROJECT. THE CONTRACTOR SHALL NOT DISRUPT ACCESS TO ADJACENT PROPERTIES AT ANY TIME DURING CONSTRUCTION. 5. THE CONTRACTOR SHALL CONTACT THE ENGINEER FOR CLARIFICATION IF A DISCREPANCY OR INCONSISTENCY IS IDENTIFIED ON THE PLANS AND/OR SPECIFICATIONS. 6. CONTRACTOR IS RESPONSIBLE FOR THE DESIGN AND IMPLEMENTATION OF ALL REQUIRED/NECESSARY SHEETING, SHORING, AND SPECIAL EXCAVATION MEASURES REQUIRED ON THE PROJECT TO MEET OSHA, FEDERAL, STATE AND LOCAL REGULATIONS. LINEWORK EASEMENT-_----- 5W0 -1206 INTERMEDIATE CONTOUR 1205 .... IN CONTOUR SANITARY SEWER LINE GAS LINE WATER LINE (SPECIFY SIZE & TYPE) UNDERGROUND TELEPHONE (11�1►]�:iel:i►11L`I►hl#X+111:[[�7 OVERHEAD ELECTRIC UNDERGROUND TELEVISION OVERHEAD TELEVISION CHAIN LINK FENCE WOOD FENCE BARBED WIRE FENCE FIBER OPTIC RIGHT OF WAY DRAWINGS, WRITTEN MATERIAL, AND DESIGN CONCEPTS SHALL NOT BE USED OR REPRODUCED IN WHOLE OR PART IN ANY FORM WITHOUT PRIOR CONSENT OF ROARK PERKINS PERRY YELVINGTON ARCHITECTS. DO NOT SCALE DRAWINGS. USE GIVEN DIMENSIONS ONLY. IF NOT SHOWN, VERIFY DIMENSIONS WITH THE ARCHITECT. CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS AND CONDITIONS AT JOB SITE. z N W N N� o N O� OC o z ®z� Fes- w < J L z�1-z I.- ~3 LU o Lu 0 w w w 03� �z W Z W U U) [n LLIIr Y Wi-Q U Y = U O U.T N fr Lu J LL Lu REVISIONS DATE a 4 =4 sue NO ', •! • SHEET OF