HomeMy WebLinkAboutZ-8367 Map 1SSMH 3' CONC. FLUME
i
-----ffi W/SIDEWALK GRATE
--------------
PROPOSED
ACCESSIBLE
HC RAMP/W
TACTILE PANEL
CONC.
APRON
NEW
24" CURB AND
GUTTER
cD
N
w ao
W
m
J
Q O
0
Ln
CONC.
TRANSFORMER
PAD
CONC.
APRON
PROPOSED
ACCESSIBLE
HC RAMP/W
TACTILE PANEL
11TH STREET
__ 25' R.O.W. (ASPHALT VAIRES)
22.0'--------
7TTTPRO
POSED
ACCESSIBLE
H( R'AMP/W
91 0' TACTILE PANEL
14.0'
� NEW HC
a AISLE (TYPJ SPACE (TYP.) 6.0
R5.0' 9.0' 9.0' �s
NEW STRIPING
3' CONC. FLUME
W/SIDEWALK GRATE
p
64.0'
o _
6.0, N `O ,
NC.
FLUME
T-7
8.0' 55.0'
NEW STRIPING
(
i
SSM�
5.0' TOP:i 395.6I
r�l
% APRON
i
PROPOSED
ACCESSIBLE
HC RAMP/W
TACTILE PANEL
NEW
24" CURB
GUTTER
1
^ "" "^"
SCREEN WALL)
j
k
{
GATE
?'
0
•
: q
o
SSMH
3 _(
O
3-2
WOMEN'S DORMITO
TOP: 38
;52
COURTYARD
FIFE = 392.00
N'S DORMITORY
Lo COURTYARD
FE = 392.00
0
10.3'
2"
Cedar
AC UNIT
•0'
LW
ON CONC. PAD
AC UNIT
40" Oak y
11.5'
11.5'r
ON CONC. PAD
� �)
w
>
I
WOOENCE l`
6:0
o
o
z
a
Rti
®
®
I
3 Oako
F
Q
-
Z
CONC.
-
W
.
STAIRS
r-------------
O
GARAGE
ASPI IALT
......
• .. • . � � � 10..
THE CENTER TREATMENT CEN R _
OFFICE
. .. .
FIFE = 378.00
3' LOADING
SOCK STAIRS
TO BALCONY
00
�p2
SCREENED
DUMPS TER
5,0 T77T r= iii ni -
....
PS
i 6.4' 5.b'
z
0
L------ 23.0'
RETAINING �__
a12"
WALL
edbud CONC. STEPS
BALCONY
ABOVE
36.3'
3.6,
5.0' CONCRtTE SIDEWALK 51.9 _ i 37.1
C• 7.5
STANDARD PARKING SPACES - 50
HANDICAP PARKING SPACES - 3
TOTAL PARKING SPACES - 53
EXISTING 8" WATERLINE
G 6" SEWER LINE W. 12TH STREET NEW
---$----x-- a__ 24"
60'$ R.O.W. (B-B=45') GUT
SITE PLAN
11.4'
EX. BLDG
20" Oak
0
TCH
-7� O
I. I Un
1 8" Oy k
1 8' , Old k
2"I OAK
4*��
GRAPHIC SCALE IN FEET
20' 0 20'
NOTIFICATION OF LIMITED SERVICES
CRAFTON, TULL, SPARKS & ASSOCIATES, INC., (CTSA) HAS
NOT BEEN RETAINED BY THE OWNER FOR CONSTRUCTION
ADMINISTRATION OR OBSERVATION SERVICES ON ALL OR A
PORTION OF THE WORK INDICATED ON THESE DRAWINGS.
THEREFORE, THE CTSA HEREBY NOTIFIES ALL PARTIES
INVOLVED THAT THE CTSA ASSUMES NO RESPONSIBILITY FOR
THE INTERPRETATION, COORDINATION AND ADMINISTRATION OF
THESE DOCUMENTS AND/OR DEVIATIONS THEREFROM AND THE
EFFECTS THOSE CHANGES MAY HAVE ON ANY AND ALL
RELATED TRADES OR CONSTRUCTION SEQUENCES, OR
OPERATION OF THE COMPLETED PROJECT, EXCEPT AS SPEC-
IFICALLY REQUIRED IN THE CTSA's SERVICES AGREEMENT WITH
THE OWNER.
ENGINEER'S NOTICE TO CONTRACTOR
THE EXISTENCE AND LOCATION OF ANY UNDERGROUND
UTILITY PIPES OR STRUCTURES SHOWN ON THESE DRAWINGS
ARE OBTAINED BY A SEARCH OF THE AVAILABLE RECORDS,
TO THE BEST OF OUR KNOWLEDGE THERE ARE NO EXISTING
UTILITIES EXCEPT AS SHOWN ON THESE DRAWINGS AND WE
ASSUME NO RESPONSIBILITY AS TO THE ACCURACY OF
THEIR DEPICTED LOCATION ON THESE DRAWINGS. THE
CONTRACTOR IS REQUIRED TO TAKE DUE PRECAUTIONARY
MEASURES TO PROTECT THE UTILITY LINES SHOWN, AND
ALL OTHER LINES NOT OF RECORD OR NOT SHOWN ON THESE
DRAWINGS BY VERIFICATION OF THEIR LOCATION IN THE
FIELD PRIOR TO THE INITIATION OF THE ACTUAL PORTION
OF THEIR WORK.
SAFETY NOTICE TO CONTRACTOR
IN ACCORDANCE WITH GENERALLY ACCEPTED CONSTRUCTION
PRACTICES, THE CONTRACTOR WILL BE SOLELY AND
COMPLETELY RESPONSIBLE FOR CONDITIONS OF THE JOB
SITE, INCLUDING SAFETY OF ALL PERSONS AND PROPERTY
DURING PERFORMANCE OF THE WORK. THIS REQUIREMENT
WILL APPLY CONTINUOUSLY AND NOT BE LIMITED TO
NORMAL WORKING HOURS.
THE DUTY OF THE ENGINEER TO CONDUCT CONSTRUCTION
REVIEW OF THE CONTRACTOR'S PERFORMANCE IS NOT
INTENDED TO INCLUDE REVIEW OF THE ADEQUACY OF THE
CONTRACTOR'S SAFETY MEASURES, IN, OR NEAR THE
CONSTRUCTION SITE.
LEGEND (PROPOSED)
SYMBOLS
LINEWORK
•
SET IRON PIN
-------------------
EASEMENT
LIGHT POLE
-
10.
POWER POLE
CURB
■
TELEPHONE PEDESTAL
1208-
0
TV PEDESTAL
INTERMEDIATE CONTOUR
@
MANHOLE
1205-
INDEX CONTOUR
a
SANITARY SEWER CLEANOUT
A
GAS METER
SANITARY SEWER LINE
►t
GAS VALVE
®
STORM SEWER PIPE
GAS LINE
z-x
STRUCTURE NUMBER
_
WATER LINE
►t
WATER VALVE
FIRE HYDRANT ASSEMBLY
UNDERGROUND TELEPHONE
IBI
AIR RELEASE VALVE
m - i
FIRE DEPARTMENT CONNECTION
UNDERGROUND ELECTRIC
•
WATER METER-~
OVERHEAD ELECTRIC
B
BACK FLOW PREVENTER
�
REDUCER
FIBER
PLUG VALVE
UNDERGROUND TELEVISION
❑
GRATED INLET
F
DROP INLET
OVERHEAD TELEVISION
_
CHAIN LINK FENCE
WOOD FENCE
BARBED WIRE FENCE
BUILDING SET BACK
RIGHT OF WAY
PROPERTY LINE
LEGEND
(EXISTING)
OWNERSHIP OF DOCUMENTS
THIS DOCUMENT, AND THE IDEAS AND DESIGNS
SYMBOLS
LIKEWORK
INCORPORATED HEREIN, AS AN INSTRUMENT OF
PROFESSIONAL SERVICES, IS THE PROPERTY OF CRAFTON,
TULL. SPARKS & ASSOCIATES, INC., AND IS NOT TO BE
o
FOUND IRON PIN
EASEMENT
USED, IN WHOLE OR PART, FOR ANY OTHER PROJECT WITH
OUT THE WRITTEN AUTHORIZATION OF CRAFTON, TULL,
-3�_
LIGHT POLE
- _
SPARKS & ASSOCIATES, INC.
1�
POWER POLE
--- -- ------
CURB
m
TELEPHONE PEDESTAL
- - 1206
TV PEDESTAL
INTERMEDIATE CONTOUR
O
MANHOLE
- - 1205 --
INDEX CONTOUR
0
SANITARY SEWER CLEANOUT
_
ZAI
GAS METER
SANITARY SEWER LINE
Da
GAS VALVE
GAS LINE- -
SITE NOTES_
STORM SEWER PIPE
DOWN GUY
&
WATER LINE (SPECIFY SIZE TYPE)
1. ALL WORK AND MATERIALS SHALL COMPLY WITH ALL
CITY/COUNTY/STATE/FEDERAL REGULATIONS AND CODES AND OSHA
D4
WATER VALVE
STANDARDS.
--6-FIRE
HYDRANT ASSEMBLY
UNDERGROUND TELEPHONE
2. CONTRACTOR SHALL REFER TO ARCHITECTURAL PLANS FOR EXACT
AIR RELEASE VALVE
_' i -`
LOCATIONS AND DIMENSIONS OF VESTIBULES, SLOPE PAVING,
UNDERGROUND ELECTRIC
SIDEWALKS, EXIT PORCHES, TRUCK DOCKS, PRECISE BUILDING
FIRE DEPARTMENT CONNECTION
DIMENSIONS AND EXACT UTILITY ENTRANCE LOCATIONS.
O
WATER METER
1-" -T
OVERHEAD ELECTRIC
3. ALL DIMENSIONS AND RADII ARE TO BACK OF CURB UNLESS OTHERWISE
NOTED.
®
SPRINKLER HEAD
--------
4. ALL WORK SHALL BE DONE IN STRICT ACCORDANCE WITH THE PROJECT
®
ELECTRIC PEDESTAL
UNDERGROUND TELEVISION
SPECIFICATIONS.
5. ALL CURB/SIDEWALK/HANDICAP RAMP DESIGNS SHALL CONFORM TO
❑
GRATED INLET
_ _
OVERHEAD TELEVISION
ADA STANDARDS OR LOCAL RESTRICTIVE CODES, WHICHEVER IS MORE
RESTRICTIVE.
6. CONTRACTOR SHALL ENSURE ALL NECESSARY PERMITS ARE OBTAINED
DROP INLET
CHAIN LINK FENCE
PRIOR TO CONSTRUCTION START.
WOOD FENCE
7. CONTRACTOR SHALL MATCH PROPOSED CURB AND GUTTER, CONCRETE,
AND PAVEMENT TO EXISTING IN GRADE AND ALIGNMENT.
TREE
-
8. CONTRACTOR SHALL MAINTAIN ALL EXISTING PARKING, SIDEWALKS,
BARBED WIRE FENCE
DRIVES, ETC. CLEAR AND FREE FROM ANY CONSTRUCTION ACTIVITY
AND/OR MATERIAL TO ENSURE EASY AND SAFE PEDESTRIAN AND
_ _m
FIBER OPTIC
VEHICULAR TRAFFIC TO AND FROM THE SITE.
TREE TO BE REMOVED
RIGHT OF WAY
GENERAL NOTES
1, ENGINEER'S NOTICE TO CONTRACTOR: THE EXISTENCE AND LOCATION OF ANY UNDERGROUND UTILITY PIPES OR
STRUCTURES SHOWN ON THESE DRAWINGS ARE OBTAINED BY A SEARCH OF THE AVAILABLE RECORDS. TO THE
BEST OF OUR KNOWLEDGE THERE ARE NO EXISTING UTILITIES EXCEPT AS SHOWN ON THESE DRAWINGS AND
WE ASSUME NO RESPONSIBILITY AS TO THE ACCURACY OF THEIR DEPICTED LOCATION ON THESE DRAWINGS.
THE CONTRACTOR IS REQUIRED TO TAKE DUE PRECAUTIONARY MEASURES TO PROTECT THE UTILITY LINES
SHOWN, AND ALL OTHER LINES NOT OF RECORD OR NOT SHOWN ON THESE DRAWINGS BY VERIFICATION OF
THEIR LOCATION IN THE FIELD PRIOR TO THE INITIATION OF THE ACTUAL PORTION OF THEIR WORK.
2. SAFETY NOTICE TO CONTRACTOR: IN ACCORDANCE WITH GENERALLY ACCEPTED CONSTRUCTION PRACTICES, THE
CONTRACTOR WILL BE SOLELY AND COMPLETELY RESPONSIBLE FOR CONDITIONS OF THE JOB SITE, INCLUDING
SAFETY OF ALL PERSONS AND PROPERTY DURING PERFORMANCE OF THE WORK. THIS REQUIREMENT WILL
APPLY CONTINUOUSLY AND NOT BE LIMITED TO NORMAL WORKING HOURS. THE DUTY OF THE ENGINEER TO
CONDUCT CONSTRUCTION REVIEW OF THE CONTRACTOR'S PERFORMANCE IS NOT INTENDED TO INCLUDE REVIEW
OF THE ADEQUACY OF THE CONTRACTOR'S SAFETY MEASURES, IN, OR NEAR THE CONSTRUCTION SITE.
3. OWNERSHIP OF DOCUMENTS: THIS DOCUMENT, AND THE IDEAS AND DESIGNS INCORPORATED HEREIN, AS AN
INSTRUMENT OF PROFESSIONAL SERVICES, IS THE PROPERTY OF CRAFTON, TULL, SPARKS & ASSOCIATES, INC.,
AND IS NOT TO BE USED, IN WHOLE OR PART, FOR ANY OTHER PROJECT WITHOUT THE WRITTEN
AUTHORIZATION OF CRAFTON, TULL, SPARKS & ASSOCIATES, INC.
4. CONTRACTOR SHALL NOT CAUSE ANY INCONVENIENCE TO THE PUBLIC, ADJACENT PROPERTY OWNERS,
PEDESTRIANS, ETC. DURING THE CONSTRUCTION OF THIS PROJECT. THE CONTRACTOR SHALL NOT DISRUPT
ACCESS TO ADJACENT PROPERTIES AT ANY TIME DURING CONSTRUCTION.
5. THE CONTRACTOR SHALL CONTACT THE ENGINEER FOR CLARIFICATION IF A DISCREPANCY OR INCONSISTENCY
IS IDENTIFIED ON THE PLANS AND/OR SPECIFICATIONS.
6. CONTRACTOR IS RESPONSIBLE FOR THE DESIGN AND IMPLEMENTATION OF ALL REQUIRED/NECESSARY
SHEETING, SHORING, AND SPECIAL EXCAVATION MEASURES REQUIRED ON THE PROJECT TO MEET OSHA,
FEDERAL, STATE AND LOCAL REGULATIONS.
DRAWINGS, WRITTEN MATERIAL, AND DESIGN CONCEPTS SHALL
NOT BE USED OR REPRODUCED IN WHOLE OR PART IN ANY FORM
WITHOUT PRIOR CONSENT OF ROARK PERKINS PERRY
YELVINGTON ARCHITECTS. DO NOT SCALE DRAWINGS. USE
GIVEN DIMENSIONS ONLY. IF NOT SHOWN, VERIFY DIMENSIONS
WITH THE ARCHITECT. CONTRACTOR SHALL CHECK AND VERIFY
ALL DIMENSIONS AND CONDITIONS AT JOB SITE.
N C?
LLl
� r
®
-a
fr
Q
O
Y
OC
o
zLLJ
zk
w
(/3
>-
z
F-1
0
in
0
w
w
w
crCL0-�-
Q
o
n�
cr
cr
co
TZ
•
i.
Lij
75
m