HomeMy WebLinkAboutZ-8364-C Staff AnalysisFILE NO.: Z-8364-C
NAME: Hilton Garden Inn Short -form PCD
LOCATION: Located at 10914 Kanis Road
DEVELOPER:
Yogiju, Inc.
14 Caddo Court
Maumelle, AR
FNr,INFFR
Grayrock Consulting Company
5204 Village Parkway, Suite #11
Rogers, AR 72758
AREA: 3.728 acres
CURRENT ZONING:
ALLOWED USES:
PROPOSED ZONING
PROPOSED USE
UMBER OF LOTS: 1 FT. NEW STREET: 0 LF
C-3, General Commercial District
General Commercial
PCD
C-3, General Commercial District — Hotel Height
VARIANCES/WAIVERS REQUESTED: None requested.
BACKGROUND:
On May 24, 2010, the Little Rock Zoning Board of Adjustment approved a height
variance for this project. A building height of approximately 52 feet (4-floors) was
approved. The applicant has since obtained a building permit for the hotel project.
On July 30, 2012, the Little Rock Zoning Board of Adjustment denied a request to
amend the previously approved building height variance request. The applicant
determined that an additional floor was needed for the proposed hotel building resulting
in a five (5) story structure. The overall height of the hotel building was proposed at
approximately 61-feet, as measured from the lowest finished floor to the main level
between the eaves and ridge of the sloped roof.
FILE NO.: Z-8364-C (Cont.
0
PROPOSAL/REQUEST/APPLICANT'S STATEMENT:
The applicant is now requesting a rezoning of the site to PCD to allow the five (5)
story hotel. Section 36-301(d) allows a maximum building height of 35-feet for
the C-3, General Commercial Zoning District. The applicant's hotel is proposed
at 61-feet. Section 36-460(f) — Development standards, conditions and review
guidelines for the Planned Zoning Developments, Building height: states there
shall be no maximum building height except as may be determined by the
Planned Commission during the review of the preliminary development plan
based on the uses within the development and the proximity of the development
to existing or prospective development on adjacent properties.
The proposal is to redevelop the property and construct a new hotel facility. The
proposed hotel building will be located within the west half of the property, with
parking on its east and south sides. A driveway at the southwest corner of the
property will serve as access to the site. The hotel will consist of 76,083 square
feet of building area on five (5) floors. There are 135 guest rooms proposed. A
total of 148 parking spaces will be installed.
EXISTING CONDITIONS.
The C-3, General Commercial District zoned property at 10914 Kanis Road
contains a vacant single-family residential structure within the south half of the
property. The property is located on the north side of Kanis Road, approximately
400 feet west of Shackleford Road. A gravel driveway from Kanis Road serves
as access to the property. There is a vacant metal garage structure located on
the north side of the residential structure. Gravel parking is located in the rear
yard area. The majority of the property is undeveloped and wooded. There is a
narrow paved (no curb and gutter) roadway along the west property boundary
which ends near the northwest corner of the property. The property slopes
downward from front to back (south to north). The property is at a lower level
than most of the surrounding properties.
C. NEIGHBORHOOD COMMENTS:
As of this writing, staff has not received any comment from area residents. All
property owners located within 200-feet of the site and the John Barrow
Neighborhood Association were notified of the public hearing.
D. ENGINEERING COMMENTS:
PUBLIC WORKS CONDITIONS:
Dedicate additional access easement on the west side of the property to
30 feet from centerline of the easement along the entire frontage of the
applicant's property.
2
FILE NO.: Z-8364-C (Cont.
2. With site development, provide the design of street within the access
easement conforming to the Master Street Plan. Construct one-half street
improvement to this street including 5-foot sidewalk with the planned
development. The new back of curb should be 15.5-feet from centerline.
At least 20-feet of pavement must be provided.
3. The street within the access easement must intersect Kanis Road at a
90 degree angle.
4. Kanis Road is classified on the Master Street Plan as a minor arterial.
A dedication of right-of-way 45 feet from centerline will be required.
5. With site development, provide the design of street conforming to the
Master Street Plan. Construct one-half street improvement to Kanis Road
including 5-foot sidewalk with the planned development. The new back of
curb should be placed 29.5-feet from centerline.
6. A grading permit in accordance with Section 29-186 (c) and (d) will be
required prior to any land clearing or grading activities at the site. Other
than residential subdivisions, site grading and drainage plans must be
submitted and approved prior to the start of construction.
7. Provide a Sketch Grading and Drainage Plan as required by Section
29-186(e).
8. Stormwater detention ordinance applies to this property. Show the
proposed location for stormwater detention facilities on the plan.
9. Plans of all work in right-of-way shall be submitted for approval prior to start
of work. Obtain barricade permit prior to doing any work in the right-of-way
from Traffic Engineering at (501) 379-1805 (Travis Hebner).
10. Driveway locations and widths do not meet the traffic access and circulation
requirements of Sections 30-43 and 31-210. The width of the driveway
must not exceed 36-feet.
11. If disturbed area is one (1) or more acres, obtain a NPDES stormwater
permit from the Arkansas Department of Environmental Quality prior to the
start of construction.
12. All driveways shall be concrete aprons per City Ordinance.
13. Street Improvement plans shall include signage and striping. Traffic
Engineering must approve completed plans prior to construction.
14. On site striping and signage plans should be forwarded to Public Works,
Traffic Engineering for approval with the site development package.
15. Streetlights are required by Section 31-403 of the Little Rock code. Provide
plans for approval to Traffic Engineering. Streetlights must be installed
along the access easement and Kanis Road prior to platting/certificate of
occupancy. Contact Traffic Engineering 379-1813 for additional
information.
3
FILE NO.: Z-8364-C (Cont.
16. Street names and street naming conventions for the street within the access
easement must be approved by Public Works. Contact David Hathcock at
371-4808.
17. Vegetation must be established on disturbed area within 21 days of
completion of harvest activities.
18. Erosion controls must be installed to reduce discharge of polluted
stormwater.
19. Provide a letter prepared by a registered engineer certifying the sight
distance at the intersections comply with 2004 AASHTO Green Book
standard.
E. UTILITIES AND FIRE DEPARTMENT/COUNTY PLANNING:
Wastewater: Sewer available to this project. Capacity contribution analysis and
fee required prior to connection to Little Rock Wastewater System. Contact Little
Rock Wastewater for additional details and information.
Entergy: No comment received.
Center -Point Enerav: No comment received.
AT & T: No comment received.
Central Arkansas Water: All Central Arkansas Water requirements in effect at
the time of request for water service must be met. A water main extension will be
needed to provide water service to this property. This development will have
minor impact on the existing water distribution system. Proposed water facilities
will be sized to provide adequate pressure and fire protection. The Little Rock
Fire Department needs to evaluate this site. to determine whether additional
public and/or private fire hydrant(s) will be required. If additional fire hydrant(s)
are required, they will be installed at the Developer's expense. Please submit
plans for water facilities and/or fire protection system to Central Arkansas Water
for review. Plan revisions may be required after additional review. Contact
Central Arkansas Water regarding procedures for installation of water facilities
and/or fire service. Approval of plans by the Arkansas Department of Health
Engineering Division and the Little Rock Fire Department is required. Contact
Central Arkansas Water regarding the size and location of the water meter. A
Capital Investment Charge based on the size of meter connection(s) will apply to
this project in addition to normal charges. This fee will apply to all connections
including metered connections off the private fire system. If there are facilities
that need to be adjusted and/or relocated, contact Central Arkansas Water. That
work would be done at the expense of the developer. Due to the nature of the
facility, installation of an approved reduced pressure zone backflow preventer
assembly (RPZ) is required on the domestic water service. This assembly must
be installed prior to the first point of use. Central Arkansas Water (CAW)
required that upon installation of the RPZA, successful tests of the assembly
4
FILE NO.: Z-8364-C (Cont.
must be completed by a Certified Assembly Tester licensed by the State of
Arkansas and approved by Central Arkansas Water. The test results must be
sent to Central Arkansas Water's Cross Connection Section within ten days of
installation and annually thereafter. Contact the Cross Connection Section at
377-1226 if you would like to discuss backflow prevention requirements for the
project. The facilities on site will be private. When meters are planned off private
lines, private facilities shall be installed to Central Arkansas Water's material and
construction specifications and installation will be inspected by an engineer,
licensed to practice in the State of Arkansas. Execution of Customer Owned
Line Agreement is required.
Fire Department: Place fire hydrants per code. Maintain a minimum access of at
least 20-feet. Contact the Little Rock Fire Department for additional information.
County Planning: No comment.
CATA: The site is located near CATA Bus Route #3 — the Baptist Medical Center
Route.
Parks and Recreation: No comment received.
F. ISSUES/TECHNICAL/DESIGN:
Planning Division: This request is located in the 1-430 Planning District. The
Land Use Plan shows Commercial (C) for this property. The Commercial
category includes a broad range of retail and wholesale sales of products,
personal and professional services, and general business activities. Commercial
activities vary in type and scale, depending on the trade area that they serve.
The applicant has applied for a rezoning from C-3, General Commercial District
to PCD (Planned Commercial District) to allow a hotel to be constructed at a
greater height than that allowed in the C-3, General Commercial Zoning District.
Master Street Plan: Kanis Road is a Minor Arterial on the Master Street Plan.
A Minor Arterial provides connections to and through an urban area and their
primary function is to provide short distance travel within the urbanized area.
Entrances and exits should be limited to minimize negative effects of traffic and
pedestrians on Kanis Road since it is a Minor Arterial. This street may require
dedication of right-of-way and may require street improvements for entrances
and exits to the site.
Bic cle Plan: There are no bike routes shown in the immediate vicinity of the
application.
Landscape:
1. Site plan must comply with the City's landscape and buffer ordinance
requirements.
5
FILE NO.: Z-8364-C (Cont.
2. The landscape ordinance requires a minimum of eight percent (8%) of the
paved areas be landscaped with interior islands of at least 7 % feet in width
and 150 square feet in area. The islands must be evenly distributed
throughout the site.
3. A controlled automatic irrigation system is required.
4. Prior to the issuance of a building permit, it will be necessary to provide
landscape plans stamped with the seal of a Registered Landscape Architect.
5. The City Beautiful Commission recommends preserving as many existing
trees as feasible on this site. Credit toward fulfilling Landscape Ordinance
requirements can be given when preserving trees of six (6) inch caliper or
larger.
G. SUBDIVISION COMMITTEE COMMENT: (August 22, 2012)
The applicant was present. Staff presented an overview of the development
stating there were few outstanding technical issues associated with the request.
Staff stated the plan was three (3) parking spaces short and they felt the plan
could be revised to include the additional parking. Staff also questioned the
proposed signage plan including ground and building signage. Staff questioned
if there would be a bar and/or restaurant within the building. Staff also
questioned the location of the dumpster facility.
Public Works comments were addressed. Staff stated a dedication of additional
area for the access easement along the western property line was required.
Staff also stated the driveway was to intersect Kanis Road at a 90 degree angle.
Staff stated the stormwater detention ordinance would apply to the development
of the site. Staff also requested the applicant provide a sketch grading and
drainage plan.
Landscaping comments were addressed. Staff stated a minimum of eight
percent (8%) of the paved areas were to be landscaped with landscape islands.
Staff also stated automatic irrigation was required to water landscaped areas.
Staff noted a landscape plan stamped with the seal of a registered landscape
architect was required at the time of building permit.
Staff noted comments from the other reporting departments and agencies
suggesting the applicant contact them individually for additional clarification.
There was no further discussion of the item. The Committee then forwarded the
item to the full Commission for final action.
H. ANALYSIS:
The applicant submitted a revised site plan to staff addressing the comments
raised at the August 22, 2012, Subdivision Committee meeting. The revised plan
has included the four (4) additional parking spaces required to meet the typical
minimum ordinance requirements. The site plan also includes the placement of a
A
FILE NO.: Z-8364-C (Cont.)
ground sign within the front yard setback and provided the building signage plan.
The driveway has been redesigned to intersect Kanis Road at a 90 degree angel.
The applicant has also indicated the western access easement will be
constructed as requested by Public Works staff or if all property owners agree
proper procedures for abandonment of the easement will be initiated.
The site plan indicates the placement of a pole sign with a maximum height of
36-feet and a maximum sign area of 160 square feet. Building signage will be
placed on the Kanis Road side of the building and on the eastern facade, the
front of the building. The signage will be limited to a maximum of ten (10)
percent of the facade area on which the signage is place.
Parking for a hotel development is based on one parking space per guest room
plus an additional ten (10) percent of the total of all parking spaces is required for
developments larger than twenty (20) rooms for employees and non guest users
patronizing meeting rooms, restaurants and other facilities. The hotel is
proposed with 135 guest rooms which would require a total of 148 parking
spaces. The site plan as presented provides the 148 parking spaces. The hotel
is proposed with restaurant and bar service. There are also areas for meeting
space within the proposed hotel.
The hotel is proposed as a five story structure with a maximum height of 61 feet.
The property is presently zoned C-3, General Commercial District which typically
allows a maximum building height of 35-feet.
Staff is supportive of the requested PCD zoning. There are two (2) issues which
do not meet the typical development standards of the zoning ordinance. One is
the building height and the second signage on the eastern facade of the hotel
building which is located without public street frontage. Staff does not feel the
proposed building height for the hotel structure will be out of character with other
sites in the general area along the Shackleford Road corridor, from Financial
Center Parkway south to Interstate 430. There are numerous buildings within
this general area with heights of four (4) and five (5) stories or greater. The
property immediately to the north is zoned 0-3, General Office District with
building heights allowed up to 60-feet. The undeveloped property to the west is
zoned C-2, Shopping Center District which allows building heights up to 45-feet.
Additionally, the project basically sits at a lower elevation than most of the
surrounding properties, especially to the east and south. The height of the
building is measured from the lowest finished floor to the main level between the
eaves and ridge of the sloped roof.
Staff also is supportive of allowing signage without public street frontage along
the eastern, front facade of the proposed hotel. The applicant has indicated the
sign will comply with signage typically allowed in commercial zones or a
maximum of ten (10) percent of the facade area. Signage will also be placed
along the facade fronting Kanis Road also limited to a maximum of ten (10)
percent of the facade area of the building.
7
FILE NO.: Z-8364-C (Cont.
Staff believes the proposed hotel building and the signage as proposed will be
compatible with other existing buildings in this general area, and that the overall
hotel development will have no adverse impact on the adjacent properties or the
general area.
I. STAFF RECOMMENDATION:
Staff recommends approval of the request subject to compliance with the
comments and conditions as outlined in paragraphs D, E and F of the agenda
staff report.
PLANNING COMMISSION ACTION:
The applicant was present. There were
presented the item with a recommendation
compliance with the following:
(SEPTEMBER 13, 2012)
no registered objectors present. Staff
of approval of the request subject to
1. Compliance with the comments and conditions as outlined in paragraphs D, E
and F of the agenda staff report.
2. Per the Master Street Plan, sidewalk is required to be installed along the east
side of the access easement adjacent to the subject property.
3. The proposed paving surfaces at the private street/driveway area will be required
to be modified at the time of the building permit application.
4. The configuration of the transition of the private street and the driveway will be
required to be slightly modified at the time of the building permit application.
There was no further discussion of the item. The Chair entertained a motion for
approval of the item on the Consent Agenda as presented by staff. The motion carried
by a vote of 10 ayes, 0 noes and 1 absent.
P
ITEM NO.: 16.
NAME: Hilton Garden Inn Short -form PCD
LOCATION: located at 1094 Kanis Road
Plannina Staff Comments:
Z-8364-C
1. Provide notification of property owners located within 200-feet of the site including
the certified abstract list, notice form with affidavit executed and proof of mailing.
The notice must be mailed no later than August 28, 2012. The Office of Planning
and Development must receive the proof of notice no later than September 7, 2012.
2. The site plan indicates a total of 145 parking spaces provided. The zoning
ordinance would typically require the placement of 148 parking spaces to serve the
number of rooms proposed. Staff feels the three additional spaces can be obtained
by revising the site plan along the southeastern portion of the site and adding three
spaces to the existing four spaces.
3. Provide details of the proposed signage plan including ground and building signage.
Provide the location of the proposed ground signage and provide the total height and
total sign area. Provide the facades proposed for building signage and include the
percentage of fagade area proposed with signage.
4. Will there be a bar/restaurant or meeting space at the hotel? If so provide details of
the proposed services.
5. Provide the location of the proposed dumpster facility along with a note concerning
the required screening.
6. All site lighting is to be low level and directional, directed downward and into the site.
7. Provide a note on the site plan indicating the maximum building height proposed for
the structure. The site plan indicates 5 stories but does not indicate the building
height.
8. Where will the mechanical equipment be located? If located on the ground provide
a note concerning the required screening.
Variance/Waivers: None requested.
Public Works Conditions:
1. Dedication additional access easement on the west side of the property to 30 feet
from centerline of the easement along the entire frontage of the applicant's property.
2. With site development, provide the design of street within the access easement
conforming to the Master Street Plan. Construct one-half street improvement to this
street including 5-foot sidewalk with the planned development. The new back of
curb should be 15.5-feet from centerline. At least 20-feet of pavement must be
provided.
3. The street within the access easement must intersect Kanis Road at a 90 degree
angle.
4. Kanis Road is classified on the Master Street Plan as a minor arterial. A dedication
of right-of-way 45 feet from centerline will be required.
Item # 16.
5. With site development, provide the design of street conforming to the Master Street
Plan. Construct one-half street improvement to Kanis Road including 5-foot
sidewalk with the planned development. The new back of curb should be placed
29.5-feet from centerline.
6. A grading permit in accordance with Section 29-186 (c) and (d) will be required prior
to any land clearing or grading activities at the site. Other than residential
subdivisions, site grading and drainage plans must be submitted and approved prior
to the start of construction.
7. Provide a Sketch Grading and Drainage Plan as required by Section 29-186(e).
8. Stormwater detention ordinance applies to this property. Show the proposed
location for stormwater detention facilities on the plan.
9. Plans of all work in right-of-way shall be submitted for approval prior to start of work.
Obtain barricade permit prior to doing any work in the right-of-way from Traffic
Engineering at (501) 379-1805 (Travis Hebner).
10. Driveway locations and widths do not meet the traffic access and circulation
requirements of Sections 30-43 and 31-210. The width of the driveway must not
exceed 36-feet.
11. If disturbed area is one (1) or more acres, obtain a NPDES stormwater permit from
the Arkansas Department of Environmental Quality prior to the start of construction.
12.All driveways shall be concrete aprons per City Ordinance.
13. Street Improvement plans shall include signage and striping. Traffic Engineering
must approve completed plans prior to construction.
14.On site striping and signage plans should be forwarded to Public Works, Traffic
Engineering for approval with the site development package.
15. Streetlights are required by Section 31-403 of the Little Rock code. Provide plans
for approval to Traffic Engineering. Streetlights must be installed along the access
easement and Kanis Road prior to platting/certificate of occupancy. Contact Traffic
Engineering 379-1813 for additional information.
16. Street names and street naming conventions for the street within the access
easement must be approved by Public Works. Contact David Hathcock at 371-
4808.
17.Vegetation must be established on disturbed area within 21 days of completion of
harvest activities.
18. Erosion controls must be installed to reduce discharge of polluted stormwater.
19. Provide a letter prepared by a registered engineer certifying the sight distance at the
intersections comply with 2004 AASHTO Green Book standard.
Utilities and Fire Department/County Planning:
Wastewater: Sewer available to this project. Capacity contribution analysis and fee
required prior to connection to Little Rock Wastewater System. Contact Little Rock
Wastewater for additional details and information.
Entergy: No comment received.
Center -Point Energy: No comment received.
AT & T: No comment received.
Item # 16.
Central Arkansas Water: All Central Arkansas Water requirements in effect at the time
of request for water service must be met. A water main extension will be needed to
provide water service to this property. This development will have minor impact on the
existing water distribution system. Proposed water facilities will be sized to provide
adequate pressure and fire protection. The Little Rock Fire Department needs to
evaluate this site to determine whether additional public and/or private fire hydrant(s)
will be required. If additional fire hydrant(s) are required, they will be installed at the
Developer's expense. Please submit plans for water facilities and/or fire protection
system to Central Arkansas Water for review. Plan revisions may be required after
additional review. Contact Central Arkansas Water regarding procedures for installation
of water facilities and/or fire service. Approval of plans by the Arkansas Department of
Health Engineering Division and the Little Rock Fire Department is required. Contact
Central Arkansas Water regarding the size and location of the water meter. A Capital
Investment Charge based on the size of meter connection(s) will apply to this project in
addition to normal charges. This fee will apply to all connections including metered
connections off the private fire system. If there are facilities that need to be adjusted
and/or relocated, contact Central Arkansas Water. That work would be done at the
expense of the developer. Due to the nature of the facility, installation of an approved
reduced pressure zone backflow preventer assembly (RPZ) is required on the domestic
water service. This assembly must be installed prior to the first point of use. Central
Arkansas Water (CAW) required that upon installation of the RPZA, successful tests of
the assembly must be completed by a Certified Assembly Tester licensed by the State
of Arkansas and approved by Central Arkansas Water. The test results must be sent to
Central Arkansas Water's Cross Connection Section within ten days of installation and
annually thereafter. Contact the Cross Connection Section at 377-1226 if you would
like to discuss backflow prevention requirements for the project. The facilities on site
will be private. When meters are planned off private lines, private facilities shall be
installed to Central Arkansas Water's material and construction specifications and
installation will be inspected by an engineer, licensed to practice in the State of
Arkansas. Execution of Customer Owned Line Agreement is required.
Fire Department: Place fire hydrants per code. Maintain a minimum access of at
least 20-feet. Contact the Little Rock Fire Department for additional information.
County Planning: No comment.
CATA: The site is located near CATA Bus Route #3 — the Baptist Medical Center
Route.
Parks and Recreation: No comment received.
Planning Division: This request is located in the 1-430 Planning District. The Land Use
Plan shows Commercial (C) for this property. The Commercial category includes a
broad range of retail and wholesale sales of products, personal and professional
services, and general business activities. Commercial activities vary in type and scale,
depending on the trade area that they serve. The applicant has applied for a rezoning
from C-3, General Commercial District to PCD (Planned Commercial District) to allow a
hotel to be constructed at a greater height than that allowed in the C-3, General
Commercial Zoning District.
Item # 16.
Master Street Plan: Kanis Road is a Minor Arterial on the Master Street Plan. A Minor
Arterial provides connections to and through an urban area and their primary function is
to provide short distance travel within the urbanized area. Entrances and exits should
be limited to minimize negative effects of traffic and pedestrians on Kanis Road since it
is a Minor Arterial. This street may require dedication of right-of-way and may require
street improvements for entrances and exits to the site.
Bicycle Plan: There are no bike routes shown in the immediate vicinity of the
application.
Landscape:
1. All previous comments apply.
2. Site plan must comply with the City's landscape and buffer ordinance requirements.
3. The landscape ordinance requires a minimum of eight percent (8%) of the paved
areas be landscaped with interior islands of at least 7 % feet in width and 150 square
feet in area. The islands must be evenly distributed throughout the site.
4. A controlled automatic irrigation system is required.
5. Prior to the issuance of a building permit, it will be necessary to provide landscape
plans stamped with the seal of a Registered Landscape Architect.
6. The City Beautiful Commission recommends preserving as many existing trees as
feasible on this site. Credit toward fulfilling Landscape Ordinance requirements can
be given when preserving trees of six (6) inch caliper or larger.
Revised plat/plan: Submit four (4) copies of a revised preliminary plat/plan (to include
the additional information as noted above) to staff on Wednesday, August 29, 2012.
Item # 16.