HomeMy WebLinkAboutZ-8359 Map 36d
r
0
0
91
.6
63
L
o�
a ¢
d
o 0
-¢>
T az
;
® rn
8�
-J
9
LU
Im
wm
®m
IM H
�p 22
I
\ PROPOSED DUMPSTER -
W/6' WOOD ENCLMRE
_ PROPOSED
�r eX/SrINET. RETAINING
G WALL G24„XINLET
53148OP513TEF3O
NW1/4 SE1,4
3.74 ACRES
TRACT C-R
S
EX. INLET--61-
TOP: 536.44
'F: 524.70
PROPOSED CURB CANTRELL HEIGHTS
ak OTTER (TYP) COMMERCIAL SUB.
-I PROPOSED HC
® SIGN
PROPOSED HC
j SPACE
PROPOSED CURB (t12
(TYP GUSNG�s HOLE RIM
)
h
i
I
w l '
t,
f
z
QI0
\ J �,W-
EXISTING POWER POLE TO BE J
RELOCATED. COORDINATE EX.
W/ELECTRIC PROVIDER. TOP:
'F: 5,
lR?
,s \
s
s
O��ps
PROPOSED
CONCRETE DIG(
(TYP) (SEE f 25,5D0 SQ.FT. STORE FRONT LEVEL
ARCH. PLANWIEND EXISTING
MATCH EXISTING
CURB
\ \ PROPOSED CURB
& GUTTER (TYP)
IN ET \ \ 0f
42. 8 \ \\ \
t .
SF\
liy�\ c�8 -;0\\ 20 9��
PEA
ADJUST STING \off oG
\ }{
MOLE
E) SS
PROPOSED CK T P:5 5.5
:5 .31 00
` . EX. I
Cal PROPOSED P:5 25
BOLLARD �; 41. r ��
(40..C.)
ADJUST EXISTING R2
MANHOLE RIM
EX INLE
546. \ \
T:
Z i UEANOUTS TO 52 STORE FRONT PARKING 4•PACFS
\ \ j iKOPOSED GRADE 62 REAR AND EMPLOYEE SPACES TOP: 546.88 ' X. W ! \`\
() COA4M�CFAL 8L06 114 TOTAL PARKING SPACES EXTEND EXISTING ii q<< �yd
\ 4.47/1 IN CLEANOUiS TO
PROPOSED GRADE M/1(CH EXISTING \`. \\"k,
PROPOSED HC 3 HANDICAP SPACES REQUIRED (TYP) A HALT
TRACT A-R \\
RAMP 5 HANDICAP SPACES PROVIDED n
_ PROPOSED HC
EVS7NG SIGN
' - �ANCRETE SIDEWALK OPOSED HC PATIO DINING I\ \\\ \
SP AREA (SEE ;It
CH. PLANS) ;;l� EXISTING
N j -ROROSED —� a E"W COMBLDGCIAL F\ \ram \
\ RIGHT-OF-WAY - 9' _ \
DEIICATION �_ II \ \\
218.4¢ EXISTING `" sr• 1 3 it
It
�'"'� HYDRANT
30' �o P x I n� \
- �3H0 �_ 9Q - %a`r PROPOSED 40 BUIEfING-ME-- i — 1� \ \�
= o ZED SIGN Sd,EX- INLET. — —``� \\
RB
-=FX C� LINf ` ASTI G WATER PROPOSED CURB �l :TOP 555.S zze
-- N ETE S g GUTS F: 553.01 `MATCH EXISTING
_ j
s WASPHALT ,
EX TIN EXISTING
- 5
S#N A OHE��•_��
^-� • a.,_ M I ASPH. PARKING AREA
- AH1D DR-1
r 60 �- Id) E
0
30'
i
zu...• 11' --CONCRETE ON Wr -
m. CA AHTD TYPE A CURB 5 CONCRETE SI E Y —
_ N ._.. �. 0
,
ROA� _.. MATCH EXISTING F=
(RIGHT -OF- --ASPHALT a-,
__ R! WAY E _ _.r _...__ _.____ —
�ARi S a. _ W s W
AHTD DR-1 S 89162202, 8 `I2'72'
w CONCRETE APRON MATCH EXISTING 16.00'
NCiPgL AhjER CURB & SIDEWALK
0
e1 s
�. 400, 3
10
t
S
rT; < �
aM
�ET
ON
i� AVM
s
02FFgA, <V
"'n SOME MN[ MI
ar
{ Lo
IAL®-- ��.�..sSST
EXISTING wa-
bbb STRIPING
Silt NUILh
u 1. ALL WORK AND MATERIALS MALL COMPLY WITH ALL 5. ALL CURB/SIDEWALK/HANDICAP RAMP DESIGNS SHALL CONFORM TO ADA
o CITY/COUNTY/STATE/FEDERAL REGULATIONS AND CODES AND OSHA STANDARDS OR LOCAL RESTRICTIVE CODES, WHICHEVER IS MORE
a RESTRICTIVE.
STANDARDS .
2. CONTRACTOR SHALL REFER TO ARCHITECTURAL PLANS FOR EXACT 6. CONTRACTOR SHALL ENSURE ALL NECESSARY PERMITS ARE OBTAINED
o LOCATIONS AND DIMENSIONS OF VESTIBULES, SLOPE PAVING, SIDEWALKS, PRIOR TO CONSTRUCTION START.
EXIT PORCHES, TRUCK DOCKS, PRECISE BUILDING DIMENSIONS AMD EXACT 7. CONTRACTOR SHALL MATCH PROPOSED CURB AND GUTTER, CONCRETE,
ALIGNMENT.
- N GRADE AND LIGN
AND PAVEMENT
TO EXISTING 1
CE LOCATIONS.
A
�- UTILITY ENTRANCE
0 3. ALL DIMENSIONS AND RADII ARE TO BACK OF CURB UNLESS 0111ERMSE 8. CONTRACTOR SHALL MAINTAIN ALL EXISTING PARKING, SIDf:WALKS,
NOTED. DRIVES, ETC. CLEAR AND FREE FROM ANY CONSTRUCTION ACTIVITY
4. ALL WORK SHALL BE DONE IN STRICT ACCORDANCE WITH THE PROJECT AND/OR MATERIAL TO ENSURE EASY AND SAFE PEDESTRIAN AND
SPECIFICATIONS. VEHICULAR TRAFFIC TO AND FROM THE SITE.
OWNERSHIP OF DOCUMENTS
THIS DOCUMENT, AND THE IDEAS AND DESIGNS
INCORPORATED HEREIN, AS AN INSTRUMENT OF
PROFESSIONAL SERVICES, IS THE PROPERTY OF CRAFTON.
TUU- SPARKS & ASSOCIATES, INC., AND IS NOT TO BE
USED, IN WHOLE OR PART, FOR ANY OTHER PROJECT WITH
OUT THE WRITTEN AUTHORIZATION OF CRAFTON, TULL.
SPARKS & ASSOCIATES, INC.
VICINITY MAP
NTS
e,
ENGINEER'S NOTICE TO CONTRACTOR
THE EXISTENCE AND LOCATION OF ANY UNDERGROUND
UTILITY PIPES OR STRUCTURES SHOWN ON THESE DRAWINGS
ARE OBTAINED BY A SEARCH OF THE AVAILABLE RECORDS.
TO THE BEST OF OUR KNOWLEDGE THERE ARE NO EXISTING
UTILITIES EXCEPT AS SHOWN ON THESE DRAWINGS AND WE
ASSUME NO RESPONSIBILITY AS TO THE ACCURACY OF
THEIR DEPICTED LOCATION ON THESE DRAWINGS. THE
CONTRACTOR IS REQUIRED TO TAKE DUE PRECAUTIONARY
MEASURES TO PROTECT THE UTILITY LINES SHOWN, AND
ALL OTHER LINES NOT OF RECORD OR NOT SHOWN ON THESE
DRAWINGS BY VERIFICATION OF THEIR LOCATION IN THE
FIELD PRIOR TO THE INITIATION OF THE ACTUAL PORTION
OF THEIR WORK.
SAFETY NOTICE TO CONTRACTOR
IN ACCORDANCE WITH GENERALLY ACCEPTED CONSTRUCTION
PRACTICES, THE CONTRACTOR WILL BE SOLELY AND
COMPLETELY RESPONSIBLE FOR CONDITIONS OF THE JOB
SITE, INCLUDING SAFETY OF ALL PERSONS AND PROPERTY
DURING PERFORMANCE OF THE WORK. THIS REQUIREMENT
T BE LIMITED TO
WILL APPLY CONTINUOUSLY AND NOT
NORMAL WORKING HOURS.
THE DUTY OF THE ENGINEER TO CONDUCT CONSTRUCTION
REVIEW OF THE CONTRACTOR'S PERFORMANCE IS NOT
INTENDED TO INCLUDE REVIEW OF THE ADEQUACY OF THE
CONTRACTOR'S SAFETY MEASURES, IN, OR NEAR THE
CONSTRUCTION SITE. -
GRAPHIC SCALE IN FEET
30' 0 30'
--1206
�. .- 1205-- --. r
— SS
-- SS
G
G
—W—
W
UGT —
UGT
UGE —
UGE
FO
OHE
ONE
UGTV
OHTV
OHTV
FOUND IRON PIN
SET IRON PIN
EXISTING LIGHT POLE
EXISTING POWER POLE
PROPOSED POWER POLE
EXISTING TELEPHONE PEDESTAL
PROPOSED TELEPHONE PEDESTAL
EXISTING ELECTRIC PEDESTAL
EXISTING WATER VALVE
PROPOSED WATER VALVE
EXISTING FIRE HYDRANT ASSEMBLY
PROPOSED FIRE HYDRANT ASSEMBLY
EXISTING WATER METER
PROPOSED WATER METER
EXISTING MANHOLE
PROPOSED MANHOLE
EXISTING GAS METER
PROPOSED GAS METER
EXISTING GRATED INLET
PROPOSED GRATED INLET
EXISTING DROP INLET
PROPOSED DROP INLET
PROPOSED STORM STRUCTURE NUMBER
DOWN GUY
EXISTING REINFORCED CONCRETE PIPE
OR CORRUGATED METAL PIPE
NEW REINFORCED CONCRETE PIPE
OR CORRUGATED METAL PIPE
EXISTING CURB
EXISTING INTERMEDIATE CONTOUR
EXISTING INDEX CONTOUR
PROPOSED INTERMEDIATE CONTOUR
PROPOSED INDEX CONTOUR
PROPOSED CURB
EXISTING SANITARY SEWER LINE
PROPOSED SANITARY SEWER LINE
EXISTING GAS LINE
PROPOSED GAS LINE
EXISTING WATER LINE
PROPOSED WATER LINE
EXISTING UNDERGROUND TELEPHONE
PROPOSED UNDERGROUND TELEPHONE
EXISTING UNDERGROUND ELECTRIC
PROPOSED UNDERGROUND ELECTRIC
EXISTING FIBER OPTIC
EXISTING OVERHEAD ELECTRIC
PROPOSED OVERHEAD ELECTRIC
EXISTING UNDERGROUND TELEVISION
PROPOSED UNDERGROUND TELEVISION
EXISTING OVERHEAD TELEVISION
PROPOSED OVERHEAD TELEVISION
EXISTING WOOD FENCE
PROPOSED WOOD FENCE
EXISTING BARBED WIRE FENCE
PROPOSED BARBED WIRE FENCE
EXISTING CHAIN LINK FENCE
PROPOSED CHAIN LINK FENCE
PROPERTY LINE
BUILDING SET BACK
EXISTING EASEMENT
PROPOSED EASEMENT
EXISTING RIGHT OF WAY
PROPOSED RIGHT OF WAY
EXISTING TREE
TREE TO BE REMOVED
NOTIFICATION OF LIMITED SERVICES
CRAFTON, TULL, SPARKS & ASSOCIATES, INC., (CTSA) HAS
NOT BEEN RETAINED BY THE OWNER FOR CONSTRUCTION
ADMINISTRATION OR OBSERVATION SERVICES ON ALL OR A
PORTION OF THE WORK INDICATED ON THESE DRAWINGS.
THERE70RE, THE CTSA HEREBY NOTIFIES ALL PARTIES
ASSUMES NO RESPONSIBILITY FOR
INVOLIED THAT THE CTSA SSU
THE INTERPRETATION, COORDINATION AND ADMINISTRATION OF
THESE DOCUMENTS AND/OR DEVIATIONS THEREFROM AND THE
EFFECTS THOSE CHANGES MAY HAVE ON ANY AND ALL
RELATED TRADES OR CONSTRUCTION SEQUENCES, OR
OPERATION OF THE COMPLETED PROJECT, EXCEPT AS SPEC-
IFICALLY REQUIRED IN THE CTSA's SERVICES AGREEMENT WITH
THE OWNER.
=CAP ®9J•i
CP,AROKUL
SPAM& A
ASS0CVZ,NC.
y N0.iW
4NSAS EN�+`NEF.e.
T ARK"AS
REGISTERED
PROFESSIONAL
ENGINEER
✓ No. 9407
`CRY J.
to
to he
LLJ
Z
LU
Z
0
y
Z
®
Q
Z
q-
CL
W
O
>
IY
j
=COQ0
CD
Z
C
v=
Uj
Y
O
J
�f
J
ONO
LU
CL
J
W
F-
M
Revisions
SITE PLAN
Drawn by
BAP
Checked by
1, >
05/23/08
Job Number
088010-00
Contact Person
J.KELSO
Sheet Number
S
p 1.0
7 d5� /