HomeMy WebLinkAboutZ-8359 Map 2I
0
v
0
m
I
\ I
S3,
\
\ i
\I PROPOSED DUMPSTER
\ I W/6' WOOD ENCLOSURE
PROPOSED
3' RETAINING WALL
I EX. INLET fX�Sr/_NG 24"
TOP: 531.48 _CMp
I F.513.36 PART OFTHI
NW1/4 SEt/4
3.74 ACRES
I KFR UN� TRACT C—R
SS
I EX. INLET�-
TOP: 536.44
'F: 524.70
PR I Aern CURB CANTRELL HEIGHTS
& ITTER (TYP) COMMERCIAL SUB.
I • O PROPOSED HC
i SIGN
I PROPOSED HC
SPACE
PROPOSED CURB
C & GUTTER (TYP)i o
ADJUST EXISTING
HOLE RIM ti
EXISTING POWER POLE TO BE -J �� ��
RELOCATED. COORIDINATE EX. Mli y
W/ELECTRIC PROVIDER. TOP:
'F: 543.57
PROPOSED
CONCRETE DOCK
(TYP) (SEE '
ARCH. PLANOTEND EXISTING
CLEANOUTS TO
PROPOSE) GRADE EXIS 1NG
() COMMERCIAL BLDG
'C.01a1 .0,,
RAMP
PROPOSED HC
EXISTING C SIGN
_ _ONCRETE SIDEWALK
IT
P' —PROPOSED _1i
RIGHT—OF—WAY _ 9'
p� DEIICATIONTION —'—�
N
218,44• EXISTING
-` HYDRANT
EX. CC1 L-N-�-
MATCH EXISTING
\ CURB
W\ \
\ \ PROPOSED CURB
\ & GUTTER (TYP)
E . IN ET
OP: 42. 8 \
SSM zi\ \ 9Q
\\\ o
9 N /ST�'C 5 \ ,per \
vs
r
ST STING �o� �Z-
MAN OLE \ vc v
E) SS
PROPOSED ECK T P:5 5.5
p r :53.31 EX. I
-PROPOSED P:5 25 �A
BOLLARD 41. '0
XIS 40..C.)
\
E ADJUST EXISTING 112'i
MANHOLE RIM
zll \ l F \
t 25,500 SQ.FT. STORE FRONT LEVEL - 4n' EX. INLE ` \ A
• 546.
52 STORE FRONT PARKING SPACES X. SSM 'F:5
62 REAR AND EMPLOYEE SPACES TOP: 546.88 n Fx W (( \ \ \
114 TOTAL PARKING SPACES TEND ISTI G
/
4.47 WOOD PROPOSED GRADE Mg7CH EXISTING
3 HANDICAP SPACES REQUIRED (TYP) A HALT ` \
5 HANDICAP SPACES PROVIDED TRACT A—P,
ROPOSED HC 7ZPATIO DINING (
SPA AREA (SEE z \ \\ \
RCH. PLANS) °� EXISTING \\
W COMBER CIA- �\ \
u 2`�
xPROPOSED 40 BUTDING-CTNE— " �
SIGN �5 1 Q EX. INLET
I ASTI G WATER PROPOSED CURB `CR \ TOP: 555.32
ETE S & GUTTER �F:553:01 MATCH EXISTING \ I \
_ EX STIN �y ASPHALT \�\
M I EXISTING \ \
A OHE �� ASPH. PARKING AREA
AHTD DR-1 RS o - _ C) 30'
fJ E
60.11' CONCRETE APRON ' — — _ PRH9Pp p 5 CONCRETE SIDE A E7 I� l
CANT%RfL -AHTD TYPE A CURB 1. ° r 0 t—
ROAD MATCH EXISTING ---- -_ --_-- = - -- EXI�T1f1G�8 f4C ° Il
(RI GH j_ OF— ASPHALT-- — — _ _ 4-1
2;
---—----�—
_ _- - PRI WAY VARIES _- AHTD DR-1 S H12'12 W S ss12'12' W
_ - NC/P - _ EXISTING 16.20 16.00'
A� ARTERI CONCRETE APRON CURE MATCR& SIDEWALK
AL — 5 LANES 7 65.97'
—
STRIPING
00 a
r. OJIOOC = j
LITTLE
ROGE
pp '>♦lAYK� q,
"'" LO G PRC)JYCT
ON
„z
N
laggl= 44
m
SITE NOTES
0
1. ALL WORK AND MATERIALS SHALL COMPLY WITH ALL
5.
ALL CURB/SIDEWALK/HANDICAP RAMP DESIGNS SHALL CONFORM TO ADA
CITY/COUNTY/STATE/FEDERAL REGULATIONS AND CODES AND OSHA
STANDARDS OR LOCAL RESTRICTIVE CODES, WHICHEVER IS MORE
STANDARDS.
RESTRICTIVE.
2. CONTRACTOR SHALL REFER TO ARCHITECTURAL PLANS FOR EXACT
6.
CONTRACTOR SHALL ENSURE ALL NECESSARY PERMITS ARE OBTAINED
Q
LOCATIONS AND DIMENSIONS OF VESTIBULES, SLOPE PAVING, SIDEWALKS,
PRIOR TO CONSTRUCTION START.
EXIT PORCHES, TRUCK DOCKS, PRECISE BUILDING DIMENSIONS AND EXACT
7.
CONTRACTOR SHALL MATCH PROPOSED CURB AND GUTTER, CONCRETE,
UTILITY ENTRANCE LOCATIONS.
AND PAVEMENT TO EXISTING IN GRADE AND ALIGNMENT.
c
0
WIS
3. ALL DIMENSIONS AND RADII ARE TO BACKOF CURB UNLESS OTHERWISE
B.
CONTRACTOR SHALL MAINTAIN ALL EXISTING PARKING SIDEWALKS
a
NOTED.
DRIVES, RI ETC. CLEAR AND FREE FROM ANY CONSTRUCTION ACTIVITY
'
4. ALL WORK SHALL BE DONE IN STRICT ACCORDANCE WITH THE PROJECT
AND/OR MATERIAL TO ENSURE EASY AND SAFE PEDESTRIAN AND
SPECIFICATIONS.
VEHICULAR TRAFFIC TO AND FROM THE SITE.
OWNERSHIP OF DOCUMENTS
THIS DOCUMENT
, AND THE IDEAS AND DESIGNS
INCORPORATED HEREIN, AS AN INSTRUMENT OF
PROFESSIONAL SERVICES, IS THE PROPERTY OF CRAFTON,
TULL. SPARKS & ASSOCIATES, INC., AND IS NOT TO BE
USED, IN WHOLE OR PART, FOR ANY OTHER PROJECT WITH
OUT THE WRITTEN AUTHORIZATION OF CRAFTON, TULL,
SPARKS & ASSOCIATES, INC.
Cr
�vm
GRAPHIC SCALE IN FEET
30' 0 30'
O
FOUND IRON PIN
•
SET IRON PIN
A
EXISTING LIGHT POLE
iR
EXISTING POWER POLE
+
PROPOSED POWER POLE
LTA
EXISTING TELEPHONE PEDESTAL
■
PROPOSED TELEPHONE PEDESTAL
® EXISTING ELECTRIC PEDESTAL
VICINITY MAP D4 EXISTING WATER VALVE
NTS N PROPOSED WATER VALVE
E
ENGINEER'S NOTICE TO CONTRACTOR
THE EXISTENCE AND LOCATION OF ANY UNDERGROUND
UTILITY PIPES OR STRUCTURES SHOWN ON THESE DRAWINGS
ARE OBTAINED BY A SEARCH OF THE AVAILABLE RECORDS.
TO THE BEST OF OUR KNOWLEDGE THERE ARE NO EXISTING
UTILITIES EXCEPT AS SHOWN ON THESE DRAWINGS AND WE
ASSUME NO RESPONSIBILITY AS TO THE ACCURACY OF
THEIR DEPICTED LOCATION ON THESE DRAWINGS. THE
CONTRACTOR IS REQUIRED TO TAKE DUE PRECAUTIONARY
MEASURES TO PROTECT THE UTLTY LINES SHOWN, AND
ALL OTHER LINES NOT OF RECORD OR NOT SHOWN ON THESE
DRAWINGS BY VERIFICATION OF THEIR LOCATION IN THE
FIELD PRIOR TO THE INITIATION OF THE ACTUAL PORTION
OF THEIR WORK.
SAFETY NOTICE TO CONTRACTOR
IN ACCORDANCE WITH GENERALLY ACCEPTED CONSTRUCTION
PRA
CTICES. THE CONTRACTOR WALL BE SOLELY AND
COMPLETELY RESPONSIBLE FOR CONDITIONS OF THE JOB
SITE, INCLUDING SAFETY OF ALL PERSONS AND PROPERTY
DURING PERFORMANCE OF THE WORK. THIS REQUIREMENT
WILL APPLY CONTINUOUSLY AND NOT BE LIMITED TO
NORM
AL WORKING HOURS.
THE DUTY OF THE ENGINEER TO CONDUCT CONSTRUCTION
REVIEW OF THE CONTRACTOR'S PERFORMANCE IS NOT
INTENDED TO INCLUDE REVIEW OF THE ADEQUACY OF THE
CONTRACTOR'S SAFETY MEASURES, IN, OR NEAR THE
CONSTRUCTION SITE.
DQ
EXISTING FIRE HYDRANT ASSEMBLY
PROPOSED FIRE HYDRANT ASSEMBLY
O
EXISTING WATER METER
10
PROPOSED WATER METER
O
EXISTING MANHOLE
Q
PROPOSED MANHOLE
EXISTING GAS METER
♦
PROPOSED GAS METER
F==
t=�
EXISTING GRATED INLET
PROPOSED GRATED INLET
At,
LL JJ
EXISTING DROP INLET
PROPOSED DROP INLET
X-X
PROPOSED STORM STRUCTURE NUMBER
C
DOWN GUY
C _--_-_-C
EXISTING REINFORCED CONCRETE PIPE
OR CORRUGATED METAL PIPE
O
NEW REINFORCED CONCRETE PIPE
OR CORRUGATED METAL PIPE
EXISTING CURB
1206
EXISTING INTERMEDIATE CONTOUR
1205
EXISTING INDEX CONTOUR
1206
PROPOSED INTERMEDIATE CONTOUR
1205
= .,JL_ 'NnFX
-iCPOSED CURB
SS
EXISTING SANITARY SEWER LINE
SS
PROPOSED SANITARY SEWER LINE
G
EXISTING GAS LINE
G
PROPOSED GAS LINE
W
EXISTING WATER LINE
W
PROPOSED WATER LINE
— UGT
EXISTING UNDERGROUND TELEPHONE
UGT—
PROPOSED UNDERGROUND TELEPHONE
UGE
EXISTING UNDERGROUND ELECTRIC
UGE
PROPOSED UNDERGROUND ELECTRIC
FO
EXISTING FIBER OPTIC
OHE
EXISTING OVERHEAD ELECTRIC
191HE
PROPOSED OVERHEAD ELECTRIC
UGTV
EXISTING UNDERGROUND TELEVISION
UGTV
- PROPOSED UNDERGROUND TELEVISION
OHTV
EXISTING OVERHEAD TELEVISION
— OHTV
- PROPOSED OVERHEAD TELEVISION
EXISTING WOOD FENCE
PROPOSED WOOD FENCE
EXISTING BARBED WIRE FENCE
X
PROPOSED BARBED WARE FENCE
EXISTING CHAIN LINK FENCE
PROPOSED CHAIN LINK FENCE
o --
PROPERTY LINE
----•--
—
BUILDING SET BACK
- ----- -- --
EXISTING EASEMENT
-- -- ---
PROPOSED EASEMENT
---
EXISTING RIGHT OF WAY
PROPOSED RIGHT OF WAY
--
EXISTING TREE
/ TREE TO BE REMOVED
NOTIFICATION OF LIMITED SERVICES
CRAFTON, TULL, SPARKS & AStOCIATES, INC., 'CTSA) HAS
NOT BEEN RETAINED BY THE CNNER FOR CONSTRUCTION
ADMINISTRATION OR OBSERVATDN SERVICES O,H ALL OR A
PORTION OF THE WORK INDICAED ON THESE FRAWINGS.
THEREFORE, THE CTSA HEREBYNOTIFIES ALL PARTIES
INVOLVED THAT THE CTSA ASSHMES NO RESPONSIBILITY FOR
THE INTERPRETATION COORDINATION AND ADMINIS
TRATION OF
THESE DOCUMENTS AND/OR DWIATIONS THEREFROM AND THE
L
EFFECTS THOSE CHANGES MAYHAVE ON ANY AND ALL
RELATED TRADES OR CONSTRICTION SEQUENCES, OR
OPERATION OF THE COMPLETE[ PROJECT. EXCEPT AS SPEC-
IFICALLY REQUIRED IN THE CTS's SERVICES AGREEMENT WITH
THE OWNER.
-
PAW& >
t"
AtS00AIB,Nw
dJ
k 109
2p;
AS k
I L'11\11L'141 f�JAS
REGISTERED
PROFESSIONAL
ENGINEER
No. 9407
�F'QRy J ��so
LO
LO
L >C7�
Ci
-SeC,4
L cV
�K�
N �a� -'0 0
Q i Q � N
CEO i
a)O`....�
U Lr) C
�Jd O
MIME COS O
�O
00 =
�V)� V �
c4i4
W
...
H
Z
W
U
c^
O
Z
0a
z
O
0
Z
Q
O
>
C/)
Z
W
Q
=C7a0
LLI
Y
J
=
O
J
Q
n-
�
W
J
H
Z
U
Revisions
Drawn by
BAP
Checked by
Date
05/23/08
SITE PLAN
Job Number
088010-00
Contact Person
J.KELSO
Sheet Number
l
Sp .0
/ d tb
O
1rLHIt, _