HomeMy WebLinkAboutDec 2023 PC Minutes for Z-9878December 14, 2023
ITEM NO.: 19 FILE NO.: Z-9878
NAME: Crimson Oaks – PD-R
LOCATION: 14118 Kanis Road
DEVELOPER:
Taylorized Properties
11524 Fairview Road
Little Rock, AR 72212
OWNER/AUTHORIZED AGENT:
J. Eric Holloway (Agent)
Holloway Engineering
200 Casey Drive
Maumelle, AR 72113
SURVEYOR/ENGINEER:
Holloway Engineering
200 Casey Drive
Maumelle, AR 72113
AREA: 6.35 acres NUMBER OF LOTS: 44 FT. NEW STREET: 1,468 LF
WARD: N/A PLANNING DISTRICT: 19 CENSUS TRACT: 42.12
CURRENT ZONING: R-2
A. PROPOSAL/REQUEST/APPLICANT’S STATEMENT:
The applicant is proposing to rezone the property from R-2 to PD-R in order to
subdivide 6.35 acres into 44 lots, and to construct fifteen (15) buildings of two (2)
and three (3) units each with a neighborhood pool and covered pickleball courts.
The subdivision will take access from Kanis Road. The development will also
include 1,468 linear-feet of new private streets and will be completed in one (1)
phase.
B. EXISTING CONDITIONS:
The site is located on the north side of Kanis Road, approximately 309 feet west
of Kirby Road. Properties around the site contain a mixture zoning and uses all
directions.
December 14, 2023
ITEM NO.: 19 (Cont.) FILE NO.: Z-9878
2
C. NEIGHBORHOOD NOTIFICATIONS:
All owners of property within 300 feet of the site and all neighborhood associations
registered with the City of Little Rock were notified of the public hearing.
D. ENGINEERING COMMENTS:
1. Contact Planning and Development Dept., Engineering Division at
501-371-4817 or at 501-918-5348 for inspections of any work in the public
right-of-way prior to placement of concrete or asphalt or for on-site
clarification of requirements prior to commencing work. Failure to do so can
result in removal of any improperly placed concrete or asphalt at the expense
of the owner or contractor.
2. Damage to public and private property due to hauling operations or
operations of construction related equipment from a construction site shall be
repaired by the responsible party prior to the issuance of a certificate of
occupancy.
3. Any work involving one (1) or more acres of disturbed area requires a
State of Arkansas NPDES permit. Contact the Arkansas Department of
Environmental Quality, NPDES branch at 501-682-0744 for applications and
information about General Stormwater Discharge Construction Permit
#ARR150000.
4. A grading permit must be obtained prior to initiation of work. Grading permits
are issued by the Planning and Development Dept. at 723 West Markham
Street after approval of sediment and erosion control plans, grading and
drainage plans, land survey, drainage study, and soil loss calculations per
City’s stormwater management and drainage manual. Contact Planning and
Development Dept., Engineering Division at 501-371-4817 or at 501-918-
5348 or Permits@littlerock.gov to schedule an appointment for issuance or
to answer any questions. Permit cost is based on total project area at
$100.00 for the less than ½ acre, $200.00 for ½ to 1 acre, and $200.00 for
the first acre and $100.00 for each additional acre for project greater than 1
acre.
5. The Department requires three (3) phase sediment and erosion control (SEC)
plans to be submitted for all construction projects showing best management
practices (BMPs) for mitigating sediment runoff and erosion along with
vegetation specifications for temporary and permanent soil stabilization.
Phase 1 SEC plans shall show SEC BMPs during the stripping, clearing,
grubbing, and rough grading of the site. Phase 2 SEC plans shall show SEC
BMPs during construction of utilities, buildings, roadway infrastructure and
drainage infrastructure. Phase 3 SEC Plans shall show SEC BMPs for final
grading, seeding, and landscaping of the site.
December 14, 2023
ITEM NO.: 19 (Cont.) FILE NO.: Z-9878
3
6. Sediment and Erosion Control plans shall also show the pertinent information
as outlined in ADEQ ARR150000 Permit Part II section A-4-H (1-14) and Part
II section A-4-I-2 (A-B).
7. A drainage study showing all hydrologic calculations for the site and all
hydraulic calculations for the proposed storm sewer pipe system, swales and
ditches, detention ponds, outlet structures, and inlets is required per City’s
stormwater management and drainage manual. For final drainage report,
sign, date, and seal the report per AR State Board of Professional Engineers
and Professional Surveyors rules Article 12, Section B (1) (a). Provide
engineer's certification statement saying this drainage report was conducted
by yourself or directly under your supervision and attesting to the accuracy of
the information within this report. Board of Professional Engineers and
Professional Surveyors rules Article 12, Section B (1) (a). Provide engineer's
certification statement saying this drainage report was conducted by yourself
or directly under your supervision and attesting to the accuracy of the
information within this report.
8. Per City Code 31-210 (e) (1) for arterial streets, the minimum driveway
spacing shall be three hundred (300) feet. Driveway spacing shall be
centerline to centerline. The minimum driveway spacing from the property
line shall be one hundred fifty (150) feet. A lot will require seven hundred fifty
(750) feet of frontage for two (2) driveways. Revise site plan accordingly or
a request for variances from these three City code requirements to the
Planning Commission as part of the application for the PD-R will be required.
9. Boundary street improvements are required per master street plan. Boundary
street improvements shall include, but not be limited to, reconstruction of one-
half section of the abutting street if the existing street is not up to city
standards. Repair, replace, or extend existing damaged, missing, and
noncompliant curb and gutter, sidewalk, access ramps or concrete driveway
aprons within the public right-of-way adjacent to the site. Remove abandoned
driveway cuts and replace with curb, gutter, and sidewalk. All work within the
public right-of-way shall conform to City of Little Rock Public Works Standard
Details and ADA guidelines.
10. Kanis Road is classified as a minor arterial per the City’s master street plan.
Therefore, per City’s boundary street ordinance, construction of boundary
street improvements along property’s southern frontage on Kanis Road for a
minor arterial street standard and dedication of additional right of way per
master street plan is required. Total right of way dedication required is forty-
five (45) feet from street centerline. Additional right of way dedicated from
the centerline of right of way more than forty-five (45) feet may be required
by Department staff depending on the location of the centerline of the street
in relation to the centerline of the right of way if both centerlines do not
coincide currently for Kanis Road.
December 14, 2023
ITEM NO.: 19 (Cont.) FILE NO.: Z-9878
4
11. Per City Code 31-89 (5) for a preliminary plat, a storm drainage preliminary
analysis is required showing drainage data for all watercourses entering and
leaving the plat boundaries. The storm drainage analysis shall be prepared
in sufficient detail to illustrate the proposed system’s capability of
accommodating storm events as required by the stormwater management
and drainage manual. The preliminary plat shall also show drainage arrows
indicating how drainage arrives at the site and drainage arrows how it leaves
the site post development. Indicate where the storm sewer pipes are located
within the development also. Additionally, provide profile and cross-sectional
views of the detention structure outlet/spillway. Delineation of the drainage
areas pre and post construction with respective discharges via rational
method shall also be shown. The preliminary plat shall also contain all
information as outlined in City Code 31-89.
12. A preliminary detention pond analysis for the 25 and 100 year storms is
required to be submitted to Department engineering staff for review prior to
Planning Commission agenda meeting to verify proposed detention ponds
have enough capacity to store and properly release each design storm event
per City’s stormwater management and drainage manual and City Code
Chapter 29.
13. Street design standards shall comply with the latest version of the AASHTO
A Policy on Geometric Design of Highways and Streets, City’s Master Street
Plan (2018), and City’s Standard Details for street and drainage facilities
improvements (2015).
14. Street stormwater and detention infrastructure design standards shall comply
with the City’s Stormwater Management and Drainage Manual (2016)
including City Code Chapters 29, 30, and 31.
15. Street pavement, sidewalks, curb and gutter, curb inlets, junction boxes,
accessible ramps, and storm sewer infrastructure shall comply with City’s
specifications for construction as outlined in City Code Chapters 30.
16. Private access is proposed for this property. In accordance with Little Rock
Code Section 31-207, private streets must be designed and constructed to
public street standards per City Code Chapters 29, 30, 31 and Little Rock’s
Master Street Plan.
17. Clearly label all interior private streets as “private” on preliminary plat.
18. Per 2021 Arkansas Fire Prevention Code Volume 1 Fire Appendix D Fire
Apparatus Access Roads Section D107 One or Two Family Residential
Developments D107.1 One or two family dwelling residential developments:
“Developments of one or two family dwellings where the number of dwelling
units exceeds 30 shall be provided with two separate and approved fire
apparatus access roads. Exceptions: 1. Where there are more than 30
dwelling unit accessed from a single public or private fire apparatus access
road and all dwelling units are equipped throughout with an approved
automatic sprinkler system in accordance with Section 903.3.1.1, 903.3.1.2
December 14, 2023
ITEM NO.: 19 (Cont.) FILE NO.: Z-9878
5
or 903.3.1.3, access from two directions shall not be required. 2. The number
of dwelling units accessed from a single fire apparatus access road shall not
be increased unless fire apparatus access roads will connect with future
development, as determined by the fire code official.” Therefore, the
construction of two (2) fire apparatus access roads or installation of an
automatic sprinkler system throughout all proposed residential dwelling units
is required. Per Appendix D of the fire code Section D101 General D101.1
Scope: “Fire apparatus access roads shall be in accordance with this
appendix and all other applicable requirements of the Arkansas Fire
Prevention Code. Requests for exceptions to Appendix D may be appealed
to the State Fire Marshal.
Section R401.3 Drainage. Surface drainage shall be diverted to a storm
sewer conveyance or other approved point of collection that does not create
a hazard. Lots shall be graded to drain surface water away from foundation
walls. The grade shall fall a minimum of 6 inches (152mm) within the first
10 feet (3048mm). Exception: Where lot lines, walls, slopes or other physical
barriers prohibit 6 inches (152mm) of fall within 10 feet (3048mm), drains or
swales shall be constructed to ensure drainage away from the structure.
Impervious surfaces within 10 feet (3048mm) of the building foundation shall
be sloped a minimum of 2 percent away from the building.
E. UTILITIES/FIRE DEPARTMENT/PARKS/COUNTY PLANNING:
Little Rock Water Reclamation Authority:
1. Please submit wastewater drawings to LRWRA for review and approval.
Entergy: No comments received.
Summit Utilities: No comments.
AT & T: No comments received.
Central Arkansas Water:
1. All Central Arkansas Water requirements in effect at the time of request for
water service must be met.
Fire Department:
Maintain Access:
Fire Hydrants.
Maintain fire apparatus access roads at fire hydrant locations as per Appendix D
of the 2021 Arkansas Fire Prevention Code Vol. 1 Section D103.1 Access road
December 14, 2023
ITEM NO.: 19 (Cont.) FILE NO.: Z-9878
6
width with a hydrant. Where a fire hydrant is located on a fire apparatus access
road, the minimum road width shall be 26 feet, exclusive of shoulders.
Grade
Maintain fire apparatus access roads as per Appendix D of the 2021 Arkansas Fire
Prevention Code Vol. 1 Section D103.2 Grade. Fire apparatus access roads
shall not exceed 10 percent in grade except as approved by the fire chief. If
the grade exceeds 10 percent, approval will be denied and the applicant must
submit request to be reviewed by Fire Chief for Approval.
Loading
Maintain fire apparatus access road design as per Appendix D of the 2021
Arkansas Fire Prevention Code Vol. 1 Section D102.1 Access and loading.
Facilities, buildings or portions of buildings hereafter constructed shall be
accessible to fire department apparatus by way of an approved fire apparatus
access road with an asphalt, concrete or other approved driving surface capable
of supporting the imposed load of fire apparatus weighing at least 75,000 pounds.
Dead Ends
Maintain fire apparatus access roads at dead end locations as per Appendix
D of the 2021 Arkansas Fire Prevention Code Vol. 1 Section D103.4 Dead
Ends. Dead-end fire apparatus access roads in excess of 150 feet shall be
provided with width and turnaround provisions in accordance with Table D103.4.
Requirements for Dead-end fire apparatus access roads.
Gates
Maintain fire apparatus access road gates as per Appendix D of the 2021
Arkansas Fire Prevention Code Vol. 1 Section D103.5 Fire apparatus access
road gates. Gates securing the fire apparatus access roads shall comply with
all of the following criteria:
1. Minimum gate width shall be 20 feet.
2. Gates shall be of swinging or sliding type.
3. Construction of gates shall be of material that allow manual operation by one
person.
4. Gate components shall be maintained in an operable condition at all times and
replaces or repaired when defective.
5. Electric gates shall be equipped with a means of opening the gate by fire
department personnel for emergency access. Emergency opening devices
shall be approved by the fire code official.
6. Manual opening gates shall not be locked with a padlock or chain and padlock
unless they are capable of being opened by means of forcible entry tools or
when a key box containing the keys to the lock is installed at the gate location.
December 14, 2023
ITEM NO.: 19 (Cont.) FILE NO.: Z-9878
7
7. Locking device specifications shall be submitted for approval by the fire code
official.
8. Electric gate operators, where provided, shall be listed in accordance with
UL 325.
9. Gates, intended for automatic operation shall be designed, constructed and
installed to comply with requirements of ASTM F 2200.
Multi-Family Residential Developments
As per Appendix D, Section D106.1 of the 2021 Arkansas Fire Prevention
Code Vol. 1. Projects having more than 100 dwelling units. Multiple-family
residential projects having more than 100 dwelling units shall be equipped
throughout with two separate and approved fire apparatus access roads.
Exception: Projects having up to 200 dwelling units may have a single
approved fire apparatus access road when all building, including nonresidential
occupancies are equipped throughout with approved automatic sprinkler systems
installed in accordance with Section 903.3.1.1 or 903.3.1.2
As per Appendix D, Section D106.2 of the 2021 Arkansas Fire prevention
Code Vol. 1. Projects having more than 200 dwelling units. Multiple-family
residential projects having more than 200 dwelling units shall be provided with two
separate and approved fire apparatus access roads regardless of whether they
are equipped with an approved automatic sprinkler system.
Fire Hydrants
Locate Fire Hydrants as per Appendix C of the 2021 Arkansas Fire
Prevention Code. Section C101 – C105, in conjunction with Central Arkansas
Water (Daniel Tull 501-377-1245) and the Little Rock Fire Marshal’s Office
(Capt. Tony Rhodes 501-918-3757, or Fire Marshal Derek N. Ingram
501-918-3756 Number and Distribution of Fire Hydrants as per Table C105.1.
Parks and Recreation: No comments received.
County Planning:
1. No comments by Pulaski County unless the proposed subdivision is not
annexed into the City.
F. BUILDING CODES/LANDSCAPE:
Building Code: No comments received.
Landscape:
1. Any new site development must comply with the City’s minimal landscape and
buffer ordinance requirements. Refer to the Code of Ordinances, Chapter 15
December 14, 2023
ITEM NO.: 19 (Cont.) FILE NO.: Z-9878
8
Landscaping and Tree Protection, and Chapter 36, Article IX – Buffers and
Screening.
2. Site development plans, with landscape and screening, must be submitted for
review, and approval, prior to site clearing and tree removal.
G. TRANSPORTATION/PLANNING:
Rock Region Metro: No comments received.
Planning Division:
The request is in the Ellis Mountain Planning District. The Land Use Plan shows
Commercial (C) for the requested area. The Commercial (C) category includes a
broad range of retail and wholesale sales of products, personal and professional
services, and general business activities. Commercial activities vary in type and
scale, depending on the trade area that they serve. The application is to rezone
from R2 to PD-R. This property is located in the Extra Territorial Jurisdiction.
Surrounding the application area
To the west on the north side of Kanis Road is Commercial (C) land use. South of
the application site across Kanis Road is Residential High Density (RH) with a
developed apartment complex. The Residential High Density (RH) category
accommodates residential development of more than twelve (12) dwelling units
per acre. East of the site is Residential Medium Density (RM) with a developed
apartment complex and an area of Mixed Office and Commercial (MOC) with a
convenience store with fuel pumps. The Residential Medium Density (RM)
accommodates a broad range of housing types including single family attached,
single family detached, duplex, town homes, multi-family and patio or garden
homes. Any combination of these and possibly other housing types may fall in this
category provided that the density is between six (6) and twelve (12) dwelling units
per acre. The Mixed Office and Commercial (MOC) category provides for a mixture
of office and commercial uses to occur. Acceptable uses are office or mixed office
and commercial. A Planned Zoning District is required if the use is mixed office
and commercial.
This site is not in an Overlay District.
Master Street Plan:
Kanis Road is a Minor Arterial on the Master Street Plan. Minor Arterials are high
volume roads designed to provide the connections to and through an urban area.
Curb cuts should be minimized to allow for continuous traffic flow while still allowing
some access to adjoining property. Standard Right-of-way (ROW) is 90 feet.
December 14, 2023
ITEM NO.: 19 (Cont.) FILE NO.: Z-9878
9
Sidewalks are required on both sides. This street may need more ROW and/or
paving width. May require dedication of ROW or improvements.
Bicycle Plan:
The Master Bike Plan shows no facilities in this area.
Historic Preservation Plan:
This property is not a contributing structure and is not located in a Historic District.
H. ANALYSIS:
The applicant is proposing to rezone the property from R-2 to PD-R in order to
subdivide 6.35 acres into 44 lots, and to construct fifteen (15) buildings of two (2)
and three (3) units each with a neighborhood pool and covered pickleball courts.
The subdivision will take access from Kanis Road. The development will also
include 1,468 linear-feet of new private streets and will be completed in one (1)
phase.
The site is located on the north side of Kanis Road, approximately 309 feet west
of Kirby Road. Properties around the site contain a mixture zoning and uses all
directions.
Access to each unit will be from a private drive extending from Kanis Road.
Currently all lots will be owned or leased by the developer, however, each unit may
be for sale in the future.
The plan shows an average lot size of 0.099 acre with a typical unit size of
2,080 square feet. Each unit will contain a 2-car garage and a 20-foot wide
driveway. Buildings will not exceed a maximum building height of thirty-five (35)
feet.
All front building setbacks will be twenty (20) feet, rear setbacks range from five
(5) to fifteen (15) feet. All connected buildings have a zero (0) setback at the
common building line.
A mail kiosk is located near the entrance of the development along Kanis Road.
There will be a separate entrance at the southeast corner of the property to serve
the mail kiosk area.
Two (2) covered pickleball courts and a pool and spa are located in the
southeastern portion of the development. The plan shows three (3) parking spaces
dedicated for the pool/pickleball area and for mail kiosk parking.
December 14, 2023
ITEM NO.: 19 (Cont.) FILE NO.: Z-9878
10
The plan shows water detention along the eastern and southeastern portion of the
development.
A twelve (12) foot (maximum height) retaining wall is shown along the eastern
boundary of the site. Four (4) foot and eight (8) foot high retaining walls are shown
along the north property boundary.
The applicant notes access easements, walking paths and all open space tracts
will be owned and maintained by the POA.
The applicant is not proposing any signage at this time. All signage must conform
to Section 36-551 (signs permitted in residential one- and two-family zones).
Staff is not opposed to the overall concept of the development. However, staff
does not feel that the site can be developed as presented, without substantial
changes, based on the following concerns:
1. Drainage infrastructure along Kanis Road needs to be within the right-of-way
and be designed to accommodate all upstream basin pre-development flows.
2. There will be additional drainage infrastructure within the site, which is not
shown on the plan.
3. All common areas, including the private roadways must be within tracts, and
maintained by a POA.
4. All private roads must be designed and constructed to City standards. The
east/west roads do not comply.
5. Sidewalks are not shown throughout the development, to provide pedestrian
connectivity to the common areas (pool and pickle ball courts) and mail
kiosk area.
6. The driveways for Lots 18 through 44 must have depths of at least twenty (20)
feet.
7. Staff does not support the design of the mail kiosk area. Staff’s has concerns
with pedestrian and vehicular access to this area.
8. Staff has concerns with respect to the design of the retaining walls in
conjunction with stormwater detention areas.
Therefore, staff does not support the evelopment at this time. Staff does not feel
that the proposed development is ready to be reviewed and acted upon by the
Planning Commission.
I. STAFF RECOMMENDATION:
Staff recommends denial of the PD-R rezoning as submitted.
December 14, 2023
ITEM NO.: 19 (Cont.) FILE NO.: Z-9878
11
December 14, 2023
ITEM NO.: 19 (Cont.) FILE NO.: Z-9878
12
PLANNING COMMISSION ACTION: (DECEMBER 14, 2023)
This item is being withdrawn, without prejudice, at the request of the applicant.