HomeMy WebLinkAboutZ-8278-A Application 2James, Donna
From: Jim Cranor <jcranor@pulaskicounty.net>
Sent: Friday, April 20, 2018 8:30 AM
To: James, Donna
Cc: Van McClendon
Subject: County comments for S-1813, S-1814, and S-1815
Donna,
Pulaski County comments as follows:
S-1813 -Dedicate Right of Way to meet the Little Rock Master Street Plan on both Geyer Springs Road and
Geyer Springs Cut-off.
-Provide perc test prior to Pulaski County Planning prior to requesting a 911 address if the new facility
has restroom facilities.
-Show FEMA flood panel on survey
-Provide approval letter from the N.E. Saline Volunteer Fire Department.
S-1814 -Dedicate Right of Way to meet the Little Rock Master Street Plan for Willow Springs Road,
-Provide perc test prior to Pulaski County Planning prior to requesting a 911 address.
-Provide approval letter from the Arch Street Volunteer Fire Department.
S-1815 -Dedicate Right of Way to meet the Little Rock Master Street Plan for Frazier Pike.
-Proposed building is within the platted building setback line and is also over the property line.
- Provide approval letter from the Sweet Home Volunteer Fire Department.
Feel free to call if you have any further questions.
Thanks,
Jim
Jim Cranor RLA, CFM
Pulaski County Planning and Development
3200 Brown Street
Little Rock, AR 72204
501-340-8265
MEMORANDUM
TO: DONNA JAMES, SUBDIVISION ADMINISTRATOR
FROM: TRACY SPILLMAN, PLANS DEVELOPMENT ADMINISTRATOR
SUBJECT: REVIEW OF THE BUFFER AND LANDSCAPE REQUIREMENTS OF
THE APRIL 25, 2018, SUBDIVISION COMMITTEE MEETING
CC: DANA CARNEY, ZONING & SUBDIVISION MANAGER
DATE: APRIL 20, 2018
1. 16307 Taylor_Loop Road (S-1811)
No comment.
2. 2700 --- 3300 Block of South Shackleford Road S-1812
Site plan must comply with the City's minimal landscape and buffer ordinance
requirements.
The City Beautiful Commission recommends preserving as many existing trees as
feasible on this site. Credit toward fulfilling Landscape Ordinance requirements can be
given when preserving trees of six (6) inch caliper or larger.
3. 5816 Geyer Springs Road S-1813
Any new site development must comply with the City's minimal landscape and buffer
ordinance requirements.
The City Beautiful Commission recommends preserving as many existing trees as
feasible on this site. Credit toward fulfilling Landscape Ordinance requirements can be
given when preserving trees of six (6) inch caliper or larger.
4. 4624 Willow Springs Road S-1814
No comment.
5. 4004 Frazier Park (S-1815)
Any new site development must comply with the City's minimal landscape and buffer
ordinance requirements.
The City Beautiful Commission recommends preserving as many existing trees as
feasible on this site. Credit toward fulfilling Landscape Ordinance requirements can be
given when preserving trees of six (6) inch caliper or larger.
6. 2712 Kavanauszh Blvd and 703 Beachwood Street Z-5309-A
Any new site development must comply with the City's minimal landscape and buffer
ordinance requirements and the requirements of the Hillcrest Design Overlay District.
Street buffers will be required at six (6) percent of the average depth of the lot. The
minimum dimension shall be one-half (%) the full width requirement but in no case less
than nine (9) feet. In addition to the required screening, buffers are to be landscaped at
the rate of one (1) tree and three (3) shrubs for every thirty (30) linear feet. The property
is located in the City's designated mature area. A twenty-five (25%) percent reduction of
the buffer width requirements is acceptable.
Screening requirements will need to be met for the vehicular use areas adjacent to street
right-of-ways. Provide screening shrubs with an average linear spacing of not less at three
(3) feet within the required landscape area. Provide trees with an average linear spacing
of not less than thirty (30) feet.
A land use buffer six (6) percent of the average width / depth of the lot will be required
when an adjacent property has a dissimilar use of a more restrictive nature. The property
to the north is zoned PD-R. As a component of all land use buffer requirements, opaque
screening, whether a fence or other device, a minimum of six (6) feet in height shall be
required upon the property line side of the buffer. In addition to the required screening,
buffers are to be landscaped at the rate of one (1) tree and three (3) shrubs for every
thirty (30) linear feet.
A perimeter planting strip is required along any side of a vehicular use area that abuts
adjoining property, or the right-of-way of any street. This strip shall be at least nine (9)
feet wide. One (1) tree and three (3) shrubs or vines shall be planted for every thirty (30)
linear feet of perimeter planting strip. A twenty-five (25%) percent reduction of the
perimeter width requirements is acceptable. The minimum perimeter width adjacent to
the north property line shall be six (6) feet nine (9) inches. The north perimeter is
deficient and may require a variance from the City Beautiful Commission.
Building landscape areas shall be provided at the rate equivalent to planter strip three (3)
feet wide along the vehicular use area. One (1) tree and four (4) shrubs shall be planted in
the building landscape areas for each forty (40) linear feet of vehicular use area abutting
the building.
Eight percent (8%) of the vehicular use area must be designated for green space; this
green space needs to be evenly distributed throughout the parking area(s). The minimum
size of an interior landscape area shall be one hundred fifty (150) square feet for
developments with one hundred fifty (150) or fewer parking spaces. Interior islands must
be a minimum of seven and one half (7 1/2) feet in width. Trees shall be included in the
interior landscape areas at the rate of one (1) tree for every twelve (12) parking spaces.
A landscape irrigation system shall be required for developments of one (1) acre or
larger.
The City Beautiful Commission recommends preserving as many existing trees as
feasible on this site. Credit toward fulfilling Landscape Ordinance requirements can be
given when preserving trees of six (6) inch caliper or larger.
7. 9222 Stagecoach Road (Z-6178-K)
Any new site development must comply with the City's minimal landscape and buffer
ordinance requirements.
Any new building rehabilitation or expansion may require the existing landscaping,
buffer, or vehicular use areas not meeting the current code requirements to be
brought into compliance.
The City Beautiful Commission recommends preserving as many existing trees as
feasible on this site. Credit toward fulfilling Landscape Ordinance requirements can be
given when preserving trees of six (6) inch caliper or larger.
8. 600 South Universi Z-7278-A
Any new site development must comply with the City's minimal landscape and buffer
ordinance requirements.
Street buffers will be required at six (6) percent of the average depth of the lot. The
minimum dimension shall be one-half ('/z) the full width requirement but in no case less
than nine (9) feet.
Screening requirements will need to be met for the vehicular use areas adjacent to street
right-of-ways. Provide screening shrubs with an average linear spacing of not less at three
(3) feet within the required landscape area. Provide trees with an average linear spacing
of not less than thirty (30) feet.
A perimeter planting strip is required along any side of a vehicular use area that abuts
adjoining property, or the right-of-way of any street. This strip shall be at least nine (9)
feet wide. The perimeter planting strip adjacent to freeways or expressways shall be at
least thirty (30) feet wide One (1) tree and three (3) shrubs or vines shall be planted for
every thirty (30) linear feet of perimeter planting strip. Perimeter plantings are to be
provided from the property line adjacent to the street right-of-way up to the front
building line in industrial properties. The perimeter planting strip adjacent to the I-630
right-of-way is deficient.
Land use buffers are to be maintained adjacent to the west R-5 zoned properties. As a
component of all land use buffer requirements, opaque screening, whether a fence or
other device, a minimum of six (6) feet in height shall be required upon the property line
side of the buffer. A minimum of seventy (70) percent of the land use buffer shall be
undisturbed. Easements cannot count toward fulfilling this requirement. In addition to
the required screening, buffers are to be landscaped at the rate of one (1) tree and three
(3) shrubs for every thirty (30) linear feet. Existing plant material can be used to meet
these minimum requirements.
Building landscape areas shall be provided at the rate equivalent to planter strip three (3)
feet wide along the vehicular use area. One (1) tree and four (4) shrubs shall be planted in
the building landscape areas for each forty (40) linear feet of vehicular use area abutting
the building.
Eight percent (8%) of the vehicular use area must be designated for green space; this
green space needs to be evenly distributed throughout the parking area(s). The minimum
size of an interior landscape area shall be one hundred fifty (150) square feet for
developments with one hundred fifty (150) or fewer parking spaces. Interior islands must
be a minimum seven and one half (7 1/2) feet in width. Trees shall be included in the
interior landscape areas at the rate of one (1) tree for every twelve (12) parking spaces.
A landscape irrigation system shall be required for developments of one (1) acre or
larger.
The development of two (2) acres or more requires the landscape plan to be stamped with
the seal of a Registered Landscape Architect.
The City Beautiful Commission recommends preserving as many existing trees as
feasible on this site. Credit toward fulfilling Landscape Ordinance requirements can be
given when preserving trees of six (6) inch caliper or larger.
9. 9601 Colonel Glenn Road (2-9319)
Site plan must comply with the City's minimal landscape and buffer ordinance
requirements.
Street buffers will be required at six (6) percent of the average depth of the lot. The
minimum dimension shall be one-half ('/2) the full width requirement but in no case less
than nine (9) feet.
Screening requirements will need to be met for the vehicular use areas adjacent to street
right-of-ways. Provide screening shrubs with an average linear spacing of not less at three
(3) feet within the required landscape area. Provide trees with an average linear spacing
of not less than thirty (30) feet.
A perimeter planting strip is required along any side of a vehicular use area that abuts
adjoining property or the right-of-way of any street, highway or freeway. This strip shall
be at least nine (9) feet wide. Provide trees with an average linear spacing of not less than
thirty (30) feet within the perimeter planting strip. Provide three (3) shrubs or vines for
every thirty (30) linear feet of perimeter planting strip. A portion of the west perimeter
planting strip is deficient.
Landscape areas shall be provided between the vehicular use area used for public parking
and the general vicinity of the building, excluding truck loading or service areas not open
to public parking. These areas shall be equal to an equivalent planter strip three (3) feet
wide along the vehicular use area.
Eight percent (8%) of the vehicular use area must be designated for green space; this
green space needs to be evenly distributed throughout the parking area(s). The minimum
size of an interior landscape area shall be one hundred fifty (150) square feet for
developments with one hundred fifty (150) or fewer parking spaces. Interior islands must
be a minimum seven and one half (7 1/2) feet in width. Trees shall be included in the
interior landscape areas at the rate of one (1) tree for every twelve (12) parking spaces.
Land use buffers are to be maintained adjacent to the south and east R-2 zoned
properties. As a component of all land use buffer requirements, opaque screening,
whether a fence or other device, a minimum of six (6) feet in height shall be required
upon the property line side of the buffer. A minimum of seventy (70) percent of the
land use buffer shall be undisturbed. Easements cannot count toward fulfilling this
requirement. In addition to the required screening, buffers are to be landscaped at the
rate of one (1) tree and three (3) shrubs for every thirty (30) linear feet. Existing plant
material can be used to meet these minimum requirements.
A landscape irrigation system shall be required for developments of one (1) acre or
larger.
The development of two (2) acres or more requires the landscape plan to be stamped with
the seal of a Registered Landscape Architect.
The City Beautiful Commission recommends preserving as many existing trees as
feasible on this site. Credit toward fulfilling Landscape Ordinance requirements can be
given when preserving trees of six (6) inch caliper or larger.
10. 6400 West Markham St NWC Markham and McKinley Streets Z-9320
No comment.
11. 4208 Fairview lid (Z-9321)
No comment.
12. 15901 Taylor Loop Road Z-9322
No comment.
13. 818 West Capitol (Z-9323)
Any new site development must comply with the City's minimal landscape and buffer
ordinance requirements and the requirements of the UU Urban Use District.
Any existing vehicular use area that does not meet current code requirements may
continue as nonconforming until such time a building permit is issued to rehabilitate a
structure on the property exceeding fifty (50) percent of the current replacement cost of
the structure. At such time fifty (50) percent of the existing vehicular use area shall be
brought into compliance with this chapter and shall continue to full compliance on a
graduated scale based upon the percentage of rehabilitation cost.
The City Beautiful Commission recommends preserving as many existing trees as
feasible on this site. Credit toward fulfilling Landscape Ordinance requirements can be
given when preserving trees of six (6) inch caliper or larger.
Z-5309-A
Address: 2712 Kavanaugh
Boulevard and 703
Beachwood Street
Planning Division: This request is located in Heights Hillcrest Planning District.
The Land Use Plan shows Commercial (C) for these properties. The Commercial
category includes a broad range of retail and wholesale sales of products, personal
and professional services, and general business activities. Commercial activities
vary in type and scale, depending on the trade area that they serve. The applicant
has applied for a rezoning from C3 (General Commercial District) and 03 (General
Office District) to (Planned Commercial Development) to allow a restaurant with
common outdoor space and parking. The request is within the Hillcrest Design
Overlay District.
Master Street Plan: West of the properties is Beechwood Street and it is shown as
a Local Street on the Master Street Plan. South of the properties is Kavanaugh
Boulevard and it is shown as a Collector on the Master Street Plan. The primary
function of a Local Street is to provide access to adjacent properties. Local Streets
that are abutted by non-residential zoning/use or more intensive zoning than
duplexes are considered as "Commercial Streets". A Collector design standard is
used for Commercial Streets. The primary function of a Collector Road is to provide
a connection from Local Streets to Arterials. These streets may require dedication
of right-of-way and may require street improvements for entrances and exits to the
site.
Bicycle Plan: There is a Class III Bike Route shown on Kavanaugh Blvd. These
bike routes require no additional right-of-way, but either a sign or pavement
marking to identify and direct the route.
Z-6178-K Address: 9222 stagecoach
Road
Planning Division: This request is located in Otter Creek Planning District. The
Land Use Plan shows Mixed Use (MX) for this property. The Mixed Use category
provides for a mixture of residential, office, and commercial uses to occur. A
Planned Zoning District is required if the use is entirely office or commercial or if
the use is a mixture of the three. The applicant has applied for a revised Short -
form POD (Planned Office District) to allow for the addition of `restaurant' as a
permitted use in the existing structure.
Master Street Plan: East of the property is Stagecoach Road and it shown as a
Minor Arterial on the Master Street Plan. South of the property is Stagecoach
Village Drive and it is shown as a proposed Local Street on the Master Street
Plan. A Minor Arterial provides connections to and through an urban area and
their primary function is to provide short distance travel within the urbanized area.
Entrances and exits should be limited to minimize negative effects of traffic and
pedestrians on Stagecoach Road. The primary function of a Local Street is to
provide access to adjacent properties. Local Streets that are abutted by non-
residential zoning/use or more intensive zoning than duplexes are considered as
"Commercial Streets". A Collector design standard is used for Commercial
Streets. These streets may require dedication of right-of-way and may require
street improvements for entrances and exits to the site.
Bicycle Plan: A Class II Bike Lane is shown along Stagecoach Road. Bike Lanes
provide a portion of the pavement for the sole use of bicycles.
Z-8278-A
Address: 600 South
University Avenue — NWC
of University Avenue and I-
630
Planning Division: This request is located in West Little Rock Planning District. .
The Land Use Plan shows Mixed Use (MX) for this property. The Mixed Use
category provides for a mixture of residential, office, and commercial uses to occur.
A Planned Zoning District is required if the use is entirely office or commercial or if
the use is a mixture of the three. The applicant has applied for a rezoning from
PCD (Planned Commercial District) and C3 (General Commercial District) to PCD
(Planned Commercial Development) to allow commercial and office development.
The request is within the Midtown Design Overlay District
Master Street Plan: Midtown Ave and West Est Street and S McKinley Street are
all shown as Local Streets on the Master Street Plan. East of the properties is S
University Avenue and it shown as a Principal Arterial on the Master Street Plan.
South of the properties is Interstate 630 and it is shown and a Freeway on the
Master Street Plan. The primary function of a Local Street is to provide access to
adjacent properties. Local Streets that are abutted by non-residential zoning/use
or more intensive zoning than duplexes are considered as "Commercial Streets".
A Collector design standard is used for Commercial Streets. The primary function
of a Principal Arterial Street is to serve through traffic and to connect major traffic
generator or activity centers within an urbanized area. Entrances and exits should
be limited to minimize negative effects of traffic and pedestrians on S University
Avenue since it is a Principal Arterial. The primary function of a Freeway is to serve
through long distance trips. Freeways are always designed as full access control
roads (no direct access) Entrances and exits should be limited to minimize
negative effects of traffic and pedestrians on 1-630 since it is a Freeway. These
streets may require dedication of right-of-way and may require street
improvements for entrances and exits to the site.
Bicycle Plan: There is a Class III Bike Route shown on Midtown Avenue. These
bike routes require no additional right-of-way, but either a sign or pavement
marking to identify and direct the route.
Z-9319
Address: 9601 Colonel
Glenn Road
Planning Division: This request is located in 65th Street West Planning District.
The Land Use Plan shows Mixed Use (MX) for this property The Mixed Use
category provides for a mixture of residential, office, and commercial uses to occur.
A Planned Zoning District is required if the use is entirely office or commercial or if
the use is a mixture of the three. The applicant has applied for a Rezoning from a
R2 (Single Family District) to a PCD (Planned Commercial Development) to allow
a retail store to be built.
Master Street Plan: North of the property is Colonel Glenn Road and is shown as
a Principal Arterial on the Master Street Plan. The primary function of a Principal
Arterial Street is to serve through traffic and to connect major traffic generator or
activity centers within an urbanized area. Entrances and exits should be limited
to minimize negative effects of traffic and pedestrians on Colonel Glenn Road
since it is a Principal Arterial. This streets may require dedication of right-of-way
and may require street improvements for entrances and exits to the site.
Bicycle Plan: A Class II Bike Lane is shown along Colonel Glenn Road. Bike Lanes
provide a portion of the pavement for the sole use of bicycles.
Z-9320 Address: 6400 West
Markham Street, NWC
Markham and McKinley
Streets
Planning Division: This request is located in West Little Rock Planning District.
The Land Use Plan shows Residential Low Density Use (RL) for this property.
Residential Low category provides for single family homes at densities not to
exceed 6 dwelling units per acre. Such residential development is typically
characterized by conventional single family homes, but may also include patio or
garden homes and cluster homes, provided that the density remain less than 6
units per acre. The applicant has applied for a rezoning from R2 (Single Family
District) to PDR (Planned Development Residential) to allow for 6 Patio Homes on
half an acre (12 units/acre density).
Master Street Plan: South of the property is W Markham Street and it shown as a
Minor Arterial on the Master Street Plan. East of the property is North McKinley
Street and it shown as a Local Street on the Master Street Plan. Minor Arterial
provides connections to and through an urban area and their primary function is
to provide short distance travel within the urbanized area. Entrances and exits
should be limited to minimize negative effects of traffic and pedestrians on W
Markham Street. The primary function of a Local Street is to provide access to
adjacent properties. Local Streets that are abutted by non-residential zoning/use
or more intensive zoning than duplexes are considered as "Commercial Streets".
A Collector design standard is used for Commercial Streets. These streets may
require dedication of right-of-way and may require street improvements for
entrances and exits to the site.
Bicycle Plan: There are Class III Bike Routes shown on W Markham and North
McKinley Streets. These bike routes require no additional right-of-way, but either
a sign or pavement marking to identify and direct the route.
Z-9321 Address: 4208 Fairview
Road
Planning Division: This request is located in Heights Hillcrest Planning District.
The Land Use Plan shows Residential Low Density Use (RL) for this property.
Residential Low category provides for single family homes at densities not to
exceed 6 dwelling units per acre. Such residential development is typically
characterized by conventional single family homes, but may also include patio or
garden homes and cluster homes, provided that the density remain less than 6
units per acre. The applicant has applied for a rezoning from R2 (Single Family
District) to PDR (Planned Development Residential) to allow an existing 1 story to
be remodeled into a 2 story house. The request is within the Hillcrest Design
Overlay District.
Master Street Plan: West of the property is Fairview Road and it shown as a
Local Street on the Master Street Plan. The primary function of a Local Street is
to provide access to adjacent properties. This Streets may require dedication of
right-of-way and may require street improvements for entrances and exits to the
site.
Bicycle Plan: There are no bike routes shown in the immediate vicinity.
Z-9322 Address: 15901 Taylor
Loop Road
Planning Division: This request is located in Chenal Planning District. The Land
Use Plan shows Residential Low Density Use (RL) for this property. Residential
Low category provides for single family homes at densities not to exceed 6 dwelling
units per acre. Such residential development is typically characterized by
conventional single family homes, but may also include patio or garden homes and
cluster homes, provided that the density remain less than 6 units per acre. The
applicant has applied for a Rezoning from R2 (Single Family District) to PDR
(Planned Development Residential) to build 8 Townhouses units on 0.9 acres of
land (approximately 9 units/acre).
Master Street Plan: North of the Property is Taylor Loop Road and it shown as a
Collector on the Master Street Plan. West of the property is Gooch Drive and it
shown as a Local Street on the Master Street Plan. This Streets may require
dedication of right-of-way and may require street improvements for entrances
and exits to the site. The primary function of a Collector Road is to provide a
connection from Local Streets to Arterials. The primary function of a Local Street
is to provide access to adjacent properties. A Collector design standard is used
for Commercial Streets. These streets may require dedication of right-of-way
and may require street improvements for entrances and exits to the site.
Bicvcle Plan: A Class II Bike Lane is shown along Taylor Loop Road. Bike Lanes
provide a portion of the pavement for the sole use of bicycles.
Z-9323 Address: 818 West Capitol
Planninq Division. This request is located in Downtown Planning District. The Land
Use Plan shows Mixed Use Urban (MXU) for this property. The Mixed Use Urban
category provides for a mix of residential, office and commercial uses not only in
the same block but also within the same structure. This category is intended for
older "urban" areas to allow dissimilar uses to exist, which support each other to
create a vital area. Development should reinforce the urban fabric cresting a 24-
hour activity area. Using the Planned Zoning District or the Urban Use District, high
and moderate density developments that result in a vital (dense) pedestrian
oriented area are appropriate. The applicant has applied for a rezoning from UU
(Urban Use) to PCD (Planned Commercial Development) to allow a private club in
an existing building.
Master Street Plan: South of the property is W Capitol Avenue and it is shown as
a Collector on the Master Street Plan. West of the property is S Izard Street and
it is shown as a Local Street on the Master Street Plan. The primary function of a
Collector Road is to provide a connection from Local Streets to Arterials. The
primary function of a Local Street is to provide access to adjacent properties.
Local Streets that are abutted by non-residential zoning/use or more intensive
zoning than duplexes are considered as "Commercial Streets". A Collector
design standard is used for Commercial Streets. These Streets may require
dedication of right-of-way and may require street improvements for entrances
and exits to the site.
Bicycle Plan: There are no bike routes shown in the immediate vicinity.
Entergy Arkansas Inc.
#9 Entergy Court
Little Rock. AR 72211
April 17, 2018
City of Little Rock
Department of Planning and Development
ATTN: Ms. Donna James, AICP
723 West Markham Street
Little Rock, AR 72201-1334
RE: Entergy comments related to Planning and Zoning items for the May 17" Meeting
Ms. James,
Please find below Entergy's comments related to the items received from the Department of Planning and
Development this week. The request letter said to have the comments back to you by April 23`d, 2018.
the District at Midtown — Long -form PCD — 600 So. University Ave. — Z-8278-AE
Entergy does not object to this proposal. However, there are multiple electrical Distribution power lines
running around and through this property. The lines on the west side and north side of the area are
overhead power lines. There is an underground power line running east and west across the center of the
property along the path of what was previously 61' Street. There is an underground power line running
along the east side of the property beginning on the west side of University and I-630 extending north.
Entergy has met previously with a developer about this property. Contact Entergy in advance to discuss
electrical service requirements, conduit layout, and adjustments to existing facilities (if any) as this
project proceeds.
• 2712 Kavanaugh Short -form PCD — 2712 Kavanaugh Blvd & 703 Beechwood St.— Z-5309-A
Entergy does not object to this proposal. However, as noted on the Site Plan drawing, there is an existing
three-phase overhead power line running along Kavanaugh in front of this property. All OSHA and Code
clearances to this power line must be maintained during and after construction of the Proposed Building.
There is also a single phase, overhead power line running along the east side of the alley on the east side
of the property. The same clearance requirements exist for this line as well during and after construction.
Lastly, note that the proposed dumpster location must take into account any overhead power lines which
are in the area. Any dumpster handling must maintain at least 10 feet clearance from any overhead line.
Contact Entergy in advance to discuss electrical service requirements, or adjustments to existing facilities
(if any) as this project proceeds.
• Stagecoach Village Lot 1 Revised short -form POD — 9222 Stagecoach Rd. — Z-6178-K
Entergy does not object to this proposal. There do not appear to be any conflicts with existing electrical
utilities at this location. Service is already being provided to the building on Lot 2. There is an overhead,
three phase power line running along the eastern and northern edge of Lotl and also along the northern
edge of Lot 3 which will need to be accounted for during future development. Contact Entergy in
advance to discuss electrical service requirements, or adjustments to existing facilities (if any) as this
project proceeds.
PB General Holdings, LR Colonel Glenn short -form PCD — 9601 Colonel Glenn Rd — Z-9319
Entergy does not object to this proposal. There do not appear to be any conflicts with existing electrical
utilities at this location. There is an existing three phase, overhead power line on the north side of
Colonel Glenn Road in front of this property. There is also a single phase, overhead power line running
along the east side of the property. Contact Entergy in advance to discuss electrical service requirements,
or adjustments to existing facilities (if any) as this project proceeds.
Gramercy Park Short -form PD-R — 6400 West Markham St — Z-9320
Entergy does not object to this proposal. There do not appear to be any conflicts with existing electrical
utilities at this location. There is an existing three phase, overhead power line on the west side of
McKinley adjacent to this property. There is also a single phase, overhead power line running east and
west along Gramercy Park drive which will need to remain in place to serve existing Entergy customers
on the west side of this project. Service is already being provided to existing structures in the project area
which will need to be addressed. Contact Entergy in advance to discuss electrical service requirements,
or adjustments to existing facilities (if any) as this project proceeds.
Townhouse Apartments Short -form PD-R —15901 Taylor Loop Rd — Z-9322
Entergy does not object to this proposal. There do not appear to be any conflicts with existing electrical
utilities at this location. However, there is a three phase, overhead power on the north side of this
property along Taylor Loop Road and a single phase power line running along the east side of Gooch
Drive. Construction of the project requires that all applicable clearances to the power lines be maintained
during and after construction of the Townhouses. Contact Entergy in advance to discuss electrical service
requirements, or adjustments to existing facilities (if any) as this project proceeds.
+ 818 West Capitol Short -form PCD — 818 West Capitol — Z-9323
Entergy does not object to this proposal. There do not appear to be any conflicts with existing electrical
utilities at this location. A three phase overhead electrical power line runs along the north side of the
property across the alley. Service is already provided to the existing building. Contact Entergy in
advance to discuss electrical service requirements, or adjustments to existing facilities (if any) as this
project proceeds.
■ Calhoun Short -form PD-R — 4208 Fairview Road — Z-9321
Entergy does not object to this proposal. There do not appear to be any conflicts with existing electrical
utilities at this location. Service is already provided via an underground service line to the existing
building. Contact Entergy in advance to discuss electrical service requirements, or adjustments to
existing facilities (if any) as this project proceeds.
■ Akins Subdivision Site Plan Review — 4008 Frazier Pike College Sta. — S-1815
Entergy does not object to this proposal. There do not appear to be any conflicts with existing electrical
utilities at this location. Service is already provided via an overhead service line to the existing building.
Contact Entergy in advance to discuss electrical service requirements, or adjustments to existing facilities
(if any) as this project proceeds.
• 4624 Willow Springs Rd Subdivision Site Plan Review — 4624 Willow Springs Rd — S-1814
This location is not within Entergy's allocated service territory and believes that it is served by ls` Electric
Cooperative..
Giving in Kindness in AR Subdivision Site Plan Review — 5816 Geyer Springs Rd. — S-1813
Entergy does not object to this proposal. There do not appear to be any conflicts with existing electrical
utilities at this location. Service is already provided via an underground service line to the existing
buildings. An overhead power line, pole and transformer exists on the south side of the property. Contact
Entergy in advance to discuss electrical service requirements, or adjustments to existing facilities (if any)
as this project proceeds.
• Rowanwood Subdivision Site Plan Review — E side of So. Shackleford in 2700-3300 Block — S-1812
Entergy does not object to this proposal. There do not appear to be any conflicts with existing electrical
utilities at this location. A three phase overhead electrical power line runs along the west side of
Shackelford Road just to the south of this project, and another one exists on Aldersgate Road just to the
east of the project. Contact Entergy in advance to discuss electrical service requirements, or adjustments
to existing facilities (if any) as this project proceeds.
LaMarche Village Preliminary Plat —16307 Taylor Loop Rd. — S-1811
Entergy does not object to this proposal. There are existing overhead, primary electrical facilities located
on this property which will need to be removed prior to the development. A three phase overhead
electrical power line runs along the south side of Taylor Loop Road to the north of this property. Contact
Entergy in advance to discuss electrical service requirements and adjustments to existing facilities as this
project proceeds.
If you need further assistance you may call me at 501-954-5158 or e-mail me at bneumei@entergy.com.
Sincerely,
��y cg�lL� .�LI�TlrCtl�
Bernard Neumeier, P.E.
Region Engineering Supervisor
Entergy Arkansas, Inc.
Little Rock Water Reclamation Authority Comments
Project Number 5-1811
Project Name Project Type
LaMarche Village Preliminary Plat
Project Number S-1812
Project Name Project Type
Rowanwood Subdiv Site Multi Bldg site Plan Review
Plan
Project Number S-1813
Comment Made
Sewer main extension required with easements if new
sewer service is required for this project.
Comment Made
Sewer main extension required with easements if new
sewer service is required for this project. Capacity Fee
Analysis required.
Project Name
Project Type
Comment Made
Giving Kindness in
Multi Bldg site Plan Review
Outside Service Boundary - No Comment.
Arkansas
Project Number 5-1814
Project Name
Project Type
Comment Made
4624 Willow Springs Road
Subdiv/Site Plan Review
Outside Service Boundary - No Comment.
Subdiv
Project Number 5-1815
Project Name
Project Type
Comment Made
Akins Subdivision
Subdiv/Site Plan Review
Sewer Available to this site.
Project Number Z-5309-A
Project Name
Project Type
Comment Made
Kavanaugh PCD
Planned Development: Commercial
Sewer Available to this site. EAD Review required if
food service on site
Project Number Z-6178-K
Project Name
Project Type
Comment Made
Stagecoach Village Lot 1
Planned Development: Office
Sewer Available to this site. EAD Review required if
food service on site
Project Number Z-8278-A
Project Name Project Type Comment Made
The District at Modtown Planned Development: Commercial Sewer available. Capacity fee analysis required for
hotels. EAD review required for food service.
Monday, April 16, 2018 Page 1 of 2
James, Donna
From:
Rhodes, Tony
Sent:
Tuesday, April 17, 2018 9:38 AM
To:
James, Donna
Cc:
Hogue, John; Salaam, Naim; Ingram, Derek
Subject:
Fire Department Zoning Comments
Comment for the following Locations:
Z-8278-A- 600 South University Avenue-NWC of University Avenue and
1-630
Full Plan Review
Z-5309-A- 2712 Kavanaugh Boulevard and 703 Beachwood Street
Full Plan Review
Z-6178-K- 9222 Stagecoach Road
Full Plan Review
Z-9319- 9601 Colonel Glenn Road
Full Plan Review
Z-9320- 6400 West Markham Stre
Streets
Full Plan Review
Z-9322- 15901 Ta for Loop Road
Full Plan Review
Z-9323- 818 West Capitol
NWC Markham and McKinle
1
Fire Apparatus Access Roads shall conform to all the requirements of Chapter 5 and Appendix D of the 2012
Arkansas Fire Prevention Code, Vol. 1. Specifically addressed are required access, construction & design
specifications, access road gates, signs, driveway widths of structures with hydrants, aerial fire apparatus access
roads, aerial fire apparatus roads distance to structure, fire lane markings, commercial & industrial
developments, and residential developments. Locations and extent of fire lane markings must be approved by
the fire code official and is subject to change at any time upon field evaluation. Contact Capt. Tony Rhodes at
(501) 918-3757.
Addresses
Addresses shall be posted in a conspicuous place during construction and when construction is complete as per
Little Rock City Ordinance Section 30-346 and Section 505 of the 2012 Arkansas Fire Prevention Code, Vol. 1
to facilitate emergency response. Numbers/Letters shall be Arabic numbers or alphabetic letters to be minimum
6" in height, of a durable, reflective material on a color contrasting background to promote enhanced
visibility. The numbers hall be in a conspicuously placed immediately above, on or at the side of the proper
door of each building so that the number can be seen plainly from the street on which the number is
based. Whenever any building is situated so that the number is not clearly discernible from the street line or
vision of the building from the street is otherwise obscured, the number or numbers assigned shall be placed
near the walk, driveway or common entrance to such buildings, and affixed upon a gate post, fence, mailbox,
post, or other appropriate place so as to be easily discernible (this is in addition to the numbers/letters on the
building). Numbers painted or stenciled on the curb shall not be a lawful substitute for the display of address
numbers prescribed by this article. Subject to change upon field evaluation. Contact Capt. Tony Rhodes at
(501) 918-3757.
Fire Hydrant
The Little Rock Fire Department, Capt. Tony Rhodes (501) 918-3757, needs to evaluate this site to determine
whether additional public and/or private fire hydrants will be required. The installation of any new fire
protection facilities will be at the expense of the project developer. Contact Central Arkansas Water regarding
procedures for installation of the hydrant(s). Subject to change at any time upon field evaluation.
S-1813-5816 Geyer Springs
Full Plans Review
Access roads
Fire Apparatus Access Roads shall conform to all the requirements of Chapter 5 and Appendix D of the 2012
Arkansas Fire Prevention Code, Vol. 1. Specifically addressed are required access, construction & design
specifications, access road gates, signs, driveway widths of structures with hydrants, aerial fire apparatus access
roads, aerial fire apparatus roads distance to structure, fire lane markings, commercial & industrial
developments, and residential developments. Locations and extent of fire lane markings must be approved by
the fire code official and is subject to change at any time upon field evaluation. Contact Capt. Tony Rhodes at
(501) 918-3757.
Addresses
Addresses shall be posted in a conspicuous place during construction and when construction is complete as per
Little Rock City Ordinance Section 30-346 and Section 505 of the 2012 Arkansas Fire Prevention Code, Vol. 1
to facilitate emergency response. Numbers/Letters shall be Arabic numbers or alphabetic letters to be minimum
6" in height, of a durable, reflective material on a color contrasting background to promote enhanced
visibility. The numbers hall be in a conspicuously placed immediately above, on or at the side of the proper
door of each building so that the number can be seen plainly from the street on which the number is
based. Whenever any building is situated so that the number is not clearly discernible from the street line or
vision of the building from the street is otherwise obscured, the number or numbers assigned shall be placed
near the walk, driveway or common entrance to such buildings, and affixed upon a gate post, fence, mailbox,
post, or other appropriate place so as to be easily discernible (this is in addition to the numbers/letters on the
3
developments, and residential developments. Locations and extent of fire lane markings must be approved by
the fire code official and is subject to change at any time upon field evaluation. Contact Capt. Tony Rhodes at
(501) 918-3757.
Addresses
Addresses shall be posted in a conspicuous place during construction and when construction is complete as per
Little Rock City Ordinance Section 30-346 and Section 505 of the 2012 Arkansas Fire Prevention Code, Vol. 1
to facilitate emergency response. Numbers/Letters shall be Arabic numbers or alphabetic letters to be minimum
6" in height, of a durable, reflective material on a color contrasting background to promote enhanced
visibility. The numbers hall be in a conspicuously placed immediately above, on or at the side of the proper
door of each building so that the number can be seen plainly from the street on which the number is
based. Whenever any building is situated so that the number is not clearly discernible from the street line or
vision of the building from the street is otherwise obscured, the number or numbers assigned shall be placed
near the walk, driveway or common entrance to such buildings, and affixed upon a gate post, fence, mailbox,
post, or other appropriate place so as to be easily discernible (this is in addition to the numbers/letters on the
building). Numbers painted or stenciled on the curb shall not be a lawful substitute for the display of address
numbers prescribed by this article. Subject to change upon field evaluation. Contact Capt. Tony Rhodes at
(501) 918-3757.
Fire Hydrant
The Little Rock Fire Department, Capt. Tony Rhodes (501) 918-3757, needs to evaluate this site to determine
whether additional public and/or private fire hydrants will be required. The installation of any new fire
protection facilities will be at the expense of the project developer. Contact Central Arkansas Water regarding
procedures for installation of the hydrant(s). Subject to change at any time upon field evaluation.