Loading...
HomeMy WebLinkAboutResponse to Comments 082323City of Little Rock Planning and Development Planning Commission Hearing/September 14, 2023 Applicant Comments for Proposed Development RE: Hamilton Station Phase 2 – Revised PCD (Z-7500-J) North of 14524 Cantrell Road DEVELOPMENT STAFF COMMENTS: 1.Provide detailed traffic study for proposed development. See attached. 2.Provide N/S and E/W cross sections through the property, showing proposed development. See attached. 3.Will Phase II be developed in more than one phase? Yes, Building A will be built at first and the remainder of the buildings will be built to meet market demand. 4.Provide building elevations. See attached. 5.Provide proposed uses for building “A”. Mini storage / Office warehouse 6.Provide building height for all buildings. BLDG A = 50’ BLDG B, C, D, F = 25’ 7.Clearly label floodway line and 25-foot floodway setback line. See revised site plan. 8.Dumpster area must be screened and comply with Section 36-523 of the City’s Zoning Ordinance. Will comply 9.All signage must comply with Section 36-555 of the City’s Zoning Ordinance (signs permitted in commercial zoning) Will comply 10. Any site lighting must be low-level and directed away from adjacent properties. Will comply CAW REVIEW COMMENTS: All Central Arkansas Water requirements in effect at the time of request for water service must be met. Permanent structures of any kind shall not be built inside the existing easement for the Central Arkansas Water RAW Water mains. There shall be a minimum of 5’ of separation between any proposed structures or utilities and the Central Arkansas Water RAW Water mains. Any and all proposed grade work inside the Easement for the Central Arkansas Water RAW Water mains shall be reviewed by Central Arkansas Water’s Engineering Department prior to construction. The Little Rock Fire Department needs to evaluate this site to determine whether additional public and/or private fire hydrant(s) will be required. If additional fire hydrant(s) are required, they will be installed at the Developer's expense. Please submit plans for water facilities and/or fire protection system to Central Arkansas Water for review. Plan revisions may be required after additional review. Contact Central Arkansas Water regarding procedures for installation of water facilities and/or fire service. Approval of plans by the Arkansas Department of Health Engineering Division and Little Rock Fire Department is required. A Capital Investment Charge based on the size of meter connection(s) will apply to this project in addition to normal charges. This fee will apply to all connections including metered connections off the private fire system. If there are facilities that need to be adjusted and/or relocated, contact Central Arkansas Water. That work would be done at the expense of the developer. Contact Central Arkansas Water regarding the size and location of the water meter. The facilities on-site will be private. When meters are planned off private lines, private facilities shall be installed to Central Arkansas Water's material and construction specifications and installation will be inspected by an engineer, licensed to practice in the State of Arkansas. Execution of Customer Owned Line Agreement is required. Due to the nature of this facility, installation of an approved reduced pressure zone backflow preventer assembly (RPZ) is required on the domestic water service. This assembly must be installed prior to the first point of use. Central Arkansas Water (CAW) requires that upon installation of the RPZA, successful tests of the assembly must be completed by a Certified Assembly Tester licensed by the State of Arkansas and approved by CAW. The test results must be sent to CAW's Cross Connection Section within ten days of installation and annually thereafter. Contact the Cross Connection Section at 377-1226 if you would like to discuss backflow prevention requirements for this project. Fire sprinkler systems which do not contain additives such as antifreeze shall be isolated with a double detector check valve assembly. If additives are used, a reduced pressure zone backflow preventer shall be required. We will comply with all CAW comments. LANDSCAPE REVIEW COMMENTS: 1. Any new site development must comply with the City’s minimal landscape and buffer ordinance requirements. Refer to the Code of Ordinances, Chapter 15 - Landscaping and Tree Protection, and Chapter 36, Article IX – Buffers and Screening. Will comply. LRWRA REVIEW COMMENTS: 10. Z-7500-J – Submit storm drainage and utility plans showing existing wastewater infrastructure plans to LRWRA so that we can ensure proper clearance for our existing sewer lines on the property. We will comply prior to construction. LRFD REVIEW COMMENTS: Fire Hydrants. Maintain fire apparatus access roads at fire hydrant locations as per Appendix D of the 2021 Arkansas Fire Prevention Code Vol. 1 Section D103.1 Access road width with a hydrant. Where a fire hydrant is located on a fire apparatus access road, the minimum road width shall be 26 feet, exclusive of shoulders. Grade Maintain fire apparatus access roads as per Appendix D of the 2021 Arkansas Fire Prevention Code Vol. 1 Section D103.2 Grade. Fire apparatus access roads shall not exceed 10 percent in grade except as approved by the fire chief. If the grade exceeds 10 percent, approval will be denied and the applicant must submit request to be reviewed by Fire Chief for Approval. Loading Maintain fire apparatus access road design as per Appendix D of the 2021 Arkansas Fire Prevention Code Vol. 1 Section D102.1 Access and loading. Facilities, buildings or portions of buildings hereafter constructed shall be accessible to fire department apparatus by way of an approved fire apparatus access road with an asphalt, concrete or other approved driving surface capable of supporting the imposed load of fire apparatus weighing at least 75,000 pounds. Commercial and Industrial Developments – 2 means of access. - Maintain fire apparatus access roads as per Appendix D of the 2021 Arkansas Fire Prevention Code Vol. 1 Section D104.1 Buildings exceeding three stories or 30 feet in height. Building or facilities exceeding 30 feet or three stories in height shall have at least two means of fire apparatus access for each structure. Section D104.2 Building exceeding 62,000 square feet in area. Buildings or facilities having a gross building area of more than 62,000 square feet shall be provide with two separate and approved fire apparatus access roads. Exception: Projects having a gross building area of up to 124,000 square feet that have a single approved fire apparatus access road when all building are equipped throughout with approved automatic sprinkler systems. D104.3 Remoteness. Where two fire apparatus access roads are required, they shall be placed a distance apart equal to not less than one half of the length of the maximum overall diagonal dimension of the lot or area to be served, measured in a straight line between accesses. 30’ Tall Buildings - Maintain aerial fire apparatus access roads as per Appendix D of the 2021 Arkansas Fire Prevention Code Vol. 1 Section D105.1 – D105.4 D105.1 Where Required. Where the vertical distance between the grade plane and the highest roof surface exceed 30’, approved aerial fire apparatus access roads shall be provided. For the purposes of this section the highest roof surfaces shall be determined by measurement to the eave of a pitched roof, the intersection of a roof to the exterior wall, or the top of the parapet walls, whichever is greater. D105.2 Width. Aerial fire apparatus access roads shall have a minimum unobstructed with of 26’, exclusive of shoulders, in the immediate vicinity of the building or portion thereof. D105.3 Proximity to building. At least one of the required access routes meeting this condition shall be located within a minimum of 15 feet and a maximum of 30 feet from the building, and shall be positioned parallel to one entire side of the building. The side of the building on which the aerial fire apparatus access road is positioned shall be approved by the fire code official. D105.4 Obstructions. Overhead utility and power lines shall not be located over the aerial fire apparatus access road or between the aerial fire apparatus road and the building. Other obstructions shall be permitted to be places with the approval of the fire code official. Dead Ends. Maintain fire apparatus access roads at dead end locations as per Appendix D of the 2021 Arkansas Fire Prevention Code Vol. 1 Section D103.4 Dead Ends. Dead-end fire apparatus access roads in excess of 150 feet shall be provided with width and turnaround provisions in accordance with Table D103.4. Requirements for Dead-end fire apparatus access roads. We will comply with all fire codes. BUILDING "A"3 STORY STORAGE15,300 S.F./ FLR.21 PARKING SPACES45,900 S.F. TOTALS1° 52' 31"W 586.80'PROJECT SITEArea : 10.63 ACS11° 36' 4 7 " E 1 3 4 . 4 9 ' S 4 0 ° 0 5 ' 0 5 "W 1 7 6 . 2 2 'S62° 53 ' 31 "W 172 .92 'N88° 39' 29"W 112.87'S16° 10' 2 8 " E 5 2 . 9 4 'N88° 28' 52"W 224.54'N89° 03' 33"E 20.18'N1° 42' 30"E 70.77'S66° 07' 12"E 107.85'S89° 30' 16"E 175.71'S81° 21' 32"E 134.30'S45° 40' 33"E 190.73'BOAT/RV STORAGE "F"9,500 S.F.BUILDING "B"STORAGE12,350 S.F.MINI STORAGE93,900 S.F.21 PARKING SPACESOPEN PARKING161412BUILDING "C"STORAGE9,100 S.F.BUILDING "D"STORAGE11,050 S.F.BOAT/RV STORAGE "E"6,000 S.F.16161515159OPEN PARKINGNEIGHBORHOOD RETAIL/OFFICE40,000 S.F.158 PARKING SPACES3.95 SPACES/1000 S.F.i i ffrGG.ESSENo.17170Jn ivDRAFTThis document ispreliminary innature and is not afinal signed andsealed document.HAMILTON STATION NEAR 14524 HWY 10 - LITTLE ROCK, AR REES COMMERCIAL NO T F O R C O N S R T U C T I O N SITE PLAN REVIEW PROJECT CONTACT INFORMATION:OWNER /DEVELOPER: REES COMMERCIAL11719 HINSON ROAD, SUITE 130LITTLE ROCK, ARKANSAS 72212 PHONE: (501) 223-9298CIVIL ENGINEER:JESS GRIFFIN PE CFM5 KINGSTON DRIVELITTLE ROCK, AR 72227 PHONE: (501) 690-3456ARCHITECT: ROARK PERKINS PERRY YELVINGTONARCHITECTURE & INTERIOR DESIGN713 W SECOND STREETLITTLE ROCK, ARKANSAS 72201 PHONE: (501) 372-0272LANDSCAPE ARCHITECT:FRANK RIGGINS, ASLAPHONE: (501) 554-2509PROPOSEDEXISTINGDESCRIPTIONSANITARY SEWER LINEFIBER OPTIC LINEOVERHEAD ELECTRIC LINEGAS LINEWATER LINEUNDERGROUND PHONE LINEUNDERGROUND ELECTRIC LINESTORM DRAINAGE PIPEGUY ANCHORFIRE HYDRANTWATER VALVEWATER METERUTILITY POLELIGHT POLESANITARY SEWER MANHOLESANITARY SEWER CLEAN-OUTTELEPHONE PEDESTAL/RISERSIGNELECTRICAL BOXAIR RELEASE VALVEDITCH FLOW LINEGAS REGULATORGAS METERCONTROL POINTCURB INLET/JUNCTION BOXORCATV CABLE LINEFENCEX-XDRAINAGE STRUCTURE - NO.LEGENDFHCOSFHCOPINNACLE STATIONSHOPPING CENTERSBUILDING MATERIALS - BRICK, STONE, GLASS, METAL AT REARMAX BUILDING HEIGHT = 65'DETENTION WILL BE PROVIDED UNDERGROUND CULVERTS.JESS GRIFFIN, PE5 KINGSTON DRIVELITTLE ROCK, AR 72227TEL (501) 690-3456JGGRIFFINPE@GMAIL.COM100 YR FLOODPLAIN14710 CANTRELLSHOPPING CENTEREXISTING SEWER MAINPHASE LINE (TYP.)PARKING / STORAGEDETENTION SYSTEM FLOODWAY25' FLOOD ESMTFLOODPLAIN FLOODWAYPINNACLE STATIONSHOPPING CENTER0+00 1+00 2+00 3+00 3+92 STA. 0+00.00BEGIN NORTHEAST CROSS-SECTIONEND NORTHEAST CROSS-SECTIONSTA. 4+12.540+001+002+003+004+004+13NO T F O R C O N S R T U C T I O NCODRAFTThis document ispreliminary innature and is not afinal signed andsealed document.CROSS-SECTION PLAN HAMILTON STATION NEAR 14524 HWY 10 - LITTLE ROCK, AR REES COMMERCIAL NO T F O R C O N S R T U C T I O N JESS GRIFFIN, PE5 KINGSTON DRIVELITTLE ROCK, AR 72227TEL (501) 690-3456JGGRIFFINPE@GMAIL.COM NORTHEAST CROSS-SECTIONHOR. SCALE: 1"=20'VERT. SCALE: 1"=10'280290300310320330340350360370280285290295300305310315320325330335340345350355360365370375WEST CROSS-SECTIONHOR. SCALE: 1"=20'VERT. SCALE: 1"=10'280290300310320330340280285290295300305310315320325330335340DRAFTThis document ispreliminary innature and is not afinal signed andsealed document.CROSS-SECTION PLAN HAMILTON STATION NEAR 14524 HWY 10 - LITTLE ROCK, AR REES COMMERCIAL NO T F O R C O N S R T U C T I O N JESS GRIFFIN, PE5 KINGSTON DRIVELITTLE ROCK, AR 72227TEL (501) 690-3456JGGRIFFINPE@GMAIL.COM