Loading...
HomeMy WebLinkAboutZ-8117-A Map 5DEVELOPER NOT TO RAISE GRMES IN FLOODWAY Concrete oProD REMOVE EXISTING CONCRETE BLOCK WALL REMOVE EXISTING HOUSE, CONCRETE SIDEWALK, & CONCRETE PATIO Vf REMOVE EXISTING ASPHALT PAVEMENT TO PROPERTY LINE PARTIAL EXISTING SITE SURVEY / DEMOLITION PLAN SCALE 1"=20'-0" NEW CONCRETE ENTRANCE SLAB EXISTING ENTRANCE DRIVEWAr TO REMAIN SITE LAYOUT SCALE 1"=20'-0" NOTES: 1. ALL DIMENSIONS ARE TO BACK OF CURB 2.8 TOTAL PARKING SPACES ARE PROVIDED (1 ADA ACCESSIBLE PARKING SPACE) 3. ALL SETBACKS SHALL MEET CITY OF LITTLE ROCK REQUIREMENTS. 4. DAMAGE TO PUBLIC AND PRIVATE PROPERTY DUE TO HAULING OPERATION OF CONSTRUCTION RELATED EQUIPMENT FROM A CONSTRUCTION SITE SHALL BE REPARIED BY THE RESPONSIBLE PARTY PRIOR TO THE ISSUANCE OF A CERTIFICATE OF OCCUPANCY. 5. REPAIR, REPLACE, OR EXTEND EXISTING DAMAGE OR MISSING CURB & GUTTER, SIDEWALK RAMPS OR CONCRETE APRONS WITHIN THE PUBLIC RIGHT-OF-WAY ADJACENT TO THE SITE. REMOVE ABANDONED DRIVEWAY CUTS AND INSTALL CURB, GUTTER, AND SIDEWALK ALL WORK WITHIN THE PUBLIC RIGHT-OF-WAY SHALL CONFORM TO CITY OF CONWAY STANDARD DETAILS AND ADA GUIDELINES. 6. OBTAIN PERMITS PRIOR TO DOING ANY STREET CUTS OR CURB CUTS. OBTAIN BARRICADE PERMIT PRIOR TO DOING ANY WORK IN THE RIGHT-OF-WAY. CONTACT CITY OF LITTLE ROCK TRAFFIC ENGINEERING FOR MORE INFORMATION. 7. ALL SIGNAGE, PAVEMENT MARKINGS AND PARKING LOT STRIPING SHALL CONFORM TO REQUIRMENTS GIVEN IN MANUAL OF UNIFORM TRAFFIC CONTROL DEVICES (MUTCD)_ MUTCD REQUIRES THAT PARKIMG SPACES BE MARKED IN WHITE. CONTACT CITY OF LITTLE ROCK TRAFFIC ENGINEERING WITH ANY QUESTIONS REGARDING STRIPING. 20 10 0 N Know what's below. Call before you dig. 20 40FT SCALE: 1"= 20' SIDEWALK OR FIN. GRADE CONCRETE IY61.11 SIGN POST W ACCESSIBILITY SYMBOL 8 WAN ACCESSIBLE' SIGN MOUNTED BELOW (VAN ACCESSIBLE SIGN NOT NUTAND LOCK WASHER SCREW OR BOLT MOUNTING SITE GRADING PLAN SCALE V=20' -O" PARKING ONLY PARTIAL ELEVATION EDGE OF WALK (AGAINST LANDSCAPE OR BUILDING TYP ) RECD. WI MW B STRIPED AISLE) FACE OF WALK ACCESSIBLE 4 L&FT'U' CHANNEL (GALVANIZED) Ww i� RAMP. SEE DETAIL IoUwE{ m]U az ^I0 6 `nl s@J L 10 31rz•-J POST SECTION SIGN POST W ACCESSIBILITY SYMBOL 8 WAN ACCESSIBLE' SIGN MOUNTED BELOW (VAN ACCESSIBLE SIGN NOT NUTAND LOCK WASHER SCREW OR BOLT MOUNTING SITE GRADING PLAN SCALE V=20' -O" PARKING ONLY PARTIAL ELEVATION EDGE OF WALK (AGAINST LANDSCAPE OR BUILDING TYP ) RECD. WI MW B STRIPED AISLE) FACE OF WALK ACCESSIBLE RAMP. SEE DETAIL WHEELSTOP SEE OETAK (REC'D- IF WALT( WIDTH IS LESS TI W! rff) Q 0 PAINTED STRIPING '-S' O.C. AT J FRONT. OF RAMP M1MITE REFLECTIVE) E N 11 sn PAVEMENT MAX SLOPE 2% IN 1 ALL DIRECTIONS. 9.009.00' 9.00' II ACCESSIBLE PARKING STALLS OR CURB EDGE OF RAMP TO BE FLUSH WITH PARKING LOT SURFACE W RAMP UP TO IEWALK UTILITIES SANITARY SEWER: LITTLE ROCK WASTEWATER 501-688-1452 (ENGINEERING) 501-223-1509 (EMERGENCY) WATER: CENTRAL ARKANSAS WATER 221 EAST CAPITOL LITTLE ROCK, ARKANSAS 501-372-5161 ELECTRIC: ENTERGY ARKANSAS, INC. 425 WEST CAPITOL AVENUE LITTLE ROCK, ARKANSAS 501-377-4000 NATURAL GAS: CENTERPOINT ENERGY 400 WEST CAPITOL #600 LITTLE ROCK, ARKANSAS 888-498-0409 2" OF HMAC TYPE 3 SURFACE COURSE CONFORMING TO SECTION 407 OF THE ARKANSAS HIGHWAY AND TRANSPORTATION DEPARTMENT (AHTD) STANDARD SPECIFICATIONS FOR HIGHWAY CONSTRUCTION, 1996 OR 2003 EDITION O 6" THICK CLASS 7 (SB -2) CRUSHED — STONE COMPACTED TO 95% STANDARD PROCTORDENSITY CONFORMING TO SECTION 303 OF THE (AHTD) STANDARD SPECIFICATIONS FOR HIGHWAY CONSTN V THICK OF EXISTING SUBGRADE — SCARIFIED AND RECOMPACTED TO 90% OF MODIFIED PROCTOR DENSITY O MATCH TOP OF NEW PAVEMENT WITH EXISTING GRADES MASS PLANTINI ANDORRAJUNI Z-6" O.C. TYPIC ALL FRONT YARD SHRU MUST BE 36` MINIMUM k F,T INSTALLATION 24" BERM AND 36" PLANT yr MATERIALS THAT WILL BE INSTALLED AND MAINTAINED AT AT A MINIMUM OF 42" IN HEIGHT SITE LANDSCAPING PLAN SCALE: 1"=20'-0" 1. ALL LANDSCAPING SHALL COMPLY WITH CITY OF LITTLE ROCK LANDSCAPING ORDINANCE (Sec. 15100) AND ZONING REGULATIONS. 2. ALL LANDSCAPED AREAS OF THE SITE SHALL BE CONSTRUCTED WITH AN AUTOMATIC SPRINKLER IRRIGATION SYSTEM AS PART OF THE LANDSCAPING SUBCONTRACT. IRRIGATION TO COVER 100% OF ALL LANDSCAPING AREA. 3. ALL SITE PERIMETER TREES SHALL PROVIDE AN (8) EIGHT FOOT HEIGHT CLIMB CLEARANCE EXCEPT MULTI -TRUNK SPECIES, WHICH SHALL BE INSTALLED AND MAINTAINED AS NOT TO CREATE OBSTRUCTIONS TO VEHICULAR OR PEDESTRIAN TRAFFIC, 4. GENERAL CONTRACTOR SHALL PROVIDE SCHEDULE 40 PVC SLEEVING 4" OR 6" UNDER ALL DRIVES AND PAVED AREAS FOR IRRIGATION PIPING. SLEEVING SHALL BE BURIED A MINIMUM OF 18" BELOW GRADE AND THE ENDS OF THE SLEEVES CLEARLY MARKED BY THE GENERAL CONTRACTOR AND SHALL EXTEND OUT A MINIMUM OF 18" PAST ANY CURB OR PAVING. 5. PROVIDE MULCH AND EDGING IN ISLANDS AND AROUND BASE OF ALL LANDSCAPED AREAS AROUND NEW PARKING LOT PERIMETER. 6. THE CITY BEAUTIFUL COMMISSION RECOMMENDS PRESERVING AS MANY EXISTING TREES AS FEASIBLE ON THIS SITE. CREDIT TOWARD FULFILLING LANDSCAPE ORDINANCE REQUIREMENTS CAN BE GIVEN WHEN PRESERVING TREES OF 6 INCH CALIPER OR LARGER LANDSCAPING LEGEND 0 WILLOW OAK (5 TOTAL) 2` MIN. CALIPER "`MM 1111111 trrr CHINESE PISTACHE (7 TOTAL)�.�� F AUT 2' MIN CALIPER Lu: PHILLIP LENS •'�' O = U: ENGINEERING. INC. SWEET BAY MAGNOLIA (6 TOTAL) • z • 2" MIN CALIPER No. 566 -v, S Et4­w O SWEET BAY MAGNOLIA �r`rlln nnMMl```� 2" MIN CALIPER O CLARA INDIAN HAWTHORN (36 TOTAL) 36" HT MIN AT INSTALLATION • KNOCK OUT ROSE (28 TOTAL) ,b•,G • 36" HT MIN AT INSTALLATION I'n O^,w'EMERALD GREEN ARBORVITAE CZ) 2• MIN CALIPER & 5R. HT MIN AT INSTALLATION -Z SOLID SOD (/'y 419 HYBRID BERMUDA LANDSCAPING CALCULATIONS HMAC ASPHALT SURFACE COURSE NOT TO SCALE 1. 6,105 SF TOTAL PAVEMENTIWALKS/BUILDINGS. 2. 6,105 SF x 8% = 488 SF OF INTERIOR LANDSCAPEIGREEN SPACE REQUIRED, 3. WATER SOURCE WILL BE PROVIDED WITHIN 75 FEET OF ALL LANDSCAPED AREAS. 1 1 I U z wr4 zw 1—I W� U �P4 a.1 U, a> ■ O 0 W U Uj i0/,'ST�ATE �OF ARKANSAS_ REGISTEFWE PROFESSI'AL ErG-�ER 0 c PROJECT NUMBER: SHEET ISSUE DATE: 8-16-16 TITLE: SITE PLAN SHEET NUMBER: C1.1