HomeMy WebLinkAboutZ-8110 Staff AnalysisSEPTEMBER 25, 2006
ITEM NO.: 8
File No.: Z-8110
Owner: J.M. D. Holdings Trust
Applicant: Eugene P. Levy
Address: 5400 Centerwood Road
Description: Lot 95 and Part of Lot 96, Prospect Terrace No. II Addition
Zoned: R-2
Variance Requested: Variances are requested from the area provisions of Sections
36-156 and 36-254, and the building line provisions of Section 31-12 to allow building
additions (principal and accessory) with reduced setbacks and increased coverage and
a building addition which crosses a platted building line.
Justification: The applicant's justification is presented in an attached letter.
Present Use of Property: Single Family Residence
Proposed Use of Property: Single Family Residence
STAFF REPORT
A. Public Works Issues:
No Comments
B. Staff Analysis:
The R-2 zoned property at 5400 Centerwood Road is occupied by a two-story
brick and frame single family residence located within the west half of the
property. There is a two-story brick and frame accessory garage structure at
the northwest corner of the property. A one -car wide driveway from
Centerwood Road is located at the southwest corner of the lot. The driveway
runs along the west side of the residence to the existing garage structure.
There is a 30 foot front platted building line on this R-2 zoned property. The
SEPTEMBER 25, 2006
ITEM NO.: 8 (CON'T.
porch and steps on front of the existing residence cross the platted building
line by approximately 8 feet.
The applicant proposes to construct a one-story addition on the rear of the
house and a two-story addition on the east side of the house, as noted on the
attached site plan. The addition will be located 8 feet from the east side
property line and 47 feet from the rear (north) property line. As part of the
proposed construction, the existing front porch and steps will be removed, with
a new covered porch and steps to be constructed with the new addition on the
east side of the house. The new porch will cross the front platted building line
by five (5) feet for a 25 foot front setback. The step portion will be located 21
feet back from the front property line (to the first step). There will also be a
small uncovered, unenclosed stoop/step structure on the east side of the new
addition for a side entry door. The stoop will be four (4) feet wide, with a four
(4) foot side setback.
The applicant is also proposing to construct a two-story addition to the existing
accessory garage building. The addition will maintain the existing one (1) foot
side (west) and two (2) foot rear (north) setbacks. With the addition, the
accessory building will cover approximately 39 percent of the required rear
yard (rear 25 feet of the lot). There will also be a covered porch and walkway
on the rear of the residence leading to the accessory garage structure.
Section 36-254(d)(1) of the City's Zoning Ordinance requires a minimum front
setback of 25 feet. Section 31-12( c) of the Subdivision Ordinance requires
that building line encroachments be reviewed and approved by the Board of
Adjustment. Additionally, Section 36-254(d)(2) requires a minimum side
setback of 8 feet. Section 36-156(a)(2)c. allows accessory structures to
occupy a maximum of 30 percent of the required rear yard. This section also
requires a 60 foot setback from a street fronting property line. Section 36-
156(a)(2)f. requires a minimum side setback of three (3) feet for accessory
structures. Therefore, the applicant is requesting variances from these
ordinance standards to allow the addition to the principal structure with
reduced front and side setbacks (front steps and side stoop) and to cross a
front platted building line, and the addition to the accessory garage structure to
have reduced side and rear setbacks and increased rear yard coverage.
The applicant has informed staff that garage doors are proposed on the north
side of the accessory building. Garage doors exist on the south side of the
structure. Given traffic concerns which have been raised in the past, regarding
safety issues along "O" Street adjacent to the elementary school, staff does
not support garage doors on the north side of the accessory building. The
accessory building is located only two (2) feet from the north property line.
There is not adequate space/site-distance for a vehicle to pull in or out of the
garage to/from "O" Street without safety concerns.
2
SEPTEMBER 25, 2006
ITEM NO.: 8 (CON'T.
Staff is supportive of the requested variances. Staff feels the proposed
additions will maintain the character of the neighborhood. Although several
variances are requested, they are very minor in nature. Given the fact that the
applicant has slightly over 1.5 platted lots, the overall massing of the structures
will be compatible with most of the other lots in this neighborhood. There will
be a large amount of yard space maintained. The front steps and the side
stoop are the only portions of the principal building addition which do not
conform to typical zoning ordinance setback criteria. The increase in size of
the accessory building will not be out of character with other large accessory
structures in the neighborhood. Staff believes the proposed building additions
with reduced setbacks and slightly increased rear yard coverage will have no
adverse impact on the adjacent properties or the general area.
If the Board approves the building line variance, the applicant will have to
complete a one -lot replat reflecting the change in the platted front building line
for the new porch/step structure. The applicant should review the filing
procedure with the Circuit Clerk's office to determine if the replat requires a
revised Bill of Assurance.
C. Staff Recommendation:
Staff recommends approval of the variances associated with the proposed
building additions, subject to the following conditions:
1. Completion of a one -lot replat reflecting the change in the front platted
building line as approved by the Board.
2. The additions must be constructed to match the existing structures.
3. The front step structure must remain uncovered and unenclosed.
4. The front porch structure must remain unenclosed.
5. The side stoop/step structure must remain uncovered and unenclosed.
6. The covered walkway must remain unenclosed.,
7. There are to be no garage doors on the north side of the accessory
garage building.
3
SEPTEMBER 25, 2006
ITEM NO.: 8 (CON'T_
BOARD OF ADJUSTMENT: (SEPTEMBER 25, 2006)
The applicant was present. There were no objectors present. Staff presented the item
and a recommendation of approval.
Staff noted that condition #7 would be eliminated from the "staff recommendation". Staff
explained that Public Works had visited the site and determined that there would be no
sight -distance problem with garage doors on the north side of the garage structure.
The applicant offered no additional comments.
The item was placed on the Consent Agenda and approved as recommended by staff
by a vote of 4 ayes, 0 nays and 1 open position.
0