HomeMy WebLinkAboutZ-8045 Map 11m ,i / GENERAL NOTES: ' , HENDE17SON SUBDIVISION � � l 1. BACKFLOW PREVENTION WILL BE PROVIDED IN ACCORDANCE WITH CENTRAL ARKANSAS WATER AND ARKANSAS DEPARTMENT OF HEALTH ONC MON REQUIREMENTS. 2. THE NUMBER OF FIRE HYDRANTS AND LOCATIONS WILL BE COORDINATED 1 2 LOT WITH FIRE DEPARTMENT. LOT 3. THE SUBJECT PROPERTY LIES WITHIN THE FLOODPLAIN, AND IS DESIGNATED ZONE X (AREAS DETERMINED TO BE OUTSIDE THE 500 YEAR FLOODPLAIN). AND ZONE AE (BASE FLOOD ELEVATIONS DETERMINED), ACCORDING TO FIRM PANEL */ 25p 0501810104-E, DATED OCTOBER 19, 2001. 4. BOUNDARY SURVEY WAS PERFORMED BY AMI ENGINEERING, INC., PLAT DATED 3-10-06. x E f'\ 251 �6 2 25z 25� 5. UTILITIES SHOWN ON THIS DRAWING WERE LOCATED BY TRANSCRIBING FROM 6 25� 255 RECORD MAPS. NO EXCAVATIONS WERE MADE TO CONFIRM SUB -SURFACE UTILITIES.25 NO GUARANTEE IS EXPRESSED OR IMPLIED THAT ALL UTILITIES HAVE BEEN SHOWN, 32 51 _ OR THAT THOSE SHOWN ARE FULLY ACCURATE. AR -- 252 �� 56 256_ 6. BUFFER AREAS SHALL BE LANDSCAPED IN ACCORDANCE WITH THE CITY OF LITTLE ROCK `�� �ZEg 252. — 256' SUBDIVISION & ZONING ORDINANCE SECTIONS 15-81 THROUGH 15-85 & CHAPTER 36, ARTICLE IX PNfl 11� J' 250 251 ._ 255 254.._=. E ____256 GENERATOR PAD 1 z / PROP & CPP 2 25a k ITY ADDITION PPgA SET ���� FUEL TANK PAD c o A LT)F�PMON ODOR CONTROL S I U rn � v PR BOLLARD —� (TYP) ` o.* NP v ^ 9 U P 5`b / gLOCK� ANDEDTR2 SIGN LOCATION o , POP ---00\A RN /`_Z PP 25.0' N 12'32'55" W� / LOT � LOT � 5� � 2 55 0'� S 60 - 0 3 i p C A � cn 0 1J RFBA SS 6 T �Z 3 LO S�R�i� P�OPO LOT N 6 255 / S 5 9 35 / 2 M 283 3 � 251 m v CONNECT j v NINE 7 PROPOSED 2 _ - OPER( J DGAP In SET KF_B K i OT 4 \ J %A i , 0 8' HIGH SECURITY FENCE AROUND PERIMETER /,-- 50'(MIN) LANDSCAPED BUFFER IN ACCORDANCE WITH THE CITY OF LITTLE ROCK SUBDIVISION & ZONING ORDINANCE 0 m 1 � I � m FLOW METER VAULT N 0 °D PUMP TEST VAULT Ln 55` a N SCALE IN FEET 15 0 30 CONFORMED PROJECT NO. 8521-47382 FILE NAME: PF -11 -PS -PL _CB02 a�� ®�®SSAr�'Op®�Cm AUANSAS ® REGISTERED PR®FESSIONAL < ENGINEER �C, No. ®® ®� ®� dG 701®®®® �m®c��® Camp Dres r &McKee Inc. -, • .RS Consu/ton s AMl Engineering - V Assoc o =s, -TD mOswold EngineeringCONTRACT Little Rock �� Wastewater PEAK FLOW ATTENUATION FACILITIES PUMP STATION, FORCE MAIN &EQUALIZATION BASIN II PEAK FLOW PUMP STATION OVERALL SITE PLAN I`w' S' % p07 SHEET N0. CB -2 rC� CONFORMED PROJECT NO. 8521-47382 FILE NAME: PF -11 -PS -PL _CB02 a�� ®�®SSAr�'Op®�Cm AUANSAS ® REGISTERED PR®FESSIONAL < ENGINEER �C, No. ®® ®� ®� dG 701®®®® �m®c��® Camp Dres r &McKee Inc. -, • .RS Consu/ton s AMl Engineering - V Assoc o =s, -TD mOswold EngineeringCONTRACT Little Rock �� Wastewater PEAK FLOW ATTENUATION FACILITIES PUMP STATION, FORCE MAIN &EQUALIZATION BASIN II PEAK FLOW PUMP STATION OVERALL SITE PLAN I`w' S' % p07 SHEET N0. CB -2 DESIGNED BY: M. CROW DRAWN BY: B. TAIL PLACIDOT4 SHEET cHK'D ev M. CROW cRoss cHK'o Br, A. BENZING APPROVED e C. JOHNSON DATE: JULY 2007 ONE INCH AT FULL SIZE IF NOT ONE INCH SCALE ACCORDINGLY ISSUED AS BID REV. N0. DATE DRWN CHKD REMARKS