HomeMy WebLinkAboutZ-6408-A Staff AnalysisJanuary 30, 2020
ITEM NO.: 5 FILE NO.:
NAME: St. Bartholomew Catholic Church Parish Hall —
Conditional Use Permit
LOCATION: 1622 Marshall Street
OWNER/APPLICANT: Catholic Diocese of Little Rock/Owner
Woods Group Architects/Applicant
PROPOSAL: A conditional use permit is requested to allow for
construction of a Parish Hall and a parking lot
adjacent to the existing church on this R-3 zoned
property.
STAFF ANALYSIS:
The property is located in the Central High Design Overlay District. It has been
determined that there is at least one variance form the DOD standards. As such,
the CUP application needs to be withdrawn and the item refiled as a Planned
Development. The applicant concurs.
STAFF RECOMMENDATION:
Staff recommends withdrawal of the conditional use application.
PLANNING COMMISSION ACTION: (JANUARY 30, 2020)
The applicant was not present. There were no other persons registered in
attendance. Staff presented the item and the recommendation of withdrawal.
There was no further discussion. The item was placed on the consent agenda
and approved for withdrawal. The vote was 10 ayes, 0 noes and 1 absent.
SUBDIVISION COMMITTEE COMMENTS
DECEMBER 23, 2019
ITEM NO.: 5. ST. BARTHOLOMEW CATHOLIC CHURCH PARISH HALL
CONDITIONAL USE PERMIT
1622 MARSHALL STREET (Z -6408-A)
Planning Staff Comments:
1. The plat/bill of assurance for Centennial Addition does not address use issues
2. Specify uses proposed for the building
3. Provide building height.
4. Provide signage plan
5. Locate and describe all proposed fencing
6. Locate dumpster and required screening
7. All site lighting is to be low-level and directional, shielded downward and into the site
8. The site is located in the Central High Design Overlay District and must comply with the
following criteria or the project must be refiled as a Planned Development rezoning:
a) Orientation. The primary fagade of a nonresidential building shall face the principal
street. The principal streets, as referred to in this section, shall refer to the street having
the highest classification according to the city master street plan. Buildings located on
corner lots shall have the same orientation as adjacent nonresidential structures.
b) Ground -level fagade. For new construction at least sixty (60) percent of the ground -floor
level facing pedestrian public circulation areas shall be glass windows and/or displays.
c) Nonresidential building setback. All commercially and office zoned properties within the
boundaries of the district shall have a ten -foot front setback with building sited at the
front setback property line. Properties on street corners shall be sited on the property
lines ten (10) feet off the property lines abutting the street corner. There shall be a five-
foot side yard setback from residentially zoned properties, zero -foot side yard setback
from non residentially zoned property and rear yard setback of twenty-five (25) feet.
d) Drive-through facilities. No drive-through facilities shall be permitted on front facades of
buildings. Buildings which are on a corner shall be considered to have two (2) front
facades. Drive-through facilities are permissible on side or rear facades.
e) Roofs. Flat roofs and pitched roofs are permitted. Rooflines should follow predominant
style of the adjacent buildings.
f) Materials. The materials of the exterior shell shall be brick, other masonry, wood, or a
material that resembles wood (i.e., vinyl siding, etc.)
g) Standard parking requirements. Parking requirements within the district shall be fifty
(50) percent of that required by article VIII.
h) Maximum parking. The maximum parking allowed shall be the minimum standard
established in article VIII.
ITEM NO.: 5 (CON'
-640
i) Parking facilities. Surface parking shall be limited to the side and rear of structures. No
parking shall be allowed in the front -yard setback. Parking structures shall have ground -
level uses devoted to non -vehicular activities. Development of ground -level retail or
office uses is encouraged.
Landscaping.
Trees greater than fourteen (14) inches in diameter, measured at four and one-half (4 '/z)
feet above the ground, shall be protected from removal and damages in future
development of the district. Any development within fifty (50) feet of any such tree shall be
reviewed prior to development to assure protective measures are included and in place.
Tree removal can only be done if approved by the city's urban forester. Penalties for
violations shall be listed in chapter [section] 1-9. For trees in the public right-of-way, see
section 15-51.
Variance/Waivers:
Y None requested.
Public Works:
1. A 20 feet radial dedication of right-of-way is required at the intersection of Marshall St. and
W. 16th St.
2. With issuance of a building permit, due to the existing damaged public infrastructure within
the right-of-way repair or replace any curb, gutter, sidewalk and access ramps that are
damaged and not in compliance with ADA recommendations in the public right-of-way prior
to occupancy.
3. Access is proposed off the rear alley, with the issuance of the building permit, the alley
should be repaved to at least 15 ft in width from W. 16th St. south to the proposed access
driveways.
4. Remove all existing curb cuts proposed not to be used with the development with the
issuance of the building permit.
5. A grading permit in accordance with section 29-186 (c) & (d) will be required prior to any
land clearing or grading activities at the site. Other than residential subdivisions, site
grading and drainage plans must be submitted and approved prior to the start of
construction.
6. Show proposed location of any gates and fencing associated with the parking lot.
7. Damage to public and private property due to hauling operations or operation of
construction related equipment from a nearby construction site shall be repaired by the
responsible party prior to issuance of a certificate of occupancy.
8.
Utilities and Fire Department/County Planning
Little Rock Water Reclamation Authority:
Sewer Available to this Site. FOG analysis required.
ITEM NO.: 5 (CON
Entergy:
-6408-A
Entergy does not object to this proposal. There does not appear to be any conflicts with
existing electrical utilities at this location. Contact Entergy in advance to discuss electrical
service requirements, or adjustments to existing facilities (if any) as this project proceeds.
Centerpoint Energy: No comment.
AT&T: No comments received.
Central Arkansas Water:
NO OBJECTIONS; All Central Arkansas Water requirements in effect at the time of request
for water service must be met.
Fire Department: No comment.
Building Codes: No comment.
County Planning: No comment received.
Rock Reaion METRO: No comment.
Planning Division: No comments.
Landscape:
1. Any new site development must comply with the City's minimal landscape and buffer
ordinance requirements.
2. The property is located in the City's designated mature area. A twenty-five (25%)
percent reduction of the buffer, perimeter planning bed widths, building, and interior
parking landscape requirements is acceptable.
3. Street buffers will be required at six (6) percent of the average depth of the lot. The
minimum dimension shall be one-half (Y2) the full width requirement but in no case less
than nine (9) feet or six (6) feet nine (9) inches in designated mature areas.
4. Eight percent (8%) of the vehicular use area must be designated for green space; this
green space needs to be evenly distributed throughout the parking area(s). The
minimum size of an interior landscape area shall be one hundred fifty (150) square feet
for developments with one hundred fifty (150) or fewer parking spaces. Interior islands
must be a minimum seven and one half (7 1/2) feet in width. Trees shall be included in
the interior landscape areas at the rate of one (1) tree for every twelve (12) parking
spaces.
ITEM NO.: 5 (CON'T) Z -6408-A
After twenty-five 25%percent reduction of the interior landscape requirements
the smallest acceptable interior landscape space would be 112 square feet in
area.
Interior landscape areas are deficient.
5. An irrigation system shall be required for developments of one (1) acre or larger. For
developments of less than one (1) acre a there shall be a water source within seventy-
five (75) feet of all plant material if an automatic irrigation system is not provided.
6. If any of the landscape code requirements cannot be met a variance from the City
Beautiful Commission may be required before a building permit is issued.
7. The City Beautiful Commission recommends preserving as many existing trees as
feasible on this site. Credit toward fulfilling Landscape Ordinance requirements can be
given when preserving trees of six (6) inch caliper or larger
Other: Submit responses to staff issues and four (4) copies of a revised site plan (if required) no
later than Wednesday, January 8, 2020. Required notice are to be sent via certified mail no later
than Wednesday, January 15, 2020. The City provided notices form must be used. Proof of
notices is to be provided to staff no later than January 24, 2020.