HomeMy WebLinkAboutZ-7952 Staff AnalysisILE NO.: Z-7
NAME: Pinnacle Valley Court Long -form PD -R
LOCATION: Located on Pinnacle Valley Road, just North of Cantrell Road
DEVELOPER:
St. Pat Properties, LLC
17 Portland Road
Little Rock, AR 72212
ENGINEER:
Central Arkansas Surveying
1012 Autumn Road
Little Rock, AR 72211
AREA: 6.93 acres
CURRENT ZONING:
ALLOWED USES:
PROPOSED ZONING:
PROPOSED USE:
NUMBER OF LOTS: 30 FT. NEW STREET: 973 LF
R-2, Single-family
Single-family residential
Single-family — Zero Lot Line Residential
VARIAN C ESNVAIVERS REQUESTED:
1. A variance to allow the placement of a six-foot privacy fence within the required
building setback along Pinnacle Valley Road.
2. A variance to allow a reduced terminus (65 -feet and 75 -feet) of two cul-de-sac
streets from the property line.
3. A variance to allow the development of double frontage lots.
4. A variance to allow a reduced setback adjacent to Pinnacle Valley Road.
A. PROPOSAL/REQUEST:
The applicant is proposing the development of this 6.93 -acre tract (303,177
square feet) with 30 single-family residential lots. The applicant has indicated 22
of the lots will be zero lot line single-family homes with the remaining 8 lots being
developed as typical R-2, Single-family zoned properties. The applicant has
indicated an average lot size of 7,663 square feet and the total green space
provided is 129,213 square feet or 42 percent of the development. The applicant
FILE NO.: Z-7952 (Cont.
has indicated the total proposed building footprint as 93,497 square feet. The
applicant has indicated a front building line of 15 -feet and a rear yard setback of
20 -feet along Pinnacle Valley Road. The applicant has indicated one side yard
setback of eight feet for the zero lot line lots to allow each lot outdoor living area.
The applicant has indicated Lots 2, 17, 25 — 30, the traditional single-family lots,
will have an eight foot side yard setback on each lot line.
The applicant is requesting a variance to allow the development of double
frontage lots for Lots 2 - 14. The applicant is also requesting a variance to allow
a reduced building line adjacent to an arterial street for Lots 2 — 14.
The applicant has set aside an area for detention along the southern portion of
the site. The applicant has also indicated dedication of right-of-way (45 -feet from
centerline) to meet the current Master Street Plan standard.
B. EXISTING CONDITIONS:
The site is wooded with varying degrees of slope. Pinnacle Valley Road is a
narrow two lane roadway with open ditches for drainage. There is a veterinary
clinic located to the south of the site on property zoned PD -O. The primary use
in the area 'is single-family. There is a new single-family subdivision currently
being developed to the northwest of the site.
C. NEIGHBORHOOD COMMENTS:
As of this writing, staff has received several informational phone calls from area
residents. The Westchester Neighborhood Association and the River Valley
Neighborhood Association, all property owners located within 200 -feet of the site
and all residents who could be identified located within 300 feet of the site were
notified of the public hearing.
D. ENGINEERING COMMENTS:
Public Works Conditions:
1. Pinnacle Valley Road is classified on the Master Street Plan as a minor
arterial. A dedication of right-of-way 45 feet from centerline will be required.
2. With site development, provide design of street conforming to the Master
Street Plan. Construct one-half street improvement to Pinnacle Valley Road
including 5 -foot sidewalks with planned development.
3. Storm water detention ordinance applies to this property. Show the
proposed location for storm water detention facilities on the plan.
4. Prepare a letter of pending development addressing streetlights as required
by Section 31-403 of the Little Rock code. Contact Traffic Engineering at
(501) 379-1813 (Steve Philpott) for more information regarding street light
requirements.
2
FILE NO.: Z-7952 (Cont.)
5. Obtain permits prior to doing any street cuts or curb cuts. Obtain barricade
permit prior to doing any work in the right-of-way. Contact Traffic Engineering
at (501) 379-1817 (Derrick Bergfield) for more information.
6. On site striping and signage plans should be forwarded to Public Works,
Traffic Engineering for approval with the site development package.
7. Proposed driveway location should be located at the crest of the hill to
alleviate site problems.
8. A grading permit in accordance with Section 29-186 (c) and (d) will be
required prior to any land clearing or grading activities at the site. Site
grading, and drainage plans will need to be submitted and approved prior to
the start of construction.
9. Obtain a NPDES storm water permit from the Arkansas Department of
Environmental Quality prior to the start of construction.
10. Street names and street naming conventions must be approved by Public
Works. Contact David Hathcock at (501) 371-4808.
11. Cul-de-sac should be designed with a right-of-way diameter of 100 ft and
pavement width diameter of 80 foot.
E. UTILITIES AND FIRE DEPARTMENT/COUNTY PLANNING:
Wastewater: Sewer main extension required, with easements, if service is
required for the project. Contact Little Rock Wastewater Utility at 688-1414 for
additional information.
Entergy: No comment received.
Center -Point Energy: No comment received.
SBC: No comment received.
Central Arkansas Water: All Central Arkansas Water requirements in effect at
the time of request for water service must be met. A Capital Investment Charge
based on the size of the meter connection(s) will apply to this project in addition
to normal charges. A water main extension will be required in order to provide
service to this property. This development will have minor impact on the existing
water distribution system. Proposed water facilities will be sized to provide
adequate pressure and fire protection.
Fire Department: Place fire hydrants per code. Contact the Little Rock Fire
Department at 918-3700 for additional information.
County Planning: No comment.
CATA: The site is not located on a dedicated CATA Bus Route.
3
FILE NO.: Z-7952 Cont.
F. ISSUES/TECHNICAL/DESIGN:
Planning Division: This request is located in the River Mountain Planning
District. The Land Use Plan shows Single Family with some Transition on the
southern portion. The applicant has applied for a Planned Development —
Residential for a residential development of 30 detached homes.
The request does not require a change to the Land Use Plan. The overall
density is less than what Single Family allows even though the development has
zero lot line homes in part of the development.
Master Street Plan: Pinnacle Valley Road is shown as a Minor Arterial on the
Master Street Plan and may require dedication of right-of-way and may require
street improvements since it is built to a two-lane section at this time.
Bicycle Plan: The closest bikeway is a Class One which is on Taylor Loop
Road/Rahling Road and is located about one-quarter mile to the west of the site.
A Class One bikeway is totally separated from the automobile lanes.
City Recognized Neighborhood Action Plan: The applicant's property lies in the
area covered by the River Mountain Neighborhood Action Plan. The Residential
Development goal lists objectives of "Develop Neo -traditional neighborhoods
(pedestrian and bicycle friendly, which are less dependant on automobiles) in
areas that have not yet been developed" and an action statement of "Enforce the
construction of sidewalks with all types of developments.". Additional action
statements are to "Require street lighting be in place in new subdivisions at the
time streets are opened" and to "Require developers to install underground
utilities in all new subdivisions."
Landscape: No comment.
G. SUBDIVISION COMMITTEE COMMENT: (October 20, 2005)
The applicant was present representing the request. Staff presented an
overview of the proposed request indicating there were additional items
necessary to complete the review process. Staff stated a 10 -foot restrictive
access easement would be required along the rear of the lots abutting Pinnacle
Valley Road. Staff also stated the site plan included a building footprint and the
maximum buildable area. Staff requested the applicant provide the maximum
buildable area only.
Public Works comments were addressed. Staff stated with the site development
street improvements to Pinnacle Valley Road would be required. Staff also
stated the proposed driveway location should be placed at the crest of the hill to
alleviate site distance problems. Staff stated the applicant was requesting a
variance to allow the terminus of a cul-de-sac nearer the property line than
typically allowed. Staff stated they were supportive of this variance request.
CI
FILE NO.: Z-7952 (Cont.
Staff noted comments from the various other reporting departments and
agencies; suggesting the applicant contact them individually for further
clarification. There was no further discussion of the item and the Committee then
forwarded the item to the full Commission for final action.
H. ANALYSIS:
The applicant submitted a revised site plan to staff addressing most of the issues
raised at the October 20, 2005, Subdivision Committee meeting. The applicant
has indicated a maximum building area for each of the lots. The applicant has
also indicated a ten foot restrictive access easement along the rear of the
proposed lots abutting Pinnacle Valley Road. The applicant has indicated a rear
yard platted building line as 25 -feet. The ordinance would typically require the
placement of a 35 -foot building line for lots abutting an arterial street
classification. Staff is supportive of the applicant's proposed building setback
adjacent to Pinnacle Valley Road.
The site includes the placement of 2.96 acres of green space, both public and
private. The ordinance typically requires a planned residential development to
set aside a minimum of 10 to 15 percent of the total development as common
open space. The ordinance also requires a minimum of 500 square feet per lot
of private open space. The applicant has indicated .59 acres of common open
space. The ordinance would typically require the placement of .69 acres of
common open space. The applicant has indicated each of the lots will have in
excess of 500 square feet of private open space. Staff is supportive of the
indicated open space both public and private.
The applicant is proposing the development of this site with 30 single-family
residential lots. The applicant has indicated 22 of the lots will be developed as
zero lot line single-family lots with the remaining 8 lots to be developed as typical
R-2, Single-family zoned lots. The applicant has proposed an average lot size of
7,663 square feet and a front building line of 15 -feet. Side yard setbacks are
typically eight feet for the zero lot line lots. The applicant has indicated Lots 2,
17, 25 — 30, the traditional single-family lots, will have an eight foot side yard
setback on each lot line. The ordinance typically requires a minimum lot width of
40 -feet and a minimum lot area of 4,000 square feet for zero lot line
developments. The applicant has proposed an average lot width of 48 -feet for
the proposed zero lot line lots. The applicant has also included the buildable
areas as required by the ordinance. The applicant has indicated a minimum lot
width at the front building line for each of the "traditional" single-family lots as
60 -feet.
The applicant has proposed the placement of a six foot fence within the required
building setback of Pinnacle Valley Road. The fencing is being proposed to allow
homeowners the option of placing a fence on the property line to add to privacy
and security. Staff is supportive of this request.
61
FILE NO.: Z-7952 (Cont.
The applicant has set aside an area for detention along the southern portion of
the site to comply with the City's storm water detention ordinance. The applicant
has also shown dedication of right-of-way (45 -feet from centerline) to meet the
current Master Street Plan standard. The applicant is requesting an in -lieu
contribution for the construction of Pinnacle Valley Road. Staff is supportive of
this request. The roadway will be constructed per Pulaski County standard for an
arterial street.
The applicant is requesting a variance to allow the development of the
subdivision with double frontage lots. The applicant has indicated Lots 2 — 14 as
double frontage lots. The applicant has also requested a variance to allow a
reduced building line adjacent to an arterial street. The ordinance typically
requires the placement of a 35 -foot building line adjacent to an arterial roadway.
The applicant has proposed the placement of a 20 -foot building line. The
applicant is also requesting a variance to allow the terminus of a cul-de-sac
street nearer the property line than typically allowed. The applicant has indicated
the terminus at 15 -feet from the property line. The ordinance typically requires
the terminus to be 75 -feet from the property line. Staff is supportive of the
applicant's requested variances. Staff does not feel the development with the
indicated variances will have a significant impact on the proposed subdivision or
the adjoining properties.
Staff is supportive of the applicant's request. The applicant is proposing the
development of the site as a single-family subdivision resulting in a density of
4.32 units per acre. To staff's knowledge there are no outstanding issues
associated with the proposed request. Staff feels the proposed development of
the proposed single-family subdivision should have minimal impact on the
adjoining properties.
STAFF RECOMMENDATION:
Staff recommends. approval of the request subject to compliance with the
conditions and comments outlined in paragraphs D, E, F and H of the above
agenda staff report.
Staff recommends approval of the applicant's requested variance to allow the
placement of a six foot fence within the required building setback along Pinnacle
Valley Road.
Staff recommends approval of the requested variance to allow the terminus of
the cul-de-sac street nearer the property line than typically allowed.
Staff recommends approval of the requested variance to allow Lots 2 — 14 to
develop as double frontage lots.
Staff recommends approval of the requested variance to allow Lots 2 — 14 to
develop with a reduced building line adjacent to an arterial roadway.
A
FILE NO.: Z-7952 (Cont.
PLANNING COMMISSION ACTION: (NOVEMBER 10, 2005)
The applicant was present representing the request. There were registered objectors
present. Staff presented the item with a recommendation of approval of the request
subject to compliance with the conditions and comments outlined in paragraphs D, E, F
and H of the agenda staff report. Staff also presented a recommendation of approval of
the applicant's requested variance to allow the placement of a six-foot fence within the
required building setback along Pinnacle Valley Road. Staff presented a
recommendation of approval of the applicant's requested variance to allow the terminus
of the cul-de-sac street nearer the property line than typically allowed, the requested
variance to allow Lots 2 — 14 to develop as double frontage lots and the requested
variance to allow Lots 2 — 14 to develop with a reduced building line adjacent to an
arterial roadway.
Mr. Wingfield Martin addressed the Commission in opposition of the proposed request.
He stated he felt the subdivision out of character with the neighborhood. He stated
Pinnacle Valley Road was a narrow road with 21 -feet of pavement and open ditches.
He stated there was a light at Pinnacle Valley Road and Highway 10, which the
neighborhood was grateful for, but the light was long and did not allow motorist from
Pinnacle Valley time for exiting. He stated traffic would back up on Pinnacle Valley
Road several cars deep before the light would change. He stated the addition of the
subdivision would create safety concerns for residents of the area and the new
homeowners.
Mr. Jimmy Greenfiled addressed the Commission in opposition of the proposed request.
He stated he felt the use of the property over powered the site. He stated with the
development there would be an additional 60 cars per day waiting in line for the light to
change at Pinnacle Valley Road and Highway 10. He stated he felt the development to
intense for the site and the site should be developed as the current development pattern
in the area.
Ms. Laura Mehaffy addressed the Commission in opposition of the proposed request.
She stated her opposition was to the traffic the proposed development would generate.
She stated her business was located next to the proposed development and at times it
was difficult to exit her driveway. She stated with the addition of the new homes in the
area this would only compound the problem.
There was a general discussion concerning the proposed development, the proposed
density and the development pattern in the area. Staff noted the density was within the
allowable density of single-family. Staff stated there was a mixture of residential types
located in the area. The discussion included the applicant's request for an in -lieu
contribution for construction of Pinnacle Valley Road. Staff stated they were supportive
of the in -lieu contribution. Staff stated they were not sure at what point the road would
be widened. Staff stated the roadway had been designed but there was not funding for
the construction. The Commission raised concerns with the road not being
constructed to serve the development.
7
ILE NO.: Z-7952 (Cont.
There was no further discussion of the item. The Chair entertained a motion for
approval of the item. The motion failed by a vote of 5 ayes, 4 noes and 2 absent.
1,
November 10, 2005
ITEM NO.: 20 FILE NO.: Z-7952
NAME: Pinnacle Valley Court Long -form PD -R
LOCATION: Located on Pinnacle Valley Road, just North of Cantrell Road
DEVELOPER:
St. Pat Properties, LLC
17 Portland Road
Little Rock, AR 72212
ENGINEER:
Central Arkansas Surveying
1012 Autumn Road
Little Rock, AR 72211
AREA: 6.93 acres NUMBER OF LOTS: 30 FT. NEW STREET: 973 LF
CURRENT ZONING: R-2, Single-family
ALLOWED USES: Single-family residential
PROPOSED ZONING: PD -R
PROPOSED USE: Single-family — Zero Lot Line Residential
VARIANCES/WAIVERS REQUESTED:
1. A variance, to allow the placement of a six-foot privacy fence within the required
building setback along Pinnacle Valley Road.
2. A variance to allow a reduced terminus (65 -feet and 75 -feet) of two cul-de-sac
streets from the property line.
3. A variance to allow the development of double frontage lots.
4. A variance to allow a reduced setback adjacent to Pinnacle Valley Road.
A. PROPOSAUREQUEST:
The applicant is proposing the development of this 6.93 -acre tract (303,177
square feet) with 30 single-family residential lots. The applicant has indicated 22
of the lots will be zero lot line single-family homes with the remaining 8 lots being
developed as typical R-2, Single-family zoned properties. The applicant has
indicated an average lot size of 7,663 square feet and the total green space
November 10, 2005
SUBDIVISION
ITEM NO.: 20 Cont. FILE NO.: Z-7952
provided is 129,213 square feet or 42 percent of the development. The applicant
has indicated the total proposed building footprint as 93,497 square feet. The
applicant has indicated a front building line of 15 -feet and a rear yard setback of
20 -feet along Pinnacle Valley Road. The applicant has indicated one side yard
setback of eight feet for the zero lot line lots to allow each lot outdoor living area.
The applicant has indicated Lots 2, 17, 25 — 30, the traditional single-family lots,
will have an eight foot side yard setback on each lot line.
The applicant is requesting a variance to allow the development of double
frontage lots for Lots 2 - 14. The applicant is also requesting a variance to allow
a reduced building line adjacent to an arterial street for Lots 2 -14.
The applicant has set aside an area for detention along the southern portion of
the site. The applicant has also indicated dedication of right-of-way (45 -feet from
centerline) to meet the current Master Street Plan standard.
B. EXISTING CONDITIONS:
The site is wooded with varying degrees of slope. Pinnacle Valley Road is a
narrow two lane roadway with open ditches for drainage. There is a veterinary
clinic located to the south of the site on property zoned PD -O. The primary use
in the area is single-family. There is a new single-family subdivision currently
being developed to the northwest of the site.
C. NEIGHBORHOOD COMMENTS:
As of this writing, staff has received several informational phone calls from area
residents. The Westchester Neighborhood Association and the River Valley
Neighborhood Association, all property owners located within 200 -feet of the site
and all residents who could be identified located within 300 feet of the site were
notified of the public hearing.
D. ENGINEERING COMMENTS:
Public Works Conditions:
1. Pinnacle Valley Road is classified on the Master Street Plan as a minor
arterial. A dedication of right-of-way 45 feet from centerline will be required.
2. With site development, provide design of street conforming to the Master
Street Plan. Construct one-half street improvement to Pinnacle Valley Road
including 5 -foot sidewalks with planned development.
3. Storm water detention ordinance applies to this property. Show the
proposed location for storm water detention facilities on the plan.
4. Prepare a letter of pending development addressing streetlights as required
by Section 31-403 of the Little Rock code. Contact Traffic Engineering at
2
November 10, 2005
SUBDIVISION
ITEM NO.: 20 Cont. FILE NO.: Z-7952
(501) 379-1813 (Steve Philpott) for more information regarding street light
requirements.
5. Obtain permits prior to doing any street cuts or curb cuts. Obtain barricade
permit prior to doing any work in the right-of-way. Contact Traffic Engineering
at (501) 379-1817 (Derrick Bergfield) for more. information.
6. On site striping and signage` plans should be forwarded to Public Works,
Traffic Engineering for approval with the site development package.
7. Proposed driveway location should be located at the crest of the hill to
alleviate site problems.
8. A grading permit in accordance with Section 29-186 (c) and (d) will be
required prior to any land clearing or grading activities at the site. Site
grading, and drainage plans will need to be submitted and approved prior to
the start of construction.
9. Obtain a NPDES storm water permit from the Arkansas Department of
Environmental Quality prior to the start of construction.
10. Street names and street naming conventions must be approved by Public
Works. Contact David Hathcock at (501) 371-4808.
11. Cul-de-sac should be designed with a right-of-way diameter of 100 ft and
pavement width diameter of 80 foot.
E. UTILITIES AND FIRE DEPARTMENT/COUNTY PLANNING:
Wastewater: Sewer main extension required, with easements, if service is
required for the project. Contact Little Rock Wastewater Utility at 688-1414 for
additional information.
Entergy: No comment received.
Center -Point Energy: No comment received.
SBC: No comment received.
Central Arkansas Water: All Central Arkansas Water requirements in effect at
the time of request for water service must be met. A Capital Investment Charge
based on the size of the meter connection(s) will apply to this project in addition
to normal charges. A water main extension will be required in order to provide
service to this property. This development will have minor impact on the existing
water distribution system. Proposed water facilities will be sized to provide
adequate pressure and fire protection.
Fire Department: Place fire hydrants per code. Contact the Little Rock Fire
Department at 918-3700 for additional information.
County Plannin : No comment.
3
November 10, 2005
SUBDIVISION
ITEM NO.: 20 Cont. FILE NO.: Z-7952
CATA: The site is not located on a dedicated CATA Bus Route.
F. ISSUES/TECHNICAL/DESIGN:
Planning Division: This request is located in the River Mountain Planning
District. The Land Use Plan shows Single Family with some Transition on the
southern portion. The applicant has applied for a Planned Development —
Residential for a residential development of 30 detached homes.
The request does not require a change to the Land Use Plan. The overall
density is less than what Single Family allows even though the development has
zero lot line homes in part of the development.
Master Street Plan: Pinnacle Valley .Road is shown as a Minor Arterial on the
Master Street Plan and may require dedication of right-of-way and may require
street improvements since it is built to a two-lane section at this time.
Bicycle Plan. The closest bikeway is a Class One which is on Taylor Loop
Road/Rahling Road and is located about one-quarter mile to the west of the site.
A Class One bikeway is totally separated from the automobile lanes.
City Recognized Neighborhood Action Plan: The applicant's property lies in the
area covered by the River Mountain Neighborhood Action Plan. The Residential
Development goal lists objectives of "Develop Neo -traditional neighborhoods
(pedestrian and bicycle friendly, which are less dependant on automobiles) in
areas that have not yet been developed" and an action statement of "Enforce the
construction of sidewalks with all types of developments.". Additional action
statements are to "Require street lighting be in place in new subdivisions at the
time streets are opened" and to "Require developers to install underground
utilities in all new subdivisions."
Landscape: No comment.
G. SUBDIVISION COMMITTEE COMMENT: (October 20, 2005)
The applicant was present representing the request. Staff presented an
overview of the proposed request indicating there were additional items
necessary to complete the review process. Staff stated a 10 -foot restrictive
access easement would be required along the rear of the lots abutting Pinnacle
Valley Road. Staff also stated the site plan included a building footprint and the
maximum buildable area. Staff requested the applicant provide the maximum
buildable area only.
Public Works comments were addressed. Staff stated with the site development
street improvements to Pinnacle Valley Road would be required. Staff also
4
November 10, 2005
SUBDIVISION
ITEM NO.: 20
FILE NO.: Z-7952
stated the proposed driveway location should be placed at the crest of the hill to
alleviate site distance problems. Staff stated the applicant was requesting a
variance to allow the terminus of a cul-de-sac nearer the property line than
typically allowed. Staff stated they were supportive of this variance request.
Staff noted comments from the various other reporting departments and
agencies; suggesting the applicant contact them individually for further
clarification. There was no further discussion of the item and the Committee then
forwarded the item to the full Commission for final action.
H. ANALYSIS:
The applicant submitted a revised site plan to staff addressing most of the issues
raised at the October 20, 2005, Subdivision Committee meeting. The applicant
has indicated a maximum building area for each of the lots. The applicant has
also indicated a ten foot restrictive access easement along the rear of the
proposed lots abutting Pinnacle Valley Road. The applicant has indicated a rear
yard platted building line as 25 -feet. The ordinance would typically require the
placement of a 35 -foot building line for lots abutting an arterial street
classification. Staff is supportive of the applicant's proposed building setback
adjacent to Pinnacle Valley Road.
The site includes the placement of 2.96 acres of green space, both public and
private. The ordinance typically requires a planned residential development to
set aside a minimum of 10 to 15 percent of the total development as common
open space. The ordinance also requires a minimum of 500 square feet per lot
of private open space. The applicant has indicated .59 acres of common open
space. The ordinance would typically require the placement of .69 acres of
common open space. The applicant has indicated each of the lots will have in
excess of 500, square feet of private open space. Staff is supportive of the
indicated open space both public and private.
The applicant is proposing the development of this site with 30 single-family
residential lots. The applicant has indicated 22 of the lots will be developed as
zero lot line single-family lots with the remaining 8 lots to be developed as typical
R-2, Single-family zoned lots. The applicant has proposed an average lot size of
7,663 square feet and a front building line of 15 -feet. Side yard setbacks are
typically eight feet for the zero lot line lots. The applicant has indicated Lots 2,
17, 25 — 30, the traditional single-family lots, will have an eight foot side yard
setback on each lot line. The ordinance typically requires a minimum lot width of
40 -feet and a minimum lot area of 4,000 square feet for zero lot line
developments. The applicant has proposed an average lot width of 48 -feet for
the proposed zero lot line lots. The applicant has also included the buildable
4N
November 10, 2005
SUBDIVISION
ITEM NO.: 20 Cont. FILE NO.: Z-7952
areas as required by the ordinance. The applicant has indicated a minimum lot
width at the front building line for each of the "traditional" single-family lots as
60 -feet.
The applicant has proposed the placement of a six foot fence within the required
building setback of Pinnacle Valley Road. The fencing is being proposed to allow
homeowners the option of placing a fence on the property line to add to privacy
and security. Staff is supportive of this request.
The applicant has set aside an area for detention along the southern portion of
the site to comply with the City's storm water detention ordinance. The applicant
has also shown dedication of right-of-way (45 -feet from centerline) to meet the
current Master Street Plan standard. The applicant is requesting an in -lieu
contribution for the construction of Pinnacle Valley Road. Staff is supportive of
this request. The roadway will be constructed per Pulaski County standard for an
arterial street.
The applicant is requesting a variance to allow the development of the
subdivision with double frontage lots. The applicant has indicated Lots 2 — 14 as
double frontage lots. The applicant has also requested a variance to allow a
reduced building line adjacent to an arterial street. The ordinance typically
requires the placement of a 35 -foot building line adjacent to an arterial roadway.
The applicant has proposed the placement of a 20 -foot building line. The
applicant is also requesting a variance to allow the terminus of a cul-de-sac
street nearer the property line than typically allowed. The applicant has indicated
the terminus at 15 -feet from the property line. The ordinance typically requires
the terminus to be 75 -feet from the property line. Staff is supportive of the
applicant's requested variances. Staff does not feel the development with the
indicated variances will have a significant impact on the proposed subdivision or
the adjoining properties.
Staff is supportive of the applicant's request. The applicant is proposing the
development of the site as a single-family subdivision resulting in a density of
4.32 units per acre. To staffs knowledge there are no outstanding issues
associated with the proposed request. Staff feels the proposed development of
the proposed single-family subdivision should have minimal impact on the
adjoining properties.
I. STAFF RECOMMENDATION:
Staff recommends approval of the request subject to compliance with the
conditions and comments outlined in paragraphs D, E, F and H of the above
agenda staff report.
A
November 10, 2005
SUBDIVISION
ITEM NO.: 20(Cont.)FILE NO.: Z-7952
Staff recommends approval of the applicant's requested variance to allow the
placement of a six foot fence within the required building setback along Pinnacle
Valley Road.
Staff recommends approval of the requested variance to allow the terminus of
the cul-de-sac street nearer the property line than typically allowed.
Staff recommends approval of the requested variance to allow Lots 2 — 14 to
develop as double frontage lots.
Staff recommends approval of the requested variance to allow Lots 2 — 14 to
develop with a reduced building line adjacent to an arterial roadway.
PLANNING COMMISSION ACTION:
(NOVEMBER 10, 2005)
The applicant was present representing the request. There were registered objectors
present. Staff presented the item with a recommendation of approval of the request
subject to compliance with the conditions and comments outlined in paragraphs D, E, F
and H of the agenda staff report. Staff also presented a recommendation of approval of
the applicant's requested variance to allow the placement of a six-foot fence within the
required building setback along Pinnacle Valley Road. Staff presented a
recommendation of approval of the applicant's requested variance to allow the terminus
of the cul-de-sac street nearer the property line than typically allowed, the requested
variance to allow Lots 2 — 14 to develop as double frontage lots and the requested
variance to allow Lots 2 — 14 to develop with a reduced building line adjacent to an
arterial roadway.
Mr. Wingfield Martin addressed the Commission in opposition of the proposed request.
He stated he felt the subdivision out of character with the neighborhood. He stated
Pinnacle Valley Road was a narrow road with 21 -feet of pavement and open ditches.
He stated there was a light at Pinnacle Valley Road and Highway 10, which the
neighborhood was grateful for, but the light was long and did not allow motorist from
Pinnacle Valley time for exiting. He stated traffic would back up on Pinnacle Valley
Road several cars deep before the light would change. He stated the addition of the
subdivision would create safety concerns for residents of the area and the new
homeowners.
Mr. Jimmy Greenfiled addressed the Commission in opposition of the proposed request.
He stated he felt the use of the property over powered the site. He stated with the
development there would be an additional 60 cars per day waiting in line for the light to
change at Pinnacle Valley Road and Highway 10. He stated he felt the development to
intense for the site and the site should be developed as the current development pattern
in the area.
7
ITEM NO.. 20. FILE NO.: Z-7952
� r . -U
NAME: Pinnacle Valley Court Long form PDR
LOCATION: located on Pinnacle Valley Road, just North of Cantrell Road
Planning Staff Comments:
1. Provide notification of property owne loc�A'zeV
within 200 -feet of the sit
complete with the certified abstract list, notice form with affidavit executed and
proof of mailing.
2. Provide a ten foot restricted access easement with a no right of vehicle access to
the lots abutting Pinnacle Valley Road.
3. The site plan indicates a maximum buildable area and a building footprint. Is the
intent to establish building setbacks or to provide a building footprint?
4. Proposed Lots 14 and 15 do not include a building setback along the common lot
line.
5. Provide a building setback lines.
6. Will the units have garages? Indicate the location of the anticipated drives.
Variance/Waivers:
1. A variance to allow the placement of a six-foot privacy fence within the required
building setback along Pinnacle Valley Road.
1A variance to allow a reduced terminus (65 -feet and 75 -feet) of two cul-de-sac
streets from the property line.
Public Works Conditions:
1, Pinnacle Valley Road is classified on the Master Street Plan as a minor arterial.
A dedication of right-of-way 45 feet from centerline will be required.
2. With site development, provide design of street conforming to the Master Street
Plan. Construct one-half street improvement to Pinnacle Valley Road including
5 -foot sidewalks with planned development.
3. Storm water detention ordinance applies to this property. Show the proposed
location for storm water detention facilities on the plan.
4. Prepare a letter of pending development addressing streetlights as required by
Section 31-403 of the Little Rock code. Contact Traffic Engineering at (501) 379-
1813 (Steve Philpott) for more information regarding street light requirements.
5. Obtain permits prior to doing any street cuts or curb cuts. Obtain barricade
permit prior to doing any work in the right-of-way. Contact Traffic Engineering at
(501) 379-1817 (Derrick Bergfield) for more information.
6. On site striping and signage plans should be forwarded to Public Works, Traffic
Engineering for approval with the site development package.
7. Proposed driveway location should be located at the crest of the hill to alleviate
site problems.
J L
8. A grading permit in accordance with Section 29-186 (c) and (d) will be required
prior to any land clearing or grading activities at the site. Site grading, and
drainage plans will need to be submitted and approved prior to the start of
construction.
9. Obtain a NPDES storm water permit from the Arkansas Department of
Environmental Quality prior to the start of construction.
10. Street names and street naming conventions must be approved by Public
Works. Contact David Hathcock at (501) 371-4808.
11. Cul-de-sac should be designed with a right-of-way diameter of 100 ft and
pavement width diameter of 80 foot.
Utilities and Fire Department/County Planning:
Wastewater: Sewer main extension required, with easements, if service is required
for the project. Contact Little Rock Wastewater Utility at 688-1414 for additional
information.
Entergy
Center -Point Energy:
SBC:
Central Arkansas Water: All Central Arkansas Water requirements in effect at the
time of request for water service must be met. A Capital Investment Charge based
on the size of the meter connection(s) will apply to this project in addition to normal
charges. A water main extension will be required in order to provide service to this
property. This development will have minor impact on the existing water distribution
system. Proposed water facilities will be sized to provide adequate pressure and fire
protection.
Fire Department: Place fire hydrants per code. Contact the Little Rock Fire
Department at 918-3700 for additional information.
County Planning: No comment.
CATA: The site is not located on a dedicated CATA Bus Route.
Planning Division:
Landscape: No comment.
Revised plattplan: Submit four (4) copies of a revised preliminary plan (to
include the additional information as noted above) to staff on Wednesday, October
26, 2005.