HomeMy WebLinkAboutZ-7950-A Staff AnalysisFILE NO.: Z -7950-A
NAME: ARM Revised Short -form PD -O
LOCATION: Located at 4016 Stannus Road
DEVELOPER:
Mark L. Pollack
Pollack Realty LLC
4016 Stannus Road
P.O. Box 22717
Little Rock, AR 72221
FNC,'INFFR-
Riddle Engineering
4600 West Markham
Little Rock, AR 72205
AREA: 0.981 acres
CURRENT ZONING:
NUMBER OF LOTS: 1
ALLOWED USES: General and Professional Office
FT. NEW STREET: 0 LF
PROPOSED ZONING: PD -O
PROPOSED USE: General and Professional Office — Allow building addition and
additional parking
VARIANCEMAIVERS: None requested.
BACKGROUND:
Ordinance No. 19,473 adopted by the Little Rock Board of Directors on February 7,
2006, rezoned the site from R-3, Single-family to PD -O to allow an existing structure to
be utilized as an office use. Interior renovations were proposed to the structure and the
existing parking lot was to be resurfaced. The applicant proposed a six (6) foot fence
along the street right-of-way of West 41St Street and Stannus Road. A gate was to be
placed along Stannus Road. Fencing was also proposed to be placed along the
mid -point of the property with the remainder of the parking to be left open for employees
of Wilson Elementary School and Rosedale Baptist Church to utilize as overflow
.: Z -7950-A (Cont.
parking. The structure contained 5,600 square feet and was constructed as a Masonic
Lodge in 1951. Prior to the applicant's occupancy the structure had been vacant
since 1998.
The site plan included a Phase II portion for development. The applicant indicated
future plans included the construction of a second building on the site not to exceed
5,600 square feet. All required parking to satisfy an office development would be
included in the redevelopment of the Phase II portion of the site.
A. PROPOSAL/REQUEST/APPLICANT'S STATEMENT:
Affirmative Risk Management continues to grow and as a result is approaching
the Planning and Development Department in order to obtain permission to add
to the existing building and also encompass the remainder of ARM's existing
parking lot within the fenced compound. At the present time the existing parking
lot at the rear of ARM's current structure is not enclosed with fencing and is being
utilized as a basketball area (ARM funded this and paved the area for local
children to play for the last 6 -years) and for overflow parking for PTA meetings
and school events related to Wilson Elementary.
As ARM has grown it has taken over existing training, conference, and storage
areas within its current structure to seat personnel. As a result, ARM is in need
of new floor space to utilize as on site storage of documents, supplies and
equipment. ARM is currently using floor space from Rosedale Baptist Church for
this purpose as an overflow. This agreement with Rosedale will likely not be
available in the future.
In addition, ARM's training area and conference room(s) are no longer available
for their intended purpose which creates a hardship related to continuing
education of staff and business meetings along with a location for staff to enjoy
their lunches.
Based on historical activities of ARM there is not any anticipated increase in the
traffic associated with an expansion of the existing structure or encompassing the
existing parking lot. If approved the rear parking lot will be used to replace
parking spaces that will be lost as a result of the building expansion.
B. EXISTING CONDITIONS:
The site is located across from Wilson Elementary School and adjacent to
Rosedale Baptist Church. Currently the parking lot is being utilized as overflow
parking for Wilson Elementary School and Rosedale Baptist Church. The site
contains a two story structure currently being used as an office. There is a
narrow drive, which extends from Stannus Road to the rear parking area on both
the north and south sides of the building. There is very little landscaping or
green space located on the site.
16
FILE NO.: Z -7950-A (Cont.
Wilson Elementary School is located to the east of the site and Rosedale Baptist
Church is located to the southwest of the site. There are single-family homes
located to the south, across West 41St Street, and to the north, fronting 40th
Street.
C. NEIGHBORHOOD COMMENTS:
As of this writing, staff has received one informational phone call from the John
Barrow Neighborhood Association. All property owners located within 200 -feet of
the site along with the John Barrow Neighborhood Association were notified of
the public hearing.
D. ENGINEERING COMMENTS:
PUBLIC WORKS CONDITIONS:
1. Due to the proposed use of the property, the Master Street Plan specifies that
Stannus Street for the frontage of this property must meet commercial street
standards. Dedicate right-of-way to 25 feet from centerline. - Ordinance
#19,474
2. Due to the proposed use of the property, the Master Street Plan specifies that
41St Street for the frontage of this property must meet commercial street
standards. Dedicate right-of-way to 25 feet from centerline. Provide a survey
showing the centerline of 41 st Street. - Ordinance #19,474
3. A 20 foot radial dedication of right-of-way is required at the intersection of
Stannus Street and 41St Street.
4. With site development, provide the design of street conforming to the Master
Street Plan. Construct one-half street improvement to Stannus Street and
41St Street including 5 -foot sidewalks with the planned development.
Ordinance #19,474 was approved in 2006 for deferral of all boundary street
improvements for 5 -years. The street improvements have not been
constructed as required by ordinance. The new back of curb should be
located 15.5 feet from centerline on Stannus Street and 41St Street. At least a
width of 20 feet of total pavement must be provided.
5. The existing fence along Stannus Street is located within the public right-of-
way and is not permitted. Obtain a franchise agreement from Public Works
(Bennie Nicolo, 371-4818) for the private improvements located in the right-
of-way.
6. A backup area is not provided for parking spaces 33 & 34.
7. The parking lot stormwater flume should not drain over the future sidewalk
along 41St Street.
3
NO.: Z -7950-A (Cont.
E. UTILITIES AND FIRE DEPARTMENT/COUNTY PLANNING:
Wastewater: Existing sewer main on site. No construction of any new buildings
within five feet of existing sewer main. Contact Little Rock Wastewater for
details.
Entergy: Entergy has no objection. Building expansion appears to be clear of
existing power lines.
Center -Point Ener : No comment received.
AT & T: No comment received.
Central Arkansas Water:
1. All Central Arkansas Water requirements in effect at the time of request for
water service must be met.
2. Contact Central Arkansas Water if additional fire protection or metered water
service is required.
3. Contact Central Arkansas Water regarding the size and location of the water
meter.
4. A Capital Investment Charge based on the size of meter connection(s) will
apply to this project in addition to normal charges. This fee will apply to all
connections including metered connections off the private fire system.
5. Due to the nature of this facility, installation of an approved reduced pressure
zone backflow preventer assembly (RPZ) is required on the domestic water
service. This assembly must be installed prior to the first point of use.
Central Arkansas Water requires that upon installation of the RPZA,
successful tests of the assembly must be completed by a certified Assembly
Tester licensed by the State of Arkansas and approved by Central Arkansas
Water. The test results must be sent to Central Arkansas Water's Cross
Connection Section within ten days of installation and annually thereafter.
Contact the Cross Connection Section at 377-1226 if you would like to
discuss backflow prevention requirements for this project.
Fire Department: Place fire hydrant(s) per code. Maintain access. Contact the
Little Rock Fire Department for additional information.
County Planning: No comment.
CATA: Less than % mile for both Routes #9 and #14.
Parks and Recreation: No comment received.
M
FILE NO.: Z -7950-A (Cont.
F. ISSUES/TECHNICAL/DESIGN:
Planning Division: This request is located in the John Barrow Planning District.
The Land Use Plan shows Public Institutional (PI) for this property. This category
includes public and quasi -public facilities that provide a variety of services to the
community such as schools, libraries, fire stations, churches, utility substations,
and hospitals. The applicant has applied for a revision of an existing PD -O
(Planned Office District) to allow for a building expansion and additional parking.
Master Street Plan: Stannus Road is shown as a Local Street on the Master
Street Plan. The primary function of a Local Street is to provide access to
adjacent properties. Local Streets that are abutted by non-residential zoning/use
or more intensive zoning than duplexes are considered as "Commercial Streets".
This street may require dedication of right-of-way and may require street
improvements for entrances and exits to the site.
Bicycle Plan: There are no bike routes shown in the immediate vicinity.
Landscape:
1. Site plan must comply with the City's landscape and buffer ordinance
requirements.
2. The property to the west is zoned R-3, Single-family therefore, a seventeen
foot (17') land use buffer is required.
3. As a component of all land use buffer requirements, opaque screening,
whether a fence or other device, a minimum of six (6) feet in height shall be
required upon the property line side of the buffer. The plantings, existing and
purposed, shall be provided within the landscape ordinance of the City,
Section 15-81.
4. All vehicular use areas which were not in compliance with the City's
landscape ordinance may continue as non -conforming until such time a
building permit is issued to rehabilitate a structure on the property exceeding
(50) percent of current replacement cost of the structure. At such time (50)
percent of the existing vehicular use area shall be brought into compliance
and shall continue to full compliance on a graduated scale based on the
percentage of rehabilitation cost.
5. Interior landscape areas shall comprise a minimum of eight (8) percent of any
vehicular use area containing twelve (12) or more parking spaces.
6. The City Beautiful Commission recommends preserving as many existing
trees as feasible on this site. Credit toward fulfilling Landscape Ordinance
requirements can be given when preserving trees of six (6) inch caliper or
larger.
5
FILE NO.: Z -7950-A
G. SUBDIVISION COMMITTEE COMMENT-. (December 5, 2013)
Mr. Mark L. Pollack of ARM was present representing the request. Staff
presented an overview of the development stating there were a few outstanding
technical issues associated with the request in need of addressing. Staff
requested the site plan clearly identify the property lines. Staff also requested
details of the proposed fencing to be located within the rear of the property
including construction materials and total height.
Public Works comments were addressed. Staff stated right of way dedication
was required to 50 -feet from centerline on Stannus Road and West 41St Street.
Staff stated with the approval in 2006 a 5 -year deferral was approved for the
street construction to the abutting streets. Staff stated the deferral time had
expired and the improvements were now required. Staff stated any private
improvements located in the right of way would require a franchise agreement.
Staff stated the parking lot flume should not drain onto the future sidewalk along
West 41 st Street.
Landscaping comments were addressed. Staff stated the property to the west
was zoned residentially therefore a 17 -foot land use buffer was required. Staff
stated screening was also required along this perimeter as well. Staff stated
interior landscape areas were to comprise a minimum of eight percent of any
vehicular use area which contained twelve or more parking spaces.
Staff noted comments from the other reporting departments and agencies
suggesting the applicant contact them individually for additional clarification.
There was no further discussion of the item. The Committee then forwarded the
item to the full Commission for final action.
H. ANALYSIS:
The applicant submitted a revised site plan addressing staff's concerns raised at
the December 5, 2013, Subdivision Committee meeting. The revised plan clearly
identifies the property lines, indicates the proposed fencing to be located around
the perimeters, and the minimum landscape strips required by the buffer and
landscape ordinances.
The request is to amend the previously approved PD -O to allow the existing
office user to expand their present building square footage. The existing building
contains 5,608 square feet located on two levels. The proposed addition is to
allow 4,128 square feet of floor area on two levels. Upon completion the total
building square footage on both levels will be 9,736 square feet of floor area.
The site plan indicates the placement of 34 on-site parking spaces. Four of the
spaces will be located in front of the building and the remaining spaces will
be located in the rear of the building. Based on the typical minimum parking
D
FILE NO.: Z -7950-A (Cont.
required to serve an office use 24 parking spaces would typically be required.
Currently the proposed parking area in the rear of the building is paved but not
striped for parking. Upon redevelopment of the site striping and landscape
islands will be installed in this area.
The site plan indicates perimeter fencing will be placed along the western
property line and the southern property where not currently in place. The plan
indicates plant materials will be placed along the western and northern perimeter
to provide screening of the adjacent property.
The typical hours of operation are from 8:00 am to 5:00 pm Monday through
Friday. The applicant has indicated based on their business and the clients they
serve, many in different time zones and some overseas, there are employees
who work outside these hours. The employees are allowed flextime hours to
allow mothers to be home with their children when they arrive home from school.
The applicant is requesting the hours of operation be amended to 6:00 am to
7:00 pm but be allowed the flexibility to allow employees to work additional hours
when necessary to meet client's needs.
The applicant has provided the right of way dedication and sidewalk to meet the
Boundary Street and Master Street Plan requirement. The applicant was
previously allowed a 5 -year deferral of the required improvements to Stannus
and 41St Streets. The deferral has expired and the street construction must be
completed with the current application request.
The landscaping proposed with the new parking area is not in full compliance
with the typical standards of the Landscape Ordinance. Staff feels with additional
plantings the landscaping as proposed meets the intent of the ordinance. Staff
recommends in addition to the existing trees and shrubs shown on the site plan
the applicant provide one (1) additional tree and place additional shrubs within
the landscape area on Stannus Road to screen the paved area. In addition staff
recommends additional shrubs be placed within the landscape strip along 41St
Street adjacent to the paved area to aid in screening the parking lot.
Staff is supportive of the request. To staff's knowledge there are no remaining
outstanding technical issues associated with the request. Staff does not feel the
building expansion as proposed will adversely impact the development or the
area.
STAFF RECOMMENDATION:
Staff recommends approval of the request subject to compliance with the
comments and conditions as outlined in paragraphs D, E and F of the agenda
staff report.
7
FILE NO.: Z -7950 -A -(Cont.)
Staff recommends one additional tree and additional shrubs be placed along
Stannus Road and additional shrubs be placed adjacent to the paved area along
41St Street to screen the parking areas.
PLANNING COMMISSION ACTION: (JANUARY 9, 2014)
The applicant was not present. There were no registered objectors present.
Staff presented the item stating the applicant had submitted a request dated
December 10, 2013., requesting deferral of the item to the February 20, 2014, public
hearing. Staff stated they were supportive of the deferral request.
There was no further discussion of the item. The Chair entertained a motion for
approval of the item as presented by staff. The motion carried by a vote of 6 ayes,
0 noes, 4 absent and 1 open position.
PLANNING COMMISSION ACTION: (FEBRUARY 20, 2014)
The applicant was present. There were no registered objectors present. Staff
presented the item with a recommendation of approval of the request subject to
compliance with the comments and conditions as outlined in paragraphs D, E and F of
the agenda staff report. Staff presented a recommendation one additional tree and
additional shrubs be placed along Stannus Road and additional shrubs be placed
adjacent to the paved area along 41St Street to screen the parking areas.
There was no further discussion of the item. The Chair entertained a motion of approval
of the item as presented by staff. The motion carried by a vote of 10 ayes 0 noes and
1 absent.
E-3
ITEM NO-- 13. Z -7950-A
NAME: ARM Revised Short -form PD -O
LOCATION: located at 4016 Stannus Road
Planning Staff Comments:
1. Provide notification of the abutting property owners including the certified abstract
list, notice form with affidavit executed and proof of mailing. The notice must be
mailed no later than December 25, 2013. The Office of Planning and Development
must receive the proof of notice no later than January 3, 2014.
2. The previous approval limited the hours to 8 to 5 and 25 to 30 employees. Are the
hours and number of employees still consistent with the use of the property?
3. Provide details of the proposed fencing to be located within the rear of the property.
Provide the construction material, total height and location.
4. Provide a site plan indicating the parking both existing and proposed. The detail
should include any proposed landscaping and landscape islands.
5. Clearly identify the property lines on the proposed site plan.
Variance/Waivers. None requested.
Public Works Conditions:
1. Due to the proposed use of the property, the Master Street Plan specifies that
Stannus Street for the frontage of this property must meet commercial street
standards. Dedicate right-of-way to 25 feet from centerline. -Ordinance #19,474
2. Due to the proposed use of the property, the Master Street Plan specifies that 41St
Street for the frontage of this property must meet commercial street standards.
Dedicate right-of-way to 25 feet from centerline. Provide a survey showing the
centerline of 41St Street. - Ordinance #19,474
3. A 20 foot radial dedication of right-of-way is required at the intersection of Stannus
Street and 41St Street.
4. With site development, provide the design of street conforming to the Master Street
Plan. Construct one-half street improvement to Stannus Street and 41St Street
including 5 -foot sidewalks with the planned development. Ordinance #19,474 was
approved in 2006 for deferral of all boundary street improvements for 5 -years. The
street improvements have not been constructed as required by ordinance. The new
back of curb should be located 15.5 feet from centerline on Stannus Street and 41St
Street. At least a width of 20 feet of total pavement must be provided.
5. The existing fence along Stannus Street is located within the public right-of-way and
is not permitted. Obtain a franchise agreement from Public Works (Bennie Nicolo,
Item # 13.
371-4818) for the private improvements located in the right-of-way.
6. A backup area is not provided for parking spaces 33 & 34.
7. The parking lot stormwater flume should not drain over the future sidewalk along 41St
Street.
Utilities and Fire Department/County Planning:
Wastewater: Existing sewer main on site. No construction of any new buildings within
five feet of existing sewer main. Contact Little Rock Wastewater for details.
Entergy: No comment received.
Center -Point Energy: No comment received.
AT & T: No comment received.
Central Arkansas Water:
1. All Central Arkansas Water requirements in effect at the time of request for water
service must be met.
2. Contact Central Arkansas Water if additional fire protection or metered water service
is required.
3. Contact Central Arkansas Water regarding the size and location of the water meter.
4. A Capital Investment Charge based on the size of meter connection(s) will apply to
this project in addition to normal charges. This fee will apply to all connections
including metered connections off the private fire system.
5. Due to the nature of this facility, installation of an approved reduced pressure zone
backflow preventer assembly (RPZ) is required on the domestic water service. This
assembly must be installed prior to the first point of use. Central Arkansas Water
requires that upon installation of the RPZA, successful tests of the assembly must
be completed by a certified Assembly Tester licensed by the State of Arkansas and
approved by Central Arkansas Water. The test results must be sent to Central
Arkansas Water's Cross Connection Section within ten days of installation and
annually thereafter. Contact the Cross Connection Section at 377-1226 if you would
like to discuss backflow prevention requirements for this project.
Fire Department: Place fire hydrant(s) per code. Maintain access. Contact the Little
Rock Fire Department for additional information.
County Planning: No comment.
CATA: Less than '/4 mile for both Routes #9 and #14.
Item # 13.
Parks and Recreation: No comment received.
Planning Division: This request is located in the John Barrow Planning District. The
Land Use Plan shows Public Institutional (PI) for this property. This category includes
public and quasi -public facilities that provide a variety of services to the community such
as schools, libraries, fire stations, churches, utility substations, and hospitals. The
applicant has applied for a revision of an existing PD -O (Planned Office District) to allow
for a building expansion and additional parking.
Master Street Plan: Stannus Road is shown as a Local Street on the Master Street
Plan. The primary function of a Local Street is to provide access to adjacent properties.
Local Streets that are abutted by non-residential zoning/use or more intensive zoning
than duplexes are considered as "Commercial Streets". This street may require
dedication of right-of-way and may require street improvements for entrances and exits
to the site.
Bicycle Plan: There are no bike routes shown in the immediate vicinity.
Landscape:
1. Site plan must comply with the City's minimal landscape and buffer ordinance
requirements.
2. The property to the west is zoned R-3, Single-family therefore, a seventeen foot (17')
land use buffer is required.
3. As a component of all land use buffer requirements, opaque screening, whether a
fence or other device, a minimum of six (6) feet in height shall be required upon the
property line side of the buffer. The plantings, existing and purposed, shall be
provided within the landscape ordinance of the City, Section 15-81.
4. All vehicular use areas which were not in compliance with the City's landscape
ordinance may continue as non -conforming until such time a building permit is
issued to rehabilitate a structure on the property exceeding (50) percent of current
replacement cost of the structure. At such time (50) percent of the existing vehicular
use area shall be brought into compliance and shall continue to full compliance on a
graduated scale based on the percentage of rehabilitation cost.
5. Interior landscape areas shall comprise a minimum of eight (8) percent of any
vehicular use area containing twelve (12) or more parking spaces.
6. The City Beautiful Commission recommends preserving as many existing trees as
feasible on this site. Credit toward fulfilling Landscape Ordinance requirements can
be given when preserving trees of six (6) inch caliper or larger.
Revised plat/plan: Submit four (4) copies of a revised preliminary plat/plan (to include
the additional information as noted above) to staff on Wednesday, December 11, 2013.
Item 4 11