Loading...
HomeMy WebLinkAboutZ-7854-D Map 1EXISTING PARKING TO BE REMOVED PROPOSED 6' WOOD PRIVACY FENCE IN E EXISTING SCREENED DUMPSTER TO REMAIN 4 GENERAL NOTES 2. 17' PROPOSED BUILDING ADDITION 5,212 SF m r; u 15 ]--EXISTING 6' WOOD PRIVACY FENCE TO BE EXISTING ASPHALT REMOVED PARKING ,®_�, T Ifl ------ 11 iii u EXISTING PARKING I EXISTING ASPHALT TO BE REMOVED I DRIVE 1. ENGINEER'S NOTICE TO CONTRACTOR: THE EXISTENCE AND LOCATION OF ANY UNDERGROUND UTILITY PIPES OR STRUCTURES SHOWN ON THESE DRAWINGS ARE OBTAINED BY A SEARCH OF THE AVAILABLE ?---CORDS. TO THE BEST OF OUR KNOWLEDGE THERE ARE NO EXISTING UTILITIES EXCEPT AS SHOWN ON THESE DRAWINGS AND WE ASSUME NO RESPONSIBILITY AS TO THE ACCURACY OF THEIR DEPICTED LOCATION ON THESE DRAWINGS. THE CONTRACTOR IS REQUIRED TO TAKE DUE PRECAUTIONARY MEASURES TO PROTECT THE UTILITY LINES SHOWN, AND ALL OTHER LINES NOT OF RECORD OR NOT SHOWN ON THESE DRAWINGS BY VERIFICATION OF THEIR LOCATION IN THE FIELD PRIOR TO THE INITIATION OF THE ACTUAL PORTION OF THEIR WORK. 2. SAFETY NOTICE TO CONTRACTOR: IN ACCORDAIICE WITH GENERALLY ACCEPTED CONSTRUCTION PRACTICES, THE CONTRACTOR WILL BE SOLELY AND COMPLETELY RESPONSIBLE FOR CONDITIONS OF THE JOB SITE, INCLUDING SAFETY OF ALL PERSONS AND PROPERTY DURING PERFORMANCE OF THE WORK. THIS REQUIREMENT WILL APPLY CONTINUOUSLY AND NOT BE LIMITED TO NORMAL WORKING HOURS. THE DUTY OF THE ENGINEER TO CONDUCT CONSTRUCTION REVIEW OF THE CONTRACTOR'S PERFORMANCE IS NOT INTENDED TO INCLUDE REVIEW OF THE ADEQUACY OF THE CONTRACTOR'S SAFETY MEASURES, IN, OR NEAR THE CONSTRUCTION SITE. 3, OWNERSHIP OF DOCUMENTS: THIS DOCUMENT, AND THE IDEAS AND DESIGNS INCORPORATED HEREIN, AS AN INSTRUMENT OF PROFESSIONAL SERVICES, IS THE PROPERTY OF CRAFTON, TULL & ASSOCIATES, INC., AND IS NOT TO BE USED, IN WHOLE OR PART, FOR ANY OTHER PROJECT WITHOUT THE WRITTEN AUTHORIZATION OF CRAFTON, TULL & ASSOCIATES, INC. 4. CONTRACTOR SHALL NOT CAUSE ANY INCONVENIENCE TO THE PUBLIC, ADJACENT PROPERTY OWNERS, PEDESTRIANS, ETC. DURING THE CONSTRUCTION OF THIS PROJECT. THE CONTRACTOR SHALL NOT DISRUPT ACCESS TO ADJACENT PROPERTIES AT ANY TIME DURING CONSTRUCTION. 5. THE CONTRACTOR SHALL CONTACT THE ENGINEER FOR CLARIFICATION IF A DISCREPANCY OR INCONSISTENCY IS IDENTIFIED ON THE PLANS AND/OR SPECIFICATIONS. 6. CONTRACTOR IS RESPONSIBLE FOR THE DESIGN AND IMPLEMENTATION OF ALL REQUIRED/NECESSARY SHEETING, SHORING, AND SPECIAL EXCAVATION MEASURES REQUIRED ON THE PROJECT TO MEET OSHA, FEDERAL, STATE AND EXISTING ONE STORY BUILDING (10,990 SF) PROPOSED PLAYGROUND EXPANSION 1,062 SF tf'� SITE NOTES EXISTING ASP --- PARKING PROPOSED 6' WOOD PRIVACY FENCE 1. ALL WORK AND MATERIALS SHALL COMPLY WITH ALL CITY/COUNTY/STATE/FEDERAL REGULATIONS AND CODES AND OSHA STANDARDS. 2. CONTRACTOR SHALL REFER TO ARCHITECTURAL PLANS FOR EXACT LOCATIONS AND "MENSIONS OF VESTIBULES, SLOPE PAVING, SIDEWALKS, EXIT PORCHES, TRUCK DOCKS, PRECISE BUILDING DIMENSIONS AND EXACT UTILITY ENTRANCE LOCATIONS. 3. ALL DIMENSIONS AND RADII ARE TO BACK OF CURB UNLESS OTHER'.VISE NOTED. 4. ALL WORK SHALL BE DONE IN STRICT ACCORDANCE WITH THE PROJECT SPECIFICATIONS, 5. ALL CURB/SIDEWALK/HANDICAP RAMP DESIGNS SHALL CONFORM TO ADA STANDARDS OR LOCAL RESTRICTIVE CODES, WHICHEVER IS MORE RESTRICTIVE. 6. CONTRACTOR SHALL ENSURE ALL NECESSARY PERMITS ARE OBTAINED PRIOR TO CONSTRUCTION START. 7. CONTRACTOR SHALL MATCH PROPOSED CURB AND GUTTER, CONCRETE, AND PAVEMENT TO EXISTING IN GRADE AND ALIGNMENT. 8. CONTRACTOR SHALL MAINTAIN ALL EXISTING PARKING, SIDEWALKS, DRIVES, ETC. CLEAR AND FREE FROM ANY CONSTRUCTION ACTIVITY AND/OR MATERIAL TO ENSURE EASY AND SAFE PEDESTRIAN AND VEHICULAR TRAFFIC TO AND FROM THE SITE. STANDARD PARKING SPACES HANDICAP PARKING SPACES 46 4 TOTAL PARKING SPACES 50 CURB INLET TOP 320.74 FL BOX 315.02 TARYfSEWER MH TOP IM 319.82 FL 8 N. 314.08 CURB INLET TOP 316,96 FL BOX 311.84 CURB INLET TOP 320.52 FL BOX 314.27 CURB INLET TOP 316.69 FL BOX 311.04 Coe UTILITY COMPANIES WATER TELEPHONE CENTRAL ARKANSAS WATER AT&T/SBC 221 EAST CAPITAL AVENUE 1111 W. CAPITAL AVE. LITTLE ROCK, AR 72202 LITTLE ROCK, AR 72203 (501) 377-1225 (501) 373-6594 WASTEWATER NATURAL GAS LITTLE ROCK WASTEWATER UTILITY CENTERPOINT ENERGY 11 CLEARWATER DRIVE 2205 EAST ROOSEVELT ROAD LITTLE ROCK, AR 72204 LITTLE ROCK, AR 72201 (501) 688-1414 (501) 377-4558 ELECTRIC ENTERGY 425 W. CAPITAL AVE. LITTLE ROCK, AR 72201 (501) 377-5614 DRAINAGE & ROADWAY CITY OF LITTLE ROCK 701 W. MARKHAM ST. LITTLE ROCK, AR. 72203 PHONE: (501) 371-4831 CENTERPOINT ENERGY 2205 EAST ROOSEVELT ROAD LITTLE ROCK, AR 72201 PHONE: (501) 377-4558 CABLE TELEVISION COMCAST CABLE 1020 W. 4TH STREET LITTLE ROCK, AR 72201 (501) 375-5755 TRAFFIC AND ACCESS CITY OF LITTLE ROCK 621 SOUTH BROADWAY LITTLE ROCK, AR. 72201 PHONE: (501) 329-1800 *3 GRAPHIC SCALE IN FEET 30' 0 30' Col. PROPERTY DESCRIPTION LOT 5 EPA TALLEY ROAD ADDITION TO THE CITY OF LITTLE ROCK, PULASKI COUNTY, ARKANSAS C40)PROJECT INFORMATION SYMBOLS FOUND IRON PIN BALDING SETBACK: FRONT 70' 'Q POWER POLE SIDE 30' TELEPHONE PEDESTAL UNDERGROUND TELEVISION REAR 12' REQUESTED SITE AREA: 1.38 AC. SANITARY SEWER CLEANOUT BUILDING SIZE: 10,990 SQ. FT. EXISTING PHASE 1 GAS VALVE 16,202 SQ. FT. TOTAL FOLLOWING PHASE 2 BUILDING USAGE: CHILDCARE AND REHAB ZUNING: P.I.D WITH I-1 USES ALLOWED C8 INCLUDING CHILD CARE AND REHAB. PROPERTY USAGE: CHILDCARE AND REHAB BUILDING HEIGHT: < 35'-0°' O LEGEND (EXISTING) o SYMBOLS FOUND IRON PIN -4 LIGHT POLE 'Q POWER POLE m TELEPHONE PEDESTAL UNDERGROUND TELEVISION TV PEDESTAL O MANHOLE o SANITARY SEWER CLEANOUT o GAS METER Da GAS VALVE 1206 STORM SEWER PIPE .. ...... . ...... __... BARBED WIRE FENCE DOWN GUY D14 WATER VALVE �Y FIRE HYDRANT ASSEMBLY C8 AIR RELEASE VALVE TREE TO BE REMOVED FIRE DEPARTMENT CONNECTION LINEWORK -------------- EASEMENT ----------------------------- CURB INTERMEDIATE CONTOUR INDEX CONTOUR SANITARY SEWER LINE GAS LINE ----n WATER LINE (SPECIFY SIZE & TYPE) ---ucT UNDERGROUND TELEPHONE —UGE— 1 UNDERGROUND ELECTRIC 0 WATER METER OVERHEAD ELECTRIC ® SPRINKLER HEAD ----Wry E ELECTRIC PEDESTAL UNDERGROUND TELEVISION CURB GRATED INLET OVERHEAD TELEVISION 1206 DROP INLET CHAIN LINK FENCE INTERMEDIATE CONTOUR Q WOOD FENCE 1206 TREE..... .. ...... . ...... __... BARBED WIRE FENCE INDEX CONTOUR o SANITARY SEWER UANOUT • FIBER OPTIC e: SANITARY SEWER LINE TREE TO BE REMOVED GAS VALVE RIGHT OF WAY LEGEND (PROPOSED) LINEWCRK • BUILDING SET BACK RIGHT OF WAY PROPERTY LINE ROAD CENTERLINE SITE ENGINEER: CRAFTON, TULL, SPARKS & ASSOCIATES, INC. 10825 FINANCIAL CENTER PARKWAY, SUITE 300 LITTLE ROCK, AR 72211 PHONE: 501.664.3245 FAX: 501.664.6704 SITE DEVELOPER: DAVID PREWETT BWWP VENTURES, LLC 220 NORTH KNOXVILLE RUSSELLVILLE, AR 72801 FES 2 2015 (479) 890-5232 PHONE (479) 880-6057 CELL REQUIRED PARKING: 41 (1 SPACE/400 SF) PROVIDED PARKING: 50 SPACES 10825 Financial Center Parkway, Suite 300 Little Rock, Arkansas 72211 00 Crafton Tull engineering I surveying 501.664.3245t 501.664.6704f www.craftontull.com CERTIFICATE OF AUTHORIZATION: ,nO'F AU�p CRAFTON, TULL & ASSOCIATES, INC. z o< No. 109 J ?C, q�'rgN5A5 EPK;IWE�R LOT 5 EPA TALLEY ROAD ADDITION 5 REMINGTON COVE LITTLE ROCK, ARKANSAS i8 I Key Plan No. Description Data This document, and the ideas and designs incorporated herein, as an instrument of professional service, is the property of Crafton, Tull & Associates, Inc., and is not to be used, in whole or in part, for any other project, without the written authorization of Crafton, Tull & Associates, Inc. X5.1 AUCTION PROJECT NO: 10607602 OO RF ISSUE DATE 02/02/2045 ,oma THIS CONTACT: B.PETERSON DOCUMENT IS rn CHECKED BY: 2 PRELIMINARYIN NATURE AND IS NOT PRELIMINARY m AFINAL,SIGNED a PLANS z, AND SEALED 0 DOCUMENT ao 0 2015 Crafton, Tull& Associates, Inc. qty p� `' NollonbLsN SITE PLAN C 1.01 SET IRON PIN EASEMENT ----------------- LIGHT BOLLARD Nk POWER POLE CURB ■ TELEPHONE PEDESTAL 1206 0 TV PEDESTAL INTERMEDIATE CONTOUR Q MANHOLE 1206 INDEX CONTOUR o SANITARY SEWER UANOUT • GAS METER e: SANITARY SEWER LINE H GAS VALVE STORM SEWER PIPE 0 GAS LINE O x -x STRUCTURE NUMBER WATER LINE N WATER VALVE FIRE HYDRANT A`i"BLY UNDERGROUND TELEPHONE IN AIR RELEASE VALVE —moi 1 14 FIRE DEPARTMENT CONNECTION UNDERGROUND ELECTRIC 0 WATER METER i 1 OVERHEAD ELECTRIC 9 BACK FLOW PREENTER A REDUCER FIBER OPTIC PLUG VALVE ucry -- wry UNDERGROUND TELEVISION GRATED INLET -Z-4Z _.:SION DROP INLET CHAIN LINK FENCE WOOD FENCE BARBED WIREFENCE BUILDING SET BACK RIGHT OF WAY PROPERTY LINE ROAD CENTERLINE SITE ENGINEER: CRAFTON, TULL, SPARKS & ASSOCIATES, INC. 10825 FINANCIAL CENTER PARKWAY, SUITE 300 LITTLE ROCK, AR 72211 PHONE: 501.664.3245 FAX: 501.664.6704 SITE DEVELOPER: DAVID PREWETT BWWP VENTURES, LLC 220 NORTH KNOXVILLE RUSSELLVILLE, AR 72801 FES 2 2015 (479) 890-5232 PHONE (479) 880-6057 CELL REQUIRED PARKING: 41 (1 SPACE/400 SF) PROVIDED PARKING: 50 SPACES 10825 Financial Center Parkway, Suite 300 Little Rock, Arkansas 72211 00 Crafton Tull engineering I surveying 501.664.3245t 501.664.6704f www.craftontull.com CERTIFICATE OF AUTHORIZATION: ,nO'F AU�p CRAFTON, TULL & ASSOCIATES, INC. z o< No. 109 J ?C, q�'rgN5A5 EPK;IWE�R LOT 5 EPA TALLEY ROAD ADDITION 5 REMINGTON COVE LITTLE ROCK, ARKANSAS i8 I Key Plan No. Description Data This document, and the ideas and designs incorporated herein, as an instrument of professional service, is the property of Crafton, Tull & Associates, Inc., and is not to be used, in whole or in part, for any other project, without the written authorization of Crafton, Tull & Associates, Inc. X5.1 AUCTION PROJECT NO: 10607602 OO RF ISSUE DATE 02/02/2045 ,oma THIS CONTACT: B.PETERSON DOCUMENT IS rn CHECKED BY: 2 PRELIMINARYIN NATURE AND IS NOT PRELIMINARY m AFINAL,SIGNED a PLANS z, AND SEALED 0 DOCUMENT ao 0 2015 Crafton, Tull& Associates, Inc. qty p� `' NollonbLsN SITE PLAN C 1.01