HomeMy WebLinkAboutZ-7737 Map 3W
0' 60' 120
BASIS OF BEARING:
PACIS MON 2089
314
a
MICHAEL
MATCHETT
Legal Description
Part of the Southeast % of the Southeast % of Section 1,
Township 2 North, Range 15 West, Pulaski County, Arkansas being
more particularly described as follows;
Beginning at the Northeast corner of the Southeast !14 of the
Southeast Y4 of said Section 1; thence South 00'32'52" West
along the East line of said Southeast Y4 of the Southeast °4, a
distance of 918.21 feet to a point on the Northerly right-of-way
line of Arkansas State Highway 10 (160' R/W); thence North
55004'41" West along said right-of-way line, a distance of
447.07 feet; thence North 00'32'52" East leaving said
right-of-way line, a distance of 645.87 feet to a point on the
Southerly right-of-way line of Hood Road (50'R/W); thence
South 88'46'18" East along said right-of-way line, a distance
of 69.49 feet; thence North 79'44'18" East along said
right-of-way line, a distance of 115.79 feet to a point on the
North line of said Southeast 14 of the Southeast %; thence South
89'09'09" East leaving said right-of-way line, along said North
line, a distance of 185.77 feet to the Point of Beginning
containing 6.653 acres, more or less.
P101 K �e
ryvl (-'An4�
(Y"�Pljv VC cl � r
V:1 c�I1�:Ir 1\/1 �1-:::�
*Right of Way Monument
A Control Points
Set Iron Pin
Found Monument
® Gas Regulator
® Gas Riser
Q'p Gas Meter
® Clean Out
® Sanitary Sewer Manhole
® Telephone Pedestal
® Electric Meter
® Electric Box
-a- Power Pole
Guy Wire Anchor
Light Pole
(L Center Line
0 Flag Pole
q
rz
O
p�
A portion od this property lies within Zone A3 according to
Fire Hydrant
w�
Water Hydrant
Federal Flood Insurance Rate Malo Community Panel No.
Q Down Spout
® Water Meter
Da Water Valve
kx�
® Metal Drainage Grate
® Gate Post
Co
Ground Light
co
Y Sign
O
® Junction Box
o
Ck Handicap Parking
d
® Manhole
q
O Bollard
c\
® Mailbox
ground, or verbal communication from onsite utility personnel.
O
® RPZ Valve
CO QO ko
0 Tree
Surveyor is not responsible for existing underground utilities that
Q Vault
AC Air Conditioner
m
— Flow Direction
tzj
[:Q Flared End Section
y
Poi
UGT Underground Telephone
W
S Sanitary Sewer Main
a
E Overhead Electric
G Underground Gas
w Waterline
z
UGE Underground Electric
z
x Fence
O
(4
FO Fiber Optic
If,
Treeline
C)
Concrete
~'
O
Flood Information
w
A portion od this property lies within Zone A3 according to
w�
D
Federal Flood Insurance Rate Malo Community Panel No.
0501790235E, effective date, July 16, 1996.
C\?
Note:
o
y
All utilities shown per visible field evidence, lines marked on the
o
ground, or verbal communication from onsite utility personnel.
Surveyor is not responsible for existing underground utilities that
ro
m
are incorrectly located, omitted from or added to this plat.
tzj
w4
y