HomeMy WebLinkAboutZ-7668-A Staff AnalysisFILE NO.: Z -7668-B
NAME: Chardeaux Court Revised Short -form PD -R
LOCATION: Located at 12900 Hinson Road
DEVELOPER:
Rodney Chandler
P.O. Box 22021
Little Rock, AR 72221
ENGINEER:
Central Arkansas Surveying Company
1012 Autumn Road, Suite 1
Little Rock, AR 72211
AREA: 3.68 Acres NUMBER OF LOTS: 13 FT. NEW STREET: 163 LF
CURRENT ZONING: PD -R
ALLOWED USES: Single-family Residential
PROPOSED ZONING: PD -R
PROPOSED USE: Patio Zero Lot Line Single-family Residential
VARIANCESM/AIVERS REQUESTED: None requested.
BACKGROUND:
The Little Rock Planning Commission reviewed a request to allow the development of a
1.85 -acre tract with ten single-family patio homes at their July 15, 2004, Public Hearing.
The Little Rock Board of Directors approved the request by the adoption of Ordinance
No. 19,162 at their August 17, 2004, Public Hearing.
Chardeaux Court was proposed as ten upscale residential patio homes. The proposed
homes consisted of three bedrooms, great room, two full baths, formal dining, kitchen
with breakfast area and attached double garage. All homes were to have a French
European exterior elevation with an accented decor and feature amenities that were
standard for upscale patio homes of this style. Interior amenities included granite slab
kitchen countertops, flooring of wood, stone, tile and carpet, marble baths, raised
FILE NO.: Z -7668-B f Cont.
ceilings with stacked crown molding and recessed can lighting to provide elegant
interior features.
Exterior features included masonry with structural accents and details such as brick on
all four sides, precise keystones, brick quoins, arched windows, architectural roof
shingles, landscaped lawns with zoysia turf and automatic sprinkler systems. Roof pitch
elevations were proposed as a minimum of 12/12 to enhance the aesthetics of the
development. Patio homes were to have a minimum front setback of eighteen feet and
a rear setback of ten feet with wooden privacy fencing was planned for each home to
promote an upscale environment and enhance street scene.
Patio homes in Charadeaux Court were proposed to range in square footage from 2,500
to 1,600 heated and cooled space. It was anticipated that homes would sell in the
$120.00 to $130.00 per square foot price category given that Chardeaux Court was
proposed as a gated upscale patio home development. A bill of assurance was
proposed to maintain and to protect the values of properties in and around Chardeaux
Court.
The entrance to Chardeaux Court was proposed as a brick entrance with wrought iron
railing, accent lighting and extensive landscape with substantial green space to promote
an appealing environment that complimented the development. Additionally, all lawn
and all common areas were to be maintained by the Property Owners Association. The
common maintenance of all the residences in Chardeaux Court reinforced the quality
that was planned, and would continue to be stressed throughout the residential
development.
A. PROPOSAL/REQUEST — APPLICANT'S STATEMENT:
The applicant has now acquired an adjacent 1.86 acres and is now proposing to
revise the previously approved PD -R to allow the development of 17th Century
European architecture homes with 21St Century construction to consist of 13 zero
lot line patio homes. The proposed homes will consist of three or four bedrooms,
great room, media room, two full and one-half bath, dining area, kitchen with
breakfast area, double attached garage and full compliment of built-in stainless
steel appliances. All the homes will have a French European exterior with
accented decor and feature amenities that generally are standard for an upscale
development. Interior amenities will include travertine tile, hardwood flooring,
granite slab kitchen counter tops, marble bathrooms and raised ceilings with
stacked crown molding and recessed can lighting.
Exterior features include masonry, natural stone with structural accents and
details such as brick on all four sides, precast keystones, brick quoins, arched
windows, architectural roof shingles, landscaped lawns with zoysia turf and
automatic sprinkler systems. Roof pitch elevations will be a minimum of 12/12 to
enhance the aesthetics of the development. A wooden privacy fence is planned
for the east and north sides of the development.
2
FILE NO.: Z -7668-B !Cont.
The developer has indicated the homes will range in square footages from 2200
to 3500 square feet of heated and cooled spaces. The developer has indicated
the homes will range in price from $138.00 to $145.00 per square foot. The
development is proposed as a gated upscale patio home community.
Entrances to the development will have an old world European guard house, rock
entrance with wrought iron railing, accent lighting and extensive landscape with
substantial green space to promote an appealing environment that compliments
the development. The property owners association will maintain all lawns and
common areas. The common maintenance of all the residences in the
development reinforces the quality that has been planned, and will continue to be
stressed throughout the residential development.
The proposed site plan indicates an average lot size of 7,689 square feet or 0.18
acres with a minimum lot size of 6,944 square feet or 0.16 acres. As previously
stated, the applicant has indicated the development will consist of one side yard
being a zero lot line setback with the remaining side yard setback of five feet.
The applicant has indicated the rear yard setback will be 20 -feet for proposed
Lots 1 — 7 and 30 -feet for proposed Lots 8 —13.
The applicant is requesting a Zero Lot Line plat per Section 31-234 of the City of
Little Rock Subdivision Ordinance and per the ordinance requirement has
indicated the maximum buildable area specifying the zero lot line for each lot.
The applicant has also indicated building lines per Section 31-256(4), which allow
for residential lots defined as "Contemporary Lots" to designate building lines.
Per these two sections of the ordinance, there are no variances for lot
development standards being requested.
The applicant has indicated there is not a Bill of Assurance in effect for this
parcel of property.
B. EXISTING CONDITIONS:
The site is vacant and relatively flat with a major drainage channel running along
the southern portion of the site, near Hinson Road. There is an unimproved
driveway located along the eastern boundary of the site with single-family homes
located to the east, north and west of the site. Pleasant Valley Estates
Subdivision, a gated subdivision, is located to the west of the site and the
Pleasant Valley Subdivision is located to the north and northeast of the site.
Other uses in the area include Pulaski Academy School and the Fellowship Bible
Church to the Southeast. A zero lot 'line subdivision with attached units (in the
Chelsea Square Addition) is located to the west of the site and the Carmel Valley
Subdivision is located to the northwest of the site.
3
FILE NO.: Z -7668-B (Cont.
C
C
L
NEIGHBORHOOD COMMENTS:
As of this writing, Staff has received one phone call from an area resident. The
Rainwood Cove Neighborhood Association, the Pleasant Valley Property Owners
Association, the Hillsborough Property Owners Association, all property owners
within 200 feet of the site and all residents, who could be identified, within 300
feet of the site were notified of the Public Hearing.
ENGINEERING COMMENTS:
1. From a traffic safety standpoint, the new street entrance should line up with
Martha Drive to the west.
2. Hinson Road is classified on the Master Street Plan as a minor arterial.
Dedication of right-of-way 45 -feet from centerline will be required (shown on
the plan).
3. Repair or replace any curb and gutter or sidewalk that is damaged in the
public right-of-way prior to occupancy.
4. A grading permit in accordance with Section 29-186 (c) and (d) will be
required prior to any land clearing or grading activities at the site. Site
grading and drainage plans will need to be submitted and approved prior to
the start of construction.
5. A special Grading Permit for Flood Hazard Areas will be required per Section
8-283 prior to construction. For lots located in the floodplain, a minimum
finish floor elevation must be shown on the plat.
6. In accordance with Section 31-176, floodway areas must be shown as
floodway easements or be dedicated to the public. In addition, a 25 -foot wide
access easement is required adjacent to the floodway boundary as shown on
the plan.
7. Alteration oU the floodway for street construction will require flood map
revisions. Obtain conditional approval from Public Works and the Federal
Emergency Management Agency. A permanent crossing must be
constructed prior to start of any work on the subdivision.
8. Alteration of the watercourse will require approval from the Little Rock District
of the US Army Corps of Engineers prior to the start of work.
9. Prepare a letter of pending development addressing streetlights as required
by Section 31-403 of the Little Rock Code of Ordinances. Contact Traffic
Engineering at (501) 379-1813 for additional information regarding street light
requirements.
UTILITIES AND FIRE DEPARTMENT/COUNTY PLANNING:
Wastewater: Sewer main extension required with easements is service is
required for the project. Relocation of existing eight -inch sewer main required at
Developer's expense. Six inch and eight inch service lines shown are not a part
of the Little Rock Wastewater Utility System and cannot be used to provide
service to any part of this development. Contact Little Rock Wastewater Utility at
688-1414 for additional information.
2
LE NO.: Z -7668-B
Entergy: A ten -foot under ground or a 30 -foot overhead easement is required
along the lot fronts adjacent to the proposed street. Contact Entergy at 954-5158
for additional information.
Center -Point Ener : No comment received.
SBC: No comment received.
Central Arkansas Water: All Central Arkansas Water requirements in effect at the
time of request for water service must be met. There is an existing 8 -inch (not 6 -
inch) water main and fire hydrant in an existing waterline easement in this area.
(Instrument No. 2000062944) A Capital Investment Charge based on the size of
connection(s) will apply to this project in addition to normal charges. A water
main extension will be required in order to provide service to this property. If
there are facilities that need to be adjusted and/or relocated, contact Central
Arkansas Water. That work would be done at the expense of the developer. This
development will have minor impact on the existing water distribution system.
Proposed water facilities will be sized to provide adequate pressure and fire
protection.
Fire Department: Place fire hydrants per code. Maintain a 20 -foot gate opening
into the site. Contact the Little Rock Fire Department at 918-3700 for additional
information.
County Planning: No comment.
CATA: The site is not located on a CATA Bus Route.
F. ISSUES/TECHNICAL/DESIGN:
Planning Division: This request is located in the River Mountain Planning
District. The Land Use Plan shows Single Family for this property. The applicant
has applied for a revision to a previously approved PRD for a construction of
additional single-family homes on recently acquired land adjacent to the
approved residential development.
The request does not require a change to the Land Use Plan.
Master Street Plan: Hinson Road is shown as a Minor Arterial on the Master
Street Plan and may require dedication of right-of-way and street improvements.
A Minor Arterial provides connections to and through an urban area and their
primary function is to provide short distance travel within the urbanized area.
A Class I Bikeway is shown alongside Hinson Road. A Class I Bikeway is built
separate from or alongside a road. Additional paving and right of way may be
required.
l•1
FILE NO.: Z-7668-8 Cont.
City Recognized Neighborhood Action Plan: The applicant's property lies in the
area covered by the River Mountain Neighborhood Action Plan. The Residential
Development Goal listed an objective of "Develop neo -traditional neighborhoods
(pedestrian and bicycle friendly neighborhoods, which are less dependant on
automobiles) in areas that have not yet developed. It also listed action
statements of 1) "Enforce the construction of sidewalks with all types of
development", 2) "Insure that physical continuity of sidewalks so that sidewalks
built on the same side of the street connect without gaps and that sidewalks built
on opposite sides of the street are connected with ADA accessible crosswalks",
3) "Require developers to install underground utilities in all new subdivisions, and
4) "Require street lighting to be in place in new subdivisions at the time streets
are opened. The additional development of the site should be sensitive to the
action plan's residential development goals.
Landscape: No comment.
G. SUBDIVISION COMMITTEE COMMENT: (December 29, 2004)
The applicant's representatives were present representing the request. Staff
stated the developer was previously approved for the development of a smaller
area with fewer homes but additional land to the east and north had been
secured. Staff stated the proposal now included 3.68 acres and 13 new homes
and the previous approval included 1.85 acres and 10 homes. Staff stated the
developer was proposing zero lot line homes in the development. Staff stated
there were additional items necessary to complete the review process.
Staff stated since the proposal included the development of the site with a zero
lot line homes, the plat needed to include the maximum buildable area of each lot
with the zero lot line specified. Staff also stated if the development were to be
phased, a phasing plan was necessary. Staff requested details of any proposed
fencing including height; construction material and location.
Public Works comments were addressed. Staff stated the new street entrance
should align with Martha Drive, located south of Hinson Road. Staff also stated
dedication would be required on Hinson Road to satisfy the Master Street Plan
requirement. Staff noted there were concerns with the floodway areas. Staff
stated all floodways should be indicated as an easement or be dedicated to the
City. Staff also stated alteration of the floodway for street construction would
require flood map revisions and approval from Public Works and Federal
Emergency Management Agency.
Staff noted comments from the various other reporting departments and
agencies indicating the applicant should contact them individually for further
clarification. There was no further discussion of the item. The Committee then
forwarded the item to the full Commission for final action.
A
FILE NO.: Z-7658-8 (Cont.)
H. ANALYSIS:
The applicant submitted a revised plan to staff addressing most of the issues
raised at the December 29, 2004, Subdivision Committee meeting. The
applicant has met with Public Works staff to resolve their concerns related to the
street entry point and the floodway issues. The applicant has indicated the
roadway will be constructed outside the floodway as was previously proposed
and a map revision is no longer needed. The developer has indicated a
dedication of the floodway and a 25 -foot easement adjacent to the floodway per
the City's request. The applicant has also indicated a dedication of right-of-way
along Hinson Road per the Master Street Plan requirement.
The proposed site plan indicates the maximum buildable area for each lot with
the zero lot line specified. The applicant has also indicated the development will
be constructed in one phase. The site plan includes the placement of fencing
along Hinson Road. The fence is proposed as a six-foot wrought iron fence.
Fencing along the eastern, western and northern property lines are also
proposed as six feet in height and to be constructed of wood, brick, masonry or
wrought iron. The applicant has indicated the development will be gated and
has indicated a guard shack and call box on the proposed site plan. The call box
is located 71.5 feet from the property line, per the request of Public Works. The
applicant has also indicated the gates will be constructed at 16.0 feet in width.
Staff recommends the gates maintain a 20 -foot gate opening to allow for
emergency access.
The applicant is requesting a Zero Lot Line plat per Section 31-234 of the City of
Little Rock Subdivision Ordinance and per the ordinance requirement has
indicated the maximum buildable area specifying the zero lot line for each lot.
The applicant has also indicated building lines per Section 31-256(4), which allow
for residential lots defined as "Contemporary Lots" to designate building lines.
The applicant has indicated a generalized site plan showing the proposed
locations and dimensions of all buildings, accessory uses and other
improvements. The platted building lines are shown on all sides of each lot for
the purposed of delineating the maximum buildable area of each lot and the zero
lot line yard has been specified. The ordinance also requires a minimum lot
width of 35 feet and 4,000 square feet in area. The applicant has indicated the
average lot size as 7,689 and the minimum lot size as 6,944. The minimum lot
width proposed is 50 -feet. The indicated lot area and lot widths are more than
adequate to meet the typical minimum ordinance requirement.
The applicant has indicated a single development sign with a maximum height of
six feet and a total length of fourteen feet. The sign letters are proposed as six
inches. The sign is proposed with brick and rock columns and a pre -cast cap
and spheres. Staff is supportive of the applicant's requested signage.
There are single-family homes located to the north of this site currently accessing
their homes through an access easement located on the site. The applicant has
7
FILE NO.: Z -7668-B (Cont.
indicated access will be provided to properties located to the north of the site
through the proposed subdivision.
To staff's knowledge there are no outstanding issues associated with the
proposed request. The applicant is proposing a single-family development at a
density of 3.5 units per acre. Single-family per the City's Future Land Use Plan
allows development of single-family homes at a density not greater than five units
per acre. Staff feels the proposed development have should minimal to no
adverse impact on adjoining properties.
STAFF RECOMMENDATION:
Staff recommends approval of the request subject to compliance with the
conditions outlined in paragraphs D, E and F of the above report.
Staff recommends the proposed gates maintain a 20 -foot gate opening to allow
for emergency access.
PLANNING COMMISSION ACTION: (JANUARY 20, 2005)
The applicant was present representing the request. There were no registered
objectors present. Staff presented the item with a recommendation of approval of the
request subject to compliance with the conditions outlined in paragraphs D, E and F of
the above report. Staff also presented a recommendation the proposed gates maintain
a 20 -foot gate opening to allow for emergency access.
There was no further discussion of the item. The chair entertained a motion to place the
item on the consent agenda for approval. The motion carried by a vote of 10 ayes, 0 no
and 1 absent.
E
January 20, 2005
ITEM NO.: 19
NAME: Chardeaux Court Revised Short -form PD -R
LOCATION: Located at 12900 Hinson Road
DEVELOPER:
Rodney Chandler
P.O. Box 22021
Little Rock, AR 72221
ENGINEER -
Central Arkansas Surveying Company
1012 Autumn Road, Suite 1
Little Rock, AR 72211
FILE NO.: Z -7668-B
AREA: 3:68 Acres NUMBER OF LOTS: 13 FT. NEW STREET: 163 LF
CURRENT ZONING: PD -R
ALLOWED USES: Single-family Residential
PROPOSED ZONING: PD -R
PROPOSED USE: Patio Zero Lot Line Single-family Residential
VARIAN CESNVAIVERS REQUESTED: None requested.
BACKGROUND:
The Little Rock Planning Commission reviewed a request to allow the development of a
1.85 -acre tract with ten single-family patio homes at their July 15, 2004, Public Hearing.
The Little Rock Board of Directors approved the request by the adoption of Ordinance
No. 19,162 at their August 17, 2004, Public Hearing.
Chardeaux Court was proposed as ten upscale residential patio homes. The proposed
homes consisted of three bedrooms, great room, two full baths, formal dining, kitchen
with breakfast area and attached double garage. All homes were to have a French
European exterior elevation with an accented decor and feature amenities that were
standard for upscale patio homes of this style. Interior amenities included granite slab
January 20, 2005
SUBDIVISION
ITEM NO.: 19 (Cont.) FILE NO.: Z -
kitchen countertops, flooring of wood, stone, tile and carpet, marble baths, raised
ceilings with stacked crown molding and recessed can lighting to provide elegant
interior features.
Exterior features included masonry with structural accents and details such as brick on
all four sides, precise keystones, brick quoins, arched windows, architectural roof
shingles, landscaped lawns with zoysia turf and automatic sprinkler systems. Roof pitch
elevations were proposed as a minimum of 12/12 to enhance the aesthetics of the
development. Patio homes were to have a minimum front setback of eighteen feet and
a rear setback of ten feet with wooden privacy fencing was planned for each home to
promote an upscale environment and enhance street scene.
Patio homes in Charadeaux Court were proposed to range in square footage from 2,500
to 1,600 heated and cooled space. It was anticipated that homes would sell in the
$120.00 to $130.00 per square foot price category given that Chardeaux Court was
proposed as a gated upscale patio home development. A bill of assurance was
proposed to maintain and to protect the values of properties in and around Chardeaux
Court.
The entrance to Chardeaux Court was proposed as a brick entrance with wrought iron
railing, accent lighting and extensive landscape with substantial green space to promote
an appealing environment that complimented the development. Additionally, all lawn
and all common areas were to be maintained by the Property Owners Association. The
common maintenance of all the residences in Chardeaux Court reinforced the quality
that was planned, and would continue to be stressed throughout the residential
development.
A. PROPOSAUREQUEST — APPLICANT'S STATEMENT:
The applicant has now acquired an adjacent 1.86 acres and is now proposing to
revise the previously approved PD -R to allow the development of 17th Century
European architecture homes with 21St Century construction to consist of 13 zero
lot line patio homes. The proposed homes will consist of three or four bedrooms,
great room, media room, two full and one-half bath, dining area, kitchen with
breakfast area, double attached garage and full compliment of built-in stainless
steel appliances. All the homes will have a French European exterior with
accented decor and feature amenities that generally are standard for an upscale
development. Interior amenities will include travertine tile, hardwood flooring,
granite slab kitchen counter tops, marble bathrooms and raised ceilings with
stacked crown molding and recessed can lighting.
Exterior features include masonry, natural stone with structural accents and
details such as brick on all four sides, precast keystones, brick quoins, arched
windows, architectural roof shingles, landscaped lawns with zoysia turf and
automatic sprinkler systems. Roof pitch elevations will be a minimum of 12/12 to
2
January 20, 2005
SUBDIVISION
ITEM NO_: 19 (Cont.) FILE NO.: Z -7668-B
enhance the aesthetics of the development. A wooden privacy fence is planned
for the east and north sides of the development.
The developer has indicated the homes will range in square footages from 2200
to 3500 square feet of heated and cooled spaces. The developer has indicated
the homes will range in price from $138.00 to $145.00 per square foot. The
development is proposed as a gated upscale patio home community.
Entrances to the development will have an old world European guard house, rock
entrance with wrought iron railing, accent lighting and extensive landscape with
substantial green space to promote an appealing environment that compliments
the development. The property owners association will maintain all lawns and
common areas. The common maintenance of all the residences in the
development reinforces the quality that has been planned, and will continue to be
stressed throughout the residential development.
The proposed site plan indicates an average lot size of 7,689 square feet or 0.18
acres with a minimum lot size of 6,944 square feet or 0.16 acres. As previously
stated, the applicant has indicated the development will consist of one side yard
being a zero lot line setback with the remaining side yard setback of five feet.
The applicant has indicated the rear yard setback will be 20 -feet for proposed
Lots 1 — 7 and 30 -feet for proposed Lots 8 — 13.
The applicant is requesting a Zero Lot Line plat per Section 31-234 of the City of
Little Rock Subdivision Ordinance and per the ordinance requirement has
indicated the maximum buildable area specifying the zero lot line for each lot.
The applicant has also indicated building lines per Section 31-256(4), which allow
for residential lots defined as "Contemporary Lots" to designate building lines.
Per these two sections of the ordinance, there are no variances for lot
development standards being requested.
The applicant has indicated there is not a Bill of Assurance in effect for this
parcel of property.
B. EXISTING CONDITIONS:
The site is vacant and relatively flat with a major drainage channel running along
the southern portion of the site, near Hinson Road. There is an unimproved
driveway located along the eastern boundary of the site with single-family homes
located to the east, north and west of the site. Pleasant Valley Estates
Subdivision, a gated subdivision, is located to the west of the site and the
Pleasant Valley Subdivision is located to the north and northeast of the site.
Other uses in the area include Pulaski Academy School and the Fellowship Bible
Church to the Southeast. A zero lot line subdivision with attached units (in the
KI
January 20, 2005
SUBDIVISION
11110-LYA10I;9M
FILE NO.: Z -7668-B
Chelsea Square Addition) is located to the west of the site and the Carmel Valley
Subdivision is located to the northwest of the site.
C. NEIGHBORHOOD COMMENTS:
As of this writing, Staff has received one phone call from an area resident. The
Rainwood Cove Neighborhood Association, the Pleasant Valley Property Owners
Association, the Hillsborough Property Owners Association, all property owners
within 200 feet of the site and all residents, who could be identified, within 300
feet of the site were notified of the Public Hearing.
D. ENGINEERING COMMENTS:
1. From a traffic safety standpoint, the new street entrance should line up with
Martha Drive to the west.
2. Hinson Road is classified on the Master Street Plan as a minor arterial.
Dedication of right-of-way 45 -feet from centerline will be required (shown on
the plan).
3. Repair or replace any curb and gutter or sidewalk that is damaged in the
public right-of-way prior to occupancy.
4. A grading permit in accordance with Section 29-186 (c) and (d) will be
required prior to any land clearing or grading activities at the site. Site
grading and drainage plans will need to be submitted and approved prior to
the start of construction.
5. A special Grading Permit for Flood Hazard Areas will be required per Section
8-283 prior to construction. For lots located in the floodplain, a minimum
finish floor elevation must be shown on the plat.
6. In accordance with Section 31-176, floodway areas must be shown as
floodway easements or be dedicated to the public. In addition, a 25 -foot wide
access easement is required adjacent to the floodway boundary as shown on
the plan.
7. Alteration of the floodway for street construction will require flood map
revisions. Obtain conditional approval from Public Works and the Federal
Emergency Management Agency. A permanent crossing must be
constructed prior to start of any work on the subdivision.
8. Alteration of the watercourse will require approval from the Little Rock District
of the US Army Corps of Engineers prior to the start of work.
9. Prepare a letter of pending development addressing streetlights as required
by Section 31-403 of the Little Rock Code of Ordinances. Contact Traffic
Engineering at (501) 379-1813 for additional information regarding street light
requirements.
4
January 20, 2005
SUBDIVISION
ITEM NO.: 19 (Cont.) FILE NO.: Z -7668-B
E. UTILITIES AND FIRE DEPARTMENT/COUNTY PLANNING:
Wastewater: Sewer main extension required with easements is service is
required for the project. Relocation of existing eight -inch sewer main required at
Developer's expense. Six inch and eight inch service lines shown are not a part
of the Little Rock Wastewater Utility System and cannot be used to provide
service to any part of this development. Contact Little Rock Wastewater Utility at
688-1414 for additional information.
Entergy: A ten -foot under ground or a 30 -foot overhead easement is required
along the lot fronts adjacent to the proposed street. Contact Entergy at 954-5158
for additional information.
Center -Point Energy: No comment received.
SBC: No comment received.
Central Arkansas Water: All Central Arkansas Water requirements in effect at the
time of request for water service must be met. There is an existing 8 -inch (not 6 -
inch) water main and fire hydrant in an existing waterline easement in this area.
(Instrument No. 2000062944) A Capital Investment Charge based on the size of
connection(s) will apply to this project in addition to normal charges. A water
main extension will be required in order to provide service to this property. If
there are facilities that need to be adjusted and/or relocated, contact Central
Arkansas Water. That work would be done at the expense of the developer. This
development will have minor impact on the existing water distribution system.
Proposed water facilities will be sized to provide adequate pressure and fire
protection.
Fire Department: Place fire hydrants per code. Maintain a 20 -foot gate opening
into the site. Contact the Little Rock Fire Department at 918-3700 for additional
information.
County Planning: No comment.
CATA: The site is not located on a CATA Bus Route.
F. ISSUES/TECHNICAUDESIGN:
Planning Division: This request is located in the River Mountain Planning
District. The Land Use Plan shows Single Family for this property. The applicant
has applied for a revision to a previously approved PRD for a construction of
additional single-family homes on recently acquired land adjacent to the
approved residential development.
5
January20, 2005
SUBDIVISION
ITEM NO.: 19 (Cont.) FILE NO.: Z -7668-B
The request does not require a change to the Land Use Plan.
Master Street Plan: Hinson Road is shown as a Minor Arterial on the Master
Street Plan and may require dedication of right-of-way and street improvements.
A Minor Arterial provides connections to and through an urban area and their
primary function is to provide short distance travel within the urbanized area.
A Class I Bikeway is shown alongside Hinson Road. A Class I Bikeway is built
separate from or alongside a road. Additional paving and right of way may be
required.
City Recoc
jnized Neighborhood Action Plan: The applicant's property lies in the
area covered by the River Mountain Neighborhood Action Plan. The Residential
Development Goal listed an objective of "Develop neo -traditional neighborhoods
(pedestrian and bicycle friendly neighborhoods, which are less dependant on
automobiles) in areas that have not yet developed. It also listed action
statements of 1) "Enforce the construction of sidewalks with all types of
development", 2) "Insure that physical continuity of sidewalks so that sidewalks
built on the same side of the street connect without gaps and that sidewalks built
on opposite sides of the street are connected with ADA accessible crosswalks",
3) "Require developers to install underground utilities in all new subdivisions, and
4) "Require street lighting to be in place in new subdivisions at the time streets
are opened. The additional development of the site should be sensitive to the
action plan's residential development goals.
Landscape: No comment.
G. SUBDIVISION COMMITTEE COMMENT: (December 29, 2004)
The applicant's representatives were present representing the request. Staff
stated the developer was previously approved for the development of a smaller
area with fewer homes but additional land to the east and north had been
secured. Staff stated the proposal now included 3.68 acres and 13 new homes
and the previous approval included 1.85 acres and 10 homes. Staff stated the
developer was proposing zero lot line homes in the development. Staff stated
there were additional items necessary to complete the review process.
Staff stated since the proposal included the development of the site with a zero
lot line homes, the plat needed to include the maximum buildable area of each lot
with the zero lot line specified. Staff also stated if the development were to be
phased, a phasing plan was necessary. Staff requested details of any proposed
fencing including height; construction material and location.
Public Works comments were addressed. Staff stated the new street entrance
should align with Martha Drive, located south of Hinson Road. Staff also stated
0
January 20, 2005
.qI IRni\/IRInN
ITEM NO.: 19 Cont. FILE NO.: Z -7668-B
dedication would be required on Hinson Road to satisfy the Master Street Plan
requirement. Staff noted there were concerns with the floodway areas. Staff
stated all floodways should be indicated as an easement or be dedicated to the
City. Staff also stated alteration of the floodway for street construction would
require flood map revisions and approval from Public Works and Federal
Emergency Management Agency.
Staff noted comments from the various other reporting departments and
agencies indicating the applicant should contact them individually for further
clarification. There was no further discussion of the item. The Committee then
forwarded the item to the full Commission for final action.
H. ANALYSIS:
The applicant submitted a revised plan to staff addressing most of the issues
raised at the December 29, 2004, Subdivision Committee meeting. The
applicant has met with Public Works staff to resolve their concerns related to the
street entry point and the floodway issues. The applicant has indicated the
roadway will be constructed outside the floodway as was previously proposed
and a map revision is no longer needed. The developer has indicated a
dedication of the floodway and a 25 -foot easement adjacent to the floodway per
the City's request. The applicant has also indicated a dedication of right-of-way
along Hinson Road per the Master Street Plan requirement.
The proposed site plan indicates the maximum buildable area for each lot with
the zero lot line specified. The applicant has also indicated the development will
be constructed in one phase. The site plan includes the placement of fencing
along Hinson Road. The fence is proposed as a six-foot wrought iron fence.
Fencing along the eastern, western and northern property lines are also
proposed as six feet in height and to be constructed of wood, brick, masonry or
wrought iron. The applicant has indicated the development will be gated and
has indicated a guard shack and call box on the proposed site plan. The call box
is located 71.5 feet from the property line, per the request of Public Works. The
applicant has also indicated the gates will be constructed at 16.0 feet in width.
Staff recommends the gates maintain a 20 -foot gate opening to allow for
emergency access.
The applicant is requesting a Zero Lot Line plat per Section 31-234 of the City of
Little Rock Subdivision Ordinance and per the ordinance requirement has
indicated the maximum buildable area specifying the zero lot line for each lot.
The applicant has also indicated building lines per Section 31-256(4), which allow
for residential lots defined as "Contemporary Lots" to designate building lines.
The applicant has indicated a generalized site plan showing the proposed
locations and dimensions of all buildings, accessory uses and other
improvements. The platted building lines are shown on all sides of each lot for
7
January 20, 2005
SUBDIVISION
ITEM NO.: 19 Cont. FILE NO.: Z -7668-B
the purposed of delineating the maximum buildable area of each lot and the zero
lot line yard has been specified. The ordinance also requires a minimum lot
width of 35 feet and 4,000 square feet in area. The applicant has indicated the
average lot size as 7,689 and the minimum lot size as 6,944. The minimum lot
width proposed is 50 -feet. The indicated lot area and lot widths are more than
adequate to meet the typical minimum ordinance requirement.
The applicant has indicated a single development sign with a maximum height of
six feet and a total length of fourteen feet. The sign letters are proposed as six
inches. The sign is proposed with brick and rock columns and a pre -cast cap
and spheres. Staff is supportive of the applicant's requested signage.
There are single-family homes located to the north of this site currently accessing
their homes through an access easement located on the site. The applicant has
indicated access will be provided to properties located to the north of the site
through the proposed subdivision.
To staff's knowledge there are no outstanding issues associated with the
proposed request. The applicant is proposing a single-family development at a
density of 3.5 units per acre. Single-family per the City's Future Land Use Plan
allows development of single-family homes at a density not greater than five units
per acre. Staff feels the proposed development have should minimal to no
adverse impact on adjoining properties.
I. STAFF RECOMMENDATION:
Staff recommends approval of the request subject to compliance with the
conditions outlined in paragraphs D, E and F of the above report.
Staff recommends the proposed gates maintain a 20 -foot gate opening to allow
for emergency access.
PLANNING COMMISSION ACTION: (JANUARY 20, 2005)
The applicant was present representing the request. There were no registered
objectors present. Staff presented the item with a recommendation of approval of the
request subject to compliance with the conditions outlined in paragraphs D, E and F of
the above report. Staff also presented a recommendation the proposed gates maintain
a 20 -foot gate opening to allow for emergency access.
There was no further discussion of the item. The chair entertained a motion to place the
item on the consent agenda for approval. The motion carried by a vote of 10 ayes, 0 no
and 1 absent.
ITEM NO.: 19.
NAME: Chardeau Court Revised Short -form PD -R
LOCATION: located at 12900 Hinson Road
Planning Staff Comments:
FILE NO.: Z -7668-B
1. Provide notification of property owners located within 200 -feet of the site, complete
with the certified abstract list, notice form with affidavit executed and proof of
mailing.
2. Provide on the proposed site plan the proposed locations and dimensions of all
buildings, accessory uses and other improvements. Platted building lines shall be
shown on all sides of each lot for purposes of delineating the maximum buildable
area of each lot and specify the zero -lot -line yard.
3. General Note #3 appears to be incorrect.
4. Provide a phasing plan, if applicable.
5. Provide details of any proposed fencing (location, height, construction material).
Variance/Waivers:
Public Works:
1. From a traffic safety standpoint, the new street entrance should line up with Martha
Drive to the west.
2. Hinson Road is classified on the Master Street Plan as a minor arterial. Dedication
of right-of-way 45 -feet from centerline will be required (shown on the plan).
3. Repair or replace any curb and gutter or sidewalk that is damaged in the public right-
of-way prior to occupancy.
4. A grading permit in accordance with Section 29-186 (c) and (d) will be required prior
to any land clearing or grading activities at the site. Site grading and drainage plans
will need to be submitted and approved prior to the start of construction.
5. A special Grading Permit for Flood Hazard Areas will be required per Section 8-283
prior to construction. For lots located in the floodplain, a minimum finish floor
elevation must be shown on the plat.
6. In accordance with Section 31-176, floodway areas must be shown as floodway
easements or be dedicated to the public. In addition, a 25 -foot wide access
easement is required adjacent to the floodway boundary as shown on the plan.
7. Alteration of the floodway for street construction will require flood map revisions.
Obtain conditional approval from Public Works and the Federal Emergency
Management Agency. A permanent crossing must be constructed prior to start of
any work on the subdivision.
8. Alteration of the water course will require approval from the Little Rock District of the
US Army Corps of Engineers prior to the start of work.
9. Prepare a letter of pending development addressing street lights as required by
Section 31-403 of the Little Rock Code of Ordinances. Contact Traffic Engineering
at (501) 379-1813 for additional information regarding street light requirements.
Utilities and Fire Department/County Planning:
Wastewater: Sewer main extension required with easements is service is required for
the project. Relocation of existing eight inch sewer main required at Developer's
expense. Six inch and eight inch service lines shown are not a part of the Little Rock
Wastewater Utility System and cannot be used to provide service to any part of this
development. Contact Little Rock Wastewater Utility at 688-1414 for additional
information.
Entergy: No comment received.
Center -Point Energy_: No comment received.
SBC: No comment received.
Central Arkansas Water: All Central Arkansas Water requirements in effect at the time
of request for water service must be met. There is an existing 8 -inch (not 6 -inch) water
main and fire hydrant in an existing waterline easement in this area. (Instrument No.
2000062944) A Capital Investment Charge based on the size of connection(s) will apply
to this project in addition to normal charges. A water main extension will be required in
order to provide service to this property. If there are facilities that need to be adjusted
and/or relocated, contact Central Arkansas Water. That work would be done at the
expense of the developer. This development will have minor impact on the existing
water distribution system. Proposed water facilities will be sized to provide adequate
pressure and fire protection.
Fire Department:
County _Planning: No comment.
CATA: The site is not located on a CATA Bus Route.
Planning Division: This request is located in the River Mountain Planning District. The
Land Use Plan shows Single Family for this property. The applicant has applied for a
revision to a previously approved PRD for a construction of additional single-family
homes on recently acquired land adjacent to the approved residential development.
The request does not require a change to the Land Use Plan.
Master Street Plan: Hinson Road is shown as a Minor Arterial on the Master Street
Plan and may require dedication of right-of-way and street improvements. A Minor
Arterial provides connections to and through an urban area and their primary function is
to provide short distance travel within the urbanized area.
A Class I Bikeway is shown alongside Hinson Road. A Class I Bikeway is built separate
from or alongside a road. Additional paving and right of way may be required.
City Recognized Neighborhood Action Plan: The applicant's property lies in the area
covered by the River Mountain Neighborhood Action Plan. The Residential
Development Goal listed an objective of "Develop neo -traditional neighborhoods
(pedestrian and bicycle friendly neighborhoods, which are less dependant on
automobiles) in areas that have not yet developed. It also listed action statements of 1)
"Enforce the construction of sidewalks with all types of development", 2) "Insure that
physical continuity of sidewalks so that sidewalks built on the same side of the street
connect without gaps and that sidewalks built on opposite sides of the street are
connected with ADA accessible crosswalks", 3) "Require developers to install
underground utilities in all new subdivisions, and 4) "Require street lighting to be in
place in new subdivisions at the time streets are opened. The additional development
of the site should be sensitive to the action plan's residential development goals.
Landscape. No comment.
Revised plat/plan: Submit four (4) copies of a revised preliminary plan (to include the
additional information as noted above) to staff on Wednesday, December 29, 2004.