HomeMy WebLinkAboutZ-7500-D Staff AnalysisFebruary 14, 2008
ITEM NO.: F FILE NO.: LU08-01-01
Name: Land Use Plan Amendment - River Mountain Planning District
Location: North of Cantrell Road, west of Pinnacle Valley Road and north of Taylor
Loop Road
Request: Transition, Mixed Office Commercial and Single Family to Commercial
Source: John Rees
PROPOSAL/REQUEST:
The applicant has requested this item be deferred to the February 14, 2008 agenda.
PLANNING COMMISSION ACTION:
(JANUARY 3, 2008)
The item was placed on consent agenda for deferral to February 14, 2008. By a vote
10 for, 0 against the item was deferred.
PROPOSAL / REQUEST:
The applicant has requested this item be withdrawn from consideration.
PLANNING COMMISSION ACTION:
(FEBRUARY 14, 2008)
The item was placed on consent agenda for withdrawal. By a vote of 8 for and
3 against the consent agenda was approved.
February 14, 2008
ITEM NO.. F.1 FILE NO.. Z -7500-D
NAME: Pinnacle Village Long -form PCD
LOCATION: Located North of Cantrell Road, West of Pinnacle Valley Road and North
of the Taylor Loop Road/Cantrell Road Intersection
DEVELOPER:
Rees Development Company
12115 Hinson Road
Little Rock, AR 72212
ENGINEER:
McGetrick and McGetrick Engineers
10 Otter Creek Court, Suite A
Little Rock, AR 72210
AREA: 24.37 Acres
CURRENT ZONING:
ALLOWED USES:
PROPOSED ZONING:
PROPOSED USE:
NUMBER OF LOTS: 1
PCD
FT. NEW STREET: 0
Commercial, Office/Warehouse
Revised PCD
Commercial
VARIANCES/WAIVERS REQUESTED: A variance from the Land Alteration Ordinance
to allow advanced grading of the site with the development of the first phase.
The applicant submitted a request dated December 5, 2007, requesting a deferral of the
item to the February 14, 2008, public hearing. Staff is supportive of the deferral
request.
PLANNING COMMISSION ACTION: (JANUARY 3, 2008)
Mr_ Pat McGetrick of McGetrick and McGetrick Engineers was present representing the
request. Staff presented the item stating the applicant had submitted a request dated
December 5, 2007, requesting a deferral of the item to the February 14, 2008, public
hearing. Staff stated they were supportive of the deferral request.
February 14, 2008
SUBDIVISION
ITEM NO.: F.1 Cont. FILE NO.: Z -7500-D
There was no further discussion of the item. The chair entertained a motion for
placement of the item on the Consent Agenda for Deferral. The motion carried by a
vote of 10 ayes, 0 noes and 1 absent.
STAFF UPDATE:
The applicant submitted a request dated January 29, 2008, requesting withdrawal of
this item. Staff is supportive of the withdrawal request.
PLANNING COMMISSION ACTION: (FEBRUARY 14, 2008)
The applicant was present. There were no registered objectors present. Staff
presented the item stating the applicant had submitted a request dated January 29,
2008, requesting withdrawal of this item. Staff stated they were supportive of the
withdrawal request.
There was no further discussion of the item. A motion was made to approve the item as
presented by staff on the consent agenda. The motion carried by a vote of 8 ayes,
0 noes and 3 absent.
2
ITEM NO.: 12.
NAME: Pinnacle Village Long -form PCD
Z -7500-D
LOCATION: located North of Cantrell Road, West of Pinnacle Valley Road and North of
the Taylor Loop Road/Cantrell Road Intersection
Planning Staff Comments:
1. Provide notification of property owners located within 200 feet of the site, complete
with the certified abstract list, notice form with affidavit executed and proof of
mailing. The notice must be mailed no later than December 19, 2007. The Office of
Planning and Development must receive the proof of notice no later than December
28, 2007.
2. Is advanced grading being requested as a part of the proposed development?
3. Provide details of the proposed uses and the proposed use mix of the development.
Provide a maximum square footage of commercial uses and a maximum square
footage of restaurant uses for the site.
4. Provide details of proposed screening to be located to the west, east and north of
the site including any proposed fencing, plantings and the treatment of the rears of
the proposed buildings.
5. Provide details of the proposed mechanical treatment such as location and proposed
screening.
6. The indicated site plan does not include and allow for pedestrian access through the
site. Provide detailed pedestrian walkways and pedestrian tables to allow safe
pedestrian access through the site.
7. Provide details of any proposed signage to be located within the development as
well as signage proposed adjacent to Highway 10. All signage located within the
development will need to be approved by the Commission as a part of the
application request. The indicated buildings do not have public street frontage which
typically does not allow signage.
8. The proposed dumpster facilities are located adjacent to the residentially zoned
property. Provide a note indicating the proposed screening of the dumpster
facilities. Will the hours of service be limited for the dumpster facilities?
9. The site plan indicates the placement of service bays adjacent to the residentially
zoned properties. Provide details of the proposed screening mechanism for these
service bays.
10. Provide details of the proposed retaining wall adjacent to the floodway including
height and construction materials.
11. Indicate on the site plan any areas where existing trees are to be retained.
12.Any additional site lighting must be low level and directional, directed inward away
from residentially zoned properties. Provide details of proposed site lighting to
ensure the Highway 10 Design Overlay District is protected with regard to
preservation of the scenic appearance of the corridor.
Item # 12.
13. The western and northern walls are located adjacent to residentially zoned property.
These walls have a large mass. Provide details of the proposed mechanism for
breaking of this massing.
14. During the site work, the required land use buffer and street buffer must be
preserved. Construction fencing must be in place to protect all required buffers prior
to the initiation of any site work.
15. Directional signage must comply with the City Zoning Ordinance unless otherwise
approved by the Planning Commission.
16. Provide a maximum building height in the general notes section of the proposed site
plan.
Variance/Waivers., None requested.
Public Works Conditions:
1. Provide traffic study for generation of traffic on the property and adequacy of
proposed main entrance. Indicate peak hour traffic figures for the high-intensity
commercial establishments that already exist or will exist along the main entrance
road. The study should also address the impact of possible future access from other
adjacent properties to the west.
2. The proposed access through a previously approved PCD to the south creates a
major commercial access street with nine driveways along the main entrance road.
The traffic study must show this potentially significant restriction to the free flow of
traffic into and out of the proposed development.
3. A grading permit in accordance with Section 29-186 (c) & (d) will be required prior to
any land clearing or grading activities at the site. Site grading, and drainage plans
will need to be submitted and approved prior to the start of construction.
4. Storm water detention ordinance applies to this property. Show the proposed
location for storm water detention facilities on the plan.
5. A special Grading permit for Flood Hazard Areas will be required per Section 8-283
prior to construction.
6. The minimum Finish Floor elevation of one (1) foot above the base flood elevation is
required to be shown on plat and grading plans.
7. If disturbed area is one (1) or more acres, obtain a NPDES storm water permit from
the Arkansas Department of Environmental Quality prior to the start of construction.
8. In accordance with Section 31-176, floodway areas must be shown as floodway
easements or be dedicated to the public. In addition, a 25 foot wide access
easement is required adjacent to the floodway boundary. If encroachment is desired
in the regulatory floodway, written approval should be obtained from FEMA prior to
the issuance of any city permits and the commencement of construction.
9. Hauling of fill material on or off site over municipal streets and roads requires
approval prior to a grading permit being issued. Contact Public Works Traffic
Engineering at 621 S. Broadway, (501) 379-1805 (Travis Herbner) for more
information.
10.The proposed western driveway should be constructed to a commercial standard
similar to the first 260 feet.
11. Alteration of the water course of Isom Creek will require approval from the Little
Rock District of the US Army Corps of Engineers prior to start of work.
Item # 12.
12. Per Section 29-190(15), a minimum strip 25 ft wide, undisturbed except for
reasonable access, shall be provided along each side of streams having a ten (10)
year storm of greater than one hundred fifty (150) cubic feet per second. The twenty
five (25) foot strip shall be measured from the top of the bank. Provide a sketch
grading and drainage plan showing detention area, creek centerline, proposed
contours and wooded areas, previously cleared areas, and limits of clearing.
13. Plans of all work in right-of-way shall be submitted for approval prior to start of work.
Obtain barricade permit prior to doing any work in the right-of-way from Traffic
Engineering at (501) 379-1805 (Travis Herbner).
14. Coordinate design of traffic signal upgrade with proposed street improvements.
Plans to be forwarded to Traffic Engineering for approval.
15. Erosion controls must be installed to reduce discharge of polluted storm water.
Utilities and Fire Department/County Planning:
Wastewater: Existing sewer mains on site. No construction allowed within
existing easement. Contact LRW for details.
Entergy: No comment received.
Center -Point Ener : No comment received.
AT & T: No comment received.
Central Arkansas Water: All Central Arkansas Water requirements in effect at the
time of request for water service must be met. Additional fire hydrant(s) will be required.
Contact the Little Rock Fire Department to obtain information regarding the required
placement of the hydrant(s) and contact Central Arkansas Water regarding procedures
for installation of the hydrant(s). The facilities on-site will be private. When meters are
planned off private lines, private facilities shall be installed to Central Arkansas Water's
material and construction specifications and installation will be inspected by an
engineer, licensed to practice in the State of Arkansas. Execution of Customer Owned
Line Agreement is required. A Capital Investment Charge based on the size of
connection(s) will apply to this project in addition to normal charges. This fee will apply
to all connections including metered connections off the private fire system. Protection
of the raw water limes that cross this property will be of utmost importance in planning
and constructing this project. Coordinate carefully with Central Arkansas Water. This
development will have minor impact on the existing water distribution system. Proposed
water facilities will be sized to provide adequate pressure and fire protection.
Fire Department: Place fire hydrants per code. Contact Little Rock Fire Department
for more information.
County Planning: No comment.
CATA: The site is located on CATA Bus Route #25, the Highway 10 Express
Route.
Item # 12.
Parks and Recreation: Please provide an easement for future tail access along the
rear of the site.
Planning Division: This request is located in the River Mountain Planning District. The
Land Use Plan shows Transition and Single Family. The applicant has applied for a
Long Form PCD to allow the rezoning for a commercial center with C-3 retail space.
A Land Use Plan Amendment is a separate item on this agenda.
Master Street Plan: Cantrell Road is shown as a Principal Arterial. The primary
function of a Principal Arterial is to serve through traffic and to connect major traffic
generators or activity centers within urbanized areas. Entrances and exits should be
limited to minimize negative effects of traffic and pedestrians on Cantrell since it is a
Principal Arterial. This street may require dedication of right-of-way and may require
street improvements for entrances and exits to the site.
Bicycle Plan: There are no bike routes shown in the immediate vicinity.
Neighborhood Action Plan: This area is covered by the River Mountain Neighborhood
Action Plan, but the plan does not address this issue.
Landscape:
1. The site plan must comply with the City's minimum landscape and buffer ordinance
requirements.
2. This development is located within the Arkansas Highway 10 Overlay District;
therefore, must comply with the standards put forth in addition to the landscape and
buffer ordinance requirements.
3. It appears that changes to the phase one of the site plan have been made. A
parking lot is shown behind one of the existing buildings and it is located within the
Highway 10 Overlay District, twenty-five foot (25') wide strip. This modification is not
allowed and must be changed by its elimination from the site plan.
4. This project was reviewed as a unitary development.
5. Berming is encouraged along Arkansas Highway 10.
6. Interior islands must be a minimum of three hundred (300) square foot in area to
qualify towards the minimum landscape ordinance requirements.
7. The area along the eastern and western property lines is zoned residential;
therefore, a land use buffer of fifty foot (50') is required. Seventy (70%) percent of
this are is to remain undisturbed.
8. The area along the northern property line is zoned residential, therefore, a land use
buffer of forty-three foot (43') is required. Seventy (70%) percent of this area is to
remain undisturbed.
9. The AR Highway 10 Overlay requires a twenty-five foot (25') wide landscape strip
around the sites entirety; minus adjoining properties of the same ownership. In this
instance the minimum amount shall be nine foot (9').
10. The property to the east, west, and north is zoned residential, therefore, a six (6) foot
high opaque screen, either a wooden fence with its face side directed outward, a
wall, or dense evergreen plantings, is required along the eastern perimeter of the
site.
Item # 12.
11. An automatic irrigation system to water landscaped areas will be required.
12. Prior to the issuance of a building permit, it will be necessary to provide an approved
landscape plan stamped with the seal of a Registered Landscape Architect.
13.The City Beautiful Commission recommends preserving as many existing trees as
feasible on this tree covered site. Credit toward fulfilling Landscape Ordinance
requirements can be given when preserving trees of six (6) inch caliper or larger.
Revised plat/plan: Submit four (4) copies of a revised preliminary plat/plan (to include
the additional information as noted above) to staff on Wednesday, December 5, 2007.
Item # 12.