HomeMy WebLinkAboutResponse to Comments 2 090823Z-9836 Freeman STR-2—PD-C 14515 Jerome Drive
Jc �J 0" Gk Kc
One orTwo-Family Residential Developments, g�N-5
L
A Appendix D, Section D107.1 of the Arkansas--PreventionaVol. 1, One -or Two-Famlly
dwelling residential developments. Developments of one- or two-family dwellings where the number of
dwelling units exceeds 30 shall be provided with two separate and approved fire apparatus access
roads, and shall meet the requirements of Section D104.3.
Exceptions:
1. Where there are more than 30 dwelling ants on a single public or private fire apparatus
access road and al dwelling units are equipped throughout with an approved automatic
sprinkler system in accordance with Section 903.3.1.1, 903.3.1.2 or 903.3.1.3 of the
Arkansas Fire Code, access from two directions shall not be required.
2. The number of dwelling units on a single fire apparatus access road shall not be increased
unless fire apparatus access roads will connect with future development, as determined by
the fire code official.
Fire Hydrants
Locate Fire Hydrants as per Appendix C of the 2021 Arkansas Fire Prevention Code. Section C301-
C305, in conjunction with Central Arkansas Water (Daniel Tull 501-377-1245) and the Little Rock Fire
Marshals Office (Capt. Tony Rhodes 501-918-3757, or Fire Marshal Derek N Ingram 501-918-3756
Number and Distribution of Fire Hydrants as per Table C305.1.
Z-9837 Bole STR-2 — PD-C 2008 North Harrison Street
One or Two Family Residential Developments._
As per Appendix D, section D107.1 of the Arkansas Fire Prevention Code Vol. 1, One- or T—Family
dwelling residential developments. Developments of one -or two-family dwellings where the number of
dwelling units exceeds 30 shall be provided with two separate and approved fire apparatus access
roads, and shall meet the requirements of Section D104.3.
Exceptions:
1. Where there are more than 30 dwelling units on a single public or private fire apparatus
access road and al dwelling units are equipped throughout with an approved automatic
sprinkler system in accordance with Section 903.3.1.1, 9033.1.2 or 903.3.1.3 of the
Arkansas Fire Code, access from two directions shall not be required.