HomeMy WebLinkAboutZ-7466 Staff AnalysisAugust 25, 2003 M NO.: 1 File No.: Z-7466 Owner: Arkansas Blue Cross and Blue Shield Address: Northwest corner of West 7th and Gaines Streets Description: Lots 5-8 and part of Lots 4 and 9, Block 177, Original City of Little Rock Zoned: UU Variance Requested: A variance is requested from the height provisions of Section 36-342.1 to allow construction of a parking deck which exceeds the maximum height allowed. Justification: The applicant's justification is presented in an attached letter. Present Use of Property: Surface parking lot Proposed Use of Property: Parking Deck STAFF REPORT A. Public Works Issues: 1. Repair or replace any curb and gutter or sidewalk that is damaged in the public right-of-way prior to occupancy. Some handicap ramps do not meet current ADA standards and may need to be replaced. B. Landscape and Buffer Issues: Landscaping is required to be in conformance with Urban Use District standards. These standards include minimum three (3) inch caliper trees thirty (30) feet on center around the perimeter of the site. Trees should not be closer than thirty (30) feet to street intersections. August 25, 2003 Item No.: 19 (Cont. C. Staff Analysis: The UU zoned property at the northwest corner of West 7th and Gaines Streets is occupied by a paved surface parking lot. The parking lot serves the Arkansas Blue Cross and Blue Shield office building which is located across Gaines Street to the east. The parking lot is enclosed with an ornamental iron fence. There is a driveway from Gaines Street which serves as access. The parking lot occupies the entire block bounded by Gaines Street, State Street, West 7th Street and West 6th Street. The applicant proposes to construct a multi-level parking deck within the south one-half of this block. The parking deck will serve the Arkansas Blue Cross and Blue Shield building, providing secure, covered parking for employees. The proposed parking deck will have a skywalk over Gaines Street, connecting the deck to the Blue Cross office building. The proposed parking deck main structure will have a height of approximately 77 feet, with the elevator tower portion of the structure having a height of approximately 95 feet. The applicant has noted that the parking deck could have as many as seven (7) levels. Section 36- 342.1(e) of the City's Zoning Ordinance allows a maximum height of five (5) stories or 75 feet in the UU Zoning District. Therefore, the applicant is requesting a variance from this ordinance standard. To staff s knowledge, this is the only variance needed from the Zoning Ordinance for the proposed deck construction. Staff is supportive of the variance request. The proposed building height will not be out -of -character with other buildings in this general area. The Federal Building, Federal Courts Building and the Legacy Hotel all have building heights of five (5) stories or higher. Additionally, the Blue Cross building has a height equivalent to 12 stories. The proposed parking deck will provide additional needed parking for this area, and should have no adverse impact on the surrounding properties. if approved, the proposed skywalk over Gaines Street will have to be reviewed and approved by the City's Board of Directors. D. Staff Recommendations: Staff recommends approval of the proposed height variance, subject to the following conditions: 1. Compliance with the requirements as noted in paragraphs A and B of this report. 2 August 25, 2003 No.: 19 (Cont. 2. The proposed skywalk structure must be approved by the Board of Directors. 3. The proposed structure must comply with all other UU Zoning District development standards. BOARD OF ADJUSTMENT: (AUGUST 25, 2003) The applicant was present. There were no objectors present. Staff presented the item and a recommendation of approval. The applicant offered no additional comments. The item was placed on the Consent Agenda and approved as recommended by staff by a vote of 4 ayes, 0 nays and 1 absent. 3