Loading...
HomeMy WebLinkAboutZ-7456 Map 94' cama V/ 6'X6' -L4 V X IA V VVF LAPACTm E TFeL IY%Tf�MORER R VKL tl D TR M W&E WALL V/ K MRS Wa a IW VERTIVLLY MP LEN61H S1MLL K 7 N MILUm N IFWTIM INTO TIE EXISTIW WALL le, K[ a MRs a w E FADE SECTI❑N @ END OF RETAINING WALL SCALE: 3/8'=1' 4' CONC. SLAB W/ 6'X6' -1.4 W X 1.4 W WWF EXISTING RETAINING WALL TO REMAIN 6' GRAVEL 05 @ 18' TOP 6 BOTTOM EA. WAY e 12'X24' REINFORCED CONCRETE BLOCK PILASTER COMPACTED SELECT FILL WOOD FENCE 12' X 24' REINFORCED CONCRETE BLOCK PILASTER 8' BOND BEAM W/ •6 BAR CONTINUOUS 8' CONE. BLOCK WALL W/ 12' X 24' _/ REINFORCED CONCRETE BLOCK PILASTER NOTE, VERTICAL CONTROL JOINT @ 20' O.C. (HORIZONTAL REINFORCEMENT TO BE CONTINUOUS THROUGH CONTROL JOINTS) I A 12' REINFORCED CONCRETE BLOCK RETAINING WALL FILLED V/ CONCRETE 45 @ 8' D.C. EACH FACE NOTES AT PILASTER LOCATIONS REINF. IS 6-06(3 EA. FACE) CONT. TOP OF WALL TO BOTTOM OF WALL. 5 @ 8' DOWELS ACE FACE *BOTTOM OF FOOTING TO BEAR ON UNDISTURBED SOIL. SECTI❑N @ WALL - STA 0+72.89 TO 0+96.31 SCALE 3/8'=1' CONCRETE AND FOUNDATION NOTE 1, THE PAVEMENT SLAB SHALL BEAR ON A MINIMUM OF 4' OF SAND OR GRAVEL. A 6 MIL VISQUEEN TYPE VAPOR BARRIER SHALL BE PLACED DIRECTLY BENEATH THE SLAB, 2 BENEATH THE GRAVEL OR SAND SHALL BE COMPACTED SELECT LOW PLASTICITY FILL. SELECT FILL SHALL BE PLACED IN 6-8 INCH LOOSE LIFTS AND COMPACTED TO AT LEAST 95% OF THE MAXIMUM DRY DENSITY AS DETERMINED BY STANDARD PROCTOR (ASTM D-698) PROCEDURE. 3. SELECT FILL SOILS SHALL CONSIST OF CLAYEY SAND, SANDY CLAY, OR CLAYEY GRAVEL HAVING A LIQUID LIMIT LESS THAN 40. 4. THE FOUNDATION DESIGN IS BASED ON AN ALLOWABLE BEARING PRESSURE OF 2000 PSF. CONTRACTOR SHALL RETAIN A GEOTECHNICAL TESTING FIRM TO CONFIRM THAT THE CAPABILITY OF EXISTING SOILS HAVE THIS CAPABILITY. ALL FOOTINGS SHALL BE PLACED ON UNDISTURBED SOIL. 5. AMERICAN CONCRETE INSTITUTE (ACI) SPECIFICATIONS SHALL GOVERN ALL PHASES OF CONCRETE CONSTRUCTION. 6. ALL CONCRETE SHALL HAVE A 28 DAY COMPRESSIVE STRENGTH OF 3000 PSI. 7. ALL REINFORCING STEEL SHALL BE GRADE 60. REINFORCED MASONRY NOTES 1. MASONRY SHALL MEET THE REQUIREMENTS OF THE SPECIFICATION FOR MASONRY STRUCTURES, ACI 530-99. 2. COMPRESSIVE STRENGTH FOR MASONRY (f'n) SHALL BE 1500 PSI. 3. CONCRETE BLOCK TO BE FILLED WITH CONCRETE AND REINFORCED SHALL BE AS SHOWN ON THE PLANS, VERTICAL REINFORCING MAY BE SPLICED IF REQUIRED. MINIMUM LAP SPLICES SHALL BE 48 BAR DIAMETERS. 4. CENTRAL JOINTS FOR THE 8' CONCRETE BLOCK WALL SMALL BE LOCATED @ MIDPOINT BETWEEN PILASTER AND SHALL NOT EXCEED 24' SPACING. 5, HORIZONTAL REINFORCING SHALL BE WITH DURAWALL, OR EQUAL, SPACED EVERY OTHER BLOCK BLOCK COURSE, 6. BOND BEAMS SHALL BE FILLED WITH 3000 PSI CONCRETE. 7. ALL CONCRETE BLOCK SHALL BE LAID AT RUNNING BOND AND INTER GRADED WITH THE PILASTER. 8, PILASTER REINFORCING SMALL BE CONTINUOUS FROM TIP OF WALL TO BOTTOM OF RETAINING WALL, I HEREBY CERTIFY THAT THE FOUNDATION SHOWN ON THE DRAWING MEETS THE SEISMIC STRUCTURAL DESIGN REQUIREMENTS OF THE 2000 INTERNATIONAL BUILDING CODE. 4' CONC. SLAB W/ 6'X6' -L4 V X 1.4 W WWF _______-.------------------ JAMES C. Sl1MMERLIN, P.E. REGISTERED PROFESSIONAL ENGINEER NO. 2699 12' X 24' REINFORCED CONCRETE BLOCK PILASTER EXISTING 15' RCP 0 DETERMINED IN FIELD WOOD FENCE 8' CONC. BLOCK WALL W/ 12' X 24' _----REINFORCED CONCRETE BLOCK PILASTER NOTE. VERTICAL CONTROL JOINT @ 20' O.C. (HORIZONTAL REINFORCMENT TO BE CONSTRUCTED THROUGH CENTRAL JOINTS) 12' REINFORCED CONC. BLOCK SECTI❑N @ WALL - STA 0+6450 TO 0+72.89 SCALE, 3/8'=1' 12' X 24' REINFORCED CONG. BLOCK PILASTER W/ 6-p6 BARS r CONT. TOP TO BOTTOM '(TYPJ i 8' BOND BEAM W/ ' k6 BAR CONT. THROUGH PILASTER SECTION B SCALD 3/8'=1' 12'X24' REINFORCED CONCRETE BLOCK 8' CONC. BLOCK WALL PILASTER \ (RUNNING BOND ❑ � f + �/ THROUGH PILASTER) SECTI❑N A SCALE; 3/8'=1' 9 12' X 24' REINFORCED CONCRETE BLOCK PILASTER NOTE, SLAB NOT PRESENT UNTIL STA 0+50 `74, + NNS BARS @ 24. O.C. BOTTOM OF FOOTING TO BE-T— E LOCATED @ ELEV. OF EXISTING R.C.P. —TO BE TO BEAR ON UNDISTURBED SOIL) DETERMINED IN FIELD JAIiY,1� 5 n !: ii/• Uj e \ i FS 19MIMMt7 ff"1111 SPLICE 8' CONC. BLOCK WALL W/ 12' X 24' _-/ REINFORCED CONCRETE BLOCK PILASTER NOTE VERTICAL CONTROL JOINT @ 20' O.C. (HORIZONTAL REINFORCMENT TO BE CONSTRUCTED THROUGH CENTRAL JOINTS) TO'BE DETERMINED IN FIELD SECTI❑N @ WALL (SIMILAR) - STA 0+05.00 TO 0+64.50 SCALE, 3/8'=1' •.bird b to 6e claoned and MW with hot joint soler ffmWrW. Gdl with SEN.ER COMPOUND ., ..'. 41/4. vvvvvv0000vovvvvvvvvv • v v aC�{ed glary BoFa v v v v v v ee............ aovavo Geot4XWe Fabic CONTRACTION JOINT Compacted Sabgrade HOT TO SCAM (SCJ - SAW CUT JOINT) Q� -1/2' MM. TOP 1'HOT JOINT 3/4' EXPANSION JONSEALER +-/8018'-24' LONG MATERIAL EXPANSION y CRUSHED STONE JbMf MATETBAL (COMPACTED) GeotaX6le Fabric Compacted SttJ7rode LONGITUDINAL (CONSTRUCTION JOINT) NOT TO SCALE TOP 1', HOT JOINT SEALER COMPOUND 3/4' EXPANSION JOINT MATERIAL /6-24- DOWEL O 18'C.0 SOAK WITH MC -2 Metd sle �CON(.R•E7E'M . r4. .. ._ EXPANSION JOINT NOT TO SCALE Ile Fnt H Sabgmd•