Loading...
HomeMy WebLinkAboutZ-7456 Map 64• co N[. SLAP W/ 4'%6• -1.4 W % L4 W V VF IV REINi1Rfl0 COC. -��BLOCX Vitt 14T'EJ TIC TO C%ISTDG WALL V/ K PMS SPAR➢ a IP' VERIIf y PM LEN SNLLL K T -V Am WMeati ie•AOEwwrEo 11410 TIE OOSTIM (X PA m KI ECT FILL a5 PMif a M mc. CALX FMS EST 0 0�00- 000 00 00000000 0 SECTION @ END OF RETAINING WALL SCALE: 3/8'=1' 12'X24' REINFORCED CONCRETE BLOCK PILASTER 4' CONC. SLAB W/ 6'X6' -1.4 W X 1.4 W WWF COMPACTED SELECT FILL EXISTING RETAINING WALL TO REMAIN 6' GRAVEL s� WOOD FENCE 12' X 24' REINFORCED CONCRETE BLOCK PILASTER 8' BOND BEAM W/ i6 BAR CONTINUOUS 8' CONC. BLOCK WALL V/ 12' X 24' _/REINFORCED CONCRETE BLOCK PILASTER NOTE. VERTICAL CONTROL JOINT a 20' O.C. (HORIZONTAL REINFORCEMENT TO BE CONTINUOUS THROUGH CONTROL JOINTS) I A 12' REINFORCED CONCRETE BL13CK RETAINING WALL FILLED W/ CONCRETE 115 a 8' O.C. EACH FACE NOTE- AT PILASTER LOCATDONS REINF. IS 6-860 EA. FACE) CUNT, TEP OF WALL TO BOTTOM OF WALL, L,. �,....-.,.. ;-.. 115 a e' DOWELS 85 @ 18' TOP 6 - FACE FACE BOTTOM EA. WAY .: l-6' ��.._ wBOTTOM OF FOOTING TO BEAR ON UNDISTURBED SOIL. SECTI❑N @ WALL — STA 0+72.89 TO 0+96.31 SCALE: 3/8'=1' 4' P -1.4 CONCRETE AND FOUNDATION NOTE, 1. THE PAVEMENT SLAB SHALL BEAR ON A MINIMUM OF 4' OF SAND OR GRAVEL. A 6 MIL VISQUEEN TYPE VAPOR BARRIER SHALL BE PLACED DIRECTLY BENEATH THE SLAB, 2 BENEATH THE GRAVEL OR SAND SHALL BE COMPACTED SELECT LOW PLASTICITY FILL. SELECT FILL SHALL BE PLACED IN 6-8 INCH LOOSE LIFTS AND COMPACTED TO AT LEAST 95% OF THE MAXIMUM DRY DENSITY AS DETERMINED BY STANDARD PROCTOR (ASTM D-698) PROCEDURE. 3. SELECT FILL SOILS SHALL CONSIST OF CLAYEY SAND, SANDY CLAY, OR CLAYEY GRAVEL HAVING A LIQUID LIMIT LESS THAN 40, 4. THE FOUNDATION DESIGN IS BASED ON AN ALLOWABLE BEARING PRESSURE OF 2000 PSF. CONTRACTOR SMALL RETAIN A GEOTECHNICAL TESTING FIRM TO CONFIRM THAT THE CAPABILITY OF EXISTING SOILS HAVE THIS CAPABILITY. ALL FOOTINGS SHALL BE PLACED ON UNDISTURBED SOIL. 5. AMERICAN CONCRETE INSTITUTE (ACI) SPECIFICATIONS SHALL GOVERN ALL PHASES OF CONCRETE CONSTRUCTION. 6. ALL CONCRETE SHALL HAVE A 28 DAY COMPRESSIVE STRENGTH OF 3000 PSI. 7. ALL REINFORCING STEEL SHALL BE GRADE 60. REINFORCED MASONRY NOTES - 1. MASONRY SHALL MEET THE REQUIREMENTS 13F THE SPECIFICATION FOR MASONRY STRUCTURES, ACI 530-99, 2. COMPRESSIVE STRENGTH FOR MASONRY (f'm) SHALL BE 1500 PSI. 3. CONCRETE BLOCK TO BE FILLED WITH CONCRETE AND REINFORCED SHALL BE AS SHOWN IXJ THE PLANS. VERTICAL REINFORCING MAY BE SPLICED IF REQUIRED. MINIMUM LAP SPLICES SHALL BE 48 BAR DIAMETERS. 4. CENTRAL JOINTS FOR THE 8' CONCRETE BLOCK WALL SHALL BE LOCATED a MIDPOINT BETWEEN PILASTER AND SHALL NOT EXCEED 24' SPACING. 5. HORIZONTAL REINFORCING SHALL BE VITH DURAWALL, OR EQUAL, SPACED EVERY OTHER BLOCK BLOCK COURSE, 6. BOND BEAMS SHALL BE FILLED WITH 3000 PSI CONCRETE. 7. ALL CONCRETE BLOCK SHALL BE LAID AT RUNNING BOND AND INTER GRADED WITH THE PILASTER. 8. PILASTER REINFORCING SHALL BE CONTINUOUS FROM TOP OF WALL TO BOTTOM OF RETAINING WALL. I HEREBY CERTIFY THAT THE FOUNDATION SHOWN ON THE DRAWING MEETS THE SEISMIC STRUCTURAL DESIGN REQUIREMENTS OF THE 2000 INTERNATIONAL BUILDING CODE. DATED:--------------- ----------------------_---- JAMES C. SUMMERLIN, P.E. REGISTERED PROFESSIONAL ENGINEER NO. 2699 DETERMINED IN FIELD V011111yy:I9M 8' CONC. BLOCK WALL W/ 12' X 24' REINFORCED CONCRETE BLOCK PILASTER NOTE, VERTICAL CONTROL JOINT a 20' O.C. (HORIZONTAL REINFORCMENT TO BE CONSTRUCTED THROUGH CENTRAL JOINTS) 12' REINFORCED CONC. BLOCK SECTION @ WALL — STA 0+64.50 TO 0+72,89 SCALE: 3/8'=1' 12' X 24' REINFORCED CONC. BLOCK PILASTER W/ 6-86 BARS CONT. TOP TO BOTTOM d - '(TYPJ 8' BOND BEAM W/ 86 BAR CONT. THROUGH PILASTER SECTI❑N B SCALE: 3/8'=1' 12'X24' REINFORCED CONCRETE BLOCK 8' CONC. BLOCK WALL PILASTER \ (RUNNING BOND / THROUGH PILASTER) 00`:x❑ SECTI❑N A SCALE 3/8'=1' I. 12' X 24' REINFORCED CONCRETE BLOCK PILASTER WOOD FENCE SPLICE 8' CONC. BLOCK WALL W/ 12' X 24' _----REINFDRCED CONCRETE BLOCK PILASTER NOTE: VERTICAL CONTROL JOINT a 20' D.C. (HORIZONTAL REINFORCMENT TO BE CONSTRUCTED THROUGH CENTRAL JOINTS) A NOTE• SLAB NOT PRESENT UNTIL STA 0+50 + I B5 BARS CONTINUOUS -47 85 BARS :._ l• TO BE DETERMINED e 24' OC 4. • i; I IN FIELD BOTTOM OF FOOTING TO BE LOCATED a ELEV. OF EXISTING R.C.P, TO BE (FOOTING TO BEAR ON UNDISTURBED SOIL) DETERMINED I EXISTING7 N FIELD 15' RCP SECTI❑N @ WALL (SIMILAR) = STA_ 0+05.00 T❑ 0+64.50 SCALE: 3/8'=1' TOP I''HOT JOINT SELLCOMPOUND MPOUND •iairt M to Ib clwned mW fitled with hot joint eeNer mvterial. 3/4' EXPANSION JOINT MATERIAL 06-24' DOWEL O /8'C.0 VfM Sill wi COMPOUND -1/2' MM. SOAK WITH MC -2 3/4' EXPANSION JOINT MATERIAL TW 1•J HOT ,OND YstPl 56esva SEALER COMPOUND 1-1 2 .I Y ♦'.CONCRETE' ... . I ' �16'-24' CON(: 7' Y •� -+1. {}-1/4 y. CRUSHED SIONE 3 I• MATERIAL A .. ETE IOOMPACTID) vvvvvevvv vvv a vvvvvvvv `�• avavoeevevevvvavvavvv S• v v eCo,npoct4d Slon• Bva e v o v v 5' v v o Co:nWcteO Slone Bmea v v v v v e%01. Fabric Gaote%ble Fvbric CONTRACTION JOINT Em ported SRbgm& LONGITUDINAL (CONSTRUCTION JOINT) CorVw W SubPvde NOT TO SCALE NOT TO scN.E EXPANSION JOINT NOT TO SCALE (SCJ - SAW CUT JOINT) SITE DETAILS %I -ATE 0.,LOT 5 RIVERVIEW MANOR SUBDIVISION ARIA M," AS LITTLE ROCK, ARKANSAS 4 L Project umbo, Y � h 6 Scale: N.T.S. W.WELLIAM GRAHAM, JR. INC. ' No CONSULTING ENGINEERS 2003 014 FS C SUVADate: 08/18/03 LITTLE ROCK, ARKANSAS Approved by: Sheet Number Drawn by: JDW Chocked by: T.C.S. ROBERT B. GRAHAM P.E. 2 of 3