HomeMy WebLinkAboutZ-7351 Staff AnalysisFILE NO.: Z-7351
NAME: Miracle Land Company Short -form PCD
LOCATION: On the southwest corner of 1-430 and Stagecoach Road
DEVELOPER:
Miracle Development, Inc.
8001 Stagecoach Road
Little Rock, AR 72210
CAIr'_IAICGR-
Global Surveying Consultants, Inc.
15605 Alexander Road
Alexander, AR 72002
AREA: 3.321 Acres NUMBER OF LOTS: 3 FT. NEW STREET: 0
CURRENT ZONING
C-3, General Commercial
ALLOWED USES: General Retail
PROPOSED ZONING: PCD
PROPOSED USE
Mini -warehouse, carwash and C-3 uses
VARIAN CESNVAIVERS REQUESTED: The creation of a lot without public street
frontage (Lot 3) [Section 31-231].
A. PROPOSALIREQUEST:
The applicant proposes to subdivide this site into three commercial lots and to
rezone the site to PCD to allow for the development of the site with a carwash on
Lot 1, an unidentified C-3 use to be located on Lot 2 and a mini -warehouse
development on Lot 3 extending from the east.
The plat will require a variance from the Subdivision Ordinance [Section 31-231]
a lot without public street frontage. Lot 3 will be -served by a 30 -foot access
easement located on the lot lines of Lots 1 and 2.
FILE NO.: Z-7351 (Cont.
The applicant will revise the site plan when development becomes a reality on
Lots 2 and 3.
B. EXISTING CONDITIONS:
The site is a vacant tree covered site currently zoned C-3. The site adjoins the
flood plain/floodway to the south in an area zoned OS. There is a mini -storage
development located to the east of the site adjacent to 1-430. Other uses in the
area include a church located north of the site, a welding shop and a mixture of
auto related uses; ABC Salvage, a tire company, a used car lot.
C. NEIGHBORHOOD COMMENTS:
As of this writing, staff has not received any comment from area residents. The
Otter Creek Homeowners Association, the Crystal Valley Property Owners
Association and Southwest United for Progress Neighborhood Association, all
property owners located within 200 -feet of the site and all residents, who could
be identified, located within 300 -feet of the site were notified of the public
hearing.
D. ENGINEERING COMMENTS:
PUBLIC WORKS CONDITIONS:
1. Stagecoach Road is classified on the Master Street Plan as a principal
arterial. Dedication of right-of-way to 55 -feet from centerline at all locations
will be required. Provide a survey showing the centerline of Stagecoach
Road.
2. Sidewalks with appropriate handicap ramps are required in accordance with
Section 31-175 of the Little Rock Code and the Master Street Plan.
3. In accordance with Section 31-176, floodway areas must be shown as
floodway easements or be dedicated to the public. In addition, a 25 -foot
wide access easement is required adjacent to the floodway boundary.
4. Show limits of the floodplain on the site plan (floodway limits are already
shown).
5. A grading permit and development permit for special flood hazard area is
required prior to construction.
6. Driveway locations and widths do not meet the traffic access and circulation
requirements of Sections 30-43 and 31-210. The lots must share a single
driveway access centered on the property line. The width of driveway must
not exceed 36 -feet.
7. All driveways shall be concrete aprons per City Ordinance.
8. Stormwater detention ordinance applies to this property.
9. Obtain permits (barricade/street cut) for improvements within proposed or
existing right-of-way from Traffic Engineering and AHTD prior to
construction in the right-of-way.
7
FILE NO.: Z-7351
10. Prepare a letter of pending development addressing streetlights as required
by Section 31-403 of the Little Rock Code. All request should be forwarded
to Traffic Engineering.
E. UTILITIES AND FIRE DEPARTMENT/COUNTY PLANNING:
Wastewater: Sewer available, not adversely affected.
Entergy: Approved as submitted.
Center -Point Ener : No comment received.
SBC: Approved as submitted.
Central Arkansas Water: A water main extension will be required in order to
provide service to this property. The Little Rock Fire Department needs to
evaluate this site to determine whether additional public and/or private fire
hydrant(s) will be required. If additional fire hydrant(s) are required, they will
be installed at the Developer's expense. Particularly planning for water
service and Fire Department access to Lot 3 should be considered. This
development will have minor impact on existing water distribution system.
Proposed water facilities will be sized to provide adequate pressure and fire
protection.
Fire Department: Fire hydrants will be required. Contact the Little Rock Fire
Department at 918-3752 for additional details.
County Planning: No comment received.
CATA: No comment received.
F. ISSU ES/TEC H N ICAL/DESIGN :
Planning Division: This request is located in the Otter Creek Planning District.
The Land Use Plan shows Commercial for this property. The applicant has
applied for a PCD with C-3 uses for a mini -storage expansion from the
development to the east and a new carwash. The request is consistent with the
Land Use of Commercial.
City Recognized Neighborhood Action Plan: The applicant's property lies in
the area covered by the Otter Creek/Crystal Valley Neighborhood Action Plan.
The plan contains an objective that discourages construction of large, warehouse
type facilities, and those of large scale and/or high intensity uses, within the
"heart" of the planning area. This application is located outside the "heart" of the
study area as described by the Neighborhood Action Plan.
3
FILE NO.: Z-7351
Landscape Issues: A land use buffer with an average width of 16.8 feet is
required along the western perimeter of the site. Utility easements cannot count
toward fulfilling this requirement.
A six (6) foot high opaque screen, either a wooden fence with its face side
directed outward, a wall, or dense evergreen plantings, is required along the
western perimeter.
If this project is to be separate from the project to the east, then a minimum 6.7
foot wide landscape strip will be required the entire length of the eastern
perimeter. However, if a portion of the eastern perimeter is to abut the same
use, then that portion will be exempted from the perimeter landscaping
requirement.
An irrigation system to water landscaped areas will be required.
Prior to a building permit being issued, it will be necessary to provide approved
landscape plans stamped with the seal of a Registered Landscape Architect.
Buildina Codes: No comment.
G. SUBDIVISION COMMITTEE COMMENT: (January 16, 2003)
The applicant was present representing the application. Staff presented an
overview of the item to the Committee noting additions, which were needed on
the proposed site plan. Staff requested additional details on Lot 3 including
building location, setbacks and outdoor storage areas identified. Staff also
requested the limits of the floodplain and all utility easements be indicated on the
proposed site plan.
The applicant indicated only Lot 1 had immediate plans for development. He
stated the proposed mini -storage on Lot 3 was not in the near future and when
the plan was developed he would return to the Commission and the Board for
approval of the modified site plan.
Public Works comments were addressed. Staff stated although there were two
existing driveway apron locations, the applicant should remove the western -most
drive and place a shared drive between Lots 1 and 2 near the eastern -most
driveway apron. Staff stated they would not support the two driveway locations
due to their closeness.
Landscaping comments were addressed. Staff stated if the area to the east was
not included in the proposal then the applicant would be required to meet all
landscaping and landuse buffer requirements. Staff suggested the applicant
include the existing mini -storage site with the development plan to reduce the
buffer requirements.
C!
FILE NO.: Z-7351 Cont.
There was no further discussion. The Committee then forwarded the item to the
full Commission for final action.
H. ANALYSIS:
The applicant submitted a revised site plan to Staff addressing most of the issues
raised by Staff and the Subdivision Committee. The applicant has indicated no
development will take place on Lots 2 or 3 at the present time. He has indicated
any future development will require Planning Commission and Board of Directors
approval prior to construction.
In the interim, Lot 1 will development with a carwash. The applicant has included
on the site plan the dumpster location with required screening, the location of the
vacuums, drive through and self -wash bays. The applicant has also indicated a
6.67 -foot landscape strip located on the east property line and the south property
line of Lot 1.
The proposed preliminary plat will require variance from the Subdivision
Ordinance [Section 31-231] the creation of a lot without public street frontage.
The applicant has indicated the lot will be served by a 30 -foot access and utility
easement located on the shared property lines of Lots 1 and 2. Staff is
supportive of the requested variance to allow the creation of a lot without public
street frontage and feels the proposed access is sufficient to access Lot 3 should
the lot develop as a separate parcel from the mini -warehouse to the east.
Staff is supportive of the development plan. Staff feels the applicant submitting a
site plan for each of the remaining lots, as development is proposed, is a very
desirable alternative. Otherwise, to Staff's knowledge there are no outstanding
issues associated with the proposed site plan.
STAFF RECOMMENDATION:
Staff recommends approval of the proposed development subject to compliance
with conditions outlined in paragraphs D, E and F of this report.
Staff recommends approval of the requested preliminary plat and the requested
variance from the Subdivision Ordinance to allow the creation of a lot without
public street frontage [Section 31-231].
PLANNING COMMISSION ACTION: (FEBRUARY 6, 2003)
The applicant was present. There were no objectors present. Staff presented the item
with a recommendation of approval of the proposed rezoning to PCD subject to
compliance with conditions outlined in paragraphs D, E and F of the above report.
9
FILE NO.: Z-7351
Staff stated the proposed development would result in the creation of a three (3) lot plat
which would require a variance to the Subdivision Ordinance. Staff presented a
recommendation of approval of the requested preliminary plat and the requested
variance from the Subdivision Ordinance to allow the creation of a lot without public
street frontage [Section 31-231 ].
There was no further discussion of the item. The item was placed on the Consent
Agenda for approval. The motion carried by a vote of 10 ayes, 0 noes and 1 absent.
0
February 6, 2003
ITEM NO.: 16
NAME: Miracle Land Company Short -form PCD
LOCATION: On the southwest corner of 1-430 and Stagecoach Road
FILE NO.: Z-7351
DEVELOPER: ENGINEER:
Miracle Development, Inc. Global Surveying Consultants, Inc.
8001 Stagecoach Road 15605 Alexander Road
Little Rock, AR 72210 Alexander, AR 72002
AREA: 3.321 Acres NUMBER OF LOTS: 3 FT. NEW STREET: 0
CURRENT ZONING- C-3, General Commercial
ALLOWED USES: General Retail
PROPOSED ZONING: PCD
PROPOSED USE: Mini -warehouse, carwash and C-3 uses
VARIANCESIWAIVERS REQUESTED: The creation of a lot without public street
frontage (Lot 3) [Section 31-231].
A. PROPOSAUREQUEST:
The applicant proposes to subdivide this site into three commercial lots and to
rezone the site to PCD to allow for the development of the site with a carwash on
Lot 1, an unidentified C-3 use to be located on Lot 2 and a mini -warehouse
development on Lot 3 extending from the east.
The plat will require a variance from the Subdivision Ordinance [Section 31-231]
a lot without public street frontage. Lot 3 will be served by a 30 -foot access
easement located on the lot lines of Lots 1 and 2.
February 6, 2003
SUBDIVISION
ITEM NO.: 16 Cont. FILE NO.: Z-7351
The applicant will revise the site plan when development becomes a reality on
Lots 2 and 3.
B. EXISTING CONDITIONS*
The site is a vacant tree covered site currently zoned C-3. The site adjoins the
flood plain/floodway to the south in an area zoned OS. There is a mini -storage
development located to the east of the site adjacent to 1-430. Other uses in the
area include a church located north of the site, a welding shop and a mixture of
auto related uses; ABC Salvage, a tire company, a used car lot.
C. NEIGHBORHOOD COMMENTS:
As of this writing, staff has not received any comment from area residents. The
Otter Creek Homeowners Association, the Crystal Valley Property Owners
Association and Southwest United for Progress Neighborhood Association, all
property owners located within 200 -feet of the site and all residents, who could
be identified, located within 300 -feet of the site were notified of the public
hearing.
D. ENGINEERING COMMENTS:
PUBLIC WORKS CONDITIONS:
1. Stagecoach Road is classified on the Master Street Plan as a principal
arterial. Dedication of right-of-way to 55 -feet from centerline at all locations
will be required. Provide a survey showing the centerline of Stagecoach
Road.
2. Sidewalks with appropriate handicap ramps are required in accordance with
Section 31-175 of the Little Rock Code and the Master Street Plan.
3. In accordance with Section 31-176, floodway areas must be shown as
floodway easements or be dedicated to the public. In addition, a 25 -foot
wide access easement is required adjacent to the floodway boundary.
4. Show limits of the floodplain on the site plan (floodway limits are already
shown).
5. A grading permit and development permit for special flood hazard area is
required prior to construction.
6. Driveway locations and widths do not meet the traffic access and circulation
requirements of Sections 30-43 and 31-210. The lots must share a single
driveway access centered on the property line. The width of driveway must
not exceed 36 -feet.
7. All driveways shall be concrete aprons per City Ordinance.
8. Stormwater detention ordinance applies to this property.
2
February 6, 2003
SUBDIVISION
ITEM NO.: 16 Cont. FILE NO.: Z-7351
9. Obtain permits (barricade/street cut) for improvements within proposed or
existing right-of-way from Traffic Engineering and AHTD prior to
construction in the right-of-way.
10. Prepare a letter of pending development addressing streetlights as required
by Section 31-403 of the Little Rock Code. All request should be forwarded
to Traffic Engineering.
E. UTILITIES AND FIRE DEPARTMENT/COUNTY PLANNING:
Wastewater: Sewer available, not adversely affected.
Entergy: Approved as submitted.
Center -Point Ener No comment received.
SBC: Approved as submitted.
Central Arkansas Water: A water main extension will be required in order to
provide service to this property. The Little Rock Fire Department needs to
evaluate this site to determine whether additional public and/or private fire
hydrant(s) will be required. If additional fire hydrant(s) are required, they will
be installed at the Developer's expense. Particularly planning for water
service and Fire Department access to Lot 3 should be considered. This
development will have minor impact on existing water distribution system.
Proposed water facilities will be sized to provide adequate pressure and fire
protection.
Fire Department: Fire hydrants will be required. Contact the Little Rock Fire
Department at 918-3752 for additional details.
County Planning: No comment received.
CATH: No comment received.
F. ISSUES/TECH N ICAL/DESIG N:
Planning Division: This request is located in the Otter Creek Planning District.
The Land Use Plan shows Commercial for this property. The applicant has
applied for a PCD with C-3 uses for a mini -storage expansion from the
development to the east and a new carwash. The request is consistent with the
Land Use of Commercial.
City Recognized Nei hborhood Action Plan: The applicant's property lies in
the area covered by the Otter Creek/Crystal Valley Neighborhood Action Plan.
The plan contains an objective that discourages construction of large, warehouse
3
February 6, 2003
SUBDIVISION
ITEM NO.: 16 Cont. FILE NO.: Z-7351
type facilities, and those of large scale and/or high intensity uses; within the
"heart" of the planning area. This application is located outside the "heart" of the
study area as described by the Neighborhood Action Plan.
Landscape Issues: A land use buffer with an average width of 16.8 feet is
'required along the western perimeter of the site. Utility easements cannot count
toward fulfilling this requirement.
A six (6) foot high opaque screen, either a wooden fence with its face side
directed outward, a wall, or dense evergreen plantings, is required along the
western perimeter.
If this project is to be separate from the project to the east, then a minimum 6.7
foot wide landscape strip will be required the entire length of the eastern
perimeter. However, if a portion of the eastern perimeter is to abut -the same
use, then that portion will be exempted from the perimeter landscaping
requirement.
An irrigation system to water landscaped areas will be required.
Prior to a building permit being issued, it will be necessary to provide approved
landscape plans stamped with the seal of a Registered Landscape Architect.
Buildin Codes: No comment.
G. SUBDIVISION COMMITTEE COMMENT: (January 16, 2003)
The applicant was present representing the application. Staff presented an
overview of the item to the Committee noting additions, which were needed on
the proposed site plan. Staff requested additional details on Lot 3 including
building location, setbacks and outdoor storage areas identified. Staff also
requested the limits of the floodplain and all utility easements be indicated on the
proposed site plan.
The applicant indicated only Lot 1 had immediate plans for development. He
stated the proposed mini -storage on Lot 3 was not in the near future and when
the plan was developed he would return to the Commission and the Board for
approval of the modified site plan.
Public Works comments were addressed. Staff stated although there were two
existing driveway apron locations, the applicant should remove the western -most
drive and place a shared drive between Lots 1 and 2 near the eastern -most
driveway apron. Staff stated they would not support the two driveway locations
due to their closeness.
it
February 6, 2003
SUBDIVISION
ITEM NO.: 16 (Cont.
FILE NO_: Z-7351
Landscaping comments were addressed. Staff stated if the area to the east was
not included in the proposal then the applicant would be required to meet all
landscaping and landuse buffer requirements. Staff suggested the applicant
include the existing mini -storage site with the development plan to reduce the
buffer requirements.
There was no further discussion. The Committee then forwarded the item to the
full Commission for final action.
H. ANALYSIS:
The applicant submitted a revised site plan to Staff addressing most of the issues
raised by Staff and the Subdivision Committee. The applicant has indicated no
development will take place on Lots 2 or 3 at the present time. He has indicated
any future development will require Planning Commission and Board of Directors
approval prior to construction.
In the interim, Lot 1 will development with a carwash. The applicant has included
on the site plan the dumpster location with required screening, the location of the
vacuums, drive through and self -wash bays. The applicant has also indicated a
6.6.7 -foot landscape strip located on the east property line and the south property
line of Lot 1.
The proposed preliminary plat will require variance from the Subdivision
Ordinance [Section 31-231] the creation of a lot without public street frontage.
The applicant has indicated the lot will be served by a 30 -foot access and utility
easement located on the shared property lines of Lots 1 and 2. Staff is
supportive of the requested variance to allow the creation of a lot without public
street frontage and feels the proposed access is sufficient to access Lot 3 should
the lot develop as a separate parcel from the mini -warehouse to the east.
Staff is supportive of the development plan. Staff feels the applicant submitting a
site plan for each of the remaining lots, as development is proposed, is a very
desirable alternative. Otherwise, to Staff's knowledge there are no outstanding
issues associated with the proposed site plan.
I. STAFF RECOMMENDATION:
Staff recommends approval of the proposed development subject to compliance
with conditions outlined in paragraphs D, E and F of this report.
Staff recommends approval of the requested preliminary plat and the requested
variance from the Subdivision Ordinance to allow the creation of a lot without
public street frontage [Section 31-231].
5
February 6, 2003
SUBDIVISION
ITEM NO.: 16 (Cont,) FILE NO.: Z-7351
PLANNING COMMISSION ACTION: (FEBRUARY 6, 2003)
The applicant was present. There were no objectors present. Staff presented the item
with a recommendation of approval of the proposed rezoning to PCD subject to
compliance with conditions outlined in paragraphs D, E and F of the above report.
Staff stated the proposed development would result in the creation of a three (3) lot plat
which would require a variance to the Subdivision Ordinance. Staff presented a
recommendation of approval of the requested preliminary plat and the requested
variance from the Subdivision Ordinance to allow the creation of a lot without public
street frontage [Section 31-231 ].
There was no further discussion of the item. The item was placed on the Consent
Agenda for approval. The motion carried by a vote of 10 ayes, 0 noes and 1 absent.
[:
February 6, 2003
ITEM NQ.: 16 FILE NO.: Z-7351
NAME: Miracle Land Company Short -form PCD
LOCATION: On the southwest corner of 1-430 and Stagecoach Road
DEVELOPER:
Miracle Development, Inc.
8001 Stagecoach Road
Little Rock, AR 72210
AREA: 3.321 Acres
CURRENT ZONING
NUMBER OF LOTS: 3
ENGINEER:
Global Surveying Consultants, Inc.
15605 Alexander Road
Alexander, AR 72002
FT. NEW STREET: 0
C-3, General Commercial
ALLOWED USES: General Retail
PROPOSED ZONING: PCD
PROPOSED USE: Mini -warehouse, carwash and C-3 uses
VARIANCESMIAIVERS REQUESTED: The creation of a lot without public street
frontage (Lot 3) [Section 31-231].
A. PROPOSAL/REQUEST:
The applicant proposes to subdivide this site into three commercial lots and to
rezone the site to PCD to allow for the development of the site with a carwash on
Lot 1, an unidentified C-3 use to be located on Lot 2 and a mini -warehouse
development on Lot 3 extending from the east.
The plat will require a variance from the Subdivision Ordinance [Section 31-231]
a lot without public street frontage. Lot 3 will be served by a 30 -foot access
easement located on the lot lines of Lots 1 and 2.
February 6, 2003
SUBDIVISION
ITEM NO.: 16 Cont. FILE NO.: Z-7351
The applicant will revise the site plan when development becomes a reality on
Lots 2 and 3.
B. EXISTING CONDITIONS:
The site is a vacant tree covered site currently zoned C-3. The site adjoins the
flood plain/floodway to the south in an area zoned OS. There is a mini -storage
development located to the east of the site adjacent to 1-430. Other uses in the
area include a church located north of the site, a welding shop and a mixture of
auto related uses; ABC Salvage, a tire company, a used car lot.
C. NEIGHBORHOOD COMMENTS:
As of this writing, staff has not received any comment from area residents°. The
Otter Creek Homeowners Association, the Crystal Valley Property Owners
Association and Southwest United for Progress Neighborhood Association, all
property owners located within 200 -feet of the site and all residents, who could
be identified, located within 300 -feet of the site were notified of the public
hearing.
D. ENGINEERING COMMENTS:
PUBLIC WORKS CONDITIONS:
1. Stagecoach Road is classified on the Master Street Plan as a principal
arterial. Dedication of right-of-way to 55 -feet from centerline at all locations
will be required. Provide a survey showing the centerline of Stagecoach
Road.
2. Sidewalks with appropriate handicap ramps are required in accordance with
Section 31-175 of the Little Rock Code and the Master Street Plan.
3. In accordance with Section 31-176, floodway areas must be shown as
floodway easements or be dedicated to the public. In addition, a 25 -foot
wide access easement is required adjacent to the floodway boundary.
4. Show limits of the floodplain on the site plan (floodway limits are already
shown).
5. A grading permit and development permit for special flood hazard area is
required prior to construction.
6. Driveway locations and widths do not meet the traffic access and circulation
requirements of Sections 30-43 and 31-210. The lots must share a single
driveway access centered on the property line. The width of driveway must
not exceed 36 -feet.
7. All driveways shall be concrete aprons per City Ordinance.
8. Stormwater detention ordinance applies to this property.
2
February 6, 2003
UBDIVISION
ITEM NO.: 16 Cont. FILE NO.: Z-7351
9. Obtain permits (barricade/street cut) for improvements within proposed or
existing right-of-way from Traffic Engineering and AHTD prior to
construction in the right-of-way.
10. Prepare a letter of pending development addressing streetlights as required
by Section 31-403 of the Little Rock Code. All request should be forwarded
to Traffic Engineering.
E. UTILITIES AND FIRE DEPARTMENT/COUNTY PLANNING:
Wastewater: Sewer available, not adversely affected.
Entergy: Approved as submitted.
Center -Point Energy: No comment received.
SBC: Approved as submitted.
Central Arkansas Water: A water main extension will be required in order to
provide service to this property. The Little Rock Fire Department needs to
evaluate this site to determine whether additional public and/or private fire
hydrant(s) will be required. If additional fire hydrant(s) are required, they will
be installed at the Developer's expense. Particularly planning for water
service and Fire Department access to Lot 3 should be considered. This
development will have minor impact on existing water distribution system.
Proposed water facilities will be sized to provide adequate pressure and fire
protection.
Fire Department: Fire hydrants will be required. Contact the Little Rock Fire
Department at 918-3752 for additional details.
County Planning: No comment received.
CATA: No comment received.
F. ISSUES/TECHNICAL/DESIGN:
Planninq Division: This request is located in the Otter Creek Planning District.
The Land Use Plan shows Commercial for this property. The applicant has
applied for a PCD with C-3 uses for a mini -storage expansion from the
development to the east and a new carwash. The request is consistent with the
Land Use of Commercial.
City Recognized Neighborhood Action Plan: The applicant's property lies in
the area covered by the Otter Creek/Crystal Valley Neighborhood Action Plan.
The plan contains an objective that discourages construction of large, warehouse
3
February 6, 2003
SUBDIVISION
ITEM NO.: 16 (Cont.) FILE NO.: Z-7351
type facilities, and those of large scale and/or high intensity uses; within the
"heart" of the planning area. This application is located outside the "heart" of the
study area as described by the Neighborhood Action Plan.
Landscape Issues: A land use buffer with an average width of 16.8 feet is
required along the western perimeter of the site. Utility easements cannot count
toward fulfilling this requirement.
A six (6) foot high opaque screen, either a wooden fence with its face side
directed outward, a wall, or dense evergreen plantings, is required along the
western perimeter.
If this project is to be separate from the project to the east, then a minimum 6.7
foot wide landscape strip will be required the entire length of the eastern
perimeter. However, if a portion of the eastern perimeter is to abut -the same
use, then that portion will be exempted from the perimeter landscaping
requirement.
An irrigation system,to water landscaped areas will be required.
Prior to a building permit being issued, it will be necessary to provide approved
landscape plans stamped with the seal of a Registered Landscape Architect.
Building Codes: No comment.
G. SUBDIVISION COMMITTEE COMMENT: (January 16, 2003)
The applicant was present representing the application. Staff presented an
overview of the item to the Committee noting additions, which were needed on
the proposed site plan. Staff requested additional details on Lot 3 including
building location, setbacks and outdoor storage areas identified. Staff also
requested the limits of the floodplain and all utility easements be indicated on the
proposed site plan.
The applicant indicated only Lot 1 had immediate plans for development. He
stated the proposed mini -storage on Lot 3 was not in the near future and when
the plan was developed he would return to the Commission and the Board for
approval of the modified site plan.
Public Works comments were addressed. Staff stated although there were two
existing driveway apron locations, the applicant should remove the western -most
drive and place a shared drive between Lots 1 and 2 near the eastern -most
driveway apron. Staff stated they would not support the two driveway locations
due to their closeness.
0
February 6, 2003
SUBDIVISION
ITEM NO.: 16(Cont.)FILE NO.: Z-7351
Landscaping comments were addressed. Staff stated if the area to the east was
not included in the proposal then the applicant would be required to meet all
landscaping and landuse buffer requirements. Staff suggested the applicant
include the existing mini -storage site with the development plan to reduce the
buffer requirements.
There was no further discussion. The Committee then forwarded the item to the
full Commission for final action.
H. ANALYSIS:
The applicant submitted a revised site plan to Staff addressing most of the issues
raised by Staff and the Subdivision Committee. The applicant has indicated no
development will take place on Lots 2 or 3 at the present time. He has indicated
any future development will require Planning Commission and Board of Directors
approval prior to construction.
In the interim, Lot 1 will development with a carwash. The applicant has included
on the site plan the dumpster location with required screening, the location of the
vacuums, drive through and self -wash bays. The applicant has also indicated. a
6.6.7 -foot landscape strip located on 'the east property line and the south property
line of Lot 1.
The proposed preliminary plat will require variance from the Subdivision
Ordinance [Section 31-231] the creation of a lot without public street frontage.
The applicant has indicated the lot will be served by a 30 -foot access and utility
easement located on the shared property lines of Lots 1 and 2. Staff is
supportive of the requested variance to allow the creation of a lot without public
street frontage and feels the proposed access is sufficient to access Lot 3 should
the lot develop as a separate parcel from the mini -warehouse to the east.
Staff is supportive of the development plan. Staff feels the applicant submitting a
site plan for each of the remaining lots, as development is proposed, is a very
desirable alternative. Otherwise, to Staff's knowledge there are no outstanding
issues associated with the proposed site plan.
I. STAFF RECOMMENDATION:
Staff recommends approval of the proposed development subject to compliance
with conditions outlined in paragraphs D, E and F of this report.
Staff recommends approval of the requested preliminary plat and the requested
variance from the Subdivision Ordinance to allow the creation of a lot without
public street frontage [Section 31-231 ].
I.1
Subdivision Committee Comments
January 16, 2003
Item No. 16 Z-7351
Miracle Land Company Short -form PCD
PI_anninq Staff Comments:
1. Will the spaces indicated on the south property line of proposed Lot 3 be used for
outdoor storage?
2. Lot 3 will require a variance from the Subdivision Ordinance to allow a lot without
public street frontage.
3. Provide a single drive to correspond with the access easement.
4. Indicate the floodplain and floodway on the proposed site plan.
5. Provide a utility easement on the site plan to allow utilities to be extended to Lot 3.
6. Provide the days and hours of operation.
7. Provide any proposed signage along with details (style/height/area).
8. Provide any proposed dumpster locations.
9. Detail any proposed parking and service drives for the mini -warehouse.
10. Provide building setback dimensions from all property lines.
11. Include the area to the east of the site (the existing mini -storage) in with this
proposed area. If not provide all required setbacks, landscaping and land use
buffers for each lot.
12. Provide notification of property owners located within 200 -feet of the site complete
with the certified abstract list, notice form with affidavit executed and proof of
mailing.
Variance/Waivers: None requested.I "tl_
Public Works:
1. Stagecoach Road is classified on the Master Street Plan as a principal arterial.
Dedication of right-of-way to 55 -feet from centerline at all locations will be required.
Provide a survey showing the centerline of Stagecoach Road.
2. Sidewalks with appropriate handicap ramps are required in accordance with Section
31-175 of the Little Rock Code and the Master Street Plan.
3. In accordance with Section 31-176, floodway areas must be shown as floodway
easements or be dedicated to the public. In addition, a 25 -foot wide access
easement is required adjacent to the floodway boundary.
4. Show limits of the floodplain on the site plan (floodway limits are already shown).
5. A grading permit and development permit for special flood hazard area is required
prior to construction.
6. Driveway locations and widths do not meet the traffic access and circulation
requirements of Sections 30-43 and 31-210. The lots must share a single driveway
access centered on the property line. The width of driveway must not exceed 36 -
feet.
7. All driveways shall be concrete aprons per City Ordinance.
8. Stormwater detention ordinance applies to this property.
9. Obtain permits (barricade/street cut) for improvements within proposed or existing
right-of-way from Traffic Engineering and AHTD prior to construction in the right-of-
way.
10. Prepare a letter of pending development addressing streetlights as required by
Section 31-403 of the Little Rock Code. All request should be forwarded to Traffic
Engineering.
Utilities and Fire Department/County Planning:
Wastewater: Sewer available, not adversely affected.
Entergy: Approved as submitted.
Center -Point Ener y: No comment received.
SBC: No comment received.
entral Arkansas Water: A water main extension will be required in order to provide
service to this property. The Little Rock Fire Department needs to evaluate this site
to determine whether additional public and/or private fire hydrant(s) will be required.
If additional fire hydrant(s) are required, they will be installed at the Developer's
expense. Particularly planning for water service and Fire Department access to Lot
3 should be considered. This development will have minor impact on existing water
distribution system. Proposed water facilities will be sized to provide adequate
pressure and fire protection. Contact Central Arkansas Water at 992-2438 for
additional details.
Fire Department: Fire hydrants will be required
Department at 918-3752 for additional details.
County Planning: No comment received.
CATA: No comment received.
Planning Division:
Contact the Little Rock Fire
Landscape Issues: A land use buffer with an average width of 16.8 feet is required
along the western perimeter of the site. Utility easements cannot count toward fulfilling
this requirement.
A six (6) foot high opaque screen, either a wooden fence with its face side directed
outward, a wall, or dense evergreen plantings, is required along the western perimeter.
If this project is to be separate from the project to the east, then a minimum 6.7 foot
wide landscape strip will be required the entire length of the eastern perimeter.
However, if a portion of the eastern perimeter is to abut the same use, then that portion
will be exempted from the perimeter landscaping requirement.
An irrigation system to water landscaped areas will be required.
Prior to a building permit being issued, it will be necessary to provide approved
landscape plans stamped with the seal of a Registered Landscape Architect.
Revised plat/plan: Submit four (4) copies of a revised site plan (to include the
additional information as noted above) to staff on Wednesday, January 22, 2003.