Loading...
HomeMy WebLinkAboutZ-7334-A Map 3NOTE-'): 1. THE SIZE, HEIGHT AND DIRECTION OF THE ANTENNA SHALL BE ADJUSTED TO MEET SYSTEM REQUIREMENTS. 2. CONTRACTOR SHALL VERIFY HEIGHT OF ANTENNA WITH T -MOBILE PM. 3. ALL ANTENNA AZIMUTH ARE TO BE FROM TRUE NORTH. 4. ALL, DISTURBED AREAS WILL BE REPLACED TO ORIGINAL CONDITION. NEW T -MOBILE 10'-0" X 15'-0" GONGRETE FAD, NEN T-MO1311 F BTS EQUIPMENT CABINETS NEW 6-0" HIGH WOOD PRIVACY FENCE. SEE C -'T NEW T -MOBILE 24" WIDE GABLE BRIDGE 1-2" PVG UNDERGROUND FOR FUTURE TELCO 5H2VIGE f 220'-0" 3 I 1-2" PVG ` FOR TELCO SERVICE LSO. -T t 220'-0" tj ty q 31 32 J34 / 3 24, 0 Telco Ped T Telco P ' IF -Ir IN FIELD) _ POWER 2" EX15T1N65 TELEPHONE GO ISTING PEDE5TAL TO BE UTILIZED UTILI PO x � ±1101 " >, ? EX15 LITY O Q POLE TO UTILIZED X' o o I X ?fes g n t Tho t DIST. TO I EASE FROM CENTER OF TOWER DIST. TO PROPERTY LINES NORTH 25'-O" 173'-1 " SOUTH 25'-O" 265[ -ill EAST CIO -if" 501-O" WEST 40'-1" 150'-7" ZONE I-2 RESIDENTIAL ® Pmt Tract 'Tf x x X — x o/ Pw'. Po t O°AZ. � 1 i � (VER, IN PI I• x 7, 6 S 4 31J 0 f -0" WIPE 6rOvvet t ac NEW 2 1 DMI AGG IAJI N 1 x I TY METER I RA 3 I ZONE 1-2 OVERALL SITE PLAN 5CAL.E : 1a=60' -C" In 1 NEN 30'-0" WIDE 1 ACCESS EASEMENT AND DRIVE EXISTING 20'-0" 1^1I1 ROLLING GATT= i , ON 0 ; `, . •, < a 0 :- FA — NEW 15C " MONOPC SEE IM- • � T � F <,, At <p `-E PANEL AT1N .. A — NEN GRA <� . 1 *fl --)IJT ENTIRE CC"' 1POU" Rt `r IAt t jjjf ro I Al i i lei J A • /Q w (VE e NEW 5 50' j LEASE FA — NEW 15C " MONOPC SEE IM- '4675 BY 6- — W -HT -I'_ `-E PANEL AT1N — NEN GRA , EL THROU6Ft --)IJT ENTIRE CC"' 1POU" `r t jjjf A • /Q FIELD) SIGN NOTES ONO TRE55PA551N6 SIGN 2O RF WARNING 516N 3� CAUTION - RFE 516N, ®EGG REGISTRATION NUMBER FOR FULL 516N DETAILS AND LOCATIONS SEE 310-2 PRIVATE PROPERTY NO TRESPASSING VIOLATORS WILL BE PROSECUTED U1111115- • i I/ RED BAGKCM O P/ WHITE LETTERING 1Q NO-TRESSPASSING SIGN 18' WIDE X 24' HIGH CAUTION +- SOH BAGK6ROIIND W/ BLACK LETTERING RADIO FREQUENCY - —WHITE BAGS W/ ENVIRONMENT BLACK LETTERING AREA AND YELLOW 5YMBOL Q CAUTION RFE 3 SIGN DETAILS 12' WIDE X 18' HIGH 5GALE: NOT TO SCALE SITE ID# 000000 VERIFIED 911 STREET ADDRESS CITY, STATE AND ZIP CODE FOR LEASE INFORMATION CALL FOR 24 HOUR EMERGENCY SERVICE CALL ID SIGN 24" WIDE X 8" HIGH FCC TOWER REGISTRATION NO. 1234567 LT.6RAY W/ BLACK LETTERIN6 ® FCC REGISTRATION SIGN 24' WIDE X 4' HIGH NOTE: EQUIPMENT PL.A11 .RM AND ANTENNA5 ARE DE516NED TO MEET LOCAL HUILDIN6 CODES, AND AN5I/EIA.MA-222-F STRUGTURAt- STANDARDS FOR STEEL. ANTENNA SUPPORTING STRUCTURES. THE DOE -516N WIND SPEED 15 qO MPH. GENERAL NOTES 1. EQUIPMENT PLATFORM AND ANTENNAS ARE DE516NED TO MEET LOCAL BUILDING CODES, AND AN51/EIA/TIA-222-F STRUCTURAL STANDARDS FOR STEEL ANTENNA 51,11PPORTIN6 STRUCTURES. THE DIE -516N WIND SPEED 15 qO MPH. 2. ALL STRUCTURAL STEEL SHALL BE HOT -DIPPED GALVANIZED AFTER FABRICATION. 3. EXI5TIN6 VEGETATION WILL BE REMOVED IN51DE LEASED AREA AND ACCESS DRIVE. 4. ALL STRUCTURAL STEEL SHALL BE DESIGNED, FABRICATED, AND ERECTED IN ACCORDANCE WITH AI5C SPECIFICATION (LATEST EDITION). 5. ALL CAST IN PLACE CONCRETE SHALL BE MIXED AND PLACED IN AG..ORDANCE WITH AGI 318 AND AGI 301. 6. FACILITY 15 UNMANNED AND NOT FOR HUMAN HABITATION (HANDiGAPPED AC,( -,E-55 NOT REQUIRED). 7. THERE WILL BE NO OUTDOOR LIGHTING WITH THE EXCEPTION OF EMER&ENGY CONDITIONS. 8. FACILITY HAS NO PLUMBING. q. FACILITY WILL BE INDEPENDENTLY POWERED WITH SEPARATE METER. 10. ANTENNA PLATFORM AND ANTENNA INSTALLATION SHALL BE CONDUGTED BY FIELD CREN5 EXPERIENCED IN THE ASSEMBLY AND ERECTION OF RADIO ANTENNAS, TRANSMISSION LINES, AND SUPPORT STRUCTURES. 11. CONTRACT COMPANIES AND THEIR EMPLOYEES SHALL OBSERVE AND PRACTICE ALL 0.5.H.A. SAFETY GUIDELINES WHILE PERFORMING SERVICE FOR T -MOBILE. 12. WHERE A TOWER DOES NOT HAVE A PERMANENT FALL PROTECTION 5Y5TEM, THE CONTRACT COMPANY 15 RESPONSIBLE FOR PROVIDING A SUITABLE SYSTEM FOR ITS EMPLOYEES. 13. CONTRACTOR SHALL PERFORM A SAFETY INSPECTION PRIOR TO COMMENGIN6 ALL WORK ACTIVITIES AT A T -MOBILE. LEASED OR OWNED SITE. ONNER SHOULD BE IMMEDIATELY NOTIFIED OF SAFETY HAZARD(5) FOUND DURiN6 THE INSPECTION THAT COULD CAUSE BODILY HARM OR ENDAN&ERMENT TO LIFE OR THAT COULD GAJSE DAMAGE TO PROPERTY. ALL WORK SHALL BE HALTED UNTIL SUCH TIM=_ T� E REPORTED 5AFETY HAZARD CORRECTED. THE SAFETY HAZARD, IF POSSIBLE, SHOULD BE GORREGTED BY THE CONTRACTOR WHILE ON SITE, AFTER THE CONTRACTOR HAS NOTIFIED OWNER. OF THE HAZARD AND HAS RECEIVED APPROVAL FROM OWNER TO PERFORM THE GORREGTION. INITIALS U J IL O C7 z 0 co w 0 z 0 h U z 0 U h m PROPERTY OWNER/REP. AGWI51TION (L0 0 W -T COMMUNICATION DESIGN GROUP, LLC 39 E. SCULLY DRIVE SCHAUMBURG, LLINOIS 60103 ph. 118471 863-3640 fox. 1847) $95-6685 T • •Mobiles 12120 COLONEL GLENN ROAD SUITE 1000 LITTLE ROCK, AR 72210 2 10-14-02 FOR CONSTRUCTION 1 10-06-02 FOR CLIENT REVIEW AR1005"B OZARK EQUIPMENT 3100 INTERSTATE 30 LITTLE ROCK, AR 72206 PULASKI COUNTY SITE PLAN DATE: 09-28-02 SCALE: AS NOTED DRAWN: MJR W -T # T02388 SHEET