Loading...
HomeMy WebLinkAboutZ-7246-B MapI CONTRACTOR TO CALL CROWN CASTLE CONSTRUCTION MANAGER NO LESS THAN 48HRS BEFORE CONSTRUCTION START. M2M 00 SPECTRUM NETWORKS SITE NAME: m1B+T G R P DOWNTOWN WEIST M2M SITE NUMBER: BU NUMBER: M2M(A%g ARBEA090 S78k SPECTRUM NETWORKS ; � �;� ; .,,;.r�;�!� � ;VEl Y -�'^'�"'-'w - w t'� 131 'EAST CAMELBACK ROAD, SUITE 450 �j�/ rlefi lllilyeV�'!`^''!"r''�S "TP' PHOENIX, AZ 85016 711 S IZARD STREET cJbb'r';t C ndi:ia `Otact On V. U. Pes LITTLE ROCK, AR 72201 uatL:I CROWN ABY DEV,. T!Ol',i FROM APPROVED S,,T� ['ice N `v, 0 1 D 'H i S PERfl,'lIT. EXISTING 70' MONOPOLE 7- 11,04 PROJECT SUMMARY LOCATION MAP .B ! •.. W. q SITE NAME: DOWNTOWN WEST I�I� °�hS.. I .._ � SITE NUMBER: ARBEA090 .. D 1 I,� - rfakltari� St Vii" a �arK SITE ADDRESS: 711 S IZARD STREET _if SI L{ttjg'ROW RI�a lrnrrcP}tt reT LITTLE ROCK, AR 72201It W- II rlllr JURISDICTION: LITTLE ROCK TOWNSHIP TOWER OWNER: CROWN CASTLE b St 370 MALLORY STATION RD, SUITE 505ap WY'yt?+ , U " .m. _w _ _ I I _ DovubrrWRUY�r - FRANKLIN, TN 37067 � - - � _ 1� � I •• __ 4"_ CONTACT: CHUCK DUNCAN �� (501) 366-0674 - ] j ,�2•UqE-15Ar- i NAD83 • _ X767. 4 LATITUDE: 34' 44' 33.4" �! I E.-a ..yT_�� J .f '1 1. vIf .St . o . �h'St.. LONGITUDE: -92' 16' 51.3" S( ra cwuw �a I f I � y�'-�kr I" ' ..�r1N-'� , r• -- - _ 1aK, St :x . l I CUSTOMER/ M2M SPECTRUM NETWORKS, LLC APPLICANT: 3131 EAST CAMELBACK ROAD, SUITE 450 J_ PHOENIX, AZ 85016. RANDY COFFMAN i _ d 'prcrif31 — t-'+ _ i jSj Lv 431ttPark CONTACT: {� (855) 743-6478 4 +'- In_,:•(san gam Dr _' T301 }tk� 40 a OCCUPANCY TYPE: UNMANNED A.D.A. COMPLIANCE:W. FACILITY IS UNMANNED AND NOT FOR HUMAN HABITATIONI ~ l NO SCALE DESIGN INFORMATION DRIVING DIRECTIONS A&E FIRM: 82600 DEERFIELD PARKWAY, SUITE 100 DEPART LITTLE ROCK NATIONAL AIRPORT ONTO ANNIE M BANKHEAD DR [BANKHEAD DR], TAKE RAMP (RIGHT) ONTO 1-440. ALPHARETTA, GA 30004 AT EXIT 138A, TAKE RAMP (RIGHT) ONTO 1-30 [US -167], AT EXIT 139B, TAKE RAMP (RIGHT) ONTO 1-630. AT EXIT 1B,LO CAROLINE BUNT, P.E. TAKE RAMP (RIGHT) ONTO 1-630 W, TURN RIGHT ONTO S IZARD ST AND ARRIVE AT DOWNTOWN WEST. (770) 826-9589 ELECTRIC PROVIDER: ENTERGY (800) 368-3749 TELCO PROVIDER: AT&T (800) 288-2020 CODE COMPLIANCE PROJECT DESCRIPTION DO NOT SCALE DRAWINGS ALL WORK SHALL BE PERFORMED AND MATERIALS INSTALLED IN THE PROPOSED PROJECT INCLUDES: ALL DRAWINGS CONTAINED HEREIN ACCORDANCE WITH THE CURRENT EDITIONS OF THE FOLLOWING CODES INSTALL (4) OMNIS AND MOUNTS AT 55'. ARE FORMATTED FOR 11X17. AS ADOPTED BY THE LOCAL GOVERNING AUTHORITIES. NOTHING IN THESE INSTALL (4) 7/8• FEEDUNES. CONTRACTOR SHALL VERIFY ALL PLANS AND EXISTING PLANS IS TO BE CONSTRUED TO PERMIT WORK NOT CONFORMING TO INSTALL (1) RV -78 IN (1) 3'x3' NEMA ENCLOSURE & (1) DIMENSIONS AND CONDITIONSTIFFON THE JOB SITE AND THESE CODES: LOAD CENTER MOUNTED TO PROPOSED H -FRAME IN 5'x5' AREA. SHALL IMMEDIATELY NOTIFY THE ENGINEER IN WRITING CODE TYPE CODE INSTALL ICE BRIDGE. OF ANY DISCREPANCIES BEFORE PROCEEDING WITH BUILDING DWELLING IBC 2006 INSTALL POWER AND TELCO UTILITIES. THE WORK OR BE RESPONSIBLE FOR SAME. / INSTALL GROUNDING SYSTEM FOR H -FRAME AND M2M AREA STRUCTURALIBC 2006 SEE SHEETS GN -1 & GN -2 FOR MECHANICAL IMC 2003 ADDITIONAL CONSTRUCTION NOTES ELECTRICAL NEC 2008 CALL ARKANSAS ONE CALL a (800) 482-8998 a CALL 3 WORKING DAYS BEFORE YOU DIG! o WC) w00 J U0 00 �o cq A PROJECT NO: 90930.001.01 CHECKED BY: CWB ISSUED FOR: REV DATE DRWN DESCRIPTION A 412f14 CJD PRELIMINARY R 1 414/14 1 SMM I PRELIMINARY Expires517 1N1.2431/15/ �I l/ LNEF E. 4/7/14 R IS A Y1DLA1KIN OF tAw fmFffY PERSON, UNffM i11EY AAE AC11NO Mom1}It OIfmCNON OF A I.ICR� Pk0Ff5Y+�aeWl p1pNEER to ,4.1ER 1Ii6 ooe,AlElrr. SHEET NUMBER REVT-1 ESII V ESTIMATED COAX LENGTH: ±105' ESTIMATED ICE BRIDGE LENGTH: ±4'-0" DIAMETER OF MONOPOLE AT 55': ±24" NOTES: 1. CONTRACTOR TO PROVIDE WEATHERPROOFING KITS, SNAP -INS, HANGERS, HOISTING GRIPS,(2) 4" GALVANIZED PIPES WITH (4) UNISTRUT (2 ON FRONT & 2 ON BACK) FOR THE H -FRAME, WEATHERPROOFING, METER CAN, DISCONNECT, 4 OUTLET AC PLUGIN IN CABINET, COLORED MARKING TAPE AND CABINET GROUNDING MATERIAL. 2. M2M TO PROVIDE ANTENNA, COAX, JUMPERS, CABINET, ICE BRIDGE, GROUND KITS AND WAVEGUIDE IF NEEDED. 32'-0" X X X X x x x x x X ._ . PROPOSED H -FRAME WITH NEMA CABINET, LOAD CENTER do SINGLE METER. FRONT OF METER MUST BE A MIN. OF 4' AWAY FROM FENCE RE 1/C-3-•- �� PROPOSED 5'x5' M2M AREA i PROPOSED 7' ICE BRIDGE + I RE 3/C-3 70' MONOPOLI: J RE: 1/C—•2 + i -I- + •E + + + 1 l EQUIPMENT PAD UTILITY FRAM T ; j - — 3'--0" WORKIN Z I CLFARANCF I I X COMPOUND LAYOUT _- 1 SCALE: ' l U, 11 5' 1 o' CONTRACTOR TO FIELD VERIFY ALL DIMENSIONS PRIOR TO CONSTRUCTION NOTE: CONTRACTOR SHALL PROVIDE POSITIVE DRAINAGE AWAY FROM PROPOSED SHELTER OR FENCED COMPOUND AT A MINIMUM 1% AND MAXIMUM 5% GRADE. CONTRACTOR TO CALL CROWN CASTLE CONSTRUCTION MANAGER NO LESS THAN 48HRS BEFORE CONSTRUCTION START. .1 =T3 B+T GRP M2M SPECTRUM NETWORKS 3131 EAST CAMELBACK ROAD, SUITE 450 PHOENIX, AZ 05016 CROWN r GA o L L Q PROJECT NO: 90930.001.01 CHECKED BY: CD CD w ISSUED FOR: C) W � 00 00 W PRELIMINARY B 4/4/14 SWM PRELIMINARY Q O cw CONSTRUCTION REVISION: c -a � H p a PROJECT NO: 90930.001.01 CHECKED BY: CWB ISSUED FOR: REV DATE I DRWN I DESCRIPTION A 4/2/14 CJD PRELIMINARY B 4/4/14 SWM PRELIMINARY O 4/7/14 SMM CONSTRUCTION B&T ENGINEERING, INC. 1517 Expires 1 31 j1S Wp.11i�89 t{r D E. 4/7/1-44 R IS A HOUO UNUSS Tic, ATANAANt' PERSOeI 11iC GWEC[ILW OF A UR7GfT A 0rfS$10W. ETIpNEER In /P.IFA TITS OP[U�EN7. SHEET NUMBER: REVISION: c-1 0 TOP OF TOWER ELEV. = 70' EXISTING ANTENNAS ELEV. = 70'-D" TOWER CALE N ESEVATION (POSED M2M ANTENNAS ' (4). RAD CENTER 55' D: 13 -XT OMNIS '5M-SF7SNM OMNIS COAX TO PROPOSED MOUNT RE: 2/C-2 EXISTING 70' MONOPOLE ANY AND ALL TOWER MOUNTED EQUIPMENT MUST NOT TRAP OR RUB WITH EXISTING SAFETY CLIMB 1 CONTRACTOR TO CALL CROWN CASTLE CONSTRUCTION MANAGER NO LESS THAN 48HRS BEFORE CONSTRUCTION START. 2 3/8' OD x 24" PIPE COMMSCOPE P/N: MT -648 2 3/8" OD x 48' PIPE COMMSCOPE P/N: MT -1150 STAND-OFF ARM WITH U -BOLTS COMMSCOPE P/N: MC-SAI2-B INSTALL SO MT -650 CAN BE MOUNTED HORIZONTALLY, 1. GENERAL: PROVIDE ALL LABOR, EQUIPMENT, AND MATERIALS NECESSARY FOR RECEIVING, INSTALLING, TESTING, AND ADJUSTING ANTENNA CABLES FROM THE Jf3 B+T G R P ANTENNA TO THE CONNECTIONS AT THE BASE TRANSCEIVER STATION (BTS). THIS SHALL INCLUDE ALL EQUIPMENT SHOWN OR REQUIRED FOR A COMPLETE OPERATING SYSTEM. ANTENNA, ANTENNA CABLES, CONNECTORS, AND FITTINGS SHALL BE THIRD PARTY FURNISHED COMPONENTS AS SHOWN ON THE BILL OF MATERIALS. 2. MATERIALS A. ANTENNA CABLES: 4 7/8" COAX B. ANTENNA CONNECTORS: PER MANUFACTURER C. CABLE HANGERS: INSTALLED AT MAXIMUM 4' SPACING D. GROUNDING KITS: AS SPECIFIED IN NOTE E BELOW. 3. INSTALLATION A. ANTENNA CABLE LENGTHS SHALL BE FIELD MEASURED. INSTALLER SHALL NOTIFY M2M PRIOR TO PURCHASE OF CABLE OF THE OVERALL LENGTH REQUIRED. B. ALL CABLE CONNECTIONS OUTSIDE SHALL BE COVERED WITH WEATHERPROOFING TAPE. C. THE MINIMUM BENDING RADIUS FOR ALL ANTENNA CABLES SHALL BE AS SHOWN BELOW OR PER THE MANUFACTURER, WHICHEVER IS MORE CONSERVATIVE: CABLE IN AIR OR CABLE TRAY IN CONDUIT 1/2" 5" 10" 7/8" lo" 18" 1-1/4" 15" 24" 1-5/8" 20" 28" D. CABLES SHALL BE INSTALLED WITH THE MINIMUM NUMBER OF BENDS. CABLE SHALL NOT BE LEFT UNTERMINATED IN THE FIELD. E. GROUNDING KITS: AFTER INSTALLATION OF GROUND STRAPS, THE CONNECTIONS SHALL BE MADE WEATHER TIGHT USING WEATHERPROOF KITS AS IDENTIFIED ABOVE. GROUND PIGTAILS SHALL BE BROUGHT OUT IN THE DOWNWARD DIRECTION FROM THE CONNECTION TO THE ANTENNA CABLE WITHOUT ANY SHARP BENDS (MINIMUM RADIUS 10") AND CONNECTION SHALL BE MADE TO GROUNDING SYSTEM. 4. COAX & JUMPER COLOR CODE 800/900-TX1/RCV 1, RED, 1 STRIPE 800/900-TX2/RCV 2, RED, 2 STRIPES 217/220-TX1/RCV 1, YELLOW, 1 STRIPE 217/220-TX2/RCV 2, YELLOW, 2 STRIPES , PROPOSED 800MHz OMNI ANTENNA PROPOSED 200MHz OMNI ANTENNA UNNER_SAL RING MOUNT COMMSCOPE P/N: MC-RM1030-3 INSTALL PER MFG. SPECS. MONOPOLE (2) CROSSOVER PLATES COMMSWPE P/N: XP -2020 INSTALL 1 AT BOTH ENDS OF MT -650 INSTALL SO MT -480 CAN BE MOUNTED VERTICALLY. DUAL MOUNT CONFIGURATION MOUNT ANTENNA IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDED PROCEDURE. DETAIL FOR MOUNTING PURPOSES ONLY. NOT ALL TOWER MEMBERS SHOWN. ANTENNA MOUNT DETAILS SCALE: N.T.S. NORTH r D. 270' + 90' �. 180' EXISTING MONOPOLE I PROPOSED OMNI ON PROPOSED MOUNT (4 TOTAL) REFER TO STRUCTURAL ANALYSIS TO DETERMINE FEEDLINE PLACEMENT. ALL OTHER FEEDLINES NOT SHOWN FOR CLARITY PROPOSED: (4) 7/8" COAX I 2'-0" MONOPOLE DIAMETER AT MOUNTING LEVEL I TRANSMISSION LINE DIAGRAM SCALE: N.T.S. PROPOSED 2OOMHz OMNI ANTENNA PROPOSED 800MHz OMNI ANTENNA M2M'\014) SPECTRUM NETWORKS 3131 EAST CAMELBACK ROAD, SURE 450 PHOENIX, AZ 65016 CROWN t�) I L r PROJECT NO: 90930.001.01 CHECKED BY: CWB ION O REV DATE Wo A 4/2114 CJD PREUMINARY cn * 0 4/:/14 SMM �O NP4 REVLSION: C-2 c rel u z r. � A PROJECT NO: 90930.001.01 CHECKED BY: CWB ISSUED FOR REV DATE DESCRIPTION A 4/2114 CJD PREUMINARY JDRWN 6 4/.'/14 SMM PREUMINARY 0 4/:/14 SMM I CONSTRUCTION B&T ENGINEERING, INC. 1517 Expires 1 31/15 I r �D E. 4/7/14 R IS A NiDLANDN OF NAW FORANI PERSON. UNLESS THEY ARE ACnNG UNDER THEDMID710N OF A 11CFAL TO ALTER THIS DOCUMENT. SHEET NUMBER: REVLSION: C-2 0_ CONTRACTOR TO CALL CROWN CASTLE CONSTRUCTION MANAGER NO LESS THAN 48HRS BEFORE CONSTRUCTION START. 3" (3 1/2" O.D.) GALV. STEEL PIPE WITH GALV. STEEL CAP (TYP.) PROPOSED LOAD CENTER, `. SCHNEIDER ELECTRIC PN/: Q0120M10ORB (OR EQUAL) GU—B4355 GALV. U—BOLT ASSEMBLY PROPOSED COMLINE CABINET P/N: — ECL906050P WITH T20 AC UNIT MOUNTED INSIDE. MOUNT CABINET PER MANUFACTURERS' SPECIFICATIONS. PROPOSED 2" FLEX CONDUIT FROM— LOAD CENTER TO NEMA CABINET 3/4" PVC CONDUIT WITH #2 BONDED TO NEUTRAL, TYPICAL. 2" PVC CONDUIT WITH PULL ROPE FOR POWER TO UTILITY COMPANY POINT OF CONNECTION FINISHED GRADE --1 TRANSITIONING GROUND RE: 8/G-2 6" WIDE METALLIC HTEL �. 1 .i I I A WARNING/LOCATOR TAPE AT 12" DEPTH MT—C649.02 36" INSERT. TO PREVENT CORROSION, ASSURE THAT THE PIPE SLEEVE IS COMPLETELY BELOW GROUND LEVEL AND ENCASED IN CONCRETE. 1'-0" TIE INTO EXISTING GROUND RING 5'-0" 4'-0" RUBBER END CAPS ON UTILITY RACK ALL UNISTRUT ENDS 0 I co z 0 0 j CADWELD 2" PVC CONDUIT WITH PULL BOX TO TELEPHONE COMPANY POINT OF CONNECTION OR PER SERVING TELEPHONE COMPANY REQUIREMENTS NOTE: 1. ALL EXPOSED ELECTRICAL CONDUIT MUST BE GALVANIZED STEEL RIGID CONDUIT. 2. THREADLESS CONNECTORS ARE NOT ALLOWED. 3. EMT CONDUIT CAN ONLY BE USED INSIDE. 4. USE ONLY COMPRESSION TYPE FnT1NG5 ON EMT CONDUIT. 5. USE ONLY STRANDED CONDUCTORS FOR ALL ELECTRICAL WIRING. (EXCEPT TELCO AND THERMOSTAT) 6. USE SCHEDULE 80 CONDUIT UNDER DRIVEWAYS AND/OR ANY VEHICLE CROSSING AREA. Cj' EQUIPMENT RACK ELEVATION SCALE- N.T.S. ECL906050P COMLINE CABINET T20 A/C UNIT C 0 M L I N E CABINET & A/C UNIT SCALE: N.T.S. 7" WIDE BRIDGE C 12" BRACKET ASSI CUSHION HANGER 3 1/2"0 PIPE CO (VALMONT PN# B1 OR EQUIVALENT) FINISH FLUSH TO FINISH GRADE TRANSITIONING GR RE: 8/G-2 12" CONCRETE PII TIE INTO EXISTING GROUND RING T� ^AP (TYP.) ICE BRIDGE DETAIL SCALE: N.T.S. jpB+T GRP M2M SPECTRUM NETWORKS 3131 EAST CAMELBACK ROAD. SUITE 450 PHOENIX, AZ 85016 �cRo_w_ N o Ocl, [� N w 00 �o NP4 cn a PROJECT NO: 90930.001.01 CHECKED BY: CWB ISSUED FOR: REV I DATE DRWN I DESCPoPIION A 1 4/2/11 1 CJD I PRELIMINARY 6 1 4/4/14 1 SMM I PRELIMINARY B&T ENGINEERING, INC. 1517 Expires 13,(31/15 r 1/ No to B <I. E. 4/7/1 It IS A MOIAT" OF LAW' FOR ANY PE1t501t "fiM 111CY ARE ACTING UNDER tmC DINSCMN OFAT[X i o ALTERAE mM 4 . SHEET NUMBER: REVISION: C-3 0