Loading...
HomeMy WebLinkAboutZ-7246-A MapSITE NAME: S�°�'�-�wnl��s� Sprint SITE NUMBER. LR03XC001 8580 SPRINT PARKWAY OVERLAND PARK, KANSAS 66251 ■ STRUCTURE TYPE: MONOPOLE s ri nt • ARKANSAS �`��" �-���`"�5 � doe 1 ERI CSSON NETWORK VISION MMBS LAUNCH 6100 SPRINT PARKWAY OVDTLWD PARK KANSAS 66251 PROJECT SUMMARY DRIVING DIRECTIONS VICINITY MAP LIST OF DRAWINGS ;flii4w PBre[ s` ' �J --�tii �� - 1 C_NFFT Tfil F RESP ENGR A S S c 1_ DEPART FROM. I !! 9900 West 109 h street, Suite 300 SITE NAME: ti�/� j(ai Yl (.t)LS'�' FROM THE [NTERCHPNGE OF 1-540 & US -62 IN + } r ) T-1 TITLE MEET MLO/TMS Ovedend Park, Kansas 66210 SITE NUMBER: I(603XC001 BENTONVILLE. ARKANSAS. CONTINUE ON 1-540 SOUTH. TAKE � 1 ��� xTi Phone: 913438-T700 Fax: s13 43&7777 SITE ADDRESS: 711 SOUTH IZARD STREET EXIT 20 ON THE LEFT TO MERGE ONTO 1-40 E TOWARD r LITTLE ROCK, ARKANSAS 72201 NJAA/iITTLE ROCK. TAKE EXIT 152 FOR A-1 OVERALL SITE LAYOUT MLO AR-385/MACARTHUR DR. AT THE TRAFFIC CIRCLE, TAKE THEnl R i'- MLO APN#: - 3R0 EXIT ONTO W BROADWAY ST. TURN RIGHT ONTO LIS A-2 SITE ELEVATIONS AR -365 S/US-67/US 70B W. TURN RIGHT ONTO W. 7TH LATITUDE; N 34.7425• (NAD 83) A-3 EQUIPMENT LAYOUTS MLO ST. TURN LEFT ONTO S. IZARD ST. >~ j f A-4 ANTENNA PLANS MLO LONGITUDE: W 92.2808• (NAD 83)� t7 ~ Li A-5 COLOR CODING DETAILS MLO GROUND ELEVATION: 311' (AMSC) r "-, A-6 DETAILS MLO JURISDICTION: PULASKI COUNTY 71Jt) r A-7 DETAILS MLO ZONING: - j J A-8 DETAILS MLO A-9 PLUMBING DIAGRAMS STATE CERTIOF FICATE O ARKANSAS MLO CERTIFICATE OF AUTHORIZATION 7l774 �i y� A-10 RFDS SHEET "l, 09/31/12) MLU RESPONSIBLE ENGINEERS: MLO MICHAELL.OWENS 134W STRUCTURAUCIML 1:V TMS �� �} ] TMS TERRANCE M SUPER 9717 ELECTRICAL SCOPE OF WORK —4� E-1 UTILITY SITE PLAN _ tl �� , TMs 1. THE WIRELESS COMMUNICATION FACILITY IS NOT INTENDED FOR 11i St fW Aq - E-2 DETAILS TMS NOTICE THIS DRAWING HAS NOT BEEN PUBLISHED AND IS THE HUMAN OCCUPANCY _ E-3 DETAILS r SOLE PROPERTY ID SSC, INC. AND IS LEND T INCONSIDERATION BORROWER 2. THIS FACILITY DOES NOT REQUIRE PORTABLE WATER AND WILL FOR HE LOANIR OF THIS AL USE ONLY, AND R CONSIDERATION OF THE LOAN OF THIS DRAWING, THE BORROWER PROMISES NOT PRODUCE ANY SEWAGE. - '� G-1 GROUNDING PLAN, RISER AND NOTES TMS AND AGREES TO RETURN IT UPON REQUEST AND AGREES THAT .� IT WILL NOT BE REPRODUCED, COPIED, LEND OR OTHERWISE 3. THE SCOPE OF WORK CONSISTS OF MODIFYING THE EXISTING CONTACTS APPROVALS DISPOSEDOFDIRECTLHANY OR INDIRECTLY, IS USED FOR ANY G-2 DETAILS TMS PURPOSEOTHERTHANFORWHICHITOFURNISHED WIRELESS INSTALLATION: TMS G-3 DETAILS DESIGNER: T.N TAYLOR • REMOVAL OF (3) EXISTING EQUIPMENT CABINETS APPLICANT: SPRINT PCS LEAD EE: T. SUPER • INSTALLATION OF (2) NEW EQUIPMENT CABINETS 6580 SPRINT PARKWAY GN -1 GENERAL NOTES MLO/TMS • REMOVAL OF (8) EXISTING ANTENNAS OVERLAND PARK, KS 66251 LEAD CENSE: M. OWENS • INSTALLATION OF (3) NEW ANTENNAS SPRINT REPRESENTATIVE DATE • INSTALLATION OF (12) NEW RRU'S (REMOTE RADIO UNITS) T4l4ERf..PROPERTY OK'bICL�: DOUG BRANDON PROPERTIES, INC SUBMITTALS 1101 SOUTH UNIVERSITY NO. DATE DESCRIPTION BY LITTLE ROCK, AR 72204 A 10 /12 =ORR WM � SPRINT RF ENGINEERING DATE ENGINEERING CONSULTANTS: SSC, INC. APPLICABLE CODES ssoo w 1 09TH sr, SUITE 300 OVERLAND PARK, KS 66210 SITE OWNER DATE INTERNATIONAL BUILDING CODE, 2006 EDITION KEVIN VAN SHELTON KEISLE EISLING SITE NAME (913) 438-7700 NATIONAL ELECTRICAL CODE, 2005 EDITION SPRINT CONSTRUCTION MANAGER DATE DOWNTOWN WEST .Al; ANTHONY RYAN ERICSSON THE ABOVE PARTLES HEREBY APPROVE AND ACCEPT THESE DOCUMENTS AND 6100 SPRINT PARKWAY AUTHORIZE CONTRACTOR TO PROCEED WITH THE CONSTRUCTION DESCRIBED OVERLAND PARK, KS 66251 HEREIN, ALL DOCUMENTS ARE SUBJECT TO REVIEW BY THE LOCAL BUILDING SITE NUMBER (479) 721-1383 DEPARTMENT AND MAY IMPOSE CHANGES OR MODIFICATIONS. (JOHNNY 501) 5741269 SITE ACCESS PROCEDURES ENGINEER'S LICENSE- 4-1269 SS SPRINT MARKED WITH BLACK & YELLOW TAPE COMBINATION LOCKS: 6985 SD 711 SOUTHH IZ R ARD STREET RF ENGINEER: ALL CABINET COMBINATION LOCKS: 6985 LITTLE ROCK, ARKANSAS 72201 raw SHEET TITLE FIBER PROVIDER: b11� TITLE SHEET cabdm ft POWER PROVIDER: SHEETNUMBER 1 (800) 482-8998 T-1 ABBREVIATIONS AFF ABOVE FINISHED FLOOR AGL ABOVE GRADE LEVEL AMSL ABOVE MAIN SFA LEVEL APPROX APPROXIMATE AWG AMERICAN WIRE GAUGE BLDG BUILDING BTS BASE TRANSMISSION STATION CUR CLEAR COL COLUMN CONIC CONCRETE CND CONDUIT DWG DRAWING FT FOOT (FEET) EGB EQUIPMENT GROUND BAR ELEC ELECTRICAL EMT ELECTRICAL METALLIC TUBING ELEV ELEVATION EQUIP EQUIPMENT (E) EXISTING EXT EXTERIOR FND FOUNDATION F FIBER GA GAUGE GALV GALVANIZED GPS GLOBAL POSITIONING SYSTEM GND GROUND LTE LONG TERM EVOLUTION MAX MAXIMUM MFR MANUFACTURER MGB MASTER GROUND BAR MIN MINIMUM MMBTS MULTI—NODE BASE TRANSMISSION STATION N.T.S. NOT TO SCALE O.C. ON CENTER OE/OT OVERHEAD ELECTRIC/TELCO PPC POWER PROTECTION CABINET RBS RADIO BASED STATION RRU REMOTE RADIO UNIT RGS RIGID GALVANIZED STEEL IN INCH(ES) INT INTERIOR LB(S) POUND(S) SF SQUARE FOOT STL STEEL TYP TYPICAL UE/UT UNDERGROUND ELECTRIC/TELCO LINO UNLESS NOTED OTHERWISE VIF VERIFY IN FIELD W/ WITH XFMR TRANSFORMER # POUND(S) SYMBOLS CALL BEFORE YOU DIG - DRILL - BLAST 1-800-482-8998 (TOLL FREE) ARKANSAS ONE -CALL SYSTEM. INC. THE UTILITIES AS SHOWN ON THIS SET OF DRAWINGS WERE DEVELOPED FROM THE INFORMATION AVAILABLE. THE INFORMATION PROVIDED iS NOT IMPLIED NOR INTENDEO TO BE THE COMPLETE INVENTORY OF UTILITIES IN THIS AREA IT IS THE CONTRACTOR'S RESPONSIBILITY TO VERIFY THE LOCATION OF ALL UTILITIES (WHETHER SHOWN OR NOT) AND PROTECT SAID UTILITIES FROM ANY DAMAGE CAUSED BY CONTRACTOR'S ACTIVITIES. SITE PLAN C O Z� ! .I SEE SHT FOR EQUIPMENTT LAYOUTS AYOUTS E I CONTRACTOR SHALL REPAIR EXISTING GRAVEL SURFACES DISTURBED DURING CONSTRUCTION WITH 2' THICK CLEAN CRUSHED STONE OVER 4' THICK COMPACTED AGGREGATE BASE, REPLACE UNDERLYING GEOTE)MLE FABRIC AS REQUIRED O' 1' 2' 3' 4' Ta' 12' Sprint ')p'I' 6560 SPRINT PARKWAY OVERLAND PARK, KANSAS 86251 409 0 ERICSSON 6100 SPRINT PARKWAY OVERLAND PARK, KANSAS 66251 SSC 9900 West 109th Street, Suite 300 Ovedand Park, Kansas 66210 Phone: 913438-7700 Fa 913436-7777 STATE OF ARKANSAS CERTIFICATE OF AUTHORIZATION #774 RESPONSIBLE ENGINEERS: MLO MICHAEL OWENS 13458 STRUCTURALICNIL TMS TERRANCEM SUPER 9717 ELECTRICAL NOTICE THIS DRAWING HAS NOT BEEN PUBLISHED AND IS THE SOLE PROPERTY OF SSC, INC. AND IS LENT TO THE BORROWER FOR THEIR CONFIDENTIAL USE ONLY, AND IN CONSIDERATION OF THE LOAN OF THIS DRAWING, THE BORROWER PROMISES AND AGREES TO RETURN IT UPON REQUEST AND AGREES THAT IT WILL NOT BE REPRODUCED, COPIED, LENT OR OTHERWISE DISPOSED OF DIRECTLY OR INDIRECTLY, NOR USED FOR ANY PURPOSE OTHER THAN FOR WHICH IT IS FURNISHED. DESIGNER: T.N. TAYLOR LEAD EE: T. SUPER LEAD CENSE: M. OWENS SUBMITTALS NO. DATE DESCRIPTION BY A 10/79�f2 FOR REMN RIT SITE NAME DOWNTOWN WEST SITE NUMBER LR03XC001 SITE ADDRESS 711 SOUTH IZARD STREET LITTLE ROCK, ARKANSAS 72201 SHEET TITLE ENLARGED SITE PLAN SHEET NUMBER A-1 REVISION WORK POINT 0 UTILITY POLE ® WALL COMPRESSED STONE CONCRETE/GRAVEL ASPHALT EARTH GRATING STEEL - CENTERUNE - - PROPERTY LINE ------- LEASE LINE - - - - - EASEMENT LINE -.-.-.- CHAIN LINK FENCE -T�Tr WOOD FENCE BELOW GRADE --------- ELECTRIC BELOW GRADE TELEPHONE -OHP-OHP- OVERHEAD ELECTRIC/TELEPHONE �i Al SECTION REFERENCE CALL BEFORE YOU DIG - DRILL - BLAST 1-800-482-8998 (TOLL FREE) ARKANSAS ONE -CALL SYSTEM. INC. THE UTILITIES AS SHOWN ON THIS SET OF DRAWINGS WERE DEVELOPED FROM THE INFORMATION AVAILABLE. THE INFORMATION PROVIDED iS NOT IMPLIED NOR INTENDEO TO BE THE COMPLETE INVENTORY OF UTILITIES IN THIS AREA IT IS THE CONTRACTOR'S RESPONSIBILITY TO VERIFY THE LOCATION OF ALL UTILITIES (WHETHER SHOWN OR NOT) AND PROTECT SAID UTILITIES FROM ANY DAMAGE CAUSED BY CONTRACTOR'S ACTIVITIES. SITE PLAN C O Z� ! .I SEE SHT FOR EQUIPMENTT LAYOUTS AYOUTS E I CONTRACTOR SHALL REPAIR EXISTING GRAVEL SURFACES DISTURBED DURING CONSTRUCTION WITH 2' THICK CLEAN CRUSHED STONE OVER 4' THICK COMPACTED AGGREGATE BASE, REPLACE UNDERLYING GEOTE)MLE FABRIC AS REQUIRED O' 1' 2' 3' 4' Ta' 12' Sprint ')p'I' 6560 SPRINT PARKWAY OVERLAND PARK, KANSAS 86251 409 0 ERICSSON 6100 SPRINT PARKWAY OVERLAND PARK, KANSAS 66251 SSC 9900 West 109th Street, Suite 300 Ovedand Park, Kansas 66210 Phone: 913438-7700 Fa 913436-7777 STATE OF ARKANSAS CERTIFICATE OF AUTHORIZATION #774 RESPONSIBLE ENGINEERS: MLO MICHAEL OWENS 13458 STRUCTURALICNIL TMS TERRANCEM SUPER 9717 ELECTRICAL NOTICE THIS DRAWING HAS NOT BEEN PUBLISHED AND IS THE SOLE PROPERTY OF SSC, INC. AND IS LENT TO THE BORROWER FOR THEIR CONFIDENTIAL USE ONLY, AND IN CONSIDERATION OF THE LOAN OF THIS DRAWING, THE BORROWER PROMISES AND AGREES TO RETURN IT UPON REQUEST AND AGREES THAT IT WILL NOT BE REPRODUCED, COPIED, LENT OR OTHERWISE DISPOSED OF DIRECTLY OR INDIRECTLY, NOR USED FOR ANY PURPOSE OTHER THAN FOR WHICH IT IS FURNISHED. DESIGNER: T.N. TAYLOR LEAD EE: T. SUPER LEAD CENSE: M. OWENS SUBMITTALS NO. DATE DESCRIPTION BY A 10/79�f2 FOR REMN RIT SITE NAME DOWNTOWN WEST SITE NUMBER LR03XC001 SITE ADDRESS 711 SOUTH IZARD STREET LITTLE ROCK, ARKANSAS 72201 SHEET TITLE ENLARGED SITE PLAN SHEET NUMBER A-1 SSC FAS NOT PERFORMED A STRUCTURAL TOWER ANALYSIS AND HAS NOT BEEN PROVIDED ANY STRUCTURAL TOWER ANALYSIS INFORMATION REGARDING THIS SITE. (Fl FYICTINr SPRINT SITE ELEVATION POSED SPRINT ANTENNAS PROPOSED SPRINT CABINETS ON EXISTING STEEL PLATFORM 1, THE SIZE, HEIGHT, AND DIRECTION OF THE ANTENNA SHALL BE AOJUSTIOJ TO MEET SYSTEM REQUIREMENTS. 2. CONTRACTOR SHALL VERIFY HEIGHT OF ANTENNA WITH ERICSSON REPRESENTATIVE. 3. ALL ANTENNA AZIMUTHS TO BE TAKEN FROM TRUE NORTH. PENDING ANTENNA MOUNT CERTIFICATION SITE HAS EXISTING RF SIGNAGE NOTES: 1. CONTRACTOR TO FIELD VERIFY ANTENNA CABLE LENGTHS. 2. ALL MAIN CABLES WILL BE COLOR CODED AT THREE (3) LOCATIONS. 3. COLOR CODE ALL ANTENNA AND COAX WITH 2' WIDE BANDS OF COLORED TAPE WITH 1' SEPARATION BETWEEN BANDS — SEE SHEET A-7. 4. COLOR CODE ALL TOP AND BOTTOM GROUND KITS WITH 1' WIDE BANDS OF COLORED TAPE WITH 1/2' SEPARATION BETWEEN BANDS. 5. START COLOR BANDS 2' BEYOND WEATHERPROOFING. 6. START SECTOR COLOR NEXT TO ENO CONNECTOR. 7. ALL MAIN CABLES WILL BE GROUNDED W/ COAXIAL CABLE GROUND KITS AT: • THE ANTENNA LEVEL • MID LEVEL IF TOWER IS OVER 200' • BASE OF TOWER PRIOR TO TURNING HORIZONTAL • TERMINATION OF COAX LINES TO JUMPERS 6. ALL NEW GROUND BAR DOWNLEADS ARE TO BE CADWELDED TO THE EXISTING ADJACENT GROUND BAR DOWNLEADS A MINIMUM DISTANCE OF 4' BELOW GROUND BAR, 9. PROVIDE BUSS BAR NEAR BTS FOR ATTACHMENT OF WiMAX COAX GROUND KITS. COAXIAL AN CABLE INN T 1. THE ANTENNA COAXIAL STALLER SHALL BE RESPONSIBLE FOR PERFORMING AND SUPPLYING SPRINT WITH 3 TYPEWRITTEN SWEEP TESTS (ANTENNA RETURN LOSS TEST). THIS TEST SHALL BE PERFORMED TO THE SPECIFICATIONS AND PARAMETERS OUTLINED BY THE SPRINT RADIO FREQUENCY (RF) ENGINEER. THIS TEST SHALL BE PERFORMED PRIOR TO FINAL ACCEPTANCE OF THE SITE. 2. THE ANTENNA COAXIAL CABLE INSTALLER SHALL BE RESPONSIBLE FOR PERFORMING AND SUPPLYING SPRINT WITH 3 TYPEWRITTEN TIME DOMAIN REFLECTOMETER (TDR) TESTS TO VERIFY CABLE LENGTH AND TO CHECK FOR WATER DAMAGE. 3. VAPOR WRAP WILL BE USED TO SEAL ALL CONNECTIONS. 4. ALL JUMPERS TO THE ANTENNAS FROM THE MAIN TRANSMISSION LINE WILL BE 1/2' JUMPERS AT WTMAX BTS UNITS WILL BE 6'-»0'. 5. IF COAX IS BEING RE—USED FOR THIS INSTALLATION, PRE AND POST ANTENNA LINE SWEEPS ARE REQUIRED. 6. UPON COMPLETION, PROVIDE A HEIGHT VERIFICATION DEPICTING RAD CENTER AND TOP OF ANTENNA. 1. DESIGN AND CONSTRUCTION OF ANTENNA SUPPORTS SHALL CONFORM TO CURRENT ANSI/EIA/TIA-222; APPENDIX B FOR WIND LOADING; 'STRUCTURAL STANDARDS FOR STEEL ANTENNA TOWERS AND ANTENNA SUPPORTING STRUCTURES' OR APPLICABLE LOCAL CODES. 2. ALL STEEL MATERIALS SHALL BE GALVANIZED AFTER FABRICATION IN ACCORDANCE WITH ASTM A123 'ZINC (HOT—DIPPED GALVANIZED) COATINGS ON IRON AND STEEL PRODUCTS', UNLESS OTHERWISE NOTED. 3. ALL BOLTS, ANCHORS AND MISCELIJWEOUS HARDWARE SHALL BE GALVANIZED IN ACCORDANCE WITH ASTM A153 'ZINC (HOT—DIP) ON IRON AND STEEL HARDWARE', UNLESS OTHERWISE NOTED. 4. DAMAGED GALVANIZED SURFACES SHALL BE REPAIRS BY COLD GALVANIZING IN ACCORDANCE WITH ASTM A780. 5. ALL ANTENNA MOUNTS SHALL BE INSTALLED WITH DOUBLE NUTS AND SHALL BE INSTALLED SNUG TIGHT 6. MINIMUM HORIZONTAL PACING SHALL BE 2'-0' BETWEEN ALL ANTENNAS. SITE ELEVATION Sprint '),� 6560 SPRINT PARKWAY OVERLAND PARK, KANSAS 66251 RE pp ERICSSON 6100 SPRINT PARKWAY OVERLAND PARK KANSAS 56251 ssc9900 west 10u Ovedand Park, Kansas 66210 Phone: 913-436-700 Far, 913-438-777 STATE OF ARKANSAS CERTIFICATE OF AUTHORIZATION #774 RESPONSIBLE ENGINEERS: MLO MICHAEL OWENS 13458 STRUCTURALICIVIL TMS TERRANCEM SUPER 9717 ELECTRICAL NOTICE THIS DRAWING HAS NOT BEEN PUBLISHED AND IS THE SOLE PROPERTY OF SSC, INC AND IS LENT TO THE BORROWER FOR THEIR CONFIDENTIAL USE ONLY, AND IN CONSIDERATION OF THE LOAN OF THIS DRAWING, THE BOMCO VER MIM SES AND AGREES TO RETURN IT UPON REQUEST AKD AGREES THAT IT WILL NOT BE REPRODUCED, COPIED, LENT OR OTHERWISE DISPOSED OF DIRECTLY OR INDIRECTLY, NOR USED FOR ANY PURPOSE OTHER THAN FOR WHICH IT IS FURNISHED DESIGNER: T.N TAYLOR LEAD EE: T. SUPER LEAD CENSE: M OWENS SUBMITTALS NO. DATE DESCRIPTION BY A 16/27/12 WO FOR RcE&V TNT SITE NAME DOWNTOWN WEST SITE NUMBER LR03XCOOI SITE ADDRESS 711 SOUTH IZARD STREET LITTLE ROCK, ARKANSAS 72201 SHEET TITLE SITE ELEVATION SHEET NUMBER A-2 EXISTING PPC RACK 85' LE EXISTING 10'X20' y' LEASE AREA EXISTING ICE BRIDGE 0 [EXISTING GPS o I I c (3) EXISTING SPRINT CABINETS EXISTING WOODEN FENCE r 11 4" 13'-6' 2 _1• 0' 1' 2' 4• 6' B' C NCRETE PAD - EXISTING EQUIPMENT LAYOUT EXISTING 85' MONOPOLE (3) EXISTING RELOCATED SPRINT CABINETS TO BE TO BE REMOVED AFTER NEW CABINET INSTALLATION HAS BEEN TESTED AND APPROVED BY PROJECT MANAGER TEMPORARY EQUIPMENT LAYOUT EXISTING 85' MONOPOLE EXISTING ICE BRIDGE'. r� 4' 6'-2. EXISTING V -4 - EXISTING PROPOSED RBS CABINET PROPOSED BBS CABINET ICE BRIDGE 1 PROPOSED GPS 6'-2' EXISTING EXISTING GPS o PROPOSED RBS CABINET PROPOSED BBS CABINET PPC RACK (3) EXISTING RELOCATED SPRINT CABINETS TO BE TO BE REMOVED AFTER NEW CABINET INSTALLATION HAS BEEN TESTED AND APPROVED BY PROJECT MANAGER TEMPORARY EQUIPMENT LAYOUT EXISTING 85' MONOPOLE EXISTING ICE BRIDGE'. r� 4' 6'-2. ` V -4 - EXISTING PROPOSED RBS CABINET PROPOSED BBS CABINET PPC RACK 1 PROPOSED GPS 16'-0' (CoWREM PAD) FINAL EQUIPMENT LAYOUT WOODEN FENCE 0' 1' 2' 4' 6' 6' e' 1 WOODEN FENCE 0' 1' 2' 4' 6' e' Sprint )1� 6560 SPRINT PARKWAY OVERLAID PARK, KANSAS 66251 w ooP PIP ERI CSSON 6100 SPRINT PARKWAY OVERLAND PARK, KANSAS 66251 SSC 9900 West 1091h Street, Suite 300 Overland Palk, Kansas 66210 Phone: 913436-7700 Fax: 91348-7777 STATE OF ARKANSAS CERTIFICATE OF AUTHORIZATION #774 RESPON&BLE "'r""EP[S MLO MICHAEL OWENS 13456 STRUCTURAVCML TMS TERRANCE M SUPER 9717 ELECTRICAL NOTICE: MIS OROeMNG HAS NOT BEEN PLBLISHEO µDIS THE SOLE PROPERTY OF SSC, INC -AND IS LENT TO THE BORRO WER FOR THEIR CONFIDENTIAL USE ONLY, AND IN CONSIDERATION OF THE LOAN OF THIS DR.NMIY , THE SOMOWER PROMISES AND AGREES TO= R L&ON %DDU.EST MID AOREES THAT IT WI.I.1407 BEUCEO, COPIED, LENT OR OTHERNI6E DISPOSED OF O`RsCTLY OR INDLREC TLY, NOR USW FORAM/ PURPOSE OTHER THAN FOR WHICH IT IS FURNISHED DESIGNER: T.N TAYLOR LEAD EE: T SUPER LEAD CENSE: M OWENS SUBMITTALS NO. DATE DESCRIPTION BY A RM77/:# M FOR MU TNT SITE NAME DOWNTOWN WEST SITE NUMBER LR03XCO01 SITE ADDRESS 711 SOUTH IZARD STREET LITTLE ROCK, ARKANSAS 72201 SHEET TITLE EQUIPMENT LAYOUTS SHEET NUMBER A-3 :NNAS TO LETION SECTOR: 3 PROPOSED SPR­ PRAZIMUTH: 300' INT ANTENNA AND MOUNTING HARDWARE (TYP OF 3) G PLATFORM do, e00M EXISTING ANTENNA LAYOUT EXISTING MONOPOLE NEW CABLES ROUTED UP EXISTING SELF-SUPPORT TOWER (TYP) EXISTING ICE BRIDGE O' 6" 1' 2' 3' 4' w 0 I I 1 1 I 1 i (3) NEW HYBRID TOWER CABLES FROM REAR OF CABINET ROUTED ON EXISTING CABLE BRIDGE (1) SHOWN FOR CLARITY CABLES ATTACHED TO EXISTING SUPPORTS WITH ROSENBERGER GROMMET HANGER KIT PART# CS624-TH415 COAX RUN DIAGRAM EXISTING EQUIPMENT CONCRETE PAD a *'* �ollllllcll /") � , SECTOR! 2 AZIMUTH: 200' a _O7 o� TEMPORARY ANTENNA LAYOUT (6) EXISTING SPRINT ANTENNAS TO BE REMOVED UPON COMPLETION OF EQUIPMENT MIGRATION 800/1900 SECTOR: 1 AZIMUTH: 60 PROPOSED SPRINT RRU'S ON PROPOSED PIPE MOUNT (TYPICAL 3 PLACES) O SECTOR: 2 AZIMUTH: 200' o � FINAL ANTENNA LAYOUT SECTOR: 1 AZIMUTH: 60 ) SPRINT RRU'S OSED PIPE MOUNT 3 PLACES) 0' 6' 1, 2' 3' 4' 2 Sprint '),� 6560 SPRINT PARKWAY OVERLAND PARK, KANSAS 66251 409 Pol po ERICSSON 6100 SPRINT PARKWAY 0YERIAND PARK, KANSAS 66251 N�, SSC 9900 Wes[ 109Th Street Suite 300 Overland Park, Kansas 66210 Phone: 913-438-7700 Fax: 913-03&7777 STATE OF ARKANSAS CERTIFICATE OF AUTHORIZATION #774 RESPONSIBLE ENGINEERS: MLO MICHAELLOWENS 13459 STRUCTURAL/CIVIL TMS TERRANCE M SUPER 9717 ELECTRICAL NOTICE: TttS ORASNNO HAS NOT BEEN PUBLISHED AND IS THE SOLE PROPERTY OF SSC, INC. AND IS LENT TO THE BORROWER FOR THEIR CONFIDENTIAL USE ONLY, AND IN CONSIDERATION OF THE LOAN OF THIS DRAWING, THE BORROWER PROMISES AND AGREES TO RETURN IT UPON REQUEST AND AGREES THAT IT WILL NOT BE REPRODUCED, COPIED, LENT OR OTHERWISE DISPOSED OF DIRECTLY OR INDIRECTLY, NOR USED FOR ANY PURPOSE OTHER THAN FOR WHICH IT IS FURNISHED DESIGNER: T.N TAYLOR LEAD EE: T SUPER LEAD CENSE: M OWENS SUBMITTALS WE DATE DESCRIPTION BY A 1 2 ISM FOR fEM TNT SITE NAME DOWNTOWN WEST SITE NUMBER LR03XCO01 SITE ADDRESS 711 SOUTH IZARD STREET LITTLE ROCK, ARKANSAS 72201 SHEET TITLE ANTENNA PLANS SHEET NUMBER A-4 NOTE: FINAL RRU LOCATION k NOTE MOUNTING PENDING STIR 1. EXACT ROUTING OF CABLES TO BE REVIEW AND RF APPRO\ DETERMINED BY STRUCTURAL ANALYSIS (BY OTHERS) 2. NEW GPS ANTENNA TO BE AT LEAST 4' FROM EXISTING GPS ANTENNAS PROPOSED SPRINT ANTENNA AND MOUNTIN HARDWARE (TYP OF 3) NEW CABINETS ON EXISTING EQUIPMENT PLATFORM M i (3) NEW HYBRID TOWER CABLES FROM REAR OF CABINET ROUTED ON EXISTING CABLE BRIDGE (1) SHOWN FOR CLARITY CABLES ATTACHED TO EXISTING SUPPORTS WITH ROSENBERGER GROMMET HANGER KIT PART# CS624-TH415 COAX RUN DIAGRAM EXISTING EQUIPMENT CONCRETE PAD a *'* �ollllllcll /") � , SECTOR! 2 AZIMUTH: 200' a _O7 o� TEMPORARY ANTENNA LAYOUT (6) EXISTING SPRINT ANTENNAS TO BE REMOVED UPON COMPLETION OF EQUIPMENT MIGRATION 800/1900 SECTOR: 1 AZIMUTH: 60 PROPOSED SPRINT RRU'S ON PROPOSED PIPE MOUNT (TYPICAL 3 PLACES) O SECTOR: 2 AZIMUTH: 200' o � FINAL ANTENNA LAYOUT SECTOR: 1 AZIMUTH: 60 ) SPRINT RRU'S OSED PIPE MOUNT 3 PLACES) 0' 6' 1, 2' 3' 4' 2 Sprint '),� 6560 SPRINT PARKWAY OVERLAND PARK, KANSAS 66251 409 Pol po ERICSSON 6100 SPRINT PARKWAY 0YERIAND PARK, KANSAS 66251 N�, SSC 9900 Wes[ 109Th Street Suite 300 Overland Park, Kansas 66210 Phone: 913-438-7700 Fax: 913-03&7777 STATE OF ARKANSAS CERTIFICATE OF AUTHORIZATION #774 RESPONSIBLE ENGINEERS: MLO MICHAELLOWENS 13459 STRUCTURAL/CIVIL TMS TERRANCE M SUPER 9717 ELECTRICAL NOTICE: TttS ORASNNO HAS NOT BEEN PUBLISHED AND IS THE SOLE PROPERTY OF SSC, INC. AND IS LENT TO THE BORROWER FOR THEIR CONFIDENTIAL USE ONLY, AND IN CONSIDERATION OF THE LOAN OF THIS DRAWING, THE BORROWER PROMISES AND AGREES TO RETURN IT UPON REQUEST AND AGREES THAT IT WILL NOT BE REPRODUCED, COPIED, LENT OR OTHERWISE DISPOSED OF DIRECTLY OR INDIRECTLY, NOR USED FOR ANY PURPOSE OTHER THAN FOR WHICH IT IS FURNISHED DESIGNER: T.N TAYLOR LEAD EE: T SUPER LEAD CENSE: M OWENS SUBMITTALS WE DATE DESCRIPTION BY A 1 2 ISM FOR fEM TNT SITE NAME DOWNTOWN WEST SITE NUMBER LR03XCO01 SITE ADDRESS 711 SOUTH IZARD STREET LITTLE ROCK, ARKANSAS 72201 SHEET TITLE ANTENNA PLANS SHEET NUMBER A-4