HomeMy WebLinkAboutZ-7218-A Staff AnalysisFILE NO.: Z -7218-A
NAME: Boyle Building Short -form PCD
LOCATION: Located at 500 South Main Street
DEVELOPER:
Chi Hotel Group LLC
12206 West Markham Street
Little Rock, AR 72211
SURVEYOR:
Paul Fleming
18 Essay Drive
Little Rock, AR 72223
AREA: 0.193 -acres NUMBER OF LOTS: 1 FT. NEW STREET: 0 LF
WARD: 1 PLANNING DISTRICT: 5 - Downtown CENSUS TRACT: 44
CURRENT ZONING: UU, Urban Use District
ALLOWED USES: Uses as allowed in the Residential, Office, Commercial and Industrial
zoning districts — all indoor uses.
PROPOSED ZONING: PCD
PROPOSED USE: UU, Urban Use District uses and allow multi -family at a density
greater than currently allowed in the UU, Urban Use Zoning District.
VARIANCElWAIVERS: None requested.
A. PROP 0SALIREQUEST/AP PLICANT'S STATEMENT:
The applicant is requesting a rezoning of the site from UU, Urban Use District to
PCD, Planned Commercial Development District, to allow the redevelopment of
the Boyle Building as a mixed use development. The applicant has indicated the
development will potentially include multi -family at a density greater than currently
allowed in the UU, Urban Use Zoning District.
Fl LE NO.- Z -7218-A Cont.
According to the applicant the building is currently vacant and awaiting
revitalization. The planned uses of the Boyle Building include hotel, office,
commercial tenants on the ground floor of the structure, and up to 96 apartments.
The building will be repurposed and revitalized in a single phase.
B. EXISTING CONDITIONS:
Renovations on the building have begun but appear to have stopped. The buiiding
is a multi -story building (12 -stories) built in 1909. This area of Main Street is
currently under significant renovation and redevelopment. The Little Rock
Technology Park is located to the east of the site on the northeast corner of Capitol
Avenue and Main Street and State of Arkansas owned property is located on the
southeast corner of Capitol Avenue and Main Street. North of the site, across
Capitol Avenue is a surface parking lot. West of the site are office buildings and
uses.
C. NEIGHBORHOOD COMMENTS:
All property owners located within 200 -feet of the site along with the Downtown
Neighborhood Association and the MacArthur Park Property Owners Association
were notified of the public hearing.
D. ENGINEERING COMMENTS:
PUBLIC WORKS CONDITIONS:
1. Repair or replace any curb and gutter or sidewalk that is damaged in the public
right-of-way prior to occupancy.
E. UTILITIES AND FIRE DEPARTMENTICOUNTY PLANNING:
Little Rock Water Reclamation Authorit : Sewer available to this site. Capacity
fee analysis required. EAD approval required for food service on site. Contact
Little Rock Water Reclamation Authority for additional information.
Enter : Entergy does not object to this proposal. A developer has already been
in contact with Entergy regarding service and preliminary requirements have been
discussed. Service is already being provided to the property via an electrical
network vault contained in the building. Contact Entergy in advance to discuss
any changes to electrical service requirements, or adjustments to existing facilities
(if any) as this proposal proceeds.
Centerpoint Energy: No comment received.
AT & T: No comment received.
i►
FILE NO.: Z -7218-A (Cont.
Central Arkansas Water:
1. All Central Arkansas Water requirements in effect at the time of request for
water service must be met.
2. The Little Rock Fire Department needs to evaluate this site to determine
whether additional public and/or private fire hydrant(s) will be required.
If additional fire hydrant(s) are required, they will be installed at the Developer's
expense.
3. Please submit plans for water facilities and/or fire protection system to Central
Arkansas Water for review. Plan revisions may be required after additional
review. Contact Central Arkansas Water regarding procedures for installation
of water facilities and/or fire service. Approval of plans by the Arkansas
Department of Health Engineering Division and the Little Rock Fire Department
is required.
4. If there are facilities that need to be adjusted and/or relocated, contact Central
Arkansas Water. That work would be done at the expense of the developer.
5. Contact Central Arkansas Water regarding the size and location of the
water meter.
6. The facilities on-site will be private. When meters are planned off private lines,
private facilities shall be installed to Central Arkansas Water's materials and
construction specifications and installation will be inspected by an engineer,
licensed to practice in the State of Arkansas. Execution of a Customer Owned
Line Agreement is required.
7. Due to the nature of this facility, installation of an approved reduced pressure
zone backflow preventer assembly (RPZA) is required on the domestic water
service. This assembly must be installed prior to the first point of use. Central
Arkansas Water requires that upon installation of the RPZA, successful tests
of the assembly must be completed by a Certified Assembly Tester licensed by
the State of Arkansas and approved by Central Arkansas Water. The test
results must be sent to Central Arkansas Water's Cross Connection Section
within ten days of installation and annually thereafter. Contact the Cross
Connection Section at 501.377.1226 if you would like to discuss backflow
prevention requirements for this project.
8. Fire sprinkler systems which do not contain additives such as antifreeze shall
be isolated with a double detector check valve assembly. If additives are used,
a reduced pressure zone back flow preventer shall be required.
9. The development will have minor impact on the existing water distribution
system. Proposed water facilities will be sized to provide adequate pressure
and fire protection.
3
FILE NO.: Z -721 6-A (Cont.
Fire De artment:
1. Maintain Access'.
2. Fire Hydrants. Maintain fire apparatus access roads at fire hydrant locations
as per Appendix D of the 2012 Arkansas Fire Prevention Code Vol. 1 Section
D103.1 Access road width with a hydrant. Where a fire hydrant is located on a
fire apparatus access road, the minimum road width shall be 26 feet, exclusive
of shoulders.
3. Grade. Maintain fire apparatus access roads as per Appendix D of the 2012
Arkansas Fire Prevention Code Vol. 1 Section D103.2 Grade. Fire apparatus
access roads shall not exceed 10 percent in grade except as approved by the
fire chief.
4. Loading Maintain fire apparatus access road design as per Appendix D of the
2012 Arkansas Fire Prevention Code Vol. 1 Section D102.1 Access and
loading. Facilities, buildings or portions of buildings hereafter constructed shall
be accessible to fire department apparatus by way of an approved fire
apparatus access road with an asphalt, concrete or other approved driving
surface capable of supporting the imposed load of fire apparatus weighing at
least 75,000 pounds.
5. 30' Tall Buildings -Maintain aerial fire apparatus access roads as per Appendix
D of the 2012 Arkansas Fire Prevention Code Vol. 1 Section D105.1 — D105.4
a. D105.1 Where Required. Where the vertical distance between the
grade plane and the highest roof surface exceed 30', approved aerial
fire apparatus access roads shall be provided. For the purposes of
this section the highest roof surfaces shall be determined by
measurement to the eave of a pitched roof, the intersection of a roof
to the exterior wall, or the top of the parapet walls, whichever is
greater.
b. D105.2 Width. Aerial fire apparatus access roads shall have a
minimum unobstructed with of 26', exclusive of shoulders, in the
immediate vicinity of the building or portion thereof.
c. D105.3 Proximity to building. At least one of the required access
routes meeting this condition shall be located within a minimum of 15
feet and a maximum of 30 feet from the building, and shall be
positioned parallel to one entire side of the building. The side of the
building on which the aerial fire apparatus access road is positioned
shall be approved by the fire code official.
d. D105.4 Obstructions. Overhead utility and power lines shall not be
located over the aerial fire apparatus access road or between the
aerial fire apparatus road and the building. Other obstructions shall
be permitted to be places with the approval of the fire code official.
2
FILE NO_: Z -7218-A (Cont.
6. Dead Ends. Maintain fire apparatus access roads at dead end locations as per
Appendix D of the 2012 Arkansas Fire Prevention Code Vol. 1 Section D103.4
Dead Ends. Dead-end fire apparatus access roads in excess of 150 feet shall
be provided with width and turnaround provisions in accordance with Table
D103.4. Requirements for Dead-end fire apparatus access roads.
7. Gates. Maintain fire apparatus access road gates as per Appendix D of the
2012 Arkansas Fire Prevention Code Vol. 1 Section D103.5 Fire apparatus
access road gates. Gates securing the fire apparatus access roads shall
comply with all of the following criteria:
1. Minimum gate width shall be 20 feet.
2. Gates shall be of swinging or sliding type.
3. Construction of gates shall be of material that allow manual operation by
one person.
4. Gate components shall be maintained in an operable condition at all
times and replaces or repaired when defective.
5. Electric gates shall be equipped with a means of opening the gate by
fire department personnel for emergency access. Emergency opening
devices shall be approved by the fire code official.
6. Manual opening gates shall not be locked with a padlock or chain and
padlock unless they are capable of being opened by means of forcible
entry tools or when a key box containing the keys to the lock is installed
at the gate location.
7. Locking device specifications shall be submitted for approval \by the fire
code official
8. Electric gate operators, where provided, shall be listed in accordance
with UL 325.
9. Gates, intended for automatic operation shall be designed, constructed
and installed to comply with requirements of ASTM F 2200.
8. Multi -family Residential Developments - As per Appendix D, Section D106.1 of
the 2012 Arkansas Fire Prevention Code Vol. 1. Projects having more than
100 dwelling units. Multiple -family residential projects having more than
100 dwelling units shall be equipped throughout with two separate and
approved fire apparatus access roads.
a. Exception: Projects having up to 200 dwelling units may have a single
approved fire apparatus access road when all building, including
nonresidential occupancies are equipped throughout with approved
automatic sprinkler systems installed in accordance with Section 903.3.1.1
or 903.3.1.2.
b. As per Appendix D, Section D106.2 of the 2012 Arkansas Fire prevention
Code Vol. 1. Projects having more than 200 dwelling units. Multiple -family
residential projects having more than 200 dwelling units shall be provided
5
FILE NO.: Z -7218-A (Cont.
with two separate and approved fire apparatus access roads regardless of
whether they are equipped with an approved automatic sprinkler system.
9. Fire Hydrants. Locate Fire Hydrants as per Appendix C of the
2012 Arkansas Fire Prevention Code. Section C101 — C105, in conjunction with
Central Arkansas Water (Jason Lowder 501.377.1245) and the
Little Rock Fire Marshal's Office (Capt. Tony Rhodes 501.918.3757 or
Capt. John Hogue 501.918.3754). Number and Distribution of Fire Hydrants as
per Table C105.1.
Parks and Recreation: No comment received.
County Planning,: No comment.
Rack Region Metro: Location is served by METRO on multiple routes at the care
of the transit system. We support the rehabilitation of transit accessible housing
and jobs in the downtown core. We recommend the streetscape be modified to
create a more pedestrian friendly and accessible bus stop area to accommodate
our existing transit stop. Current data for the past E month period show
1300+ boards at this location which is significant.
F. ISSUES/TECHNICAL/DESIGN:
Building Code: Project is subject to full commercial plan review and approval prior
to issuance of a building permit. For information on submittal requirements and the
review process, contact a commercial plans examiner:
Curtis Richey at 501.371.4724; cricheyCoVittlerock,gov or
Mark Alderfer at 501.371.4875; malderfer [ittlerock. ov.
Planning Division: This request is located in Downtown Planning District. The Land
Use Plan shows Mixed Use Urban (MXU). The Mixed Use -Urban category
provides for a mix of residential, office and commercial uses not only in the same
block but also within the same structure. This category is intended for older "urban"
areas to allow dissimilar uses to exist, which support each other to create a vital
area. Development should reinforce the urban fabric creating a 24-hour activity
area. Using the Planned Zoning District or the Urban Use District, high and
moderate density developments that result in a vital (dense) pedestrian oriented
area are appropriate. The applicant has applied for rezoning from UU (Urban Use)
to PCD (Planned Commercial District) to allow UU, Urban Use District uses and to
allow Multi -family at a density greater than typically allow per UU (Urban use)
District.
Master Street Plan: North of the properties is West Capitol Avenue it is shown as
a local street on the Master Street Plan. East of the Property is South Main Street
and is it shown as a Minor Arterial on the Master Street Plan. The primary function
of a Local Street is to provide access to adjacent properties. Local Streets that are
0
FILE NO.: Z -7218-A
abutted by non-residential zoning/use or more intensive zoning than duplexes are
considered as "Commercial Streets". A Collector design standard is used for
Commercial Streets. A Minor Arterial provides connections to and through an
urban area and their primary function is to provide short distance travel within the
urbanized area. Entrances and exits should be limited to minimize negative effects
of traffic and pedestrians on South Main Street since it is a Minor Arterial. These
streets may require dedication of right-of-way and may require street
improvements for entrances and exits to the site.
Bicycle Plan: There is a Class III Bike Route shown on South Main Street. These
bike routes require no additional right-of-way, but either a sign or pavement
marking to identify and direct the route.
Landscape:
1. Site plan must comply with the Little Rock Zoning Ordinance, Section
36-342.1, U Urban Use District and the City's landscape and buffer ordinance
requirements.
2. In accordance with the UU zoning district street trees a minimum of three-inch
(3") caliper will be required. The trees shall be located a minimum of two (2)
feet off the back of a curb, placed thirty (30) feet on center and no closer than
thirty (30) feet to a street intersection. A water source shall also be provided.
The tree canopy shall be maintained at least eight (8) feet above the sidewalk.
A franchise agreement must be obtained from Little Rock Public Works to place
landscape materials in the public right-of-way.
3. The City Beautiful Commission recommends preserving as many existing trees
as feasible on this site. Credit toward fulfilling Landscape Ordinance
requirements can be given when preserving trees of six (6) inch caliper or
larger.
G. SUBDIVISION COMMITTEE COMMENT: (June 28, 2017)
Mr. Jacob Chi was present representing the request. Staff presented an overview
of the item stating there were additional items necessary to complete the review
process. Staff stated any balconies over the public rights of way would require a
franchise agreement. Staff stated street trees were required along Capitol Avenue.
Staff questioned if there would be a food store, less than 5,000 square feet, selling
beer and wine.
Public Works comments were addressed. Staff stated any broken curb, gutter or
sidewalk that was damaged in the public right of way was to be repaired prior to
the issuance of the certificate of occupancy.
Landscaping comments were addressed. Staff stated a water source within
75 -feet of the plant materials was required. Staff stated the tree canopy was to be
maintained at least eight (8) feet above the sidewalk. Staff stated the placement
of the trees in the right of way would require a franchise agreement with the City.
7
FILE NO.: Z -7218-A Cont.
Staff noted the comments from the various other departments and agencies. Staff
suggested the applicant contact the departments or agencies directly with any
questions or concerns. There were no more issues for discussion.
The Committee then forwarded the item to the full Commission for final action.
H. ANALYSIS:
The applicant submitted revised comments to staff addressing concerns raised at
the June 28, 2017, Subdivision Committee meeting. The applicant is requesting
to maintain the UU, Urban Use Zoning District uses as allowable uses for the
property. The applicant has indicated any potential restaurant user may have
outdoor dining within the public right of way and is requesting to utilize the right of
way for outdoor dining. The outdoor dining area would comply with the provision
of the UU, Urban Use Zoning District in that the number of seats in the outdoor
seating area will not exceed 50 percent of the seats within the eating place, bar or
lounge. The applicant has indicated the areas of outdoor dining will fully comply
with the ordinance requirements and will not obstruct pedestrian movement, fire
lanes or areas designated for access by the physically impaired. Fencing will be
placed around the outdoor dining areas as required by the State Alcohol Beverage
Control (ABC) rules and regulations. The request includes the allowance of
multi -family which may result in a density greater than allowed per the UU, Urban
Use Zoning District. The UU, Urban Use Zoning District allows for development of
multi -family at a density of 72 units per acre.
The applicant is seeking approval of a rezoning from UU, Urban Use District to
PCD, Planned Commercial Development District, for the Boyle Building located at
500 South Main Street. The site contains 0.19 -acre and is a 12 -story building with
91,000 square feet of floor area. The future uses of the first floors of the property
may be a combination of restaurant and/or commercial tenants. The applicant has
indicated the upper floors will be designed to allow commercial space, office space
or multi -family. The applicant has indicated the number of multi -family units has
not been determined. The applicant has indicated the desire would be for the
approved PCD to allow tenant amenities such as a gym, theater, conferencing
area, party rooms, and a proposed rooftop pool and gathering area for guest
should the multi -family development prove the need for such amenities.
Within the UU, Urban Use Zoning District no off-street parking is required. The
applicant has indicated lighting, will be placed so as to reflect away from adjacent
residential structures. The fixtures adjacent to the roadways will be designed to
minimize glare to the motoring public. Signage will comply with signage allowed
within the UU, Urban Use Zoning District. The applicant does not anticipate the
placement of ground signage with the redevelopment of the site.
Section 36-342.1 states objects shall not project from the building facade over the
public right of way except for awnings, balconies and signs as specified in Section
36-553. Awnings shall not project more than 5 -feet from the building fagade and
have a minimum clearance of 8 -feet above the sidewalk. Balconies over the public
FILE NO.: Z -7218-A (Cont.)
right of way shall have a minimum clearance of 9 -feet above the sidewalk. The
maximum projection shall be 4 -feet. The applicant has indicated a parte cochere
will be added and will project into the right of way. The element will not be attached
to the building but will be constructed to not compromise the architectural and
historical integrity of the building.
The plan includes the placement of a drive lane and a porte cochere within the
right of way along Capitol Avenue. The drive lane is proposed 12 -feet wide. The
applicant proposes to remove the existing trees along Capitol Avenue in order to
facilitate the construction and maintenance of the drive lane. The drive lane is
being requested in order to remove valet, parking, and other vehicular traffic from
Capitol Avenue to allow traffic to flow in front of the building and not impede traffic.
The applicant has indicated the porte cochere may also be utilized if the site is
developed entirely as multi -family. Prior to the issuance of a building permit the
applicant will need to secure approval from the various utility companies and Public
Works staff to ensure proper placement and adequate maneuverability can be
maintained.
Section 36-342.1 states street trees a minimum of three inch caliper shall be
required. The trees shall be located a minimum of 2 -feet off the back of curb and
30 -feet on center and no closer than 30 -feet to a street intersection with a water
source provided. Tree canopy shall be maintained at least 8 -feet above the
sidewalk. The City has recently completed a streetscape project in this area along
Main Street. The request is to eliminate the street trees along West Capitol to
allow the placement of the drop-off lane.
Staff is supportive of the request. The applicant is seeking approval of the PCD
zoning to allow flexibility for the future redevelopment of the site with a mixture of
uses including retail, which would allow for restaurant users, office and/or
multi -family. The request includes the allowance of an increase in the allowable
density of multi -family for the building should the demand for multi -family at the
greater density prove to be marketable. The applicant has indicated tenant
amenities such as roof top outdoor activities may be constructed should the future
tenants desire these amenities to be provided. To staff's knowledge there are no
remaining outstanding technical issues associated with the request. Staff feels the
rezoning request as proposed is appropriate.
I. STAFF RECOMMENDATION:
Staff recommends approval of the request subject to compliance with the
comments and conditions as outlined in paragraphs D, E and F of the agenda staff
report.
A franchise agreement will be required for any projections into or use of the public
right of way.
A
FILE NO.: Z-7218-A(Cont.)
PLANNING COMMISSION ACTION: (JULY 20, 2017)
The applicant was present. There were no registered objectors present. Staff presented
the item with a recommendation of approval of the request subject to compliance with the
comments and conditions as outlined in paragraphs D, E and F of the agenda staff report.
Staff stated a franchise agreement was required for any projections into or use of the
public right of way. There was no further discussion. The item was placed on the consent
agenda and approved as recommended by staff by a vote of 9 ayes, 0 noes and 2 absent.
10
ITEM NO.: 9,
NAME: Boyle Building Short -form PCD
LOCATION: located at 500 South Main Street
Planning Staff Comments:
Z -7218-A
1. Provide notification of the property owners located within 200 -feet of the site including the
certified abstract list, notice form with affidavit executed and proof of mailing. The notice
must be mailed no later than July 5, 2017. The Office of Planning and Development must
receive the proof of notice no later than July 14, 2017.
2. Lighting is to be placed so as to reflect away from adjacent residential structures. Fixtures
adjacent to roadways shall be of a design that minimizes glare to the motoring public.
3. All ground mounted mechanical systems and trash receptacles and pickup shall be
oriented away from a primary street side of the property and screened from the public
right of way. Ground mounted mechanical systems and trash receptacles shall be placed
adjacent to alleys if alleys are available.
4. Street trees a minimum of three inch caliper shall be required. The trees shall be located
a minimum of 2 -feet off the back of curb and 30 -feet on center and no closer than 30 -feet
to a street intersection with a water source provided. Tree canopy shall be maintained at
least 8 -feet above the sidewalk.
5. The ground level (street fronting) floor of nonresidential structures shall have a minimum
surface area of 60 percent transparent or window display.
6. Objects shall not project from the building fagade over the public right of way except for
awnings, balconies and signs as specified in Section 36-553. Awnings shall not project
more than 5 -feet from the building facade and have a minimum clearance of 8 -feet above
the sidewalk. Balconies over the public right of way shall have a minimum clearance of 9 -
feet above the sidewalk. The maximum projection shall be 4 -feet.
7. Building signage is allowed as permitted in institutional and office zones. On the street
level, the maximum area of signage may be doubled if at least 50 percent of the street
level office and retail space has direct access to the street. Ground signs are discouraged
but may be permitted as a variance.
8. Will the units be maintained or will the units/suites be sold as condo units?
9. Will there be space available for a food store under 5,000 square feet which may sell beer
or wine?
10. It appears the uses proposed are the uses allowed in the UU, Urban Use Zoning District.
The request is to allow an increase in the overall density of the residential from 72 units
per acre as allowed within the UU, Urban Use Zoning District.
VarianceA /Vaivers: None requested.
Public Works Conditions:
Repair or replace any curb and gutter or sidewalk that is damaged in the public right-of-
way prior to occupancy.
ITEM NO.: 9.
Utilities and Fire Department/County Planning:
Z -7218-A
Little Rock Wastewater: Sewer available to this site. Capacity fee analysis required. EAD
approval required for food service on site. Contact Little Rock Wastewater Utility for
additional information.
Entergy: Entergy does not object to this proposal. A developer has already been in contact
with Entergy regarding service and preliminary requirements have been discussed. Service is
already being provided to the property via an electrical network vault contained in the
building. Contact Entergy in advance to discuss any changes to electrical service
requirements, or adjustments to existing facilities (if any) as this proposal proceeds.
Centerpoint Energy: No comment received.
AT & T: No comment received.
Central Arkansas Water:
1. All Central Arkansas Water requirements in effect at the time of request for water service
must be met.
2. The Little Rock Fire Department needs to evaluate this site to determine whether
additional public and/or private fire hydrant(s) will be required. If additional fire hydrant(s)
are required, they will be installed at the Developer's expense.
3. Please submit plans for water facilities and/or fire protection system to Central Arkansas
Water for review. Plan revisions may be required after additional review. Contact Central
Arkansas Water regarding procedures for installation of water facilities and/or fire service.
Approval of plans by the Arkansas Department of Health Engineering Division and the
Little Rock Fire Department is required.
4. If there are facilities that need to be adjusted and/or relocated, contact Central Arkansas
Water. That work would be done at the expense of the developer.
5. Contact Central Arkansas Water regarding the size and location of the water meter.
6. The facilities on-site will be private. When meters are planned off private lines, private
facilities shall be installed to Central Arkansas Water's materials and construction
specifications and installation will be inspected by an engineer, licensed to practice in the
State of Arkansas. Execution of a Customer Owned Line Agreement is required.
7. Due to the nature of this facility, installation of an approved reduced pressure zone
backflow preventer assembly (RPZA) is required on the domestic water service. This
assembly must be installed prior to the first point of use. Central Arkansas Water requires
that upon installation of the RPZA, successful tests of the assembly must be completed by
a Certified Assembly Tester licensed by the State of Arkansas and approved by Central
Arkansas Water. The test results must be sent to Central Arkansas Water's Cross
Connection Section within ten days of installation and annually thereafter. Contact the
Cross Connection Section at 501.377.1226 if you would like to discuss backflow
prevention requirements for this project.
ITEM NO.: 9. Z -7218-A _
8. Fire sprinkler systems which do not contain additives such as antifreeze shall be isolated
with a double detector check valve assembly. If additives are used, a reduced pressure
zone back flow preventer shall be required.
9. The development will have minor impact on the existing water distribution system.
Proposed water facilities will be sized to provide adequate pressure and fire protection.
Fire Department:
1. Maintain Access:
2. Fire Hydrants. Maintain fire apparatus access roads at fire hydrant locations as per
Appendix D of the 2012 Arkansas Fire Prevention Code Vol. 1 Section D103.1 Access
road width with a hydrant. Where a fire hydrant is located on a fire apparatus access road,
the minimum road width shall be 26 feet, exclusive of shoulders.
3. Grade. Maintain fire apparatus access roads as per Appendix D of the 2012 Arkansas
Fire Prevention Code Vol. 1 Section D103.2 Grade. Fire apparatus access roads shall not
exceed 10 percent in grade except as approved by the fire chief.
4. Loading. Maintain fire apparatus access road design as per Appendix D of the 2012
Arkansas Fire Prevention Code Vol. 1 Section D102.1 Access and loading. Facilities,
buildings or portions of buildings hereafter constructed shall be accessible to fire
department apparatus by way of an approved fire apparatus access road with an asphalt,
concrete or other approved driving surface capable of supporting the imposed load of fire
apparatus weighing at least 75,000 pounds.
5. 30' Tall Buildin s - Maintain aerial fire apparatus access roads as per Appendix D of the
2012 Arkansas Fire Prevention Code Vol. 1 Section D105.1 — D105.4
a. D105.1 Where Required. Where the vertical distance between the grade plane
and the highest roof surface exceed 30', approved aerial fire apparatus access
roads shall be provided. For the purposes of this section the highest roof
surfaces shall be determined by measurement to the eave of a pitched roof, the
intersection of a roof to the exterior wall, or the top of the parapet walls,
whichever is greater.
b. D105.2 Width. Aerial fire apparatus access roads shall have a minimum
unobstructed with of 26', exclusive of shoulders, in the immediate vicinity of the
building or portion thereof.
c. D105.3 Proximity to building. At least one of the required access routes meeting
this condition shall be located within a minimum of 15 feet and a maximum of
30 feet from the building, and shall be positioned parallel to one entire side of
the building. The side of the building on which the aerial fire apparatus access
road is positioned shall be approved by the fire code official.
d. D105.4 Obstructions. Overhead utility and power lines shall not be located over
the aerial fire apparatus access road or between the aerial fire apparatus road
and the building. Other obstructions shall be permitted to be places with the
approval of the fire code official.
3
ITEM NO.: 9, Z -7218-A
6. Dead Eads. Maintain fire apparatus access roads at dead end locations as per Appendix
D of the 2012 Arkansas Fire Prevention Code Vol. 1 Section D103.4 Dead Ends. Dead-
end fire apparatus access roads in excess of 150 feet shall be provided with width and
turnaround provisions in accordance with Table D103.4. Requirements for Dead-end fire
apparatus access roads.
7. Gates. Maintain fire apparatus access road gates as per Appendix D of the 2012
Arkansas Fire Prevention Code Vol. 1 Section D103.5 Fire apparatus access road gates.
Gates securing the fire apparatus access roads shall comply with all of the following
criteria:
1. Minimum gate width shall be 20 feet.
2. Gates shall be of swinging or sliding type.
3. Construction of gates shall be of material that allow manual operation by one
person.
4. Gate components shall be maintained in an operable condition at all times and
replaces or repaired when defective.
5. Electric gates shall be equipped with a means of opening the gate by fire
department personnel for emergency access. Emergency opening devices shall be
approved by the fire code official.
6. Manual opening gates shall not be locked with a padlock or chain and padlock
unless they are capable of being opened by means of forcible entry tools or when a
key box containing the keys to the lock is installed at the gate location.
7. Locking device specifications shall be submitted for approval \by the fire code
official
8. Electric gate operators, where provided, shall be listed in accordance with UL 325.
9. Gates, intended for automatic operation shall be designed, constructed and
installed to comply with requirements of ASTM F 2200.
8. Multi -family Residential Developments - As per Appendix D, Section D106.1 of the 2012
Arkansas Fire Prevention Code Vol. 1. Projects having more than 100 dwelling units.
Multiple -family residential projects having more than 100 dwelling units shall be equipped
throughout with two separate and approved fire apparatus access roads.
a. Exception: Projects having up to 200 dwelling units may have a single approved fire
apparatus access road when all building, including nonresidential occupancies are
equipped throughout with approved automatic sprinkler systems installed in
accordance with Section 903.3.1.1 or 903.3.1.2.
b. As per Appendix D, Section D106.2 of the 2012 Arkansas Fire prevention Code Vol. 1.
Projects having more than 200 dwelling units. Multiple -family residential projects
having more than 200 dwelling units shall be provided with two separate and approved
fire apparatus access roads regardless of whether they are equipped with an approved
automatic sprinkler system.
9. Fire Hydrants. Locate Fire Hydrants as per Appendix C of the 2012 Arkansas Fire
Prevention Code. Section C101 — C105, in conjunction with Central Arkansas Water
(Jason Lowder 501.377.1245) and the Little Rock Fire Marshal's Office (Capt. Tony
ITEM NO.: 9,
Z -7218-A
Rhodes 501.918.3757 or Capt. John Hogue 501.918.3754). Number and Distribution of
Fire Hydrants as per Table C105.1.
Parks and Recreation: No comment received.
County Planning. No comment.
Rock Region Metro: Location is served by METRO on multiple routes at the core of the
transit system. We support the rehabilitation of transit accessible housing and jobs in the
downtown core. We recommend the streetscape be modified to create a more pedestrian
friendly and accessible bus stop area to accommodate our existing transit stop. Current data
for the past 6 month period show 1300+ boards at this location which is significant.
Buildinu Code: Project is subject to full commercial plan review and approval prior to
issuance of a building permit. For information on submittal requirements and the review
process, contact a commercial plans examiner: Curtis Richey at 501.371.4724;
crichey@liitlerock.gov or Mark Alderfer at 501.371.4875; maiderfer littlerock. ov.
Planning Division: This request is located in Downtown Planning District. The Land Use Plan
shows Mixed Use Urban (MXU). The Mixed Use -Urban category provides for a mix of
residential, office and commercial uses not only in the same block but also within the same
structure. This category is intended for older "urban" areas to allow dissimilar uses to exist,
which support each other to create a vital area. Development should reinforce the urban
fabric creating a 24-hour activity area. Using the Planned Zoning District or the Urban Use
District, high and moderate density developments that result in a vital (dense) pedestrian
oriented area are appropriate. The applicant has applied for rezoning from UU (Urban Use) to
PCD (Planned Commercial District) to allow UU, Urban Use District uses and to allow Multi-
family at a density greater than typically allow per UU (Urban use) District.
Master Street Plan: North of the properties is West Capitol Avenue it is shown as a local
street on the Master Street Plan. East of the Property is South Main Street and is it shown as
a Minor Arterial on the Master Street Plan. .The primary function of a Local Street is to
provide access to adjacent properties. Local Streets that are abutted by non-residential
zoning/use or more intensive zoning than duplexes are considered as "Commercial Streets".
A Collector design standard is used for Commercial Streets. A Minor Arterial provides
connections to and through an urban area and their primary function is to provide short
distance travel within the urbanized area. Entrances and exits should be limited to minimize
negative effects of traffic and pedestrians on South Main Street since it is a Minor Arterial.
These streets may require dedication of right-of-way and may require street improvements for
entrances and exits to the site.
ITEM NO.: 9.
Z -7218-A
Bicycle Plan: There is a Class III Bike Route shown on South Main Street. These bike routes
require no additional right-of-way, but either a sign or pavement marking to identify and direct
the route.
Landscape:
1. Site plan must comply with the Little Rock Zoning Ordinance, Section 36-342.1, UU Urban
Use District and the City's landscape and buffer ordinance requirements.
2. In accordance with the UU zoning district street trees a minimum of three-inch (3") caliper
will be required. The trees shall be located a minimum of two (2) feet off the back of a
curb, placed thirty (30) feet on center and no closer than thirty (30) feet to a street
intersection. A water source shall also be provided. The tree canopy shall be maintained
at least eight (8) feet above the sidewalk. A franchise agreement must be obtained from
Little Rock Public Works to place landscape materials in the public right-of-way.
3. The City Beautiful Commission recommends preserving as many existing trees as
feasible on this site. Credit toward fulfilling Landscape Ordinance requirements can be
given when preserving trees of six (6) inch caliper or larger.
Revised plat/plan Submit four (4) copies of a revised preliminary plat/plan (to include the
additional information as noted above) to staff on Wednesday, July 5, 2017.