Loading...
HomeMy WebLinkAboutHDC1997-001 APPLICATION_2S P E C 1 F =CAT I O N S FOR : 2s. S RE NOVAT = ON 5 1 0 EA S T 3 TH _ S TREE T L = TTL E ROCK , ARKAN SAS 2 9 NOVEMB ER 1 9 9 G TOM AND B E TH F O T= 5 O 1 8 COUNTRY CLUB B LVD L I TTL E ROCK _ ARKAN SAS SOHN DH = T E C T 1 7 0 0 S PR = NG L =TTL E ROCK , ARKAN SA S ( SO 1) 3 7 5— 4 2 4 9 TITLE INDEX INDEX OF DRAWINGS SPECIFICATIONS: SECTION 1A: SUPPLEMENTAL GENERAL CONDITIONS SECTION 3A: CONCRETE SECTION 4A: MASONRY -GENERAL SECTION 4B: BRICK WORK SECTION 4C: CONCRETE BLOCK SECTION 5A: METALS SECTION 6A: GENERAL CARPENTRY SECTION 6B: ROUGH CARPENTRY SECTION 6C: FINISH CARPENTRY SECTION 7A: INSULATION SECTION 7B: WATERPROOFING AND CAULKING SECTION 7C: SHEETMETAL SECTION 7E: COMPOSITION SHINGLE ROOF SECTION 8A: WOOD DOORS SECTION 8F: GLASS AND GLAZING SECTION 9A: PAINTING SECTION 9B: DRYWALL INTERIOR FINISH SECTION 15A: PLUMBING SECTION 15B: HEATING, VENTILATING & AIRCONDITIONING SECTION 16A: ELECTRICAL i 40 i r SHEET A-1: SHEET A-2: SHEET M-1: SHEET E-1: SECTION IA SUPPLEMENTAL GENERAL CONDITIONS A. SPECIAL NOTE: THE SUPPLEMENTAL GENERAL CONDITIONS AND THE SPECIFICATIONS BOUND HEREWITH SHALL BE SUBJECT TO ALL THE REQUIREMENTS OF THE STANDARD FORM A201 OF THE "GENERAL CONDITIONS OF THE CONTRACT" (LATEST EDITION) ISSUED BY THE AMERICAN INSTITUTE OF ARCHITECTS, 1735 NEW YORK AVENUE, NORTH WEST, WASHINGTON, D.C. 20006, EXCEPT THAT THESE SUPPLEMENTAL GENERAL CONDITIONS SHALL TAKE PRECEDENCE OVER AND MODIFY ANY PAGES OF STATEMENTS OF THE "GENERAL CONDITIONS OF THE CONGRACT," AND SHALL BE USED IN CONJUNCTION WITH THEM AS PART OF THE "CONTRACT DOCUMENTS." 2. DRAWINGS AND SPECIFICATIONS: THE CONTRACTOR SHALL DO NO WORK WITHOUT PROPER DRAWINGS OR INSTRUCTIONS. WHERE DISCREPANCIES OCCUR ON THE DRAWINGS, OR WHERE THERE IS CONFLICT BETWEEN DRAWINGS AND SPECIFICATIONS, THE CONTRACTOR SHALL IMMEDIATELY NOTIFY THE OWNER, AND SHALL NOT PROCEED WITH THAT PORTION OF THE WORK UNTIL CLARIFICATION BY THE OWNER HAS BEEN PROVIDED. DISCREPANCIES WHICH WILL AFFECT BID AMOUNTS SHALL BE CALLED TO THE OWNER'S ATTENTION IN TIME TO PERMIT THE ISSUANCE OF A CLARIFICATION BY ADDENDUM TO ALL BIDDERS. 3. SANITATION: THE GENERAL CONTRACTOR SHALL PROVIDE OR ARRANGE FOR ADEQUATE SANITARY FACILITIES FOR WORKMEN. HE SHALL POST NOTICES, TAKE SUCH PRECAUTIONS AS MAY BE REQUIRED, AND DO ANY CLEANING NECESSARY TO KEEP THE PREMISES IN SANITARY CONDITION. 4. MEASUREMENTS: BEFORE ORDERING ANY MATERIAL OR DOING ANY WORK, THE CONTRACTOR SHALL VERIFY ALL MEASUREMENTS AT THE BUILDING SITE AND SHALL BE RESPONSIBLE FOR CORRECTNESS OF SAME. NO EXTRA CHARGE OR COMPENSATION WILL BE ALLOWED ON ACCOUNT OF DIFFERENCE BETWEEN ACTUAL DIMENSIONS AND THE MEASUREMENTS INDICATED ON THE DRAWINGS, ANY DIFFERENCE WHICH MAY BE FOUND, SHALL BE SUBMITTED TO THE OWNER FOR CONSIDERATION BEFORE PROCEEDING WITH THE WORK. 5. VARIATIONS FROM MATERIALS SPECIFIED: MATERIALS OR PRODUCTS SPECIFIED BY NAME OF MANUFACTURER, BRAND, TRADE NAME, OR CATALOG REFERENCE SHALL BE THE BASIS OF THE BID AND FURNISHED UNDER THE CONTRACT. WHERE TWO (2) OR MORE MATERIALS ARE NAMED, THE CHOICE OF THESE SHALL BE OPTIONAL WITH THE CONTRACTOR. SHOULD THE CONTRACTOR WISH TO USE ANY MATERIALS OR PRODUCTS OTHER THAN THOSE SPECIFIED, HE SHALL, AS SOON AS PRACTICABLE, WITHIN THIRTY (30) DAYS AFTER AWARD OF THE CONTRACT, MAKE WRITTEN REQUEST TO THE OWNER FOR HIS APPROVAL, NAMING THE PROPOSED SUBSTITUTION AND STATING THE DIFFERENCE, IF ANY, IN THE CONTRACT PRICE FOR SUCH SUBSTITUTIONS SHOULD THEY BE ACCEPTED BY THE OWNER. NO SUBSTITUTIONS WILL BE CONSIDERED AFTER THIRTY DAYS AND NO SUBSTITUTIONS SHALL BE MADE WITHOUT APPROVAL OF THE OWNER. SHOULD A SUBSTITUTION BE ACCEPTABLE AND SHOULD THE SUBSTITUTE MATERIAL PROVE DEFECTIVE OR OTHERWISE UNSATISFACTORY FOR THE SERVICE INTENDED AND WITHIN THE GUARANTY PERIODS, THE CONTRACTOR SHALL REPLACE THIS MATERIAL OR EQUIPMENT WITH THE MATERIAL OR EQUIPMENT SPECIFIED BY NAME. SECTION 1A, PAGE 1 OF 4 6. INSURANCE: THE CONTRACTOR SHALL NOT COMMENCE WORK UNDER THIS CONTRACT UNTIL HE HAS OBTAINED ALL INSURANCE REQUIRED UNDER THIS ARTICLE AND SUCH INSURANCE HAS BEEN APPROVED BY THE OWNER. BEFORE STARTING WORK, THE CONTRACTOR SHALL FURNISH TO THE OWNER CERTIFICATES OF REQUIRED INSURANCE AS SET FORTH BELOW, TO BE IN FORCE THROUGHOUT THE LIFE OF THIS CONTRACT. A. WORKERS COMPENSATION INSURANCE: THE CONTRACTOR SHALL PROCURE AND MAINTAIN DURING THE TERM OF THE CONTRACT WORKERS COMPENSATION AND EMPLOYERS LIABILITY INSURANCE FOR ALL OF HIS EMPLOYEES IN ACCORDANCE WITH STATUTES OF THE STATE OF ARKANSAS. IN CASE ANY OCCUPATIONS ARE REQUIRED FOR THE EXECUTION OF WORK WHICH ARE NOT COVERED BY THE WORKERS COMPENSATION ACT OF THE STATE OF ARKANSAS, SUITABLE EMPLOYERS LIABILITY INSURANCE SHALL BE PROCURED AND MAINTAINED DURING THE TERM OF THE CONTRACT BY THE CONTRACTOR TO COVER WORKERS ENGAGED IN SUCH OCCUPATIONS. THE LIMIT OF LIABILITY UNDER THE EMPLOYERS LIABILITY SECTION OF THIS POLICY SHALL NOT BE LESS THAN $100,000. B. COMPREHENSIVE PUBLIC LIABILITY INSURANCE: THE CONTRACTOR SHALL PROCURE AND MAINTAIN DURING THE TERM OF THE CONTRACT A COMPREHENSIVE PUBLIC LIABILITY INSURANCE POLICY WITH LIMITS NOT LESS THAN $300,000 FOR PERSONAL INJURY AND $100/100,000 PROPERTY DAMAGE. THIS POLICY MUST INCLUDE PRODUCTS AND COMPLETED OPERATIONS AND MUST INCLUDE "CONTRACTURAL COVERAGE" TO COVER CONTRACTUAL INDEMNITY WHEREIN THE CONTRACTOR SHALL INDEMIFY AND HOLD HARMLESS THE OWNER AND THE ARCHITECT AND THEIR AGENTS AND EMPLOYEES FROM AND AGAINST ALL CLAIMS, DAIMAGES, LOSSED, AND EXPENSED INCLUDING ATTORNEY'S FEES ARISING OUT OF OR RESULTING FROM THE PERFORMANCE OF THE WORK, PROVIDED SUCH CLAIM,. DAMAGE, LOSS OR INJURY, SICKNESS, DISEASE OR DEATH, OR INJURY TO OR DESTRUCTION OF TANGIBLE PROPERTY (OTHER THAN THE WORK ITSELF), INCLUDING THE LOSS OF USE THEREFROM, AND IS CAUSED IN WHOLE OR IN PART BY ANY NEGLIGENT ACT OR OMISSION OF THE CONTRACTOR, ANY SUBCONTRACTOR, ANYONE DIRECTLY OR INDIRECTLY EMPLOYED BY ANY OF THEM OR ANYONE FOR WHOSE ACTS ANY OF THEM MAY BE LIABLE, REGARDLESS OF WHETHER OR NOT IT IS CAUSED IN PART BY A PARTY INDEMNIFIED HEREUNDER. C. OWNER'S PROTECTIVE LIABILITY INSURANCE: THE CONTRACTOR SHALL PROCURE AND MAINTAIN DURING THE TERM OF THIS CONTRACT, OWNERS'S PROTECTIVE LIABILITY INSURANCE WITH AN ENDORSEMENT TO THE POLICY, WITH LIMITS OF NOT LESS THAN $300,000 EACH OCCURANCE FOR BODILY INJURY AND LIMITS OF NOT LESS THAN $100/100,000 FOR PROPERTY DAMAGE LIABILITY. D. COMPREHENSIVE AUTOMOBILE LIABILITY INSURANCE: THE CONTRACTOR SHALL PROCURE AND MAINTAIN DURING THE TERM OF THE CONTRACT COMPREHENSIVE AUTOMOBILE LIABILITY INSURANCE INCLUDING NON -OWNERSHIP AND HIRED AUTOMOBILE LIABILITY WITH LIMITS NOT LESS THAN $100/300,000 BODILY INJURY AND $100,000 PROPERTY DAMAGE. E. BUILDER'S RISK INSURANCE: THE CONTRACTOR SHALL PURCHASE AND MAINTAIN DURING THE TERM OF THE CONTRACT A STANDARD BUILDERS'S RISK INSURNACE POLICY INCLUDING VAMDALISM & MALICIOUS MISCHIEF COVERAGE. THIS INSURANCE COVERAGE SHALL BE WRITTEN IN THE NAME OF THE CONTRACTOR AND THE OWNER IN AN AMOUNT EQUAL TO 100% OF THE CONTRACT PRICE. THE SECTION 1A, PAGE 2 OF 4 ORIGINAL OF SAID POLICY SHALL BE DELIVER TO THE CONTRACTOR AND DUPLICATES SHALL BE FURNISHED TO THE OWNER. 7. EXTRA WORK: WITHOUT INVALIDATION THE CONTRACT, THE OWNER MAY ORDER EXTRA WORK OR MAKE ALTERATIONS, ADDING TO OR DEDUCTING FROM THE WORK, THE CONTRACT SUM BEING ADJUSTED ACCORDINGLY. ALL THE WORK OF THE KIND BID UPON SHALL BE PAID FOR AT THE PRICE STIPULATED IN THE PROPOSAL, AND NO CLAIMS FOR EXTRA WORK OR MATERIALS SHALL BE ALLOWED UNLESS SUCH EXTRA WORK IS ORDERED IN WRITING BY THE OWNER, WITH COSTS AGREED UPON CLEARLY STATED THEREIN, AND NO BILL BASED ON VERBAL ORDERS WILL BE ALLOWED. WORK DELETED BY THE OWNER, THAT WAS IN THE ORGINAL CONTRACT, WILL BE COMPUTED ON ESTIMATED COST AND ONE-HALF OF THE PROFIT ANTICIPATED FROM THE ITMES DELETED. EXTRA WORK SHALL BE PAID FOR ON THE FOLLOWING BASIS: A. ON ALL WORK WHICH ALTERS THE SCOPE OF WORK OF THE GENERAL CONTRACTOR AND AFFECTS SUB -CONTRACTORS REQUIRING EXTRA COORDINATION AND/OR SUPERVISION OF THE GENERAL CONTRACTOR, THE GENERAL CONTRACTOR SHALL BE PAID AS FOLLOWS: (1) COST OF MATERIALS. (2) COST OF LABOR. (3) COST OF SUB -CONTRACT FIGURED AS STIPULATED BELOW IN SUB -PARAGRAPH "B." (4) PLUS FIFTEEN (15%) PERCENT FOR OVERHEAD AND PROFIT. B. ON ALL WORK WHICH IS THE RESPONSIBILTY OF A TRADE OR SUB -CONTRACTOR WHICH DOES NOT ALTER THE SCOPE OF THE PROJECT OR INCREASE THE WORK OF THE GENERAL CONTRACTOR, THE GENERAL CONTRACTOR SHALL BE PAID AS FOLLOWS: (1) COST OF MATERIALS TO THE SUB -CONTRACTOR. (2) COST OF LABOR TO SUB -CONTRACTOR (3) PLUS FIFTEEN (15%) PER CENT FOR JOB OVERHEAD AND. PROFIT OF THE SUB -CONTRACTOR. (4) PLUS FIVE (5%) PERCENT FOR JOB OVERHEAD AND PROFIT OF THE GENERAL CONTRACTOR. WORK TO BE CLASSIFIED UNDER THIS CATEGORY SHALLL BE SUCH EXAMPLES, THOUGH NOT LIMITING THE SCOPE, AS CHANGE OR ADDITION OF LIGHT FIXTURES, FLOOR COVERING, HARDWARE, PAINTING, STORE FRONT AND UPGRADING OF EQUIPMENT. SALES TAX AND INSURANCE SHALL BE CONSIDERED AS PART OF MATERIAL AND LABOR COSTS. ANY ADDITIONAL BOND PREMIUM SHALL BE CONSIDERED TO BE INCLUDED IN THE PERCENTAGE FOR OVERHEAD. 8. GUARANTEE: THE GENERAL CONTRACTOR SHALL GUARANTEE ALL WORK UNDER THE CONTRACT FOR A PERIOD OF ONE (1) YEAR FROM THE DATE OF ACCEPTANCE BY THE ARCHITECT AND SHALL LEAVE THE WORK IN PERFECT ORDER AT COMPLETION AND NEITHER FINAL CERTIFICATE NOR ANY PROVISIONS IN THE CONTRACT DOCUMENTS SHALL RELIEVE THE CONTRACTOR OF THE RESPONSIBILITY FOR NEGLIGENCE OR FAULTY MATERIALS OR WORKMANSHOP WITHIN THE EXTENT AND PERIOD NAMED, AND UPON WRITTEN NOTICE, HE SHALL REMEDY ANY DEFECTS DUE THERETO AND PAY ALL EXPENSES FOR ANY DAMAGE TO WORK RESULTING SECTION 1A, PAGE 3 OF 4 THEREFROM. THIS GUARANTEE SHALL BE OF A LONGER PERIOD ON CERTAIN ITEMS WHERE SO DESIGNATED IN THE BODY OF THE SPECIFICATIONS. IF THE CONTRACTOR, AFTER DUE NOTICE FAILS TO COMPLY PROMPTLY WITH THE TERMS OF THE GUARANTEE, THE OWNER MAY HAVE THE DEFECTS CORRECTED, AND THE CONTRACTOR AND HIS SURETY SHALL BE LIABLE FOR ALL EXPENSE INCURRED. 9. PERFORMANCE BOND: PRIOR TO STARTING WORK UNDER THIS CONTRACT, THE CONTRACTOR SHALL FURNISH A SURETY BOND IN AN AMOUNT EQUAL TO ONE HUNDRED (100%) PERCENT OF THE CONTRACT PRICE. (VERIFY PERFORMANCE BOND REQUIREMENT WITH THE OWNER.) 10. SHOP DRAWINGS: SUBMITT ONE REPRODUCABLE PRINT OF LARGE SCALE SHOP DRAWINGS (WHERE CALLED FOR) TO THE OWNER FOR APPROVAL. REFER TO GENERAL CONDITIONS 4-12 SHOP DRAWINGS. 11. FIRE PROTECTION: THE CONTRACTOR SHALL PROVIDE ADEQUATE FIRE EXTINGUISHERS ON THE PREMISES DURING THE COURSE OF THE CONSTRUCTION PERIOD, OF THE TYPE AND SIZE AS RECOMMENDED BY THE NATIONAL BOARD OF FIRE UNDERWRITERS, TO CONTROL FIRES RESULTING FROM THE PARTICULAR WORK BEING PERFORMED, AND THE CONTRACTOR SHALL INSTRUCT HIS EMPLOYEES IN THEIR USE. ALL EXTINGUISHERS SHALL BE PLACED IN THE IMMEDIATE VICINITY OF THE WORK BEING PERFORMED READY FOR INSTANT USE. IN THE USE OF ESPECIALLY HAZARDOUS TYPES OF EQUIPMENT, SUCH AS ACTYLENE TORCHES, WELDING EQUIPMENT, TAR POTS, KETTLES ETC., NO WORK SHALL BE COMMENCED OR EQUIPMENT USED UNLESS FIRE EXTINGUSHERS OF A APPROVED TYPE AND CAPACITY ARE PLACED IN THE WORKING AREA AND AVAILABLE FOR IMMEDIATE USE BY THE WORKMEN USING THE ABOVE MENTIONED EQUIPMENT. 12 UTILITIES, LOCATIONS AND ELEVATIONS: LOCATIONS AND ELEVATIONS OF THE VARIOUS UTILITIES INCLUDED WITH IN THE SCOPE OF THIS WORK ARE OFFERED SEPERATE FROM THE CONTRACT DOCUMENTS AS A GENERAL GUIDE ONLY, WITHOUT GUARANTEE AS TO ACCURACY. EACH SUB -CONTRACTOR SHALL EXAMINE THE SITE AND SHALL VERIFY TO HIS OWN SATISFACTION THE.LOCATION AND ELEVATION OF ALL UTILITITES, AND SHALL ADEQUATELY INFORM HIMSELF AS TO THEIR RELATION TO THE WORK BEFORE ENTERING INTO A CONTRACT. 13. CLEAN-UP: PRIOR TO FINAL INSPECTON OF THE BUILDING AND OCCUPANCEY BY THE OWNER, CLEAN ALL PARTS OF THE BUILDING. 14. CERTIFICATES FOR PAYMENT: REFER TO GENERAL CONDITIONS, SUB -PARAGRAPH 9.4.1, LINE 6 AND AFTER THE WORDS "PROPERLY DUE" AND ADD "LESS 10% RETAINAGE." 15. WARRENTY: REFER TO GENERAL CONDITIONS, SUB -PARAGRAPH 4.5.1 AND ADD "CONTRACTOR WILL AND DOES WARRENT ALL WORK PERFORMEND UNDER THIS CONTRACT FOR ONE YEAR (EXCEPT AS OTHERWISE REQUIRED FOR A LONGER PERIOD) AFTER DATE OF FINAL CERTIFICATE OF PAYMENT OF CERTIFICATE OF SUBSTANTIAL COMPLETION, WHICH EVER IS ISSUED FIRST." 16. DRAWINGS AND SPECIFICATIONS FURNISHED: CONTRACTOR WILL BE FURNISHED UP TO 10 SETS OF PLANS AND SPECIFICATIONS. ADDITIONAL SETS REQUIRED MAY BE PURCHASED AT PRINTING COSTS. SECTION 1A, PAGE 4 OF 4 SECTION 3A CONCRETE 3A-1 STANDARD: AMERICAN CONCRETE INSTITUE (ACI) 318 "BUILDING CODE REQUIREMENTS FOR REINFORCED CONCRETE",ACI 347 "RECOMMENDED PRACTISE FOR CONCRETE FORMWORK", AND LOCAL BUILDING CODES. INTERPRET "BUILDING OFFICAL" APPEARING IN ACI CODE TO MEAN OWNERPS REPRESENTATIVE. A. BARS: DEFORMED ASTM A615, GRADE 60. B. 12 BARS: SMOOTH, INTERMEDIATE GRADE - ASTN A306. C. WELDED WIRE MESH: ELECTRICLY WELDED, COLD DRAWN WIRE - ASTM A185. D. SUBMIT SHOP DRAWINGS PER SECTION 1A. 3A-4 MATERIALS: A. WATER: CLEAN AND POTABLE B. CEMENT: PORTLAND CEMENT, TYPE 1 ASTM-C150 C. AIR-ENTRANING ADMIXTURE: ASTM-C260 "SPECIFICATIONS FOR AIR ENTRAINING ADD MIXTURES". USE IN ALL CONCRETE EXPOSED TO WEATHER ON BUILDING, PAVEMENT, CURBS, GUTTER ETC. AND ALL PORTIONS OF THE BUILDING WHEN AIR TEMPERATURE IS BELOW 40 DEGREES F.. AMOUNT ENTRAINED AIR TO BE 4 TO 6 BY VOLUME. 3A-5 AGGREGATES: CONFORM TO "SPECS FOR CONCRETE AGGREGATES" ASTM C33. MAX. SIZE 1 1/21' DIA. 3A-6 CHARACTERISTICS: A. MAXIMUM WATER CEMENT RATIO 6 1/2 GAL/SACK. B. MINIMUM CEMENT CONTENT 5 1/4 BAGS/CUBIC YARD. C. COMPRESSIVE STRENGTH AT 28 DAYS 3500 PSI D. SLUMP: 3 TO 5 INCHES PER ASTM C143, "METHOD OF TEST FOR SLUMP - PORTLAND CEMENT CORPORATION" SECTION 3A, PAGE 1 OF 2 3A-7 READY -MIXED CONCRETE: MIX AND TRANSPORT PER ASTM C 94 "SPECS. • i READY -MIXED 3A-8 PLACING: BEFORE PLACING CONCRETE, FORMS SHOULD BE OILED OR WETTED, ALL WATER AND ICE REMOVED, REINFORCEMENT CLEAN AND ENTIRE PREPA-VATION APPROVED. 3A-9 CONSOLIDATION: CONSOLIDATE BY VIBRATION, SPADING OR RODING, THROUGHLY WORK AROUND Oit, REINFORCEMENT N: • !' it IMBEDDED ITEMS. HONEYCOMBING, PITTING OR PLANES OF WEAKNESS. 3A-10 WEATHER CONDITIONS: PLACE NO CONCRETE WHEN AIR TEMPERATURE IS 40 DEGREES F. AND FALLING. DURING AND FOR 3 DAYS AFTER PLACING, MAINTAIN MIN. TEMPERATURE OF CONCRETE AT 50 DEGREES F.- PROTECT FROM FREEZING FOR 3 DAYS FOLLOWING THE INITIAL 3 DAYS. PLACING TEMPERATURE OF CONCRETE DURING HOT WEATHER SHALL NOT CAUSE LOSS OF SLUMP, FLASH SET OR •LD JOINTS. MAX. TEMPERTURE OF ♦ ` 0 DEGREES F.. FORMED3A-11 FINISHING: A. (EXPOSED REMOVE • PROJECTIONS, FILL AND REPAIR HONEYCOMBS, HOLES AND DEPRESSIONS. •• } SURFACE. t- i tSMOOTH, C. WALKS DSTEPS:•• FLOAT 3A-12 CURING: KEEP CONTINUOUSLY MOISTFOR 7 DAYS BY CONTINUOUSLY SECTION 4A MASONRY —GENERAL 4A-1 CODES AND REFERENCE SPECS: A. LOCAL BUILDING CODE HAVING JURISDICTION B. NATIONAL CONCRETE MASONRY ASSOCIATION "GUIDE SPECS. FOR CONCRETE MASONRY" 4A-2 WORKMANSHIP: FIRST CLASS WITH ALL WORK PLUMB AND TRUE TO LINE. VERTICAL JOINTS IN ALTERNATE COURSES SHALL ALIGN. HORIZONTAL COURSES LEVEL. FULL 3/8" MORTAR BED AND JOINTS. 4A-3 PROTECTION: DO NO WORK WHEN TEMPERATURE IS BELOW 40 DEGREES F OR WHEN TEMPERATURE IS EXPECTED BELOW 35 DEGREES F WITHIN 24 HOURS. PROTECT AGAINST FREEZING FOR 48 HOURS AFTER LAYING. COVER TOP OF WALLS AT END OF EACH DAY AND WHEN RAIN APPEARS EMINENT. 4A-4 BUILT—IN WORK: BUILD IN ALL ANCHORS, NAILING INSERTS, SLEEVES, FLASHING ETC. AS SHOWN OR REQUIRED. EACH ITEM SHALL BE SOLIDLY BUILT—IN AS WORK PROGRESSES. OPENINGS SHALL BE LAID OUT AND BUILT IN ACCURATELY. 4A-5 SAMPLE PANEL: BEFORE BEGINNING WORK ERECT FOR APPROVAL A 4'-0" X 4'-0" PANEL(S) SHOWING COLOR RANGE, TEXTURE, BOND, MORTAR JOINT AND WORKMANSHIP OF MASONRY MATERIALS. APPROVED PANELS WILL BECOME STANDARD OF COMPARISON FOR MASONRY WORK. DO NOT DESTROY OR MOVE UNTIL WORK IS COMPLETE. 4A-6 SUBMITTALS: SUBMIT REPRESENTATIVE SAMPLES (2) OF ALL UNITS SPECIFIED. WHEN SELECTION OF COLOR IS TO BE MADE, SUBMIT COMPLETE COLOR RANGE. 4A-8 MASONRY REINFORCING: FACTORY PRODUCED ZINC COATED (ASTM A-116,CLASS 2), #9 GUAGE COLD DRAWN STEEL WIRE (ASTM A-32), TRUSSED DESIGN. WIDTH: 2" LESS THAN NOMINAL WIDTH WALL. LAP JOINTS 12". 4A-9 MORTAR: MORTARA. GENERAL: ALL • BE ACCURATELYs BY VOLUME, BATCH MECHANICAL MIXER AT LEAST 3 MINUTES AFTER ALL INGREDIENTS ADDED. RETEMPER AS REQUIRED WITH A LITTLE WATER AS NEEDED TO KEEP BOARDSWORKABLE. DISCARD IF MOT USED WITHIN ONE HOUR. MORTAR BOXES AND i BE CLEANED FOR EACH BATCH AND AT END OF DAYS WORK. 01101z W.' • 'N' MASONRY CEMENT, USING ONE PART CEMENT TO 2 3/4 PARTS CLEAN BEST GRADE SAND. SAND TO BE GRADED FINE TO COARSE, TO BE PASSED THROUGH #3 SIEVE BEFORE USING. D. a i , w COLOR: MORTAR SHALL 'w TINTED TO 14ATCH BRICK COLOR. MORTAR COLORS,TO BE TINTED USE NON —STAINING, NON -FADING TINTS BY ANTIHYDRO, DAVIS OR r SECTION 4A, PAGE 2 OF 2 SECTION ,. s - 4A-1 CODES AND REFERENCE SPECS: LOCALA. •DJURISDICTION MASONRY"B. NATIONAL CONCRETE MASONRY ASSOCIATION "GUIDE SPECS. FOR CONCRETE WORKMANSHIP: O> COURSESVERTICAL JOINTS IN ALTERNATE •- •COURSES MORTARLEVEL. FULL 3/8" BED AND JOINTS. 4A-3 PROTECTION: DO NO WORK WHEN TEMPERATURE IS BELOW 40 DEGREES F OR WHEN TEMPERATURE IS EXPECTED BELOW 35 DEGREES F WITHIN 24 HOURS. PROTECT AGAINST FREEZING FOR 48 HOURS AFTER LAYING. COVER TOP OF WALLS AT END OF EACH DAY AND WHEN RAIN APPEARS EMINENT. 4A-4 BUILT-IN WORK: BUILD IN ALL ANCHORS, NAILING INSERTS, SLEEVES, FLASHING ETC. AS SHOWN OR REQUIRED. EACH ITEM SHALL BE SOLIDLY BUILT-IN AS WORK PROGRESSES. OPENINGS SHALL BE LAID OUT AND BUILT IN ACCURATELY. 4A-5 SAMPLE PANEL: N.A. 4A-6 SUBMITTALS: SUBMIT REPRESENTATIVE SAMPLES (2) OF ALL UNITS SPECIFIED. WHEN SELECTION OF COLOR IS TO BE MADE, SUBMIT COMPLETE COLOR RANGE. 4A-8 MASONRY REINFORCING: FACTORY PRODUCED ZINC COATED (ASTM A-116,CLASS 2), #9 GUAGE COLD DRAWN STEEL WIRE (ASTM A-32), TRUSSED DESIGN. WIDTH: 21" LESS THAN NOMINAL WIDTH WALL. LAP JOINTS 12". B. FOR TYPICAL MASONRY: MAGNOLIA MASONS MIX, MEDUSA BRIZZET, ATLAS MORTAR CEMENT, OR BROZMENT LIGHT COLORED LIME BASE, NON -STAINING TYPE MASONRY O... O:.. PART :... 1. PARTS BEFOREGRADE SAND. SAND TO BE GRADED FINE TO COARSE, TO BE PASSED THROUGH #3 SIEVE SECTION 4A, PAGE 1 OF 2 4B-1 GENERAL: SEE SECTION 4A 4B-3 COMMON BRICK: (FOR USE WHERE NOT EXPOSED) MODULAR SIZED HARD COMMON BRICK MEETING ASTM STANDARD C62-50,GRADE MW. 4B-4 COURSES AND JOINTS: LAY IN RUNNING BOND SO THAT 3 COURSES EQUAL 811 ALIGN WITH BACKUP MASONRY. JOINTS SHALL BE STRUCK OFF FLUSH AND WHEN PARTIALLY SET TOOLED AND COMPACTED TO GIVE CONCAVE JOINT. 4B-5 LAYING: EACH BRICK SHOVED INTO PLACE. BEDS FULL, SOLID AND UNIFORM. HEAD JOINTS COMPLETELY FILLED WITH MORTAR BY BUTTERING ENTIRE END OF BRICK AND SHOVING INTO PLACE; SLUSHING OPEN JOINTS WILL INDICATE POOR WORKMANSHIP. 4B-6 POINTING AND CLEANING: REMOVE MORTAR DRIPINGS AND CAREFULLY FILL ALL VOIDS WITH MORTAR. 4B-7 EXPOSED BRICK: DO NOT PROCEED UNTIL THREE WEEKS AFTER LAYING. REMOVE LARGE PARTICLES OF MORTAR WITH CHISEL AND WIRE BRUSH. THEN CLEAR SMALL AREAS AT A TIME WITH SOLUTION MANUFACTURED FOR THIS PURPOSE AND STIFF FIBERED BRUSH, FLUSHING WALL WITH WATER FROM HOSE BEFORE AND AFTER WASHING. AVOID SCRUBBING JOINTS. REPLACE SOLUTION WHEN IT BECOMES DIRTY. C. N. A. SECTION 4A, PAGE 2 OF 2 SECTION 4C CONCRETE BLOCK CONFORM • ASTM SPECIFICATION HOLLOW LOADLONG X NOMINAL WIDTHSf EXPOSED TO VIEW SHALL BE SINGLE SCORED FACE BLOCK. FURNISH CORNER, CAP BLOCKS # OTHER SHAPES• 1 4i AND COURSING: APPROX. 3/8" THICK • THAT ONE ! TOOLED•'CONTRACTOR OUT !R THROUGHMASONRY WILL COURSE UP OPENINGS, 4D-4 LAYING: INACCORDANCE WITH NCMA RECOMMENDATIONS, WITH FULL MORTAR COVERAGE ON VERTICAL AND HORIZONTAL FACE SHELLS. JOINTS WELL COMPACTED. 4C-5 POINTING AND CLEANING: REMOVE MORTAR DRIPPINGS AND CAREFULLY FILL ALL VOIDS WITH MORTAR. SECTION 4C, PAGE 1 OF 1 REFERENCELATEST EDITION UNLESS •; OTHERWISE. A. AMERICAN INSTITUTE OF STEEL CONSTRUCTION (AISC) SPECS. FOR THE DESIGN, FABRICATION AND ERECTION OF STRUCTURAL STEEL FOR BUILDINGS. B. AMERICAN IRON AND STEEL INSTITUTE (AISI) SPECS. - THE DESIGN OF LIGHT GAUGE COLD -FORMED STEEL STRUCTURAL MEMBERS. AMERICANC. SOCIETY STANDARD CODE FORAND GAN WELDING IN BUILDING CONSTRUCTION. D. NATIONAL ASSON OF ARCHITECTURAL METAL MANUFACTURERS (NAAMM) ARCHITECTURAL METAL HANDBOOK. 5A-2 SHOP DRAWINGS: SHOWING EACH ITEM, SIZES, METHOD OF FABRICATION, FINISHES AND INSTALLATION DETAILS, INCLUDING LOCATION OF HOLES, ANCHORS AND OTHER PERTINENT DATA. 5A-3 FIELD MEASUREMENTS: VERIFY DIMENTIONS IN THE FIELD FOR ACCURATE FIT OF SPECIFIED WORK. 5A-4 MISCELLANEOUS METALS: A. GENERAL: FURNISH ALL MATERIAL D OPERATIONS IN CONNECTION INSTALLATION OF IRON, B. STEEL: 1. BARS AND STRUCTURAL SHAPES, HOT ROLLED - ASTM A-36. 2. BARS, COLD FINISH - ASTM A108, GRADE 1018. 3. STRUCTURAL TUBING - ASTM A500. 4. SHEET - ASTM A366 (EXPOSED MEMBER -STRETCHER LEVELED) 5. GALVANIZED SHEETS - ASTM 525, 1.25 02 CLASS COATING UNLESS OTHER WISE NOTED. 6. WROUGHT IRON - ASTM A41 7. PLATE - ASTM A283, GRADE C. 8. PIPE ASTM A53, A500 OR A501 9. FASTENERS: A. EXPANSION SHIELDS - FF-S-325 B. STEEL BOLTS ASTM A 325 10. ANCHORS: PROVIDE THOSE REQUIRED TO SECURE WORK IN PLACE. C. PAINT (PRIMER): REMOVE MILL SCAB, RUST, ETC. 1. STEEL: ZINC CHROMATE II-P-645 OR SYNTHETIC ALKYD VARNISH TT-P-636B. 2. GALVANIZED: TT-P-64 LB. ZINK-DUST, ZINC OXIDE, TYPE II. D. GALVANIZED COATING: HARDWARE (ASTM A153), ASSEMBLED STEEL PRODUCTS (ASTM A386), PIPE (ASTM A120) E. WORKMANSHIP: CONCEALED1. WELDS: AWS CODE AND FINISH FLUSH AND SMOOTH WHERE EXPOSED. 2. FASTENINGS: POSSIBLE. JOINTS:3. . MILL EXPOSED SMOOTH. REMOVE SHEAR BURRS FROM SHEET STOCK. 4. i TWO COATS CONTACTTO ALUMINIUM SURFACES IN DISSIMILAR SMOOTH.F. ANCHORAGE: CAST IN PLACE WHERE POSSIBLE. ANCHOR BOLT 1/2" DIA. UNLESS SHOWN OTHERWISE. CUT OFF 1/8" FROM FACE OF NUT AND FILE * womfie ! ` ` SECTION 5A, PAGE 2 OF 2 t 6A-1 REFERENCE STANDARDS: A. WESTERN PINE ASSOCIATION STANDARD GRADING B. SOUTHERN PINE ASSOCIATION STANDARD GRADING • SOUTHERN PINE LUMBER. PRODUCT STANDARD, FOR SOFT WOOD PLYWOOD. D. ARCHITECTURAL WOODWORK INSTITUTE (AWI) QUALITY STANDARDSm . 6A-2 GRADING ANDMARKING: EACH PIECE OF LUMBER AND SIDING SHALL BEAR "GRADE MARK", "TRADE MARK",AND "MILL IDENTIFICATION" OF APPROPRIATE INSPECTION BUREAU OR ASSOCIATION; MATERIAL WITH DEFECTS THAT PREVENT ITS SERVING ITS INTENDED PURPOSE REGARDLESS OF GRADE WILL BE REJECTED AND REPLACED WITH ACCEPTABLE AN PIECE. ..MOISTUREAND EXTERIOR 19%; INTERIOR FINISH WOODWORK: 12%. PRODUCT HANDLING:OFF „s"" • VENTILATION.COMPLETELY PROTECTED AGAINST THE WEATHER, STACK LUMBER IN A MANNER TO INSURE a.-5 WORKMANSHIPINCONFORMANCE WITH •.f TRADE PRACTISE. CAREFULLYRECOMMENDATIONS OF MANUFACTURERS, BUILDING CODES AND THE DRAWINGS ANN i INSTALL CARPENTRY SCREWSSUFFICIENT NAILS, SPIKES, • BOLTS TO INSURE RIGIDITY AND PERMANENCE... PLUMB AND SIDES. B. ROUGH HARDWARE: PROVIDE ALL ITEMSROUGH WORK.AS SPIKES, CLIPS, STEEL HANGERS, NAILS, BOLTS, TOGGLE BOLTS, ANCHOR BOLTS, WOOD SCREWS, AND STRAPS NECESSARY FOR INSTALLATION OF SPECIFIED OF OF SIZE i LENGTH TO DRAW THE •'FIRMLY TOGETHER. 6A-7 WORK —IN —PLACE: EXAMINE EXISTING WORK ON WHICH SPECIFIED WORK IS DEPENDANT. NOTIFY ARCHITECT WRITING. INFLUENCE SATISFACTORY COMPLETION AND PERFORMANCE OF THE WORK. FAILURE TO NOTIFY ARCHITECT WILL BE CONSTRUED AS ACCEPTANCE OF • ' SECTION 6A, r f • ROOM . • 6B-2 MATERIALS: FRAMING,A. DIMENSION LUMBER: ! BLOCKING NOMINALLY• INCHES OR OVER STANDARD OR NO. 2 COMMON GRADE OR B. BOARDAND BLOCKING UNDERf DIMENSION - STANDARD OR NO. 3 COMMON. C. TREATED LUMBER (WOLMANIZED OR EQUAL): EACH PIECE DELIVERED TO JOB SITE SHALL BEAR IDENTIFICATION STAMP OR BRAND, INLIEU THEREOF, FURNISH ARCHITECT WITH NOTARIZED CERTIFICATE OF COMPLIANCE. COAT CUT TREATED LUMBER WITH 2 COATS OF THE CONCENTRATED PERSERVATIVE SOLUTION. INPREGNATE IN ACCORDANCE WITH WOOD PRESERVATIVE MANUFACTURE, MINIMUM .35P S PER CUBIC FOOT OF PENTA CHLOROPHENOL PRESERVATIVE. USE TREATED LUMBER WHERE EMBEDED IN OR IN CONTACT WITH CONCRETE OR MASONRY. +. �.. *fi E. PLYWOOD: U. S. PRODUCT STANDARD PS-1 (NON -VENEERED STRUCTURAL PANELS EQUAL TO ""OSB-INNER SEAL" BY LOUSIANA PACIFIC MAY BE USED AT NON-VISABLE LOCATIONS, i.e. SUB -FLOOR SHEATHING, ROOF DECK ETC. 141*46 "ov, 2 f s A. MOULDING & TRIM: C AND BETTER Ar STANDARD MOULDING GRADE. SELECTEDB. LAMINATED PLASTIC: 1/1611 THICK, COLOR AND PATTERN AS BY THE ARCHITECT EQUALTO O. OR i ! D. SIDING: NO. 1 - MATCH EXISTING E. BIRCH PLYWOOD: "PREMIUM" OR "PAINT GRADE" AT PAINTED CABINETS F. FLOORING: MATCH ORIGINAL CONFIGURATION: OAK: SELECT FOR EDGE GRAIN, NO FLAT GRAIN. PINE: CLEAR 6C-3 WORKMANSHIP: A. MILLWORK: MILLWORK, TRIM AND BRACING SHALL BE INSTALLED WITH TIGHT JOINTS. RUNNING TRIM SHALL BE IN LONG LENGTHS AND JOINTED ONLY WHERE SOLID FASTENINGS CAN BE MADE. MITER ALL JOINTS AND CORNERS AND COPE ANGLES. FASTEN EXTERIOR TRIM WITH ZINC COATED NAILS AND INTERIOR TRIM WITH FINISHING NAILS WITH HEADS SET FOR PUTTY. SAND WOODWORK AS NECESSARY TO REMOVE IRREGULARITIES AND LEAVE FREE OF BLEMISHES, PLANNER MARKS AND DEFECTS. SECTION 6C, PAGE 1 OF 1 SECTION 7A INSULATION 7A-1 BATT INSULATION: PRODUCT THICKNESS AS INDICATED OR REQUIRED, 12" EQUAL R-38, 6" EQUAL R-19, AND 3 1/2" EQUAL R-11. BATTS MADE OF SPUN GLASS FIBER FORMED INTO NEAT MAT WITH KRAFT PAPER VAPOR ON ONE SIDE WHICH FORMS FLANGES. EQUAL TO OWENS-CORNING CORP ."FIBERGLAS" 7A-2 HANDLING: DELIVER MATERIALS TO JOB IN UNOPENED PACKAGES OR CONTAINERS WITH MANUFACTURERS NAME, BRAND AND OTHER PERTINENT INFORMATION CLEARLY MARKED THEREON. STORE OFF GROUND AND PROTECTED FROM MOISTURE AND DIRT. 7A-3 INSTALLATION: SECURE IN PLACE, TIGHTLY BUTTED AGAINST ADJOINING BATTS AND MATERIALS WITH VAPOR BARRIER TOWARD THE HEATED AND COOLED SPACE. STUFF LOOSE FIBERGLASS IN VOIDS TOO SMALL TO FIT FULL BATTS. FILL VOIDS 1/2" OR SMALLER WITH LOOSE FIBERGLASS OR URATHANE FOAM CAULK. SECTION 7A, PAGE 1 OF 1 SECTION 7B WATERPROOFING AND CAULKING 7B-1 WORK EXTENT: CONSISTS OF INTERIOR DAMPROOFING BELOW SLABS, CAULKING AROUND ALL EXTERIOR TRIM OR WHERE REQUIRED TO SECURE A NEAT AND TIGHT JOB. 7B-2 MATERIALS: A. MEMBRANE DAMPROOFING: UNDER CONCRETE SLABS ON GRADE., .006 INCH THICK POLYETHYLENE FILM SIMILAR TO VISQUEEN. B. CAULKING: (INTERIOR) 1. MATERIALS: PECORA, KUHLS OR DICKS-ARMSTRONG-PONTIUS FIRST QUALITY, NON -STAINING, GUN GRADE, ELASTIC CAULKING COMPOUND MEETING FED. SPEC. TT-C-598 GRADE 1, APPLIED WITHOUT THINNING. 2. TYPICAL APPLICATION: AROUND EXTERIOR DOORS, WINDOWS, WOOD JOINTS, ETC., AND ELSEWHERE SHOWN OR REQUIRED. 3. SEATING THRESHOLD: INSTALL ALL EXTERIOR THRESHOLD IN FULL BED OF CAULKING COMPOUND. C. EXTERIOR CAULKING: 1. POLYSULFIDE BASED SEALENT: SEALENT SHALL BE ONE COMPONENT, READY TO USE TYPE, SIMILAR TO "SYNTHCALK GC-9" BY PECORA. THE SEALENT SHALL BE A CURING TYPE AND COMPLY WITH THE PUBLISHED SPECIFICATIONS OF THE MANUFACTURER OR ASA SPECIFICATION A 116.1 WITH EXCEPTIONS AS LISTED BY THE MANUFACTURER. STANDARD COLOR AS SELECTED BY THE ARCHITECT. D. INSTALLATION: INSTALL IN ACCORDANCE WITH MANUFACTURERS RECOMMENDED PROCEEDURES. 1. INTERIORS: AT ALL JOINTS, CRACKS, ETC. FOR UNIFORM AIR TIGHTNESS AND VISUAL COMPLETENESS. 2. EXTERIORS: AT ALL JOINTS, CRACKS; ETC FOR WATERTIGHT AND AIR TIGHT INSTALLATION. SECTION 7B, PAGE 1 OF 1 SECTION 7C SHEET METAL 7C-1 REFERENCE STANDARDS: NATIONAL ASSOCIATION OF SHEET METAL CONTRACTORS, "STANDARD PRACTICE FOR SHEET METAL WORK." 7C-2 MATERIALS: UNLESS OTHERWISE NOTED USE 24 U.S. STD. GAUGE GALVANIZED IRON (ASTM A-129-47 TYPE A) COPPER BEARING STEEL FOR INTERIOR WORK AND "PAINT GRIP" FOR EXTERIOR WORK. SOLDER (ASTM B 32060T) 50% TIN AND 50% LEAD. 7C-3 FABRICATION: LINES, MOULDING, AND EDGES SHARP AND TRUE, REINFORCE AS REQUIRED FOR STIFFNESS. FORM NEAT JOINTS AND SEAMS WITH SURFACE FREE FROM WAVES AND BUCKLES. 7C-4 INSTALLATION: LEVEL, NEAT AND TRUE TO LINE. MAKE PROPER ALLOWANCE FOR EXPANSION. MAKE EXTERIOR WORK PERMANENTLY WEATHER TIGHT. SECTION 7C, PAGE 1 OF 1 SECTION 7E SHINGLE ROOF (COMPOSITION) 7E-1 MATERIALS A. 15LB. PLAN FELT: FED SPEC HH-F-191A (2) TYPE 1 B. CERTAINTEED SEALDON CLASS C (235 LB.) C. NAILS: GALVANIZED ROOFING NAILS. D. 90# MINERAL SURFACE ROOFING: FED SPED SS-R-630 CLASS 1. E. FLASHING CEMENT: FED. SPEC. SS-C-153 TYPE 1. 7E-2 INSTALLATION: APPLY OVER ROOF AS FOLLOWS: APPLY 15 LB. FELT OVER SLOPE OF DECK,THE APPLY SHINGLES AS PER MANUFACTURERS RECOMMENDATIONS ON PACKAGE. VALLEY SHALL BE 2 PLIES OF 90# MINERAL SURFACE ROLL ROOFING. THE BOTTOM PLY SHALL BE 16" WIDE AND TOP PLY 20" WIDE. CONCEAL ALL NAIL HEADS. CUT VALLEYS STRAIGHT. SECTION 7E, PAGE 1 OF 1 SECTION 8A WOOD DOORS 8A.1 REFERENCE SPECIFICATIONS 8A.1.1 NATIONAL WOODWORK MANUFACTURERS' ASSOCIATION 8A.1.2 ARCHITECTURAL WOODWORK INSTITUTE 8A.2 SUBMITTALS: SUBMIT BROCHURES OF EACH DOOR, SHOWING CONSTRUCTION AND FINISH. 8A.3 DOORS: CUSTOM GRADE 8A.4 HANDLING: PROTECT FROM DAMAGE. DELIVER TO JOB SITE IN PROTECTIVE CARTONS OR BAGS. WHEN NORMAL TEMPERATURE AND HUMIDITY CONDITIONS APPROXIMATE THE INTERIOR CONDITIONS THAT WILL EXIST WHEN THE BUILDING IS OCCUPIED, INSTALL DOORS. 8A.5 GUARANTEE: GUARANTEE DOORS FOR 5 YEARS, AFTER OWNER ACCEPTANCE, AGAINST WARPING, TWISTING OR MANUFACTURING DEFECTS WHEN ACCORDED TREATMENT RECOMMENDED BY THE NWMA FOR STOARAGE, INSTALLATION AND MAINTENANCE. CONTRACTOR GUARANTEES REPLACEMENT OF DEFECTIVE DOOR AS DEFINED BY NWMA STANDARD DOOR GUARANTEE AND SHALL DO SO WITH IN TEN DAYS AFTER RECEPT OF NOTICE FROM OWNER. SECTION 8A, PAGE 1 OF 1 SECTION 8F GLASS AND GLAZING 8F-1 _EXTENT: ALL GLASS, GLAZING AND RELATED ITEMS NECESSARY TO COMPLETE THE WORK INDICATED ON DRAWINGS AND DESCRIBED IN SPECIFICATIONS. 8F-2 TYPE AND QUALITY OF GLASS: A. GENERAL REQUIREMENTS FOR ALL GLASS: EXCEPT AS SPECIFIED ALL GLASS SHALL COMPLY WITH REQUIREMENTS OF FEDERAL SPECIFICATIONS DD-G-451A, APPLICABLE TO THE TYPE SPECIFIED. SAFETY GLASS REQUIRED AT ALL ENTRANCE DOORS, SHOWER DOORS AND WHERE SHOWN ON DRAWINGS IN ACCORDANCE WITH AMERICAN NATIONAL STANDARDS INSTITUTE Z-97.1 LATEST ADDITION. B. PLATE GLASS: 1/4" FLOAT , FREE FROM DISTORTION. CLEAR UNLESS SHOWN OTHERWISE ON DRAWINGS. C. WINDOW GLASS: 1/8" DOUBLE STRENGTH, "B" GRADE 8F-3 MATERIALS FOR GLAZING: A. PUTTY (WOOD FRAMES): BEST GRADE PRODUCTS AS MANUFACTURED BY PECORA OR DICKS ARMSTRONG PONTIUS IN STANDARD COLOR AS SELECTED. PUTTY FOR WOOD FRAMES SHALL CONFORM TO FED SPEC TT-P-791A, TYPE 1 WHITTING PUTTY. SECTION 8F, PAGE 1 OF 1 SECTION 9A PAINTING 9A-1 SCOPE: INCLUDE ALL SURFACES REQUIRED FOR COMPLETE AND FINISHED JOB UNLESS EXPRESSLY ELIMIMATED. 9A-2 ACCEPTANCE OF SURFACES: DO NOT WORK UNTIL SURFACES TO BE FINISHED ARE IN PROPER CONDITION. BEGINNING OF WORK WILL CONSTITUTE ACCEPTANCE. 9A-3 COLORS: COLOR SCHEDULE WILL BE FURNISHED BY ARCHITECT IN ADVANCE OF BEGINNING WORK, MADE UP WHERE POSSIBLE FROM STANDARD COLOR CHIPS OF CHOSEN MANUFACTURER. SELECTIONS WILL NOT BE LIMITED TO ANY SINGLE MANUFACTURERS STOCK COLORS, NOR TO THE NUMBER OF COLORS SELECTED OF ANY AREA. 9A-4 MATERIAL: BEST GRADE PRODUCT OF DUPONT, PITTSBURG, SHERWIN-WILLIAMS, DEVOE, GREY SEAL OR BENJAMIN MOORE. ALL DELIVERED TO JOB IN ORIGINAL UNBROKEN CONTAINERS. SAME BRAND OF PAINT, STAIN, VARNISH ETC. SHALL BE USED ON ANY -ONE PHASE OF WORK. 9A-5 APPLICATION: A. TEMPERATURE: NO EXTERIOR PAINTING DURING WET WEATHER OR WHEN TEMPERATURE IS BELOW 50 DEGREES F.. BUILDING INTERIOR SHALL BE MAINTAINED CONTINUOUSLY AT 65 DEGREES F. OR ABOVE. B. CONDITION OF SURFACES: CLEAN, DRY, SMOOTH, FREE OF DUST, SCRATCHES, HAMMER OR PLANNER MARKS. C. PROTECTION: PROTECT SHURBBERY, LAWNS, SURFACES AND OBJECTS INSIDE AND OUTSIDE THE BUILDING FROM SPLATTER, OVERSPRAY OR ANY OTHER DAMAGE. D. APPLICATION: IN ACCORDANCE WITH MANUFACTURERS DIRECTIONS. 9A-6 PRIMING, BACKPRIMING ETC.: A. EXTERIOR MILLWORK: BACK AND END PRIME BEFORE ERECTION. FACE PRIME BEFORE OR IMMEDIATELY AFTER ERECTION. BACK PRIMING MAY BE OMITTED ON MEMBERS WHICH ARE PRESSURE TREATED. B. INTERIOR MILLWORK: BACK AND END PRIME BEFORE ERECTION. C. CABINET WORK: BACK AND END PRIME OR SEAL BEFORE INSTALLATION. D. WOOD DOORS: TOP AND BOTTOM EDGES SHALL RECIEVE 2 COATS OF SPECIFIED FINISH AFTER FITTING. SECTION 9A, PAGE 1 OF 2 9A-7. SPECIFIC APPLICATIONS A. EXTERIOR IRON AND STEEL: B. GALV. IRON AND STEEL: C. EXTERIOR WOOD: D. PAINTED INTERIOR WOOD: E. CABINETS: (WHERE STAINED) F. GYPSUM BOARD: G. EXTERIOR TIN H. EXISTING INTERIOR ENAMEL SURFACES J. WOOD PORCH AND STEPS K. EXISTING RUSTED METAL TOUCH UP PRIME COAT WITH METAL PRIMER TWO COATS EXTERIOR ALYKD PAINT PRIME WITH ZINC DUST PRIMER. TWO COATS EXTERIOR ALYKD PAINT PRIME WITH ALYKD PRIMER COAT TWO COATS EXTERIOR LATEX HOUSE PAINT PRIME W/ ALKYD ENAMEL UNDERCOAT (TINT TO MATCH) 2ND COAT: SEMI -GLOSS ALYKD ENAMEL OIL STAIN - RUBBED TO COLOR SELECTED TWO COATS POLYURATHANE VARNISH TWO COATS VINYL LATEX (NOTE: DO NOT USE HEAVY SPRAYED TEXTURE AT CEILINGS. USE ONLY LIGHT STIPPLE OR ORANGE PEEL TEXTURE. TWO COATS HEAVY BODIED ALYKD PAINT EQUAL TO "RUSTOLEUM" SAND SMOOTH, CLEAN WITH DEGLOSSER AND REPAINT AS ABOVE. THOROUGHLY CLEAN SURFACES TWO COATS URETHANE BASED PORCH AND DECK ENAMEL REMOVE LOOSE MATERIAL PRIME WITH URETHANE MODIFIED OIL BASE PAINT PRIMER EQUAL TO BRUNING "SILATHANE" PAINTING 9A, PAGE 2 OF 2 SECTION 9B DRYWALL INTERIOR FINISH 9B-1 SCOPE OF WORK A. EXTENT: FURNISH ALL MATERIALS, LABOR AND EQUIPTMENT REQUIRED OR INCIDENTAL TO APPLICATION OF ALL GYPSUM BOARD FINISHES NECESSARY TO COMPLETE BUILDING. 9B-2 MATERIAL: A. U.S.G. "SHEETROCK" OR NGC "GOLD BOND" GYPSUM WALL BOARD, 1/4", 1/2" AND 5/8"THICK, 4'-0" WIDE SHEETS WITH TAPERED EDGE, LENGTHS AS PRACTICAL TO WORK OUT WITH MINIMUM JOINTS. DELIVER TO JOB IN ORIGINAL UNBROKEN CONTAINERS AND PROTECT FROM ELEMENTS AND OTHER DAMAGE. USE 1/2 CEMENT BOARD ("DURAROCK" OR EQUAL) IN DAMP LOCATIONS. 1/2" INCH THICK AT 16" STUD SPACING. APPLY HORIZONTALLY WITH EDGE SPACED A MINIMUM OF 1/4" ABOVE THE LIP OF THE TUB, LIP OF THE SHOWER RECEPTER OR SUB -PAN. C. EXTERIOR SHEATHING: EXTERIOR GRADE GYPSUM BOARD SHEATHING CONFORMING TO A.S.T.M. C79. 1/2" THICK AT 16" STUD SPACING OR 5/811 THICK AT 24" STUD SPACING. 9B-3 INSTALLATION: APPLY VERTICALLY ON WALLS IN ONE PIECE FLOOR TO CEILING AT WALLS, ALL JOINTS ON BEARING. NAIL ALONG EACH BEARING 811 O.C., WITH GWB-54, 1 1/4" ANNULAR RING, 1/4" HEAD, MEDIUM DIAMOND POINT NAIL IN WOOD OR 1 1/4" RUST RESISTANT STEEL, BUGLE HEADED GYP. BOARD SCREWS. 9B-4 JOINT TREATMENT: IN STRICT ACCORDANCE WITH MANUFACTURERS RECOMMENDATIONS, USING PERF-A-TAPE, JOINT CEMENT AND TOPPING. REINFORCE ALL EXTERNAL CORNERS WITH STANDARD GALVANIZED CORNER BEADS WITH 1" WINGS. PROVIDE NO. 300 PREF-A TRIM WHERE SHEET ROCK STOPS AGAINST MASONRY WALLS. FINISHED SURFACE SHALL BE SMOOTH AND UNIFORMLY FLAT. SECTION 9B, PAGE 1 OF 1 SECTION 15A. PLUMBING 15A-1. GENERAL CONDITIONS: THE CONTRACTOR SHALL BE FAMILIAR WITH ALL DIVISIONS OF THE WORK TO ASSURE PROPER COORDINATION. 15A-2. SCOPE OF THE WORK: (A) THE WORK COVERED BY THIS SECTION CONSISTS OF PROVIDING ALL MATERIALS, LABOR, AND EQUIPMENT REQUIRED FOR A COMPLETE PLUMBING INSTALLATION. THE WORK INCLUDES, BUT IS NOT LIMITED TO THE FOLLOWING ITEMS: 1. COLD WATER SUPPLY PIPING 2. SOIL, WASTE AND VENT PIPING 3. HOSE BIBBS 4. WATER HEATERS AND HOT WATER PIPING 5. ALL METERS 6. TEMPORARY SERVICE CONNECTIONS (B) THE ENTIRE WORK MUST BE EXECUTED IN A NEAT AND WORKMANLIKE MANNER, ACCORDING TO THE TRUE INTENT AND MEANING OF THE SPECIFICATIONS. EVEN THOUGH EVERY ITEM OF THE WORK OR MATERIALS INVOLVED IS NOT SHOWN ON THE DRAWINGS, THE CONTRACTOR SHALL FURNISH SAME FOR A COMPLETE SYSTEM. (C) ALL WORK DONE UNDER THIS PORTION OF THE CONTRACT SHALL BE IN STRICT ACCORDANCE WITH THE APPLICABLE DIVISIONS OF THE PLUMBING CODE IN EFFECT IN THIS LOCALITY. NOTHING IN THESE SPECIFICATIONS OR PLANS SHALL VOID THE REQUIREMENTS OF MEETING THE PLUMBING REGULATIONS OF THIS CITY. (D) THE CONTRACTOR FOR THE PLUMBING WORK SHALL FURNISH ALL TOOLS, MACHINERY, HOISTS AND OTHER MEANS OF PROPER HANDLING OF THIS WORK. 15A-3. PERMITS: THE CONTRACOR SHALL SECURE AND PAY FOR ALL PERMITS AND INSPECTIONS BY THE CITY, COUNTY AND STATE AUTHORITIES WHICH ARE REQUIRED IN CONECTION WITH THIS WORK. 15A-4. PLANS AND SPECIFICATIONS: THE CONTRACTOR MUST CHECK ALL MEASUREMENTS AND LOCATIONS OF PIPE, FITTINGS AND EQUIPMENT WITH THE DETAIL AND ARCHITECTURAL DRAWINGS AND LAY OUT HIS WORK AT THE BUILDING SO THAT ALL PARTS OF HIS WORK WILL FIT IN WITH OTHER PARTS OF THE BUILDING. BEFORE SUBMITTING PROPOSALS, EACH BIDDER SHALL VISIT THE SITE AND FULLY FAMILIARIZE HIMSELF WITH ALL JOB CONDITIONS AND SHALL BE FULLY INFORMED AS TO THE EXTENT OF HIS WORK. NO CONSIDERATION WILL BE GIVEN AFTER BID OPENING DATE FOR ALLEGED MISUNDERSTANDING AS TO THE REQUIREMENTS OF WORK INVOLVED IN CONNECTING TO THE EXISTING PIPES OR AS TO REQUIREMENTS OF MATERIALS TO BE FURNISHED. SECTION 15A, PAGE 1 OR 4 15A-5. EXCAVATION, TRENCHING AND BACKFILLING: (A) DO ALL EXCAVATING NECESSARY FOR SANITARY SEWERS, STORM DRAINS, WATER SUPPLY PIPING, GAS PIPING, ETC. BACKFILL ALL SUCH TRENCHES AND EXCAVATIONS AFTER WORK HAS BEEN INSTALLED AND TESTED, REMOVING ALL SURPLUS EARTH TO SUCH POINT AS MAY BE DIRECTED. EXCAVATION SHALL BE KEPT FREE FROM WATER BY PUMPING IF NECESSARY. (B) SEWER AND DRAIN TRENCHES WILL BE MADE TRUE TO GRADE BY MEANS OF SUBSTANTIAL AND ACCURATELY SET BATTER -BOARDS NOT MORE THAN FIFTY (50) FEET APART WITH A TAUT CORD OR WIRE STRETCHED BETWEEN THEM. CARE WILL BE EXERCISED TO INSURE THAT THE PIPE IS BEDDED ON UNDISTURBED EARTH OR SB2. (C) IN AREAS COVERED BY SLAB OR PAVING, THE SEWER OR WATER PIPE TRENCH WILL BE CAREFULLY BACKFILLED WITH EARTH FREE FROM BRICK, ETC., TO A DEPTH OF ONE-HALF THE PIPE DIAMETER AND THEN FIRMLY PUDDLED AND TAMPED IN SUCH A MANNER AS NOT TO DISTURB THE ALIGNMENT OR JOINTS OF THE PIPE. THEREAFTER, THE BACKFILL SHALL BE PUDDLED AND TAMPED EVERY VERTICAL FOOT. NO CLODS, BRICK, STONES, ETC., SHALL BE PLACED IN THE TRENCH UNTIL THE PIPE HAS ONE FOOT COVER. 15A-6. WORKMANSHIP: ALL WORKMANSHIP PERFORMED UNDER THIS SECTION SHALL BE EXECUTED IN A FIRST CLASS MANNER IN ACCORDANCE WITH -THE BEST PRACTICES OF THE TRADE. 15A-7. QUALITY OF MATERIALS: ALL MATERIALS AND FIXTURES USED IN THIS WORK SHALL BE FIRST GRADE IN EVERY RESPECT. ALL PIPE AND FITTINGS SHALL CONFORM TO THE ASTM STANDARD SPECIFICATIONS FOR PIPE OF EACH MATERIAL 15A-8. SANITARY PIPING: (A) A SYSTEM OF SOIL, WASTE AND VENT PIPING SHALL BE FURNISHED AND INSTALLED, CONNECTING ALL PLUMBING FIXTURES, EQUIPMENT AND -FLOOR DRAINS TO THE CITY SEWER. (B) VENT FLASHING: VENTS EXTENDING THROUGH THE ROOF SHALL BE FLASHED WITH SHEET LEAD WEIGHING NOT LESS THAN 4 LBS. PER SQUARE FOOT. THE BASE OF THE FLASHING SHALL NOT BE LESS THAN 18" X 18". FLASHING SHALL BE COORDINATED WITH THE ROOFING CONTRACTOR. (C) CLEANOUTS: PROVIDE ACCESSIBLE CLEANOUTS OF FULL OPENING WITH BRASS PLUG COVER, AT ENDS OF SOIL LINES, AT CHANGE OF DIRECTION AND WHERE SHOWN ON DRAWINGS. CLEANOUTS IN FLOORS SHALL BE ZURN NO. A-1326, OR APPROVED EQUAL. CLEANOUTS IN WALLS SHALL BE ZURN NO. Z-1320, OR APPROVED EQUAL, WITH STAINLESS STEEL COVER PLATES. 15A-9. COLD WATER PIPING: (A) CONNECT TO THE CITY WATER MAIN, INSTALL METER AS INDICATED OR REQUIRED AND EXTEND COLD WATER PIPING TO THE BUILDING AND TO ALL PLUMBING FIXTURES. (B) PAY ALL COSTS REQUIRED IN CONNECTION WITH THE WATER SERVICE AND SECTION 15A, PAGE 2 OF 4 METER INSTALLATION. (C) HOT AND COLD WATER PIPING SHALL BE AS FOLLOWS: COPPER TUBING SHALL BE USED FOR ALL HOT AND COLD DOMESTIC WATER LINES. TYPE "L" TUBE SHALL BE USED ABOVE THE GROUND AND TYPE "K" TUBE SHALL BE USED BELOW THE GROUND FLOOR SLAB. SWEAT FITTINGS MAY BE EITHER CAST BRASS OR WROUGHT COPPER. SOLDER JOINTS SHALL BE CLEANED WITH STEEL WOOL OR EMERY CLOTH BEFORE APPLYING SOLDERING PASTE (FLUX). 15A-10. PIPE COVERING: (A) ALL COLD WATER PIPING SHALL BE INSULATED WITH OWENS-CORNING PREFORMED FIBERGLASS OR GUSIN-BASON EXPANDED NEOPRENE FOAM PIPE COVERING, 3/4" THICK. COLD WATER COVERING SHALL HAVE JOINTS OF JACKETS SEALED WITH VAPOR BARRIER ADHESIVE AND JOINT SEALER STRIPS. (B) FITTING INSULATION SHALL BE OF FIBERGLASS, OR EXPANDED FOAM, MITERED TO FIT SNUGLY. 15A-11. WALL, FLOOR AND CEILING PLATES AND EXPANSION: (A) FLOOR, WALL AND CEILING PLATES: ALL PIPES PASSING THROUGH THE FLOORS, WALLS, OR CEILINGS OF FINISHED ROOMS SHALL BE FITTED WITH CHROME PLATED BRASS FLOOR, WALL OR CEILING PLATES SECURELY FASTENED IN PLACE. (B) EXPANSION: PROVIDE FOR EXPANSION AND CONTRACTION TO ALL PIPING AND MAKE PROPER PROVISIONS SO THAT THERE WILL BE NO UNDUE STRAIN ON ANY OF THE PIPING OR ANY PART OF THE WORK. 15A-12. FLOOR DRAINS: (A) FLOOR DRAINS SHALL BE PROVIDED WHERE SHOWN ON THE DRAWINGS, AND SHALL HAVE CAST IRON TRAPS AND PERFORATED OR SLOTTED.STRAINERS WITH OUTLETS THE SAME SIZE AS THE WASTE PIPE TO WHICH THEY ARE CONNECTED. THEY SHALL BE PROVIDED WITH TEMPORARY CLOSURES DURING CONSTRUCTION TO PREVENT STOPPAGE OF THE LINES. (B) FLOOR DRAINS SHALL BE JOSAM SERIES 300 OR EQUAL, WITH CAST IRON BODY AND NIKALOY STRAINER WITH RIM TO MATCH. (C) EACH FLOOR DRAIN WHERE WATERPROOFING MEMBRANES ARE PROVIDED SHALL HAVE A CLAMPING OR CAULKING COLLAR FOR MAKING A WATERTIGHT CONNECTION BETWEEN THE DRAIN AND THE MEMBRANE. 15A-13. PROTECTION OF FIXTURES: IMMEDIATELY AFTER SETTING OF ANY FIXTURE, EQUIPMENT, FITTINGS OR PIPING, PROTECT IT ADEQUATELY AGAINST DAMAGE. BE RESPONSIBLE FOR ALL FIXTURES, EQUIPMENT AND PIPING UNTIL THEY ARE ACCEPTED BY THE OWNER. AT ALL STAGES OF INSTALLATION, PIPE OPENINGS, FIXTURES AND EQUIPMENT MUST BE PROTECTED AGAINST THE ENTRANCE OF FOREIGN MATERIALS. ALL WATER AND GAS PIPING SHALL BE WELL REAMED AFTER CUTTING AND THOROUGHLY CLEANED OUT BEFORE ASSEMBLY SECTION 15A, PAGE 3 OF 4 15A-14. SUPPORTS AND HANGERS: HORIZONTAL SOIL WASTE AND VENT PIPING, EXCEPT THAT RESTING ON SOLID NATURAL GROUND, SHALL BE SUPPORTED NEAR THE JOINTS AT INTERVALS OF NOT OVER FIVE FEET. HORIZONTAL -WATER AND GAS PIPING SUSPENDED FROM BUILDING CONSTRUCTION SHALL BE SUPPORTED AT INTERVALS OF NOT MORE THAN EIGHT FEET. 15A-15. TESTS: INACCORDANCE WITH LOCAL CODES OR AS FOLLOWS: (A) ALL TESTS SHALL BE PERFORMED AS FOLLOWS: 1. ALL OPENINGS SHALL BE PLUGGED TIGHT, THE ENTIRE SYSTEM FILLED WITH WATER TO THE POINT OF OVERFLOW AND HELD FOR AT LEAST ONE HOUR BEFORE THE INSPECTION AND SHALL REMAIN FULL DURING THE TEST WITHOUT LEAKAGE. EACH VERTICAL STACK WITH ITS BRANCHES MAY BE TESTED SEPARATELY, BUT IN NO CASE SHALL ANY PORTION OR PART BE TESTED WITH LESS THAN A TEN FOOT HEAD OF WATER. 2. TEST OF WATER SUPPLY SYSTEMS: DISCONNECT AND CAP ALL OUTLETS TO PLUMBING FIXTURES AND ALL OTHER EQUIPMENT NOT DESIGNED FOR THE FULL TEST PRESSURE. FILL THE SYSTEM WITH WATER AND AFTER CHECKING TO SEE THAT ALL TRAPPED AIR IS ELIMINATED FROM THE SYSTEM, APPLY A HYDROSTATIC PRESSURE OF 100 LBS. PER SQUARE INCH. HOLD THE TEST PRESSURE UNTIL INSPECTION IS COMPLETED. ALL PIPING THROUGHOUT SHALL BE TIGHT UNDER TEST. 3. TEST OF GAS SYSTEM: APPLY TWENTY-FIVE (25) PSI AIR TEST FOR A TWENTY-FOUR HOUR PERIOD WITHOUT PRESSURE LOSS THROUGH LEAKAGE. 15A-16. CLEANING AND ADJUSTING: UPON COMPLETION OF WORK, CLEAR ALL DRAINS, TRAPS, PIPE LINES AND PLUMBING FIXTURES, ADJUST ALL VALVES, PACK STUFFING BOXES, REMOVE ALL RUBBISH AND LEAVE ALL WORK IN A FINISHED, CLEAN AND SATISFACTORY CONDITION. 15A-17. GUARANTEE: THE PLUMBING CONTRACTOR SHALL GUARANTEE HIS WORK AND SHALL MAKE GOOD WITHOUT COST TO THE OWNER ANY DEFECTS IN MATERIALS OR WORKMANSHIP WHICH MAY DEVELOP WITHIN THE PERIOD OF ONE YEAR FROM THE DATE OF COMPLETION AND ACCEPTANCE OF THE WORK BY THE OWNER. DEFECTS OF ITEMS FURNISHED BY THE OWNER ARE NOT INCLUDED IN THE GUARANTEE. 15A-18. PLUMBING FIXTURES (A) INSTALL ALL FIXTURES INDICATED, LISTED OR SPECIFIED AND FIXTURES AND FITTINGS NECESSARY TO COMPLETE THE SYSTEM, WHETHER SPECIFICALLY MENTIONED OR NOT, IN ACCORDANCE WITH THE DRAWINGS AND SPECIFICATION. CONNECT ALL FIXTURES AND EQUIPMENT, DRAINS, ETC., EXCEPT AS OTHERWISE SHOWN OR SPECIFIED, TO SUPPLY LINES AND WASTE AND VENT LINES. ROUGH -IN FOR ALL FIXTURES, FITTINGS, EQUIPMENT, ETC., AS SHOWN ON THE DRAWINGS, WHETHER FURNISHED UNDER THIS CONTRACT OR NOT. SECTION 15A, PAGE 4 OF 4 SECTION 15B HEATING, VENTING & AIRCONDITIONING 15B-1 THE WORK: THE WORK OF THIS SECTION SHALL INCLUDE COMPLETE HEATING, YEAR-ROUND AIR CONDITIONING AND VENTILATION SYSTEMS, INCLUDING THE FURNISHING AND INSTALLATION OF THERMOSTATS. THE WORK SHALL CONFORM WITH ALL MUNICIPAL, STATE AND FEDRAL REGULATIONS AFFECTING THE WORK AND TO THE NATIONAL BOARD OF FIRE UNDERWRITERS AND THE ARKANSAS INSPECTION AND RATING BUREAU. ALL MATERIALS SHALL BE NEW AND ALL MATERIALS AND WORKMANSHIP SHALL BE GUARANTEED FOR A PERIOD OF ONE YEAR FROM THE DATE OF ACCEPTANCE OF THE ENTIRE PROJECT. THE ELECTRICAL SYSTEM SHALL BE 3 WIRE, SINGLE PHASE, 120/240 VOLTS, 60 CYCLE, ALTERNATING CURRENT. ARRANGE DUCT WORK GENERALLY AT SHOWN ON MECHANICAL PLAN. GET OWNERS APPROVAL OF PROPOSED CHANGES. AUTOMATIC CONTROLS SHALL PROVIDE HEATING AND COOLING AT THE APPROPRIATE SEASON AND SHALL ALSO BE SO ARRANGED THAT VENTILATION CAN BE OBTAINED AT ALL TIMES. THE SYSTEM SHALL BE COMPLETE WITH ELECTRIC CONTROL SYSTEM, OPERATION SHALL BE AUTOMATIC, NOISELESS, PERFECT IN CIRCULATION AND OF AMPLE CAPACITY TO HEAT AND COOL ALL ROOMS AND PASSAGES. EQUIPTMENT SHALL BE SUPPLIED WITH FILTER GRILLS, SHALL HAVE AN EXPANSION VALVE ON THE COOLING COIL, VALVES ON BOTH SIDES OF THE COMPRESSOR, TIME GUARD CIRCUIT TO PREVENT RECYCLING OF THE COMPRESSOR IN PERIODS SHORTER THAN 5 MINUTES, SIGHT GLASS AND MOISTURE INDICATOR, A SUBCOOLING EFFECT IN THE CONDENSOR AND THE REFRIGERANT SHALL BE R-22 OR EQUAL. INSULATE SUCTION LINE WITH 3/4" "RUBATER" OR EQUAL. DUCTWORK SHALL BE COMPLETE WITH GRILLES, REGISTERS, DIFFUSERS, DEFLECTION DEVICES, TURNING VANES, CONTROLLING DEVICES, SPLITTERS, ETC.. GRILLES SHALL BE ADJUSTABLE AND VOLUME CONTROLABLE. INSULATE WITH MINIMUM 2 LB DENSITY. FABRICATE DUCTS INACCORDANCE WITH ASHRAE GUIDE, LATEST EDITION. ALL EQUIPMENT IS TO BE INSTALLED IN STRICT ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS SUPPLIED WITH THE UNITS. PAGE 1 OF 1 SECTION 16A ELECTRICIAL 16A-A CODES: ALL WORK SHALL CONFORM TO THE NATIONAL ELECTRICAL CODE, LATEST EDITION, AND THE NATIONAL ELECTRICAL SAFETY CODE WHEN NOT IN CONFLICT WITH LOCAL CODES OR ORDINANCES. PAY ALL FEES REQUIRED BY GOVERNING INSPECTING AGENCY. PROVIDE CERTIFICATES OF APPROVAL FROM INSPECTION AGENCY. 16A-2 EXTENT: PROVIDE ALL ITEMS REQUIRED FOR A COMPLETE OPERATING ELECTRICAL SYSTEM. 16A-3 SHOP DRAWING: SUBMIT 4 BROCHURES OF SHOP DRAWINGS AND DESCRIPTIVE DATA OF ALL MATERIAL, EQUIPMENT AND FIXTURES FOR APPROVAL WITHIN 15 DAYS AFTER CONTRACT IS LET. 16A-4 MATERIALS AND WORKMANSHIP: MATERIALS SHALL BE NEW AND LISTED BY UNDERWRITERS LABORATORIES, INC. ALL WORK SHALL BE EXECUTED IN WORKMANLIKE MANNER AND PRESENT NEAT AND MECHANICAL APPEARANCE WHEN COMPLETED. 16A-5 EXCAVATION AND BACKFILL: REFER TO SECTION 2A, SITEWORK. 16A-6 CUTTING AND PATCHING: LAY OUT ALL OPENINGS, RECESSES, CHASES AND INSTALL ALL SLEEVES AS WORK PROGRESSES. CUTTING AND PATCHING REQUIRED DUE TO INACCURACIES, DELAY IN LOCATION OR OMMISSION SHALL BE ACCOMPLISHED BY THE PARTICULAR TRADE INVOLVED AT THIS CONTRACTORS EXPENSE. 16A-7 WORK AND MATERIALS: A. CONTROL WIRING BY MECHANICAL CONTRACTOR. B. STARTERS, MOTORS, VALVES, ETC. FOR MECHANICAL EQUIPMENT SHALL BE FURNISHED BY MECHANICAL CONTRACTOR FOR INSTALLATION BY ELECTRICAL CONTRACTOR. C. FURNISH ALL MATERIALS FOR AND MAKE POWER CONNECTIONS TO MECHANICAL EQUIPMENT. 16A-8 TEMPORARY WIRING: FURNISH ALL TEMPORARY WIRING FOR POWER AND LIGHTING. 16A-9 MAIN SERVICE DISTRIBUTION: PROVIDE MAIN DISCONNECT SWITCH AND DISTRIBUTION PANEL EQUAL TO GENERAL ELECTRIC, WESTINGHOUSE OR SQUARE-D. PROVIDE SWITCHES IN ACCORDANCE WITH LOCAL POWER COMPANY. 16A-11 PANELS: SHALL HAVE PERMANENT CIRCUIT MARKINGS AND TYPE WRITTEN DIRECTORY CARDS SHOWING EQUIPMENT AND AREAS CONTROLLED BY BRANCH CIRCUTS. 16A-12 FUSES: FURNISH COMPLETE SET OF BUSS FUSETRONS FOR ALL FUSIBLE SWITCHES. 16A-13 WIRING: INSTALL RIGID GALVANIZED STEEL CONDUIT OR ELECTRICAL SECTION 16A, PAGE 1 OF 2 METALLIC TUBING WITH CONDUCTORS OF TYPE AND SIZE PER N.E.C.. NON-METALLIC SHEATHED CABLE MAY BE USED WHERE ALLOWED BY LOCAL REGULATIONS (CONFIRM PRIOR TO BIDDING). WIRING SHALL BE COPPER 600V INSULATED AS APPROPRIATE. WIRE SHALL BE NATIONAL, SIMPLEX, ANACONDA OR EQUAL. 16A-14 BRANCH CIRCUT WIRING: CONNECT TO PANEL BOARD TO GIVE EVENLY BALANCED LOAD TO FEEDER SUPPLYING THE PANEL BOARD. 16A-15 OUTLET BOXES (CONCEALED): FLUSH MOUNTED WITH SURFACE APPROPRIATELY SIZED FOR INTENDED PURPOSE, MADE OF GALVANIZED OR SHERARDIZED SHEET STEEL, EQUAL TO APPLETON, STEEL CITY OR RACO. 16A-16 WIRING DEVICES: EQUAL TO ARROW -HART, BRYANT, HUBELL, SIERRA, OR PASS AND SEYMOUR. DO NOT INSTALL DEVICES UNTIL WORK LIKELY TO DEFACE OR DAMAGE IS COMPLETE. IVORY COLOR UNLESS SHOWN OTHERWISE ON DRAWINGS. A. RECEPTACLES: BAKELITE, 15 AMP, 125 VOLTS WITH GROUNDING TERMINALS. UNLESS SHOWN OTHERWISE ON DRAWINGS MOUNT 18" ABOVE FLOOR. B. WALL SWITCHES: SPECIFICATION GRADE, BAKELITE, 15 AMP, 120-277 VOLT AC. UNLESS OTHERWISE SHOWN MOUNT 4'-00 ABOVE FLOOR. C. PLATE: APPROPRIATE FOR TYPE AND SIZE OF OUTLET. TWO OR MORE DEVICES IN SAME LOCATION SHALL BE COVERED WITH SINGLE PLATE OF PROPER GANG. 16A-17 LIGHTING FIXTURES: FURNISH AND INSTALL SCHEDULED LIGHT FIXTURES. END PLATES, JOINTING PLATES, STEMS, PLASTER RING AND ALL APPURTENANCES NECESSARY FOR A COMPLETE INSTALLATION SHALL BE FURNISHED AND INSTALLED AS IF SPECIFICALLY SPECIFIED. A. FLUORESCENT FIXTURES: BALLAST -HIGH POWER FACTOR, CLASS_ P, E.T.L. APPROVED AND BI-PIN RAPID START TUBES. TUBES: DAYLIGHT COLOR UNLESS SHOWN OTHER WISE ON DRAWINGS. B. LAMPS: AS MANUFACTURED BY WESTINGHOUSE, SYLVANIA OR GENERAL ELECTRIC CO. C. SUPPORT: PROVIDE ADEQUATE SUPPORT FOR LIGHTING FIXTURES. 16A-18 METERING: OBTAIN FROM LOCAL UTILITY COMPANY METERING EQUIPMENT AND INSTALL IN ACCORDANCE WITH LOCAL REQUIREMENTS. MATERIAL AND LABOR NOT PROVIDED BY LOCAL UTILITY CO. SHALL BE PROVIDED BY ELECTRICAL CONTRACTOR. SECTION 16A, PAGE 2 OF 2 I I I J u 1 I 1 C