Loading...
HomeMy WebLinkAboutZ-7067 Staff AnalysisJuly 26, 2001 ITEM NO.: 11 FILE NO.: Z-7067 NAME: Ensco Parkhill (Lot 3R, Phase 2) - Conditional Use Permit LOCATION: South side of Corporate Hill Drive, south of West Markham Street n7V M0PER: ENGINEER: Markham Street Development Bartlett and West Engineers, Inc. 2226 Cottondale Lane 1701 Centerview, Suite 210 Little Rock, AR 72202 Little Rock, AR 72211-4312 AREA: 2.31 acres ZONING: O-2 NUMBER OF LOTS: 1 FT. NEW STREET: 0 ALLOWED USES: Office PROPOSED USE: Hotel VARIANCES/WAIVERS REQUESTED: A variance to allow increased building height. A. PROPOSAL/REQUEST: The applicant, Markham Street Development, requests a conditional use permit to allow construction of a hotel on the 0 -2 -zoned property along the south side of Corporate Hill Drive (Lot 3R, Phase 2, Ensco Parkhill Addition). The development will consist of a three-story hotel building with approximately 35,000 square feet of building area and 70 guest rooms. There will be a total of 81 parking spaces to serve the hotel development. There are 24 existing parking spaces on Lot 3R, Phase 2, Ensco Parkhill Addition which were constructed as part of the office development to the west on Lot 2R. There are cross -access easements between the two (2) lots. The new parking on Lot 3R will tie into the existing parking lot. July 26, 2001 ITEM NO.: 11 (Cont.) FILE NO.: Z-7067 There will be two (2) access points from Corporate Hill Drive and one (1) access through Lot 2R to the west. There will be a small amount of parking along the north side of the building, with a driveway along the building's east side to access the parking in the rear. The height of the main hotel building will be approximately 43 feet (mean height of the sloped roof), with the height of the proposed tower feature being 62 feet to the peak of the roof. The maximum height allowed in 0-2 zoning is 45 feet, up to 120 feet with increased building setbacks. The applicant has requested a variance for the increased building height of the tower structure. The applicant has submitted a south building elevation showing the tower feature. B. EXISTING CONDITIONS: The property is undeveloped and wooded. There are existing office buildings to the east, west and north across Corporate Hill Drive. Interstate 630 is located to the south. C. NEIGHBORHOOD COMMENTS: The Treasure Hills and Santa Fe Heights Neighborhood Associations were notified of the public hearing. As of this writing, staff has received one (1) phone call from a person requesting information on this application. D. ENGINEERING COMMENTS: E PUBLIC WORKS CONDITIONS: 1. Property frontage needs to have the sidewalks and ramps brought up to the current ADA standards. 2. Repair or replace any curb and gutter or sidewalk that is damaged in the public right-of-way prior to occupancy. 3. All driveways shall be concrete aprons per City Ordinance. 4. Plans of all work in right-of-way shall be submitted for approval prior to start of work. 5. Stormwater detention ordinance applies to this property. UTILITIES AND FIRE DEPARTMENT/COUNTY PLANNING: Wastewater: Sewer available, not adversely affected. Capacity Contribution Analysis Required. Contact Little Rock Wastewater Utility for details. 2 July 26, 2001 ITEM NO.: 11 (Cont.) FILE NO.: Z-7067 Entergy: No Comment. ARKLA: No Comment received. Southwestern Bell: No Comment. Water: If there are facilities that need to be adjusted and/or relocated, contact Central Arkansas Water. That work would be done at the expense of the developer. An acreage charge of $150/acre applies in addition to the normal connection charge for this parcel. (2.3 acres @150/acre - $345.00). Fire Department: Private fire hydrants may be required. Contact Dennis Free at 918-3752 for details. County Planning: No Comment received. CATA: Project site is located on bus route #5, but has no effect on bus radius, turnout and route. F. Landscape Issues: The plan submitted does not allow for the average on-site street buffer width required along Corporate Hill Dr. of 24 feet. An irrigation system to water landscaped areas will be required. The interior landscape islands within the proposed northern parking lot are 270 square feet short of the 8% (672 sq. ft.) required by the Landscape Ordinance. G. SUBDIVISION COMMITTEE COMMENT: (JULY 5, 2001) Thomas Graham was present, representing the application. Staff briefly described the conditional use permit, noting that some additional information was needed. Staff noted that a variance needed to be requested for the proposed building's tower feature. The Public Works requirements were briefly discussed. Public Works representatives noted that the slope of the driveway along the east property line must not exceed 12 percent. 3 July 26, 2001 ITEM NO.: 11 (Cont.) FILE NO.: Z-7067 The landscaping issues were also discussed. Bob Brown, of the Planning Staff, noted that the street buffer along Corporate Hill Dr. should average 24 feet. Mr. Graham noted that the site plan would be revised accordingly. After the discussion, the Committee forwarded the application to the full Commission for final action. H. ANALYSIS: The applicant submitted a revised site plan to staff on July 11, 2001. The revised plan addresses all of the issues raised during the staff review and Subdivision Committee meeting. The building has been shifted back from Corporate Hill Drive and the street buffer now conforms to ordinance standards. Public Works has reviewed the revised site plan and notes no outstanding issues. As noted in paragraph A., the applicant is requesting a variance to allow increased building height for the tower structure at the southeast corner of the proposed hotel building. Based on the fact that this tower structure is as ornamental feature, staff has no problem with the variance as requested. There are 81 parking spaces proposed to serve the hotel use. The ordinance requires a minimum of 77 parking spaces. Staff also supports the parking plan as proposed. The proposed site plan shows a ground -mounted sign along Corporate Hill Drive at the property's easternmost access drive. The sign and any wall -mounted signage must not exceed the ordinance standards for office zoned property. Otherwise, to staff's knowledge there no outstanding issues associated with the conditional use permit. The proposed hotel should have no adverse impact on the general area. I. STAFF RECOMMENDATIONS: Staff recommends approval of the conditional use permit subject to the following conditions: 1. Compliance with the requirements as noted in paragraphs D, E and F of this report. 4 July 26, 2001 ITEM NO.: 11 (Cont.) FILE NO.: Z-7067 2. The proposed ground -mounted sign must not exceed the ordinance standards for office zoned property. 3. The dumpster area must be screened on three (3) sides with an eight (8) foot high opaque fence or wall. 4. Staff recommends approval of the variance for the increased building height of the building's tower feature. 5. The slope of the driveway along the property's east side must not exceed 12 percent. PLANNING COMMISSION ACTION: (JULY 26, 2001) Staff presented a positive recommendation on this application, as there were no further issues for resolution. There were no objectors to this matter present. The Chairman placed the item before the Commission for inclusion within the Consent Agenda for approval as recommended by staff. A motion to that effect was made. The motion passed by a vote of 8 ayes, 1 nay and 2 absent. 5 SUBDIVISION COMMITTEE COMMENTS JULY 5, 2001 ITEM 11 ENSCO PARKHILL (LOT 3R, PHASE 2) — C.U.P. (Z-7067) Planning Staff Comments: 1. Need to request a variance for reduced side yard setback (east side) or revise site plan to meet the minimum 25 -foot setback requirement. We will comply. 2. Note building heights on the site plan — request variance. We will comply. See Site Plan. 3. Parking required — 77 spaces. Parking proposed — 83 spaces. No response necessary. 4. Provide elevations showing tower feature. We will comply. See Attached. 5. Any dumpster area must be shown on the site plan with required screening. See Site Plan 6. Any fencing must be shown on the site plan with details (type and height). No fencing on site. 7. Provide ground -mounted sign details (height and area). Sign must be setback at least 5 feet from any property line. We will comply. See Attached. Variance/Waivers: None requested. Public Works: 1. Property frontage needs to have the sidewalks and ramps brought up to the current ADA standards. We will comply. 2. Repair or replace any curb and gutter or sidewalk that is damaged in the public right-of-way prior to occupancy. We will comply. 3. All driveways shall be concrete aprons per City Ordinance. We will comply. 4. Plans of all work in right-of-way shall be submitted for approval prior to start of work. We will comply. 5. Storm water detention ordinance applies to this property. We will comply. Utilities and Fire De artment/Coun Planning: Wastewater: Sewer available, not adversely affected. Capacity Contribution Analysis Required. Contact Little Rock Wastewater Utility for details. No response necessary. Entergy: No Comment. No response necessary. ARKLA: No Comment received. No response necessary. Southwestern Bell: No Comment. No response necessary. Water: If there are facilities that need to be adjusted and/or relocated, contact Central Arkansas Water. That work would be done at the expense of the developer. An acreage charge of $150/acre applies in addition to the normal connection charge for this parcel. (2.3 acres @ 150/acre - $345.00). We will comply. Fire Department: Private fire hydrants may be required. Contact Dennis Free at 918-3752 for details. We will comply if necessary. County Plannin : No Comment received. No response necessary. F:\13000\13113.000\Corres\received\SUBDIVISION COMMITTEE COMMENTS.doc CATA: project site is located on bus route #5, but has no effect on bus radius, turnout and route. No response necessary. Landscape: The plan submitted does not allow for the average on-site street buffer width required along Corporate Hill Dr. of 24 feet. See Site Plan. An irrigation system to water landscaped areas will be required. We will comply. The interior islands within the proposed northern parking lot are 270 square feet short of the 8% (672 sq. ft.) required by the Landscape Ordinance. See Site Plan. Revised Site Plan: Submit four (4) copies of a revised site plan and the additional information as requested to staff no later than Wednesday, July 11, 2001. F:\13000\13113.000\Corres\received\SUBDIVISION COMMITTEE COMMENTS.doc