HomeMy WebLinkAboutZ-6964 Map 4W
E
10
to
M
co
0
a
I
n
N
O+
a
00
m
EXTEND ALUCOBOND PANEL
DOWN PARAPET WALL EXTEND
BASE FLASHING UP BEHIND
VULCRAFT DECK TYPE 1.513-1890.
OR 3" DECK - 22ga.
W 8X18 —
ALUCOBOND BEAM BEYOND
. A
N
BTM OF DECK
0 11'-6" A.F.F.
ro
I
N I
-IN -
NEW 24ga. PREFINISHED
FLASHING BEYOND
SAWCUT EXST. BRICK
INSTALL 24ga. FLASHING —
MODIFIED BITUMEN ROOF W
3 LAYERS TAPERED INSULA
VULCRAFT DECK TYPE
1.5-18ga. OR 3" DECK
0 22ga.
W 8X18
EXISTING BRICK TO REMAIN
3-5/8" MT'L STUDS
BRACE AS REQUIRED
1/2" EXTERIOR GRADE
PLYWD, 0 BTM. OF STUDS
10"
1'-0"
9.,
3-5/8" 20go. MT'L STUDS COORD.
EXACT POSTITION W/ ALUCOBOND
REQUIREMENTS
1/2" EXTERIOR GRAff PLYWOOD
WRAP BOTTOM OF STUDS
ALUCOBOND PANEL REFER
TO MFGR. FOR INSTALLATION
SLOPE Ah I SLOPE
/ I I
I I
I I
� I
'-0'! ALUCOBOND
COLUMN BEYOND
WALL SECTION @ ENTRANCE
1 " - V-0..
SLOPE
ALUCOBOND PANELS REFER
TO MFGR. FOR INSTALLATION
WALL SECTION @ ENTRANCL_
D
A2.1
1" = 1'-0"
V
BTM OF DECK
0 11'-6" A.F.F.
m
I
10'-0" A.F.F.
E.J.
L
2'-0"
EXTERIOR ROOF DRAIN
INTERIOR DOWNSPOUT DRAIN TO (N) COLUMN
3-5/8" UT'L STUDS 0 16"O.C.
BRACE AS REQUIRED
MODIFIED BITUMEN ROOF W/ 3
LAYERS TAPERED INSULATION
SLOPE TO ROOF DRAIN
EXISTING STRUCTURE TO REMAIN
PROVIDE (N) 24ga. FLASHING W/
HEMMED EDGES ON TOP OF (E)
GUTTER EXTEND TO BASE FLASHING
EXST. GUTTER & DOWNSPOUT
TO REMAIN
C 6X8.2 W/ 3/4" BOLTS 0 24"o.c.
ATTACH 3-5/8" MT'L STUDS
it 0 16"o.c. TO EXST. BRICK
II
00 LL:NEW ALUMINUM STOREFRONT ¢ g"
VERIFY W/ ARCHITECT EXACT
DESIGN OF DOORS BEFORE
INSTALLATION
COLUMN BLOCKOUT
CEILING TO REMAIN AS IS
REPAIR AS REQUIRED
5/8" GYP. BD. FURRDOWN
ON MT'L STUDS
DEMO EXISTING ENTRY DOORS
& FRAMES
PROVIDE 1/2" NON -TRACKING
\ E.J. SEALANT AT ALL JOINTS
i ALUCOBOND PANELS 0
2'-0" DIAMETER REFER
TO MFGR. FOR INSTALLATION
VARIES
BASE PLATE 1/2"X12"X12"
W/ (4) 3/4" ANCHOR BOLTS co
To
E.J.
-
COLUMN FOUNDATION BELOW �I
W 8X31 N
g,. 4" INTERIOR DOWNSPOUT
� DRAIN TO DAYLIGHT COORD.
W/ CONCRETE WORK N
/
1D' -O" A.F.F. ..
1'-6"
P COLUMN SECTION
2.1 _
9
1111l'i'll"ImilmSEIIM
son E III
somms;lm
R
I
N
�1
u
Mill
2'-O"
WALL SECTION @ ENTRANCE
B
2.1
1" = 1'-0"
TURN ALUCOBOND PANEL
INTO GUTTER OVER FLASHING
GUTTER WRAP W/ 24ga.
PREFINISHED FLASHING
KALWALL SYSTEM - INSTALL
PER MFGR. INSTRUCTIONS
3" CONT. PLATE W/ 1/4" PLATE
STIFFENER 0 24"o.c.
SINGLE PLY GUTTER OF EPDM
MATERIAL 3 SIDES CONTINUOUS
ON PERIMETER OF CANOPY
W 16X36
1/2" EXTERIOR GRADE PLYWOOD
WRAP OUTSIDE OF MT'L STUDS
& GUTTER
3-5/8" MT'L STUDS 0 16"o.c.
BRACE AS REQUIRED
ALUCOBOND PANELS REFER TO
MFGR. FOR INSTALLATION
CANOPY SECTION @ DROP OFF
E
2.1
KALWALL SYSTEM - INSTALL
PER MFGR. INSTRUCTIONS
(N) 24ga. FLASHING TIE INTO
EXST. GUTTER AND TURN UP
ONTO KALWALL STRUCTURE -
SEAL
TOP OF STEEL
0 12'-5-1/4" A.F.F.
W 12X14
3-5/8" MT'L STUDS 0 16"o.c.
BRACE AS REQUIRED
1/2" EXTERIOR GRADE PLYWOOD
WRAP BTM. OF MT'L STUDS
ALUCOBOND PANELS - INSTALL
PER MFGR. SUGGESTIONS
EXISTING STRUCTURE TO REMAIN
PAINT REVEAL
BAND RED TO
MATCH RED
METAL PANELS _
1 1/2" O NOTE:
PREFABRICATED CONCRETE BOLLARD.
EXPOSED WAUSAU TILE BOLLARD # TF6087
AGGREGATE 12" 0 x 60" MEDIUM GRAY W/
FINISHGRAY MATRIX AGGREGATE FINISH.
COLOR TO 1.-6" NJ BURY 2'-0" DEEP TYP.
MATCH BLDG.
BLOCK
NEW RAMP
LEAN CONCRETE o
OR FLOWABLE 1 z
BACKFILL N
ma�ao 0 _e, o
o GRAVEL
BASE
ENTRANCE BOLLARD DETAIL
2.1
3/4" = 1'-0'
m r.
ao
N
."4
V)
1 O
J _
Q
Ld
V)
REGISTL
7•
"ted
0
®�" �R1CAtaa��°"
®8'b®LOBS@
REVISIONS I DATE
RID ss
" f
t
1127-00
885A►
DATE
YI
U 0
00
A2.1
3
N
N
OF
Z
W n
J
O
V /
LAJ
w
W
12
Y_ZZ
=�N
Y Li. W0
o
o
LTJ L{J Lu U
n
3
wa.a.%-
QnU
W
I-1
W Q
HJ
J (/')
� Q
Z
QY
-i
W V
a-
LLJ
Q I—
0-
'rr
Fm-,
W
Q
V)
1 O
J _
Q
Ld
V)
REGISTL
7•
"ted
0
®�" �R1CAtaa��°"
®8'b®LOBS@
REVISIONS I DATE
RID ss
" f
t
1127-00
885A►
DATE
JOB NO.
A2.1
3
SHEET
OF