HomeMy WebLinkAboutZ-6915-C Staff AnalysisFILE NO.: Z -6915-C
NAME: Gamble Road Short -form PCD and Land Alteration Variance Request
LOCATION: Located on the Northwest corner of Chenal Parkway and Gamble Road
DEVELOPER:
Davis Properties
P.O. Box 241025
Little Rock, AR 72223
ENGINEER:
White-Daters and Associates
24 Rahling Circle
Little Rock, AR 72223
OR(`WTF(`T-
Terry Burruss, Architects
1202 South Main Street, Suite 230
Little Rock, AR 72202
AREA: 3.22 acres
CURRENT ZONING:
ALLOWED USES -
PROPOSED ZONING:
PROPOSED USE:
NUMBER OF LOTS: 2
PCD
FT. NEW STREET: 0
0-3, General Office District and C-3, General Commercial
District uses
Revised PCD
0-3, General Office District and C-3, General Commercial
District uses
ARIANCES/WAIVERS REQUESTED: None requested.
BACKGROUND:
A request to rezone the site from 0-3, General Office District to PCD was reviewed and
approved by the Little Rock Planning Commission at their March 8, 2001, Public
Hearing. This applicant requested staff not forward the item to the Board of Directors
FILE NO.: Z -6915-C (Cont.
for final action therefore the property remained zoned 0-3. The applicant proposed a
three -lot plat to consist of 0-3, General Office District permitted uses and a furniture
store.
The Planning Commission reviewed and approved a request for a preliminary plat of
this site at their May 26, 2005, Public Hearing. The applicant requested the subdivision
of 3.22 acres of 0-3, General Office District zoned property into two lots. The average
lot size proposed was 1.79 acre with Lot 1 being 1.23 acres and Lot 2 being 2.34 acres.
Proposed Lot 1 had street frontage to Chenal Parkway but was not allowed a driveway
access. A cross access and utility easement was approved to serve Lot 1.
Ordinance No. 19,455 adopted by the Little Rock Board of Directors on December 5,
2005, rezoned the site from 0-3, General Office District to PCD and established
Gamble Road Short -form PCD. The rezoning for Lot 2 to PCD allowed the
development of Gamble Road Plaza Center a three-story building with a lower level, a
main level and an upper level. The lower level would be used for office space and
some storage space. The main level was proposed for retail space and the upper level
containing office space.
The site was to be developed with approximately 12,000 square feet of retail space and
19,630 square feet of office space. The development was proposed as 62 percent
office utilizing 0-3, General Office District uses and 38 percent commercial utilizing C-3,
General Commercial District uses. The applicant indicated a furniture store was
proposed to locate on the site along with several office users. The furniture store would
have an area of showroom and display along with an area of warehousing.
The applicant proposed the right of way for Gamble Road be abandoned and access to
Rock Creek Park to the north preserved via an access and utility easement located
within the east 20 -feet of the existing right of way. Access to Lot 1 would be maintained
with an access easement for use of the existing driveway along the east side of Lot 1.
Ordinance No. 19,454 adopted by the Little Rock Board of Directors on December 5,
2005, abandoned the right of way for Gamble Road.
A. PROPOSAL/REQUEST:
The applicant is now seeking a rezoning of the site to allow the development of
the site in two phases with a single building constructed in each phase. The first
phase is proposed with the construction of a 6,000 square foot two story building
constructed for an office user. The second building is also proposed as a
two-story building with 20,300 square feet utilizing the ground level as retail and
the upper level as office spaces. The site plan includes 76 on-site parking
spaces to serve the development.
The applicant is also seeking a variance from the Land Alteration Ordinance to
allow advanced grading of the site. The applicant is seeking to grade the entire
site with the construction of the sites first building.
2
FILE NO.: Z -6915-C Cont.
B. EXISTING CONDITIONS:
The site contains an existing medical office building taking access from Gamble
Road (previously abandoned). There is an apartment complex located to the
west of the site. To the north of the site is the Rock Creek Floodway; an area
identified on the Parks Master Plan as recreational open space. The area to the
east of the site is zoned PCD and is a strip retail center. South of the site are
commercial uses located on C-3, General Commercial District zoned property.
C. NEIGHBORHOOD COMMENTS:
The Parkway Place Neighborhood Association, the Gibralter Heights
Neighborhood Association along with all property owners located within 200 -feet
of the site and all residents who could be identified located within 300 feet of the
site were notified of the public hearing. As of this writing staff has received one
informational phone call from an area resident.
D. ENGINEERING COMMENTS.
PUBLIC WORKS CONDITIONS:
1. A grading permit in accordance with Section 29-186 (c) and (d) will be
required prior to any land clearing or grading activities at the site. Site
grading, and drainage plans will need to be submitted and approved prior to
the start of construction. If the applicant plans to clear Phase 2 with
construction of Phase 1, a variance from the Land Alteration Regulations
must be requested.
2. A Sketch Grading and Drainage Plan will be required per Section 29-186
(e).
3. Storm water detention ordinance applies to this property. Show the
proposed location for storm water detention facilities on the plan.
4. If disturbed area is one (1) or more acres, obtain a NPDES storm water
permit from the Arkansas Department of Environmental Quality prior to the
start of construction.
5. A special Grading Permit for Flood Hazard Areas will be required per
Section 8-283 prior to construction.
6. Provide existing topographic information at maximum five-foot contour
interval. Show the limits of the 100 -year floodway and floodplain.
7. The minimum Finish Floor elevation is required to be shown on plat and
grading plans.
8. The median shown in the site plan is not drawn correctly. The intersection
has 2 thru lanes and a right turn lane.
3
FILE NO.: Z -6915-C
9. In accordance with Section 31-176, floodway areas must be shown as
floodway easements or be dedicated to the public. In addition, a 25 foot
wide access easement is required adjacent to the floodway boundary.
10. The abandoned right of way must be platted with a 20 foot access
easement to allow access to City owned property for maintenance. The
previous application showed the easement on the eastern side of the
abandoned right of way.
11. The proposed driveway into and out of proposed development must be
redesigned for a straight vehicular movement into and out of the
development and not require vehicles to jog left or right.
E. UTILITIES AND FIRE DEPARTMENT/COUNTY PLANNING:
Wastewater: Sewer available to the site. Sewer service for 13100 Chenal
Parkway may cross property involved in development. If so sewer main will be
required with easement to serve the existing building. Contact Little Rock
Wastewater Utility at 688-1414 for additional information.
Entergy: No comment received.
Center -Point Energy: No comment received.
AT & T: No comment received.
Central Arkansas Water: Contact Central Arkansas Water regarding the size
and location of the water meter. Additional fire hydrant(s) will be required.
Contact the Little Rock Fire Department to obtain information regarding the
required placement of the hydrant(s) and contact Central Arkansas Water
regarding procedures for installation of the hydrant(s). No signs, light poles, flag
poles or other objects with foundations will be allowed within the waterline
easement crossing this property. Extra care must be taken to protect the water
main within this easement.
Fire Department: Place and install fire hydrants per code. Contact the Little
Rock Fire Department for additional information.
County Planning: No comment.
CATA: The site is not located on a dedicated CATA Bus Route.
F. ISSUES/TECHNICAL/DESIGN:
Planning Division: This request is located in the Chenal Planning District. The
Land Use Plan shows Multi Family for this property. The applicant has applied
for a revised Planned Commercial Development to allow construction of two
buildings on the site.
CI
FILE NO.: Z -6915-C (Cont.
A Land Use Plan Amendment (LU01-19-01) to change this area to Mixed Use
was approved by the Planning Commission for this site on March 8, 2001, but
this amendment was never acted on by the Board of Directors. If the current
zoning item Z -6915-C is approved by the Planning Commission, this Land Use
Plan amendment will go to the Board of Directors along with the zoning item.
Master Street Plan: Chenal Parkway is shown as a Principal Arterial on the
Master Street Plan. This street may require dedication of right-of-way and may
require street improvements. The primary function of a Principal Arterial is to
serve through traffic and to connect major traffic generators or activity centers
within urbanized areas. Entrances and exits should be limited to minimize
negative effects of traffic and pedestrians since this is a Principal Arterial.
Bicycle Plan: A Class I bike route is shown north of this site according to the
Master Street Plan bicycle section. A Class I bikeway is built separate from or
alongside a road. Additional paving and right of way may be required.
City Recognized Neighborhood Action Plan: The applicants property lies in the
area covered by the Rock Creek Neighborhood Action Plan. The Park and
Recreation goal states: `Work with Parks and Recreation to develop open space
behind Target into a passive park system with access from Chenal Parkway
(via Gamble Road) and Markham Street" The Office and Commercial
Development goal states: "Aggressively use Planned Zoning Districts (PZDs) to
influence more neighborhood -friendly and better quality developments"
Landscape:
1. The site plan must comply with the Citys minimal landscape and buffer
ordinance requirements.
2. The zoning buffer ordinance requires a twenty-three foot (23) wide land use
buffer along the northern perimeter of the property. Seventy percent of this
area is to remain undisturbed.
3. The zoning buffer ordinance requires a twenty foot wide (20') land use buffer
along the western most portion of the property, next to the residentially zoned
areas. Seventy percent of this area is to remain undisturbed.
4. The zoning buffer ordinance requires a nine foot wide (9) land use buffer
along the western/southern portion of the site, next to the office zoned
property. Seventy percent of this area is to remain undisturbed.
5. The zoning street buffer requires an average twenty-three foot (23) wide
street buffer and in no point be less than half along Chenal Parkway.
6. A six (6) foot high opaque screen, either a wooden fence with its face side
directed outward, a wall, or dense evergreen plantings, is required along the
northern, western, and southern perimeters of the site, where located to areas
that are deemed less intensity uses by the City of Little Rock code. Credit
5
FILE NO.: Z -6915-C (Cont.
towards fulfilling this requirement can be given for existing trees and
undergrowth that satisfies this year -around requirement.
7. An automatic irrigation system to water landscaped areas will be required.
8. Prior to the issuance of a building permit, it will be necessary to provide an
approved landscape plan stamped with the seal of a Registered Landscape
Architect.
9. The City Beautiful Commission recommends preserving as many existing
trees as feasible on this site. Credit toward fulfilling Landscape Ordinance
requirements can be given when preserving trees of six (6) inch caliper or
larger.
G. SUBDIVISION COMMITTEE COMMENT: (July 26, 2007)
The applicant was present. Staff presented an overview of the proposed
development stating there were a number of technical issues associated with the
request remaining outstanding. Staff requested the applicant include a cross
access easement on the site plan to serve Lot 1. Staff also questioned the total
office and total commercial spaces proposed for the site. Staff questioned if the
developers were willing to limit the available square footage for restaurant use.
Staff stated the site was located within the Chenal Design Overlay District which
regulated signage and overhead utilities. Staff questioned the location for the
proposed signage including the total height and area and the total area for the
proposed building signage.
Public Works comments were addressed. Staff stated the driveway into the
proposed development must be realigned to provide straight vehicular movement
into and out of the development. Staff stated the abandoned right of way must
be platted as a 20 foot access easement to access City owned property for
maintenance. Staff questioned if the entire site would be cleared with the
development of Phase I. Staff stated if this was the case a variance from the
Land Alteration Ordinance would be required.
Landscaping comments were addressed. Staff stated a minimum street buffer of
23 -feet would be required along Chenal Parkway. Staff also stated a 20 -foot
land use buffer would be required along the western perimeter and 9 -foot along
the eastern perimeter. Staff stated an automatic irrigation system would be
required to water landscaped areas. Staff stated a landscape plan would be
required prior to the issuance of a building permit.
Staff noted comments from the various other reporting departments and
agencies suggesting the applicant contact them directly for additional information
and clarification. There was no further discussion of the item. The Committee
then forwarded the item to the full Commission for final action.
9
FILE NO.: Z -6915-C Cont.
H. ANALYSIS:
The applicant submitted a revised site plan to staff addressing most of the issues
raised at the ,duly 26, 2007, Subdivision Committee meeting. The revised plan
has not addressed staffs concerns related to vehicular access. Vehicles must
still jog left or right to enter or exit the development creating a traffic hazard.
Staff feels only a minor modification is necessary to remedy this situation and
recommends the entrance be redesigned with the assistance of the City Traffic
Engineer.
The site is proposed for development in two phases with a single building
constructed in each phase. The first phase is proposed with the construction of a
building footprint with 3,000 square feet and the structure being a two story office
building. The second building is proposed as a two story building with a
10,150 square foot building footprint utilizing the ground level as retail and the
upper level as office spaces. The maximum building height proposed is 30 -feet.
The request includes a limit of 20 percent of the gross floor area for a restaurant
user or 2,030 square feet.
The total building square footage proposed for the site is 26,300 square feet with
16,150 square feet designated for office space and 10,150 square feet for
commercial space. The site plan includes 76 on-site parking spaces to serve the
development. Based on typical minimum parking requirements a total of
40 parking spaces would be required to serve the proposed office use and 33 to
serve the commercial space. Based on a portion of the site being used for a
restaurant use 47 parking spaces would be required to serve the commercial
portion of the development or 20 spaces for the restaurant and the remainder to
serve potential commercial users. Based on the maximum intensity of uses a
total of 80 parking spaces would typically be required for the office and
commercial uses. Although the indicated parking is four spaces less than the
typical minimum ordinance requirement staff is supportive of the parking as
proposed.
The street buffer has been indicated at 11 -feet 9 -inches narrowing to 9 -feet. The
ordinance typically requires the placement of a 23 -foot street buffer and in no
case less than one-half or 11 -feet 5 -inches. The width of the drive aisle
accessing the western property exceeds the typical design standard and could
be reduced to allow for the typical minimum width of the street buffer. Staff
recommends the drive be reduced to allow the entirety of the street buffer to be
not less than 11 -feet 5 -inches. In addition, staff recommends the applicant
provide a berm and additional plantings at one and one-half times the typical
planting requirement in this area to enhance the landscaped area and minimize
any potential impact of the reduced buffering.
A single ground mounted sign has been indicated on the site plan at the driveway
entrance. The sign is proposed consistent with signage allowed per the Chenal
Design Overlay District or a maximum of eight feet in height and 100 square feet
in area. Building signage is proposed as typically allowed per the zoning
ordinance for commercial building signage or a maximum of ten percent of the
7
FILE NO.: Z -6915-C .(Cont.
fagade area. The applicant is seeking to place the signage on the fronts of the
building as allowed in Section 36-557. According to this section all on -premise
wall signage must face required street frontage except in complexes where a
sign without street frontage would be the only means of identification for a tenant.
The applicant is also seeking a variance from the Land Alteration Ordinance to
allow advanced grading of the site. The applicant is seeking to grade the entire
site with the construction of the sites first building. Staff is supportive of the
request but requests the applicant provide sketch grading and drainage plan
showing areas proposed to be graded and areas not disturbed prior to the
issuance of a building permit.
The site plan includes the placement of a dumpster pad containing two dumpster
receptacles. The hours of service are indicated after 6:00 am. The site is
located adjacent to Rock Creek with the St. Charles Neighborhood to the north
and an apartment development located to the west. To limit the potential
adverse impacts to the adjoining residential uses, staff recommends the
dumpster service hours be limited to daylight hours.
Staff is supportive of the applicants request. The applicant is seeking a rezoning
of the site to allow the site to develop with a mixed use development utilizing 61
percent of the site as office uses. Although the site does not fully comply with the
typical minimum standards for parking and street buffering staff does not feel the
development as proposed will significantly impact the development or the
adjoining properties. To staffs knowledge there are no remaining outstanding
technical issues associated with the request.
STAFF RECOMMENDATIONS:
Staff recommends approval of the request subject to compliance with the
comments and conditions as outlined in paragraphs D, E, F and H of the agenda
staff report.
Staff recommends the applicant increase the street buffer along Chenal Parkway
to a minimum of 11 -feet 5 -inches and include a berm and additional plantings at
one and one half times the typical minimum ordinance requirement.
Staff recommends approval of the variance request from the Land Alteration
Ordinance to allow grading of the area proposed for Phase II with the
development of Phase I.
Staff recommends the dumpster service hours be limited to daylight hours.
PLANNING COMMISSION ACTION- (AUGUST 16, 2007)
The applicant was present. There were no registered objectors present. Staff
presented the item with a recommendation of approval of the request subject to
N.
FILE NO.: Z -6915-C (Cont.
compliance with the comments and conditions as'outlined in paragraphs D, E, F and H
of the agenda staff report. Staff presented a recommendation the street buffer along
Chenal Parkway be increased to a minimum of 11 -feet 5 -inches and include a berm and
additional plantings at one and one half times the typical minimum ordinance
requirement. Staff presented a recommendation of approval of the variance request
from the Land Alteration Ordinance to allow grading of the area proposed for Phase II
with the development of Phase I. Staff also presented a recommendation the dumpster
service hours be limited to daylight hours.
There was no further discussion of the item. The chair entertained a motion for
placement of the item on the consent agenda for approval. The motion carried by a
vote of 7 ayes, 0 noes, 3 absent and 1 open position.
J
August 16, 2007
ITEM NO.: 7
FILE NO.: Z -6915-C
NAME: Gamble Road Short -form PCD and Land Alteration Variance Request
LOCATION: Located on the Northwest corner of Chenal Parkway and Gamble Road
DEVELOPER:
Davis Properties
P.O. Box 241025
Little Rock, AR 72223
CAI!•`IAICCD•
White-Daters and Associates
24 Rahling Circle
Little Rock, AR 72223
A r7)!'`L1ITCf--r-
Terry Burruss, Architects
1202 South Main Street, Suite 230
Little Rock, AR 72202
AREA: 3.22 acres
CURRENT ZONING
NUMBER OF LOTS: 2
PCD
FT. NEW STREET: 0
ALLOWED USES: 0-3, General Office District and C-3, General Commercial
District uses
PROPOSED ZONING: Revised PCD
PROPOSED USE:
0-3, General Office District and C-3, General Commercial
District uses
VARIANCES/WAIVERS REQUESTED: None requested.
BACKGROUND:
A request to rezone the site from 0-3, General Office District to PCD was reviewed and
approved by the Little Rock Planning Commission at their March 8, 2001, Public
August 16, 2007
SUBDIVISION
NO.: 7 (Cont.
FILE NO.: Z -6915-C
Hearing. This applicant requested staff not forward the item to the Board of Directors
for final action therefore the property remained zoned 0-3. The applicant proposed a
three -lot plat to consist of 0-3, General Office District permitted uses and a furniture
store.
The Planning Commission reviewed and approved a request for a preliminary plat of
this site at their May 26, 2005, Public Hearing. The applicant requested the subdivision
of 3.22 acres of 0-3, General Office District zoned property into two lots. The average
lot size proposed was 1.79 acre with Lot 1 being 1.23 acres and Lot 2 being 2.34 acres.
Proposed Lot 1 had street frontage to Chenal Parkway but was not allowed a driveway
access. A cross access and utility easement was approved to serve Lot 1.
Ordinance No. 19,455 adopted by the Little Rock Board of Directors on December 5,
2005, rezoned the site from 0-3, General Office District to PCD and established
Gamble Road Short -form PCD. The rezoning for Lot 2 to PCD allowed the
development of Gamble Road Plaza Center a three-story building with a lower level, a
main level and an upper level. The lower level would be used for office space and
some storage space. The main level was proposed for retail space and the upper level
containing office space.
The site was to be developed with approximately 12,000 square feet of retail space and
19,630 square feet of office space. The development was proposed as 62 percent
office utilizing 0-3, General Office District uses and 38 percent commercial utilizing C-3,
General Commercial District uses. The applicant indicated a furniture store was
proposed to locate on the site along with several office users. The furniture store would
have an area of showroom and display along with an area of warehousing.
The applicant proposed the right of way for Gamble Road be abandoned and access to
Rock Creek Park to the north preserved via an access and utility easement located
within the east 20 -feet of the existing right of way. Access to Lot 1 would be maintained
with an access easement for use of the existing driveway along the east side of Lot 1.
Ordinance No. 19,454 adopted by the Little Rock Board of Directors on December 5,
2005, abandoned the right of way for Gamble Road.
A. PROPOSAUREQUEST:
The applicant is now seeking a rezoning of the site to allow the development of
the site in two phases with a single building constructed in each phase. The first
phase is proposed with the construction of a 6,000 square foot two story building
constructed for an office user. The second building is also proposed as a
two-story building with 20,300 square feet utilizing the ground level as retail and
the upper level as office spaces. The site plan includes 76 on-site parking
spaces to serve the development.
2
August 16, 2007
SUBDIVISIO
ITEM NO.: 7 Cont. FILE NO.: Z -6915-C
The applicant is also seeking a variance from the Land Alteration Ordinance to
allow advanced grading of the site. The applicant is seeking to grade the entire
site with the construction of the sites first building.
B. EXISTING CONDITIONS:
The site contains an existing medical office building taking access from Gamble
Road (previously abandoned). There is an apartment complex located to the
west of the site. To the north of the site is the Rock Creek Floodway; an area
identified on the Parks Master Plan as recreational open space. The area to the
east of the site is zoned PCD and is a strip retail center. South of the site are
commercial uses located on C-3, General Commercial District zoned property.
C. NEIGHBORHOOD COMMENTS:
The Parkway Place Neighborhood Association, the Gibralter Heights
Neighborhood Association along with all property owners located within 200 -feet
of the site and all residents who could be identified located within 300 feet of the
site were notified of the public hearing. As of this writing staff has received one
informational phone call from an area resident.
D. ENGINEERING COMMENTS:
PUBLIC WORKS CONDITIONS:
1. A grading permit in accordance with Section 29-186 (c) and (d) will be
required prior to any land clearing or grading activities at the site. Site
grading, and drainage plans will need to be submitted and approved prior to
the start of construction. If the applicant plans to clear Phase 2 with
construction of Phase 1, a variance from the Land Alteration Regulations
must be requested.
2. A Sketch Grading and Drainage Plan will be required per Section 29-186
(e).
3. Storm water detention ordinance applies to this property. Show the
proposed location for storm water detention facilities on the plan.
4. If disturbed area is one (1) or more acres, obtain a NPDES storm water
permit from the Arkansas Department of Environmental Quality prior to the
start of construction.
5. A special Grading Permit for Flood Hazard Areas will be required per
Section 8-283 prior to construction.
6. Provide existing topographic information at maximum five-foot contour
interval. Show the limits of the 100 -year floodway and floodplain.
7. The minimum Finish Floor elevation is required to be shown on plat and
grading plans.
3
August 16, 2007
UBDIVISION
ITEM NO.: 7
FILE NO.: Z -6915-C
8. The median shown in the site plan is not drawn correctly. The intersection
has 2 thru lanes and a right turn lane.
9. In accordance with Section 31-176, floodway areas must be shown as
floodway easements or be dedicated to the public. In addition, a 25 foot
wide access easement is required adjacent to the floodway boundary.
10. The abandoned right of way must be platted with a 20 foot access
easement to allow access to City owned property for maintenance. The
previous application showed the easement on the eastern side of the
abandoned right of way.
11. The proposed driveway into and out of proposed development must be
redesigned for a straight vehicular movement into and out of the
development and not require vehicles to jog left or right.
E. UTILITIES AND FIRE DEPARTMENT/COUNTY PLANNING:
Wastewater: Sewer available to the site. Sewer service for 13100 Chenal
Parkway may cross property involved in development. If so sewer main will be
required with easement to serve the existing building. Contact Little Rock
Wastewater Utility at 688-1414 for additional information.
Entergy: No comment received.
Center -Point Ener : No comment received.
AT & T: No comment received.
Central Arkansas Water: Contact Central Arkansas Water regarding the size
and location of the water meter. Additional fire hydrant(s) will be required.
Contact the Little Rock Fire Department to obtain information regarding the
required placement of the hydrant(s) and contact Central Arkansas Water
regarding procedures for installation of the hydrant(s). No signs, light poles, flag
poles or other objects with foundations will be allowed within the waterline
easement crossing this property. Extra care must be taken to protect the water
main within this easement.
Fire Department: Place and install fire hydrants per code. Contact the Little
Rock Fire Department for additional information.
County Planning: No comment.
CATA: The site is not located on a dedicated CATA Bus Route.
51
August 16, 2007
SUBDIVISION
ITEM NO.: 7 (Cont.
F. ISSUES/TECHNICAL/DESIGN-
FILE NO.: Z -6915-C
Planning Division: This request is located in the Chenal Planning District. The
Land Use Plan shows Multi Family for this property. The applicant has applied
for a revised Planned Commercial Development to allow construction of two
buildings on the site.
A Land Use Plan Amendment (LU01-19-01) to change this area to Mixed Use
was approved by the Planning Commission for this site on March 8, 2001, but
this amendment was never acted on by the Board of Directors. If the current
zoning item Z -6915-C is approved by the Planning Commission, this Land Use
Plan amendment will go to the Board of Directors along with the zoning item.
Master Street Plan: Chenal Parkway is shown as a Principal Arterial on the
Master Street Plan. This street may require dedication of right-of-way and may
require street improvements. The primary function of a Principal Arterial is to
serve through traffic and to connect major traffic generators or activity centers
within urbanized areas. Entrances and exits should be limited to minimize
negative effects of traffic and pedestrians since this is a Principal Arterial.
Bicycle Plan: A Class I bike route is shown north of this site according to the
Master Street Plan bicycle section. A Class I bikeway is built separate from or
alongside a road. Additional paving and right of way may be required.
Cily Recognized Neighborhood Action Plan: The applicant's property lies in the
area covered by the Rock Creek Neighborhood Action Plan. The Park and
Recreation goal states: "Work with Parks and Recreation to develop open space
behind Target into a passive park system with access from Chenal Parkway
(via Gamble Road) and Markham Street." The Office and Commercial
Development goal states: "Aggressively use Planned Zoning Districts (PZDs) to
influence more neighborhood -friendly and better quality developments."
Landscape:
1. The site plan must comply with the City's minimal landscape and buffer
ordinance requirements.
2. The zoning buffer ordinance requires a twenty-three foot (23') wide land use
buffer along the northern perimeter of the property. Seventy percent of this
area is to remain undisturbed.
3. The zoning buffer ordinance requires a twenty foot wide (20') land use buffer
along the western most portion of the property, next to the residentially zoned
areas. Seventy percent of this area is to remain undisturbed.
5
August 16, 2007
SUBDIVISION
ITEM NO.: 7 (Cont.) FILE NO.: Z -6915-C
4. The zoning buffer ordinance requires a nine foot wide (9') land use buffer
along the western/southern portion of the site, next to the office zoned
property. Seventy percent of this area is to remain undisturbed.
5. The zoning street buffer requires an average twenty-three foot (23') wide
street buffer and in no point be less than half along Chenal Parkway.
6. A six (6) foot high opaque screen, either a wooden fence with its face side
directed outward, a wall, or dense evergreen plantings, is required along the
northern, western, and southern perimeters of the site, where located to areas
that are deemed less intensity uses by the City of Little Rock code. Credit
towards fulfilling this requirement can be given for existing trees and
undergrowth that satisfies this year -around requirement.
7. An automatic irrigation system to water landscaped areas will be required.
8. Prior to the issuance of a building permit, it will be necessary to provide an
approved landscape plan stamped with the seal of a Registered Landscape
Architect.
9. The City Beautiful Commission recommends preserving as many existing
trees as feasible on this site. Credit toward fulfilling Landscape Ordinance
requirements can be given when preserving trees of six (6) inch caliper or
larger.
G. SUBDIVISION COMMITTEE COMMENT:
(July 26, 2007)
The applicant was present. Staff presented an overview of the proposed
development stating there were a number of technical issues associated with the
request remaining outstanding. Staff requested the applicant include a cross
access easement on the site plan to serve Lot 1. Staff also questioned the total
office and total commercial spaces proposed for the site. Staff questioned if the
developers were willing to limit the available square footage for restaurant use.
Staff stated the site was located within the Chenal Design Overlay District which
regulated signage and overhead utilities. Staff questioned the location for the
proposed signage including the total height and area and the total area for the
proposed building signage.
Public Works comments were addressed. Staff stated the driveway into the
proposed development must be realigned to provide straight vehicular movement
into and out of the development. Staff stated the abandoned right of way must
be platted as a 20 foot access easement to access City owned property for
maintenance. Staff questioned if the entire site would be cleared with the
development of Phase I. Staff stated if this was the case a variance from the
Land Alteration Ordinance would be required.
Landscaping comments were addressed. Staff stated a minimum street buffer of
23 -feet would be required along Chenal Parkway. Staff also stated a 20 -foot
0
August 16, 2007
SUBDIVISION
ITEM NO.: 7 (Cont.
FILE NO.: Z -6915-C
land use buffer would be required along the western perimeter and 9 -foot along
the eastern perimeter. Staff stated an automatic irrigation system would be
required to water landscaped areas. Staff stated a landscape plan would be
required prior to the issuance of a building permit.
Staff noted comments from the various other reporting departments and
agencies suggesting the applicant contact them directly for additional information
and clarification. There was no further discussion of the item. The Committee
then forwarded the item to the full Commission for final action.
H. ANALYSIS:
The applicant submitted a revised site plan to staff addressing most of the issues
raised at the July 26, 2007, Subdivision Committee meeting. The revised plan
has not addressed staff's concerns related to vehicular access. Vehicles must
still jog left or right to enter or exit the development creating a traffic hazard.
Staff feels only a minor modification is necessary to remedy this situation and
recommends the entrance be redesigned with the assistance of the City Traffic
Engineer.
The site is proposed for development in two phases with a single building
constructed in each phase. The first phase is proposed with the construction of a
building footprint with 3,000 square feet and the structure being a two story office
building. The second building is proposed as a two story building with a
10,150 square foot building footprint utilizing the ground level as retail and the
upper level as office spaces. The maximum building height proposed is 30 -feet.
The request includes a limit of 20 percent of the gross floor area for a restaurant
user or 2,030 square feet.
The total building square footage proposed for the site is 26,300 square feet with
16,150 square feet designated for office space and 10,150 square feet for
commercial space. The site plan includes 76 on-site parking spaces to serve the
development. Based on typical minimum parking requirements a total of
40 parking spaces would be required to serve the proposed office use and 33 to
serve the commercial space. Based on a portion of the site being used for a
restaurant use 47 parking spaces would be required to serve the commercial
portion of the development or 20 spaces for the restaurant and the remainder to
serve potential commercial users. Based on the maximum intensity of uses a
total of 80 parking spaces would typically be required for the office and
commercial uses. Although the indicated parking is four spaces less than the
typical minimum ordinance requirement staff is supportive of the parking as
proposed.
The street buffer has been indicated at 11 -feet 9 -inches narrowing to 9 -feet. The
ordinance typically requires the placement of a 23 -foot street buffer and in no
case less than one-half or 11 -feet 5 -inches. The width of the drive aisle
7
August 16, 2007
SUBDIVISION
ITEM NO.: 7 (Cont.) FILE NO.: Z -6915-C
accessing the western property exceeds the typical design standard and could
be reduced to allow for the typical minimum width of the street buffer. Staff
recommends the drive be reduced to allow the entirety of the street buffer to be
not less than 11 -feet 5 -inches. In addition, staff recommends the applicant
provide a berm and additional plantings at one and one-half times the typical
planting requirement in this area to enhance the landscaped area and minimize
any potential impact of the reduced buffering.
A single ground mounted sign has been indicated on the site plan at the driveway
entrance. The sign is proposed consistent with signage allowed per the Chenal
Design Overlay District or a maximum of eight feet in height and 100 square feet
in area. Building signage is proposed as typically allowed per the zoning
ordinance for commercial building signage or a maximum of ten percent of the
fagade area. The applicant is seeking to place the signage on the fronts of the
building as allowed in Section 36-557. According to this section all on -premise
wall signage must face required street frontage except in complexes where a
sign without street frontage would be the only means of identification for a tenant.
The applicant is also seeking a variance from the Land Alteration Ordinance to
allow advanced grading of the site. The applicant is seeking to grade the entire
site with the construction of the sites first building. Staff is supportive of the
request but requests the applicant provide sketch grading and drainage plan
showing areas proposed to be graded and areas not disturbed prior to the
issuance of a building permit.
The site plan includes the placement of a dumpster pad containing two dumpster
receptacles. The hours of service are indicated after 6:00 am. The site is
located adjacent to Rock Creek with the St. Charles Neighborhood to the north
and an apartment development located to the west. To limit the potential
adverse impacts to the adjoining residential uses, staff recommends the
dumpster service hours be limited to daylight hours.
Staff is supportive of the applicant's request. The applicant is seeking a rezoning
of the site to allow the site to develop with a mixed use development utilizing 61
percent of the site as office uses. Although the site does not fully comply with the
typical minimum standards for parking and street buffering staff does not feel the
development as proposed will significantly impact the development or the
adjoining properties. To staff's knowledge there are no remaining outstanding
technical issues associated with the request.
AFF RECOMMENDATIONS:
Staff recommends approval of the request subject to compliance with the
comments and conditions as outlined in paragraphs D, E, F and H of the agenda
staff report.
E
August 16, 2007
SUBDIVISION
ITEM NO.. 7 (Cont.) FILE NO.: Z -6915-C
Staff recommends the applicant increase the street buffer along Chenal Parkway
to a minimum of 11 -feet 5 -inches and include a berm and additional plantings at
one and one half times the typical minimum ordinance requirement.
Staff recommends approval of the variance request from the Land Alteration
Ordinance to allow grading of the area proposed for Phase II with the
development of Phase I.
Staff recommends the dumpster service hours be limited to daylight hours.
PLANNING COMMISSION ACTION:
(AUGUST 16, 2007)
The applicant was present. There were no registered objectors present. Staff
presented the item with a recommendation of approval of the request subject to
compliance with the comments and conditions as outlined in paragraphs D, E, F and H
of the agenda staff report. Staff presented a recommendation the street buffer along
Chenal Parkway be increased to a minimum of 11 -feet 5 -inches and include a berm and
additional plantings at one and one half times the typical minimum ordinance
requirement. Staff presented a recommendation of approval of the variance request
from the Land Alteration Ordinance to allow grading of the area proposed for Phase II
with the development of Phase I. Staff also presented a recommendation the dumpster
service hours be limited to daylight hours.
There was no further discussion of the item. The chair entertained a motion for
placement of the item on the consent agenda for approval. The motion carried by a
vote of 7 ayes, 0 noes, 3 absent and 1 open position.
ti�
1202 S NAIN. SUITE 230
LIliLE ROCK, All 72202
501-376-3676 FA}C37&3766
L Architect deSign planning and interiors
August 1, 2007
Mrs. Donna James
Subdivision Administrator
Department of Planning & Development
City of Little Rock
723 W. Markham, 1st Floor
Little Rock, AR 72201
RE: Davis Properties
NW corner of Chenal Parkway and Gamble Road
Little Rock, Arkansas
A/E # 0710
City File # Z -6915-C
Dear Mrs. James:
Following is our response to the Subdivision Committee Comments from July 26, 2007:
Planning Staff Comments:
1. Concur.
2. Concur (access easement in place).
3. Information noted on revised site plan.
4. Information noted on revised site plan.
5. Area for two dumpsters is shown on site plan.
6:00 pm.
Hours of pickup will be after
6. No fencing is proposed. Screening will be accomplished with landscaping.
7. Shown on revised site plan.
8. Shown on revised site plan.
9. Concur.
10. Concur.
Variance and Waivers:
1.
Concur.
2.
Concur.
3. '
Concur.
4.
Concur.
5.
Concur.
6.
Concur.
7.
Concur.
8.
Concur.
9.
Concur.
10. Concur. - f
11. Concur.
12. Driveways are designed to align with existing access.
13. Concur.
Public Works Conditions:
Utilities and Fire Department/County Planning:
Wastewater: Concur.
Entergy: Concur.
Centerpoint Enemy: Concur.
AT&T: Concur.
Central Arkansas Water: Concur.
Fire Department: Concur.
County Planning: Concur.
CATA: Concur.
Planning Division: Concur.
Master Street Plan: Concur.
Bicycle Plan. Concur.
City Recognized
Neighborhood Action Plan: Concur.
Landscape:
1. Concur.
2. Concur.
I Concur.
4. Concur.
5. The parking and drives are established to align with existing. While we not meet this
buffer requirement, we will intensify landscaping and build the access road for the city of
Little Rock.
6. Concur.
7. Concur. Screening will be accompanied with landscaping.
8. Concur.
9. Concur.
10. Concur.
Attached please find four (4) copies of revised site plan. We appreciate your consideration on
this request. If there are any questions or additional information is needed, please call.
Yours very truly,
Terry G. Burruss, AIA
ITEM NO.: 7
Z -6915-C
NAME: Gamble Road Short -form PCD
LOCATION: located on the Northwest corner of Chenal Parkway and Gamble Road
Planninq Staff Comments:
1. Provide notification of property owners located within 200 -feet of the site,
complete with the certified abstract list, notice form with affidavit executed and
proof of mailing. The notice must be mailed no later than August 1, 2007. The
Office of Planning and Development must receive the proof of notice no later
than August 10, 2007.
2. Provide a cross access easements on the proposed site plan to allow access to
indicated Lot 1.
3. Provide the total office and total commercial square footage proposed for the
indicated building on the site plan. Provide the proposed use mix of the
development and the proposed uses. Will there be limits placed on the total
square footage allowed for restaurant spaces.
4. Provide the maximum building height in the general notes section of the
proposed site plan.
5. Will there be more than one dumpster located on the site? If so indicate the
location of the proposed dumpsters along with a note concerning the proposed
screening and a note concerning the proposed hours of dumpster service.
6. Is any fencing proposed as a part of the proposed development? If so indicate
the location of the proposed fencing.
7. Provide details of any proposed signage including height/area and location. The
site does fall within the Chenal Parkway Design Overlay District, which does
regulate signage with a maximum height of eight feet and a maximum square
footage of one hundred square feet.
8. Provide details of the proposed building signage on the site plan.
9. Provide details concerning the proposed parking lot lighting. Parking lot lighting
shall be designed and located in such a manner so as not to disturb the scenic
appearance of the corridor. Lighting will be directed to the parking areas and not
reflected to adjacent parcels. All lighting and other utilities on lots adjacent to
Chenal/Financial Center Parkway which are located in front of the rear line of the
building or in front of the rear line of the building is such lighting and utilities were
constructed prior to building construction, shall be underground. Notwithstanding
the foregoing limitation, no overhead utilities shall be constructed within one
hundred feet of the Chenal/Financial Center Parkway right of way. All site
lighting must be low level and directed downward and into the site.
10. The right of way for Gamble Road was abandoned by the Board of Directors on
December 5, 2005, by the adoption of Ordinance No. 19,454.
Variance/Waivers:
Item # 7.
1. A 20 foot radial dedication of right-of-way is required at the intersection of Chenal
Parkway and Gamble Road.
2. A grading permit in accordance with Section 29-186 (c) and (d) will be required prior
to any land clearing or grading activities at the site. Site grading, and drainage plans
will need to be submitted and approved prior to the start of construction. If the
applicant plans to clear Phase 2 with construction of Phase 1, a variance from the
Land Alteration Regulations must be requested.
3. A Sketch Grading and Drainage Plan will be required per Section 29-186 (e).
4. Storm water detention ordinance applies to this property. Show the proposed
location for storm water detention facilities on the plan.
5. If disturbed area is one (1) or more acres, obtain a NPDES storm water permit from
the Arkansas Department of Environmental Quality prior to the start of construction.
6. A special Grading Permit for Flood Hazard Areas will be required per Section 8-283
prior to construction.
7. Provide existing topographic information at maximum five-foot contour interval.
Show the limits of the 100 -year floodway and floodplain.
8. The minimum Finish Floor elevation is required to be shown on plat and grading
plans.
9. The median shown in the site plan is not drawn correctly. The intersection has 2
thru lanes and a right turn lane.
10.In accordance with Section 31-176, floodway areas must be shown as floodway
easements or be dedicated to the public. In addition, a 25 foot wide access
easement is required adjacent to the floodway boundary.
11. The abandoned right of way must be platted with a 20 foot access easement access
City owned property for maintenance. The previous application showed the
easement on the eastern side of the abandoned right of way.
12. In accordance with Section 31-210 (h)(12), access driveways running parallel to the
street shall not create a four-way intersection within 75 feet of the future curb line of
the street.
13.The proposed driveway into and out of proposed development must be redesigned
for a straight vehicular movement into and out of the development and not require
vehicles to jog left or right.
Public Works Conditions:
Utilities and Fire Department/County Planning:
Wastewater: Sewer available to the site. Sewer service for 13100 Chenal Parkway
may cross property involved in development. If so sewer main will be required with
easement to serve the existing building. Contact Little Rock Wastewater Utility at 688-
1414 for additional information.
Entergy: No comment received.
Center -Point Ener v: No comment received.
AT & T: No comment received.
Item # 7.
Central Arkansas Water: Contact Central Arkansas Water regarding the size and
location of the water meter. Additional fire hydrant(s) will be required. Contact the Little
Rock Fire Department to obtain information regarding the required placement of the
hydrant(s) and contact Central Arkansas Water regarding procedures for installation of
the hydrant(s). No signs, light poles, flag poles or other objects with foundations will be
allowed within the waterline easement crossing this property. Extra care must be taken
to protect the water main within this easement.
Fire Department: Place and install fire hydrants per code. Contact the Little Rock
Fire Department for additional information.
County Planning: No comment.
CATA: The site is not located on a dedicated CATA Bus Route.
Planning Division: This request is located in the Chenal Planning District. The Land
Use Plan shows Multi Family for this property. The applicant has applied for a revised
Planned Commercial Development to allow construction of two buildings on the site.
A Land Use Plan Amendment (LU01-19-01) to change this area to Mixed Use was
approved by the Planning Commission for this site on March 8, 2001, but this
amendment was never acted on by the Board of Directors. If the current zoning item Z-
6915 -C is approved by the Planning Commission, this Land Use Plan amendment will
go to the Board of Directors along with the zoning item.
Master Street Plan: Chenal Parkway is shown as a Principal Arterial on the Master
Street Plan. This street may require dedication of right-of-way and may require street
improvements. The primary function of a Principal Arterial is to serve through traffic and
to connect major traffic generators or activity centers within urbanized areas. Entrances
and exits should be limited to minimize negative effects of traffic and pedestrians since
this is a Principal Arterial.
Bicycle Plan: A Class I bike route is shown north of this site according to the Master
Street Plan bicycle section. A Class I bikeway is built separate from or alongside a road.
Additional paving and right of way may be required.
City Recognized Neighborhood Action Plan: The applicant's property lies in the area
covered by the Rock Creek Neighborhood Action Plan. The Park and Recreation goal
states: "Work with Parks and Recreation to develop open space behind Target into a
passive park system with access from Chenal Parkway (via Gamble Road) and
Markham Street." The Office and Commercial Development goal states: "Aggressively
use Planned Zoning Districts (PZDs) to influence more neighborhood -friendly and better
quality developments."
Landscape:
1. The site plan must comply with the City's minimal landscape and buffer ordinance
requirements.
Item # 7.
2. The zoning buffer ordinance requires a twenty-three foot (23') wide land use buffer
along the northern perimeter of the property. Seventy percent of this area is to
remain undisturbed. '
3. The zoning buffer ordinance requires a twenty foot wide (20') land use buffer along
the western most portion of the property, next to the residentially zoned areas.
Seventy percent of this area is to remain undisturbed.
4. The zoning buffer ordinance requires a nine foot wide (9') land use buffer along the
western/southern portion of the site, next to the office zoned property. Seventy
percent of this area is to remain undisturbed.
5. The zoning street buffer requires an average twenty-three foot (23') wide street
buffer and in no point be less than half along Chenal Parkway. Currently, this site is
not meeting this minimal distance. It appears the parking and building can be shifted
north to help meet this minimal amount.
6. Is the proposed road located within a cross access easement area and if so, please
delineate on the plan as such.
7. A six (6) foot high opaque screen, either a wooden fence with its face side directed
outward, a wall, or dense evergreen plantings, is required along the northern,
western, and southern perimeters of the site, where located to areas that are
deemed less intensity uses by the City of Little Rock code. Credit towards fulfilling
this requirement can be given for existing trees and undergrowth that satisfies this
year -around requirement.
8. An automatic irrigation system to water landscaped areas will be required.
9. Prior to the issuance of a building permit, it will be necessary to provide an approved
landscape plan stamped with the seal of a Registered Landscape Architect.
10.The City Beautiful Commission recommends preserving as many existing trees as
feasible on this site. Credit toward fulfilling Landscape Ordinance requirements can
be given when preserving trees of six (6) inch caliper or larger.
Revised plat/lan: Submit four (4) copies of a revised preliminary plat (to include the
additional information as noted above) to staff on Wednesday, August 1, 2007.
Item # 7.